| 1 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required:- |
| 2 | Short Point :- |
| 3 | Medium Point :- |
| 4 | Long Point :- |
| 5 | Providing and fixing of 3 pin 6/10 amps plug point with modular type 6/10 amps switch and socket including connection with 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modular switch board, earthing the 3rd pin etc. as required:- |
| 6 | Providing and fixing of 3/6 pin 16/20 amps plug point with modular type 16/20 amps switch and socket including connection with 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required:- |
| 7 | Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required. |
| 8 | 2 X 1.5 sq mm |
| 9 | 2 X 2.5 sq mm |
| 10 | 2 X 4 sq mm |
| 11 | 2 X 6 sq mm |
| 12 | 4 X 4 sq mm |
| 13 | 4 X 6 sq mm |
| 14 | 4 X 10 sq mm |
| 15 | Wiring for Circuit/Sub-main with the following sizes PVC insulated Copper conductor cable (FR) in PVC conduit including connection etc. as required:- |
| 16 | 2 X 1.5 sq mm |
| 17 | Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:- |
| 18 | 1 X 1.5 sq mm |
| 19 | 1 X 2.5 sq mm |
| 20 | Supplying and laying of following sizes XLPE insulated PVC sheathed Aluminium conductor Un-armoured cable including necessary connection etc as required. |
| 21 | 3 core 4 Sq mm |
| 22 | 3.5 core 25 Sq mm |
| 23 | Earthing with 40 mm dia G.I. Earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top CI cover plate size 12\\"x 12\\" having locking arrangement including CC work, holes on earth pipe etc. as required. |
| 24 | Extra for using salt (5 kg) and charcoal (46kg) for pipe earth electrode as required. |
| 25 | Proving and fixing / drawing of 4.06 mm dia (8 SWG) G.I. wire on surface or in existing G.I/ PVC/ Polythene pipe for loop earthing as required. |
| 26 | Providng and laying 15mm dia(medium gauge) G.I. pipe for drawing of 4.06mm (8SWG) dia G.I./ Copper wire for earth connection from earth electrodes etc as required. |
| 27 | Supplying and installation of Switch disconnector fuse unit (main switch) of the following ratings with all accessories including necessary connection etc. as required:- |
| 28 | 63 amps TPN 415 volts front handle cubical main switch (HRC):- |
| 29 | Supplying and installation of Bus bar chamber of the following ratings and sizes made of steel sheet enclosure with all accessories including necessary connection etc. as required:- |
| 30 | 63 amps 415 volts four strip Copper busbar chamber 6 ways of size (455mmx330mmx120mm):- |
| 31 | Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required. |
| 32 | (2+4) / 6 way SPN MCB DB (double door):- |
| 33 | (2+6) / 8 way SPN MCB DB (double door):- |
| 34 | (2+10) / 12 way SPN MCB DB (double door):- |
| 35 | 4 way horizontal TPN MCB DB (Double door):- |
| 36 | Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connection as required:- |
| 37 | 6 to 32 amps SP MCB:- |
| 38 | 6 to 32 amps DP MCB:- |
| 39 | 40/50/63 amps FP MCB:- |
| 40 | Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):- |
| 41 | Surface mounted box type batten suitable for single 18/20 watt integrated LED tube lamp (without lamp):- |
| 42 | Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):- |
| 43 | 60 watt LED flood light fixture with integral driver and secondary lens (IP 66):- |
| 44 | 40 watt LED post top light fixture with integral driver and high quality polycarbonate diffuser (IP 65):- |
| 45 | 45 watt LED street light fixture with integral driver and secondary lens (IP 66):- |
| 46 | 60 watt LED street light fixture with integral driver and secondary lens (IP 66):- |
| 47 | 6 watt/10 watt LED Bulkhead light with high quality polycarbonate diffuser (IP 65):- |
| 48 | Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:- |
| 49 | 18/20 watt LED tube with integral driver and polycarbonate diffuser (50000 burning hours and minimum lumen output of 100 lm/watt):- |
| 50 | 12 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :- |
| 51 | Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies, shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) (ISI marked, BEE 1 star/minimum service value 4.0 m3/min/W) : - |
| 52 | Supplying & installation of 450 mm sweep 1400 rpm metalic body exhaust fan including connection etc as required (ISI marked) :- |
| 53 | Supplying & installation of 400 mm sweep AC wall mounting fan with metal blade including connection etc as required:- |
| 54 | Supplying and fixing of the following sizes GI (in recess) and plastic (on surface) modular switch boards etc. as required. |
| 55 | 1-2 module plastic switch board:- |
| 56 | Supplying and fixing of the following sizes modular type cover plates for GI/plastic modular switch boards etc. as required. |
| 57 | 1-2 module :- |
| 58 | Supplying and fixing of the following modular accessories including necessary connection etc. as required. |
| 59 | 3 pin 6/10 amps socket outlet (2M):- |
| 60 | Blank plate (1M):- |
| 61 | 4 step fan regulator (1M):- |
| 62 | Supplying and fixing of the following electrical accessories including necessary connection etc. as required. |
| 63 | 32 amps DP kit kat switch:- |
| 64 | Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required:- |
| 65 | 25 mm dia |
| 66 | 40 mm dia |
| 67 | Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 nos legs (25mmx25mmx5mm MS angle 20 cm long) finished with red oxide and 2 coat synthetic enamel paint including necessary cc work, mending the damages & painting etc as required:- |
| 68 | Supplying & fixing of 12mm thick marine plywood conforming to IS:710 with necessary painting etc as required:- |
| 69 | Drawing of armoured/un-armoured cable with proper saddling etc as required:- |
| 70 | Supplying and fixing of thermoplastic cable junction box with connectors suitable for following sizes cable : - |
| 71 | 1.5 sqmm - 4 sqmm Cable:- |
| 72 | Supplying and fixing of aluminium terminal ends (LUGS) - long barrel of following sizes : - |
| 73 | 4/6 sq mm |
| 74 | 25 sq mm |
| 75 | 16 sq mm |
| 76 | Supplying and fixing of Copper terminal ends (LUGS) - long barrel of following sizes: - |
| 77 | 2.5 sq mm |
| 78 | 4 sq mm |
| 79 | 6 sq mm Please Enable Macros to View BoQ information |