| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 30-04-2026 | Amendment01 | BOQ | 20-05-2026 |
| Sl. No. | Item Description |
| 1 | Taking down chowkhats with shutter (without taking off shutters from the frame) area not exc. 1.50 Sqm each complete all as specified and directed. |
| 2 | Taking down chowkhats with shutter (without taking off shutters from the frame) area exc. 1.50 Sqm but n.exc 4.00 sqm each complete all as specified and directed. |
| 3 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thick above or below ground level complete all as specified and directed. |
| 4 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish off premises complete all as specified and directed. |
| 5 | Demolition of brick work or stone/boulders masonary, built in cement mortor including all quoins, arches pillars, etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed. |
| 6 | Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed. |
| 7 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc, laid, bedded, jointed and pointed in any mortar complete all as specified and directed by Engineer-in-charge. |
| 8 | Dismantling brick/concrete tiles any size etc including existing roof treatment of any thickness complete all as specified and directed. |
| 9 | S&F Pressed steel frame for doors of size 125 x 60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete all as specified and directed. |
| 10 | M&L for cement concrete type C-1, (1:3:6) using 20mm graded aggregate as in bed block or filling of chowkhats including necessary form work complete all as specified and directed. |
| 11 | M&L 35mm thick factory made glazed and skeleton shutters of 2nd class HW with partially panel shutter open rebated and prepared to receive glass / gauze etc edges or framing plain chamfered or rounded fitted with cut or mitred beads for securing glass etc as specified in SSR Part-1 section 8.24 (a) complete all as specified and directed. |
| 12 | S&F 35mm thick plain framed panelled door shutter, factory made (any number of panels) of 2nd class hard wood with lock rail and panels of 9mm thick BWP commercial ply or 12mm thick veneered particle board with commercial veneering on both faces including 2nd class hard wood kail beading 20mm wide tapering from 10mm to 5 mm on one side of shutter & fitted to chowkhats. The size of rail and style shall be as per IS –1003 (Part-I) (wood shall be kiln seasoned and chemically pressure treated) complete all as specified and directed. |
| 13 | S&F Factory made box type steel windows with hung shutters both glazed and guaged shutter frame 60x25 mm ERW hollow 'P' section with wall thickness not less than 1mm fixed to pressed steel frame 120mm x 70 mm x 1.6mm thick including fixing glazed portion, iron grills 8mm square MS bar hunges with steel handle and fitting, lugs etc, including one shop coat of primer complete all as specified and directed. |
| 14 | M&L 4mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane including painting / oiling to new putty to match with the existing/new surfaces, complete all as specified and as directed. |
| 15 | S&F 4mm thick figured glass in glazing to aluminium door, window & partition including pad panes complete all as specified and directed by Engineer-in-Charge. |
| 16 | S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or stainless steel wire staples complete all as specified and directed by Engineer-in-Charge. |
| 17 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headedcounter sunk S.S screws, all as per direction of Engineer In- Charge. Note: stainless steel butt hinges shall be paid separately. |
| 18 | S&F factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall beacceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 19 | S&F 150mm stainless steel barrel tower bolts of extruded section and fixed complete all as specified and directed. |
| 20 | S&F 150mm long stainless steel handles, cast type complete all as specified and directed. |
| 21 | S&F 300mm stainless steel sliding door bolts, bolt type with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed. |
| 22 | S&F 140mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed. |
| 23 | S&F 100mm size stainless steel hinges complete all as specified and directed. |
| 24 | M&L for preparation of new wooden or wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer-in-Charge. |
| 25 | M&L Non skid coloured ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match with and including 15mm thick screed bed in cement mortar (1:6) for laying floor finishes complete all as specified and as directed. |
| 26 | M&L for glazed ceramic tiles (coloured) 450mm x 300mm x 7mm thick on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering in cement & sand mortar (1:4) including necesary cutting as per site requirment complete all as specified and directed by Engineer-in-charge. |
| 27 | M&L for non skid ceramic coloured tiles 7 to 8mm thick (square / rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar (1:4) complete all as specified and directed by Engineer-in-charge. |
| 28 | M&L for non skid ceramic coloured tiles 7 to 8mm thick (square / rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar (1:4) complete all as specified and directed by Engineer-in-charge. |
| 29 | M&L for 25mm thick PCC (1:2:4) type B-0 using 25mm graded stone aggregate) as in sub base of floor and leveling course complete all as specified and directed. |
| 30 | M&L for Brick work with sub class ‘B’ old size burnt bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-charge. |
| 31 | M&L for rendering 15 mm thick in CM 1:4 including water proofing compound on fair face of brick or concrete surface, finished even and fair without using extra cement complete all as specified and directed.Note:- WPC shall be measured and paid saperately. |
| 32 | Supply only liquid water proofing compound of approved complete all as specified and directed. |
| 33 | M&L for rendering 15mm thick on other than fair faces of brick work or concrete surfaces in cement mortar (1:6) and finished surface fair and even complete all as specified and as directed. |
| 34 | M&L for rendering 5mm thick in CM (1:4) as on ceiling complete all as specified and directed. |
| 35 | M&L for preparation of new plastered surface of wall and applying two coats of acrylic distemper over one coat of primer over 1mm thick wall care putty complete all as specified and directed. |
| 36 | M&L for preparartion of new plastered surfaces of walls and applying two coats cement base paint on walls complete all as specified and directed. |
| 37 | M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed. |
| 38 | M&L for applying a coat of two component elastomeric acrylic polymer modified cementitious water proofing coating, having properties of 80 % elongation as per ASTM D412, resisting 5 bars hyrostatic pressure as per DIN 1048, reduction to rapid chloride shall be 70 as per DIN 1048, crack bridging upto 1.2mm as per ASTM 4548.5. The mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing, etc., complete as per manufacturers specifications and sprinkle sand at 10-15 gram per sqft for better grip with plaster complete all as specified and directed. |
| 39 | M & L for complete removal of existing treatment and preparartion of old surfaces of walls and applying two coats of cement based paint on walls etc complete all as specified and as directed. |
| 40 | M&L for complete removal of existing treatment and preparation of old surface of walls and applying two coat of distemper acrylic emulsion distemper on wall incl applying a coat of wall care putty to achieve smooth finish to wall etc complete all as specified and directed. |
| 41 | M&L for preparation of old decorated, plastered or pointed surfaces of ceiling by brooming down or steel wire brushing, scrapping down smoke soot moulds, moss and efflorescent, salts and treating oil & greasy spots etc and applying two coat of white wash complete all as specified & directed by Engineer-in-Charge. |
| 42 | Taking up or down 15mm dia, steel tubing & connections including cleaning for refixing or removal to store complete all as specified and directed by Engineer-in-Charge. |
| 43 | Taking up or down 20mm dia, steel tubing & connections including cleaning for refixing or removal to store complete all as specified and directed by Engineer-in-Charge. |
| 44 | S&F 15 mm dia steel water tubing, galvanized, medium grade, with all fittings, fixed to walls and ceiling or in floor complete all as specified and directed by Engineer-in-Charge. |
| 45 | S&F 20 mm dia steel water tubing, galvanized, medium grade, with all fittings, fixed to walls and ceiling or in floor complete all as specified and directed by Engineer-in-Charge |
| 46 | S&F PVC (SWR) 110 mm bore pipes single socketed in any length with rubber ring joints laid in trenches or fixed to wall complete including taking down old unserviceable PVC pipe with fittings complete all as specified and directed. |
| 47 | S&F PVC (SWR) 75 mm bore pipes single socketed in any length with rubber ring joints laid in trenches or fixed to wall complete including taking down old unserviceable PVC pipe with fittings complete all as specified and directed. |
| 48 | S&F PVC (SWR) 75mm bore bends any radius complete all as specified and directed. |
| 49 | S&F PVC (SWR) 110mm bore bends any radius complete all as specified and directed. |
| 50 | S&F 110mm PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and as directed. |
| 51 | S&F 110mm bore PVC (SWR) junction, double (double T) equal or unequal complete all as specified and directed by Engineer-in-Charge. |
| 52 | S&F 75mm PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and as directed. |
| 53 | S&F 75mm bore PVC (SWR) junction, double (double T) equal or unequal complete all as specified and directed by Engineer-in-Charge. |
| 54 | S&F PVC (SWR) 110mm bore bends any radius with access door complete all as specified and directed. |
| 55 | S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed by Engineer-in-Charge. |
| 56 | S&F in repair CP Health faucet with stand fixed on wall in CP hose pipe 1 mtr length and stainless steel screw as approve complete all as specified and directed by Eng-in-charge. |
| 57 | S&F in repair 15 mm bore bib tap, long body, cast copper alloy, chromium plated, long body, fancy type screwed down and screwed for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-charge. |
| 58 | S&F in repair 15mm bore CP angle valve, fancy type, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed by Engineer-in-charge. |
| 59 | S&F in repairs, vitreous China wash hand basin, white, flat back size 550 x 400mm including 15mm dia, 450 mm long HDPE PVC connection, 750 mm long 32mm bore HDPE waste down pipe including CI brackets complete all as specified and directed. |
| 60 | S&F in repair 15mm dia stop cock cast copper alloy, fancy type with, chromium plated long shank and cup (concealed type) with crutch or butterfly handle screwed down high pressure, screwed both ends for iron pipe complete all as specified & directed by Engineer-in-charge. |
| 61 | S&F in repair chromium plated shower rose with shower arm or without swivel joints including fixing to steel pipe of 100 mm size complete all as specified and directed by Eng-in-charge. |
| 62 | S&F in repair PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and as directed. |
| 63 | S&F pillar taps fancy type, (swan neck) of 15 mm dia, cast copper alloy, with capstan heads, with chromium plated, screwed down high pressure with or without lettered 'hot' or cold with long screwed shanks and fly nuts, screwed for iron pipe and fixed. |
| 64 | S&F in repair PVC mirror cabinet size 350X450mm of standard size fixed to wall with PVC sleeves and steel screws complete all as specified and directed. |
| 65 | S&F in repairs vitreous china wash down, water closet pan (pedestal pattern), white including fixing bolts and connection to flush pipe and drain out going pipe and closet seat cover black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, CP jet including PVC connection complete all as specified and directed. |
| 66 | S & F in repairs PVC 10 ltrs syphonic action type flushing cistern, low level with inlet, ball valve, float and handle including brackets, flush pipe of PVC 32mm bore and connection to WC pan complete all as specified and directed. |
| 67 | S&F in repair brass chromium plated tubular towel rail 20mm dia; 'D' type, 600mm long between flanges fixed to plug with chromium plated brass screws including wooden or plastic cleat complete all as specified and directed by Engineer-in-Charge. |
| 68 | S&F in repairs low density poly ethylene waste pipes (LDPE) of 32mm bore complete suitable for wash basins, complete all as specified and directed. |
| 69 | S&F in repair stainless steel grating 100mm bore size fixed with white cement complete all as specified and directed by Eng-in-charge. |
| 70 | S &F for rotational moulded polythelene water tanks triple layer white colour (cylindrical vertical with closed top) hoisted and fixed in position for 750 ltr. storage capacity including disconnecting and taking down old unserviceable tanks, ball valve and nipple complete all as specified and directed. |
| 71 | S&F 20 mm dia ball brass valve high pressure with polythene float and fly nuts complete screwed for iron pipes or brass ferrule and fixed complete all as specified and directed. |
| 72 | S&F GI nipple 20mm dia, 150mm long with ISI mark complete all as specified and directed by Eng-in-charge. |
| 73 | S&F in repairs curtain rod, stainless steel of 25mm dia with fixing brackets stop rollers etc fix complete all as specified and directed. |
| 74 | S&F in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheeet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed. |
| 75 | M&L Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth |
| 76 | M&L for 75 mm thick PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregate as in plinth protection, finished fair and even complete all as specified and directed by Engineer-in-charge.Note :- Plinth protection shall be laid to slope (1 in 30) in bays not exceeding 3 metre in length and joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with sealing compound grade B. Cost of ceiling compund is included in the unit rate of this item complete all as spcified and directed. |
| 77 | Dismantling loose/disintegrated portion of RCC Chajjas, bands, shelves, beams, coloumn or slab and similar work including support if required and stitching of cracks with MS U clamps of 8mm dia @ 150mm c/c with inserting concrate block strecthner with cement mortar (1:3) mixed with adhesive chemical (polymer based) and reinforced with PVC chicken mash formwork including where ever required and finished with 10mm thick plastering in CM (1:4) finished even & smooth without using extra cement including preparation of surfaces to receive finishes complete all as specified and directed. |
| 78 | M&L for cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) as in lintels upto 1.5 metre clear span, cills, steps, siesmic and other similar bands, plinth courses, string courses, lacing courses, coping, parapets and railing upto 60cm height, copings bed block,roof kerbs or mud stops, kerb stone, kneelers, apex stones, bed plates, surface channels and drains, benching, water troughs and the like including weathering, slightly rounded or chamfered angles and throatings etc.including necessary form work complete all as specified and directed by Engineer-in-Charge. |
| 79 | M&L for water proofing treatment with APP modified bituminous membrane 3mm thick consisting of the following for RCC roof :-(a) Cleaning palstered roof surfaces and applying a coat of oxidised bitumen based solvented primer a@ 0.3Kg /Sqm of approved make on top of dry surface of RCC roof complete all as specified and directed.(b) M&L for APP modified polymeric water proofing membrance 3mm thick weight not less than 3.0 Kg/Sqm with non woven polyster core of approved make applied by heating one surface of membrane with LPG torch with lap of 100mm and the overlap shall be sealed by flame complete all as specified and directed. |
| 80 | S&F precast hydraulically pressed PCC tiles of size 30cm x 30cm x 20mm thick laid over and including screed bed 15mm thick in CM (1:4) set and jointed in neat cement slurry and pointed in CM (1:3) mixed with WPC of approved make in screed bed and pointing on roof complete all as specified and directed. |
| 81 | M&L for machine cut kota stone slab flooring 18-20 mm thick over cement screed base laid and jointed with pigment to match the shade of the slab including rubbing and polishing including screed bed and bedding layer of mortar 20 mm thick in CM (1:4) for laying floor finishes size complete all as specified and directed. |
| 82 | M&L for machine cut kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar laid over and including cement plaster 15 mm thick in CM (1:3) laid and jointed with pigment to match the shade of slab including rubbing and polishing complete all as specified and directed. |
| 83 | M&L for mirror polishing on marble / granite / kota stone / stone work whereever required to give high gloss finish complete all as specified and directed. |
| 84 | M&L for 100 mm thick Cement concrete type D-2, (1:4:8) using 40 mm graded stone aggregate as in sub base complete all as specified and directed. |
| 85 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar (1:3) including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete all as specified and directed. |
| 86 | M&L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed by Engineer-in-Charge. |
| 87 | Taking down surface / concealed copper / aluminium point wiring (light, bell, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, lamp holders, pendants, sockets, regulators, tubelight fittings etc and making good disturbed surfaces with plaster on walls, floors etc complete all as specified and directed. |
| 88 | M&L for Point wiring complete with 1.5 sqmm single core FRLSH PVC insulated cable with multi stranded copper condutor in and including PVC conduit 20mm dia and thickness not less than 1.5mm, ISI marked with all accessories for surface or concealed conduit as directed at site incl chase cutting for one light / fan point / bell point / fan point / exhaust fan controlled by one one way switch including MS sheet sunken box concealed on wall duly painted inside and outside with one coat of red oxide primer and two coats of black bituminous paint with 3mm thick hylum brand bakelite sheet cover for fixing switches, sockets, regulators etc. alongwith 1.5 sqmm multi stranded FRLSH, PVC insulated copper cable as continuous earth connected to common earth and earth dolly including making good the disturbed surfaces complete all as specified and as directed. |
| 89 | All as per serial item No. 88.00 here-in-before but for One 3 pin 5 Amp socket outlet on independent board. |
| 90 | All as per serial item No. 88.00 here-in-before but for One 5 pin 5 Amp socket outlet on the same board with other switches. |
| 91 | All as per Sl item No 88.00 above herein before but for one bell point controlled by one bell push. |
| 92 | M&L for point wiring with 2.5 sqmm PVC insulated, unsheathed FRLSH multistrand copper conductor cable 1100 volts grade drawn into and including rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all and including conduit fittings and fixing accessories 1.2mm thick sunken anodised pressed steel terminal boxes with 3.0 mm thick hylam sheet cover for mounting switches, socket etc including 2.5 Sqmm FRLSH multistrand copper conductor cable as continuous earth wire complete for one socket 16 Amp socket outlet controlled by one switch on independent board.complete all as specified and directed. |
| 93 | S & F bell ding dong AC 240 volts, single phase complete all as specified and directed. |
| 94 | S & F modular bell push, 6 Amp 240 volt one module complete all as specified and directed. |
| 95 | S & F modular type 6A one way SP switch 1 module confirming to IS: 3854-1997 with finger proof terminal complete all as specified and directed. |
| 96 | S & F modular type 2/3 pin 6 Amps socket 2 module conforming to IS: 1293-2005 complete all as specified and directed. |
| 97 | S & F modular type 16 A one way SP switch 1 module confirming to IS: 3854-1997 with fingure proof terminal complete all as specified and directed. |
| 98 | S & F modular type 2/3 pin 16 Amps socket 2 module conforming to IS: 1293-2005 complete all as specified and directed. |
| 99 | S & F modular type 3/5 pin socket with one Single pole MCB 20 Amp 230 volt including concealing in wall suitable for AC and domestic appliances complete all as specified and directed. |
| 100 | S & F modular type 120W step fan regulator of 2 module size conformng to IS: 11037-1984 complete all as specified and directed. |
| 101 | S&F ceiling rose 63x30 mm three terminal, polycorbonate body complete all as specified and directed. |
| 102 | S&Fin repair LED wall light, stainless steel, brushed nickel, frosted glass with base cap B22, height 235mm, length 120mm single phase 220 V complete all as specified and directed. |
| 103 | S&F in replacement LED (1.2m) smartbrite extra batten made of CRCA sheet housing provided for efficient heat dissipation with a PC glossy diffuser duly prewired connection having a normal system lumen output of 2000 lumen/20 watt at a minimum system efficacy of 2000 lumen per 20 watt and total power consumption not more than 20 watt including driver of capacity 10 KA. It has a rated system life time of 25000 burning hours at L70 and should have a colour temperature of 6500 K, CRI>80, THD<10\\"%\\" AND PF>0.95 complete all as specified and directed. |
| 104 | S&F in replacement LED (0.6m) smartbrite extra batten made of CRCA sheet housing provided for efficient heat dissipation with a PC glossy diffuser duly prewired connection having a normal system lumen output of 1150 lumen/10 watt at a minimum system efficacy of 1150 lumen per 10 watt and total power consumption not more than 10 watt including driver of capacity 5 KA. It has a rated system life time of 25000 burning hours at L70 and should have a colour temperature of 6500 K, CRI>80, THD<10\\"%\\" AND PF>0.95 complete all as specified and directed. |
| 105 | Supply & fixing in replacement security light with LED street light, 35 Watt, IP - 66, Impact resistance - IK07, colour temp- 5700 K, Class-I in pressure die-cast aluminium alloy for housing (heat sink) for effective thermal management, sturdiness, excellent corrosion resistant, separate optical and control gear compartment & top opening for easy maintenance. Polyster powder coated grey after phosphochromate treatment High efficiency long life LED modules with SMD LED package mounted on MCPCB. Lumen efficacy of LED >110 lm/W with PC lens to ensure better uniformity of light distribution. Powered by Built-in, Potted electronic LED driver (SMPS based constant current supply) with lower THD, Output Open Circuit protection, Phase to Phase protection, Over Voltage protection, Surge Voltage protection upto 10 kV with external SPD & other safety tests as per IS 15885 Part-2/ Sec13 alongwith arm with single arm bracket OD 58 mm (max) with clamp, nut, bolts etc mounted on wall complete in all respect complete all as specified and directed. |
| 106 | S&F in repair 10W integrated LED bulk head luminaire environment friendly, ultra modern, energy saving, surface mounted decorative oval bulk head with LED light, complete all as specified and directed. |
| 107 | M & L concealed sub main wiring with 2 runs of 4 sqmm main wire along with 1 run of 4 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC conduit (medium grade) with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the same including taking down old unserviceable cable complete all as specified by Engr- in- Charge.NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length. |
| 108 | M & L concealed sub main wiring with 2 runs of 6 sqmm main wire along with 1 run of 6 sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC conduit (medium grade) with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the same including taking down old unserviceable cable complete all as specified by Engr- in- Charge.NOTE:- Two runs of main copper conductor, one run of earth wire and one run of PVC conduit shall be measured as one unit length. |
| 109 | Supply & fixing in replacement sheet metal enclosure MCB distribution board Single Pole & Neutral 240 volts 8 way with 200 Amp rated bus bar double door with isolated Neutral bar & shrounded bus bar IP-42 having door earthing complete all as specified and directed. |
| 110 | Supply & fixing in replacement of MCB Single Pole Neutral 240 volt any rating from 32 to 63 amps, C series with rupturing capacity 10 KA complete all as specified and directed. |
| 111 | Supply & fixing in replacement of MCB single pole 240 volt any rating from 6 to 32 amps, C series with rupturing capacity 10 KA complete all as specified and directed. |
| 112 | S&F in repalcement Exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230 V, 5 Hz, RPM 1200, copper winding of sweep 300mm complete all as specified and directed.Note : Old unserviceable exhaust fan shall be deposited in AGE E/M store yard. |
| 113 | M&L for in replacement earthing with galvanised steel earth plate elctrode 600x600x6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr below GL) with the toop edge of the plate not less than 1.5 mtr below the normal group level connected to GI earth srtip of size 25x4mm thick soldered and riveted to earth plate,GI earth strip will be protected by using 50mm bore GI pipe (light grade) earth plate to equipment and watering pipe 20mm bore (light grade) and chamber/pit in PCC(1:3:6) type C1 using 20mm graded stone aggregate with precast RCC pit cover 50mm thick in (1:2:4) type B1 using 20mm graded stone aggregate reinforced with 8mm dia MS TMT bar at 80mm c/c both way with lifting hook made out of 8mm dia TMT bar duly embedded in RCC cover in lieu of CI pit cover with angle iron frame including excavation and earth work and removal of surplus soil complete all as shown in electrical plase No.3 of SSR Part-I and as specified including earth plate surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers of charcoal dust, common salt complete and earth lead connected to earthing test point/main board all as specified and testing of earthing complete all as specified & directed. |
| 114 | Supply and fixing in replacement of burnt conventional fans with BLDC ceiling fans, 5 star rated by Bureau of energy with service value of not less than 6.40, (30W±10%) with or without remote, with rated speed 350 Rev per min, air delivery 220 Cum/min complete with blades, down rods, electronic regulator and accessories, 230 volt, 1200 mm sweep, suitable for single phase supply complete all as specified and directed. Note : Old unserviceable ceiling fan shall be deposited in AGE E/M store yard. |
| 115 | Supply and fixing in repair factory made sheet metal enclosure MCB DB TPN 4 way with 200 amps rated bus bar 240 volts double door with isolated neutral bar and shrounded bus bar IP protection 43 IK-09 protection having door earthing complete all as specified and directed. |
| 116 | Supply and fixing in repair 125 Amp 4 Pole MCB isolator, 415 Volts with breaking capacity 36 KA complete all as specified and directed. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail