| Sl. No. | Item Description |
| 1 | Part A - Civil works |
| 2 | Empty boring for 525 to 600 mm dia.bored R.C.C.cast in situ piles including withdrawal of shell, removal of earth to a distance of 50 metres etc. complete. Spec :(As directed by Engineer in Charge) |
| 3 | Extra for Chiselling in hard rocks including removing and stacking the loose material and disposing the unserviceable materials as directed etc. complete. 600 mm dia |
| 4 | Providing placing and Driving in position 6 millimeter mild steel liner forR.C.C. Piles upto required depth with 12 mm thick mild steel cutting edge of 0.50 m length at bottom including fabricating cutting the mild steel sheet to required diameter and shape, welding thejointsanddrivingwith the help of requiredmachineries including all materials labours and lifts etc.completeasdirectedbytheEngineer incharge.Spec:(Asdirected by Engineer in Charge From 3.00 to 9.50 meter deep liner |
| 5 | Providing and laying cast insitu /Ready Mix Cement Concrete M-30 for boredpiles eachof load capacity and as per design and of 600 mm diameter or as directed placed through steel shells sunk to the required depth through all strata except rock excluding provision ofreinforcement as per detailed drawings and design approved by the Engineer-in-chargeincluding placingwith fully automaticmicro processor based PLCwith SCADA enabled reversibleDrumTypemixer/ concreteBatchmix plant (Panmixer)etc. complete.Withfineaggregate (Crushed sand VSI Grade) by tremie arrangements, compaction of concreteincluding chipping and dressing and withdrawal of shell etc. complete. (Excluding steel reinforcement) |
| 6 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 0.00 to 1.50 m.) By Manual Means |
| 7 | Excavation for foundation in hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 to 3.0m) By Manual Means |
| 8 | Chipping and dressing of the R.C.C. piles upto 0.60 meter including cleaning reinforcement and removal of dismantled materials upto adistance of 50 meter beyond the building area etc. for providing pile caps. Spec :(As directed by Engineer in Charge |
| 9 | Integrity testing of Pile using Low Strain/ Sonic Integrity Test/ Sonic Echo Test method in accordance with IS :14893 including surface preparation of pile top by removing soil, mud, dust & chipping lean concrete lumps etc. and use of computerised equipment and high skill trained personal for conducting the test & submission of results, all complete as per direction of Engineer-in-charge. |
| 10 | Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete.. |
| 11 | Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for foundation and bedding / steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.),with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 12 | Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap metal for R.C.C. pile caps as per detailed designs and drawings, including bailing out water manually, centering, formwork, laying/ pumping, compacting, finishing and curing etc. with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) complete (Excluding steel reinforcement) |
| 13 | Providing and laying Cast in situ/Ready Mix cement concrete M-30 of trap / granite/quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 14 | Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. |
| 15 | Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete |
| 16 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part- II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per One Square Metre of surface area covering ten years guarantee on bond paper. |
| 17 | Providing and laying Cast in situ/ReadyMix cement concrete M-30 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork,coverblocks, laying/ pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc.complete, (Excluding reinforcement and structural steel).with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Panmixer)etc.complete.With fine aggregate(Crushed sand VSI Grade) |
| 18 | Dismantling the R.C.C. Work 1:2:4 and sorting out the materials such as steel etc. as directed and stacking them within the specified lead as directed etc. complete. |
| 19 | Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc. |
| 20 | Providing and constructing masonry in Autoclaved Areaclaved ( Celluar) Concrete Block of aproved manufacturer confirming to IS 2185 Part III 1984 of size ( 625x240x225)mm in extra fine jointing mortar of fixoblock of in foundaions and plinth of inner walls/in plinth external walls including bailing out water,striking joints on unexposed faces,racking out joints on exposed faces and watering etc.complete |
| 21 | Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 22 | Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap / quartzite/granite /gneiss metal for R.C.C. Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying/pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 23 | Providing internal cement plaster 12 mm thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc.complete. |
| 24 | Providing internal cement plaster 12 mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces,in all positions including scaffolding and curing etc.(Sunkan Portion Ghutai Plaster) |
| 25 | Providing internal cement plaster 12 mm thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. (Dash Coat Plaster) |
| 26 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 Kilogram per cement bag curing the same for not less than 2 day sand keeping the surface of the base coat rough to receive the sand faced treatment 6to8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.Mortar will be machine mixed, volumetrically batched. |
| 27 | Providing and applying Kelox R 101 (Resin) + Kelox H 404 (Hardner) water misible epoxy of approved make for bonding old concrete to new moratr after mixing slowely in predefined ratio and applying by brush on the surface, when it is tacky then apply the moratr complete as per specification and as directed by engineer-in-charge. Work shall be executed by certified applicator only and work shall be guaranteed for 5 years and guarantee shall be provided on Rs. 500 /- stamp paper |
| 28 | Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete |
| 29 | Providing and fixing in position HCRM / CRS (Corrosion Resistant Steel) bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
| 30 | Supplying, Drilling/Cleaning hole and injecting chemical. Application to be designed separately for Rebars as Simply Supported, Moment or Splice Connection as per EC2/TR 023 or relevant tested and accepted rebar guidelines.The chemical should have ETA approval for seismic rebar as a minimum qualifying criterion.Drilling hole with double flute type drill bits or hollow drill bits to the required depth by rotary hammer drill,cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug.The installation and the setting instructions should be strictly followed as per the manufacturer‘s recommendations. The adequate diameter and embedment of rebars to be decided as per PROFIS Rebar Software & the report to be submitted to the project manager/ design engineer for approval.Scanning before drilling to be done to avoid hitting existing rebars. Re 500 -10 mm dia 200mm depth |
| 31 | Providing filling of Micro-concrete and 10 mm aggreagate ( 1:1) including scarificial leakproof MS shuttering includes the cost of hire charges of all machineries, barge, boat, cost of all tools and all labour charges etc.complete |
| 32 | Providing,Supplying,fabricating and fixing panel of aluminium composite panel cladding in approved shape made out of 4 mm thick ACP sheet material consisting of 3mm thick FR grade mineral core following NBC part IV Fire and life safety (having 2 hours fire resistance in accordance to ASTM E119-12 and BS476 part 6 and 7 class O)sandwitched between two aluminium sheets (each 0.5 mm thick of AA 5005/ AA 3105 grade) The aluminium composite panel cladding sheet shall be coil coated with kynar 500 based PVDF/Lumiflon based fluropolymer resin (having 70:30 ratio of PVDF and acrylic) coating of approved colour and sg=hade on top face and polymer (service) coating of bottom face as specified using stainless steel screws, nuts, bolts, washers,cleats,weather silicon sealent,backer rods etc .overall weight of the ACP shall not be less than 7.5 Kilogram/ One Square Metre) |
| 33 | Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete. |
| 34 | Providing and fixing factory made uPVC twin sash casement glazed window and door (White Colour) comprising of two shutters, one outward opening having glass and one inward opening having SS Mesh and integrated grill provision between two shutters. uPVC multi-chambered frame, sash, bugmesh sash and mullion (where ever required) extruded profiles with wall thickness of 2.3mm (+-0.2 mm) duly reinforced with G.I section 1.50 wherever required. uPVC window & door profile shall be made in India & shall conform to BS EN 12608 and other standards as mentioned below: S.No. Name of the test Test Method Specified Parameter 1 Tensile Impact Strength ISO 8256 - more than 700Kj/m2 2 Vicat Softening Temperature EN ISO – 306 Shall not be < 750C 3 Charpy Impact Strength EN ISO – 179-2 Shall not be < 20KJ/m2 4 Flexural Modulus Elasticity EN ISO – 178 Shall not be < 2200 N/mm2 5 Mean Breaking Stress for welded corner (a) For the tensile bending test EN – 514 Shall not be < 25 N/mm2 (b) For the compression bending test Shall not be < 30N/mm2 6 Heat Reversion Test IS:4985-2000 Shall not be > 2.0 % 7 Surface Spread of flame BS : 476 - Part 7 Classification 1 8 Ignitability Evaluation BS : 476 - Part 5 'P' Not easily ignitable 9 Tensile modulus ASTM D 638 Shall not be < 35 MPa 10 Shear Modulus ASTM D 732 Shall not be < 220 MPa 11 Tensile Strength EN ISO 527 Shall not be < 30 MPa. All corners of frame and sash will be fusion welded. Mullion shall be welded / screwed. EPDM / TPE Gasket shall be provided in all frame, sash & mullion, wherever necessary.Thereafter, 5 mm Float Annealed glass shall be provided in the sash with the help of uPVC glazing bead and hardware, i.e., friction hinge & single point handle (in window) & 3D Hinges & Multipoint Lock (in door) shall be provided. Window / Door shall be fixed to the wall with 100mm long and 8mm dia. Fasteners and complete in all respect as per direction of Engineer-In-Charge. uPVC Window and Door Profiles are warranted for a period of ten (10) years against non a)Twin Sash Casement Window frame of size 122 x 62 mm, sash 67 x 78 mm & bug-mesh sash of 42 x 84 mm. |
| 35 | Waterproofing treatment to new terrace by using chlorinated paraffinated talcum polyurethane (CPTP) elastomeric membrane as approved by Engineer in charge, followed by average 112mm thick brick bat coba covered with 40mm thick IPS. The procedure includes filling of cracks on the RCC slab with high performance polyurethane (liquid applied) membrane. Clean the entire surface thoroughly and over this prepared surface, apply a primer coat of high performance polyurethane (liquid applied) membrane as approved by Engineer in charge. Apply the primer by roller. Extend the coating to parapet walls including the top of parapet. Allow the primer coat to set for 24 hrs. After the primer coat is set, apply two coats of chlorinated paraffinated talcum polyurethane (CPTP) elastomeric membrane as approved by Engineer in charge on surface. Ensure that pinholes are touched up properly. While the second coat of high performance polyurethane (liquid applied) membrane is wet and tacky, sprinkle coarse sand over the surface to make it rough and provide mechanical key for further treatment. Provide and lay average 15 mm thk protective coat of CM in 1:4 over the surface and allow to set and cure. Provide and lay 112 mm thk BB coba in average thickness in cement mortar 1:5 with one pouch of thorough blend of special cements, aldehyde based polymers, shrinkage compensating agents - which is based on special cements, aldehyde based polymers, shrinkage compensating agents and selected sands having high abrasion resistance as approved by Engineer in charge per 50 Kg bag of cement and finishing with 40 mm thick IPS layer in M-20 CC by mixing one pouch of 330 grams of thorough blend of special cements, aldehyde based polymers, shrinkage compensating agents per 50 Kg bag of cement, including all leads, lifts and laid to proper slope to drain off water entirely preparing bell mouth including watta, beveled or champhered portion at the junction of parapet and work up to a height of 300 mm or as directed and including finishing the top layer of waterproofing treatment with false marking of 30 cm x 30 cm or as directed, curing and covering the whole treatment. The liquid membrane should have a track record of atleast 4 years in India & Gulf region and have atleast an 4 year track record in PWD. Single Component, Liquid Applied, chlorinated paraffinated talcum polyurethane (CPTP) elastomeric membrane should have following minimum properties: 1) Water Permeability |
| 36 | Providing/ fixing China Mosaic broken glazed tile chips on top of IPS (Random colour mix) in 1:7 mortar with grey cement float, joints filled with white cement, acid washed. (Lime to be added to mortar). (Main terrace only) |
| 37 | Clean the R.C.C. roof slab surface of all loose particles, dust, cement laitance etc. preferably done by using machine like device. Inspect for cracks/construction joints. Fill the cracks by Flexiroof PU of approved make & approved by Engineer in charge (This coating is to be protected by providing I.P.S. on top of it). Provide and apply a primer coat of Flexiroof PU Primer of approved make & approved by Engineer in charge on the cleaned RCC deck surface using a soft paint brush. Shake the container well and directly apply the primer by brush. Allow it to set for 30 - 45 mins. Provide and apply Flexiroof PU of approved make & approved by Engineer in charge by brush, roller or airless spray equipment. Apply at a rate of 1 Kilogram/Square Metre for the first coat evenly over the primer surface and allow to set for 12 hours. After ensuring that the first coat is set and cured, apply the second coat in similar manner at a rate of 0.5 Kilogram/Square Metre and allow to set. While the second coat is has reasonably hardened but still wet and tacky on surface, sprinkle sand over the surface to make it rough so as to provide mechanical key for the protective screed/IPS. Ensure that the sand does not gets embedded in the second coat and remains on the surface. Allow the two coats of Flexiroof PU of approved make & approved by Engineer in charge to air cure for 4-5 days before proceeding with the protective screed. This should be followed by application of compatible IPS of 25 MM thick waterproof bedding. The liquid membrane should have a track record of atleast 4 years in India & Gulf region and have atleast an 4 year track record in PWD. Single Component, Liquid Applied, Polyurethane Membrane should have following minimum properties: 1.Water permeability (DIN 1048): Nil as per DIN 1048 @ 7 bar of hydrostatic pressure. 2. Moisture permeability: < 0.4 g/m2/day 3. Accelerated Weathering (IS 101): 2000 hrs No cracking or blister formation. 4. Adhesion to concrete (ASTM D 1000): >21 Kilogram/cm2 (Concrete Fails) 5.Tensile Strength: > 2.0 MPa (ASTM D412) 6. Should not be water soluble or water dilutable |
| 38 | Providing and laying chequered tiles of approved quality of size 30 cm x 30 cm, confirming to corresponding I.S. for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. |
| 39 | Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. |
| 40 | Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete |
| 41 | Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete. |
| 42 | Providing and laying Antiskid Ceramic tiles of approved quality of size 30 cm x 30 cm and confirming to IS 15622-2006 (Group-B IIA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete |
| 43 | Providing and laying ceramic tiles having size 30 cm. x 60 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. |
| 44 | Providing and laying machine cut and mirror polished approved coloured ITALIAN MARBLE SLAB approved size, 20 mm +/- 2 mm thick of approved quality with approved qality, Italian marble inlays for flooring in required pattern on a bed of 1:4 cement mortar 25- 30 mm average thickness including neat cement float, filling joints with neat coloured cement slurry, curing, polishing and cleaning complete.( Basic rate of ITALIAN marble Rs. 6450/-per Sq.M) |
| 45 | Providing and fixing in position Gypsum board false ceiling with 12.5 mm thick Gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. |
| 46 | Providing and fixing 900mm high S.S.304 Grade Stainless steel railing with 40mm diameter and 1.5mm thick at top, 40mm diameter and 1.5mm thick vertical supports spaced at 1.5m center to center and 8mm thick toughened glass including fabricating ,fixtures, errecting , necessary welding , grinding , finishing, buffing to stainless steel pipe etc. complete |
| 47 | Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete |
| 48 | Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. |
| 49 | Waterproofing treatment to new terrace by using chlorinated paraffinated talcum polyurethane (CPTP) elastomeric membrane as approved by Engineer in charge, followed by average 112mm thick brick bat coba covered with 40mm thick IPS. The procedure includes filling of cracks on the RCC slab with high performance polyurethane (liquid applied) membrane. Clean the entire surface thoroughly and over this prepared surface, apply a primer coat of high performance polyurethane (liquid applied) membrane as approved by Engineer in charge. Apply the primer by roller. Extend the coating to parapet walls including the top of parapet. Allow the primer coat to set for 24 hrs. After the primer coat is set, apply two coats of chlorinated paraffinated talcum polyurethane (CPTP) elastomeric membrane as approved by Engineer in charge on surface. Ensure that pinholes are touched up properly. While the second coat of high performance polyurethane (liquid applied) membrane is wet and tacky, sprinkle coarse sand over the surface to make it rough and provide mechanical key for further treatment. Provide and lay average 15 mm thk protective coat of CM in 1:4 over the surface and allow to set and cure. Provide and lay 112 mm thk BB coba in average thickness in cement mortar 1:5 with one pouch of thorough blend of special cements, aldehyde based polymers, shrinkage compensating agents - which is based on special cements, aldehyde based polymers, shrinkage compensating agents and selected sands having high abrasion resistance as approved by Engineer in charge per 50 Kg bag of cement and finishing with 40 mm thick IPS layer in M-20 CC by mixing one pouch of 330 grams of thorough blend of special cements, aldehyde based polymers, shrinkage compensating agents per 50 Kg bag of cement, including all leads, lifts and laid to proper slope to drain off water entirely preparing bell mouth including watta, beveled or champhered portion at the junction of parapet and work up to a height of 300 mm or as directed and including finishing the top layer of waterproofing treatment with false marking of 30 cm x 30 cm or as directed, curing and covering the whole treatment. The liquid membrane should have a track record of atleast 4 years in India & Gulf region and have atleast an 4 year track record in PWD. Single Component, Liquid Applied, chlorinated paraffinated talcum polyurethane (CPTP) elastomeric membrane should have following minimum properties: 1) Water Permeability |
| 50 | Providing and fixing of BITUFLEX CLOSE CELL FOAM of size 30 mm x 30 mm in double layer in the expansion joints in R.C.C framed structure (at floor level / at terrace level / interior columns) for overlapping of closed cell foam joints, applying TP- 40 PRIMER on both the sides of concrete surface, filling the 25 mm x 25 mm gap with the POLYDEE-41 highly flexible sealant and covering the joint with Polydee-LM, 150 mm width in 2 coats etc. complete. Expansion joint treatment |
| 51 | Horizontal |
| 52 | Vertical |
| 53 | Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete. |
| 54 | Providing and fixing Table top white wash basin of size 120x635x405mm rubber plugs and brass chain, with pillar cock, C.P.Angular stop cock long thread, continental including S.S. bottle trap of approved make having necessary pipe connection up to theoutside face of the wall.etc complete as directed by Engineer in charge. |
| 55 | Providing and fixing divertor with overhead shower,shower arm,spout,hand shower with wall bracket having flow rate up to 12 liters/minutes of Jaquar/Cera/Hindware /Perryware or equivalent make including all necessary pipes,fittings etc.complete as directed by Engineer In Charge.( Make shall conform to manufacturer's Green product and shall got approved from the Engineer In Charge.) |
| 56 | Providing and fixing white european type wall-hung pan, of size 350mm x 355mm x 570 mm concealed flush tank with floor-mounting frame installing kit and drain pipe connection set for wall hung WC, with approved make square control plates including soil pipe, vent pipe upto the outside face of wall, 100mm dia C.I. plug bend inlet pipe all fittings,cutting & making good walls, floors etc. complete. |
| 57 | Providing and fixing C.P. 2 Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. |
| 58 | Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. |
| 59 | Providing and fixing 15 mm diameter PVC Aqua kraft type of approved make super jet spray with flange 2 in 1 faucet 1.50 metre long including all accessories etc complete |
| 60 | Providing and fixing C.P. sink cock with raised J\\" shaped swinging casted spout ofapproved make including necessary sockets/ union nut etc. complete.\\" |
| 61 | Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and One Number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. |
| 62 | Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 63 | Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 64 | Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete |
| 65 | Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete |
| 66 | Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete |
| 67 | Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. |
| 68 | Providing and fixing 10 cm PVC nahani trap with grating etc. complete. |
| 69 | Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight C. I. cover of 75Kilogramwith lid and frame fixed in cement concrete |
| 70 | Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and C.I. lid cover of 75Kilogramwith lid and frame fixed in cement concrete. |
| 71 | Providing , laying and fixing ,jointing Eco- drain 110 mm SN 8 Nu- Drain Upvc pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per I.S.15328 with fittings such a bends, tees, coupler, etc, jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated material etc. complete |
| 72 | Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap |
| 73 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : |
| 74 | 510x1040 mm bowl depth 250 mm each |
| 75 | Providing, fixing new G.M. gate valve I.S.I. Marked heavy duty with G.I. Assorted fitting(s) I.S.I. Marked such as tee, elbow, nipple, cupling, union, G.I. Clamp(s) and nails etc. and removing old valve (s) etc. |
| 76 | 25 mm dia. |
| 77 | 15 mm dia. |
| 78 | Providing and applying Royale Luxury Emulsion of approved make on internal wall surface as detailed below Scrapping for surface with emery paper and wipe clean for area. wall primer with brush by adding mineral turpentine oil by 8 to 10 % or water by 15 to 20% allowing to dry for 6 to 8 hoursAfter applying acrylic wall putty with appropriate prpportion of water of allow to dry for period of 4 to 6 hours of activity. Scrapping with emery paper and wipe clean Applying paints Royale Luxury emulsion 1st coat with brush water content water 40 to 45% or 65 to 70% by role Applying paints Royale luxury emulsion 2nd coat with brush with water content 40 to 45% or 65 to 70 % by roller. (With prior approval of S.E.) |
| 79 | Providing and applying Elastomeric, Anti carbonation, Anti corrosive, UV resistant, Solvent based Pure Aliphatic Acrylate System- MONOPOL 456 on the exterior faces of Buildings Protection against ION penetration, carbonation,UV radiations and wethering effect conforming to ASTM D 4541-02 having Electrochemical impedance of 107 Ω and achieving dry film thickness of minimum 200 microns in a primer coat followed by two top coats using brush or spray after complete cleaning & removal of oil, grease or loose particles from the surface etc. complete. |
| 80 | Providing and applying gypsum plaster ( with Gypsum material ) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete. |
| 81 | Providing and applying Texture plaster with finishing with texture material of approved make in 3 to 4 millimeter thickness on previously plastered surface, including Plaster Groove 6mm thickness or Tape Grooves 35 to 45 mm thickness or as required, in all position including preparing the surface, scaffolding etc. complete. |
| 82 | Filling voids/honeycomb with high pressure injection grouting of Polymer Cement Grout (10% of Polymer by Weight of Cement) |
| 83 | Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete |
| 84 | Preparation of lawn. Excavating the ground to required depth of 20 cm removing and conveying unwanted stuff to a required distance as directed, filling fresh garden soil and manure in excavated area in 3:1 proportion etc. complete |
| 85 | Providing and laying damp proof course 50 mm thick in M20 cement concrete layer and bitumen / using cement with waterproofing compound curing, formwork etc. complete. |
| 86 | Providing and fixing H.D.P container one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres |
| 87 | ACOUSTICAL WOODWOOL WALL PANELLING: Providing & fixing of 100% Natural Material- Magnesite (Hygroscopic & biologically sound binding agent) bonded woodwool Heradesign planks of 600Mm*1200Mm *25Mm thickness made out of wood wool fibre of width 1Mm Fiber thickness mixed with Natural water & Magnesite (NoCement) with open & smooth surface texture, Weight of panel to be 11.3 Kg/m2. A Completly harmless Envirenment & Human Friendly & also a disposable or recyclable Material & can last for more than 80 Years in building interiors As it has long lifespan & suitable for Indoor conditions with relative air humidity of upto 90%. Magnesite protects the wood cells against ageing & fungal attack. To achive upto NRC=1.00 it should be a clear gap of 200Mm from wall slab along with the backing of Mineral wool of 50mm thick with 64 kg/m3 density. Ecologically Sound Material with high mechanical strength with Crash test of 90Km/H with Ball Impact Test DIN18032 & EN13964 with flying colors & A sustainable material (PEFC & FSC Certified) along with EPD Certified Acc. to EN ISO 14025 (AUB-Envirenmental Product declaration). Manufacturing tolerance for nominal size: Length, Width & Thickness ± 1 mm, & In a Standard Climate of 23° C and 50% rel. humidity. FIXING & SUBSTRUCTURE: Impact Resitant According to DIN18023 or EN13964 to be Fixed on CD Sections Profile framework with Screw 9Pc/Panel & Centre Distance Support of 300Mm & Centre distance of Cross Profile would be at 600Mm & Main Profile at 900Mm CD Profile is made out of GI( Sections Profile 60/27/0.6Mm-0.6MmThick x 60Mm Width x 0.27Mm height). The Main Profile is in the legth of 3000Mm & to form a section of 600mm x 1200mm. Heradesign Superfine panels to be fixed on the wall with a minimum of 200Mm void or gap with Galvanized screws of length 50Mm & Dia 4.5Mm with a backing of Mineral Wool of density 64kg/m3 density (50mm thick).Colour Of Panels : NATURAL BEIGE, Can be Painted to the desired colour (Any- RAL, NCS or StoColor Shades) using water based color by Spray method prior to installation. FIRE CLASS as per EN 13501-1:B –s1, d0. Test Certificates to be submitted |
| 88 | PRIVIDING AND FIXING ACOUSTICAL FALSE CEILING WITH 0.7 NRC: Sierra Mineral Fibre Acoustical Suspended Ceiling System with 13mm thick Microlook Edge Tiles with 15mm face exposed grid. The tiles shall have smooth laminated salt pepper visual with Humidity Resistance (RH) of 95%, NRC 0.7 (Average value of Absorption Coefficient readings taken at 250 Hz, 500 Hz, 1000 Hz and 2000 Hz) as per ASTM C423 standard, CAC of 28db as per ASTM E1414, Light Reflectance ≥85% as per ASTM E1477, Thermal Conductivity λ = 0.037W/mK, Colour Global White, Fire Performance of class A2-s1, d0 according to EN 13501-1 with 13mm Microlook edge and 8mm drop in module size of 600 x 600mm. The scrim on the face of the tile shall be cleanable. The tiles shall be classified as ISO 14644-1 cleanroom class 5. It shall be suitable for Green Building application, with Recycled content of 60%. The tile shall have certifications from GRIHA and GreenPro thereby confirming that it is an environment friendly product. SUSPENSION: The tile shall be laid on 15 mm wide T - section flanges colour global white (matching to tile color) having roll formed double stroke rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm (all sections). The deflection loading of the system shall be 12.5 kg/m2 (as per standard installation layout mentioned below) and main beam tested as per ASTM C635 (Deflection limit less than L/360) with a deflection loading of 15kg/m. The end details of the cross tee shall be made of pre hardened steel and fixed to the ends of the cross tee to provide double locking between “cross tee to cross tee” and “cross tee to main beam”. All main beam to main beam and cross tee to cross tee connection shall have a pull out strength of more than 100kg. The T Sections shall be made of hot dipped galvanized steel of 90 gsm as per IS 277 (2003) and pre-painted steel with baked polyester paint with 0T bending capability. All border cross tee/main beam shall be levelled using perimeter fill. The Tile & Grid system used together shall carry a 10 year warranty against manufacturing defect and manufacturer shall provide a warranty certificate. The Tile & Grid shall have the manufacturers name embossed/printed on it. The supply shall be backed by a Manufacturing Test Certificate |
| 89 | TOTAL |
| 90 | Appointment of Architech and RCC designer for providing GFC drawing and RCC design of pile, pilecap, columns, slab and other structural members including interior design etc . Drawinga shall be vetted by IIT / VJTI or other equivalent institute |
| 91 | TOTAL A |
| 92 | Part B - Electrification works |
| 93 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formedwire armoured (strip) cable 1100 V, 3½ core 50 sq. mm. copper conductorcomplete erected with glands & lugs, on wall/ trusses/ pole or laid in providedtrench/ pipe as per specification no. CB-LT/CU |
| 94 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 4 core 25 sq. mm. copperconductor complete erected with glands & lugs, on wall/ trusses/ pole or laid inprovided trench/ pipe as per specification no. CB-LT/CU |
| 95 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copperconductor complete erected with glands & lugs, on wall/ trusses/ pole or laid inprovided trench/ pipe as per specification no. CB-LT/CU |
| 96 | Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. copperconductor complete erected with glands & lugs, on wall/ trusses/ pole or laid inprovided trench/ pipe as per specification no. CB-LT/CU |
| 97 | Supply, installation, testing & commissioning of distribution boards, 8 way VTPN type DB with door |
| 98 | IP 43 TPN Distribution Board with metal door (Box only) 8 Way ( 8 + 24 way) |
| 99 | 125A TPN MCCB |
| 100 | 63A 4P MCB |
| 101 | Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB 5-6-1 |
| 102 | Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic typewith 30/100/300 mA sensitivity with earth leakage trip indication complete as perspecification no. SW-RCCB/RCCB |
| 103 | 6A/20A SP MCB |
| 104 | Point wiring for light/bell concealed type in min 20 mm HMS PVC conduitwith 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch,earthing and required accessories as per specification no. WG-PW/CW |
| 105 | Secondary point wiring for additional light/bell point, concealed type in min20 mm PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires withrequired accessories as per specification no. WG-PW/CW |
| 106 | Point wiring for ceiling fan concealed type in min 20 mm HMS PVCconduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular typeswitch, earthing and required accessories as per specification no. WG-PW/CW |
| 107 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor wire in surface/ recessed medium class PVC conduit as required. Wiring for submains- medium class PVC- 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire in 20mm Conduit - R3-ME-3-1-b |
| 108 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor wire in surface/ recessed medium class PVC conduit as required. Wiring for submains- medium class PVC- 2 X 4 sq. mm + 1 X 4 sq. mm earth wire in 25mm Conduit - R3-ME-3-1-c |
| 109 | Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. With necessary accessories in wall/floor with chiselling appropriately. WG-MA/CC. 1-1-9 |
| 110 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. 1-6-35 |
| 111 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. 1-6-36 |
| 112 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 4 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. 1-6-37 |
| 113 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. 1-6-38 |
| 114 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. 1-6-39 |
| 115 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. 1-6-40 |
| 116 | Supplying and erecting exhaust fan heavy duty 230 V A.C. 50 cycles 450 mm.900 RPM complete erected in position as per specification no. FG-FN/EXF |
| 117 | Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. 1-6-1 |
| 118 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter on provided plate and box with wiring connections complete. |
| 119 | Supplying and erecting modular type 3 pin 6/16A multi socket with safety shutter on provided plate and box with wiring connections complete. |
| 120 | Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete1-6-2 |
| 121 | 20Amp SP MCB with 20A ray roll type, 3pin plug & socket withcap & chain etc. - R3-ME-1-19-d |
| 122 | Supplying and erecting PVC box trunking of size 100x50 mm. with accessories on wall/ceiling as per specification No: WG-MA/BOX . 1-2-14 |
| 123 | Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles1200 mm, Max. Energy Consumption of 28W having service ratio (CMM/W)of Min. 8 , PF>0.9, THD<10% with IR remote control, Temperature Rise ofMax. 40 deg.C, having external mounted control PCB completely erected inposition as per specification no. FG-FN/CF |
| 124 | Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225mm. 1400 RPM with condenser complete erected in position with necessarymaterials. Fan motor with moisture proof treatment and ‘E’ class insulation. |
| 125 | Supplying and erecting LED square / circular Max. 11 W downlighter/Panel Light having pressure die-cast aluminium housing, polystyrenediffuser having system lumens output of Min. 1200 Lumens, min. efficacy of110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. rippleof 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mountingarrangement with board for surface type or spring loaded mounting clipscomplete with 3 years warranty. |
| 126 | Supplying and erecting LED square / circular Max. 14 W downlighter/Panel Light having pressure die-cast aluminium housing, polystyrenediffuser having system lumens output of Min. 1500 Lumens, min. efficacy of110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. rippleof 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mountingarrangement with board for surface type or spring loaded mounting clipscomplete with 3 years warranty. |
| 127 | Supplying and erecting LED square / circular Max. 25 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 2-1-6 |
| 128 | Supplying & erecting inverter LED batten 20W tube light fitting withpolycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600mA Lithium ion Battery with charging time of 8-10 Hours and backup time ofMin. 3 Hrs with minimum 25% of initial Watts having luminous efficacy of 100lumen/watt, CRI>80, CCT of 6500K and THD<=20 % having useful life ofminimum 25000 Hrs with over heat protection with minimum 2 years as perspecification No. FG-IDF/LED. |
| 129 | Supplying and erecting LED Strip light 5m Length Max. 95 W IP20 classhaving minimum lumens output of 1600 Lumens/m, min. efficacy of 90lumen/W, CRI>80, CCT upto 5000K, Beam Angle of 110 deg., THD<10%, p.f.>0.95, operating range of 230-270V, Life class of 30,000 Hrs. at L70B50including driver with 1 year warranty. |
| 130 | Supplying and erecting bulk head LED fitting max. 10W with high transitivitydiffuser with system lumens output of min. 1100 lumens, min. efficacy of 110lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f.>0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life classof 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVCBlock / wooden board with 3 years warranty. |
| 131 | Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cmcomplete with all materials, testing & recording the results as per specification no.EA-EP |
| 132 | Supplying and erecting GI wire of high purity of required sizes used for earthingor any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/conduit with screws complete. |
| 133 | Supplying and erecting integrated LED flood light fitting Max. 100W IP65 &IK07 class having pressure die-cast aluminium housing, having system lumensoutput of Min. 12000 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCTupto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surgeprotection of 4 kV, Life class of 50,000 Hrs at L70B50 including driver with Ushaped bracket with minimum 2 Years warranty as per specification No. FGODF/FL. |
| 134 | SITC of IP67 linear surface-mounted LED luminaire. Extruded H shapedaluminum profile. |
| 135 | Supplying and laying (including excavation of suitable width & depth up to 90cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPEfor enclosing cable below ground/road surface, complete. |
| 136 | Supplying and laying (including excavation of suitable width & depth up to 90cm) 90 mm outside dia. double wall corrugated pipes (DWC) of HDPEfor enclosing cable below ground/road surface, complete. |
| 137 | Supplying and erecting electronic type cordless call bell erected on T.W.board having portable bell push working on 9V D.C. battery and (effectiverange upto 45 meter) bell on 250 V A.C. supply. |
| 138 | Supplying & erecting conventional spike type air termination suitable to carrylightning stroke made up of heavy gauge 40 mm dia copper pipe of standardlength with 5 Nos. copper spikes fixed on copper ball as air terminals dulythreaded in copper pipe erected on provided foundation complete. |
| 139 | Supplying and erecting GI strip of high purity required size used for earthing onwall and/or any other purpose with necessary GI clamps fixed on wall paintedwith bituminous paint with joints required. As per specification no EA-EP. |
| 140 | Total B Please Enable Macros to View BoQ information |