| 1 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and as directed. |
| 2 | Excavating in post holes (or similar holes) in soft\loose soil each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, |
| 3 | M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate as in foundation, filling, and mass concrete. |
| 4 | S&F mild steel work in tubular trusses/structures of square/round/ rectangular pipes, rafters, purlins including special shaped washer etc. complete using ERW or induction butt welded tubes confirming to IS-1161-1998 grade St-240 including notching, drilling, fitting, rivetting and or welding or connecting bolts and nuts, cleats, gusset plates etc complete all as specified and as directed. |
| 5 | S&F mild steel for wind ties for roof including securing bolts ,incuding cutting tops to shape as directed , drilling holes and similar works conforming to Fe-290 Gde E-165 |
| 6 | S & F for MS Framed work by fabrication such as grills, gratings, etc, with ends of bars shouldered and/or riveted, or forged into spike, framed guard bars, barred iron doors, ladders, framed balusters, walk ways railing framed of water tanks etc including portions framed and hung as gates including pintle hinges, stops, hand-made sliding bolts etc conforming to Fe-290, Gde- E-165, complete all as specified and directed. |
| 7 | S & F for MS purpose made butt hinges conforming to Fe-290, Gde-E-165 suitable for fixing to stone/concrete, door and window frames including fabrication work etc complete all as specified. |
| 8 | M & L for preparation of new or previously un treated steel and iron surfaces over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer or zinc chrome on steel and iron surfaces all as specified and directed. |
| 9 | M & L for preparation of new or previously un treated steel and iron surfaces n.exc 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer or zinc chrome on steel and iron surfaces all as specified and directed. |
| 10 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings |
| 11 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified. |
| 12 | S & F coloured galvalume ridges,corner piece,barge board,window flashing etc, 0.50 mm thick, fixed with L or J type,special screw or cranked hook bolts in roofs , walls etc. |
| 13 | Demolition of cement concrete any description any thickness and any position complete all as specified and directed. |
| 14 | M&L for 75mm thick cement concrete type C2 1:3:6 using 40mm graded aggregate as in plinth protection finished even and smooth without using extra cement, laid in bays, joints filled with sand and bitumen mixture at 1:1 ratio complete all as directed |
| 15 | M&L for 75 mm thick cement concrete type D-2 (1:4:8) using 40 mm graded stone aggregate as in sub base . |
| 16 | M&L100 mm thick for PCC 1:2:4 type B1 (using 20mm graded aggregate) as in path/ hard standing finishing smooth without using extra cement complete all as specified. |
| 17 | M&L100 mm thick for PCC 1:4:8 type D2 (using 40mm graded aggregate) as in path/ hard standing complete all as specified. |
| 18 | M&L for Forming contraction (Dummy) joints 65mm X 10mm wide, filled with sealing compound Gde 'B' for key scrubbing down with water etc. |
| 19 | Taking down existing water proofing tretment on RCC Non-accessible slab / beams with bitumen felt without damaging structure and removing the debris outside the MD land and M&L for plaster 15 mm thick on concrete surfaces in cement mortar 1:4 finished even and smooth using WPC @ 3% by weight of cement and preparing the surfaces to receive WPT treatment , applying a coat of bitumen primer confirming to IS - 3384-1986 @ 3% per sqm ,providing APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by torch application over primed surfaces all as specified and directed by Engr-In- Charge |
| 20 | M&L for Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises |
| 21 | M&L for Providing, cement concrete Type B0 1:2:4( 12.5mm graded aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges |
| 22 | M&L 60 mm thick (M-25 mix) glossy rubber mould interlocking tiles with grey cement and pigment conforming to IS-15658-2006 laid dry over 30 mm compacted sand bed, size & pattern of tiles all as directed by Engineer-in-Charge.NOTE: Sand to be measured & paid separately |
| 23 | M &LSand filling under floors or in foundations including wateringand consolidation |
| 24 | Dismantling wall and ceiling boards, any thickness including cover fillets, grid work of any description |
| 25 | M&L for providing 12mm thick Gyp boards in ceilings fixed to ceiling sections with screws @ 300mm centre to centre and making good joints Gypsum binder including preparing the surfaces of ceiling boards and applying 2 coats of acrylic oil emulsion distemper with GI frame work for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre, intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from sofits at approxly 900mm centre to centre with GI cleats, GI suspenders and steel expansion fasteners with and including ceiling section of 0.55mm thick having kurled web of 50 mm and flange of 26 mm each side with lips of 10.5mm fixed to the intermediate channel at 457mm centre to centre all as specified as directed. |
| 26 | M&L for false ceiling corners with designed angular shape of size 100x100mm with POP fixed on 6mm thick fibre board with 20x20mm, 0.55mm thick galvanised sections fixed at intervals not more than 750mm complete al as specified and directed by Engr-in-Charge. |
| 27 | S&F in repairs for false ceiling of perforated particle board/tiles 60X60 cm in size and 12mm thick fixed with nails to timber frame work or with staples on anodised aluminum snap grid fixed with screws all as specified and directed. |
| 28 | S&F in repair anodised aluminium snap grid frame work for false ceiling all as specified and directed. |
| 29 | Hacking out old broken glass (any thickness, size, quality or description) from wooden /steel frames or stone , concrete or brick surrounds, glazed with putty or fixed with beads. |
| 30 | S&F 4.00 mm thick sheet figured glass pin headed type and glazing with oil putty in square n exc 0.50 Sqm in each pane. |
| 31 | Taking down cement plaster on brick or stone walls etc including raking out joints hacking for key scrubbing down with water etc. |
| 32 | Material & labour for rendering 15mm thick in cement sand mortar 1:4 on fair faces of brick work, PCC block masonry or concrete surfaces, mixed with water proofing compound and finished even and smooth without using extra cement as per manufacturer's instructions complete all as specified and as directed by the Engr-in-Charge. Note:- (a) Supply only Integral water proofing compound will be measured and paid seperately (b) Height of building may vary from 3 m to 6 m. |
| 33 | Supply only integral water proofing compound |
| 34 | M&L for 10 mm thick rendering for fair faces of concrete surfaces on walls in CM 1:6 and finished even and smooth without using extra cement as specified. |
| 35 | M&L for 5 mm thick rendering for fair faces of concrete surfaces on ceiling in CM 1:3 for fair finished surfaces. |
| 36 | M&L for preparing new plastered wall surfaces and applying two coats of distemper with distemper oil emulsion, white or tinted including one coat of Birla White Putty by finishing the surfaces even and smooth complete all as specified and directed by EIC. |
| 37 | M&L for preparing new plastered ceiling/soffits of chajjas surfaces and applying three coats of white wash complete all as specified and directed by Engineer-in-Charge. |
| 38 | M&L for preparation of new or previously untreated plastered external surfaces and applying two coats of exterior emulsion paint (in camouflage pattern as approved by the GE) over a coat of primer all as specified and directed by Engr-in-Charge. |
| 39 | S&F in Repairs Bird proofing netting in Hangers, storage accn etc Complete all as specified Bird proofing net of Co-Polymer Nylon monofilament, ultraviolet stabilized with aperture of 25mm x 25mm Machine Knotting with the dia of filament wire as 0.80mm, melting point 260 deg, tensile force to resist 23.08 Kgs as approved by GE.(Note:- Height of Bldgs approx 12mtr considered) |
| 40 | Repairing/ Taking down Aluminium window/doors of any description area exc 1.00Sqm n. Exc 2.00 Sqm repairing/ retightening screws, aluminium clips and securing top & bottom rails using MS 10mm bar having both sides threading incl bolting, fixing of new rubber padding, Aluminium snap bidding, glazing clips and re-fixing resuring in same opening completed all specified and as directed by Engineer-in-Charge |
| 41 | All as item No 40 above here in before but area n.exc 1.00 Sqm. |
| 42 | Taking down Chowkaht or frame (without taking off shutter from frame) exc. 1.50 Sqm but n.exc. 4.00 Sqm. |
| 43 | Taking down Chowkaht or frame (without taking off shutter from frame) n.exc. 1.50 Sqm. |
| 44 | S&F Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified |
| 45 | S&F Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified |
| 46 | S & F tinted sheet glass 5mm thick, selected quality and glazing with rubber beading in squares |
| 47 | Supply & Fix aluminium anodised grill of approved shape with opening in grill 66mm x 80mm (diagonally) or nearest to + 5mm made out of standard aluminium moulded section of size 6mm x 7mm |
| 48 | S&F in repairs Steel rolling shutters 1 mm thick, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: but gear operated type with bevel gear box and crank handle |
| 49 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning repairing, etc. measured separately) |
| 50 | Exc 250 litres & n exc 500 litres |
| 51 | Exc 500 litres & n exc 1000 litres |
| 52 | Taking up or down following size of steel tubing and connections including removal to store for reuse or credit to contractor Note : (a) The rates apply to pipes above or below ground only in repairs and alterations. (b) 'The rates for taking down piping, etc., and removing to store include disconnection of fittings from tubing,where required. |
| 53 | 15mm bore of pipe |
| 54 | 20mm bore of pipe |
| 55 | S&F CPVC pipes ISI marked with all fittings fixed with solvent cement complete to walls and ceilings or laid in floors of following sizes: (SDR-13.5 of plain CPVC) |
| 56 | 25mm nominal dia of pipes |
| 57 | 32mm nominal dia of pipes |
| 58 | S&F in repairs 25mm bore ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 455 gms) Complete all as specified. |
| 59 | M&L for Non skid coloured ceramic tiles 7 to 8mm thick area of each tile exc 0.06sqm but n exc 0.11sqm in floors etc set and jointed in neat cement slurry and pointed in white cement to match, over and including 15mm thick screed bed in CM (1:4) laid over and including 25mm thick PCC (1:2;4) type B-1 using 20mm graded crushed stone aggregate,complete all as specified and directed |
| 60 | M&L for Glazed Ceramic coloured Tiles, 350X250X7mm/450X350X7mm thick in size, set on Vertical Surfaces such as Skirting, Dado, etc,over and including 10mm thick rendering in cement mortar 1:3 Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the shade of the Tiles, complete all as specified and as directed. |
| 61 | M&L for Vitrified Ceramic tiles light shade 9-10 mm thick Colour (square/rectangular) polished, area of each tiles exc .18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, including Screed Bed 15 mm thick in Cement Mortar (1:6) complete all as specified and as directed. |
| 62 | all as per above item No. 55 but in CM(1:3) 10mm thick rendering on vertical surfaces all as per specified and directed. |
| 63 | Demolition of PCC block masonry built in cement mortar all as specified |
| 64 | M&L for providing precast cement concrete block masonry type C1 1:3:6 using 20mm graded aggregate with solid blocks, exc 10cm in width and setting in CM 1:6 complete Please Enable Macros to View BoQ information |