| 1 | Taking down shutter of any description not exceeding 1 Sqm all as specified and directed. |
| 2 | M&L for brick work with old size sub-class ‘B’ bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar (1:6), complete all as specified & directed. |
| 3 | M&L for 15mm thick rendering in cement mortar (1:6) on brick work or concrete surfaces of walls, finished the surface even & smooth without using extra cement complete all as specified and as directed by Engineer-in-charge. |
| 4 | Taking down cement plaster from brick wall/stone wall, racking out joint, hacking for key, scrubbing down with water all as specified and directed. |
| 5 | M&L for preparation of new plastered surfaces of walls and applying two coats of OBD over a coat of wall putty 1mm thik complete all as specified and as directed. |
| 6 | M&L for comlete removal of existing treatment of walls by washing, rubbing down and stopping of distempered surfaces and applying one coat of oil emulsion distemper (OBD) of approved shade/tint over-1mm thick wall care putty complete all as specified & directed. |
| 7 | Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises |
| 8 | M&L vitrified ceramic tiles 8-9mm thick (square/rectangular) area of each tile exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors and skerting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:6 as per specified and as directed |
| 9 | M&L for Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes with Cement plaster 1:4 all as speicfied and directed. |
| 10 | M&L for non Skid ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with surrounding surface all as directed. |
| 11 | M&L for glazed ceramic tiles in vertical surface 300x300mm x 7mm /300X450X7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match with surrounding surface all as directed. |
| 12 | M&L for CM(1:4) 10 mm rendering on vertical surfaces all as specified and directed. |
| 13 | Taking down chowkat or frame with shutters wooden/ aluminimum/iron area not exc. 1.5 Sqm each (without taking off the wooden shutters from the frame) including cutting holes for hold fasts complete all as specified and directed. |
| 14 | S&F aluminium poweder coated frame for doors, windows, ventilators, partitions, powder coated of any colour as approved (Thickness or powder coating not less than 50 micron) with one or more rebates including joining cleat for fixing etc. complete all as specified & as directed. |
| 15 | S&F aluminium powder coated window and ventilator shutters, without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified & directed. |
| 16 | S&F 4.0mm thick sheet glass, ordinary quality, coloured/tinted/silver finish and glazing with oil putty including rubber beading cleats etc in square n exc 0.5 sqm in each pane complete all as specified and as directed |
| 17 | S & F for Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. |
| 18 | S&F Aluminium wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples, complete all as specified and directed. |
| 19 | M&L for 18 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking plateforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shed of granite including and over 15 mm thick screed bed or bedding layer of mortar 1:6 all as specified and directed. |
| 20 | Taking down chowkat or frame with shutters wooden/ aluminium/iron area exc 1.5 Sqm but not exc 4 Sqm each (without taking off the wooden shutters from the frame) including cutting holes for hold fasts complete all as specified. |
| 21 | S&F Mild steel work as in band, straps, supports for RWP, clamps, hold fasts, wall ties, hooks & pintle hinges and similar small articles conforming to Fe-290-0 or Gde E-165 complete all as specified and as directed by Engineer-in-Charge. |
| 22 | S&F solid PVC door frame of size 50mm x 47mm made out of 5 mm wood grain printed PVC sheet reinforced with MS square tube and edgeswill be painted to match will printed sheet fixed in opening as per specification & drawings complete all as specified and as directed. |
| 23 | S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel heaving a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing, complete all as specified & directed. |
| 24 | Supply & Fixing 2nd class hard wood plain, soild straight chowkats and frames of wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed by Engineer-in-Charge |
| 25 | S&F for 30 mm thick flush shutters, solid core construction with block board core and plywood face panels, commercial type on both sides and fitted to chowkhats complete all as specified and directed. |
| 26 | M&L for preparation of new or untreated painted wood and wooden based surfaces of any description not other wise described over 10 centimetre width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed. |
| 27 | S&F Mild Steel Butt hinges, medioum weight, cold rolled, of size 100 mm complete all as specified and directed. |
| 28 | S&F Aluminium handle, cast type anodized size of handle 150 mm complete all as specified and as directed. |
| 29 | S&F Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed length of bolt 250 mm complete all as specified and as directed. |
| 30 | S&F 150 mm long mild steel barrel tower bolt, stove enameled black with bright bolt complete all as specified and directed. |
| 31 | S&F aluminium body hydraulically Door closer regulated, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed as in repairs complete, all as specified and directed. |
| 32 | Demolition of concrete in ground floors and pavings not exc 15 cm thickness (below or above ground level) alll as specified and directed. |
| 33 | M&L for 75mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate in plinth protection, sub base etc finishing cement concrete surface even and fair without using extra cement complete all as specified and as directed by Engineer-in-Charge. |
| 34 | Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets complete, all as specified and directed . |
| 35 | Provision of perforated/semi-perforated 4mm thick ceiling tiles of size 595mm x 595mm for insulation and acoustic purposes including aluminium anodised section of size, wall angle 30mm x 25mm x 2mm thick, main / cross tee-section 15mm x 15mm x 1.4mm and suspended with 4mm dia GI wire of suitable length and including fixed & aluminium snap grid all as per clause 10.38.1 of SSR Part-I and as per manufacturer’s instructions complete all as specified and as directed by Engineer-in-Charge. |
| 36 | M& L for Surface dressing of soft and loose soil not exc 15 cm deep as specified and directed. |
| 37 | M&L for removing excavated surplus soil/material not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed |
| 38 | M&L for hardcore of gauge not exc. 63 mm, deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface as in plinth protection. |
| 39 | M&L for PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in sub base, Cement concrete in foundations, filling and mass concrete surface finished fair and even, complete all as specified & directed. |
| 40 | M&L for Prepolished designed and coloured chequered cement concrete tiles with grey cement & pigment of size 30cmx30cmx22 to 25mm thick set & jointed with cement slurry over & including 15 mm thick bedding layer of cement sand mortar (1:6) and pointed with grey cement, complete all as specified & directed. |
| 41 | M&L for plain cement concrete (1:2:4) type B1, using 20 mm graded crushed stone aggregate as in coping, filling on holdfst,benching including necessary form work, complete, all as specified and directed. |
| 42 | Dismantling asbestos corrugated or semi corrugated sheets as in roof covering including ridge etc complete all as directed by Engr-in-charge. |
| 43 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete, all as specified and directed . |
| 44 | Dismantling wrought iron or mild steel work of any dscription not otherwise provided for complete all as specified and directed. |
| 45 | Excavating post holes or similar holes, each not exceeding 0.5 Cu. M, getting out in Soft/ loose soil and removing surplus soil to a distance not exc 50m & making good surface all as specified and directed. |
| 46 | M&L for plain Cement Concrete Type C2 1:3:6 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete all as directed. |
| 47 | S & F Mild steel roof trusses (framed), Trussesd, purlins, crane grantries, rails and framings and heavy bracket framing (Beam,tee, angle, channel or flat sections) confrming to Fe 410-W including cleats, distance pieces etc |
| 48 | M & L for two coats of synthetic enamel paint to iron & steel surfaces over a coat of red oxide primer all as directed. Please Enable Macros to View BoQ information |