| Sl. No. | Item Description |
| 1 | Name of Work :- Renovation and upgradation of the Guest house on the 11th floor of Zerlina Building Malabar Hills under LGR Maintenance unit, Mumbai NIT No. :- DCSEM/CQD/QSB/26-27/NIT/05 dt.29.04.2026 |
| 2 | The site is situated at Zerlina Building, Little Gibbs Road, Malabar hill, Mumbai. |
| 3 | The tenderers are advised to visit the site of work & its surroundings, with prior permission of Engineer-in-charge/authorised representative, to acquaint themselves about the location of work, accessibility to the site, level of sub-soil water, drainage facility for dewatering and any other matter relating to availability and carriage of construction materials, nature of work etc., and satisfy themself and then quote the rates accordingly. A Tenderer shall be deemed to have full knowledge of the site whether he inspects it or not and NO extra charges consequent on any misunderstanding or otherwise shall be allowed. |
| 4 | Tenderers shall visit the site of work, at their own cost. The request email for site visit shall be sent well in advance (preferably three working days before) for preparation of visitor pass, fixing suitable & mutually agreed date & time for site visit. The email ID for site visit is mentioned in tender documents. |
| 5 | Contractor is fully responsible for making payment of Minimum wages & Bonus to labourers, EPF & ESI to statutory Authorities timely and submission of challans and documentary proof to EIC for release of payment of Running Account / Final Bill. Otherwise, bill will not be forwarded by EIC to Accounts for payment. EIC should ensure that all necessary documents are submitted by Agency for release of payment. No Running Account / Final Bill shall be paid for the work till the applicable labour license, registration and challans with EPFO, ESIC and BOCW (Building and Other Construction Workers) Welfare Board, whatever applicable, are submitted by the Contractor to the Engineer-in-Charge.) |
| 6 | Contractor shall take a Contractor’s All Risk (CAR) Insurance Policy in respect of entire scope of work and a Janata insurance policy to cover the compensation claims arising out of Workmen's Compensation Act-1923. The Insurance policy shall be taken for entire period of contract and copy of the same shall be submitted to the Engineer-in-Charge before commencement of the work. The insurance policy shall be taken before commencement of the work and shall be renewed during the construction period till actual completion of work. The charges for issue & renewal of insurance policy shall be borne by Contractor. In event of failure of the Contractor to obtain Insurance Policy, Running Account Payments of the Contractor shall not be released till such time the same is obtained by the Contractor & submitted to the Engineer-in-Charge. In case, Insurance Policy has validity period not matching with contract period (either due to policy start date later than actual date of start of work or policy end date earlier than actual date of completion), then penalty for gap in period shall be levied at one and half times the rate of Insurance Policy premium including GST, to be computed on per day basis. All the workers engaged on the work shall required to be insured as per Government norms at the cost of contractor. |
| 7 | The Contractor shall submit with every Running Account / Final Bill, a certificate of employment/deployment of the Technical representative(s) as per Clause 36 (i) in Schedule 'F' of \\" Salient Governing Features of the Tender\\", after certifying by Engineer-in-Charge. In the event of not fulfilling the above provisions of Clause 36(i), recovery shall be made from the contractor as per Schedule 'F'. |
| 8 | Arrangement of Electricity : as per Schedule -BElectricity for construction work will be supplied by department @ free of cost. |
| 9 | Arrangement of Water : as per Schedule -BWater will be supplied by department and water charges will be recovered @1% of gross value of work done. |
| 10 | The drawings issued for Tender purpose are preliminary and indicative only. The Working drawings as applicable shall be issued in phased manner at the time of execution. Nothing extra shall be entertained towards revision in drawings. Drawing shall not be taken outside campus/site/premises without Gate Pass issued by EIC. |
| 11 | All the items of sub-structure include the cost of dewatering and shoring, wherever necessary, during the progress of work, till its completion without any extra cost to the Department. |
| 12 | The Schedule of Quantities include contingent works for other services (PHE, Electrical, Mechanical etc.) which shall be paid under relevant Civil items. Accordingly, the Contractor shall carry out all related works such as making cut outs, nitches, pipe sleeves, foundation pockets for embedded plate, bolts, parts etc. in concrete/ brick works as and when required by Engineer-in-charge without any extra cost to the Department. |
| 13 | PPC/ Blended cement of recommended brand shall only be used for all masonry and finishing works unless noted otherwise. Only Fully treated dry, well graded sand conforming to IS 383 shall be used. |
| 14 | Only Ready Mix Mortar of approved make shall be used. The ready mix mortar shall be manufactured by preferred manufacturers, using cement-sand in required proportion. |
| 15 | The size and thickness of natural stones/ tiles mentioned for flooring dado, skirting etc. are approximate and subject to the availability in market during execution. If the required size and thickness is not available, the next higher size and thickness of tiles/ stones shall be used without any extra cost to the Department. The contractor may quote the rates accordingly. |
| 16 | Quoted rate shall hold good for plain/ curved/ any other geometric shapes & sizes of all structural/ RCC members including formworks, masonry, flooring, doors & windows, plastering, painting etc. at all leads, levels, lifts and floors including scaffolding, bracing, multilevel staging etc., unless noted otherwise. Nothing extra shall be entertained towards wastages of materials, additional labours/ tools & plants etc. to achieve the required shapes & sizes etc. |
| 17 | The Contractor shall follow the DAE safety rules strictly. All safety & security regulations shall be followed strictly as per specifications & conditions of contract. |
| 18 | The following Security regulations shall be followed strictly while movement of labourers/ workers/ contractor's personnel including transportation of the materials etc. i) The Workers, Engineers and Supervisors will be provided vigil passes (for entry into Premises) on submission of application forms in prescribed formats supported by documentary proof like Aadhar card, Voter ID card and Ration Card / Driving Licence / PAN card etc. Police Verification Certificate (PVC) is mandatory for Engineers and Supervisors (wherever desired by department). You are requested to obtain immediately Police Verification Certificate (PVC) of your regular staff deployed at site(s) in respect of works and submit the same along with necessary application to allow them to enter in premises to carry out the assigned work. ii) The Contractor shall obtain special permission for working on extended hours of working days including Saturday, Sunday and holidays etc. iii) Workers shall be escorted from the main gate of campus/premises upto the site by designated supervisors of the contractor and they are not allowed to roam around inside the premises. iv) Transport vehicles of the contractor are allowed to enter the premises for transportation of construction materials. Drivers must have valid driving license of Heavy Vehicle. v) The following Security regulations shall also be followed strictly while movement of labourers/ workers/ contractor's personnel etc. (a) The Contractor shall issue I-Cards to his workers deployed on regular basis. (b) The Supervisor of the contractor having photo pass can bring daily wage workers/ casual workers inside campus for work. He should prepare list of such workers in duplicate. The original copy shall be handed over to the representative of the Engineer-In-Charge at the gate and endorsement obtained on duplicate copy on daily basis. (c) The Contractor's personnel including daily wage workers shall be in uniform with proper identification for ease in identification of such persons at unauthorised places. (d) The daily wage workers/ casual workers employed by the contractor must wear florescence vis-a-vis wear without fail during their presence inside Campus/premises. The contractor shall provide a sleeveless Jacket to the workers in pattern, colour showing name of contractor with address and telephone number as approved by the Engineer-in-charge. All the workers must wear the same while on duty. (e) The Contractor's personnel shall follow all safety rules & security procedure that are in vogue and applicable during execution of work. Contractor shall verify the character and antecedents of the labourers employed, through local address proof issued by competent authorities such as Aadhar card, Voter ID card and ration card / driving license /electricity bills /telephone bill /gas connection document etc. The nationality of contract labourers also needs due verification. |
| 19 | Vehicular movement shall abide by the regulations imposed by the concerned authorities. The contractor shall abide by the security rules & regulations of the Department. The approach roads should be kept clean & free from obstruction for smooth functioning of existing traffic and damages caused, if any, to be made good without any extra cost to the department. Contractor may make provision for entry of vehicles by providing alternate road/ route for entry & exit during the construction work, if required, at his own cost without extra cost to the department. |
| 20 | While transporting materials from site and disposal of surplus materials, the spilled over materials/ earth/ debris etc. on the road should be got cleaned by the contractor after the day's work is over. |
| 21 | Royalty for excavation, transportation, filling of earthwork etc. including obtaining permission from Statutory authority, if any, shall be borne by the contractor. |
| 22 | Regarding disposal of Construction waste from site of work, the agency has to abide by the guidelines of Construction and Demolition (C&D) waste management plan as approved by BMC/Local Municipal Authority and any other regulations issued by Statutory authorities in the matter from time to time and Department is not responsible in any way in this regard. i) Contractor shall strictly follow the Statutory rules and regulations of the Construction and Demolition Debris Management Plan for project site. ii) Surplus Excavated materials and construction debris shall be disposed from construction site at approved disposal ground of BMC/Local Municipal Authority including cost of necessary Statutory charges, as applicable. iii) Contractor shall submit acknowledgement of challan for each trip for unloading of Construction and Demolition waste material as per the standard format. iv) Contractor shall be responsible and liable for penalty, if any, as prescribed by the Local Authority in case of non-fulfilment of the procedure laid down in the Construction and Demolition Debris Management Plan. v) Contractor shall submit irrevocable Bank Guarantee for the amount as insisted by BMC/Local Municipal Authority for the purpose of ensuing compliance of the Waste Management Plan/Debris Management Plan approved by the Local Municipal Corporation from time to time, till the grant /issuance of the Occupation Certificate and charges for same will be borne by Contractor. NOC from C&D Waste Management Department of BMC/Local Municipal Authority shall be submitted by the agency. |
| 23 | Agency should pay necessary charges to BMC/Local Municipal Authority to get done periodical pest control / anti-larva treatment / Insecticide treatment at Construction site. After the completion of work, necessary NOC shall be obtained from BMC /Local Municipal Authority and shall be submitted to Department. The charges for same will be borne by Contractor. |
| 24 | The Agency shall take care of existing services and other department properties while carrying out job. All dismantling, demolishing and excavation work shall be done with most careful manner and with prior written approval of the Engineer-in-charge, without damaging the existing structures, services, finishes, etc. Agency shall take all precautions to cover all furniture, fixtures, glass and window panes to prevent damage. Damage, if any shall be repaired/replaced by agency at his own cost. |
| 25 | Protection of work: The Contractor shall be responsible for the protection of the work during progress. He shall also provide and maintain any other temporary substitute and material for this purpose. He shall take all the necessary precautions to prevent damage to all the works till its handing over. |
| 26 | Wherever old material/works are replaced with new one, quoted rate includes removing/dismantling the existing one and depositing the serviceable material at departmental store and disposing off debris outside the campus/ premises/ colony. |
| 27 | Since the work has to be carried out inside/ near occupied residential/office building, the work shall be executed with least disturbance to occupants of buildings. |
| 28 | Approved Samples of Materials: The Contractor shall submit samples of all materials to be incorporated in the work, without any extra cost to Department, at least 30 days before he places bulk order for the materials and shall obtain approval of samples in writing from the Engineer-In-charge. |
| 29 | Shop drawings for Aluminium work, Structural steel, Stainless steel, Structural glazing, ACP cladding, etc. shall be submitted by Contractor for the approval of Engineer-in-Charge, at least 30 days in advance prior to taking of work. |
| 30 | No labour shall be permitted to stay inside campus/premises/site. |
| 31 | Suitable area near site of work shall be allocated to the contractor for storing construction materials, for site office etc. Optimum care shall be taken by the contractor to avoid disturbing the traffic and road around the building etc. The contractor shall have to maintain proper co-ordination with the fellow agencies working simultaneously in the vicinity of subject work in order to avoid delays in any of the works going on in and around the premises. |
| 32 | Guidelines for Air Pollution mitigation(i) The charges for the Air Pollution mitigation measures shall be borne by the contractor without any extra cost to the department.(ii) Contractor shall follow the directions for Dust and Pollution Control measures in construction as notified by MoEF&CC / MoHUA / CPWD / BMC or any other statutory authority.(iii) All precautionary measures for control of Air Pollution due to Building Construction Activity shall be taken as per Local Statutory/ Municipal Authority Air Pollution Mitigation Plan. (iv) Mandatory Form for Building Construction activity to control Air Pollution along with supporting documents and site photographs shall be submitted to concerened authority or uploaded on online portal.(v) Projects attracting Environmental Clearance shall carry out Third Party Ambient Air Monitoring every fortnightly from NABL / MoEF&CC laboratory. (vi) Construction projects shall mandatorily install sensor-based air quality monitor for measuring PM concentration (PM2.5 and PM10), relative humidity, temperature and display real time AQI data through LED display board (width 1220mm x height 915mm, screen resolution 320 x 192 pixel) at the construction site. Further, installation must be completed within 15 days of issue of Work order or commencement of work. The Contractor shall submit a certificate for completion of installation of air quality monitor and LED display board, after certifying by Engineer-In-charge, along with 1st RA bill for releasing the payment.(vii) The air quality data must be accessible at the site and made available for inspection by Local Municipal Authority/ Competent Authority.(viii) Construction layouts having area more than 01 (one) acre or Height more than 70m, shall have continuous dust or wind breaking tin / metal sheet erected of minimum height 35 feet around periphery of the construction project site and for construction site, less than 01 (one) acre, the tin / metal sheet height shall be 25 feet minimum.(ix) Tarpaulin / Green cloth / Jute sheet to be mandatorily used to cover the floor where any construction activity is in progress and two floors below it and also on scaffolding covering an entire area under demolition structure. Further, regular cleaning of Tarpaulin / Jute sheet to be undertaken. (x) Water sprinkling shall be continuously carried out so that the debris shall remain in wet condition.(xii) All vehicles carrying construction materials/waste/debris shall have valid PUC certificates and the same shall be produced as when asked for by competent authorities.(xiii) Construction workers should mandatorily use PPE (Personal Protective Equipment) i.e. Mask, Goggles etc. |
| 33 | The quoted rate shall be inclusive of providing and erecting temporary barricading of height as per above 'Guidelines for Air Pollution mitigation' (but minimum 10 feet height) using structural steel (MS Pipes or angle iron frame work etc.), covered with tin / GI sheets of approved colour & shade, Struts, MS Clamps, Bracing etc. and shall have wicket gate & material gate and including writing and painting of direction & instructions, providing glow lamps, reflective signs, marking, flags, caution tape etc. Prior written approval of Engineer-in-Charge of the sketch/ drawing showing details of barricading shall be obtained by the contractor. The barricading shall be provided and retained in position at site continuously during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour, materials, equipments and works required to execute the job such as earth work, concrete, welding etc. After completion of work, Contractor shall remove and take away the barricading at his own cost with the prior approval of Engineer-In-Charge. The entire work shall be executed as per direction of Engineer-In-Charge. No work shall be allowed unless the barricading is completed to the satisfaction of the Engineer-in-Charge. The Contractor shall submit a certificate for completion of barricading along with 1st RA bill after certifying by Engineer-in-Charge for releasing the payment. |
| 34 | The contractor shall display proper information/cautionary signage boards at site for the safety of the workers and public in general in the surrounding areas. |
| 35 | Contractor has to provide sign board at site with detailed name of project, name of client, name with contact number of contractor and minimum wages category wise at entrance of project/site without any extra cost to the department. |
| 36 | Guidelines for Scaffolding works - Quoted rates shall include all scaffolding works without any extra cost to the department.(i) Design of scaffolding for carrying out work shall be as per relevant IS Codes & specification. The contractor has to observe all safety procedure while working on heights as per IS: 3696 (Part-I) (Safety Code for Scaffolds). (ii) All working platform must be of minimum 600 mm wide, made of M.S pipe and must have guard rails as per specification. Further, Overhead protection should be provided on the scaffolds to protect workers on lower platform against falling objects from higher level.(iii) Necessary ladder shall be provided at required locations to enable Departmental Staff for supervision of works.(iv) Labours working on the scaffolding should be with safety belts, helmets, goggles and other safety gears.(v) Horizontal Safety Net : Nylon net with a mesh size of 25mm shall be provided at 4.0 meter height from the ground level around the buildings upto a distance of minimum 3.0 meter from the edge of the building on all sides to catch any falling objects.(vi) Vertical Safety Net: Green cloth net shall be provided to the full height of scaffolding / building and securely tied to protect falling material coming out during the progress of work. |
| 37 | Maintaining L1 position During execution of the contract, if tender structure changes due to variation in quantities (i.e Work order quantities, Substituted items quantities including quantities within deviation limit specified in Clause 12 of Schedule ‘F’ in “Salient Governing Features of the Tender”), Contractor has to give suitable discount to remain in L1 position. |
| 38 | The quoted rates shall be inclusive of wastage of labour & material, installation, testing, commissioning, transportation, loading, unloading, lifting etc. and also includes provision of all necessary manpower, tools, machinery, equipment, hoists etc. for carrying out the work in effective manner as per specifications and as directed by Engineer-In-Charge. |
| 39 | The quoted rates shall be inclusive of all Taxes, GST, Cess, Levy, duty etc. |
| 40 | Refer Prebid clarifications, minutes of meeting & corrigendum for revisions, if any, for updates. |
| 41 | No debris shall be left over during the repair works under each item on any day. An area for 'Debris bins' will be identified on the request of contractor for collection of debris generated on day to day basis. The debris from debris bin shall be cleared every week. The contractor must maintain adequate number of wheel barrows all the time for shifting the debris to Debris bin. Penal recovery for not disposing off the debris in time will be made @ Rs.500/- per Cu.M. Name of Work :- Renovation and upgradation of the Guest house on the 11th floor of Zerlina Building Malabar Hills under LGR Maintenance unit, Mumbai NIT No. :- DCSEM/CQD/QSB/26-27/NIT/05 dt.29.04.2026 Item No. Description BoQ4/328 Aluminum Work Note : 1. The contractor shall submit 6 copies of shop drawings for each windows, ventilators showing dimension details of construction etc for approval of the Engineer-in-charge and according to the approved shop drawing a sample of each of windows with all fittings and fixtures with locking arrangement including glass panes etc complete as per schedule of quantities, specifications and drawings, shop drawing should be submitted for preliminary inspection for approval. After preliminary inspection, the sample should be fixed at site to ascertain its performance. Large scale manufacturing should be taken up only after rectification of defects in samples as directed to the full satisfaction of the department and after obtaining formal approval.2. All doors, windows, ventilators section shall be anodised extruded section of M/s. Jindal /M/s Indal or equivalent approved manufacture.3. All fittings / fixtures shall be of approved make / quality and as approved by Architect.4. All dimensions mentioned in the drawing are approximate. Necessary allowance for fixing over rough ground and also necessary allowances for fixing tolerances to be considered while manufacturing. While manufacturing, actual site measurement shall be considered. Necessary planing for fixing the unit has to be carried out by the contractor without any extra cost to the department. However, rate quoted by the contractor shall hold good. 5. Payment shall be made per Kg basis. Aluminium sections such as shutter frames, track window / door frame/ beading channel for glass adjustable louvers etc, shall only be measured linearly as per actual / finished cutting size nearest to centimetre and multiplied with sectional weight of the individual section and the total quantity of aluminium section will be arrived at for payment without any allowance for wastage.The quoted rate shall include cost of cleat angles, fixures etc. 6. All glass panes shall be of approved manufacturer. The glasses will be measured for payment separately under relevant item. Actual size of the glass fixed in position will be considered for payment. 7. Glass panes shall be fixed with approved EPDM gasketting, beading, to be free from settling. Necessary mastic to be provided against seepage of rain water.8. All top hung/side hung shutters to be provided with approved quality friction hinges. All sliding shutters shall be provided with bottom sliding rollers.9. In case of damage of any existing work, the same has to be made good/ restored to original condition by the contractor at his own cost.10. No separate payment shall be made for fittings such as locking arrangement, hinges, friction hinges, rollers, fittings and fixtures, gasket, cleat angle etc. Tenderer are required to consider the cost of these items while quoting the rate for unit weight of aluminium sections for window / door etc.11. However floor spring, hydraulic doorcloser, door plate and handles will be paid seperately under relavent item.12. Approval of the department for the complete design and shop drawing shall be obtained before commencement of the work. |
| 42 | ABSTRACT OF COST |
| 43 | PART -A CIVIL WORKS |
| 44 | PART-B: PH WORKS |
| 45 | PART-C :FURNITURE (UPGRADATION) WORKS |
| 46 | PART: D- ELECTRICAL & AC WORKS |
| 47 | PART -A CIVIL WORKS |
| 48 | Brick masonry work using well burnt bricks from approved lot of class designation 3.5 (classification as per IS:1077-1992 and min. average compression strength not less than 3.5 using ready mix mortar (1.4), (as specified), to correct line, level and plumb including raking out joints, curing, scaffolding all as per specifications, drawings and as directed by Engineer in charge. 1) The contractor shall get approved the samples of bricks / AAC block from the Engineer-In-Charge before procurement on large scale and shall maintain the same for the entire work.2) Necessary Openings/ nitches/ pipe sleeves/ cut-outs, wherever required as per drawings and asked for by the Engineer-In-Charge, shall be provided by the contractor without any extra cost.3) One masonry wall thickness shall be considered as 230 mm and half brick wall as 115mm and lesser wall thickness if any shall be made up to the required dimensions by the contractor in cement mortar 1:4 to proper line, level and plumb without any extra cost to the Department.4) The rate shall include cost of making brick / AAC block masonry to all geometrical shapes and sizes without any extra cost to the Department. |
| 49 | In super structure at all floors, levels & locations |
| 50 | Providing and laying in position, at all floors and at all levels & locations plain cement concrete of grade as specified below including machine mixing, consolidation, finishing, curing and including cost of form work, shuttering, centering etc. complete all as per specifications and directed by EIC. (Note:- Reinforcement provided if any shall be measured & paid under relevant item.) |
| 51 | Cement concrete of 1:2:4 (1 cement, 2 crushed sand, 4 graded stone aggregate of nominal size 20 mm) |
| 52 | Waterproofing work i) The contractor shall get written approval from the Engineer in Charge, for the water proofing agency engaged and shall submit the specification of the waterproofing before commencement of work.ii) The contractor shall test the surface where water proofing treatment provided for bone dry condition by filling up with water for 7 days. No wet patches or leaks shall appear on the surrounding wall or under side of the slab.iii) The contractor shall furnish guarantee bond on appropriate stamp paper in the proforma as per relevant section of Conditions and Clauses of Contract for the entire waterproofing treatment for maintaining the surroundings and under side surfaces of the waterproofing treated area in bone dry condition for 5 years. During the guarantee period the contractor shall attend all leakages, defects etc. if noticed, free of cost, starting the work of checking up and rectification within a week's time from the date of intimation about such leakages/defects. |
| 53 | Filling in bath, W/C, toilet, depressed areas with water proofing brick bat coba of the agency approved by the department at all floors, levels and locations upto the required level and making the surface finished suitable to receive floor finish, including finishing, curing, compaction etc all complete as per drawings and water proofing agency's specifications & as directed by the Engineer-in charge. ( Note:- The generally brick bat coba consist of broken brick bats of size 25 mm to 115 mm with 50% of Cement Mortar (1:4) using Ready mix Cement mortar (as specified) admixed with approved water proofing compound conforming to IS:2645 as per manufacturer's specifications) |
| 54 | Providing & laying at all floors & locations Homogeneous Full body Vitrified tile/ Glazed vitrified tile/ Anti Skid Vitrified tile Vitrified tile double charge/ multi charge (Glossy/Matt/Satin)/Dolce vita of Ispira or equivalant approved manufacturers of sizes 600mm X 600mm / 800mm X 800mm / 1000mm X 1000mm/1200 X 2400mm size or as per approved size and having mimimum thickness 8.5 mm or as specified by approved manufacturer tiles conforming to IS:15622 having water absorption less than or equal to 0.08% (Group B I a), in flooring/skirting/ dado/ cladding/staircase tread/ riser at all floors and location, heights/ levels and lead in approved pattern and colour, shade laid over cement mortar bedding/ backing/ adhesive backing, including cleaning and preparing the surface for bedding/backing, spreading the neat cement slurry, close jointed and grouted with matching coloured readymade cement grout and approved pigment as per manufacturer's specifications, finished to level, line, slope and plumb, cutting of tiles, wastage, making openings/ cut out if neccesary, final cleaning of surfaces,curing etc. all as per drawings, specifications & as directed by Engineer in charge.Note:- The tiles must be cut with the water jet/ zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 55 | In flooring of bedroom using Homogeneous Full body vitrified tile of size 1200 mm X 2400 mm laid over 20 mm thick cement mortar1:4 bedding (using ready mix mortar) and spreading neat cement slurry by using minimum cement about 2 kg/sqm prior to bedding and spreading cement paste using minimum cement of about 4.50 kg/sqm over bedding, |
| 56 | In flooring of bathroom using Homogeneous Full body vitrified anti skid tile of size 600 mm x 600 mm or specified by architect laid over 20 mm thick cement mortar 1:4 bedding (using reday mix mortar) and spreading neat cement slurry by using minimum cement about 2 kg/sqm prior to bedding and spreading cement paste using minimum cement of about 4.50 kg/sqm over bedding, . |
| 57 | In dado of bathroom using Homogeneous Full body vitrified tiles measuring 1200 mm x 600 mm or specified by architect for bathroom walls. Installation includes applying a strong adhesive, ensuring even grout lines, and achieving a clean and level surface. |
| 58 | Supply and installation of following golden tee patti/square bar used for vertical and horizontal tile joints of toilet. The patti should be made from high-quality brass or a similar durable material with a golden finish. Installation includes accurate cutting, fixing at joints, and ensuring the patti is flush and polished for a neat edge as per drawings and as directed by Engineer-in-Charge |
| 59 | 8 mm Square brass bars |
| 60 | Brass ‘T’ section of size 15 mm X 9 mm & 2 mm thick lacquer finished with golden shade used between joint of tiles vertically / horizontally at toilet flooring / dado etc. |
| 61 | Supply and installation of high-quality composite marble of specta Quartz surfaces of Gold rush colour/Cat. No. PL-191 for window sills and jambs. The marble should be polished and precisely cut to fit the designated areas. Installation involves setting the marble using a high-bond adhesive, ensuring perfect alignment, and finishing with matching caulk to create a seamless look as per drawings and as directed by Engineer-in-Charge |
| 62 | Supply and installation of high-quality Plaster of Paris (POP)/PVC moulding for decorative purposes. The moulding should feature intricate designs and be expertly installed on walls and ceilings. This includes preparation of the surface, precise installation of the moulding, and painting to match the interior décor etc. all as per drawings and as directed by Engineer-in-Charge |
| 63 | Providing and fixing in position suspended false ceiling system using 12 mm thick calcium silicate boards (M/s. Hilux Ceiling Systems), 100% humidity resistance, non combustible as per BS476 part IV with thermal conductivity of 0.043 w/m KC placed in a suspended grid of size of 600x 600mm made of hot-dipped G.I steel sections wherein the ceiling sections of 0.55 mm thick shall be suspended at 1200 mm centres along the length of ceiling with 4mm dia G.I wires/ 1 mm thick strip hangers made of G.I sheet sections with necessary level adjusters and inter channels of 0.90 mm thick with connecting clips and resting on the perifery walls on wall angles of 0.55 mm thickness including providing necessary openings for light fixtures, diffusers, trap doors etc to be made as per layout drawings and as per directions of Engineer-in-charge. The main tees to be suspended from the ceiling/ soffit with the help of metal dash fastners of 6mmx50mm, soffit clits of 25mmx35mmx1.60mm and 4mm dia G.I wire with galvanised spring steel levelling clips/ G.I strip Hangers at 600mm centers . the entire grid system shall be designed to bear a distributed load of minimum 25 kg/Sqm (Only calcium silicate false ceiling area will be measured for the purpose of payment) etc.all as per drawings and as directed by Engineer-in-Charge |
| 64 | Repainting of old painted surfaces with two coats of Royal Aspira paint of Asian paint or equivalent of approved shade and make over two coats of approved cement primer which consist of thoroughly scrapping old painted surface, applying a coat of approved cement primer, filling up the cracks with approved crack filling compound, applying stucco putty to entire surface to fill up crevices, mild depression etc. thoroughly scrapping the surface, applying 2 coat of approved cement primer, carrying out putty work wherever required including necessary covering material and removal of splashing's & droppings from floors, walls including scaffolding, ladder as required etc. complete all as directed by the Engineer- in- Charge. |
| 65 | Repainting of old painted surfaces with Calcecruda fuso hexagon subway textured High lighter paint of Asian paint or equivalent & Calcecruda Baroque Lace or metalic bandhej of approved shade and make over two coats of approved cement primer which consist of thoroughly scrapping old painted surface, applying a coat of approved cement primer, filling up the cracks with approved crack filling compound, applying stucco putty to entire surface to fill up crevices, mild depression etc. thoroughly scrapping the surface, applying 2 coat of approved cement primer, carrying out putty work wherever required including necessary covering material and removal of splashing's & droppings from floors, walls including scaffolding, ladder as required etc. complete all as directed by the Engineer- in- Charge. |
| 66 | Providing and applying 1.5 mm thick white cement based wall care putty in two coats of approved make, at all floors, levels and locations, over plastered surfaces finished smooth to correct line, level, plane, plumb etc., including preparing the surfaces, scaffolding smoothen the putty surfaces with very fine water proof emery paper to get a glossy finish etc. complete as per specifications, as per manufacturers specifications, drawing & as directed by the Engineer-in-charge. |
| 67 | Dismantling / demolishing work by manual /Chiselling/ mechnical means, carefully without damaging & disturbing adjacent structures, at all levels, locations & floors including labour, machine, loading, unloading, transportation, scaffolding, stacking of serviceable material at directed place & disposal of unserviceable/debris material to MCGM dumping ground/yard, etc. complete all as per specifications and as directed by Engineer-in-Charge. |
| 68 | Brick masonry work in cement mortar including cement mortar plastering / pointing work |
| 69 | Plain Cement Concrete (PCC), Brickbat coba,Floor tiles etc |
| 70 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground outside colony / campus etc complete all as per specifications and as directed by the Engineer-in Charge. |
| 71 | Providing water proof plastering work of thickness as mentioned below, in using cement sand mortar (1:4) or using ready mix cement mortar having cement : sand (1:4) at all floors, levels & locations, in single coat finished smooth with a floating coat of neat cement including approved water proofing compound added @ 2% by weight of cement or as per manufacturer's specifications in correct line, level, plane, plumb and including scaffolding, curing etc complete all as per specifications and as directed by EIC. (inside trench/nalla/pit / storm water drains etc.)Using ready mix cement mortar having Cement : Sand (1:4) |
| 72 | 12 mm thick |
| 73 | 15 mm thick |
| 74 | 20 mm thick |
| 75 | PART-B: PH WORKS |
| 76 | Providing and fixing in position following Vitreous China Wall Hung type Wash down pattern water Closet consisting following items of work:-i) Providing Vitreous China wall hung type wash down pattern Water Closet ( EWC ) conforming to IS 2556 (part XVI) with integral \\"P\\" trap outlet with water seal not less than 50 mm with vent and necessary C.I. brackets supports.ii) Providing thermosetting or thermoplastic Seat & cover conforming to IS 2548, fixing seat & cover for water closet as per manufacturer's specification including the cost of corrosion resistant hinges, bolts, nuts, non ferrous or S.S washer etc. all complete.iii) Fixing the Water closet in position, jointing the trap, water closet and CI/UPVC pipe by Epoxy grout or Rubber seal as per pipe manufacturer.iv) Cutting hole, making grove or chases in the wall, floors, slabs etc., reinstating to it's original condition after completion of work, painting all metallic parts with two coats of flat oil paint of approved make & shade over a coat of primer, finishing the gaps with white / matching colour cement etc. all complete.v) Testing the system to the full satisfaction of the Engineer-in-Charge. |
| 77 | Vitreous China European Extended wall mount Water Closet of Carlton Glitz French Gold with slow falling seat cover of CERA or equivalent |
| 78 | Providing and fixing concealed type dual flush tank (PVC/HDPE/UPVC) suitable for European type water closet, with dual flushing mechanism (3 litres / 6 litres), including all necessary fittings such as flush bend, inlet pipe, outlet pipe, flush plate with dual actuator, fixing accessories, brackets, and connections with CP brass stop cock and approved CPVC/PVC pipes, cutting and making good the walls wherever required, complete as directed by the Engineer-in-Charge.The flush tank shall be of ISI marked, water-saving type, corrosion resistant, with mechanical or pneumatic dual-flush plate, suitable for concealed installation within the wall, and compatible with all standard EWC models. Make: Jaquar / Hindware / Cera / Kohler / Grohe / Parryware or equivalent as approved, Capacity : 6 L / 3 L (dual flush), Material : HDPE / UPVC concealed tank with chrome plated flush plate, Mounting : Wall concealed (suitable for brick/concrete wall), Operating pressure : 0.2 – 10 bar, Inlet : Bottom or side feed (as per manufacturer’s design),Flush pipe : 32 mm dia uPVC / HDPE |
| 79 | Providing and fixing first Quality Vitreous China hand wash Basin Consisting following items of work. - i) Providing Wash Basin and placing it in position as shown in the drawing or as per manufactures specification or as directed including finishing the joints with white / matching colour cement all complete. ii) Fixing various CP fittings such as Waste Coupling, Bottle Trap including fixing 32 mm minimum 10kg class PVC pipe conforming to IS:4985 (and fittings conforming to IS:7834). Placing and fixing Waste Pipe from Bottle trap to adaptor / Nahani trap / Floor Trap. iii) Fixing the Wash Basin in position, including providing M.S./C.I. Brackets & Screws for the basin. iv) Cutting hole, making grove or chases in the wall, floors, slabs etc., reinstating to it's original condition after completion of work, painting, finishing the gaps etc. all complete as directed by Engineer-in Charge. v) Fixing Vitreous China under / over the counter / semi recessed type Wash Basin of following model and make conforming to IS 2556 and placing it in position with the granite platform as shown in the drawing or as directed including finishing the joints with white cement all complete. vi) Testing the system to the full satisfaction of the Engineer in Charge |
| 80 | Vitreous China Wash Hand Basin of Campa Glitz model of Cera or equivalent table top model. |
| 81 | Providing & fixing in position best quality bevelled edge plane Glass Mirror with PVC frame of following size with 6 mm thick marine ply wood (confirming to IS:710), fixed with required numbers of CP brass cupscrews and caps, washers etc. including drilling holes, providing & fixing rawl plug in RCC/ brick wall, woodenpacking behind the mirror if necessary, reinstating the damages to its original condition etc. all complete as directed by EIC. |
| 82 | Designer plain glass Mirror of Approx. size 1300 x 1550 with 6 mm thick marine ply wood (confirming to IS:710:2010) backing & PVC moulded frame of approved shade or as directed by the E.I.C |
| 83 | Providing & fixing in position following approved quality brass material PVD coated fittings / Fixtures of 15 mm nominal dia. with ISI mark / approved make of following type including providing & fixing specials, wall flanges and fixing to concealed / exposed pipe line with leak proof threaded joints using tephlon tapes, testing the joints hydraulically to a pressure of 10 kg./ sq.cm, rectifying the leaky joints. if any, including cleaning etc. complete all as per specification. |
| 84 | French gold finish Chelsea angle Cock with wall flange of Cera Cat.No.F1016201FG or approved equivalent make. |
| 85 | French gold finish Chelsea Bib Cock with wall flange of Cera Cat.No.F1016151FG or approved equivalent make. |
| 86 | French gold finish Chelsea single lever basin mixer with wall flange of Cera Cat.No.F1016452 FG or approved equivalent make. |
| 87 | French gold finish H type Knob for dual flush arrangement including any concealed accessories required of Cera Cat.No.B1120101FG or approved equivalent make. |
| 88 | French gold finish Chelsea Dribble two function health faucet of Cera Cat.No.F8035101FG or approved equivalent make. |
| 89 | French gold finish Chelsea Wall mixer with wall flange of Cera Cat.No.F1016401FG or approved equivalent make. |
| 90 | French gold finish 300 x 300 mm square shower with arme of Cera Cat.No.F7010214FG or approved equivalent make. |
| 91 | Providing and fixing the following C.P. Brass PVD coated Bathroom / toilet accessories of following make and fixing on the wall using C.P. brass screws, rawl plugs etc. as per manufacturer's requirement all complete at the locations shown and as directed by the Engineer Incharge. |
| 92 | French gold finish Angular Stop Cock of Cera Cat.No.F1016201FG or approved equivalent make. |
| 93 | French gold finish Concealed Stop Cock of Cera Cat.No. F1016351FG or approved equivalent make. |
| 94 | French gold finish paper holder with lid of Cera Cat.No.F5014110FG or approved equivalent make. |
| 95 | French gold finish towel rod 450mm length of Cera Cat. No.F5014104FG or approved equivalent make. |
| 96 | French gold finish Napkin ring(square) of Cera Cat. No.F5014115FG or approved equivalent make. |
| 97 | French gold finish robe hook of Cera Cat. No.F5014108FG or approved equivalent make. |
| 98 | French gold finish liquid soap dispenser of Cera Cat. No.F5014111FG or approved equivalent make. |
| 99 | French gold finish soap dish of Cera Cat. No.F5014116FG or approved equivalent make. |
| 100 | French gold finish towel rack 600mm length of Cera Cat. No.F5014131FG or approved equivalent make. |
| 101 | French gold finish tumbler holder of Cera Cat. No.F5014107FG or approved equivalent make. |
| 102 | Providing and fixing of 12mm thick premium grade Safety-tempered /Toughten glass luxuary standard bath room partition glass of approved specification and including required brass fittings / brackets in wall, floor and ceiling etc.all as per drawings and as directed by Engineer-in-Charge |
| 103 | Supplying & fixing on Exposed surfaces the following dia. Galvanised iron pipe of specified class consisting following items of work:- i) Supplying galvanised mild steel screwed and socketed pipe conforming to IS:1239 (part-I) with galvanised mild steel or wrought steel fittings conforming to IS:1239 (part-II). ii) Laying and fixing the pipe and specials on exposed/concealed surfaces to correct line, level and plumb for water supply line, overflow and vent using screws, rawl plugs, wooden gutties and 'U' type G.I clamps having not less than 2 mm thick. the pipeline exposed as per the site requirement. iii) Testing the pipe line to a hydraulic pressure of 10 Kg / Sq.cm for leak proof joint. iv) Making leak proof threaded joints using White zinc, Spun yarn etc. including cutting the pipe, threading and the cost of jointing materials. v) Cutting or making hole or chases in RCC or brick work structure such as wall, column, beam, slab, chajja, dado etc. for passing the pipe line and reinstating all the damage to its original condition. proof joints. vi) Painting the pipe line after testing with two coats of flat oil paint of approved make and shade over a coat of approved primer. |
| 104 | 1). 15 mm (½\\") n.size |
| 105 | Supplying and laying below the ground or floor, the following diameter uv-stabilized Chlorinated Poly Vinyl Chloride (C-PVC) pipe line of specified class, consisting the following items of work:- i) Supplying CPVC pipes and all required CPVC plain / brass threaded fittings, SDR - 11 having thermal stability for hot & cold water supply of approved make conforming to IS:15778 with ISI mark for CPVC pipe having nominal size up to 50 mm and conforming to ASTM F 441 (IPS SERIES) Schedule 40/80 for CPVC pipe having nominal size 65 mm (2½”) and above. ii) Laying and fixing the pipe and specials below the ground or floor to correct line, level and plumb for water supply line. iii) Making leak proof threaded/welded joints. including cutting the pipe, cleaning, marking, jointing, etc. and including the cost of jointing materials. iv) Cutting or making hole or chases in RCC or brick work structure such as wall, column, beam, slab, chajja, dado etc. for passing the pipe line and reinstating all the damage to its original condition. v) Providing and fixing C-PVC weldable / threaded fittings such as Union, Nipples, Bends, Elbows, Tees, Reducers, End caps, Couplers, Adaptors, Saddles, Plugs, Tank connectors, Expansion loops, Bypass bends, etc.vi) CPVC pipes and fittings shall be of same brand. iv) Testing the pipe line as per relevant code to a hydraulic pressure of 10 Kg/Sq.cm to assess leakages if any, rectifying the defect, retesting etc till water tightness of pipe line is ensured NOTE:- 1) The rate shall also include for cPVC pipe & specials required for making connections with the existing GI / CPVC pipe line laid by other agency. 2) All threaded joints shall be made with brass threaded fittings Only. 3) Excavation and refilling shall be paid under relavent item. |
| 106 | 20 mm(¾\\") n.size (SDR-11 as per IS:15778) |
| 107 | 40 mm (1½\\") n.size (SDR-11 as per IS:15778) |
| 108 | 50 mm (2\\") n.size (SDR-11 as per IS:15778) |
| 109 | Providing uPVC Floor Trap/ Nahani Trap of following size having not less than 40mm effective water seal, fixing the trap in position and connecting with waste water pipe by cement solvent/ as per manufacturer's recommandation, embedding the trap in cement concrete 1:2:4 to correct level and gradient, providing and fixing 150 x 150 mm size top tile with central strainer & flat cover/ flush strainer, closing the side inletes with plugs if required etc. complete all as per specification and as directed by the Engineer in charge. |
| 110 | Multifloor trap of 110 x 75 x 50 size of approved make with C.P. Brass/SS 3 pc top tile & flush strainer, Satin finish., including Chilly /Cockroach Trap of approved make in C.P Brass / SS. |
| 111 | Providing and fixing Rectangular Long Metal Concealed Stainless Steel Shower Drainer, fabricated from 304 grade stainless steel, having rectangular linear type top grating and concealed frame, suitable for bathrooms and shower areas, including integrated deep-seal waste trap or detachable trap, outlet connection suitable for 50 mm / 75 mm dia pipe, and brushed satin finish. The drainer shall be fixed flush with floor level using cement mortar 1:3, including cutting and making good the floor, leak-proof sealing, all fittings and accessories, complete as per manufacturer’s specifications and direction of the Engineer-in-Charge. |
| 112 | Size: 600 mm to 1000 mm (length) × 70 mm to 100 mm (width). |
| 113 | Supplying and fixing following size uPVC UV-Stabilised soil / waste quality pipes and fittings ( SWR ) for soil, waste, vent, anti syphonage, HVAC waste pipe and rain water pipe lines consisting following items of work:-i) Providing and fixing uPVC UV-Stabilised Soil/ waste pipe as per IS:13592 and IS:14735 Type-B laid in floor & on Exposed faces of wall of approved makeii) Fixing the pipeline vertically by Metal clamps with rubber seal of approved makeiii) Fixing the pipeline Horizontaly with specified slope below the ceiling by Metal clamps with rubber seal and GI hanger rods not less than 5mm dia at specified spacing, including all required hardware.iv) Providing and fixing uPVC cowl at the top of soil, waste water & vent pipe line.v) Providing and fixing uPVC P/S trap on line as per requirement for soil,waste water pipeline.vi) Laying the pipe below floor / ground to the slope and gradient equal to (or) steeper than 1 in 50, making leak proof connections of soil /waste pipe line from the shaft with inspection chamber / Manhole / Gully trap Chamber including the cost of filling around the holes of inspection chamber / Manhole / Gully trap with cement mortar 1:1 mixed with water proofing compoundvii) Jointing the pipe / fittings with Solvent Cement & Rubber ring gasket with making holes in walls / floor grooving and redoing the same and brick support etc. Carrying out water-tightness test for the pipes laid as per codal provisions. Providing Ring Joint pipes at verticals and solvent cement jointed pipes at concealed locations.viii) Cutting the pipe to the required length including providing short pieces, necessary connectors, fittings & specials with & without door, assorted fittings such as plugs, tees, couplers, reducers, cross tees, reducing tees, elbows, bends, single & double Y, vent cowl, gaskets, offsets etc. including providing necessary clean outs, cleaning pipe, extension pipe if any for clean outs, door bend, door elbow, door Y, socket plug, etc wherever required for accessing every segment of soil and waste pipes to enable removal of any Chock up after installation. ix) Providing necessary specials for connecting UPVC SWR (IS:13592/ IS:14735) pipe with UPVC (IS:4985) pipe etcx) Dewatering the pit/ trenches if necessary till completion of workxi) Testing the pipe line for any leakages, rectifying the leakages if any, retesting etc., till water tightness of the pipe line is ensured.xii) Exposed pipe fixing arrangement include slotted G.I. section and U clamps.Note: Earthwork excavation for trenches shall be paid under relevant itemsFor Soil & waste, Vent and Rain water pipe lines |
| 114 | 75 mm dia. |
| 115 | 110 mm dia. |
| 116 | PART-C :FURNITURE (UPGRADATION) WORKS |
| 117 | Providing and making decorative frames of bed, study tables, dresser tables, side tables, drawers and other frames by using second class teak wood in wrought framed and fixed in position of required size and shape including sawing, jointing, making rebates for shutters, making grooves as shown in the drawings, finishing the surfaces to the required finish all as per specifications and drawings including necessary MS hold fasts 40 mm X 3 mm thick, 200 mm long / with coach screws including protective painting to the suface that will come in contact with walls, joining materials, labour and including finishing as specified etc. complete all as per specifications and as directed by the Engineer-in-charge |
| 118 | Providing and making wooden chairs using first class C.P teak wood of required sizes and sections as per design and patterned approved by Architect including carving including providing seating & back cushion with approved fabric for making complete wooden chairs including one coat of primer polish and 2 coat of PU polish etc. as patterned & design approved by architect including cutting & jointing the wood, providing and fixing necessary screw and gluing the lap joints or tong & grovee joints with synthetic adheshesiive fevicol in proper line and level including cost of fixing, making & jointing etc. all complete as per specification and drawing and as directed by the Engineer-in-Charge. |
| 119 | Providing and fixing carpet having 75 % wool & 25 % silk and min thickness 10 to15 mm, as per approved design, including material, labour, wastage, transportation and taxes. etc. complete all as as per drawings and as directed by Engineer-in-Charge |
| 120 | Supply and installation of a circular coffee table with a diameter of 600 mm, The table should be crafted from premium teak wood materials with a sophisticated design including providing, assembling, fixing and including applying 3 coats of approved shade /colour Acrylic Polyurethane coatings (PU base Polishing) of Asian or equivalent etc. all complete as per drawings and as directed by Engineer-in-Charge |
| 121 | Providing and fixing superior quality roller blinds of approx. size 3000 mm x 2400 mm. of M/s. VISTA or approved equivalent manufacturer with approved best quality fabric with painting design as aproved , including control unit, head rail, roller tube, bottom rail, operating chain and fixing arrangement as per specification and including accessories required for fixing in position including labour material etc complete all as per approved sample, design, pattern complete all as per manufacterers specification and as directed by the Engineer-In-Charge. |
| 122 | Supply and installation of high-quality SS curtain rods with end and midle support. The channels should be made from durable materials with a sleek finish. Installation includes mounting the channels and ensuring smooth curtain operation etc. all complete as per drawings and as directed by Engineer-in-Charge |
| 123 | Providing and supplying high-quality 6'' Thick ( 150 mm ) required size mattress made from premium quality foam with coir/PU foam/bonnell spring construction, having quilted fabric cover on both sides, suitable for daily use in guest house/residential accommodation.The mattress shall be of reputed make such as Sleepwell / Kurlon / Duroflex / Centuary / MM Foam / or equivalent, with medium-firm comfort level, having anti-fungal, anti-dust mite and breathable upholstery fabric.The item includes delivery, placing in position and removing all packaging waste, complete as directed by the Engineer-in-Charge. |
| 124 | Providing and fixing telescopic drawer sliding soft closing channel of hettich make or equivqlent approved heavy-duty make and quality, of Following Size including fixing with necessary screws, proper alignment, smooth operation and complete as per direction of the Engineer-in-Charge. |
| 125 | a) Size 24'' Long |
| 126 | b) Size 22'' Long |
| 127 | c) Size 16'' Long |
| 128 | d) Size 12'' Long |
| 129 | e) Size 10'' Long |
| 130 | Providing and fixing Brass L/ W hinges 100 mm ISI marked of approved make with necessary screws, complete as per specifications, as per manufacturers specifications, drawing & as directed by the Engineer-in-charge. |
| 131 | Providing and fixing Heavy duty brass drawer & Shutter handle of any shape/design/pattern/texture of following size of approved make and finish, fixed with screws, complete as per specifications, drawing & as directed by the Engineer-in-charge. |
| 132 | a) 100 mm long |
| 133 | b) 150 mm long |
| 134 | c) 300 mm long |
| 135 | Providing and fixing approved make ( Godrej or equivalent) Cyledrical lock with gold finish and 60 mm bracket, SS knob with & without key, screw etc. complete all as directed by Engineer Incharge. |
| 136 | a) Cylindrical Lock of Gold finish and 60 mm bracket, SS knob withiout key for bathroom door shutter. |
| 137 | Providing and fixing of gold finish 6 Lever Mortice Lock (Brass 100 mm mortice latch and lock with a pair of lever handle) of approved make suitable for aluminium sections with necessary screws, material, labour, cutting, making good etc complete all as per specifications and as directed by the Engineer-in-Charge. |
| 138 | Providing and fixing brass Tower Bolt of following size of approved make and finish, fixed with screws, complete as per specifications, drawing & as directed by the Engineer-in-charge. |
| 139 | a) 150 mm long Brass tower bolt. |
| 140 | b) 300 mm long Brass tower bolt. |
| 141 | Providing and fixing Godrej make drawer lock (6-lever) with keys, screws and accessories, including cutting and making good, complete as per specifications, drawing & as directed by the Engineer-in-charge. |
| 142 | Providing and fixing main door aldrop 300mm long 16mm dia of approved make in brass with all screws and plates, complete as per specifications, drawing & as directed by the Engineer-in-charge. |
| 143 | Providing and fixing brass door/cupboard shutter safety chain of approved make with screws, complete as per specifications, drawing & as directed by the Engineer-in-charge. |
| 144 | Providing and fixing brass door viewer (peep hole) of approved make, including drilling and fixing, complete as per specifications, drawing & as directed by the Engineer-in-charge. |
| 145 | Providing and fixing floor/wall mounted brass door stopper of approved make with rubber buffer and screws, complete. |
| 146 | Providing, Fixing & assembling/ fixing at site Table top/ cupboard /shelves /wall cabinets etc. using following material of approved quality machine pressed phenol formal dehyde bonded marine plywood of IS 710 latest revision, and both /single face laminatite /one side vineer and one side laminate of approved shade and make on both faces , all edges covering with 12 mm thick teak wood Patti or other approved equivalent , using approved glue for pressing, approved quality PVC wire manager for taking out all wiring etc. and carefully fixing to the vertical partition including all materials adhesives, S S screws labours, materials, wastages etc. all as per approved drawing and as directed by EIC. Note:- No separate measured for payment will be made for decorative laminate. |
| 147 | b) 12 mm thick marine ply. |
| 148 | a) 19 mm thick marine ply. |
| 149 | c) 1 mm thick laminate |
| 150 | d) 3.5 mm thick teak veneer |
| 151 | Applying three coats of Acrylic Polyurethane coatings (PU base Polishing) of Asian or equivalent make on new/old wooden surface table top, cladding & cabinet with approved tint & make to obtain required finish over a coat of wood filler including spray gun, sand papering, cleaning, filling up holes, cracks & crevices with approved quality wood filler including labour, tools & plants etc. making even surface with line, level & plumb etc. complete all as directed by the Engineer-In-Charge. |
| 152 | Providing and fixing wall panelling at all floors and locations consisting of following thickens water proof marine ply wood of Anchor or approved make conforming to IS 710 latest version on aluminium fame work on wall including suitable screw of required size and providing 3 mm wide grooves between veneer panels of different shades ( dark and light colour) including applying 3coats of Acrylic Polyurethane coatings (PU base Polishing) of Asian or equivalent make on new/old wooden surface after preparing the surface, scaffolding, tools, screws, rawal plug etc. including making cut out for electrical fittings and fixtures with shutter handle, hinges etc. complete all as per specification, as per architectural drawing and as directed by the Engineer-In-Charge. NOTE:- Aluminium frame work shall be on relevant Item. |
| 153 | a) 19 mm thick marine ply. With 3.5 mm thick teak veneer on top /exposed surface. |
| 154 | b) 12 mm thick marine ply. With 3.5 mm thick teak veneer on top /exposed surface. |
| 155 | Supply and installation of CNC carved teak wood wall panelling of size approx. 450 mm x 450 mm, 25 mm thick The panels should be meticulously crafted with intricate carvings. Installation includes precise fitting, securing the panels, and finishing etc. all complete as per drawings and as directed by Architect or Engineer-in-Charge. Note : Teak wood bidding patti and polishing work payment paid in separate item.) |
| 156 | Supply and installation of 12 mm thick bison board for partitions or paneling. The board should be of high quality, suitable for luxury interiors. Includes cutting to size, fitting, and finishing etc. all complete as per drawings and as directed by Engineer-in-Charge |
| 157 | Supply and installation of bed head board of approx size 76 inches x 32 inches, consisting of 19mm ply @ back and finished with high-density PU foam padding. The head board should be approved upholstered in premium fabric and mounted securely to the wall for both comfort and aesthetics etc. all complete as per drawings and as directed by Engineer-in-Charge |
| 158 | Supply and Installation of a luxury mirror glass (Approx size 1.6 M X 1.0 M) & framed with approved teak wood moulding. The mirror glass should feature a high-quality reflective surface and be securely mounted on the dresser table including required adhesive material, screw etc.. all complete as per drawings and as directed by Engineer-in-Charge |
| 159 | Supply and installation of art piece ledges measuring 16 inches by 8 inches by 5 inches. Ledges should be crafted from premium materials and securely mounted to display art work etc. all complete as per drawings and as directed by Engineer-in-Charge |
| 160 | Supply and Installation of PVC heavy duty fluted panel including all necessary materials, labour, tools and equipment's. panel should be high quality, UV- stabilized PVC, resistance to moisture, fire and termite damage, with minimum thickness of 12 mm. work includes surface preparation, cutting pannels to size, erection of supporting substructure if required secure fixing using fastners/screws/adhesives, joint treatment with sealents, and ensuring proper alignment and finish as per specification, as per drawing and as directed by the Engineer-in- Charge |
| 161 | Providing and fixing following size of approved decorative teak wood frame as per department for making of printing/photo frame including applying 3 coats of PU polish by machine, material, labour, wastage, transportation, taxes and necessary fixing arrangement etc. complete all as directed by Engineer In charge. |
| 162 | Size 50 mm x 75 mm |
| 163 | Size 38 mm x 19 mm |
| 164 | Size 40 mm x 40 mm |
| 165 | Size 40 mm x 25 mm |
| 166 | Aluminium WorkSupplying and fixing in position at all floors, levels & locations, aluminium section [extruded] for aluminium Door / windows sliding / top hung/fixed / grill/ adjustable louvered/ windows as per drawing of approved manufactures with extruded sections of Jindal / Indal / Aluminax or other approved eqivalent sections with size and weights as shown in the drawing, for frames and shutters [including wastages if any] conforming to relevant I.S specifications, with all approved shade & colour anodised aluminium fittings and accessories, locking arrangements, 2 / 3 rollers with ball bearings for sliding shutters of approved quality all as shown in the drawing, including providing and fixing aluminium channel beading / glazing clips fixed with necessary matching anodised screws, grouting the gap with thermocole & polysulphide sealant etc. all complete generally as per drawings, specifications etc., all as directed by Engineer in charge. but excluding the cost of glazing,which will be paid separately. (Note:- Sliding window sections for both track & Shutters shall be of JINDAL DELUXE DOMAL SERIES or aproved serise or similar equaivalent approved make. ) |
| 167 | Using integrated anodised (of approved colour & Shade) having glossy/matt finished [Minimum anodic coating of 15 micron thick (Grade AC-15)] aluminium section. |
| 168 | Providing & fixing following thickness of clear float / ordinary plain / frosted / bajara sheet glass/ for M/S Triveni / Shree vallabh / IAG / /Modi Guard / Saint Gobin or other approved equalling manufacture and fixing with aluminium frame work, doors, windows including facing aluminium channel beading and providing and fixing two way EPDM / PVC casketing to ensure water and air tightness and neoprene cushions / gasket accommodated in grooves, necessary bronze anodised screws etc. including wastage in cutting, transportation etc. complete all as per specification and drawing and as directed by the Engineer-in-Charge. |
| 169 | a) 5.0 mm thick Bajra (pin headed) / Translucent glass |
| 170 | b) 6.0 mm thick toughen glass. |
| 171 | Supplying & fixing in position the following type solid core block board flush door shutter (Single/ double leaf) with commercial ply facing / prelamination on both sides conforming to IS 2202 (Part-1) of approved make & brand with external / internal type second class teak wood lipping alround of required width and depth (20 minimum thickness all around) of shutter as per IS/as specified, fixing shutters in position to HMPS door frames/ wooden frames/ granite frame works (door frames shall be paid separately under relevant item) at all floors by cutting/ planing if necessary including labour for fixing of the fittings & fixtures as per drawing with wooden packing pieces if necessary (but excluding the cost of fittings and fixtures with SS screws which shall be paid separately under relevant item), including view panel wherever required as per drawing, finishing as specified all as per specifications, drawings and as directed by Engineer In Charge. |
| 172 | a) 35 mm thick |
| 173 | Supplying & fixing in position at all floors and location 25mm thick PVC integral free foam sheet in the form of flush finished door shutter manufactured by M/s. Jain Irrigation Systems Ltd. ( Ex-cel sheet), M/s. Rajshri plastiwood or approved equivalent of white/approved colour solid section, extruded rigid, light weight sheet with fine and homogeneous closed cell structure with smooth, glossy, hard surface finish on both sides including providing recess for hinges, shutters in position to granite/ steel frames (Frame shall be paid separately under relevant item) at all floors by cutting / planing required if any, fixing with wooden packing pieces if required, including finishing all edges smooth with mixture of PVC powder & solvent including wastages, labours tools etc all as per specifications, drawings & as directed by the Engineer in charge. |
| 174 | PART: D- ELECTRICAL & AC WORKS |
| 175 | Disconnection & dismantling of the all existing electrical accessories like Fans,lighting fixtures, Gyser, window type ACs,concealed switch boxes whereever requried etc. in the area under renovation as per the drawings attached and depositing same at DCSEM stores, Anushaktinagar/TV stores Trombay including loading, unloading & trasnportation and as per instruction of EIC. |
| 176 | Casing capping & Conduit Pipes. |
| 177 | Supply installation testing & commissioning of 25 x 16 mm casing capping on surface of slab / wall / column fixed with nylon / rawal plug, GI wood screws at the intervals of 300mm includes providing the tags for wires inside casing capping for bunching to avoid hanging of wires at the intervals of 600mm as per the instruction of Engineer-in-charge. |
| 178 | Supply installation testing & commissioning of 25mm dia rigid HMS PVC of conduit with all required accessories like junction box , bend, etc. on surface of slab / wall / column fixed with PVC spacer saddles , nylon / rawal plug, GI wood screws at the intervals of 300mm as per the instruction of Engineer-in-charge. |
| 179 | Supply installation testing & commissioning of 19mm dia rigid HMS PVC of conduit with all required accessories like junction box , bend, etc. on surface of slab / wall / column fixed with PVC spacer saddles , nylon / rawal plug, GI wood screws at the intervals of 300mm as per the instruction of Engineer-in-charge. |
| 180 | Supply installation testing & commissioning of 25 mm dia FRPP flexible conduit with PVC gland on surface of slab / wall / column fixed with PVC spacer saddles, nylon / rawal plug, GI wood screws as per the instruction of Engineer-in-charge. |
| 181 | Making of grooves by cutting the floor tiles /floor/wall with cutter machine and supply & laying HMS PVC of 19mm dia rigid conduit with all required accessories line junction box , bend, etc. for laying power & control cable/ wires as required, refilling the grooves with cement concrete & finishing the surface as per original. |
| 182 | Making of grooves by cutting the floor tiles /floor/wall with cutter machine and supply & laying HMS PVC of 25mm dia rigid conduit with all required accessories line junction box , bend, etc. for laying power & control cable/ wires as required, refilling the grooves with cement concrete & finishing the surface as per original. |
| 183 | Recess mounted LED lighting Fixture |
| 184 | Supply, installation, testing & commissioning of recess mounted round/square downlight LED fixture with min efficacy :- 100lm/W, min.lumen output :- 2100 Lm ,CCT :- 3000min.CRI :- 80min. P.f :- 0.95min. I.P :- 20Housing:- Pressure die cast Al.sutiable for 150/140mm dia cut-out and as per tender specification.Note:-The fixture to be got approved by department before manufacturing/supply. If the cutout at site is more than the specified product ,then an additional adopter (outer ring) to mount which would be in electrical contractor scope.Warranty certificates shall be submitted to department. Scope work also includes dismantling of the exisitng fixtures. |
| 185 | Supply, installation, testing & commissioning of recess mounted round spotlight LED fixture with min efficacy :- 100lm/W, min.lumen output :- 700 Lm ,CCT :- 3000min.CRI :- 80min. P.f :- 0.95min. I.P :- 20Housing:- Pressure die cast Al.sutiable for 95mm dia cut-out and as per tender specification.Note:-The fixture to be got approved by department before manufacturing/supply. If the cutout at site is more than the specified product ,then an additional adopter (outer ring) to mount which would be in electrical contractor scope.Warranty certificates shall be submitted to department. |
| 186 | Supply, installation, testing & commissioning of LED strip light with Aluminium profile & driver similar to model no. Pro Glow LED Strip Light 45W with Driver of M/s. Philips, complete with accessories & required hardware as required & instructed by E-I-C. |
| 187 | LED lighting Fixture |
| 188 | Supply, installation, testing & commissioning of 12\\" LED picture light fixture similar to model no. Muziris of M/s. Philips make, complete with accessories on wall/ slab / beam by suitable anchor fasteners / coach screw/ SS screw etc. required hardware as required & instructed by E-I-C. |
| 189 | Supply, installation, testing & commissioning of LED Wall light fixture similar to model no. Nero single head wall light PH1768 (582086) of M/s. Philips make( Photo enclosed ), complete with suitable 8W Full Glow Glass LED Lamp of M/s Philips accessories on wall/ slab / beam by suitable anchor fasteners / coach screw/ SS screw etc. required hardware as required & instructed by E-I-C. |
| 190 | Supply installation testing & commissioning of LED tube light fixture similar to TMC 501 P 1 x T-LED 22W P3241 with 1 nos 2100Lm Tubelight warm white 3000K complete with mounting accessories on surface of slab / beam / wall with required hardware, interconnections between light point and light fixture with copper flexible TRS wire all as required & instructed by E-I-C. |
| 191 | Supply installation testing & commissioning of 10W LED wall light similar to model no.Propulsio Wall light of M/s. Philips make complete with mounting accessories on surface of slab / beam / wall with required hardware, interconnections between light point and light fixture with copper flexible TRS wire all as required & instructed by E-I-C. |
| 192 | Supply,installation, testing & commissioning of designer table lamp similar to model no.Jazz of M/s. Philips. Installation includes wiring the lamps and placing them on specified surfaces etc. all as per drawings and as directed by Engineer-in-Charge |
| 193 | Supply, installation, testing & commissioning of 12W LED surface mounted light similar to sleek surface of M/s. Philips. |
| 194 | Supply installation testing & commissioning of LED skirting light with suitable driver, as per specifications, drawing & as directed by the Engineer-in-charge. |
| 195 | Supply installation, testing & commissioning of 1320 mm Ceiling fan with under light similar to Florrette UL BLDC+ of M/s. Havells (speed control with remote) with safety chains including interconnection to ceiling rose with 3C X 1.0 sq.mm flexible copper cable. |
| 196 | Supply, installation, testing & commissioning of 300mm sweep exhaust fan similar to model Ventilair DB of m/s. Havells complete with supply cord and 3 pin top. |
| 197 | Providing Ceiling fan hook fabricated out of 150mm x 150mm x 10mm (Approx.) MS sheet with 12mm MS rod hook wilded on MS sheet, holes on corners & painting with two coat of enamel paint over one coat of red oxide and with four nos. of anchor fasteners 10mm dia ( Approx.), all as required & instruction of Engineer-in-charge (Sample to be got approved) |
| 198 | Supply installation, testing & commissioning of 35 Ltr Storage type water heater similar to CDR DLX PLUS storage water heater of M/s Racold operating on 240V AC ,50Hz supply complete with all accessories. ISI marked, connecting to water heater point with minimum 3C X 2.5 sq.mm copper conductor flexible chord. |
| 199 | Supply and installation of 43-inch LED television with high-definition display capabilities. Installation includes wall or stand mounting, connecting power and signal cables and calibrating the TV for optimal viewing etc. similar to Samsung 108 cm (43 inches) D Series Crystal 4K Vivid Ultra HD Smart LED TV UA43DUE70BKLXL (Black) and as directed by Engineer-in-Charge Other features are as follows:1)Resolution: 4K Ultra HD (3840 x 2160) Resolution | Refresh Rate: 50 Hertz.2)Display Features: Crystal Processor 4K | PurColor | 4K Upscaling | HDR 10+ Support | HDMI Black Level | Mega Contrast | UHD Dimming | Contrast Enhancer | Motion Xcelerator | Filmmaker Mode || Additional Features: Endless Free Content | Samsung Knox Security (Your privacy. Secured.) | ConnectShare | TV Key.3) Sound Features: 20W Output- 2CH | Powerful Speakers with Q-Symphony | Object Tracking Sound | Bluetooth Audio | Adaptive Sound.4) Smart TV Features : Bixby Voice Ready (Control your Crystal UHD TV with Bixby Voice through SmarThings App) | Works With AI Speaker (Alexa and Google Assistant) | Mobile to TV Mirroring | Sound Mirroring | Wireless TV On | Buds Auto switch | Web Browser | SmartThings Hub / Matter Hub / IoT-Sensor Funtionality | Apple AirPlay | Daily+ || Gaming Features: Auto Game Mode (ALLM) | VRR | HGiG.5) Connectivity options: 3 Hdmi Ports For Seamless Connectivity With External Devices | 1 X Usb-A Usb Ports To Connect Hard Drives Or Other Usb Devices | Wi-Fi | Bluetooth | Anynet+ (Hdmi-Cec) | Ethernet (Lan) Port | Rf In (Terrestrial) |
| 200 | Supply and installation of 55-inch LED television with high-definition display capabilities. Installation includes wall or stand mounting, connecting power and signal cables and calibrating the TV for optimal viewing etc. similar to Samsung 108 cm (43 inches) D Series Crystal 4K Vivid Ultra HD Smart LED TV UA55DUE70BKLXL(Black) and as directed by Engineer-in-Charge Other features are as follows:1)Resolution: 4K Ultra HD (3840 x 2160) Resolution | Refresh Rate: 50 Hertz.2)Display Features: Crystal Processor 4K | PurColor | 4K Upscaling | HDR 10+ Support | HDMI Black Level | Mega Contrast | UHD Dimming | Contrast Enhancer | Motion Xcelerator | Filmmaker Mode || Additional Features: Endless Free Content | Samsung Knox Security (Your privacy. Secured.) | ConnectShare | TV Key.3) Sound Features: 20W Output- 2CH | Powerful Speakers with Q-Symphony | Object Tracking Sound | Bluetooth Audio | Adaptive Sound.4) Smart TV Features : Bixby Voice Ready (Control your Crystal UHD TV with Bixby Voice through SmarThings App) | Works With AI Speaker (Alexa and Google Assistant) | Mobile to TV Mirroring | Sound Mirroring | Wireless TV On | Buds Auto switch | Web Browser | SmartThings Hub / Matter Hub / IoT-Sensor Funtionality | Apple AirPlay | Daily+ || Gaming Features: Auto Game Mode (ALLM) | VRR | HGiG.5) Connectivity options: 3 Hdmi Ports For Seamless Connectivity With External Devices | 1 X Usb-A Usb Ports To Connect Hard Drives Or Other Usb Devices | Wi-Fi | Bluetooth | Anynet+ (Hdmi-Cec) | Ethernet (Lan) Port | Rf In (Terrestrial) |
| 201 | Split Air-conditioner: Supply, installation, testing and commisioning (SITC) of 1.8 TR wall mounted 5 star rated Invertor hi-wall Split AC units/ ceiling suspended ceiling concealed split AC units of follwing nominal cooling capacities(Minimum) as per technical specifications and instructions of Engineer-in-Charge. Note: 1.The outdoor unit shall be provided with 10 mm thick neoprene pads. 2.The price is inclusive of consumables, leak testing, refrigent gas that may be required to put the air conditioner into service and no extra payment shall be made for the same. 3.The cutout for regrigerant pipe cable and drain shall be included in scope and no extra payment shall be made for the same. 4.The ODU dimension shall be suitably selected for mounting in the space available in the parapet(approaximately 1000 mm width and 800 mm depth) without compromising on the condensor cooling and rated cooling capacity of the indoor unit as well as servicability. 5. On site warranty of Compresser shall be min. 10 years and PCB shall be min. 5 year from date of supply of units. Warranty certificates shall be submitted for each units while supplying the units. 6. Anti corrosive coating shall be done for fins of ODU at works of OEM |
| 202 | Refrigerant Piping with Nitrile Rubber insulation (Combined Suction line & Discharge line): Supply, installation, testing and commissioning of Interconnecting refrigerant copper piping ( suction & discharge line) of suitable sizes for above split AC units duly insulated with closed cell tubular elastomeric nitrile rubber of minimum density not less than 33kg/cum of thickness 13 mm thick for size upto 19.05 mm dia. pipe and 19 mm thick for sizes above 19.05 dia pipes as per technical specifications, manufacturer's recommendations and instructions of Engineer-in-Charge. Note: Scope of work also includes the following: i) coating of the copper ppies with transparent anti corrosive primer before insulation. ii) The insulation shall be mechanically protected with a coat of polyshield of approved colour (starbond 30-36 or equivalent) of minimum 5 mil thickness. |
| 203 | Drain piping duly insulated: Supply, installation and commissioning of 25mm dia. rigid / flexible HD PVC piping duly insulated with closed cell elastomeric rubber insulation as per technical specifications and instructions of Engineer-in-Charge |
| 204 | Cabling: Supply & laying of following sizes of flexible copper power/control cabling to connect outdoor units with respective indoor units / power cable to connect power outlet to ODU/ IDU complete with end connections with suitable copper lugs as required all as per technical specification and instructions of Engineer-in-Charge. |
| 205 | 4 core x 2.5 sq.mm flexible cable |
| 206 | 3 core x 2.5 sq.mm flexible cable |
| 207 | Supply installation testing & commissioning of flexible wires of 1100V grade, FRLS PVC insulated multi stranded copper wires in existing concealed conduit of following sizes. |
| 208 | 1.5 Sq.mm |
| 209 | 2.5 Sq.mm |
| 210 | 4.0 Sq.mm |
| 211 | PVC Truncking: Supply & laying of casing and caping (PVC trunking 100 mm (Width) X 50 mm(Depth) for enclosing refrigerant tubing with insulation, drain line and electrical cable as per technical specifications and instructions of Engineer-in-Charge. |
| 212 | M.S. supports: Supply, fabrication & installation of M.S. stand for the ODU (outdoor unit) of AC unit as required fabricated out of M.S. flat of size (50 mm x 8 mm) and M.S. angle of size (50 mm x 50 mm x 8 mm) and safety guard of M.S. flat of size (12 mm x 12 mm) with suitablle opening for maintenance purpose of ODU unit, painting with two coats of synthetic enamel paint over one coat of red oxide primer of approved make & shade to all M.S. parts at all levels & elevations as required and as per technical specification and instructions of Engineer-in-Charge. |
| 213 | Suplly, installation,testing and commissioining of 25A,DP MCB with socket in enclosure as controlling switch including all accessories excluding wire & conduit (Wires & conduit will be paid as per respective items). |
| 214 | Replacement of existing modular switches, sockets complete with metal box, Metal frame & plastic cover plate matching with existing wall wooden panel shade. |
| 215 | 1/2M plate with cover |
| 216 | 3M plate with cover |
| 217 | 4M plate with cover |
| 218 | 6M plate with cover |
| 219 | 8M plate with cover |
| 220 | 6X2M plate with cover plate |
| 221 | 6X3M plate with cover plate |
| 222 | Supply installation testing & commissioning of 6 X 2 module wooden finish mdoular plate with 8 no.s of modular bell call indicators with registor, complete with 4 no.s of modular buzzers, concealed box, cover plate, frame & label similar to Myrius of M/s. Legrand make. |
| 223 | Supply, installation, testing & commissioning of readymade 4-way, MCB enclosure with 25/32A 4P MCB complete as per specifications, drawing & as directed by the Engineer-in-charge. |
| 224 | Supply, installation, testing & commissioning of readymade,IP43, 4 way VTPN MCB DB,Powder coated, double door type consisting of following components all as required,fixing on wall as instructed by the Engineer-in-charge.i) 63A 4P MCB - 1 no.ii)25/32/40A,3P,10kA,C-curve,MCB - 4 each.ii)Wire way box of same make,Din channel, tinned copper bus bar, earthing and neutral links etc.---1 set |
| 225 | Supply installation, testing & commissioning of RG-6 TV coaxial cable complete with socket, concealed box, plastic cover plate matching with existing wooded panel shade in existing conduit on wall /concealed with termination as per specification & as instructed by EIC |
| 226 | Supply, installation testing & commissioning of 5 pair telephone cable complete with RJ-11 socket, concealed box, cover plate matching with existing wooden panel shade in existing conduit on wall /concealed with termination as per specification & as instructed by EIC |
| 227 | Supply installation testing &commissioning of CAT-6 cable with RJ 45 socket complete with concealed box, plastic cover plate matching with existing wooded panel shade in existing conduit on wall /concealed with termination as per specification & as instructed by EIC |
| 228 | Supply, installation, testting and commissioning of 25 A DP MCB with enclosure fix on wall with nylon plug screw etc., all as required and instructed by the engineer-in-charge |
| 229 | Supply and installation of 32 A DP switch similar to cat no. 6792 17 of M/s. Legrand make. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
| 8 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail