| 1 | Fire Fighting System:Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : DSR 2022 SI No 18.7 |
| 2 | 25 mm dia (18.7.1) |
| 3 | 32 mm dia (18.7.2) |
| 4 | 40 mm dia (18.7.3) |
| 5 | 50mm dia (18.7.4) |
| 6 | 65mm dia (18.7.4) |
| 7 | 80 mm dia (18.7.6) |
| 8 | 100 mm dia (18.7.7) |
| 9 | 150 mm dia (18.7.8) |
| 10 | 200 mm dia (18.7.9) |
| 11 | Supplying Installation testing & Commissioning of 25 mm Ball valve PN -1 gunmental as per IS:778 including necessary accessories and connections. MR |
| 12 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. DSR 2022 SI No. 18.20 |
| 13 | (A) Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required :(B) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.(C) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-’F' insulation, conforming to IS-325.(D) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.(E) Suitable cement concrete foundation duly plastered with anti vibration pads..DSR 2022 SI No. 18.1 |
| 14 | 2280 LPM 70 MTR HEAD As Per DSR 2022 Si no. 18.1.5 |
| 15 | Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection Class IP 42 as required DSR 2022 SL No 18.5.1 INCOMING250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector swtich & CTs etc.LED type RYB phase indicating lamps, ON, OFF, trip indicating lampsSet of Copper Bus Bar 300AOUTGOING( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)MAIN FIRE PUMP125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. JOCKEY PUMP63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. |
| 16 | DIESEL ENGINE CONTROLControl for diesel engine comprising -Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engineSYSTEM CONTROLLERDesigning, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification |
| 17 | (A) Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)(B) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520(C) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325.(D) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.(E) Suitable cement concrete foundation duly plastered and with anti vibration pads.. 900 Lpm at 35 m Head DSR 2022 SI No. 18.4.1 |
| 18 | Providing/Fixing of cubical type floor mounted Fire pump control panel fabricated from 16 G M.S. sheet duly powder coated finish of approved shade and comprising of :a) One 63 amp. TP+NL M.C.C.B with rotary handle of beacking capacity 35 KA.b)One Volt meter (0-500 V) with selector switch.c) One set including lamps. d) Star/Delta starter with overload protection current sensing type single phase prevention complete with accessoriese) Necessary Internal Wiring for automatic operation. (MR) |
| 19 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. DSR SI No.18.22 |
| 20 | Providing & fixing of Flow switch in Following sizes in M.S. pipe line including connection etc. as required. DSR SI No.18. 23150 mm Dia. |
| 21 | Providing and fixing in position the industrial type pressure gauges with gun metal/brass valves complete as required DSR-2022 SI No. 16.8 |
| 22 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : DSR 2022 SI No 18.11 |
| 23 | 80 mm dia (18.11.4) |
| 24 | 100 mm dia (18.11.5) |
| 25 | 150 mm dia (18.11.6) |
| 26 | 200 mm dia (18.11.7) |
| 27 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : DSR 2022 SI No. 18.14 |
| 28 | 80 mm dia (18.14.4) |
| 29 | 150 mm dia (18.14.7) |
| 30 | Providing, fixing Testing &commissioning of 15mm dia quartzoid bulb type sprinkler of rating 68 degree centigrade with required accessories DSR 2022 SI No. (18.21.1)Pendent Type |
| 31 | Providing, installation, testing and commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed of FM approved complete as required. DSR 2022 SI No. 18.29 |
| 32 | Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. DSR 2022 Sl. No. 18.25 |
| 33 | 700 mm (18.25.1) |
| 34 | 1000 mm (18.25.2) |
| 35 | Fire Alarm SystemWorkSupplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card,minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. DSR 2022 SI No 17.2.1.2Two Loop Panel. |
| 36 | Supplying, installation, testing and commissioning of intelligent analog addressable photo thermal detector complete with mounting base complete as required. DSR 2022 SI No 17.2.4 |
| 37 | Supplying, installation, testing and commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. DSR 2022 SI No 17.2.5 |
| 38 | Supplying, installation, testing & commissioning of addressable manual call point complete as required. DSR 2022 SI No 17.2.14 |
| 39 | Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. DSR 2022 SI No 17.2.15 |
| 40 | Supplying, installation, testing & commissioning of addressable fire control module complete as required. DSR 2022 SI No 17.2.10 |
| 41 | Supplying, installation, testing & commissioning of fault isolator complete with base as required. DSR 2022 SI No 17.2.7 |
| 42 | Supplying, installation, testing and commissioning of intelligent addressable thermal detector with rate of rise cum fixed temperature thermistor complete with base complete as required. DSR 2022 SI No 17.2.9 |
| 43 | Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. DSR 2022 SI no. 17.5.1 |
| 44 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. PWD SOR 2018 SI No 501 |
| 45 | 16 Sqmm 4 Core |
| 46 | 35 Sqmm 3.5 Core |
| 47 | 95 Sqmm 3.5 Core |
| 48 | 120 Sqmm 3.5 Core |
| 49 | Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge. PWD SOR 2018 SI No 503 |
| 50 | 16 Sqmm 4 Core |
| 51 | 35 Sqmm 3.5 Core |
| 52 | 95 Sqmm 3.5 Core |
| 53 | 120 Sqmm 3.5 Core |
| 54 | Supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. complete in all respects as per direction of the Engineer incharge.PWD SOR 2018 SI No 504 |
| 55 | 16 Sqmm |
| 56 | 35 Sqmm |
| 57 | 50 Sqmm |
| 58 | 95 Sqmm |
| 59 | 120 Sqmm |
| 60 | Supply and burying of Safe Earthing Electrod T-19 Zn-Zinc Coated,Length 3000mm,outer pipe 48.4mmx3.2mm,inner pipe 26.9mm x 2.6 mm,terminal Dia 12mm,coating 80-100 micron filled with crystalline conductive mixture (CCm) having anti corrosive & conductive property with 50 Kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonary housing.(From electrode terminal to switch board,cost of 25x3 G.I. Strip will be extra) SOR 2018 Sl No 726 B |
| 61 | Supply and laying of 25mm x 3 mm G.I. strip from earth electrode directly in the ground as required complete in all respects. SOR 2018 Sl No 716 |
| 62 | Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules SOR 2018 Sl No 1136 |
| 63 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness DSR 2023 Sl No. 4.6.2 |
| 64 | Supply and fixing of self glow type exit sinage. (LED Type) (MR) |
| 65 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Capacity 5000 Ltrs Civil Dsr 2023 SI No-18.48 |
| 66 | Cost of minor repair @ repainting of necessary works after installation of fire figting works. MR |
| 67 | Dismantling aluminium/gypsum partitions, door, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material within 50 mtrs lead as directed by Engineer-in-charge Civil DSR 2023 15.57 |
| 68 | Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of size 595x595 mm of approved texture, design and pattern as per CPWD specification 2019, to be laid in true horizontal level suspended on interlocking medal T-Grid of hot galvanised iron section of 0.33 mm thick(galvanised @ 120 gram per sqm including both sides) comprising of main-T runner of size 24x38 mm of length 3000mm cross-T of size24x32 mm of length 1200 mm and secondary intermediate cross T of size 24x32 mm of length 600 mm to formgrid module of size (600x600 mm, suspended from ceiling using galvanised steel items (galvanising@80 gram per sqm) i.e 12x50 mm long dash fastener, 6 mm dia fully threaded hanger rod upto 1000 mm length and L shape level adjuster of size 72x25x25x1.6 mm fixed with grid and Z cleat of size 25x37x25x1.6 mm thick of precut hole on both 25 mm flanze to pierce into 12x50mm or even bigger size dash fastener if required, fixed with galvanised iron perimeter wall angle or size 24x24x0.4 mm of length 3000 mm to be fixed on periphery wall/partition with the help of plastic rawl plug at 450 mm centre to centre and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing as per direction of engineer in charge With 15 mm Tegular edged light weight calcium silicate false ceiling tiles Civil DSR 2023 26.22.1 |
| 69 | Cutting Holes of required size in brick masonary wall for fixing of Exhasut Fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc complete as per direction of Engineer-in-charge Civil DSR 2023 14.81 |
| 70 | Construction works of (2.0 Mtr) Wide M S Staircase :Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. DSR 2023 SI no. 2.6.1 |
| 71 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) DSR 2023 SI no. 4.1.8 |
| 72 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) DSR 2023 SI no. 5.1.2 |
| 73 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. DSR 2023 SI No. 5.22.6 |
| 74 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works DSR 2023 SI No. 10.25.2 |
| 75 | Supply of 48 mm thick Metal Fire Door of 120 minutes fire rating confirming to BS-476, Part22. part-II ; Fabricated with 2 nos 0.8 MM glavanized steel sheet sandwiching with proprietary fire resistant insulation (Honeycomb or materials in- between.The door frame are manufactured from 1.2 MM galvanized steel sheet pressed form to double rebate profile of size 100mm X 60mm. The door frame and door shutter are finished with powder coating of approved colour As per MR |
| 76 | Smoke Extraction System Work |
| 77 | Supply installation, testing and commissioning of long casing (GSS) Vane/Tube Axial flow type fans complete with aluminium alloy blades with aerofoil design, bird screen, flexible connection & gravity louvers at outlet. Motor shall be of 415 + 10% volts, 50 Hz. sound level at 3mt distance from fan outlet shall not be more than 90 db (A) (room condition). Capacity shall be as follows & as per detailed technical specification : Fans should be AMCA certified. Manufacturer shall submit :Certificate of conformity for 250 deg for 2 hours operation as per EN12101-3: 2002 or UL-705 issued by Internationally recognized independent fire laboratory should be submitted along with type test report.The type test report should clearly indicate the make of motor used during the testing and the same make/model of motor should be supplied by the fan manufacture at the site : RPM should not exceed 1450 However lower cfin upto 5000 CFM can be provided at 2850 RPM. Outlet velocity should not exceed 16 Emergency Operation20000 CFM @ 40mm static pressure MR |
| 78 | Addressable Relay Module for Integration with Smoke Exaust panel. MR |
| 79 | Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. Si no. 16.20 |
| 80 | Fire damper DSR 2022 Si no. 16.20.1 |
| 81 | Actuator DSR 2022 Si no. 16.20.2 |
| 82 | S/I/T/C of double layer canvas connection fore retardant cloth for the end connection of IDUs and Ventilation fan to reduce the vibration. It shallbe fire rated for at least 2 hrs. MR |
| 83 | Fan starter panel with Logic control panel with integration with fire alarm system for automated operation, with digital inputs from advance smoke detectors with DOL/ Star-delta starter, overload protection, phase protector, status LEDs - fault, Trip, power on / Off, suitable for accepting and processing command from fire alarm system or advance smoke detectors for automated fan operation in case of fire, offer status signal for FAS panel, with auto/ manual fan operation with motorised damper automated control in metallic enclosre wall / stand mountable, 415/3/50 power suply with display for status, signal readout, keypad/touchscreen for configuration password protection enable with emergency stop facility (one step) MR |
| 84 | Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. |
| 85 | Thickness 0.63 mm sheet DSR 2022 SI no. 16.12.2.1 |
| 86 | Thickness 0.80 mm sheet DSR 2022 Si no. 16.12.2.2 |
| 87 | Thickness 1.00 mm sheet DSR 2022 Si no. 16.12.2.3 |
| 88 | Thickness 1.25 mm sheet DSR 2022 Si no. 16.12.2.4 |
| 89 | Supplying & fixing of powder coated extruded aluminium Return Air /Exhaust Grills with louvers but without volume control dampers complete as per specifications and size & shape as per site requirement and approved design. DSR 2022 SI no. 16.16 Please Enable Macros to View BoQ information |