| Sl. No. | Item Description |
| 1 | Civil Work |
| 2 | Construction of Aviation Museum at Civil Aerodrome, Patiala |
| 3 | Excavation in Soil (any type) using HydraulicExcavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts and combined lead upto 30m. |
| 4 | Providing and applying Anti Termite Treatment using pre constructional chemical treatment measures as per IS - 6313 - 2001 (Part 2) & using Chemical containg chloropyrifos systemic insecticide diluted to manufacturer's specifications (i) In foundation pits, by treating the bottom & sides upto height of 300mm by uniformly spraying solution @ 5 Litre / Sqm (ii) In the refill earth on both sides of all built up walls @7.5 Litre / Running meter ( width - 300 mm, depth- 450 mm ) (iii) Before laying the floor, by uniformly sprinkling the top surface of the consolidated earth within the outer perimeter @ 5 Litre solution per Sqm. |
| 5 | Cement Concrete 1:4:8 with stone ballast of size. Using concrete mixer volumetric type. |
| 6 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 7 | Centering and shuttering for columns (circular or curved in plain) |
| 8 | Centering and shuttering for columns (Square or rectangular or poly gonal in plain) |
| 9 | Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering) including attached pilasters, buttresses etc when curved. |
| 10 | Centring and shuttering for stair cases with sloping with soffits including risers and stringers. |
| 11 | First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. |
| 12 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth |
| 13 | Damp proof course 4 cm thick of cement concrete 1 : 2 : 4 with 2 coats of bitument 20/30 penetration at 1.65 kg per Sqm. laid hot and sanded. |
| 14 | Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels. |
| 15 | Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 16 | Extra rate for shuttering in each subsequent storey above the first. Storey work done in subsequent storey above the first storey up to height of 4 metres or part thereof up to the roof top level of that storey-For first floor |
| 17 | Extra rate for shuttering in each subsequent storey above the first. Storey work done in subsequent storey above the first storey up to height of 4 metres or part thereof up to the roof top level of that storey-For Second floor |
| 18 | Extra rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof. |
| 19 | Extra rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof. |
| 20 | Extra rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof. |
| 21 | Extra rate for shuttering work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof. |
| 22 | Providing and laying in super structure for first storey factory made with vibro-hydraulic compaction machine precast Hollow block of cement concrete setting in position with cement mortar 1:3 (1 cement:3 course sand ) including cost of hosting, centering and shuttering complete as per IS:2185 (Part-1): 2005. |
| 23 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. |
| 24 | Extra for work done in additional storey upto 4 metre above the top of structural roof of lower storey for Brick Work/ Concrete Block/ Clay Block-For First Floor |
| 25 | Extra for work done in additional storey upto 4 metre above the top of structural roof of lower storey for Brick Work/ Concrete Block/ Clay Block-For Second Floor |
| 26 | Extra for work done in additional storey upto 4 metre above the top of structural roof of lower storey for Brick Work/ Concrete Block/ Clay Block-For Third Floor |
| 27 | Extra for c above 4 meters (where any single storey exceeds 4 metres in height) for every additional height of 2 metres or part thereof for Brick Work/ Concrete Block/ Clay Block. |
| 28 | Extra for c above 4 meters (where any single storey exceeds 4 metres in height) for every additional height of 2 metres or part thereof for Brick Work/ Concrete Block/ Clay Block. |
| 29 | Providing and fixing thermal insulation on external wall with CFC Free closed cell, high performance rigid Polyurethane Foam(PUF) Insulation Slab conforming to IS: 12436 having density not less than 36±2 kg/m3, thermal conductivity (K-value) 0.021 W/m.K measured at 10 deg. C mean temperature and classified as “not easily ignitable” per BS: 476, Part-5, fixed with the help of adhesive (patch applied) & PVC fastener to the wall surface and all complete as per the instruction of engineer-in-charge |
| 30 | 115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1 :4 cement sand mortar in super structure. |
| 31 | Extra for 115mm/100mm thick walls for additional storey upto 4 meters above the top of structural roof of lower storey for Brick Work/ Concrete Block/ Clay Block. |
| 32 | Reinforced cement concrete M-25 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure |
| 33 | Extra for RCC/PCC work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof. |
| 34 | Extra for RCC/PCC work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof. |
| 35 | Extra for RCC/PCC work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof. |
| 36 | Extra for RCC/PCC work done above 4 metres height (where any single storey exceeds 4 metres in height) for every additional height of 1 metres or part thereof. |
| 37 | Extra for using computerised concrete batch mixing plant including carriage by transit mixer within 1 km lead (note: where concrete mixer is already included in the rate the same shall be deducted ) |
| 38 | Extra for pumping charges of Batch Mix Concrete / Ready mix conrete work (RMC) |
| 39 | Extra rate for enhancement in pumping power, addition of pipe length, scaffolding for handling the pipe arrangement for pumping of concrete in subsequent storey above the below storey up to height of 4 meters or part there of up to the roof top level of that storey- For First Floor |
| 40 | Extra rate for enhancement in pumping power, addition of pipe length, scaffolding for handling the pipe arrangement for pumping of concrete in subsequent storey above the below storey up to height of 4 meters or part there of up to the roof top level of that storey- For Second Floor |
| 41 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.0 works, where not including in the complete rate of RCC including bending and binding placing in position complete |
| 42 | Extra for work done in each subsequent storey above the first storey for item No. 18.17, 18.18, 18.19-For first floor |
| 43 | Extra for work done in each subsequent storey above the first storey for item No. 18.17, 18.18, 18.19-For Second floor |
| 44 | Steel work in built up tubular pipes (round, square or rectangular hollow tubes etc. ISI Marked) for flat shed (ie.Where no truss work is involved) including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 45 | Steel work in built up tubular (round, square or rectangular hollow tubes etc. ISI Marked) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete having span:- |
| 46 | Corrugated G.I. Sheet roofing 0.80 mm thick fixed with galvanized iron J or L hooks 10mm dia, G.I. Limpot and bitumen washers complete excluding the cost of purling rafters and trusses |
| 47 | G.I. Sheet gutters 0.80mm thick semicircluar 15cm diametre including fixing with clamps and making connections with rain water pipes. |
| 48 | Providing laying Foam concrete on GI Sheet roofingTopping |
| 49 | Structural steel work in angles, tees, flats, riveted, including cutting, fixing all gusset plates, bolts, nuts, rivets etc. with hoisting and erecting in position. |
| 50 | Nuts & Bolts of all sizes and length required |
| 51 | Mild steel requirement for RCC work where not including the complete rate of RCC including bending, binding and placing in position complete in all respects. |
| 52 | Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge. |
| 53 | 10mm thick Cement Plaster 1:4 |
| 54 | 12.5mm thick cement plaster 1:5. |
| 55 | 20 mm thick cement plaster 1:5 in two coats work. |
| 56 | Extra for Plastering in each subsequent storey above the first storey upto 4 metre above plinth level-First floor |
| 57 | Extra for Plastering in each subsequent storey above the first storey upto 4 metre above plinth level-Second floor |
| 58 | Extra for Plastering where any single storey height exceeds 4 metres in height for every additional height of 2 metres or part thereof.(Internal or External) |
| 59 | Extra for Plastering where any single storey height exceeds 4 metres in height for every additional height of 2 metres or part thereof.(Internal or External) |
| 60 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating leadupto 30 metres |
| 61 | Sand filling under floor and in wells of bridge foundation including handling withing 100 metres |
| 62 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand or stone filling. |
| 63 | Construction of un-reinforced M-35 grade concrete pavement with dowel jointed over a prepared sub base with 43 grade OPC cement with Fly ash (subject to maximum 25% of cement content) of concrete, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a fully computerised batch mix plant as per approved mix design, transported to site in transit mixer with lead up to 10 km. laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per clause 602 of MORT&H 5th Revision |
| 64 | Providing & fixing 18mm to 20mm thick marble strips in joints of terrazo / cement concrete floors. |
| 65 | Conglomerate floor 40mm thick cement concrete topping 1:2:4. |
| 66 | Floating coat of 1:5mm thick neat cement laid in one operation to the topping |
| 67 | Providing & laying Epoxy Flooring 6mm thick for Hangar Floors |
| 68 | Screed of 50mm thick cement concrete 1:8:16 to be laid below the topping using mechanical mixer for mixing of material |
| 69 | Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) |
| 70 | Providing and Laying Tactile Flooring full body vitrified , low water absorption below 5%, having excellent slip resistance , very dense, durable and abrasion resistant, solid through colour, fade proof, highly chemical and stain resistance unglazed finish porcelain tile of size 300mm x 300mm x 10mm + 5mm thick, approved profile design, Tec-button/Tec-liner laid in ordinary grey cement and on 20mm thick bed of cement mortar 1:3 filling neat cement slurry between joints with White Cement containing pigment to match the shade complete in all respect. (Tile design and pattern will be as per guidelines issued for persons with disability) |
| 71 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. |
| 72 | Providing and laying flamed finish Granite stone 18mm thick in flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : |
| 73 | Extra Labour for projected nosing of Stair Case any shape and design |
| 74 | Providing and fixing G.I. Sheet 0.80mm thick sliding shutters with 40mmx40mmx6mm angle iron frame with diagonal braces 3.15mm gusset plates at the junctions, hooks at top and 25mm dia pulleys at bottom and 40mmx40mmx25mm dia pulleys at bottom and 40mx40mmx6mm angle iron top and bottom guides including locking arrangement with handles etc. complete |
| 75 | Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. |
| 76 | Supply & Fixing of door frames (Chowkhats) consisting frame fabricated from sheet roll formed out of 1.2mm thick galvanized sheet as per IS:277 (base steel as per IS: 513) with zinc of 120gm/sqm & Powder coated with pure Polyster powder upto 50 micrones (as per approved colour) , 3 Nos 100mm butt-hinges 2mm thick, 6 Nos 1.2mm thick CRCA electroplated stiffner, 6 Nos M.S hold fast with split and tail welded to stiffner plate 200mm long, Receiver for aldrop, M.S tie rod 50mm x 25mm to be fixed at bottom finished with powder coated total thickness of coating 0.60mm of approved shade, fixed in position, including the cost of cement concrete for 1:2:4 for fixing lugs complete in all respects as per drawing, design, specification & entire stasfication of Enginner-in-Charge. |
| 77 | Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position. (Code IS 2022-1(1999)). |
| 78 | Providing and fixing 12mm thick toughned Glass in front windows of size 10'x13' |
| 79 | Providing and fixing 8mm thick toughned Glass in front windows of size |
| 80 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge |
| 81 | Supply & Fixing of Window shutter consisting frame fabricated from sheet roll formed out of 0.58mm thick galvanished sheet (base steel as per IS : 513) with zinc of 120gm/sqm steel sheet pre coated (as per approved colour) with polyster paint of 12-16 micrones thickness under coat of EPDXY primer & back coated with ALKYD backer of 5-7 micrones total thickness of. coating 0.58mm of approved shade, fixed in position fixed in position by means of screws, complete in all respects as per drawing, design, specification & entire stasfication of Enginner-in-Charge. |
| 82 | Wire Mesh Windows shutter Section 40mm x 20mm with S.S wire mesh 32 guage flymesh with 144 holes per square inch |
| 83 | Providing and fixing glazing in door, window, ventilator shutters and partitions etc. complete as per the architectural drawings and the directions of engineer-in-charge , (Cost of Gasket /beading shall be paid as per respective item). |
| 84 | Extra for providing and fixing steel bidding and approved steel tube beeding size 12mm x 6mm 18 gauge |
| 85 | Providing and fixing Stainless Steel pipe and fitting of grade A ISI-304 as per IS standard 3448 complete with press type fitting (fitting shall be paid for separately) i/c fixing of the pipe with clamps at 1.00 m spacing including cutting and making good the walls including testing of joints complete as per direction of Engineer-in- charge. (The pipe length inserted in the fitting shall not be measured for payment) |
| 86 | Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including: |
| 87 | (a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminum cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including |
| 88 | (b) Fabricating and supplying serrated M.S. hot dip galvanised / aluminum alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimensional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers. |
| 89 | (c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass. |
| 90 | (d) Providing and fixing in position flashings of solid aluminum sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. |
| 91 | (e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminum grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handingover of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the aproved shop drawings and as directed by the engineering-Charge. |
| 92 | Note:- 1. The cost of providing extruded aluminum frames, shadow boxes, extruded aluminum section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places. |
| 93 | Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from thecertified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & echnologies,India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work.Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or by any other accreditation body which operates in accordance with ISO/ IEC 17011 and accredits labs as per ISO/ IEC 17025. |
| 94 | 1. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) asper ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range up to 2000 ml.3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml4. Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind pressure without any failure) as per ASTME-330- 10 testing method for a range upto 50 mm5. Seismic Movement Test (upto 30 mm) as per AMA 501.4-09 testing method for Qualitative test, Tests to be conducted on site.6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml |
| 95 | Providing, assembling, supplying and fixing vision glass panels (IGUs) comprising of hermetically-sealed 6- 12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthened clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shadingcoefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. |
| 96 | Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) |
| 97 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 98 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : |
| 99 | Providing and Laying Out Door precast designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3 (1 ordinary cement: 3 fine sand), joints grouted with white cement slurry containing pigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer-in-charge. |
| 100 | Providing & fixing 16 gauge stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainless steel pipe, Balusters of 40mm dia Stainless steel pipe and guard 3 Nos of 15mm dia Stainless Steel pipe complete in all respect. |
| 101 | Terracing consisting of tiles 22.86 cm x 11.43 cm x 3.81 cm laid over 25mm mud plaster, 75 mm mud filling on another layer of 25 mm mud plaster including two coats of bitumen laid hot @ 1.65 Kg. per Sqm. on top of R.C.C slab including grouting with cement sand mortar 1:4 and top surface to be left clear after wire brushing etc. |
| 102 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 103 | Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16 |
| 104 | Bottom khurra on ground 1.2m 0.6m consisting of bricks on edge laid in cement mortar 1:3 over 7.5 cm cement concret 1:8:16 including 12.5mm thick cement plaster 1:3 |
| 105 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 2.50 kgf / cm²) conforming to IS : 4985, including jointing with seal ring (i) Single socketed pipes. |
| 106 | Providing and fixing 160 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. |
| 107 | Providing and fixing 160 mm dia. U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. |
| 108 | Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete. |
| 109 | Applying priming coat with metal primer on new steel or iron work including preparation of surface |
| 110 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 111 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 112 | Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface |
| 113 | Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats) |
| 114 | Finishing walls with textured exterior paint of required shade with two or more coats applied @ 3.28 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 115 | Providing and fixing mineral fibre false ceiling tiles ( NRC 0.55 to 0.6) at all heights upto 4 mtr. of size 595X595x16 mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. |
| 116 | Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 117 | Disposal of Excavated earth with an av.lead of 1.00 km (As excavated earth is not usable under floor) |
| 118 | Providing and fixing of LED Sign Boards with Acrylic name plates |
| 119 | Renovation of Hanger No. 5 |
| 120 | Stripping and stacking slate or tiles of a roof. |
| 121 | Dismantling concrete, Cement concrete plain1:2:4 mix |
| 122 | Dismantling brick work tile, masonry or tile lining |
| 123 | Removing doors and windows together with the dismantling of walls |
| 124 | Scraping |
| 125 | Dismantling concrete, Cement concrete plain1:2:4 mix |
| 126 | Dismantling concrete, Cement concrete plain 1:4:8 or 1:5:10 |
| 127 | Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled. |
| 128 | Dismantling concrete |
| 129 | First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level. |
| 130 | 12.5mm thick cement plaster 1:5. |
| 131 | 20 mm thick cement plaster 1:5 in two coats work. |
| 132 | Providing and applying Anti Termite Treatment using pre constructional chemical treatment measures as per IS - 6313 - 2001 ( Part 2 ) & using Chemical containg chloropyrifos systemic insecticide diluted to manufacturer's specifications (i) In foundation pits, by treating the bottom & sides upto height of 300mm by uniformly spraying solution @ 5 Litre / Sqm (ii) In the refill earth on both sides of all built up walls @7.5 Litre / Running meter ( width - 300 mm, depth - 450 mm ) (iii) Before laying the floor, by uniformly sprinkling the top surface of the consolidated earth within the outer perimeter @ 5 Litre solution per Sqm. |
| 133 | Base course of floor consisting of 100mm thick cement cocrete 1:8:16 and 100mm sand or stone filling. |
| 134 | Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.) |
| 135 | Extra Cost for using darker fast shade Vitrified or Rectified Tiles instead of lighter shades. |
| 136 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. |
| 137 | Cement Concrete 1:4:8 with stone ballast of size. Using concrete mixer volumetric type. |
| 138 | Construction of un-reinforced M-35 grade concrete pavement with dowel jointed over a prepared sub base with 43 grade OPC cement with Fly ash (subject to maximum 25% of cement content) of concrete, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a fully computerised batch mix plant as per approved mix design, transported to site in transit mixer with lead up to 10 km. laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per clause 602 of MORT&H 5th Revision |
| 139 | Providing & fixing 18mm to 20mm thick marble strips in joints of terrazo / cement concrete floors. |
| 140 | Floating coat of 1:5mm thick neat cement laid in one operation to the topping |
| 141 | Cement rendering on plaster 1mm thick |
| 142 | Terracing consisting of tiles 22.86 cm x 11.43 cm x 3.81 cm laid over 25mm mud plaster, 75 mm mud filling on another layer of 25 mm mud plaster including two coats of bitumen laid hot @ 1.65 Kg. per Sqm. on top of R.C.C slab including grouting with cement sand mortar 1:4 and top surface to be left clear after wire brushing etc. |
| 143 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 144 | Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. |
| 145 | Supplying and fixing of Japani sheet frames (Chowkat) consisting of 18 gauge (1.25mm) thick steel sheet of the specified section (standard design latest), including iron lugs (hold fasts) iron hinges conforming to PWD specifications including bolts for fixing steps, lock notch provision for receiving tower bolts and finished, fixed in position including the cost of cement concrete 1:3:6 for filling in the frame and cement concrete 1:2:4 for lugs complete to the satisfaction of Engineer-in-charge. |
| 146 | Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position. (Code IS 2022-1(1999)). |
| 147 | Providing & laying Epoxy Flooring 6mm thick for Hangar Floors |
| 148 | Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16 |
| 149 | Bottom Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16 |
| 150 | Providing and fixing Stainless Steel pipe and fitting of grade A ISI-304 as per IS standard 3448 complete with press type fitting (fitting shall be paid for separately) i/c fixing of the pipe with clamps at 1.00 m spacing including cutting and making good the walls including testing of joints complete as per direction of Engineer-in- charge. (The pipe length inserted in the fitting shall not be measured for payment) |
| 151 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminum snap beading shall be paid in basic item) |
| 152 | Steel work in built up tubular pipes (round, square or rectangular hollow tubes etc. ISI Marked) for flat shed (ie.Where no truss work is involved) including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 153 | Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge. |
| 154 | Extra for providing and fixing steel bidding and approved steel tube beeding size 12mm x 6mm 18 gauge |
| 155 | Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete. |
| 156 | Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc. |
| 157 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 158 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish |
| 159 | Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface |
| 160 | Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats) |
| 161 | Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 162 | Providing and fixing of LED Sign Boards with Acrylic name plates |
| 163 | Corrugated G.I. Sheet roofing 0.80 mm thick fixed with galvanized iron J or L hooks 10mm dia, G.I. Limpot and bitumen washers complete excluding the cost of purling rafters and trusses |
| 164 | Structural steel work in angles, tees, flats, riveted, including cutting, fixing all gusset plates, bolts, nuts, rivets etc. with hoisting and erecting in position. |
| 165 | Providing laying Foam concrete on GI Sheet roofing Topping |
| 166 | Providing and fixing mineral fibre false ceiling tiles ( NRC 0.55 to 0.6) at all heights upto 4 mtr. of size 595X595x16 mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. |
| 167 | Disposal of Excavated earth/Malba with an av.lead of 1.00 km |
| 168 | Area of Parking/Outer Development |
| 169 | Dismantling concrete, Cement concrete plain1:2:4 mix |
| 170 | Excavation in Soil (any type) using HydraulicExcavator CK 90 with hydraulic excavator of 0.9 cum bucket capacity including cutting, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, including all lifts |
| 171 | Construction of granular sub-base by providing material as per grading-III (Table 400-I of MORT&H 5th revision), mixing in a mechanical mix plant at OMC, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per technical clause 401 of MORT&H specifications |
| 172 | Cement Concrete 1:4:8 with stone ballast of size. Using concrete mixer volumetric type. |
| 173 | Construction of un-reinforced M-35 grade concrete pavement with dowel jointed over a prepared sub base with 43 grade OPC cement with Fly ash (subject to maximum 25% of cement content) of concrete, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a fully computerised batch mix plant as per approved mix design, transported to site in transit mixer with lead up to 10 km. laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per clause 602 of MORT&H 5th Revision |
| 174 | Providing and laying facory made rubber moulded smooth finish cement concrete Kerb M-20 grade 250mm high with bottom width 165mm anf top width 115mm made over strong vibratory table and fixing with cement mortar 1:2 as per MORT&H Specifications |
| 175 | Preparation of plastered surfaces for distempering including surface, applying filling with approved quality filler consisting of plaster of paris and chalk mitti including finishing the surface to the required finish complete |
| 176 | Applying priming coat with metal primer on new steel or iron work including preparation ofsurface. |
| 177 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 178 | Advance Direction sign board 1200x1800mm rectangular as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 – 09 and as per IRC 67 – 2012. fixed over 4mm thick Aluminium Composite Material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on two square hollow steel section post 60x60x3.2mm conforming to IS 4923 firmly fixed to ground in foundation concrete M-25 of size 0.60x0.60x0.75m for vertical post complete as per clause 801 of MORT&H specifications. Supplier shall provide a warranty as per clause6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67-2012 . |
| 179 | Place Identification sign board 900x600mm rectangular as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 – 09 and as per IRC 67 – 2012 fixed over 4mm thick aluminium Composite material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on two square hollow steel section post 60x60x3.2mm conforming to IS 4923 firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.60m for vertical post complete as per clause 801 of MORT&H specifications. Supplier shall provide a warranty as per clause6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67-2012 . |
| 180 | Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position |
| 181 | Disposal of Excavated earth/Malba with an av.lead of 1.00 km |
| 182 | Public Health work |
| 183 | Sub work-1 |
| 184 | Sub head-1 Water Supply System |
| 185 | CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-inCharge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. |
| 186 | CPVC SDR 11 Pipe & fitting 20 mm o/d |
| 187 | SDR 11 CPVC pipes & fittings 25mm o/d |
| 188 | Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition. |
| 189 | Size 75 mm x 75 mm |
| 190 | Providing, fixing and jointing CPVC Union Couplings(of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect. Union 25 mm o/d complete |
| 191 | Union 40 mm o/d complete |
| 192 | Providing, fixing and jointing CPVC Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete. |
| 193 | 25mm i/d Brass Ball valves |
| 194 | 40mm i/d Brass Ball valves |
| 195 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer - in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. |
| 196 | Triple Layer Tanks |
| 197 | 2000 Ltr x 5 nos. |
| 198 | Construction of Plateform complete as per specification & as desired by Enginer-in-charge |
| 199 | For 2000 ltr Water Tank |
| 200 | Providing & fixing in position CPVC.tank nipple of approved make to the approval of engineer in charge in PVC water storage tanks complete in all respects. |
| 201 | .CPVC tank nipple 40 mm i/d |
| 202 | Providing and fixing in position automatic brass ball valves in tanks. |
| 203 | 40 mm i/d Brass ball valve with plastic ball with G.I. socket |
| 204 | Sub head-2 Sewerage System |
| 205 | Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. |
| 206 | 110mm o/d single socket SWR UPVC pipe lines laid complete |
| 207 | Providingand fixing inpositionSWR UPVC special for soilwastevent or anti syphonage pipes as per as per IS- 14735 including cuttingandwastageetc.cuttingholesinwalls roofs or floors etc. andmaking good to its original conditionbut excluding cost of lead joining.For 110mm o/d pipes |
| 208 | For 110mm o/d pipes |
| 209 | Elbow 90 Degree (All side socketed) bend 110 mm |
| 210 | Door Elbow 90 Degree (All side socketed) door bend 110mm |
| 211 | Single Tee With Door |
| 212 | Single Tee |
| 213 | P Trap/Floor Trap 110mm x 110mm |
| 214 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floatingcoat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100 mm thick cement concrete topping50mmthickwith455mmx 455mm, 455mm x 610mm inside R.C.C. inspection chambercoverandframe(Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. 450mmx600mminsidewith455mmx 610mm cover and frame light duty double sea |
| 215 | Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm. |
| 216 | Sub head-3 wall / Floor tile work |
| 217 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x600 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 218 | Providing and laying Rectified Porcelin floor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring complete . |
| 219 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40 mm gauge and 100mm sand filling using mechanical mixer for mixing of material |
| 220 | Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps. |
| 221 | Providing and fixing tiled false ceiling at height upto 4 mtr of specified materials of size 595x595 mm ( GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece..) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making,opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dashfasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all Tsections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and asdirected by Engineer-in-charge. |
| 222 | Sub head-4 Sanitary Fixtures & CP Brass Fittings |
| 223 | Providing and fixing in position set of EWC and WHB size 46x36 cm for Handicapped person of approved make (to the approval of the Engineer-in-charge) consisting of matching cistern, one pair mounting brackets, seat cover, one no. hinges rail 76cm and 4 no. grab rails 60cm complete in all respect and to the entire satisfaction of Engineer-in-charge.Divyagan Toilet |
| 224 | Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 225 | Providing and fixing jet spray with 2'-6\\" long PVC pipe.With C.P. Brass nut |
| 226 | Providing and fixing Stainless steel healthfaucet complete in all respect. |
| 227 | Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect. |
| 228 | C.P. brass Bib cock with Wall flange |
| 229 | Providing and fixing in position C.P. Brass Auto close Pillar Cock of approved make (to the approval of Engineer-in-charge) |
| 230 | C.P. Brass Pillar Cock foam flow |
| 231 | Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-in- charge )with various fixtures complete in all respect. C.P. Brass extension piece, 25mm long to 50mm long |
| 232 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect. |
| 233 | Size 630mm x 500mm (above counter oval) |
| 234 | Providing and fixing in position premium range towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect. |
| 235 | C.P brass towel ring square |
| 236 | Providing & Fixing in postion stop cock /Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 237 | C.P.brass 15mm stop cock Male and female end |
| 238 | C.P.brass 15mm Concealed stop cock with flange. |
| 239 | Providing & Fixing in position 5mm thick bevelled edgemirror of superior glass (of approvedmake) completewith 4mm thick hardboardbacking fixed inwithrawl plugs 50 mm, C.P.brass screws and washer sand S/S Studs on top complete in all respect (as required by the Engineer-in- Charge)Size 450mmx600mm or any other size |
| 240 | Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect. |
| 241 | C.P. Brass khunti with 4 pegs |
| 242 | Providing and fixing in position vitreousChinaware white lIndian make large flatback orangular lipped front urinal 375x390x590 mm of approved make (to the approval of the Engineer-in-charge) consistingofC.P.brass Urinal waste Coupling dome type 32mm outer length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tube connection 300 mm long complete. |
| 243 | Vitreous white Chinaware Partition Large partition size 75x16.5x 36.5 cm |
| 244 | Providing and fixing in position SS Grating with frame of approved make (to the approval of engineer in charge) complete in all respects. |
| 245 | Providing & fixing in position PVC flexible tube connection of approved make to the approval of engineer in charge complete in all respects. |
| 246 | PVC tube connection of size 15 mm x450 mm with C.P. Brass nut |
| 247 | Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect. |
| 248 | Providing and fixing P.V.C Waste PipeCollapsiable 32mm complete in all respect. |
| 249 | Sub head-5 Water cooler & RO |
| 250 | Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect. |
| 251 | Water Cooler Semi Steel Body 80/120 ltr Capacity without Stablizer |
| 252 | Providing & fixing in position Commercial RO without reservoir with four no cartridge/ membrane having flow rate 50 ltr/hr with 6 stage purification process of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect. |
| 253 | Electrical work |
| 254 | Providing Internal Electrical Installations: |
| 255 | POINT WIRING: |
| 256 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 257 | Wiring fan point (with fan box) |
| 258 | Wiring light point |
| 259 | Wiring call-bell point |
| 260 | Wiring 6 Amp. wall socket point |
| 261 | Wiring 6 Amp. Plug control comprising wall socket point |
| 262 | Wiring 16/20 amp. power plug control point |
| 263 | Wiring light point without control switch. |
| 264 | Wiring light point with double control switches. |
| 265 | RECESSED COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 266 | Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16 Amp. switch with indicator and 1No. blanking plate (Modular accessories). |
| 267 | RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):- |
| 268 | Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height. |
| 269 | SUPPLY AND ERECTION OF WIRING ACCESSORIES:Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.:- |
| 270 | Ceiling Rose (Flush Piano type) |
| 271 | Call Bell 220/230 volts AC Ding Dong |
| 272 | LED'S FIXTURES & FANS: |
| 273 | Supply and erection of Slim Recessed mounted, Round downlighter 18 watt with Pressure die cast aluminium housing & polycarbonate diffuser with surge protection 10KV and efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 %, housing & driver shall be of same brand, supported with LM 79 reports not more than 2 years old from NABL /UL accredited laboratory complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. The certification and specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. |
| 274 | Supply and erection of LED batten 20 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. |
| 275 | Supply and erection of LED batten 40 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. |
| 276 | Supply and erection of Recessed mounted 36watt LED panel (including LED driver) with CRCA sheet having efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory. |
| 277 | Supply and erection of Projected/ Spot/ Focus/COB surface LED Light 30W Cylindrical (including LED driver) with CRCA sheet having efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 278 | Supply and erection of Projected/ Spot/ Focus/COB surface LED Light 30W Cylindrical with track accessories (including LED driver) with CRCA sheet having efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 279 | Supply and erection of Circular LED Highbay Light 80 watt AC supply voltage 140-270 volts, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED (with wattage 1 to 5 watt) with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No: AT/2021/GL/1410-1422 Dated: 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab. |
| 280 | Supply and erection of BEE 3-Star rating AC Ceiling Fan 1200mm (48\\") suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body, 3Nos. of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air deleivery of 210 CMM (approx.). The rated speed of the the product must be minimum of 300 revolutions per minute and 5Nos. of speeds. The product should have a manufcaturer's guarantee /warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer in-charge at site. |
| 281 | HVLS FAN: |
| 282 | Supply and erection of HVLS Fan 24' (7.3m), 5 Blades, 6063T6 Aluminum fanricated, 2.0 H.P, IE2 high efficiency, 230/400VAC split voltage motor, Enclosed Fan-Cooled (TEFC) with an IP55 enclosure rating, double coated magnetic wire insulation, Class H, Inverter/vector duty insulation system shall conform to NEMA MG1-2006 (or equivalent IEC standard), aluminium blades, coverage efficiency > 25 ft² / watt, Aerofoil shaped with a minimum blade width of 215mm from nose to trailing tip, Each Blade shall be affixed to a solid Powder coated Steel Hub each secured with minimum three zinc coated bolts, lock nuts and lock washers, HVLS fan control should include a factory programmed CE & UL Listed, VFD in an IP54 enclosure to provide a soft-start for the fan, variable speed control capability, current limit & motor overload protection for the fan, Fan control system with Limb DC Choke for Harmonics reduction meeting EN 61000-3-12 Standard, Min 1 Line Alphanumeric Keypad with Password protection facility, Built in PID Control, Efficiency 98% or above with built-in chokes & amp, EMC Filter, Support MODBUS & amp., Metasys N2 communication by default, Cascade control feature & amp., Fire-override mode, Sleep mode, Faults & Alarms : IGBT Over temperature, Input Phase loss, Voltage imbalance, output short circuit, Over current, Over voltage & Under voltage etc., complete in all respect as approved and desired by the Engineer in-charges at site. |
| 283 | Supply and erection of Heavy duty Exhaust Fan 300mm, 900RPM with aluminium louver shutter, double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site. |
| 284 | OCCUPANCY SENSORS: |
| 285 | Supply and erection of Ceiling mounted Occupancy based PIR sensor (360° detection angle motion detector) with installation height 3mts, 8.5 Amps resistive load, Detection dia 8M, time delay - 5s to 59 mins , Light level threshold - 5 to 1275 Lux, IP - 20, Sensitivity Adjustment, Walk LED test, with additional options like walkthrough, daylight set point, vacancy complete in all respect as approved and desired by the Engineer in-charges at site. |
| 286 | SUSPENSION RODS FOR CEILING FANS: |
| 287 | HEAVY GUAGE WELDED CONDUIT PIPES:Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- |
| 288 | Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), white painted suspension rod for ceiling fan. |
| 289 | CONDUIT PIPE & COPPER WIRES: |
| 290 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 291 | Heavy gauge PVC conduit pipe 20mm dia. (ISI marked) Flushed |
| 292 | Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed |
| 293 | Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) On-Surface |
| 294 | Heavy gauge PVC conduit pipe 32mm dia. (ISI marked) Flushed |
| 295 | Heavy gauge PVC conduit pipe 40mm dia. (ISI marked) Flushed |
| 296 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 297 | Overall size 1sq.mm (Un-sheathed) |
| 298 | Overall size 1.5sq.mm (Un-sheathed) |
| 299 | Overall size 2.5sq.mm (Un-sheathed) |
| 300 | Overall size 4sq.mm (Un-sheathed) |
| 301 | Overall size 6sq.mm (Un-sheathed) |
| 302 | Overall size 10sq.mm (Un-sheathed) |
| 303 | Overall size 16sq.mm (Un-sheathed) |
| 304 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- (For Highbay LED Fixtures) |
| 305 | Overall size 2.5sq.mm (50/0.25mm), 3Core |
| 306 | MAIN VERTICAL DISTRIBUTION SYSTEM: |
| 307 | Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCB's as incomer and outgoings SP/TP miniature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:- |
| 308 | TP&N Double Door Vertical DB's 4 way each (With provision of FP MCCB upto 125amp.) |
| 309 | MCCB's (MOULDED CASE CIRCUIT BREAKER):Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- |
| 310 | MCCB Four Pole 63amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 311 | MINIATURE CIRCUIT BREAKERS:Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 312 | MCB Triple Pole 40amp. (10kA, Curve-C) |
| 313 | SUB DISTRIBUTION SYSTEM: |
| 314 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB's:Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- |
| 315 | TP&N Vertical Double Door Distribution Board 4 way each. |
| 316 | Supply and erection of sheet metal Cable End Box (Make is same as MCB Distribution Board) mounting on the top or bottom of the MCB Distribution Board (Either Horizontal or Vertical) to keep loose wires & cables as per PWD General specifications including petty materials etc as required:- |
| 317 | Cable End Box for TPN Vertical 4/8/12Way |
| 318 | MINIATURE CIRCUIT BREAKERS:Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 319 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 320 | MCB Four Pole 40amp. (10kA, Curve-C) |
| 321 | MCB Four Pole 63amp. (10kA, Curve-C) |
| 322 | Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:- |
| 323 | PVC flexible pipe 40mm dia. |
| 324 | Supply and erection of Compression glands, Locking arrangement, Checknuts for PVC flexible pipe complete with as required:- |
| 325 | PVC compression Socket gland 40mm dia. |
| 326 | INDOOR LT PANELS: |
| 327 | LT PANELS & MCCB's (MOULDED CASE CIRCUIT BREAKERS):Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacturer should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP 54/55).Fabrication: Panel shall be made from 14/16 SWG CRCA sheet, conforming to IS 8623/1977-82. The sheet metal used for the fabrication of control panel will be 2mm for load bearing member’s door and fittings plates etc. the partitions and other non load bearing members will be fabricated out of 1.6mm sheet, the sheet will be of mild steel CRCA type. The base channel will be made out of 75 x 40 x 5mm rolled channel. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/top with cable glands etc. The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site. it should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar chamber as well as the cable chamber should be totally isolated from the feeder chamber. Where there crossing of the wire or bus links. It should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition.Painting: The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work . |
| 328 | Busbars: The panel shall be provided with TPN aluminium busbar of suitable size according to the size of MCCB's. Busbar shall be of high conductivity (53% to 58%) E91-E Grade aluminium (1A/Sq.mm). All Busbar will be air insulated with codified in Red, Yellow, Blue & Black as per standard for cable termination with the help of extended busbar only with proper adjustable cable supports. The main busbar would be supported upon non-hygroscopic SMC/DMC supports. Metering: The panel shall be completed with digital metering unit (with selector switches, voltmeter & ammeter) epoxy insulator, gasket, PVC sleeves, CT's & L.E.D. type indicator etc. Manufacturer of Panel should be CPRI Approved (Approval not older then 5 years) & ISO certified (Manufacturer workshop as per ISO 9001: 2015 standard) The Concerned contractor shall be approved the detailed drawing of panel with complete specification from the Engineer in charge at site.Detail of capacities of MCCB's to be installed in the cubical panel Enclosure (Excluding the cost of MCCB's) as per following:- |
| 329 | MAIN LT PANEL: |
| 330 | LT Panel enclosure having space for 1No. Incomer MCCB 200Amp. and 4Nos. outgoing MCCB's 40amp. to 100amp. according to the requirement at site (Approx. size 1825 x 1000 x 300mm)(DETAIL SEE IN PANEL INVENTORY) |
| 331 | MCCB's (MOULDED CASE CIRCUIT BREAKER):Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc |
| 332 | MCCB Four Pole 100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 333 | MCCB Four Pole 200amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 334 | MINIATURE CIRCUIT BREAKERS:Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 335 | MCB Four Pole 40amp. (10kA, Curve-C) |
| 336 | MCB Four Pole 63amp. (10kA, Curve-C) |
| 337 | ON LOAD CHANGEOVER SWITCH (With Sheet Enclosure): |
| 338 | Supply and erection of On Load Change over Switch with advance neutral UNIT in sheet enclosure on the existing surface. (Confirms to IS 13947 (Part-3). complete with G.I. Bolts, Nuts etc. according to the size of holes in the body of the enclosure & Connections on both sides of switch with suitable size of thimbles as per PWD General Specifications:- |
| 339 | On Load Change Over Switch Four Pole 200amp., 415volts |
| 340 | EARTHING SYSTEM (INDOOR): |
| 341 | COPPER EARTHING 8SWG :- Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 342 | Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long |
| 343 | Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:- |
| 344 | Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed) |
| 345 | COPPER EARTHING :-(Upto 14 metre in Length):-Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 346 | Earthing with 20mm x 3mm Copper Tape (upto 14Metre in Length) |
| 347 | COPPER EARTHING STRIP (As Additional Length):Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc.:- |
| 348 | Additional Length 20mm x 3mm thick Copper Tape . |
| 349 | INDOOR LT CABLES, CABLE TRAY, DWC PIPE , BRASS GLANDS & THIMBLES: |
| 350 | XLPE INSULATED UN-ARMOURED CABLES (LOOSE):-Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 351 | Overall size 6sq.mm (2Core) Un-armoured (Loose) |
| 352 | Overall size 16sq.mm (4 Core) Un-armoured (Loose) |
| 353 | Overall size 35sq.mm (3½ Core) Un-armoured (Loose) |
| 354 | Overall size 70sq.mm (3½ Core) Un-armoured (Loose) |
| 355 | Overall size 95sq.mm (3½ Core) Un-armoured (Loose) |
| 356 | CABLE TRAY:Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:- |
| 357 | Cable Tray Size 300mm x 50mm x 50mm (2mm thick) |
| 358 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1/2mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 359 | Double walled corrugated (DWC) HDPE pipe 63/51 mm (outer/ inner dia.) |
| 360 | Double Walled Corrugated HDPE Pipe 90/76mm (Outer/ Inner dia.) |
| 361 | Double walled corrugated (DWC) HDPE pipe120/103.50mm (outer/ inner dia.) |
| 362 | Double Walled Corrugated HDPE Pipe 160/ 136mm (Outer/ Inner dia.) |
| 363 | Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections:- |
| 364 | Brass Gland for Aluminium cable 2/3/4 Core size 6sq.mm |
| 365 | Brass Gland for Aluminium cable 2/3/4 Core size 16sq.mm |
| 366 | Brass Gland for Aluminium cable 2/3/3½/4 Core size 25-35sq.mm |
| 367 | Brass Gland for Aluminium cable 2/3/3½/4 Core size 70sq.mm |
| 368 | Brass Gland for Aluminium cable 3/3½/4 Core size 95-120sq.mm |
| 369 | Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:- |
| 370 | Aluminium thimble cable Core size 4 - 6sq.mm |
| 371 | Aluminium thimble cable Core size 10 -16sq.mm |
| 372 | Aluminium thimble cable Core size 25 -35sq.mm |
| 373 | Aluminium thimble cable Core size 70sq.mm |
| 374 | Aluminium thimble cable Core size 95sq.mm |
| 375 | Supply and erection of heavy duty Copper thimbles/lugs for cable end termination duly crimped including making necessary connections etc. completely:- |
| 376 | Copper thimble cable Core size 4 - 6sq.mm |
| 377 | Copper thimble cable Core size 10 - 16sq.mm |
| 378 | SAFETY EQUIPMENTS: |
| 379 | Providing and fixing of 4.5 Kg. Capacity FIRE EXTINGUISHER,CO2 type as per IS:15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect |
| 380 | Providing 1No. 13 Passenger Lifts, 2Stops: |
| 381 | Supply, installation, testing and commissioning of 1 No. lift of 13 passengers machine room less.Type and Capacity : Approximately 884 Kg, 13 Passengers Speed:1.0 Meter per second Type of drive: AC Variable Voltage Variable Frequency with 16-Bit Microprocessor. Motor: Permanent Magnet Gearless Machine to be hoisted on the top of guide rail within the elevator hoist way Travel: Approximately 5 meter________ Serving: _2 Floors _2Stops _ 2Openings _2Levels (All on the same side) Hoist way Required: 2050mm (Wide) x 2500mm (Deep) Clear dimensions Headroom Height (HR): 5000 mm beyond finished floor level of last landing Pit Depth: 1600mm below the finish floor level of first landing Car Size Area: Minimum 2.06 square meter and Maximum 2.20 square meter Hairline Finish.Car Entrance: Center Opening Automatic Doors with AVCF Drive (all landing doors must be fire-rated for a minimum of 120 minutes) of Stainless steel with Honey comb /Hairline Finish with a clear opening of 900mm/1000mm (wide) x 2000mm/2100 mm (high) Door operation: Automatic DC Door operation with adjustable door opening and closing timings Control: Simplex full selective collective control with and without attentdent Operation: Automatic Power Supply: 415 Volts, 3- phase, 50Hz Alternating Current Flooring: Floor Skid - Resistant as per standard Fan: Blower Fan in Car for ventilation with Auto cut off Lighting: LED for Car Lighting Indicators: LED Dot matrix / Digital 3 segement direction and position indicators in the car and at all landings Hand Rail: Stainless Steel round Hand rail not less than 600mm long at 900mm above floor level (Side LH,Side RH & Rear) Call Button Height: Call button (Outside the lift) placed at a height between 800mm-1meter from the floor level Control Panel Height: Control panel placed at a height between 800mm-1meter from the floor level Std. Govt. features. |
| 382 | Other Features: 1. Battery operated emergency light with rechargeable battery 2. Battery operated emergency alarm with rechargeable battery 3. Adjustable Guide shoes 4. Micro movement LED based buttons 5. Door Open and Close buttons 6. Emergency Intercom provided inside the elevator 7. Emergency Intercom usable without the voice communication 8. Load weighing device with overload bypass feature and Overload function with Audio Visual Indication 9. Steel items, door frames sill angle's, fascia plates, spring buffers10. Automatic phase reversal device and Phase Failure protection11. Call registration 12. Audio & Video System installted in the lift indicating arrival at a floor 13. Manual Rescue System14. Additional car gate lock 15. Automatic break testing infrared safety curten 16. Braille Buttons (Inside and outside) with Braille instructions for the communication system 17. Kick plate/Skirting 18. Lift anoucement system to announce floor level's in english language only and indication of door for entrance / exit is either Open or Close 19. Car Operating Panel 20. Car plateform constructed out of cold rolled grain oreinted formed sheets of steel 21. Phase two device fire man drive 22. Fire Man switch at main lobby 23. Car false ceiling in stainless steel 24. Pit ladder 25. Anti Nuisance car call protection 26. Door Nudging 27. Automated Resuce Device to bring the elevator to the nearest landing in case of power failure.28. The use of visually and accoustically reflective wall surace should be minimized within the lift car as visual reflections can cause discomfort and affect the visual acuity of people with impairements.29. The floor of lift car should be slip resistant and have similar frictional qualities to thye floor of lift landing to decrease the risk of stumbling.30. The provision of mirror on the wall of the lift car opposite the lift door not extend below 900mm from the lift floor to avoid confusing people with impaired sight.31. The emergency communication system should be coupled with an induction loop system installed all around the lift. Telephone units, where provided, should have an inbuilt inductive coupler to assist persons using hearing aids. |
| 383 | XLPE INSULATED UN-ARMOURED CABLES (LOOSE):-Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 384 | Overall size 16sq.mm (4Core) Un-armoured (Loose) |
| 385 | XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE):Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- |
| 386 | Overall size 16sq.mm (4Core) Un-armoured (On-Surface) |
| 387 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 388 | Double walled corrugated (DWC) HDPE pipe 63/51 mm (outer/ inner dia.) |
| 389 | COPPER EARTHING (8 SWG COPPER EARTHING): Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 390 | Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long |
| 391 | Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (On Surface) |
| 392 | MCCB's (MOULDED CASE CIRCUIT BREAKER):Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubicle type) in the existing Cubical Panel (conforms to IEC:60947-II) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD General Specifications (Electrical Works) complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with sutiable size of Thimbles etc. |
| 393 | MCCB Four Pole 40amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 394 | MS SHEET ENCLOSURE FOR MCCB's:Supply & Erection of indoor type MCCB enclosure of suitable size having provision for MCCB with extended rotary handle. The Enclosure shall be made from 14/16 SWG CRCA sheet, confirming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/top with cable glands etc. The sheet metal is sprayed with corrosion resistant etch primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:- |
| 395 | MS Sheet Enclosure having provision for MCCB 40-160Amp.with extended rotary handle (Approx. Size 500mm x 300mm x 200mm) |
| 396 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB's:Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- |
| 397 | SP&N Double Door Distribution Board 8 way each |
| 398 | Supply and erection of sheet metal Cable End Box (Make is same as MCB Distribution Board) mounting on the top or bottom of the MCB Distribution Board (Either Horizontal or Vertical) to keep loose wires & cables as per PWD General specifications including petty materials etc as required:- |
| 399 | Cable End Box for SPN 8 Way |
| 400 | MINIATURE CIRCUIT BREAKERS:Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- |
| 401 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 402 | MCB Double Pole 6-32amp. (10kA, Curve-C) |
| 403 | Providing CCTV System: |
| 404 | Supply, erection, testing & commissioning of 5MP IP Network TDN Low-Light IR Rugged Dome Camera, 1/2.8\\" CMOS or better, 5MP (2592 x 1944), Max Frame Rate: 50fps or better, Quad stream at various resolution & Frame Rates, Min. Illumination required 0.005 lux @ F1.6 (color), 0 Lux IR On, Smart IR with upto 40m IR distance or better, Auto ICR (Infrared Cut Filter) 130dB True WDR, S/N Ratio 55db, Shutter Speed 1/3 - 1/100,000s; Adavance Video Compression technology such as H.265 & H.264 High Profile & MJPEG ,Streams: 4, Video Streams configurable at different Resolutions and FPS Max@50FPS , 2.8 mm, Fixed, F1.4,Electronic Image Stabilization with G- Sensor, BLC, HLC, 3DNR White Balance, Minimum Edge Intelligence, Protocols: IPv4, IPv6, TCP/IP, HTTP, HTTPS, RTSP/RTP/RTCP, IGMP/Multicast, SMTP, SNMP, DHCP, NTP, DNS, DDNS, CoS, QoS, 802.1X, UPnP, mDNS(Bonjour), UDP, ICMP, ARP, TLS, SFTP Video Analytics : Motion Detection, Scene Change, Tamper Detection, Smart Motion, Intrusion, Loitering, Line Crossing Detection, Unattended Object Detection, Missing Object Detection, People Counter, Queuing, Crowd Gathering, Heat Map, Face Detection, camera reset option in camera, 5 Privacy Mask, 6 Region Of Intreset, Defog, TLS 1.2 & 1.3, AES-128/256, SSH/Telnet closed, Stream Encryption, Secure boot, Prevent brute-force attack, 2TB Micro SD/SDHC/SDXC card slot; Gore Vent, PoE (802.3 af) and 12V DC, Max 10.6 W or better, IP 66 & IP67, IK 10 vandal proof with Aluminium + Polycarbonate Housing, Having Operating temp range :-30°C ~ 60°C. Certifications: ONVIF Profile S,G,T,M compliant (Can be verified from onvif Website, T profile must have secure streaming), UL, FCC, CE, RoHS, BIS-ER, STQC Complied & NDAA Section 889 compliant. complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 405 | Supply, erection, testing & commissioning of 5MP IP Network TDN Low-Light IR Rugged Bullet Camera, 1/2.8\\" CMOS or better, 5MP (2592 x 1944), Max Frame Rate: 50fps or better, Quad stream at various resolution & Frame Rates, Min. Illumination required 0.005 lux @ F1.6 (color), 0 Lux IR On, Smart IR with upto 50m IR distance or better, Auto ICR (Infrared Cut Filter) 130dB True WDR, S/N Ratio 55db, Shutter Speed 1/3 - 1/100,000s; Adavance Video Compression technology such as H.265 & H.264 High Profile & MJPEG ,Streams: 4, Video Streams configurable at different Resolutions and FPS Max@50FPS , 3.6 mm, Fixed, F1.4,Electronic Image Stabilization with G- Sensor, BLC, HLC, 3DNR White Balance, Minimum Edge Intelligence, Protocols: IPv4, IPv6, TCP/IP, HTTP, HTTPS, RTSP/RTP/RTCP, IGMP/Multicast, SMTP, SNMP, DHCP, NTP, DNS, DDNS, CoS, QoS, 802.1X, UPnP, mDNS(Bonjour), UDP, ICMP, ARP, TLS, SFTP Video Analytics : Motion Detection, Scene Change, Tamper Detection, Smart Motion, Intrusion, Loitering, Line Crossing Detection, Unattended Object Detection, Missing Object Detection, People Counter, Queuing, Crowd Gathering, Heat Map, Face Detection, camera reset option in camera, 5 Privacy Mask, 6 Region Of Intreset, Defog, TLS 1.2 & 1.3, AES-128/256, SSH/Telnet closed, Stream Encryption, Secure boot, Prevent brute-force attack, 2TB Micro SD/SDHC/SDXC card slot; Gore Vent, PoE (802.3 af) and 12V DC, Max 10.6 W or better, IP 66 & IP67, IK 10 vandal proof with Aluminium + Polycarbonate Housing, Having Operating temp range :-30°C ~ 60°C. Certifications: ONVIF Profile S,G,T,M compliant (Can be verified from onvif Website, T profile must have secure streaming), UL, FCC, CE, RoHS, BIS-ER, STQC Complied & NDAA Section 889 compliant. complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 406 | Supply, erection, testing & commissioning of 32 Channel Linux based Recording server (Network Video Recorder shall be support the STQC Cameras), 4 SATA interface, Up to 32 channel Video Inputs, Servershall have throughput of incoming bandwidth 512Mbps & outgoing 512Mbps, 2* HDMI , 1 *VGA Video output. Supports live view, storage, and playback at 1- 8MP resolution,Shall be capable of live streaming & Storing 32 cameras, Shall support Net HDD, Storage up to 8 TB Surveillance HDD,Shall support audio, G.711A/G.711U, Shall support 1 E-sata port, 2x RJ45 10M/100M/1000M ports,Audio input 1 channel, Audio Output 1 channel output , Alarm input 16 channel, Alarm Output 1 channel output, USB2.0*1, USB3.0*1+USB2.0*1 port , RS485*1,Protocol :IPv4, IPv6, TCP/IP, HTTP, HTTPS, DDNS,RTMP, SMTP(SSL), SNMP, DHCP, PPPoE, UPnP,NTP, P2P, FTP , Simultaneously record multiple streams in any combination of H.264/H.265/H.264+/H.265+, support Start, stop, normal play, back play, frame by frame forward, full screen, Fast forward / backward (2x, 4x, 8x,16x), Slow forward (1/2x, 1/4x, 1/8x,1/16x), Add custom/ Default Tag for any events at the time of playback, digital zoom, video clip, sub stream/main-stream, playback video bar, Shall be able to take actions pre and post recording, Send email, show message, send email, FTP upload video or screenshot, Cloud upload video or screenshot, full screen, voice prompts, Alarm output trigger, PTZ linkage on events, support the display of VCA metadata on video live-view and and playback, Supports AI from camera side : Face Detection, Human Detection, Vehicle Detection, Perimeter Intrusion Detection, Line Crossing Detection, Cross Counting, Heat Map, Crowd Density Detection, Queue Length Detection, License Plate Detection, Rare Sound Detection, Stationary Object Detection, Sound Detection, Capable to show statistics and graphs of events for different interval of time search, Shall support S.M.A.R.T HDD function for HDD status,Onvif Support , Power Supply : DC12V/2A ,Consumption without HDD : 12W , Temperature : -10°C~+50°C (14°F ~ 122°F) Humidity : Less than 90%RH , 378*326*66mm (W×D×H) Dimensions ,Certificates:CE, BIS, FCC, ROHS and REACH. complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 407 | Supply, erection, testing & commissioning of Switches: 24 Ports 10/100/1000 Mbps PoE + 4 Ports 10G SFP+ Smart Managed Layer 2 Switch, Power budget 370W from day1, Support 802.3af/at), Switching Capacity 128 Gbps, MAC Address Table 16K, Packet Forwarding Rate, 95.24 Mpps, Flash Memory 64 MB, DRAM Size 256 MB DDR3, IGMP v1/v2/v3 Snooping & MLD snooping v1/v2, 802.3x Flow Control, HOL Blocking Prevention, LLDP/ LLDP-MED, 802.1D, 802.1W, 802.1s, 802.1Q, 802.1p QOS, SPQ, WRR, WDRR, Bandwidth Control, Static routing, IPv6 Neighbor Discovery (ND), ACL Max. 768 rules shared by IPv4, MAC, & IPv6, Traffic segmentation, ARP Spoofing Prevention, ARP Inspection, DHCP Snooping, MAC authentication, SSH v2, TLS v.1.2, DoS attack prevention, 802.1X Port-based Access Control, Port Security, RADIUS/TACACS+, MD5 authentication, GUI, Full CLI, Telnet Server, TFTP Client, MDI/MDIX, SNMP v1/v2c/v3. Internal/External 6 kV surge protection on all RJ-45 access ports, Operating Temperature -5 to 50°C, Storage Temperature -20 to 70°C, Operating Humidity 0% to 95% relative humidity, Certifiate: EMC EN 55032, Class A; EN 61000-3-2; EN 61000-3-3; EN 55024, Safety EN 62368-1, ROHS EN IEC 63000, 47 CFR FCC part 15: 2017, Subpart V, Class A, ICES-003, IEC 62368-1, IEC 60950-1, IEC 60950-1/AMD1, IEC 60950-1/AMD2, UL 62368-1 & CAN/CSA C22.2 No. 62368-1-14. MTCTE/TEC-ER (as notified vide Indian Telegraph (Amendment) Rules, 2017, OEM Should be ISO 45001, ISO 27001 & ISO 14001 Certified, OEM Should have Certificate for Industrial Cyber Security Capability (Like - IEC-62443-4-1:2018 or Equivalent) complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 408 | Supply, erection, testing & commissioning of HDD Formatted capacity 6 TB, Data transfer rate (max) Buffer to host Host to/from drive (sustained) 6 Gb/s 171 MB/s, Cache (MB) 64, Rotational speed (RPM) IntelliPower, Load/unload cycles4 300,000, Non-recoverable read errors per bits read <1 in 1014,Operating (2 ms, read/write) 30,Operating (2 ms, read) 65, Non-operating (2 ms) 250,Average power requirements (W) Read/Write 5.90, Idle 4.90, Standby and Sleep 0.40 complete in all respects as approved and desired by the Engineer in-charge at site. |
| 409 | Supply, erection, testing & commissioning of Display : 50 inch, 4K (3,840 x 2,160), Direct LED, Professional Display with 4K Processor, Native Contrast ratio 5,000:1 or higher, Response time 12 ms or lower, Brightness 400 cd/m² or higher, 24/7, Portrait/Tilt functionality, HDMI Auto wake up, HTML5 platform, 16GB On Board Storage, HDMI*4 with HDCP 2.3 / RS232 / USB / RJ45 / Wi-Fi Direct / 20W Speakers / Android OS or similar, Viewing angle 178 degree, Apple AirPlay & Chromecast. complete in all respects as approved and desired by the Engineer-in-charge at site. |
| 410 | Supply, Installation, Testing & Commissioning of 6 Mtr HDMI Cable for NVR, UL Listed complete in all respects as approved and desired by the Engineer in-charge at site. |
| 411 | Supply, Installation, Testing and Commissioning of Wall Mount 15U x 600 W x 600 D ,Front Glass Door (tinted,Toughened) with Lock & Key, 2 pairs of 19\\" Mounting Rails with U-Marking , Welded Side Walls, Min Accessories : 1U Cable Manager (1), Hardware Packet (1 Pkt), 6 Socket 5 Amp. Power Distribution Unit (1 No), Roof Mounted Fan Unit / 90 CFM /230V AC.as per DIN 41494 Standards complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 412 | Supply, Installation, Testing & Commissioning of 1000VA LIT UPS/ Power Plant with SMF batteries having 30 Minutes backup time, Cold Start, 3 No. plug Indian style, Automatic Voltage Controller, Overload protection, Over charging Protection, 2 No. 12v 7Ah Batteries, Wide Input Range, Fan Less Cooling system, Transfer time less than 8ms,Audible Alarm etc. complete in all respects as approved and desired by the Engineer in-charge at site. |
| 413 | COPPER CONDUCTOR CABLES FOR SPECIAL ELECTRICAL SERVICES:Supply and erection of CAT 6 with 23AWG solid bare copper conductor, special grade PE insulation with star separator, 4pair Unshielded Twisted Pair (UTP) industrial cable, FR PVC sheathed, Class-E, 250 MHz of bandwidth, supporting data transfer speeds of up to 10 Gbps (10GBASE-T) for distances up to approximately 180 feet, cables are manufactured and tested to meet the ANSI/TIA 568-C.2 and ISO/IEC 11801 Class E standards left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 414 | CAT 6 LAN cable |
| 415 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 416 | Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed |
| 417 | Providing Fire Detection & Alarming System: |
| 418 | FIRE PANELS & ANNUNCIATORS: |
| 419 | Supply, installation, testing & Commissioning of 1 loop Microprocessor based Multi-loop, Networkable Addressable Fire Alarm Control Panel with minimum 10 inch 1024x600 resolution LCD with touch capability, including audible and visible feedback, backlit by along life, solid-state LCD. It shall also include a full QWERTY-style keypad on the color, touch screen display. The display shall have the ability to scroll events by type (i.e.Fire Alarm, Supervisory Alarm, Trouble, etc) using the touch screen with customizable buttons ,10000 history events & autolearn feature for programming. The system can be supported upto 2000 generation zone & 2000 logic zone & 50 releasing zone. The panels in network having true peer to peer provision. The panel shall have provision to support upto 50 releasing zones to protect against 50 independent hazards. The panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable upto 10Loops. Each loop shall have a capacity of minimum 150 detectors & 150 other devices excluding 20%spare. The panel shall work in degrade mode in case of CPU failure, Products not having this feature may offer Redundant CPU. Four access levels, flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30mins in alarm condition with the charging capacity of 210 AH. The panel shall be capable of auto learn programing feature without any dependency ondongleor programming software. The system should be UL FM approved complete in all respects as approved and desired by the Engineer in-charge at site. |
| 420 | Supply, installation, testing & Commissioning of Beam Detector. The beam detector shall be used for High Ceiling application with a detection range upto 100 mtrs having 4 manual & 2 auto sensitivity settings. The beam detector shall be True addressable installed on the SLC circuite & communicate directly with the panel without any interface module. UL and FM Approved. Addressing shall be with user friendly rotary decimal switches complete in all respects as approved and desired by the Engineer in-charge at site. complete in all respects as approved and desired by the Engineer in-charge at site. |
| 421 | Supply, installation, testing & Commissioning of Addressable photo-Thermal multi criteria Detector inbuilt isolator and base with sensitivity range as per NFPA 72. The intelligent detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. It shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. The detector shall have bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary/ Electronic decimal switches. Designed to meet UL & FM Approved . The solution should be from single OEM.. complete in all respects as approved and desired by the Engineer in-charge at site. |
| 422 | Supply, installation, testing & Commissioning of Addressable Rate of Rise Heat Detector rated at 8.3 deg C/min.NFPA 72. The detector shall have bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary/ Electronic decimal switches.UL & FM Approved The solution should be from single OEM complete in all respects as approved and desired by the Engineer in-charge at site. |
| 423 | Supply, installation, testing & Commissioning of Addressable Manual Call Point (Pull down / Break Glass Type). The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device complete in all respects as approved and desired by the Engineer in-charge at site.UL & FM Approved . complete in all respects as approved and desired by the Engineer in-charge at site. |
| 424 | Supply, installation, testing & Commissioning of Sounder cum Strobe rated at 80 dBA @ 3m for Audible annunciation and Min.110 cd flashintg at 1 Hz for visual indication. UL & FM Approved complete in all respects as approved and desired by the Engineer in-charge at site. |
| 425 | Supply, installation, testing & Commissioning of Addressable Control Module for Sounders / Strobes / Sounder cum Strobes/ Telephone Jack. The control module shall provide supervised NAC output rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary / Electronic decimal switches UL & FM Approved complete in all respects as approved and desired by the Engineer in-charge at site. |
| 426 | Supply, installation, testing & Commissioning of Isolator Module for Isolating short / dewired / loose circuits with automatic resetting arrangement. Isolator Base can also be proposed, however in that case needs to be considered with each detector & module. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device.UL & FM Approved Module shall be supplied with mounting plate from OEM for ease of installation & maintenance.The solution should be from single OEM.. complete in all respects as approved and desired by the Engineer in-charge at site. |
| 427 | Supply, installation, testing & Commissioning of Exit LED M ST LED LED based exit sign with dimming function, Reading distance, exit sign Two-sided 25m, Voltage 220-240VAC / 50-60Hz, Power consumption 3.3W / 3.5VA, Battery 3.6V/1.2Ah NiMH, Battery protection Over charge protection /deep discharge protection, Charging Time 16 hours, Battery back-up time 1 hour / 3 hours / 8 hours (from dip switch), Light source 15 LED, Approvals EN 60598-1, EN 60598-2-22, EN 55015, EN 61547, EN 61000-3-2, EN 61000-3-3, Ambient temperature 5 to 40 °C, Humidity Up to 95%, IK rating IK09, IP rating IP40, Dimensions 265 x 53 x 222 mm, Weight 540 / 742 gr , Colour Anodized aluminum / black plastic, Materials Aluminum, Acrylic Plate, Mounting method Ceiling, wall bracket, suspended, pendulum, flag mount, Delivered as self-contained/auto test luminaire Choice of 1, 3 or 8 hour autonomy via DIP switch IP 40 – dustproof luminaire Reading distance upto 25 meters.High lumen output – 1h = 180lm / 3h = 110lm /8h = 40lm Technical lifetime of LED > 100 000 hours , 4 Pictograms (left, right, down, up) are included in the luminaire ordering part code complete in all respects as approved and desired by the Engineer in-charge at site. |
| 428 | Supply, installation, testing & Commissioning of Online UPS 1 kva 800 Watts Tower UPS with 1 hour battery backup. Operating Temperature Range 0 to 40 Degree @ 100% Load @ 50 Degree with 50% Load,Storage Temperature -15°C~60°C, Relative Humidity 0-95% No condensates, Acoustic Noise 40 dBA @ 1 Meter, Cooling Forced air cooling by the internal fans, Input Socket IEC C13, Output Socket IEC C14, No of output sockets 3 No's, Rated Input Voltage 208/220/230/240 Vac, Maximum working input voltage range 160 to 300 Vac @ 100% Load, 100 to 300 Vac @ 50% Load, Input Power Factor 0.99, Input THDi% 5%, Generator Set Yes 1.5 x UPS Capacity, Rated kVA 1000 VA, Rated kW 800 Watts, Load type Resistive load/ lagging load/ non-linear load/ transformer load/ lighting load, Load power factor range 0.5~1 lagging, Load Crest Ratio 3:1, Online Efficiency 88%, Rated Battery Voltage 36 Vdc, Battery Type VRLA (Valve Regulated Lead Acid Battery), 12VDC, Battery backup Back UP : 936VAH, Maximum charging current 10 Amps, ECO Mode Available, Communication (Independent SCI) Available, Intelligent Card slot (Independent SCI) Available, OVCD Available, EPO Function Available, Intelligent Fans Speed control Available, Auto restart function Available, Cold start Available complete in all respects as approved and desired by the Engineer in-charge at site.. complete in all respects as approved and desired by the Engineer in-charge at site. |
| 429 | Supply and erection of fire survival cable for fire alarm & PA system with annealed stranded copper conductor, fire resistant mica tape wrapped (at 950°C for 180 minutes), XLPE insulated, LSHZ (low smoke & zero halogen) bedding, LSZH (low smoke & zero halogen) red outer sheath, galvanized steel wire armour, 600/1000 volts grade, Fire resistant to IEC 331 & BS7846 F2/BS6387 & CWZ, Acid gas emission to BS EN 50267 (IEC60754), smoke emission to BS EN 50268 (IEC61034) and flame propagation to BS EN 50265, BS EN 50266 (IEC 60332-3) left bare in pipe or casing or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 430 | Fire Survival cable 2Coe x 1.5 sq.mm |
| 431 | HEAVY GUAGE WELDED CONDUIT PIPES:Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- |
| 432 | Heavy gauge welded conduit pipe 25mm dia. (ISI marked 1.60mm thick) Flushed |
| 433 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 434 | Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed |
| 435 | Providing Interactive Display Panel & Public Addressable System: |
| 436 | Supply, installation, testing & Commissioning of Desktop Microphone High quality, professional microphone Flexible goose neck ON/OFF switch XLR connector, Capsule Type Condenser, two capsules Polar Pattern Uni-direction, Frequency Response 100-7500Hz, Sensitivity -29+/-dB, Impedance 150ohm(unbalance), Cable 10M, Power Requirements 3V DC/48V phantom power complete in all respects as approved and desired by the Engineer in-charge at site. |
| 437 | Supply,installation, testing & Commissioning of wireless collor mic as per site requirement complete in all respects as approved and desired by the Engineer in-charge at site. |
| 438 | Supply, installation, testing & Commissioning of 260 W Highly flexible mixer amplifier is designed for a wide variety of voice and background music applications, 100v&4-16 OHMS Transformer- Less Design, Super Class-D Topology Full Band with PWM Modulator Ultra-Low Distortion, 20 Hz- 20 kHz (+0/-0.25 dB (80 load, 3 dB below rated power, SM PS RMS Power Limit 290 Watts, Media Player MP3 (USB) /FM/ Bluetooth , Signal input/ Output Balanced Line in - Line Outl 100 V signal input , Bass & Treble control +/- 10 dB , Mic/ Line input Phoenix connector for 2 mies I RCA stereo Input for AUX Line input Sensitivity 4mV(mic) I 300 mV (Line) Impedance > 1 Kn (mic) 15 Kn (Line) Signal To Noise-Ratio 119 dB(A) Dynamic range 119 dB(A) Power Output 250 watts I 100 Volt speak er output - Phoenix connector Damping factor@ 8 Ohm 350 , Short circuit protection, DC protection, under voltage protection, temperature protection, overload protection Operating Temperature & Humidity -10°c to 50°c@ 90% relative humidity (non condensing) Cooling Natural dissipation through heat sink and temperature-controlled fan Safety Standards Complaint to IEC/EN 60065:2001 (7th E) + Al:2005 • A2:2010 Complaint to lEC/EN/UL 62368-1: 2014 (2\\"d E) Complaint to EN 60065.2002 + A12006 + All: 2008 + A2:2010 + A12:2011 Complaint to EN 62368:2014 Complaint to CSA C22.2 0.62368-1-14:2014 Complaint to UL 62368:2014 complete in all respects as approved and desired by the Engineer in-charge at site. |
| 439 | Supply, installation, testing & Commissioning of 6W Ceiling Speaker with max SPL1M/6W 95dB . Frequency response of 80Hz-20KHz The speaker should have tappings at 6W/3W/1.5W with 4 pole screw connector as complete in all respects as approved and desired by the Engineer in-charge at site. .. complete in all respects as approved and desired by the Engineer in-charge at site. |
| 440 | Supply, installation, testing & Commissioning of CE Complied 12W wall mount speaker with following specifications:- Frequency response 110 Hz - 14 kHz, SPL @ 1W/1M-92dB, with 100 V input. complete in all respects as approved and desired by the Engineer in-charge at site. |
| 441 | Supply, Installation, Testing & Commissioning of 2 core 1.5 sqmm shielded cable for speaker Project specific OEM authorization required for executing agency. complete in all respect as per satisfaction of the Engineer in charge of the work. |
| 442 | Supply, Installation, Testing & Commissioning of Interactive display 75” or higher, UHD 3840 × 2160 pixels or Higher, Brightness (typical) 400 nits or Higher, Contrast ratio (typical) 1200:1 or Higher, Response time 8 ms or Better, Light life (typical) 50,000 hrs or Higher, 8H Hardness with 3.2T Thickness, Anti-glare coating, Infrared touch, 20 touch points or Higher, Touch response time < 5 ms or Better, CPU Quad core or Better, Memory 8GB DDR3 or Higher, Storage 64GB or Higher , OS Android 14.0 with EDLA Certificate, 3 x HDMI, , 1 x Stereo Mini Jack, 1x PC Audio In, 1 x Slot-in PC (OPS) or Higher, 2 x USB 3.0 Type A, 2 x USB Type C, 1 x USB Type B (touch) or Higher, 1x RS232 In, 1 x RJ45, Stereo Sound with in-built 15 Watt x 2 speakers, inbuilt magnetic pen holder with up to two pens, control buttons on Interactive display like Volume UP/Down, Home, Back, Menu, Touch on/off & Power Buttons for ease in teaching. in built tool to allow participants to submit answers from their Smart Phones (Answering/Voting/Messaging), inbuilt Dual band Wi-fi (2.4 & 5Ghz), inbuilt Bluetooth version 5.0 or latest, inbuilt whiteboard software for teaching/ training using Interactive display with features like (Pen, thickness of pen, colours of pen, Pixels eraser and Region eraser, Shapes (Circle, Triangle, Rectangle, arrows),Background of White board (multiple colours also use picture, shape),Redo/Undo, Next/Previous, Select & Drag option, Switching between single touch and multiple touch, Clear screen, List of pages with deleting option, Switching tool bar right to left, Many other Tools (Compass, Protector, Insert Table, Curtain, Timer, Spotlight, Multiscreen (divide board in 2,3,and 4 parts with background colour and different pen colour), on screen annotation. Interactive display should allow user to share/mirror the content of Laptop/Desktop and mobile device (Android) wirelessly and Screen Share software to show up to 4 Multiple screen at same time. Floating Tool, Built in Google Play store , YouTube inbuild cloud drive access from Google drive & one drive. gesture control like Hold five fingers on screen for Interactive display sleep mode, hold and move three fingers on screen for Floating menu & swipe the screen Upside for Pull up menu control. split screen user should be able to split the screen to operate multitask like play a video in half of screen and open whiteboard in other half side. USB sharing for Android, Internal PC or other External PC / Device. provision to lock all the USB port, Screen Lock, application lock to restrict unwanted access. Should have provision for Touch On/Off on front of Display. Should have inbuilt Volume equalizer and surround sound support to enhance the sound quality. Should have built in Screen recording feature supports up to full HD resolutions or better. Should have builtin screen shot option using single click. Power AC 100-240V 50/60Hz, Maximum Power Consumption 450 W or Better, Standby Power Consumption <0.5 W or Better, Operating temperature 0°C ~ 40°C or Better, Operating Humidity 10% ~ 80%, Certifications BIS,CE, FCC & RoHS . with Image device CMOS 1 CMOS 1/2.7”1080p30/25/50/60, 720 p30 /25/50/60, (up to 1080p30 on XT), Focal Length f3.5mm ~ 42.3mm, F1.8 ~ F2.8, Min Illumination 0.5 Lux @ (F1.8, AGC ON),HFoV 72°, VFoV 43°, Optical Zoom (), Digital Zoom (), 16x, Pan Range +/-170°, Tilt Range +/- 30° Serial Control, UVC via USB – Serial In-Out, Clients Supported Cloud Office (ACO), Workplace, Equinox, 3rd Party Clients Supported MS® Teams, MS® SfB, Skype®, Zoom®, Bluejeans®, Starleaf®, Pexip®, Cisco Webex®, Google Hangouts® ,Video Configurations White balance (auto/manual); Focus Mode (auto/manual); Sharpness; Backlight; Exposure Compensation; Picture (auto/manual) and WDR level, IR Repeater as TTL Signal, On pin 7 Serial In, Microphone Included 4 MEMS microphones: 100Hz to 7,000Hz - Pickup range: 20ft/6m, Audio expansion: daisy chain connection (future release). • Full Duplex • Acoustic Echo Cancellation and Noise Suppression Touch buttons: Answer call / Power - End Call , Bluetooth , Volume Up / Down,Mute • LED Status Indicators. Power statu, Call status, Bluetooth status,Battery status,Upgradable Software, Upgradable Software, Power Options, Integrated Lithium Polymer Battery complete in all respects as approved and desired by the Engineer in-charge at site. |
| 443 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 444 | Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed |
| 445 | Providing 1No. 58.5KVA Silent Diesel Generating Set: |
| 446 | Supply, Erection, Testing and Commissioning of Silent (Sound Proof) Diesel Generator Set 58.5 KVA /46.8KW with Manual Control Panel. It should be air cooled/water cooled naturally aspirated/ turbo charged/ turbo charged after cool (As per manufacturer standard).ENGINE: The Diesel engine developing 75.5 BHP (Approx.) for giving a power rating as per ISO 8528- Part-1 ( With CPCB-IV Norms as amended upto date) in KVA at the load terminals of alternator at 1500 rpm at actual site conditions. The engine shall confirm to IS 10000/ ISO 3046/ BS: 649/ BS 5514 amended up to date have dynamically balanced Fly wheel, air cleaner (dry/ oil bath type) as per manufacturer standard. A mechanical/ electronic governor of TYPE A1 AND A2 to maintain engine speed at all conditions of load, daily fuel service tank of minimum 8 hours running capacity as per manufacturer standard, Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noise level.suitable self-starter for 12 V/ 24 V DC ,battery charging alternator unit and voltage regulator, Lubrication oil cooler,Lubrication oil filters with replaceable elements.ENGINE CONTROL PANEL: Engine control panel fitted and having digital display i.e Start/stop key switch/push button, Battery charging indication,Engine Hours indications, Over speed indication, High water temperature indication, Lubricant oil pressure indication,) RPM indication and MCCB (Fixed Thermal and Adjustable Thermal protection) of suitable rating for outgoing supply. ALTERNATOR: The alternator should be designed as per (IS4722 and IEC:34 ) standard. Rated Power Factor : 0.8 (lag), Rated voltage : 230/415 volt, SPDP (Screen Protected Drip Proof), Degree of protection: IP-23, Ventilation : Self ventilated air cooled Alternator should have 40 degree maximum class H insulation, Automatic voltage regulator unit should be provided as per standard practice of manufacturer. Its voltage dip shall not exceed more than 20% of the rated voltage at any step load or transient load as per ISO 8528 (Part-1). Its efficiency at full load 0.8 power factor, 10% overload one hour in every 12 hrs of continuous use. |
| 447 | ACOUSTIC ENCLOSURE: The enclosure shall be fabricated out the CRCA sheet of thickness not less than 1.6 mm on the outside cover with inside cover having not less than 0.6 mm thick perforated powder coated CRCA sheet. It should be IP54 Suitable for outdoor installation exposed to weather conditions, noise level up to 75 dB (A). All sheet metal parts should be processed through 7-tank pre treatment process and batteries accommodated in the battery rack .The acoustic lining should be made up of high quality insulation material i.e. Rockwool / glass/ mineral wool / PU foam of appropriate thickness & density for sound absorption.The inside of enclosure should be provided with at least one no. 28 W-T5 fluorescent tube light/ LED 10Watt luminaries controlled by a 5A switch for adequate lighting during servicing etc.with 2 year warranty from the date of installation. complete in all respect as desired by engineer at site:-The Generator set should be instaaled at site on the suitable size existing plinth of RCC as per specifacation DG set as per satisfacation of the Engineer- in-Charge at site. The model of engine will be decided by the Engineer in Charge. MANUAL CONTROL PANEL: Manual control panel shall be fabricated out of 1.6 mm sheet steel, totally enclosed, dust, damp and vermin proof wall mounted/ free standing floor mounted type with IP-53 degree of protection & front operated, composite meter for digital display, HRC fuses of suitable rating. MCCB (Fixed Thermal and Adjustable Thermal protection)/ ACB (Over cuurent/ overload, shorcircuit, instantenous, earth fault protection) should be used. Battery charger complete with voltage regulator, Voltmeter and Ammeter for charging the battery from external mains. This will be in addition to the battery charging alternator or dynamo fitted on the engine.All the components in the control panel shall be properly mounted, duly wired and labeled. Suitable terminals are to be provided for panel incoming and outgoing connections. System opeartion facility provided shall afford the following operational requirements. Necessary instruments and accessories such as voltmeter, power factor meter, KW meter, KWH meter, Ammeter, Frequency meter,battery charger complete in all respect as desired by engineer at site:- |
| 448 | INDOOR LT CABLES, CABLE TRAY & DWC PIPE: |
| 449 | XLPE INSULATED UN-ARMOURED CABLES (LOOSE):-Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:- |
| 450 | Overall size 70sq.mm (3½ Core) Un-armoured (Loose) |
| 451 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 452 | Double walled corrugated (DWC) HDPE pipe120/103.50mm (outer/ inner dia.) |
| 453 | CABLE TRAY:Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:- |
| 454 | Cable Tray Size 300mm x 50mm x 50mm (2mm thick) |
| 455 | Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections:- |
| 456 | Brass Gland for Aluminium cable 2/3/3½/4 Core size 70sq.mm |
| 457 | Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:- |
| 458 | Aluminium thimble cable Core size 25 -35sq.mm |
| 459 | Aluminium thimble cable Core size 70sq.mm |
| 460 | COPPER EARTHING |
| 461 | COPPER EARTHING (Upto 14 metre in Length):-iii- Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- (Body earthing & Neutral Earthing) |
| 462 | Earthing with 20mm x 3mm Copper Tape (upto 14Metre in Length) |
| 463 | Additional Length 20mm x 3mm thick Copper Tape |
| 464 | Providing Flood Lighting: |
| 465 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- |
| 466 | Overall size 1.5sq.mm (Un-sheathed) |
| 467 | XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE):Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- (For Flood Lights) |
| 468 | Overall size 10sq.mm (3Core) Un-armoured (On-Surface) |
| 469 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- |
| 470 | Double walled corrugated (DWC) HDPE pipe 63/51mm (outer/ inner dia.) |
| 471 | SHEET METAL CUBICAL PEDESTAL, TOWER STRUCTURES, HT & LT LINE ITEMS, MS CHANNELS, BRASS GLANDS, ALUMINIUM & COPPER THIMBLES: |
| 472 | Supply and erection of M.S. Channel bracket made from 100mm x 50mm of length 600mm and height 600mm with M.S. angle iron 40mm x 40mm x 5mm for installing metal halide flood light fitting on it. Bracket should be fixed/ welded with the existing pipe of cover shed. The bracket should be painted with one coat of primer and two coats of approved paint. (For Flood Lights on Parapet wall) |
| 473 | Supply and erection of SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772 (Recessed/ On surface), robustly constructed, safe & shock proof, rust & tamper proof of suitable inner & outer dimensions with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB's) complete in all respect as approved and desired by the Engineer In-Charge at site:- |
| 474 | SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772, inner dimensions 200mm x 140mm x 95mm with hinged water tight cover with locking arrangement (For Flood Lights on Parapet wall). |
| 475 | GALVANIZED IRON PIPES AND G.I. EARTHING:Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling).(For Cubical Pedestal) |
| 476 | Earthing with 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe with G.I. reducing socket 50mm x 15mm (upto 8Metre in length) |
| 477 | Additional length G.I. wire 8 S.W.G. (4mm dia.) in 15mm dia. G.I. pipe (On Surface) |
| 478 | Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections:- |
| 479 | Brass Gland for Aluminium cable 2/3/4 Core size 10sq.mm |
| 480 | Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:- |
| 481 | Aluminium thimble cable Core size 10 -16sq.mm |
| 482 | SHEET METAL CUBICAL PEDESTAL, TOWER STRUCTURES, HT & LT LINE ITEMS, MS CHANNELS, BRASS GLANDS, ALUMINIUM & COPPER THIMBLES:CUBICAL PEDESTAL: Supply and erection of Sheet metal cubical pedestal made from 50mmx50mmx6mm thick MS angle iron frame with 5 sides welded & covered with MS sheet 2mm thick & front side hinged with 4\\" hinges & locking system with single/ double door openable placed on MS strip of size 12.5mm x 2.5mm thick welded with MS sheet, 4Nos. legs of 50mmx50mmx6mm thick MS angle iron each of 600mm long with MS sheet 100mmx100mmx6mm thick at the bottom end of the legs. Front door welded x-sectionally with MS flat 25mmx5mm. The front side with MS sheet each 75mm wide & a bend of 75mm width outwards & inwards on all sides with tappered top 200mm high and pedestal with 4 Nos. supporting members each of MS flat 50mmx6mm thick according to cubical size duly welded & complete pedestal to be painted with 1 coat of red oxide & 2 coats of paint & bonding to the existing earth. The Pedestal platform should be filled with 1:2:4 cement concrete mixture and erected 150mm high from the top of the cement concrete platform. The job is to be completed as approved by Engineer-in-charge:- |
| 483 | Cubical Size 1200mm high, 900mm wide and 350mm deep with platform dimensions 1000mm x 450mm x 450mm |
| 484 | MS SHEET ENCLOSURE FOR MCCB's:Supply & Erection of indoor type MCCB enclosure of suitable size having provision for MCCB with extended rotary handle. The Enclosure shall be made from 14/16 SWG CRCA sheet, confirming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/top with cable glands etc. The sheet metal is sprayed with corrosion resistant etch primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:- |
| 485 | MS Sheet Enclosure having provision for MCCB 40-160Amp.with extended rotary handle (Approx. Size 500mm x 300mm x 200mm) |
| 486 | MCCB's (MOULDED CASE CIRCUIT BREAKER):Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- |
| 487 | MCCB Four Pole 40amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting |
| 488 | TIMER:- Supply and erection of Switch S/E of Microprocessor Based Street Light Controller with digital time switch daily programmed with stand by lithium battery with back up of 6 years with min. time between 2 switching operations is 1 minute, three pole power contactors 40A. with coil voltage 220-230V AC with 1 no. aux. contact NO, MCB 2 pole 40amp. (C-Curve, 10kA) & power wiring with single core PVC insulated FR cable 10 sq. mm and control wiring with PVC insulated FR cable 1 sq. mm, 1 no. two position selector switch to bypass timer and other accessories & petty material (din rail, 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts) should be fixed on bakelite sheet 6mm thick to be mounted in a IP54 surface/ flush mounting powder coated sheet metal (1.60mm thick) cabinet having size 450mm x 600mm x 150mm to switch ‘ON’ all the 3 phases & switch ‘OFF’ 3 phases pre-fixed timings complete in all respect as per satisfaction of Engineer-in-charge:- |
| 489 | Street Light Controller (For Three Single Phase Circuits) with 3 Nos. Three Pole Power Contactors 40A, 1 no. aux. contactor 6 amp. (2NO+2NC) with coil voltage 220V AC, 3 Nos. MCB 2 Pole 40amp. (C-Curve,10kA) & petty material (Din rail, 2 Nos. 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts) |
| 490 | Supply and erection of LED Flood Light 120 watt, AC supply voltage 140-270 volts, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED (with wattage 1 to 5 watt) with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No: AT/2021/GL/1410-1422 Dated: 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab. |
| 491 | Providing Solar Power Generation System: |
| 492 | Grid interactive PV System Solar Power Plant of 44KWp: |
| 493 | Supply, Installation, testing & Commissioing of Grid interactive PV System Solar Power Plant (i.e connected to utility grid) of Minimumcapacity including required quantities of SPV modules (High power density bifacial monocrystalline solar modules with a capacity of +500 watts) formed into arrays, their mounting arrangement, Power conditioning units (i.e String Solar Inverter with 2Nos. GI Chemical earthing with suitable size GI strip upto string inverter and AC & DC distribution panel), required DC & AC distribution panels with surge protection units, cabling from terrace to main distribution board through Cable tray, Bi Directional Energy Meter, Provision of Lightening Arrestor & 2 Nos. GI chemical earthing with suitable size GI strip upto Lightning arrestor, Hot dip galvanized MS Mounting Structures (1No. GI Chemical earthing with suitable size GI strip upto mounting structure) should be designed to withstand the speed for the wind Zone of the location (150 Km/hr-170 Km/hr) Complete in all respect with transportaion, fabrication, labour & Civil Work etc. Features :- 1. Solar PV Module warranty 25 Years & certified under IS/IEC 61730 I & II IS/IEC 61701 & IS/EC 142862. Power Conditioning unit (string solar inverter) & certified under IEC/EN 62109-1, IEC/EN 62109-2, EN 61000-6-2, EN 61000-6-3, IEC 61683, EN 50530, IEC 60068-2-1, 2, 14, 30, EN 605293. Structure 25 Years service life with AMC & certified under IS 2062 20114. Complete Plant insurance for the period of 5 Years (Excluding Theft of the Material)5. Annual Maintenance contract for the period of 10 YearsConditions:# The Plant will be installed as per MNRE and GOI guidelines and specifications. (Detail of material as per Annexure-I attached)#The work will got done from approved MNRE (Misitry of New and Renewable Energy)/ PEDA (Punjab Energy Development Agency) contractor/PWD enlisted Contractor subject to condition that PWD enlisted contractor will get work done from MNRE (PEDA approved Contractor)#The capacity of solar power plant my increase or decrees as availability of site it can also be totally removed from executive endThe Rate are inclusive of Bidirectional meter testing charges, PSPCL connection charges, unidirectional meter cost & all types of taxes including GST |
| 494 | Providing Façade Lighting |
| 495 | Supply ,erection, testing and Commissioning of exterior BIS registered 3000K CCT LED Spot lighting luminaire for Architectural Designer lighting with Die-cast aluminium housing, powder-coated finish, Clear toughened glass, of Total System wattage not exceeding 12W with Min system lumen output >=900lm with all LEDs on ,the system system lumen efficacy >80lm/w. Luminaire should be complete with dedicated Lens for each LED offering beam angle of different types such as narrow, medium, wide or elliptical as per the site requirement. teh product should have fins in concentric rings only. Fixture shall be suitable to operate at an ambient temperature range of -10°C to 50°C and complete luminaire shall be IP66 and IK06 rated. LED Life time shall be at least L70B50 @50000 burning hours at 35°C. The product should be proper with IP 67 rated fused connector. The product should be Designer and should have a glare shield inbuilt in the casting of the product . Fixture should be >80 CRI and SDCM < 5. LED chip source should be of make Osram, Nichea, Cree, Lumiled/ Philips only. Luminaire shall be used with a remote BIS IP 66/67 potted driver and capable of operating at line voltage from 100-300 Vac, 50Hz with power factor > 0.9. To be supported with Product test reports - LM79, BIS Report and LEDs Test Reports. Luminaire shall be conforming to BIS i.e. IS 10322 (Part 5/Sec 5) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.complete in all respects as approved and desired by the Engineer in-charge at site. |
| 496 | Supply ,erection, testing and Commissioning of exterior BIS registered 3000K CCT LED Spot lighting luminaire for Architectural Designer lighting with Die-cast aluminium housing, powder-coated finish, Clear toughened glass, of Total System wattage not exceeding 15W with Min system lumen output >=1150 lm with all LEDs on ,the system system lumen efficacy >80lm/w. Luminaire should be complete with dedicated Lens for each LED offering beam angle of different types such as narrow, medium, wide or elliptical as per the site requirement. teh product should have fins in concentric rings only. Fixture shall be suitable to operate at an ambient temperature range of -10°C to 50°C and complete luminaire shall be IP66 and IK06 rated. LED Life time shall be at least L70B50 @50000 burning hours at 35°C. The product should be proper with IP 67 rated fused connector. The product should be Designer and should have a glare shield inbuilt in the casting of the product . Fixture should be >80 CRI and SDCM < 5. LED chip source should be of make Osram, Nichea, Cree, Lumiled/ Philips only. Luminaire shall be used with a remote BIS IP 66/67 potted driver and capable of operating at line voltage from 100-300 Vac, 50Hz with power factor > 0.9. To be supported with Product test reports - LM79, BIS Report and LEDs Test Reports. Luminaire shall be conforming to BIS i.e. IS 10322 (Part 5/Sec 5) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. complete in all respects as approved and desired by the Engineer in-charge at site. |
| 497 | Supply ,erection, testing and Commissioning of exterior BIS registered 3000K CCT LED flood lighting luminaire for facade lighting with Die-cast aluminium housing, powder-coated finish, Clear toughened glass, of Total System wattage not exceeding 36W with system lumen output >=3000lm with all LEDs on , with system lumen efficacy >85lm/w. Luminaire should be complete with dedicated Lens for each LED offering beam angle of different types such as narrow, medium, wide or elliptical as per the site requirement. Fixture shall be suitable to operate at an ambient temperature range of -10°C to 50°C and complete luminaire shall be IP66 and IK08 rated. LED Life time shall be at least L70B50 @50000 burning hours at 35°C. The product should be proper with IP 67 rated fused connector. The product should be square and dai casting of the product. Fixture should be >80 CRI and SDCM ≤ 5. LED chip source should be of make Nichea, Osram, Cree, Lumiled/ Philips/Seoul only. Luminaire shall be complete with integrated BIS IP 66/67 potted driver and capable of operating at line voltage from 100-300 Vac, 50Hz with power factor > 0.9. To be supported with Product test reports - LM79, BIS Report and LEDs Test Reports. Luminaire shall be conforming to BIS i.e. IS 10322 (Part 5/Sec 5) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. complete in all respects as approved and desired by the Engineer in-charge at site. |
| 498 | Supply ,erection, testing and Commissioning of wall washer exterior BIS registered 3000K LED luminaire for facade lighting with extruded aluminium housing, powder-coated finish, Clear toughened glass, of Total System wattage not exceeding 12W with all LEDs on, minimum system lumen efficacy >80lm/w. Luminaire should be complete with dedicated Lens for each LED offering beam angle of different types such as narrow, medium, wide or elliptical as per the site requirement. Fixture shall be suitable to operate at an ambient temperature range of -10°C to 50°C and complete luminaire shall be IP66 and IK06 rated. LED Life time shall be at least L70B50 @50000 burning hours at 35°C. Fixture should be >80 CRI and SDCM <5. LED Chip source should be of make Nichea, Osram, Cree, Lumiled/Philips only. Luminaire shall used with remote driver BIS IP 66/67 potted driver and capable of operating at line voltage from 90-305 Vac, 50Hz with power factor > 0.9. To be supported with Product test reports - LM79, BIS Report and LEDs Test Reports. Luminaire shall be conforming to BIS i.e. IS 10322 (Part 5/Sec 5) and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required.complete in all respects as approved and desired by the Engineer in-charge at site. |
| 499 | Supply ,erection, testing and Commissioning of LED Foot/Wall Light Wattage : 3W,Operating Voltage : AC230V,Colour: 3000K ,Beam Angle : Asymmetric,IP Rating : IP54,IK Rating: IK02 with flushed box in wall complete in all respects as approved and desired by the Engineer in-charge at site. |
| 500 | Supply ,erection, testing and Commissioning of Power Supply Dali - AC100~200V input, DC24V output, 200W, constant voltage power supply IP Rating : IP67 complete in all respects as approved and desired by the Engineer in-charge at site. |
| 501 | Supply ,erection, testing and Commissioning of Ground Burial Light Wattage: 12W, Operating Voltage : DC24V, CCT: 3000K, Beam Angle : 15°, IP Rating : IP67, IK Rating : IK08 complete in all respects as approved and desired by the Engineer in-charge at site. |
| 502 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:- |
| 503 | Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail