| 1 | SCHEDULE `A' PART - I (Building / Structure Works) is not prepriced by MES and prepriced rates indicates 0.00 under column 5 signifies this fact only. |
| 2 | Design and construction of three storey (G+2) hybrid structure with LGSF Technology for SNCOs Mess and Living Accn for JWOs and Sgts all as shown on drawings and as specified. The following specifications including all facilities as per Design Basis Report shall also be followed:- |
| 3 | Foundation RCC isolated footing /raft footing foundation shall be done as per design and soil testing report. Hybrid Building Structure:Hybrid Solution using LGSF 550 MPA & 3 Plate - 345 MPA TATA or equivalent make steel designed in accordance with IS code - stadd & Framecad software duly painted with primer and paint – total 80 DFT.The structure to be duly fabricated in factory, site welding is not considered. |
| 4 | WALLS:(Internal & External)LGSF works: 150 GSM 550 MPA Zincalume sections – C75-100 mm sections 0.75/1.0 mm BM thickness, designed using Framecad/Supracad.The steel manufacturer shall provide an Environmental Product Declaration (EPD) to the MES, ensuring transparency in the material's environmental impact. The coated steel finish shall be free from defects and shall provide branding on back side with product details such as thickness, grade,coating mass, date, mfg. name and MES. The steel manufacturers test certificate for the chemical and mechanical properties of steel must be approved by the concerned engineer authorised by Engineer-in-charge prior to installation. The manufacturer of the steel and profile should be the same.Designed in IBC code but referring to IS codes and values |
| 5 | Decking:Supply & Installation of Structural Decking 51 DECK Profile in Galvanized Steel shall be minimum 0.8mm thick BMT 550MPa yield strength as per IS 513 with a crest height of 51 mm at a pitch distance of 316mm c/c having a cover width of 960 mm, 3mm deep and 19 mm long embossment on either side of webs which are diagonally opposite to each other to provide the mechanical interlocking between the steel and concrete ensuring adequate composite action between steel and concrete.The panel shall have v”shape of 10mm deep on rib and panasa stiffener and male and female interlocking at side lap. The deck panel shall be coated with hot dipped zinc with coating mass of Z 275gm per sqm on both sides as per IS277 or approved equivalent as per direction of Engineer in charge.The Steel conforms to IS1397 and BSEN10147:2000. The profile comprises of intermediate male & female ribs for every interlocking of side lap joints.Decking sheet to be installed using Studwelding as approved by Engineer in charge |
| 6 | External Wall sheet:Supply & Installation of 0.53mm TPT pre-painted Zincalume Trapezoidal roof sheet of 935mm effective cover width with eleven major corrugation,24mm high rib spaced at 93.5mm c/c.The end rib shall have anti-capillary groove and return leg. The steel sheet shall be fastened with 40μm zinc coated or 25μm zinc-tin alloy coated, Hex head, self drilling screw as per AS 3566-2002 Class 3 fasteners of tata or approved make.Coil Specifications-The base steel of sheet material shall be nominal 0.45mm Base Metal Thickness (BMT) substrate and 0.53mm Total Painted Thickness(TPT) ,coated with hot dipped Zincalume alloy coating (i.e. 55%Al,43.4%Zinc,1.6%Si) AZ 200 (i.e.minimum of 200g per SqmAl-Zn alloy coating mass total on both sides) having yield strength of 550MPa conforms to IS15961 and factory painted and oven baked with total 35 micron paint DFT conforms to IS15965- class 3. On exposed surface of the sheet shall be having 20-micron DFT of Super Durable Polyester exterior quality paint system (IS15965- class 3) - (Free from Lead and heavy metals), over 5-micron DFT corrosion inhibitive polyester primer and on reverse side of sheet shall have 5-micron DFT polyester coat over 5-micron corrosion inhibitive polyester primer.The paint system shall have inorganic and ceramic pigments in Super Durable Polyester resin. |
| 7 | Internal Wall sheet & Ceiling sheet:Supply & Installation of 0.53mm TPT pre-painted Zincalume profile sheet of 1110 mm effective cover width profile with nominal 3.5mm deep ribs at pitch of 48mm centre to centre distance.The steel sheet shall be fastened with 40μm zinc coated or 25μm zinc-tin alloy coated ,Hexhead ,self-drilling screwasper AS 3566-2002 Class 3 fasteners of tata or approved make.Coil Specifications-The base steel of sheet material shall be nominal 0.45mm Base Metal Thickness (BMT) substrate and 0.53mm Total Painted Thickness (TPT), coated with hot dipped Zincalume alloy coating (i.e. 55%Al,43.4%Zinc,1.6%Si) AZ200 (i.e.minimum of 200g per Sqm Al-Zn alloy coating mass total on both sides) having yield strength of 550MPa conforms to IS15961 and factory painted and oven baked with total 35 micron paint DFT conforms to IS15965- class 3. On exposed surface of the sheet shall be having 20-micron DFT of Super Durable Polyester exterior quality paint system (IS15965- class 3) - (Free from Lead and heavy metals), over 5-micron DFT corrosion inhibitive polyester primer and on reverse side of sheet shall have 5-micron DFT polyester coat over 5-micron corrosion inhibitive polyester primer. |
| 8 | Providing and fixing of external thermal insulation and composite system with first layer of self-extinguishing type expanded polystyrene (EPS insulation boards of 50mm thick (max 1mX0.5m section), conforming to IS 4671:1984, having thermal conductivity of 0.034 W/ mK, (measured as per IS 3346-1980), density of 20-24kg/m3 measured as per IS 5688-1982, fire retardant property self-extinguishing type as per EN 13501-1, bonded with special polymer modified cementations adhesive conforming to EOTA ETAG 004 (European Technical Approval) formulated to bond polystyrene insulation boards to typical mineral substrate (according to ETAG 004) and Polypropylene mechanical fasteners with plastic pin confirming to EOTA ETAG 014 (European Technical Approval) having dia 10mm & L=200mm on finished level wall and the junction between two adjacent EPS boards to be sealed with low expansion moisture cure Polyurethane Foam. Second layer consists of Fiberglass mesh covered with alkali-resistant coating, mass per unit area>145 gm/m2, mesh size: 3.9X4.0mm +- 10% embedded in special polymer modified cementations Base Coat with hydrophobes and the corners will be protected with Corner-beads with alkali-resistant mesh wings at least 10 cm wide, mesh mass per unit area min 145 gm/m2. The surface will be leveled, finished, made smooth complete in all respect as per directions of Engineer-in-Charge. |
| 9 | Wall Insulation: Providing & Fixing 48 KG/m3 Rock wool insulation with aluminum foil laid over the top of purlins, complete as per directions of Engineering -in- charge. ndow: 2 track UPVC window with fixed mosquito net installed out side the window along with MS Grill on external surface. Door: 35 mm Flush door for rooms and UPVC Door for toilets. Flooring : Vitrified tiles 2x2 - Kajaria or Eq.Board on internal room:12.5 mm Gypsum board laid on top of 8 mm cement fiber board with proper jointing and tapping and paint as per engineer in charge. Civil Works: Civil foundation– Footing as per site requirement –with tie beam and plinth protection wall in Brick. Footing size – Typical (3.5m x 3.5m) depth 1500 mmSlab–100mm from top of deck sheet with double reinforcementSoil compaction using available soil to raise the overall land by 450 mm (150 mm to be GSB/Sub grade material and 75 mm to be PCC (as approved by GE) with reinforcement fiber added for strength. AAC block work where ever necessary–(Wet area) Electrical works: Basic electrical conduit and wiring with fixtures-internal. plumbing : Toilet and kitchen area as per layout submitted. Special services : Fire fighting system along with conduit for CCTV, S&T , Solar considered. |
| 10 | NOTE: Schedule ‘A’ Part II to XIII under Ser No 2.01 to 2.12 are Prepriced by MES. |
| 11 | Lump sum price worked out by the Contractor for “ SITE CLEARANCE, EXCAVATION AND EARTH WORK ” as listed in Schedule ‘A’ Part II |
| 12 | Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION) ” as listed in Schedule ‘A’ Part III |
| 13 | Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY WORKS\\" as listed in Schedule ‘A’ Part IV |
| 14 | Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY WORKS\\" as listed in Schedule ‘A’ Part V |
| 15 | Lump sum price worked out by the Contractor for \\"EXTERNAL ELECTRIC SUPPLY WORKS” as listed in Schedule ‘A’ Part- VI |
| 16 | Lump sum price worked out by the Contractor for “ROAD , PATH AND CULVERT ” as listed in Schedule ‘A’ Part- VII |
| 17 | Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL WORKS” as listed in Schedule ‘A’ Part -VIII |
| 18 | Lump sum price worked out by the Contractor for \\"AREA DRAINAGE WORKS” as listed in Schedule ‘A’ Part IX |
| 19 | Lump sum price worked out by the Contractor for “COMPOUND WALL/GATE\\" as listed in Schedule ‘A’ Part X |
| 20 | Lump sum price worked out by the Contractor for “RAIN WATER HARVESTING\\" as listed in Schedule ‘A’ Part XI |
| 21 | Lump sum price worked out by the Contractor for “AIR CONDITIONING\\" as listed in Schedule ‘A’ Part XII |
| 22 | Lump sum price worked out by the Contractor for “CENTRAL AIR COOLING SYSTEM\\" as listed in Schedule ‘A’ Part XIII |
| 23 | Lump sum price worked out by the Contractor for “DEMOLITION AND DISMANTLING WORKS\\" as listed in Schedule ‘A’ Part XIV |
| 24 | SCHEDULE `A' PART - XVI MISC ITEMS (B/R & E/M, srl Item No.3.01 to 3.31) is not prepriced by MES and prepriced rates indicate 0.00 under column 5 signifies this fact only. |
| 25 | EXTERNAL WATER SUPPLY |
| 26 | Supply and laying Galvanised Iron (GI) pipe, \\" medium grade\\" including fitting of size 63 mm dia complete all specified and directed. |
| 27 | M&L for construction of valve chamber of size 900x900x1200mm internal size suitable for valves with PCC 1:4:8 type D 2 for foundation and brick masonry wall in cement mortar 1:6 PCC 1:3:6 type C 1 for coping rendering in CM 1:4,15mm thick including Provn of mild steel sheet cover 3.0mm thick on 40x40xx6mm angle iron frame work with two coats of synthetic enamel black paint over a coat of red oxide primer and locking arrangement including necessary excavation earth work all as specified and directed. |
| 28 | EXTERNAL ELECTRIC SUPPLY |
| 29 | Boring of holes under road ,Pavement ,hard standing trench less technolgy using ultra sound technique and necessary machine incl HDPE pipe of 150mm dia suitable for 0.4mpa working pressure complete all specified and directed. |
| 30 | S&F cable joining kit for 1.1 KV grade cable for indoor termination, heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE, armoured Al conductor cable of size 400 sqmm complete all specified and directed. |
| 31 | Supply and Fixing LED Building security light fitting 25 watt including bracket, clamps and twin core wire for connection complete all as specified and directed. |
| 32 | Supply , install , test & commissioning of CPRI approved LT Panel of size 2000 mmx 1800mmx 900mm, indoor, Cubicle type, factory fabricated out of CRCA Sheet of 3.15 mm thick dust, vermin proof, weather proof, IP-54 Grade of protection, fabricated on 50x50x5 mm thick MS angle iron frame both side opening and locking arrangement including providing Aluminium bus bar of capacity 800 Amps rating for 415 V 50 Hz 3 Phase system including interconnection with multistranded conductor/Strips/Wires/Cables with hot shrink color coded sleeves with RYB colours and suitable adopter boxes with spreader links for connecting cables with switch terminals ,cable gland for each cable (Where necessary) complete all as specified and directed with following:-. ( Main LT Panel)INCOMING:-(a) MCCB 500 Amps 4 pole 50 K A(b) Voltmeter 0-500 volt(c) Amperemeter 0-600 Amp(d) Phase Indicating LED Lamp (03 Nos R Y B)(e) Bus Bar copper 800 A ratingOUT GOING:-(a) MCCB 200 Amps 4 pole 25 KA-01(b) MCCB 160 Amps 4 pole 25 KA-03 (c) MCCB 100 Amps 4 pole 25 KA-01 |
| 33 | INTERNAL ELECTRIC SUPPLY |
| 34 | Supply and fixing of Modular metal flush box 8 module complete all as specified and directed. |
| 35 | Supply and fixing of Modular metal flush box 12 module complete all as specified and directed. |
| 36 | Supply and fixing of modular cover plate white with frame complete for 12 module complete all as specified and directed. |
| 37 | Supply and fixing energy saving decorative box type batten light fitting 230 Volts surface mounted complete with high efficiency PMMA diffuser soft glare free light LED Tube light 10 watt ,blue coloured and caps with all accessories pre-wired,including providing flexible copper wire ,three core cable PVC insulated sheathed complete all as specified and directed by Engineer-in Charge |
| 38 | S & F telephone jack complete all as specified and directed. |
| 39 | S & F TV jack complete all as specified and directed. |
| 40 | M & L for VTPN 8 way sheet steel enclosure distribution boards, double door factory made 3 phase 415 volts, 100 A MCCB as incomer and 24 single phase outgoing copper bus bar of suitable size and PVC insulated to the out going circuits,complete all as specified and directed |
| 41 | Supply and fixing energy saving deep recessed down light fitting 230 Volts surface mounted complete with high efficiency soft glare free light LED round ceiling light having color temperature of 2700 to 3000 K (warm color) light 15 watt , with all accessories pre-wired,including providing flexible copper wire ,three core cable PVC insulated sheathed complete all as specified and directed by Engineer-in Charge |
| 42 | RAIN WATER HARVESTING |
| 43 | M&L for drilling 250 mm dia bore holes by DHT cum rotary method at any depth as in any type of soil maximum upto 200 mtr depth from natural ground level and including removal of surplus soil to a distance n exc 50M complete all as specified and directed. ( trial bore of 200mm dia upto 200mtr depth below ground level if any kind of soil strata incl hard stone /bolder incl elec loging ,ms cap ,ms plate iron clamp reducing socket etc.) |
| 44 | M & L for PVC pipe 200mm dia of pressure rating 6 Kgf/Sqcm laid in recharge pit all as specified and directed . |
| 45 | M & L for PVC perforated pipe 200mm dia of pressure rating 6 Kgf/Sqcm laid in recharge pit all as specified and directed . |
| 46 | GREASE TRAP |
| 47 | Removal & refixing of German Technology grease trap & restoring connections and other unforeseen items like shifting of cable, water supply line, sewage and other items complete all as specified and directed. |
| 48 | AIRCONDITIONING & REFRIGERATION |
| 49 | Supply and fix air cooled cassette type air conditioner, inverter based, electric driven, single phase units 220V - 240V, 50 Hz of capacity 3.5 TR, BEE 5 star rated complete all as specified and directed. |
| 50 | Supply and fix refrigerator, electric driven ( Single phase), capacity More than 195 Ltr and upto 310 Ltr, single phase units 220V - 240V, 50 Hz, BEE 5 star rated complete all as specified and directed. |
| 51 | CENTRAL AIR COOLING SYSTEM |
| 52 | Supply , install , testing & commissioning of CPRI approved LT Panel of size 1000 mmx 900mmx 900mm, outdoor, Cubicle type, factory fabricated out of CRCA Sheet of 3.15 mm thick dust, vermin proof, weather proof, IP-54 Grade of protection, fabricated on 50x50x5 mm thick MS angle iron frame both side opening and locking arrangement including providing Aluminium bus bar of capacity 250 Amps rating for 415 V 50 Hz 3 Phase system including interconnection with multistranded conductor/Strips/Wires/Cables with hot shrink color coded sleeves with RYB colours and suitable adopter boxes with spreader links for connecting cables with switch terminals ,cable gland for each cable (Where necessary) complete all as specified and directed with following:-. ( Air Cooler Panel)INCOMING(a) MCCB 160 Amps 4 pole 16 KA (b) Voltmeter 0-500 volt(c) Amperemeter 0-400 Amp(d) Phase Indicating LED Lamp (03 Nos R Y B)(e) Bus Bar Aluminium 250 A ratingOUT GOING(a ) MCCB 20 Amps 4 pole 16 KA ( Second floor)-02 Nos(b ) MCCB 63 Amps 4 pole 16 KA (G/F & F/F)- 02 Nos |
| 53 | Supply, Installation, testing and commissioning of Centralize evaporative Air Cooling system (Central Air Cooler) for G+2 comprising of following:-Coolator @ 43 Plus -43000CMH/25000 CFM of static pressure 80 mmwg -01 NosFor Ground and First FloorCoolator @ 34 plus - 34000 CMH / 20000 CFM of static pressure 80 mmwg -01 NosFor Ground and First FloorCoolator @ 17 plus - 17000 CMH / 10000 CFM of static pressure 80 mmwg -02 NosFor Second FloorEletric controller Elect Controller with 2 meter wire for connection with starter, MCCB, Contactor,Start/ Stop button,Overload relay, Single phase preventer and short circuit protection etc for Coolator -43 plus,Coolator -34 plus,Coolator -17 plus,Rectangular ductingDucting of size 22 gauge & 24 gauge GI sheet including duct support with nut, gasket joint, angle mounted threaded rod support with anchor fastnerSupply Air GrillAluminium powder coated supply air grill with damperCanvas ConnectionSupply and installation of canvas connectionThermal insulationNitrile thermal insulation with 13 mm thick Aluminium foil |
| 54 | DEMOLITION AND DISMANTLING |
| 55 | Taking down flushing cisterns and flushing pipes of any description/capacity complete all as specified and directed. |
| 56 | Taking down wash basins vitreous china any size and type including brackets complete all as specified and directed. |
| 57 | Taking down old u/s Bib taps 15mm bore any type complete all as specified and directed. |
| 58 | Taking down old u/s stop /angle valve 15mm bore complete all as specified and directed. |
| 59 | Dismantling existing old unserviceable LT panel including all accessories complete all as specified and directed. |
| 60 | Taking down the old MCBs/MCCBs any type by necessary cutting, chasses including disconnection of incoming and out going cable etc complete all as specified and directed. |
| 61 | Disconnecting and taking down unserviceable cable of size 50/95/120 Sqmm from pole/main switch board complete including necessary excavation complete all as specified and directed. |
| 62 | Taking out carefully earthing set complete of any type including earthing wire/strip complete all as specified and directed. |
| 63 | Taking down the TPN DBs any type by necessary cutting, chasses including disconnection of incoming and out going cable etc ccomplete all as specified and directed. |
| 64 | Taking down the SPN DBs by necessary cutting, chasses including disconnection of incoming and out going cable etc complete all as specified and directed. |
| 65 | Dismantling Tube Light fitting single / double rod/ Ceiling light fitting any type and wattage or CFL fitting of any type and bulk head fitting of any type or wattage, decorative light fitting complete all as specified and directed. |
| 66 | Disconnecting and taking down unserviceable cable of size 10 Sqmm/ 16 Sqmm/ 25 Sqmm from pole/main switch board complete all as specified and directed. |
| 67 | Taking down the Metal clad plug any type by necessary cutting, chasses including disconnection of incoming and out going cable etc complete all as specified and directed. |
| 68 | Taking down including disconnecting the electric connection of ceiling / exhaust/ ventilation fan dismantling blades, cleaning and depositing to store MES store yard complete all as specified and directed. |
| 69 | Taking down including disconnecting the electric connection of Geysers and depositing to store MES store yard complete all as specified and directed. Please Enable Macros to View BoQ information |