| 1 | SITC OF LT PANELS (Main Panel, APFC) as per SLDLT PanelsSupply Installation Testing & Commissioning of LT Panel vermin proof floor mouting, MS Channel base with botton and fabricated out of 2.00mm/1.6mm thick CRCA after proper sheet treament process of silent sheet. The bus bar of panel shall be of electrical grade high conductive aluminium alloy of appropriate cross section as per rating. the main bus bar shall run throughout the panel if rating as main incommer rating. this bus bar shall be supported by non hygrosocopic SMC/DMC bus bar support which shall support which shall be mounted on proper interval to ensure the bear the jerks of short circuit of 50kA for panel having ACB as incommer & 36kA for panel having MCCB incommers panel shall be constructed in fully segreated compartment desgin for each feeder as per 3b construction format, The Panel shall be completed in al respect as per IS 8623 part 2&3. There shall be seperate metering compartment for incommer metering & outgoing meteringAll Incommer Feeder shall be provided with multifunction metering along with phase indicator light and other associated componets such as CT control MCB Terminal Blcok etc and all outgoing feeder 100A & Above shall be provided in 3 Phase Ammeter along with phase indicating light and other associated components such as CT control MCB Terminal Block etc. Ther Feeder above shall be provided as accommouted all metering instruments shall be digital type & all indicating light shall be led type. Wiring shall be done from 1100V GRADE pvc Insulated copper flexible wire. All ACB shall be electrically operated drawout type with microprocessor based O/L S/C E/F release of breaking / with stand capacity (ICU/IC/S/ICW) 50kA or more. All MCCB shall be thermal magnetic/microprocessor with O/L & S/C protection along with required spreder and extended rotary handle with pad locking facility of breakcapacity (ICU/ICS) 36ka or more all MCB shall be thermal 10kA \\"C\\" Curve. Cubical type switchboard shall be CAT A/B OnlyMain LT Panel cum Synchronization Panel INCOMING:1 Nos ACB Incomer from 1250kVA CSS of ratings 2000AOUTGOING:800A ACB - 1 NOS , 200A MCCB - 6 NOS |
| 2 | 300kVAR APFC Panel with APFC Relay 16 Stage 3CT. The Incomer should be 630A, 3P, EDO, 50kA ACB and the panel mus be complete in all respect with relevant 3 Pole, 36kA, Microprocessor Release based MCCBs for relevant bank Outgoings, CTs, Digital Ammeter, Voltmeter, Indication lamps, MCBs, Timer, Relevant Capacitor Banks, 7% Detuned Reactors etc. |
| 3 | Supply & Fixing 800A TPN Sandwich type Aluminium bus bar trunking complete suitable for IP 54 protection with top cover plate of 1.6mm thick GI Sheet with suitable arrangement for fixing etc complete in all respect |
| 4 | Supply & Fixing of plug point 400A to 1000A TPN Sandwich type Aluminium bus truncking complete in all aspect |
| 5 | Supply & Fixing of Tap of Box 32A To 100A TPN for Sandwich type Aluminium bus truncking complete in all aspect |
| 6 | Supply & Fixing of Tap of Box 125A To 200A TPN for Sandwich type Aluminium bus truncking complete in all aspect |
| 7 | Supply & Fixing of Flange End 800A TPN for Sandwich type Aluminium bus truncking complete in all aspect |
| 8 | Supply & Fixing of End Cover 800A TPN for Sandwich type Aluminium bus truncking complete in all aspect |
| 9 | Supplying &laying of LT Cable 400 Sqmm 3.5 Core Aluminium Conductor XLPE insulated Armoured Cable confirimg IS: 7098 1100v grade at a depth of 750mm below ground level over a cusion of 75mm thick fine sand all around and protected with well burnt bricks on sides and top put across as dircetd by engineers in charges complete in all respect inculsing excavation and refilling. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. |
| 10 | Supplying & Laying and Fixing LT Cable 400 Sqmm 3.5 Core of one number PVC insulated and PVC sheathed/XLPE Power cable of 1.1 KV grade of following size on cable tray as required. |
| 11 | Supplying & making LT Cable 400 Sqmm 3.5 Core end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE Aluminium conductor Cable of 1.1KV grade as required. |
| 12 | Supplying & making LT Cable 400 Sqmm 3.5 Core straight through joint with heat shrinkable kit including ferrules & other jointing material for following size of PVC insulated and PVC sheathed /XLPE aluminium conductor Cable of 1.1KV grade as required. |
| 13 | Supplying & installing 750 MM X 75 MM X 2 MM CABLE Tray WITH COVER following size perofrated Hot Diped galvinsed iron cable tray (galvanisation thickness not less then 50 microns) with perforation not more then 17.5% in convenient sections, joined wth connectors,suspended/roof mounted with GI NUT BOLT & ETC required |
| 14 | Earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required. |
| 15 | Providing and fixing 25 mm x 5mm G.I. strip on surface or in recess for connections etc. as require |
| 16 | Providing and fixing earth bus of 50 mm x 5 mm copper strip on surface for connections etc. as required. Please Enable Macros to View BoQ information |