| 1 | Dismantling plain or corrugated steel sheets any gauge thickness including Nanital or similar pattern roof covering including ridges complete all as specified and directed. |
| 2 | S&F Prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified, all as specified and directed. |
| 3 | S&F Prepainted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge, hips, valley/ eaves/ rain water gutters, drip and straight flashing (length and girth as fixed), fixed with self tapping screws all as specified |
| 4 | M&L for Demolition of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed. |
| 5 | S&F Aluminium anodised snap grid frame work of size of size 605 mm X 605 mm as in false ceiling, flat or sloping (pattern as per manufacturer's catalogue/ instructions), cutting holes for electrical fittings fixed on and including aluminium tee of size 25mmX25mmX1.50 mm as main runner, aluminium tee of size 25mmX25mmX1.25 mm as cross runner and aluminium angle of size 25mmX25mmX1.25mm at the perimeter suspended from soffit at approx 900 mm centre to centre with hangers 6 mm dia galvanised (length as per site requirement) adjusting level fixed to roof by means of ceiling cleats made out of galvanised iron flat 40 mm X 3 mm size, 60 mm long and expansion hold fasteners 12.5 mm dia, 40 mm long including perforated particle board/tile 12mm thick for insulation and acoustic purpose as in ceiling flat or sloping 60cmx60cm in size including necessary scaffolding all as specified and directed. |
| 6 | M&L for Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15 cm thick above or below ground level complete and disposal of unserviceable material, debris and rubbish to a distance not exceeding 100m complete all as specified and directed. |
| 7 | M&L for 75mm thick PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregates) as in floor finish, surface finished even and fair without using extra cement complete all as specified and directed. |
| 8 | M&L for 40 mm thick PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregates) as in levelling course, surface finished even and rough to receive top finish complete all as specified and directed. |
| 9 | Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubish off the complete all as specified and directed. |
| 10 | M&L Non-Skid,Mat finish, premium quality, joint free (edge cut), coloured/ printed ceramic tiles 7-8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in floors etc. set and jointed in neat cement slurry and including 15mm thick bedding layer in cement mortar (1:4) including necessary cutting and waste as per site requirement pointed in white or coloured cement to match complete all as specified and directed. |
| 11 | M&L Glazed ceramic coloured tiles of size 450 mm x 350 mm x 7 mm/350 mm x 250 mm x 7 mm thick as in vertical surfaces such as skirting, dado, set and jointed in neat cement slurry coloured cement to match the shade of tile over and including 10 mm thick cement screed in cement mortar 1:3 complete all as specified and directed. |
| 12 | M&L for PCC 1:2:4, nominal mix, type B-1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping, bed plates and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified. |
| 13 | M&L for Taking down cement plaster including backing etc from brick/stone walls / concrete surfaces including raking out joints, hacking for key , scrubbing down with water etc complete all as specified and directed |
| 14 | M&L for Rendering cement plaster 15mm thick in cement mortar 1:6 on fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified. |
| 15 | M&L Rendering cement plaster 15mm thick in cement mortar 1:4 on fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified. |
| 16 | Supply only intergal water proofing compound, complete all as specified. |
| 17 | M&L for Preparation of new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over a coat of chalk whiting complete all as specified. |
| 18 | M&L for Preperation of new plastered surfaces of walls and applying applying two coats of 100% acrylic smooth emulsion exterior grade with silicon additives and anti-algal properties Exterior over one coat of water proof primer (Dam prime suprema) on walls and chajjas with 10% dilution of water including smoothing the surface with wall putty @ 2kg/ Sqm of average thickness 2mm with silicon additives and sanding these surface for removal of loose particles , complete all as specified. |
| 19 | S&F in repair Harrison rail (Curtain rail), mild steel, chromium plated with and including fixing brackets, stops, rollers etc. complete all as specified |
| 20 | Vitreous China wash down water closet (pedestal pattern), white including traps, connection to drain or outgoing pipe, flushing pipe, anti-syphonage pipe complete including fittings, PVC white seat cover and chromium plated jet including PVC connection, fixed complete including demolition of old unservicable WC and provision of plain cement concrete M-15, type B-I, using 20mm graded crushed stone aggregate, fixed in repairs all as specified. |
| 21 | Vitreous Chinaware squatting pan, ‘Orrisa pattern’ size 580 mm x 440 mm, crystal white, with cast iron ‘P’ or ‘S’ trap, front or back inlet, integral foot rest with provision of plain cement concrete 1:2:4, type B-I using 20 mm graded crushed stone aggregate complete all as specified, incl making connections to trap and to flush pipe etc,fixed in repair, all as specified. |
| 22 | Toilet paper holder of vitreous china fixed to walls with chromium plated (CP) brass screws. |
| 23 | S&F in repair PVC valve less, snow white, syphonic action type flushing cistern 10 litre capacity, superior quality, plunger type, low level, with inlet, ball valve, float and handle, 32 mm dia PVC long bend flush pipe 90cm long and 15 mm dia 450 mm long PVC connection with CP brass coupling nuts and PVC washers at both ends all as specified. |
| 24 | Wash basins, Vitreous China (Flat white type) size 550mmx400mm, crystal white with and including cutting for and pinning on ends of brackets, 450 mm long PVC connections 15mm size with PTMT coupling nuts at both ends, trap, grating and Union for discharge pipe, waste, chain and plug and porcelain stopper, waste pipe of polythylene of low or high density or PVC of 32mm dia including , 32mm dia waste fittings, brass chromium plated with long screwed shanks and fly nuts, flange and bedded in red lead cement and other end fixed, screwed for iron pipe and fixed, complete all as specified. Make: Cat Part No. 1008 of Cera or equivalent in makes mentioned in Appx |
| 25 | S&F in repairs Brass CP wall mixer for mixing hot & cold water screwed down for iron pipe and fixed 15 mm bore, complete all as specified and directed. |
| 26 | S&F in repairs Stop valve/Angle Valve cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions for 15mm bore iron pipe or for unions complete, all as specified. |
| 27 | S&F in repair Bib tap, cast copper alloy ,chromium plated, fancy type , screwed for iron pipe or for brass ferrule of 15 mm bore complete all as specified and directed. |
| 28 | S&F in repairs Brass chromium plated tubular towel rail 20 mm dia, \\"D\\" type, 60 cms long between flanges with and including chromium plated brass brackets, brass screws complete all as specified. |
| 29 | S&F in repair 600x450 mm bevelled edge mirror 5 mm thick of slected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plug with chromium plated brass screwed and cup washers. |
| 30 | S&F in repair PVC connections 15 mm size with PTMT nuts of length 450mm complete all as specified and directed. |
| 31 | S&F in repair Brass chromium plated shower rose 125mm size with or without swivel joints, including fixing to steel pipe or union complete all as specified. |
| 32 | S&F G I tubing medium grade of 15 mm bore with all fittings and fixtures fixed to wall and ceiling or laid in floor/trenches, including taking down old GI tubing complete all as specified and directed. |
| 33 | S&F G I tubing medium grade of 20 mm bore with all fittings and fixtures fixed to wall and ceiling or laid in floor/trenches, including taking down old GI tubing complete all as specified and directed. |
| 34 | S&F Rotational moulded high Density polyethylene water storage tank 500 Ltrs and coforming to IS, hoisted and fixed in position including dismantling of old water tanks capacity exc 250 ltrs but n.exc 500 ltrs in any position and removing from the site or to store complete all as specified. |
| 35 | S&F in repair Ball brass valves, 20mm bore high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed, complete all as specified. |
| 36 | S&F in repair Stop valves cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions for 20mm bore iron pipe complete, all as specified. |
| 37 | S&F Sheet glass, 3mm thick ordinary quality and glazing with oil putty in squares n.exc 0.5 sqm each pane complete all as specified and directed. |
| 38 | M&L for Taking down and removing chowkats with shutters (without taking off shutters from chowkat) not exceeding 1.50 Sqm each complete all as specified and directed. |
| 39 | M&L for Taking down and removing chowkats with shutters (without taking off shutters from chowkat) exc 1.50 Sqm but not exc 4.00 Sqm each complete all as specified and directed. |
| 40 | S&F 2nd class hardwood (Sal) plain solid straight chowkats and frames wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and directed. |
| 41 | 35 mm thick 2nd class hard wood (Sal/Hollock) glazed & skeleton factory made shutters, open rebated and prepared to receive glass, gauze etc (without sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass, etc, sizes of members of door shutters as specified in SSR- 2009 Part-I Section 8.24(a) complete all as specified and directed. |
| 42 | 35mm thick second class hardwood (Sal/Hollock) factory made plain framed panelled shutter (two panel) with lock rails & panel of 9 mm B.W.P commercial ply wood or 12 mm thick veneered particle board with commercial veneering on both side. The size of rail and stile as per IS:1003 (Part-I) kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 43 | S&F Solid PVC Door Frame of size 50mm x 47 mm made out of 5mm single side prelam PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing as shown on page No 176 to 183 of MES SSR 2020 Part-II compete all as specified and directed. (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life) |
| 44 | S&F Factory Made Solid PVC Moulded Door Shutter, with wood free EPS particle board core,28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawinge,as shown on page No 176 to 183 of MES SSR 2020 Part-II compete all as specified and directed. |
| 45 | S&F Aluminium anodized barrel tower bolt of extruded section of size 200 mm and fixed complete all as specified and directed. |
| 46 | S&F Aluminium handles, cast type, anodised of size 150 mm complete all as specified and directed. |
| 47 | S&F 250mm long aluminium alloy, anodized, sliding door bolt with hasp, staple(bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed. |
| 48 | M&L for Preparation of new wooden surfaces of any description, not otherwise described, over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 49 | Demolition and breaking up 75mm/110 bore drain pipe (Salt glazed ware, AC or Reinforced concrete, PVC) set in cement mortar complete all as specified and directed. |
| 50 | S&F of PVC (SWR) 110mm bore (dia) soil, waste and ventilating pipe, singe socketed, in any length with Rubber Ring laid in trenches or in floors, fittings, etc, complete all as directed and all as specified. |
| 51 | S&F of PVC (SWR) 75mm bore (dia) soil, waste and ventilating pipe, singe socketed, in any length with Rubber Ring laid in trenches or in floors, fittings, etc, complete all as directed and all as specified. |
| 52 | S&F 110 mm dia PVC(SWR) bend, any radius complete all as specified and directed. |
| 53 | S&F 75 mm dia PVC(SWR) bend, any radius complete all as specified and directed. |
| 54 | S&F PVC (SWR) floor trap, plain with grating including jointing with solvent cement for 75mm bore pipe, complete all as specified. |
| 55 | Taking down point wiring with aluminium/ copper conductor for light point, socket point/ power point etc. in PVC casing and caping, surface pvc/ steel conduits, wood batten with clips including taking down board any type and size complete with any type of switches, sockets, holders, (batten or pendent type), ceiling rose etc. The light fittings (any type), main switches, distribution board with MCB’s of any capacity and make are to be removed/ replaced if required and all as specified and directed. NOTE: - Existing fan regulator any type (Where required) and electric meters are to be refixed and connected properly where required. |
| 56 | Point wiring for one light/fan/call bell point controlled by one 5/6 Amp switch with 1.5 Sqmm two single core multistranded copper conductor FRLSH, PVC insulated (unsheathed) heavy duty cable 1100 volts including continuous earth wire of size 1.5 Sqmm copper conductor multistrand FRLSH, PVC insulated (unsheathed) drawn into concealed rigid non-metallic PVC conduit Med Grade ISI marked not less than 20mm wide of 1.8mm wall thickness ISI marked including modular GI sunken flush box (Pressed steel powder coated Modular GI sunken flush boxes and cover plates of any way i.e. 1 to 8 way as per site requirement suitable for modular switch/socket) for mounting switches, sockets, fan regulators etc & making good to disturbed surfaces as well as matching with existing whitewash colour/surface complete all as specified and as directed for the following:- (a) Wiring shall be done by using proper colour coding(b) Earth wire shall be of green colour(c) On RCC roof/ceiling PVC conduit shall be provided on surface with proper fixing clamps all as directed. |
| 57 | All as per serial item No '56' above, but for one 3 pin 5 Amps socket outlet on the same board all as specified and directed. |
| 58 | All as per serial item No '56' above, but for one 3 pin 5 Amps socket outlet, independent all as specified and directed. |
| 59 | All as per serial item No. '56' above but for 3 pin 15 Amps socket out let independent with 4 Sqmm PVC copper conductor cable and and PVC insulated, unsheathed 4 Sqmm stranded copper conductor cable as continuous earth wire, all as specified. |
| 60 | S&F Modular switch 1 way 6A, 1 module, complete all as specified. |
| 61 | S&F Modular switch 1 way 16A, 1 module, complete all as specified. |
| 62 | S&F Modular Socket, 5/6 A - 2/3 pin combined 2 module, complete all as specified. |
| 63 | S&F Modular Socket 6A/16A - 2/3 pin combined , 2 module, all as specified and directed. |
| 64 | S&F Modular Bell push 6A 1 module, complete all as specified. |
| 65 | S&F Bell, AC, 230 volts, single pole all as specified. |
| 66 | S&F Ceiling rose, 65 mm to 50 mm, two to three terminals, PVC/ Polycarbonate, insulated body fixed on PVC block, all as specified. |
| 67 | S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for angular/ batten fittings complete all as specified & directed. |
| 68 | S&F LED lights fitting 1x 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed |
| 69 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete, complete all as specified. |
| 70 | LED Luminaire 600mmx600mm, 36 watt, 6500K, Ultra modern recess mounting luminaire with high performance LEDs, suitable for mounting with Armstrong/Grid ceiling, complete all as specified |
| 71 | S&F 35Watt New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08. connecting with PVC insulated three core flexible copper conductor of suitable size from ceiling rose to fitting including bracket made up og 32mm dia GI pipe light grade 1.5 metre long and bent to shape required, complete all as specified |
| 72 | Supply and Fixing Replacement of Sheet metal enclosures for DBs when MCBs to be used, single pole and neutral, 8 way, double door, 240 volts with 200 Amp rated bus bar completed all as specified. |
| 73 | S&F MCB SPN 32 Amp, 240 Volts, B Curve , 10 KA all as specified. |
| 74 | S&F MCB SP 6 to 32 Amp, 240 Volts, B Curve , 10 KA all as specified. |
| 75 | Sub main wiring with two single core PVC insulated cable 1100 volts grade with copper stranded RLS conductor of size 2.5 Sqmm (2 single run) with one continuous FRLS copper earthing lead wire of size 2.5 Sqmm and drawn into PVC conduit/ casing & capping with all fittings/ accessories, junction boxes 1 to 4 way 20mm dia, cutting chases, making good in cement mortar (1:3), finishing surfaces to match with existing and connected to common earth dolly complete and as directed. Note :- Two run (each run of 1 RM) of 2.5 sqmm copper conductor and one RM of earth wire of 2.5 Sqmm, shall be measured as one RM). |
| 76 | Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron wire 4.0mm dia (as earth lead wire), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in PCC (1:2:4), type B-I using 20mm graded crushed stone aggregates with 40mm thick precast cover of size 550 mm X 550 mm X 75 mm of RCC (1:2:4), type B-I, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion. |
| 77 | Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron strip 25mm x 4mm (as earth lead strip), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in PCC M-15, type B-I using 20mm graded crushed stone aggregates with 40mm thick precast cover of size 550 mm X 550 mm X 75 mm of RCC M-15, type B-I, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion. |
| 78 | Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexognal head screw, fixed in replcement of complete all as specified and directed. |
| 79 | S&F Aluminium strip 25x3.15 mm thick fixed with procelain/PVC saddle and fixing serew etc with minimum twonumber saddles with screws on and including PVC gutties in each one mtr of length for roof conductor and down conductors above ground,fixed in replcement of complete all as specified and directed. |
| 80 | S&F in Replacement of Air termination single pointed aluminum rod 12mm dia and 300mm long and fixed including taking out old air termination rod complete all as specified. |
| 81 | S&F Single pole and neutral enclosure with a two pin and earth plug and socket , 240 Volts, complete with one single pole MCB 20 Amp double pole, complete all as specified. Please Enable Macros to View BoQ information |
| 82 | S&F Single pole and neutral enclosure with a two pin and earth plug and socket , 240 Volts, complete with one single pole MCB 20 Amp double pole, complete all as specified. Please Enable Macros to View BoQ information |