| 1 | M&L for 1st class Non skid vitrified ceramic coloured tiles Group B I (a) 7 to 8mm thick (Square or rectangular) area of each tile exceeding 0.11 but not exceeding 0.18 Sqm, laid in floors etc, set and jointed in tile adhesive with 3mm spacers and pointed in epoxy coating grout to match the shade of tiles with and including laying of 15 mm thick screed bed or bedding layer in CM 1:6 complete including dismantling of existing floor tiling including cement mortar bedding and removing rubbish off the premises complete all as directed. |
| 2 | M&L for 1st class full body Vitrified coloured tiles Group B I (a) 10mm thick (Square or rectangular) polished, area of each tile exceeding 0.42 but n exceeding 1.00 Sqm, in floors etc, set and jointed in tile adhesive with 3mm spacers and pointed in epoxy coating grout to match the shade of tiles laid over and including 15 mm thick screed bed or bedding layer in CM 1:4 including dismantling floor hearth or wall tiling including cement mortar bedding complete all as specified and directed. |
| 3 | M&L for Glazed vitrified (high gloss) coloured tiles (Premium quality) of size 600x300x7-8mm thick, as in vertical surfaces such as dado, skirting etc set and jointed in tile adhesive with 3mm spacers and pointed in epoxy coating grout as per manufacturers instructions including rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:6 for receiving wall tiles and dismantling of existing tile/stone complete all as directed. |
| 4 | S&F in repair single piece Vitreous china any shade cascade floor mounted single piece water closet P/S trap with dual flush for UF soft close slim seat cover, hinges fittings, conversion bend, fixing accesories complete all as specified and directed. Make : Jaquar Cat part No OPS-WHT15753NS250UFSMZ/ Cera cat part No S1013105/Kajaria cat part No KB-3007 |
| 5 | S&F Vitreous china full set pedestal type wash basin, white, flat back, size 585x450x220mm including bracket, CP brass 32m dia coupling, waste pipe fixed in repair complete all as directed. Make : Jaquar Cat part No Jaguar FLS-WHT-5801 & 5301/Cera cat part No S2040112 & S2090107 or equivalent. |
| 6 | S&F in repair PVC connection 15 mm size with brass nuts of length 450 mm complete all as specified and directed. |
| 7 | S&F in repair for bevelled edge looking mirror of of any size, selected quality glass with design as apporoved by GE, frame less and fixed to chromium plated brass screws and studs complete all as specified and directed. |
| 8 | S&F in repair sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long. |
| 9 | S&F in repair Corner glass shelf assembly with bracket complete all as specified and as directed. |
| 10 | S&F in repair toilet paper holder with flap guard fixed to walls with chromium plated brass screws. |
| 11 | S&F in repair soap dish holder fixed to walls with chromium plated brass screws. |
| 12 | S&F in repairs CP brass hot & cold single lever basin mixer with 450mm long braided hoses cast copper alloy with centre hole for WHB complete all as directed by Engineer-in-charge. Make : Jaquar Opal Prime Series/ Cera Ruby series/Somany Bellis series |
| 13 | S&F in repairs CP brass hot & cold 15mm dia wall mixture for mixing hot & cold water with shower provn with connecting legs & flangs in complete all as specified. Make : Jaquar Opal Prime Series/ Cera Ruby series/Somany Bellis series |
| 14 | S&F in repairs 15mm bore long body bib tap chromium plated fancy type with wall flange and aerator fixed in repair complete all as specified and directed. Make : Jaquar Opal Prime Series/ Cera Ruby series/Somany Bellis series. |
| 15 | S&F in repairs CP fancy type Angle valve 15mm dia (angle cock) cast copper alloy with wall flange. Make : Jaquar Opal Prime Series/ Cera Ruby series/Somany Bellis series |
| 16 | S&F in repair CP brass overhead shower square fancy type 100x100 mm with extension CP Arm pipes. Make : Cera/Jaquar/Somany |
| 17 | S&F in repair CP Health faucet telephonic type with 1.5m long flexible CP pipe. |
| 18 | S&F in repair brass chromium plated towel rail, 600mm long. |
| 19 | S&F in repair brass chromium plated towel ring fixed with screw in wall complete all as specified and directed. |
| 20 | S&F in repair brass chromium plated towel rack with hooks, 60cm long between flanges complete all as specified and directed. |
| 21 | S&F of tooth brush/paste tumbler holder fixed to walls with chromium plated brass screws. |
| 22 | S&F of Coat hook fixed to walls with chromium plated brass screws. |
| 23 | S&F PVC (SWR) 110mm dia pipes single socketed, in any length with rubber ring joints, fixed to walls/floors fixed in repair complete all as specified and directed. |
| 24 | S&F PVC (SWR) 75mm dia pipes single socketed, in any length with rubber ring joints, fixed to walls/floors fixed in repair complete all as specified and directed. |
| 25 | S&F PVC bends of 75 mm dia any radius diminishing pieces or tapers fixed in repair complete all as specified and directed. |
| 26 | S&F PVC bends of 110 mm dia any radius diminishing pieces or tapers fixed in repair complete all as specified and directed. |
| 27 | S&F PVC (SWR) floor trap 100mm dia, plain with grating including jointing with solvent cement fixed in repair complete all as specified and directed. |
| 28 | S&F in repair Grating square fitting of size 150mm made in two parts for smell and mosquito proofing with hole for waste pipe complete all as specified and directed. |
| 29 | S&F 15mm bore medium grade steel water tubing, galvanized (ISI Marked) with and including all fittings (ISI Marked) and jointed, tested and fixed complete to wall and ceiling or laid in floors etc complete including cutting, chasing in, taking up or down existing steel tubing pipe complete all as directed. |
| 30 | S&F 20mm bore medium grade steel water tubing, galvanized (ISI Marked) with and including all fittings (ISI Marked) and jointed, tested and fixed complete to wall and ceiling or laid in floors etc complete including taking up or down existing steel tubing pipe complete all as directed. |
| 31 | S&F 1000 Litres capacity rotational moulded polyethylene water storage tanks, three layered, ISI Marked (cylindrical vertical with closed top) hoisted and fixed in position, all as specified in SSR part I-2009 including 15/20mm dia PTMT ball valve complete set and dismantling of existing unserviceable tank and removing from site complete all as specified and directed |
| 32 | M&L for PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in sub base filling and mass concrete complete finished even and fair incl demolition of PCC all as specified and directed. |
| 33 | M&L for capsule pattern fully vitrified coloured tiles 9 to 10mm thick (Square or rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, laid in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with and including laying of 15 mm thick screed bed or bedding layer in CM 1:6 complete including dismantling of existing floor tiling including cement mortar bedding and removing rubbish off the premises complete all as directed. |
| 34 | M&L Drapery rod in any length, high strength stain less steel pipe of thickness 1.00mm having outer dia 25-28mm a pair of brackets & a pair of stainless steel finials, fixed in repair complete all as specified and directed. |
| 35 | S&F Pre-painted black colour galvalume aluminium Zinc coating AZ 150 GI based corrugated steel sheet 0.50mm thick of approved profile and make of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws etc fixed in repairs complete all as directed. |
| 36 | S&F Pre-painted black colour galvalume aluminium Zinc coating AZ 150 GI based pre profiled (matching with roof sheet) plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridges, gutter fixed in repairs complete all as directed by Engr-in-charge. |
| 37 | Dismantling existing timber scantling in any position.complete all as specified and directed. |
| 38 | S&F Rolled structural mild steel work as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed.(Fe-410-W (Gde E- 250) quality B) of approved primary producer. |
| 39 | M&L for Preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed |
| 40 | M&L for 15mm thick ready mix cement plaster on brick, concrete surfaces and wall/Ceiling surface finished even & fair, finishing curing scaffolding including taking down of existing cement plaster etc complete all as specified and directed. |
| 41 | M&L for Brick work with sub class 'B' bricks (old size) straight or curved on plan exc 6.00m mean radius built in cement mortar (1:6) including demolition of existing brick work complete all as specified and directed. |
| 42 | Demolition of cement concrete in ground floor and paving nexc 15cm thickness (below or above ground level) |
| 43 | M&L for 75mm thick PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in plinth protection or similar places, and finishing the surface even and smooth without using extra cement including making joints 12mm wide to the full depth of PCC at every 3 meters and at every change of direction and filling the same with sealing compound grade 'A' including necessary formwork etc concrete complete all as specified and directed |
| 44 | M & L applying two coat of Texture paint of approved make and any colour/shed including complete removal of old coating as per manufacture instruction complete all as specified. |
| 45 | M&L for applying 3mm thick damp proof wall care putty as per manufacturers instruction, Preparation of puttied wall / ceiling by mechanical sander/grinder and applying two coats of oil bound emulsion distemper over a coat of primer complete all as specified and directed. |
| 46 | M&L for Preparation of surfaces of wall / ceiling and applying two coats of weather coat exterior paint over a coat of primer and over a coat of 3mm thick white cement base water proof putty including sanding/grinding complete all as specified and directed. |
| 47 | S&F Door seal bottom for insect prevention with Carbon metal seal strip with rubber insulation, Anti rust, weather proof, soundproof for all door type, brown colour fixed to door with carbon screws complete all as directed. |
| 48 | M&L for 18-20mm thick zed black Granite work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) pointing in white cement (1:2) using marble dust and half rounding of exposed edges including taking down of existing shelf complete all as specified and directed. |
| 49 | S&F single extruded WPC louvers of approved colour and pattern and sample to be approved by GE for ceilings, interior wall panelling, etc. the louvers shall have dimensions of 2900mm x 160mm x 24mm with a tolerance of 5% fixed on GI grid and with 4mm supended hanger wire. The louvers base and PVC film shall be manufactured in India. The compostion shall include virgin polymer with a 'K' value of 58-60 (suspension grade), calcium carbonate, natural fibres (such as wood powder, rice husk, or wheat husk), and non-toxic additives, having class A category resistance to spread of flame criteria, louvers must be termite/borer proof, water/moisture proof and fire retardant complete all as directed. |
| 50 | M&L for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in surface channels and drains including Desludging/ cleaning of open drain of any depth by mechanically means and burring the sludge into the ground complete all as specified and directed. |
| 51 | M&L for taking down door and refixing in the same position and opening as directed including necessary door fittings and polishing complete all as specified and directed. |
| 52 | M&L for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 65 x 100 mm comprising of virgin PVC polymer of 'K' value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 53 | M&L for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/Chowkhat of size 65 x 125 mm single or double rebates as directed comprising of virgin PVC polymer of 'K' value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 54 | S&F factory made single extruded WPC (Wood Polymer Composite) solid both side prelaminated decorative type flush door shutter of size 35mm thick comprising of virgin polymer of 'K' value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. |
| 55 | M&L 35mm thick factory made solid WPC (Wood plastic composite) both side prelaminated gauged door shutter (single door piece to be used) consisting of density 650 kg/cum panelled with SS mosquito wire mesh and XTN aluminium mesh for additional strength and safety purpose in any number of division with brown wood grain texture, including stainless steel wire mesh be fixed with 15x15 Square tube in side rails with screwing 8x28 heat metal zink coated screws can be remove or fix again after changing of wire mesh when needed. The density shall be as per manufacturer instruction complete all as specified and directed. |
| 56 | S&F 300mm mild steel ordinary rat tail rod pattern spring including roller and roller plate fixed to wooden/mild steel chowkhat complete all as specified and directed. |
| 57 | Taking down chowkhats or frame with shutters (without taking off shutters from the frames) area n exc 1.5 Sqm each complete all as specified and directed |
| 58 | Taking down chowkhats or frame with shutters (without taking off shutters from the frames) area .exc 1.50 Sqm and n exc 4.00 sqm each complete all as specified and directed |
| 59 | M&L for aluminum alloy powder coated standard hollow section as mentioned below window frame (Bombay sliding) with two glazed shutter and one Nos wire gauged shutter sliding type, with aluminum sections as per Series-B (18mm) 3 track of Jindal section numbers for sliding windows, and glazed with tinted glass coloured glass 6mm thick, fixed with glazing clips, rubber beading / gasket anodised beading, screw and lock type 2 Nos aluminium handle of size 75mm and locking system including aluminium grill of 5mm thick, average width of aperture 50mm and SS wire cloth 0.46mm dia of wire and 1.40 aperture and provision of openable space for AC with 04 Nos of tower bolt etc complete all as specified and directed. |
| 60 | S&F aluminium powder coated door fixed on aluminium frame of section 47.62mm x 44.45x1.6 mm thick, shutter glazed with tinted glass 5mm thick/AC panel fixed with rubber gasket and aluminium strips as per standard method also rubber gasket at frame so as to make air tight with cast type handle aluminium anodised of 150mm size 2 Nos (One on each side of shutter) with hydraulic door closer universal type with aluminium tower bolt arrangement of standard make and locking arrangement with 6 levers mortise lock (brass body) including butt hinges, door stopper etc complete all as directed. |
| 61 | S&F aluminium powder coated frame for fixed partition of section 47.62mm x 44.45x1.6 mm thick, shutter glazed with tinted glass of approved make 5mm thick fixed with rubber gasket and aluminium strips as per standard method also rubber gasket at frame so as to make air tight all as per IS 737-1986 including aluminium grill of 5mm thick complete all as specified and directed. |
| 62 | S&F multi purpose wall mounted Cabinet Mirror ABS body of size 450x600 mm for bathroom fixed with screw on wall complete all as directed of approved sample and make. |
| 63 | M&L for welded steel wire fabric weight n exc 4kg/sqm fixed/welded to wood or steel members complete all as directed (weight per Sqm to be ascertained by a Board of Officer) |
| 64 | S&F Mild steel framed work such as grills, grating etc with end of bars shouldered and/ or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing and similar work complete all as specified and directed |
| 65 | S&F Butt hinges, 150 mm long, extruded stainless steel medium grade with galvanised mild steel hinge pin anodised and fixed complete all specified as directed |
| 66 | S&F 300mm long Stainless steel, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed |
| 67 | S&F 150mm extruded Stainless steel handles, fabricated type, complete all as specified and directed. |
| 68 | S&F 200mm long Stainless steel, barrel tower bolts of extruded section complete all as specified and directed |
| 69 | M&L for PCC 1:3:6 Type C-2 (using 40mm graded crushed stone aggregate) as in foundation of man hole incl demolition of existing cement concrete of any description complete all as specified and directed. |
| 70 | M&L for Cleaning the manhole up to 1.50m deep by rodding manually and removing the sludge from manhole and completely cleaning by flushing with water etc complete, sludge shall be removed from IMA premises and spreading of lime for stop foul smell complete all as specified and directed. |
| 71 | M&L for Cleaning the sewage line up to 150mm dia by rodding manually and removing the sludge and completely cleaning by flushing with water etc complete , sludge shall be buried into ground and covered with the enough quantity of lime to stop the foul smell complete all as specified and directed. |
| 72 | M&L in repair for DWC (Double wall coruggated) HDPE pipes of size 150mm (ID) confirming to IS 16098 Part-II of strength/stiffness class SN 8 laid in trenches on concrete bed to level/ gadient, jointing as per manufacturers instructions including jointing accessories as required complete all as specified and directed. |
| 73 | M&L for treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12 mm dia holes with cement mortar 1:2 to match the existing floors complete all as directed |
| 74 | S&F 4mm thick E-board false ceiling (Classic) including M&L for galvanised colour coated snap grid frame for false ceiling, size of grid 605x 605mm fixed with 1.6 mm dia GI wire suspenders one end tied to roof members and other end connected to main tee of grid framework by means of 4mm dia wire including taking down existing boards complete all as directed. |
| 75 | Repairing to existing door/ window chajjas upto 3.0m span and width 1.0m by demolition/ scrapping of damaged portion and preparing the surfaces by providing 50mm thick cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) including finishing the surface by rendering 10 mm thick plaster in CM 1:3 and finished even and smooth surface using extra cement over concrete surface and PCC benching complete all as directed. |
| 76 | M&L for R.C.C 1:2:4 nominal mix type B1 (20mm graded agg) Slabs supported on walls, beams and columns in floors, roofs, canopies, deck slabs and in shelves and the like complete all including demolition of existing slabs and necessary formworks. |
| 77 | M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 78 | M&L for obliterating old writing of any description, n exc 01 sqm with black paint in the form of diamond shape of size not exc 30x30cm and writing letters or figures (Block, Roman Italic or Indian), stops, commas, short lines, dashes, hyphens, brackets etc minimum of 10 cm height (total letters not exc 06 Nos) colour as decided by Engr -in charge complete all as specified and directed. |
| 79 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface of walls, floors, etc. |
| 80 | Taking down existing oldCeiling fan/ Exhaust fan and deposit to MES yard of any size and capacity all as directed. |
| 81 | Taking down existing old Water Heater (Geyser) and deposit to MES yard of any size and capacity all as directed. |
| 82 | Taking down old U/S main switches, Sheet metal enclosures DB including MCCBs, MCBs etc including making good to the disturbed surface of wall all as directed. |
| 83 | Taking down old unsv T/L of any size and capacity all as directed. |
| 84 | Taking down existing ceiling fan of any capacity and make serviceable by replacing unsv parts and preparation of old painted surface body and blades of ceiling fan of any capacity ,cleaning foreign material ,filling cavaties atc and painting with one coat of synthetic enammeled paint by spray painting and marking MES No. with paint and kept in safe custody and refixing at site after compltion of bldg work. |
| 85 | Taking down carefully submain wiring including all accessories without disturbing existing wiring fittings fixtures etc and making good to the disturbed surfaces all as directed and as specified in any type and size all as directed. Please Enable Macros to View BoQ information |
| 86 | Taking down carefully submain wiring including all accessories without disturbing existing wiring fittings fixtures etc and making good to the disturbed surfaces all as directed and as specified in any type and size all as directed. Please Enable Macros to View BoQ information |