| Sl. No. | Item Description |
| 1 | Clearing jungle including uprooting of rank vegatations grass, bush, wood trees and saplings of girth upto 30cm. Measured at a height of 1 metre above ground level & removal of rubbish upto a distance of 50 metres outside the periphery of area cleared.(DSR-2.31) |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil.(DSR-2.6.1) |
| 3 | Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials.(DSR-2.6.1+2.26.1) |
| 4 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.(DSR-2.27) |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources.(DSR-4.1.8) |
| 6 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4)Treatment junction of wall and the floor 7.5 liters /sqm (5)Treatment of soil along external perimeter of building 7.5 liters/sqm. (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution)Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement:2 coarse sand) to match the existing floor.With Chlorpyriphos/ Linadane E.C. 20% with 1% concentration.(DSR-2.35.3.1) |
| 7 | Providing & laying in position machine batched and machine. Mixed design mix M-25 grade cement concrete for reinforcement cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying Excluding the cost of centering, shuttering , finishing and but excluding reinforcement , including admixtures in recommended proportion as per IS : 9103 to acclerate, retarder for setting of concrete/ improve workability without impairing strength and durability as per direction of Engineer-in-charge. R.C.C. work Upto plinth Lvl. (M-25) Note : Concrete of M25 grade with minimum cement(Footing, Column &Beam, )(DSR-5.33.1.1) |
| 8 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR-6.1.2) |
| 9 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources).(DSR-4.1) |
| 10 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.(DSR-4.13) |
| 11 | 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand)(DSR-13.5.1) |
| 12 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.(DSR-2.25) |
| 13 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.(DSR-2.25a) |
| 14 | UPTO PLINTH LVL.Centering and shuttering including strutting, propping etc. and removal of form for all heights :Foundations, footings, bases of columns, etc. for mass concrete.(DSR-5.9.1) |
| 15 | Providing & laying in position machine batched and machine. Mixed design mix M-25 grade cement concrete for reinforcement cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying Excluding the cost of centering, shuttering , finishing and but excluding reinforcement , including admixtures in recommended proportion as per IS : 9103 to acclerate, retarder for setting of concrete/ improve workability without impairing strength and durability as per direction of Engineer-in-charge. R.C.C. work above plinth Lvl. (M-25) Concrete of M25 grade with minimum cement(R.C.C. in Column, Lintel, Slab & Beam)(DSR-5.33.2.1) |
| 16 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR-6.4.2) |
| 17 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR-6.4.1) |
| 18 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions ofwalls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. Finishing the surface with 20 mm thick jointless cement mortar of (d) mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved byEngineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge With average thickness of 120 mm and minimum thickness at khurra as 65 mm. (DSR-22.7.1) |
| 19 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. (a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.(DSR-9.21.1) (Single Leaf) |
| 20 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. (b) Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured).(DSR-9.21.1+9.22) (double Leaf) |
| 21 | Providing and fixing 25 mm thick shutters for cup board etc. :Panelled or panelled & glazed shutters : Second class marked anodised aluminium butt hinges with necessary screws. 25 mm thick shutters for cup board (DSR-9.16.1.1) |
| 22 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete (Hold fast)(DSR-10.2) |
| 23 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works(DSR-10.25.2) |
| 24 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size(DSR-10.15.1) |
| 25 | Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete.With 2nd class teak wood beading 62X19 mm(DSR-9.135.1) |
| 26 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces(DSR-10.5.1) |
| 27 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. (DSR-5.22A.6) |
| 28 | 12 mm cement plaster of mix :1:6 (1 cement: 6 coarse sand) (DSR-13.4.2) |
| 29 | 15 mm cement plaster on rough side of single or half brick wall of mix:1:6 (1 cement: 6 coarse sand)(DSR-13.5.2) |
| 30 | 6mm Thick plaster on ceiling in 1:3 cement & fine sand mortar with all complete as per i/c (DSR-13.16.1) |
| 31 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.(DSR-5.3) |
| 32 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate.(DSR-11.3.1) |
| 33 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR-4.1.3) |
| 34 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm (DSR-11.41.2) |
| 35 | Providing and laying vitrified tiles in flooring or skirting in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm (DSR-11.46.2) |
| 36 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick. (DSR-11.26.1) |
| 37 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.(DSR-11.27) |
| 38 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. (DSR-11.37) |
| 39 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. (DSR-11.37A) |
| 40 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. (Area of slab upto 0.50 sqm) (DSR-8.2.2.1) |
| 41 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 Itr/10 sqm over an under coat of primer applied @ 0.80 Itr/10 sqm of approved brand and manufacture (DSR-13.48.3) |
| 42 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 Itr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture. (DSR-13.48.2) |
| 43 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)(DSR-13.46.1) |
| 44 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre (For Internal wall surface)(DSR-13.41.1) |
| 45 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.(DSR-13.8) |
| 46 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes(DSR-10.30.1) |
| 47 | Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . (MR) |
| 48 | Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete (a) 250 mm x 10mm (MR) |
| 49 | Providing and fixing stainless steel handles with screws etc. complete (a) 125 mm(MR) |
| 50 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete.(DSR-14.34) |
| 51 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover(DSR-10.6.1) |
| 52 | Providing and fixing ball bearing for rolling shutters. (DSR-10.7) |
| 53 | 6 mm cement plaster 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams(DSR-13.17) |
| 54 | Providing & laying of light cinder filling under floor of toilets & other sunken roofs.(MR) |
| 55 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.(DSR-22.5) |
| 56 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge.(DSR-10.28) |
| 57 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin-charge .The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding.(DSR-14.72) |
| 58 | Centering and shuttering including strutting, propping etc. and removal of form for all heights : (a) Suspended floors, roofs, landings, balconies and access platform.(DSR-5.9.3) |
| 59 | Centering and shuttering including strutting, propping etc. and removal of form for all heights :(b) Lintels, beams, plinth beams, girders, bressumers and cantilevers. (FOR LINTEL & BEAM)(DSR-5.9.5) |
| 60 | Centering and shuttering including strutting, propping etc. and removal of form for all heights :(c) Columns,Pillars, Piers, Abutments, Posts and Struts.(DSR-5.9.6) |
| 61 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever requiredWhite Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests(DSR-17.1.1) |
| 62 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white plastic seat and lid(DSR-17.2.1) |
| 63 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap.(DSR-17.7.4) |
| 64 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required Kitchen sink with drain board 510x1040x200mm(DSR-17.10.1.3) |
| 65 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. Semi rigid pipeb) 40mm dia(DSR-17.28.1.2) |
| 66 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (DSR-17.31) |
| 67 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS :2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and brackets, cutting and making good the walls and floors wherever required(b) Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern(DSR-17.5.2) |
| 68 | Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade(DSR-8.10.2) |
| 69 | Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube upto 1 meter long with S.S. triangular plate for Eureopean type W.C. of quality and make as approved by engineer-in-charge.15mm nominal bore(DSR-17.16A) |
| 70 | Providing and fixing CP Brass 32 mm size Bottal Trap of approved quality & make and as per thedirection of Enginer-in-charge.(DSR-17.22A) |
| 71 | Providing and fixing CP Brass Single lever lelephonic wall mixture of quality & make and as per thedirection of Enginer-in-charge. a) 15mm dia nominal dia.(DSR-) |
| 72 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inleta) 100 mm diameter(DSR-18.22.1) |
| 73 | Providing and fixing PTMT Liquid soap container 109 mm wide ,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms.(DSR-17.71) |
| 74 | Providing & fixing PTMT towl rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fitting arrangement of approved quality and colour. 600 mm. long towl rail length of 645 mm. width 78 mm. and effective height of 88 mm, weighing not less than 190 gms.(DSR-17.73.2) |
| 75 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. 110mm diameter(DSR-12.41.2) |
| 76 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. Bend 87.5 degree110 mm Bend Shoe (Plain) 110 mm Shoe(DSR-12.42.6.2) |
| 77 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete.(DSR-12.22) |
| 78 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110mm (DSR-12.43.2) |
| 79 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.(DSR-12.44) |
| 80 | Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc. (internal work) Exposed on wall50mm dia nominal bore (DSR-18.10.6) |
| 81 | Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality. 50mm dia nominal bore.(DSR-18.40.6) |
| 82 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. internal work -Exposed on wall20mm dia nominal outer dia pipes(DSR-18.7.2) |
| 83 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. internal work -Exposed on wall25mm dia nominal outer dia pipes(DSR-18.7.3) |
| 84 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. internal work -Exposed on wall50mm dia nominal outer dia pipes(DSR-18.7.6) |
| 85 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 15mm dia nominal outer dia pipes(DSR-18.8.1) |
| 86 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 20mm dia nominal outer dia pipes (DSR-18.8.2) |
| 87 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. 25mm dia nominal outer dia pipes(DSR-18.8.3) |
| 88 | Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 15mm nominal bore(DSR-18.49.1) |
| 89 | Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15mm nominal bore(DSR-18.51.1) |
| 90 | Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 15mm nominal bore(DSR-18.53) |
| 91 | Providing & fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.(DSR-18.53A) |
| 92 | Providing and fixing gun metal gate valve with wheel of approved quality. 25mm dia nominal bore(DSR-18.17.1) |
| 93 | Providing and fixing gun metal gate valve with wheel of approved quality. 20 mm dia nominal bore(DSR-18.17.1A) |
| 94 | Providing and fixing gun metal gate valve with wheel of approved quality. 50mm dia nominal bore(DSR-18.46.6) |
| 95 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia.in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia.(DSR-2.10.1.2) |
| 96 | Providing and laying Non pressure NP2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. 150mm dia. R.C.C. pipe(DSR-19.6.2) |
| 97 | Providing and laying Non pressure NP2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. 250mm dia. R.C.C. pipe(DSR-19.6.3) |
| 98 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of S.W./R.C.C. pipes including bed concrete as per standard design 150mm diameter (DSR-19.3.2) |
| 99 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of S.W./R.C.C. pipes including bed concrete as per standard design 250mm diameter (DSR-19.3.4) |
| 100 | Providing and fixing square mouth S.W. Gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design: 150 x 100 mm. size P type With Sewer bricks conforming to IS : 4885(DSR-19.4.2.2) |
| 101 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With FPS bricks of class designation 75 (i) For Sewer Line(DSR-19.7.1.1) |
| 102 | Extra for depth of man hole size 90x80 cm (DSR-19.8.1.1) |
| 103 | Inside size 90x120 cm & 90 cm deep including C.I. cover with frame (medium duty) total wt. of cover & frame to be not less than 116 Kg (wt. of cover 58 Kg & wt. of frame 58 Kg.(DSR-19.7.2.1) |
| 104 | Extra for depth of man hole size 90x120 cm (DSR-19.8.2.1) |
| 105 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar(DSR-19.15.1) |
| 106 | Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before with supply and cost of other fIttlings such as elbow,bend,tee and y-tee,Cowel including supply of all marerial labour and T&P. Required for proper completion of work. 75 mm O.D.(MR) |
| 107 | Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before with supply and cost of other fIttlings such as elbow,bend,tee and y-tee,Cowel including supply of all marerial labour and T&P. Required for proper completion of work. 110 mm O.D.(MR) |
| 108 | Supply and fixing of UPVC S.W.R. pipe nahni trap size 100x75,110/90 mm confirming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali.(MR) |
| 109 | Supply and fixing of UPVC S.W.R. Cowel confirming to IS-14735. Size 110 mm (MR) |
| 110 | Providing & Fixing C.P. Brass Health Faucet - Make-Jaquar (MR) |
| 111 | External Water SupplyExcavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. Pipes, cables etc. not exceeding 80mm dia.(DSR-2.10.1.1) |
| 112 | Provding and fixing gun metal non return valve of approved quality (screwed end) 80 mm nominal bore Vertical(DSR-18.19.6.2) |
| 113 | Providing & fixing G.I. pipes complete with G.I. fittings including tenching and refilling etc. External work 50mm nominal bore.(DSR-18.12.6) |
| 114 | Providing & fixing G.I. pipes complete with G.I. fittings including tenching and refilling etc. External work 80mm nominal bore.(DSR-18.12.8) |
| 115 | Providing & fixing sand of grading zone V or coaser grade alround the G.I. Pipes in external work. 50 mm diameter pipe(DSR-18.41.6) |
| 116 | Providing & fixing sand of grading zone V or coaser grade alround the G.I. Pipes in external work. 80 mm diameter pipe(DSR-18.41.8) |
| 117 | Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. 80 mm nominal bore(DSR-18.17.6) |
| 118 | Constructing masonry Chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand ) for sluice valve, with C.I. surface box 100mm top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With F.P.S. bricks(DSR-18.33.1) |
| 119 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 50 to 80 mm dia nominal bore(DSR-18.13.2) |
| 120 | Supply, installing, testing and commissioning of non clog submersible type drainage / dewatering pumpset with panel Type-Vertical Centrifugal Make-LUBI (1 working + 1 Standby) = 1 Set Discharge in LPH : 8000 LPH Head in Mtrs. : 8-10 Mtr Motor Power--1.50 HP RPM-2900 (MR) |
| 121 | Supply, installing, testing and commissioning of Vertical multistage pump for water supply with panel. Type-Vertical Multistage pump Model-LCR15-05 Make-LUBI (1 working + 1 Standby) = 1 Set Discharge in LPH : 15000 LPH Head in Mtrs. : 60 Mtr Motor Power-5.50HP RPM-2900 (MR) |
| 122 | Earth work in excavation by mechanical means (Hydraulic excavatior)/manual means over areas(exceeding 30cm in depth. 1.5m in width as well as 10sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. In all kind of soil upto 4.5m to 6.0m. Depth(DSR-2.6.1+2.26.1*3) |
| 123 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)(DSR-6.1.1) |
| 124 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Mild steel and Medium Tnsile steel bars.(DSR-5.22.1) |
| 125 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter(DSR-19.19.2.2) |
| 126 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-incharge, upto 90 metre depth below ground level. Drilling of 300mm dia bore hole manually.(DSR-23.1.1.1) |
| 127 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia(DSR-23.4.2) |
| 128 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.(DSR-23.5) |
| 129 | Supplying, filling, spreading & leveling coarase sand of size range 5mm, 1.5 mm to 2mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge.(DSR-23.7) |
| 130 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/medium/coarse, in required grading & size as per actual requirement, all complete as per direction of Engineer-in-charge.(DSR-23.8) |
| 131 | Constructing brick masonry manhole with 75 class designation F.P.S. bricks in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand: 4graded stone aggregate 20mm nominal size); foundation concrete 1:4:8 mix (1 cement :4 coarse sand: 8 graded stone aggregate 40mm nominal size) inside plasstering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. a) Inside size 60x60 cm & 60 cm deep including C.I. cover with frame (light duty) total wt. of cover & frame to be not less than 38 Kg (wt. of cover 23 Kg & wt. of frame 15 Kg.(AR) |
| 132 | 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4( 1 cement: 2 coarse sand: 4 gradeed stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2( 1 cement hardener mix: 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.(DSR-11.5) |
| 133 | Providing and fixing C.I. tee at the inlet and outlet of septic tank.(DSR-7087) |
| 134 | Providing & fixing 75mm dia vent pipes.(DSR-17.35.2.1) |
| 135 | Providing & fixing of 75mm dia cast iron terminal guard.(DSR-17.56.2.1) |
| 136 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. L.D. -2.5- Circular shape 450mm internal diameter(DSR-19.19.1.3) |
| 137 | SUPPLY OF BRICK BATTS FOR SOAK PIT DEDUCT IN CENTRAL CORE(MR) |
| 138 | LABOUR CHARGE FOR FILLING OF BRICK BATS(MR) |
| 139 | MS ANGEL IRON MANHOLE FRAME 60X60(DSR-10.25.1) |
| 140 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge.(300 MM DIA) Beyond 90 metre & upto 150 metre depth below ground level.(DSR-23.2.1.1) |
| 141 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge 150 mm nominal size dia(DSR-23.10.2) |
| 142 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge. 150 mm nominal size dia(DSR-23.11.2) |
| 143 | Development of tube well in accordance with IS : 2800 (part I) and IS:11189, to establish maximum rate of usable water yield without sandcontent (beyond permissible limit), with required capacity air compressor,running the compressor for required time till well is fully developed,measuring yield of well by “V” notch method or any other approved method,measuring static level & draw down etc. by step draw down method,collecting water samples & getting tested in approved laboratory, i/cdisinfection of tubewell, all complete, including hire & labour charges ofair compressor, tools & accessories etc., all as per requirement anddirection of Engineer-in-charge.(DSR-23.12) |
| 144 | Providing and fixing M.S. clamp of required dia to the top of casing/housingpipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts required size complete. 200 mm nominal size dia(DSR-23.14.2) |
| 145 | Providing and fixing C.I. sluice valve . 100 mm nominal bore. Class I(DSR-18.31.1.1) |
| 146 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (100 mm nominal dia Pipes ) Boring to building(DSR-18.9.7) |
| 147 | Supply of tubewell motar pump of 500 lit/min discharge w.h. of control panel, support wire etc. complete 5.00 to 7.5 H.P. (MR ) |
| 148 | Water supply tanker of 5000 litre capacity(DSR-7763) |
| 149 | Supply and fixing of nylon jali around the slotted pipescomplete as required. Up to 10 meter (MR) |
| 150 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge ,complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 35 sq. mm 3-1/2 core(MR) |
| 151 | Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches.(DSR-2.8.1) |
| 152 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand (zone-iii) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (R.C.C. work in Beam, Footing & Column), (R.C.C. WORK IN TIE BEAM), (R.C.C. WORK IN FOOTING), Raft Foundation(DSR-5.1.2) |
| 153 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work above the plinth Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (R.C.C. WORK IN Column & Top Band)(DSR-5.3) |
| 154 | Centering and shuttering including strutting, propping etc. and removal of form for: (b) Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick(DSR-5.9.21) |
| 155 | Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade 'A' sealing compound.(DSR-16.46.1) |
| 156 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. (DSR-16.78.3) |
| 157 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. DSR 16.91.2(DSR-16.91.2) |
| 158 | Add to item no. 1 for every additional lead of 30 mt. or part of 30mt and for every additional lift of 1.50mt. or part of 1.50 mt.(DSR-2.6.1+2.26.1) |
| 159 | Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. 3.00 to 4.50 mtr.(DSR-2.6.1+ 2.26.1*2 )) |
| 160 | Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. 4.50 to 6.00 mtr.(DSR-(2.6.1+ 2.26.1*3 )) |
| 161 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-30. As in item no. 6 above but for slabs (DSR-5.33.1.2) |
| 162 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 163 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.(DSR-10.31) |
| 164 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction withframe of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters : 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. (a) 35mm thick(DSR- 9.21.1+9.22.1*2) |
| 165 | Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm(DSR- 13.44.1) |
| 166 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete. (a) 250mm x 16mm(DSR- 9.62.1) |
| 167 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (a) 250 mm x 10mm (DSR- 9.63.1) |
| 168 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete. 125mm(DSR- 9.66.1) |
| 169 | Providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size)(DSR- 4.1.4) |
| 170 | Providing and fixing glass strips in joints of terrazo/ cement concrete floors.40 mm wide and 4 mm thic(DSR- 11.13.1) |
| 171 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm(DSR- 11.46.1) |
| 172 | Electric Work-Wiring for light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.(DSR-1.10.3 (Group-C)) |
| 173 | Wiring for fan point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.(DSR-1.10.3 (Group-C)) |
| 174 | Wiring for exhaust fan point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.(DSR-1.10.3 (Group-C)) |
| 175 | Wiring for call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.(DSR-1.10.3 (Group-C)) |
| 176 | Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.(DSR-1.11) |
| 177 | Wiring for circuit/ submain wiring along with earth wire 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.(DSR-1.14.1) |
| 178 | Wiring for circuit/ submain wiring along with earth wire 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.(DSR-1.14.2) |
| 179 | Wiring for circuit/ submain wiring along with earth wire 2 X 4 sq. mm + 1 X 4 sq. mm earth wire of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.(DSR-1.14.3) |
| 180 | Wiring for circuit/ submain wiring along with earth wire 2 X 6 sq. mm + 1 X 6 sq. mm earth wire of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.(DSR-1.14.4) |
| 181 | Wiring for circuit/ submain wiring along with earth wire 2 X 10 sq. mm + 1 X 6 sq. mm earth wire of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.(DSR-1.14.5) |
| 182 | Wiring for circuit/ submain wiring along with earth wire 2 X 16 sq. mm + 1 X 6 sq. mm earth wire of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.(DSR-1.14.6) |
| 183 | Providing and fixing circular/Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, to lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12mm dia M.S. bent to shape as per standard drawing. (DSR-Civil DSR. 10.18) |
| 184 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.(DSR-1.31) |
| 185 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.(DSR-1.32) |
| 186 | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required.(DSR-1.57) |
| 187 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.(DSR-1.38) |
| 188 | Installation, Testing and Commissioning of Upto 450 mm sweep exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.(DSR-1.50.1) |
| 189 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.(DSR-1.51) |
| 190 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required.(DSR-2.16) |
| 191 | Supplying and fixing 4 way (4 + 12), Double door horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).(DSR-2.4.1) |
| 192 | Supplying and fixing of 4 way (4 + 12), Double door surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)(DSR-2.5.1) |
| 193 | Providing and fixing 100 A,30KA,FPMCCB and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.(DSR-2.2.13) |
| 194 | Supplying and fixing 6way (4 + 18), Double door horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).(DSR-2.4.2) |
| 195 | Supplying and fixing 6 way , Double door single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)(DSR-2.3.1) |
| 196 | Supplying and fixing 8 way , Double door single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)(DSR-2.3.2) |
| 197 | Supplying and fixing 12 way , Double door single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)(DSR-2.3.3) |
| 198 | Supplying and fixing 5 A to 32 A rating, Single pole 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(DSR-2.10.1) |
| 199 | Supplying and fixing 5 A to 32 A rating, double pole 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(DSR-2.10.3) |
| 200 | Supplying and fixing 5 A to 32 A rating, Tripole and neutral 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(DSR-2.10.5) |
| 201 | Supply and fixing of 40 / 63 Amp. DP MCB(10KA) C Curve(DSR-Quot) |
| 202 | Supplying and fixing 40 Amp. 4Pole 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(DSR-Quota) |
| 203 | Supplying and fixing 63 Amp. 4Pole 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(DSR-Quota) |
| 204 | Supply and laying of one number PVC insulated and PVC sheathed/ XLPE Power Aluminium Cable of 1.1 KV Grade of 10 sqmm x 4 core on wall surface as required. (DSR-20c.1.8) |
| 205 | Supply and laying of one number PVC insulated and PVC sheathed/ XLPE Power Aluminium Cable of 1.1 KV Grade of 16 sqmm x 4 core on wall surface as required.(DSR-20c.1.9) |
| 206 | Supply and laying of one number PVC insulated and PVC sheathed/ XLPE Power Aluminium Cable of 1.1 KV Grade of 25 sqmm x 3-1/2 core on wall surface as required.(DSR-20c.1.10) |
| 207 | Supply and laying of one number PVC insulated and PVC sheathed/ XLPE Power Aluminium Cable of 1.1 KV Grade of 35 sqmm x 3-1/2 core on wall surface as required. (DSR-20c.1.11) |
| 208 | Supply and laying of one number PVC insulated and PVC sheathed/ XLPE Power Aluminium Cable of 1.1 KV Grade of 50 sqmm x 3-1/2 core on wall surface as required.(DSR-20c.1.12) |
| 209 | Supply and laying of 50 sqmm x 3-1/2 core Core aluminium conductor PVC insulated armoured served sheathed cables 1100 Volt grade at a depth of 750mm below ground level over a cushion of 75mm thick sand all around and protected with burned bricks on sides and on top as directed engineer in charge complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.(DSR-20a.1.12) |
| 210 | Supply and laying of 300 sqmm x 3-1/2 core Core aluminium conductor PVC insulated armoured served sheathed cables 1100 Volt grade at a depth of 750mm below ground level over a cushion of 75mm thick sand all around and protected with burned bricks on sides and on top as directed engineer in charge complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.(DSR-20a.1.19) |
| 211 | Supplying and making end termination with brass compression gland and aluminium lugs for 4 X 10 sq. mm (25mm) of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.(DSR-11.1.32) |
| 212 | Supplying and making end termination with brass compression gland and aluminium lugs for 4 X 16 sq. mm (28mm) of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.(DSR-11.1.33) |
| 213 | Supplying and making end termination with brass compression gland and aluminium lugs for 3½ X 25 sq. mm (28mm) of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.(DSR-11.1.20) |
| 214 | 3½ X 35 sq. mm (25mm) Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.(DSR-11.1.21) |
| 215 | Supplying and making end termination with brass compression gland and aluminium lugs for 3½ X 50sq. mm (35mm)of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.(DSR-11.1.22) |
| 216 | Supplying and making end termination with brass compression gland and aluminium lugs for3½ X 95 sq. mm (45mm) of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.(DSR-11.1.24) |
| 217 | Supplying and making end termination with brass compression gland and aluminium lugs for 3½ X 300 sq. mm (62mm) of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.(DSR-11.1.30) |
| 218 | Supply and Fixing of water tight oblong 10 Watt LED bulkhead luminaire having pressure die cast housing with driver set confirming to IP-65 and above protection IK08, high purity transitivity UV stabilized Non yellowish diffuser for unform light distribution, detachable driver set open and short circuit protection suitable for 24 Hr continuous operation complete in all respect. CAT-AAA 1200 System Lumens > 120Lm/W, PF>0.95, CRI > 70,>300V over voltage protection, 4 KV internal surge protection metal housing with 5 year warrantee.(DSR-PWD Circle SOR Item No.-23.11) |
| 219 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.(DSR-5.4) |
| 220 | Earthing with copper plate 600 mm X 600 mm X 3mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.(DSR-5.6) |
| 221 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.(DSR-5.1) |
| 222 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.(DSR-5.11) |
| 223 | Ligting arrester supply & fixing of level-1 tested accordance with NFC-17-102 for advance triggering time 22 micro seconds, temperature with stand test of -40 to +120 degree centigrate, CE marked, short circuit test for 100 KA etc, including following make - Liva/ESE (DSR-Quot.) |
| 224 | Ligting arrester SITC 5 GI mast with adaptor head and base plate for raising the lighting rod by 5 m abover the surface to proteceted including insulator between lighting.(DSR-Quot.) |
| 225 | Lighting arrester SITC copper cable 70 sqmm flexible copper single core multi strand.(Quot.) |
| 226 | Lighting arrester SITC 6 digits IP 67 ligting counter with hole for cable / strip LEC-D(Quot.) |
| 227 | Lighting arrester SITC earthing set (2 Nos.) consisting of copper bounder rod 17.2 mm dia 10 ft long 250 microns UL marked, 30 Kg earth enhancing chemical compound with resistivity of <0.1 Ohm-m NABl lab , tested, clamp for connecting rod to cable/strip including civil work with nit complete.(Quot.) |
| 228 | SITC stay wire, lugs, U clam, base plate fastner, hook fasteners, test link/clamp etc, As required complete.(Quot.) |
| 229 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.(DSR-5.16) |
| 230 | Add for invertor wiring in wiring point for light/fan/plug points complete.(8+2+6= 16 Nos. for each residence). (Quot) |
| 231 | Supply of fresh air Fan 300 mm. Make-Crompton and equivalent.(Quot) |
| 232 | Supplying and fixing brass batten/ angle holder including connection etc. as required.(DSR-1.34) |
| 233 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.(DSR-1.26) |
| 234 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required.(DSR-2.21) |
| 235 | Supply and laying of 1800mm x 900mm x 12mm thick chequered rubber matting of tested quality.(Quot.) |
| 236 | Supplying and installaton 450 mm width X 62.5 mm depth X 2.0 mm thickness of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastener etc as required.(DSR-4.1.10) |
| 237 | SITC of LT panel vermin proof mounting , M.S. channel base with bottom and fabricated out of 2.0/1.6mm thick CRCA sheet steel, painted with powder coated paint of shade as per the direction of Engineer in charge after proper sheet treatment process of sheet steel. The bus bar of panel shall be of electrical grade high conductive aluminium alloy of appropriate cross-section as per ratin the main bus bar shall run throughout the panel of rating as main incomer rating. The bus bar shall be supported by non hygroscopic SMC/DMC bus bar supports which shall be mounted on proper interval to ensure the bear the jerks of short circuit of 50kA for panels having ACB as incomer & 36kA for panels having MCCB incomers panel shall be constructed in fully segregated comparment design for each feeder as per 3b construction fonnat the panel shall be completed in all respect as per IS: 8623 part-2&3 . There shall be seprated metering compartment for incommer metering and outgoing metering.All incommer feeders shall be provided with multifunctioning metering along with phase indicating lights and other associated components such as CT, control MCB terminal block etc. and all outgoing feeders 100A and above shall be provided with 3 phase ammeter along with phase indicating lights and other associated components such instruments shall be digital type and indicating lights shall be LED type. wiring shall be done from 1100V grid PVC insulated copper flexible wire. All ACB shall be electrically operated draw out type with all MCCB shall be thermal agnetic/microprocessor with O/L & S/C protection along with required spreaders & extended rotary handle with pad locking facility of Breaking capacity (ICU/ICS) 36KA or more all MCB shall be thermal 10KA 'C' Curve cubicle type switch board shall be category A and B only. Incoming: 630Amp. MCCB 1 No., Outgoing: 200 Amp. MCCB-2 Nos.,100 Amp. MCCB-2 Nos.,63 Amp. MCCB-1Nos. (DSR-20.1.4(c) (ii)) |
| 238 | Supply and fixing of IP 20 , front lid , mid power SMD type LED light , recess /surface mounting round 10-15 watt , cutout minimum 150 mm heigt 40 mm, LED down lighter having powder coated die cast aluminium housing with heat sink high purity/transmisivity UV stablised non yellowish diffuser/reflector for uniform light distribution detachable driver set suitable for 24 hour countinous operation complete in all respect. 2160-2400 system lumen > 120 lm/watt PF> .95 THD is < 10% at full load . CRI > 80, >300 volt over voltage protection 2.5 KV internal surge protection with 5 year warranty. CAT AAA(DSR-PWD SOR no. 23.02) |
| 239 | Supply of 10 Watt LED Bulb Philips Make and equivalent.(Quot) |
| 240 | Supply and Fixing of Computer Board including 2 Nos. 3 Pin 5/6 A modular socket outlet and 5/6 A Modular switch and 1 No. 6 Pin 5/6 & 15/16 A modular socket outlet and 15/16 A Modular switch and 12 module size, G.I. box along with modular base and cover plate for modular switch in recess etc as required. (DSR-1.24.1+1.24.4+1.24.3+1.24.5+1.27.6) |
| 241 | LED Batten light (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of 18-22 Watt LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protectionof 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life nds, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing / Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS /HFFR, PVC insulated copper conductor single corecable and earthing etc. as required with Minimum 5 yearOEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) (DSR-8.10.1) |
| 242 | Supply, Installation, Testing and Commissioning of 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. steel/Al body Power Factor not less than 0.9, Service Value(DSR-9.2.3) |
| 243 | Supply and Fixing of Single LED LIght Wall Bracket complete in all respect. (Quot.) |
| 244 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt)Supplying, installation, Testing & Commissioning of 90 watt Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report,CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not riseabove 90°C).(DSR-8.13.14) |
| 245 | (DSR-Plint area rate 4.1.4) Supplying, Installation, Testing & Commissioning of following capacity passenger Machine room less (MRL) lift with regenerative drive as per CPWD General Specification for Electrical Works (Part-III Lift & Escalator) 2003, BIS Codes, NBC 2016 as amended upto date having provision for barrier free access as per Harmonised Guidelines & Standards for Universal Accessibility in India - 2021 of MoHUA, serving different floors in the lift shaft as per detailed specifications enclosed and as under including all other equipment and accessories complete as required:-(i) Speed-1.5 MPS(ii) Floors-6 (G+5)(iii) Travel -27 Meters (approx.)(iv) Stops & opening- 5 stops and 5 openings(v) Controller: A.C. variable voltage & variablefrequency(vi) Automatic rescue device (ARD) complete with drymaintenance free batteries as required.vii) Operation: Microprocessor based single automaticpush button/simplex selective collective/duplexcollective selective with/without attendant(viii) Power-415 Volts+10%, 3 phase, 50 Hz, 4 wiressystem(ix) Car Enclosure: Stainless steel scratch proof (MoonRock/Honeycomb/ Hairline Finish) on all sides andstainless steel decorative ceiling with fans (indirectthrow) and LED fitting.(x) The car flooring should be smooth and antiskid asapproved by engineer-in-charge. (xi) Type of doors announce the position of the elevator in the hoist way as the car passes or stops at floor served by the elevator.(xiv) Closed loop Control System, protection against power fluctuation, self diagnostic control, Landing doors 2 hours Fire rated, Overload detection and protection, Overspeed Governer, Dot Matrix LED D & P Indicators In Car & Landings, BMS Compatibility, tamper proof infrared curtain covering almost the entire height of the lift car door, Alarm horn, AntiNuisance Operation, CCTV camera system with 4 MPIP camera, suitable NVR and HDD for 30 days storage backup , Firemen switch, 2/3 way intercom, Emergency Stop Switch with battery backup for fan and light fitting for 1 hour, pit ladder. (xv) The lift doors shall have a vision panel to enablepersons with hearing impairment tosignal for help or assistance in the event of anemergency. (xvi) An appropriate technological support be provided (Through emergency messaging |services or alarms etc.) to respond to the emergency requirements of person with hearing impairment or deafness. (xvii) In case of failure of ARD or other electronic devices, a provision of manual rescue be provided(a) Car: Power operated, centre opening horizontal sliding stainless steel scratch proof (Moon Rock/Honeycomb/ airline Finish). (b) Landing doors: stainless steel scratch proof .(xii) A hand rail not less that 600mm long at 900mm above floor level to be fixed adjacent to control panel in the lift car. (xiii) Voice announcement system in the car to(DSR-Plint area rate 4.1.4) |
| 246 | Supply of fresh air Fan 300 mm. Make-Havells and equivalent.(Quot.) |
| 247 | Extra for Fixing the Louvers/ Shutters Complete with Frame for Exhaust Fan of all sizes.(DSR-1.51) |
| 248 | (DSR-29.1.6) Supplying, Installation, Testing & Commissioning of 82.5 KVA ‘Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Rating of 82.5 KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications, should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location, rating plate as per relevant ISCode etc. and consisting of the followings: (A) Diesel Engine:Tourbocharged Diesel engine 4 stroke water cooled, multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 0C, 50% RH & at 1000 Meter MSL , capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV + or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as per CPWD specifications.(B) Engine mounted Instrument Panel fitted with and having digital dis Plate for following:(i) Start-stop switch with key(ii) Water temperature indication(iii) Lubrication oil pressure indication(iv) Lubrication oil temperature indication(v) Battery charging indication and Voltage indication(vi) RPM indication(vii) Over speed indication(viii) Low lubricantion Oil trip indication(ix) Engine Running Hours indication(x) Fuel Level (C) Alternator: Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 0C, 50% RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of continuous operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation.(D) Base Frame & Foundation: Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer.(E) FUEL TANK: Daily service fuel tank of suitable liters capacity as per CPWD Specifications, fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications.(F) Exhaust System: Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor.(G) Starting System: 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180 AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set.(H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable connection/connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof & dust-proof conforming to IP-65 protection. The enclosure shall be as per CPCB IV + or better norms etc. and as per CPWD specifications. (I) AMF Panel: Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, suitable for KVA as below for silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase & Total), KW & provision for overload, short circuit, restricted earth fault, under frequency, power (aluminium) and control (copper ) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as required, all complete and inter locking and communication/ Ethernet /RS485/SNMP port open protocol for BMS integration including suitable software, the panel shall be of DG Set OEM make etc. as per approved by Engineering in charge and including the following: 1. Suitable numbers and appropriate capacity 4 pole motorised electrically operated draw out with cradle type 3 position ACB/ MCCB with electronic release for O/C & E/F and shunt trip.2. Auto/Manual/Test/Off selector switch3. Protection for under and over voltage phase reversal (2 nos Over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay).4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering5. Energy analyser unit to indicate current, Voltage( LN & L_L), kW, kVA (Phase & Total), Frequency, KWH, PF.6. LED Indicating lamps for load on mains and load on set7. Fuse/ MCB for instruments8. Battery charger, complete with transformer/ rectifier, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.9. Main supply failure monitor10. Supply failure timer11. Restoration timer12. Control unit with three impulse automatic enginestart/stop and failure to start lockout.13. Impulse counter with locking and reset facility.14. ON/OFF/Control circuit switch with indicator15. Audio/Video annunciation for(i) High water temperature(ii) Low lubricating oil pressure(iii) Engine over speed(iv) Engine fails to start(v) Full load/maximum load warning 16. Protection for over/under Frequency, Loss of AC sensing, Over Current, Unbalancing load with suitable number of relays and accessories17. Maintenance notification based on Engine Run Hour & due date.18. Load Management through PLC to achieve auto opening and closing of incomer breakers, bus coupler switching of essential panel , interlocking providing signal to AMF Panel for load status and AMF shall give command to DG Set to auto start / auto stop depending upon load status and requirement etc. and necessary hardware and software required to perform the operation shall be provided by the contractor including all control wiring.(DSR-29.1.6) |
| 249 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.(DSR-5.4) |
| 250 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.(DSR-5.11) |
| 251 | Supply and laying of 95 sqmm x 3-1/2 core Core aluminium conductor PVC insulated armoured served sheathed cables 1100 Volt grade at a depth of 750mm below ground level over a cushion of 75mm thick sand all around and protected with burned bricks on sides and on top as directed engineer in charge complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.(DSR-20a.1.14) |
| 252 | Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarmpanel, central processing unit with the Ten Loop Panel. modules and capable of supporting not less than 240devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5 % V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger.The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications.(DSR-28.2.1.1) |
| 253 | Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.(DSR-28.2.4) |
| 254 | Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed temperature thermistor complete with base as required.(DSR-28.2.9) |
| 255 | Supplying, installation, testing & commissioning of addressable fire control module complete as required.(DSR-28.2.10) |
| 256 | Supplying, installation, testing & commissioning of addressable manual call point complete as required.(DSR-28.2.14) |
| 257 | Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.(DSR-28.2.15) |
| 258 | Supplying, installation, testing & commissioning of fault isolator complete with base as required.(DSR-28.2.7) |
| 259 | Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED,metallic cover complete with all connections etc as required(DSR-28.2.5) |
| 260 | Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required(DSR-28.2.3) |
| 261 | Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.(DSR-28.5.1) |
| 262 | Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required.(DSR-28.5.4) |
| 263 | Supply and fixing of 25mm of steel conduit along with the accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required:(DSR-1.20.2) |
| 264 | Providing laying, testing & commissioning of 150 mm. Dia 'C' class heavy duty MS Pipe conforming to IS 1239/Class -II of IS: 3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete asrequired.(DSR-27.6.2) |
| 265 | Providing laying, testing & commissioning of 200 mm. Dia 'C' class heavy duty MS Pipe conforming to IS 1239/Class -II of IS: 3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required.(DSR-27.6.1) |
| 266 | Providing, laying, testing & commissioning of 25 mm. dia. 'C' class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :(DSR-27.7.1) |
| 267 | Providing, laying, testing & commissioning of 32 mm. dia. 'C' class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :(DSR-27.7.2) |
| 268 | Providing, laying, testing & commissioning of 40 mm. dia. 'C' class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :(DSR-27.7.3) |
| 269 | Providing, laying, testing & commissioning of 50 mm. dia. 'C' class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :(DSR-27.7.4) |
| 270 | Providing, laying, testing & commissioning of 80 mm. dia. 'C' class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :(DSR-27.7.6) |
| 271 | Providing, laying, testing & commissioning of 100 mm. dia. 'C' class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :(DSR-27.7.7) |
| 272 | Supplying and fixing Single headed Stainless steel external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required :(DSR-27.10.2) |
| 273 | Supplying, fixing, testing and commissioning of 40 mm dia butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :(DSR-27.11.1) |
| 274 | Supplying, fixing, testing and commissioning of 50 mm dia butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :(DSR-27.11.2) |
| 275 | Supplying, fixing, testing and commissioning of 80 mm dia butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :(DSR-27.11.4) |
| 276 | Supplying, fixing, testing and commissioning of 100 mm dia butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :(DSR-27.11.5) |
| 277 | Providing, installation, testing and commissioning of 100 mm dia. non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :(DSR-27.14.5) |
| 278 | Providing, installation, testing and commissioning of 150 mm dia. non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :(DSR-27.14.7) |
| 279 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :(DSR-27.16.2) |
| 280 | Supplying and fixing first-aid Hose Reel 30 mtr. with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.(a) 20 mm nominal internal dia water hosethermoplastic (Textile reinforced) type -2 as per IS: 12585(b) 20 mm nominal internal dia gun metal globe valve & nozzle.(c) Drum and brackets for fixing the equipmets on wall.(d) Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.(DSR-27.17.1) |
| 281 | Supplying & fixing 63 mm dia gun metal Stainless Steel (Grade 304) short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required:(DSR-27.18.2) |
| 282 | Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.(DSR-27.13) |
| 283 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required.(DSR-27.2) |
| 284 | Supplying & fixing single headed stainless steel internal yard hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel, ISI marked, confirming to IS 5290(type A) with blank Gunmetal/Stainless Steel cap and chain as required:(DSR-27.9.2) |
| 285 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.(DSR-27.22) |
| 286 | Provinding & fixing carbon steel Fire Man Axe with rubber insulated handle tested to 20000 volts.(Quot.) |
| 287 | Provinding & fixing of 1.6 mm thick M.S. Hose Box/ Frame Door capable of accommodating fire Landing Valve Hose Pipes fitting & accessories The door shall have a front glass with lock and key arrangement & shall be painted with post office red colour(approval shall be taken on the basis of submitted sample before ordering) cost of fire extinguisher not included in item rate.( Liasioing with civil contractor box(by civil contractor)(Quot.) |
| 288 | SITC of cast iron Ball Valve 25mm dia.(Quot.) |
| 289 | Supply and fixing of self illuminating glow exit signage Size 400x150 mm. (Quot.) |
| 290 | Supply and fixing of fire extinguisher CO2 type 4.5 kg capacity (ISI marked IS: 2878 & TAC approved) complete with intial charge and wall braket along with supply of all material and labour for proper completion of work.(Quot.) |
| 291 | Supply and fixing of fire extinguisher ABC type 4 kg capacity (ISI marked IS: 15683 & TAC approved) complete with intial charge and wall braket along with supply of all material and labour for proper completion of work.(Quot.) |
| 292 | Supplying and fixing of 2 way - 100 mm dia M.S. Pipe fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required:(DSR-27.19.1) |
| 293 | Supplying and fixing of 4 way - 150 mm dia M.S. Pipe fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required:(DSR-27.19.2) |
| 294 | SPRINKLER - Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 0C with required accessories :(DSR-27.21.)Pendent Sprinkler(DSR-27.21.1) |
| 295 | Providing, installation, testing and commission of adjustable rosette plate for 15mm dia in white finish UL listed or FM approved complete as required.(DSR-27.29) |
| 296 | Supplying, installation, testing & commissioning of 1000mm sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required(DSR-27.25.2) |
| 297 | Providing & fixing flow switch in 100 mm dia M.S.pipe including connection etc as required.(DSR-27.23.1) |
| 298 | Providing, fixing, testing & commissioning of installation control valve of 100mm dia cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required:(DSR-27.24.2.) |
| 299 | FIRE PUMP SET:- (A) Supplying, installation, testing and commissioning of Electric driven Main Fire Pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required(B)Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal as required.(C) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-12615: 2018.(D)M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required(E) Suitable cement concrete foundation duly plastered with anti vibration pads.2280 LPM AT 56 M HEAD(DSR-27.1.6) |
| 300 | (a) Supplying, installation, testing andcommissioning of diesel engine driven main firepump conforming to IS 12469: 2019 suitable forautomatic operation and consisting of following,complete in all respects, as required : (Diesel DrivenPump)(b) Horizontal type, multistage, centrifugal pump ofcast of iron body and bronze impeller with stainlesssteel shaft, mechanical seal as required.(c)Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.(d) M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.(e)Suitable cement concrete foundation duly plastered and with anti vibration pads.2280 LPM AT 56 M HEAD(DSR-27.2.6) |
| 301 | (a) Supplying, installation, testing and commissioning of electric driven pressurisation pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required : (JockeyPump)(b) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainles steel shaft, mechanical seal as required.(c) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class- 'F' insulation, conforming to IS-12615: 2018.(d) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (e) Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 56 m Head(DSR-27.3.3) |
| 302 | Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors,dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required:(DSR-27.5.1)INCOMING -250A, 50KA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector swtich & CTs etc.LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300AOUTGOING-Main Fire Pump-125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operationOUTGOING-Jockey Pump 63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. DIESEL ENGINE CONTROL-Control for diesel engine comprising - Automatic/Manual selctor switch & 3 attemptsstarting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter All standard relays and accessories for automaticoperation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification |
| 303 | (A) Supplying, installation, testing and commissioning of 450 lpm at 35 m Head electric driven terrace pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (DSR-27.4.2)(B) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal as required.(C )Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class- 'F' insulation, conforming to IS-12615: 2018.(D) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.( E) Suitable cement concrete foundation duly plastered and with anti vibration pads. |
| 304 | Providing, laying, testing & commissioning of 150 mm. dia. 'C' class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :(DSR-27.7.8) |
| 305 | Providing, laying, testing & commissioning of 200 mm.(wall thickness 6.3mm) dia. 'C' class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :(DSR-27.7.9) |
| 306 | Supplying, fixing, testing and commissioning of 80 mm dia butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :(DSR-27.11.4) |
| 307 | Supplying, fixing, testing and commissioning of 100 mm dia butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :(DSR-27.11.5) |
| 308 | Supplying, fixing, testing and commissioning of 150 mm dia butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :(DSR-27.11.6) |
| 309 | Supplying, fixing, testing and commissioning of 200 mm dia butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :(DSR-27.11.7) |
| 310 | Providing, installation, testing and commissioning of 150 mm dia. non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :(DSR-27.14.7) |
| 311 | Providing, installation, testing and commissioning of 200 mm dia. non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :(DSR-27.14.8) |
| 312 | Providing, installation, testing and commission of 200 mm dia stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel(grade 304) sheet with 3 mm dia holes with stainless steel flange.(DSR-27.15.4) |
| 313 | Providing and fixing in position the industrial type Pressure Gauges with gun metal / brass valves complete as required(DSR-30.8) |
| 314 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.(DSR-27.22) |
| 315 | Providing, fixing, testing & commissioning of installation 150mm dia control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required:(DSR-27.24.3) |
| 316 | Supply and fixing of fire extinguisher ABC type 4 kg capacity (ISI marked IS: 15683 & TAC approved) complete with intial charge and wall braket along with supply of all material and labour for proper completion of work.(Quot.) |
| 317 | SITC of Draw of connection for fire Brigade.(Quot.) |
| 318 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.(DSR-5.6) |
| 319 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.(DSR-5.14) |
| 320 | Supply and laying of 25 Sq. mm. 3-1/2 Core aluminium conductor PVC insulated armoured served sheathed cables 1100 Volt grade at a depth of 750 mm. Below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run sell be fixed on M.S. clamps etc. of suitable size or as directed by engineer incharge complete in all respect including excavation and refilling. The armouring of the cable sell be properly connected with the earth conductor by clamps etc. (DSR-Approved by 47th (E/M) circle 20.1.10) |
| 321 | Supplying and making end termination with brass compression gland and aluminium lugs for 3½ X 25 sq. mm (28mm) of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.(DSR-11.1.20) |
| 322 | Providing and fixing M.V. danger notice plate 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. (DSR-2.21) |
| 323 | Wiring for light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.(DSR-1.1.3 (Group-C)) |
| 324 | Wiring for fan point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.(DSR-1.1.3 (Group-C)) |
| 325 | Wiring for exhaust fan point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.(DSR-1.1.3 (Group-C)) |
| 326 | Supplying and Fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 Pin 5/6 A modular socket outlet and 5/6 A Modular switch, connection etc. as required.(DSR-1.31) |
| 327 | Supplying and Fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 Pin 5/6 & 15/16 A modular socket outlet and 15/16 A Modular switch, connection etc. as required.(DSR-1.32) |
| 328 | Installation of exhaust fan up to 450 mm. sweep in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.(DSR-1.50.1) |
| 329 | Extra for Fixing the Louvers/ Shutters Complete with Frame for Exhaust Fan of all sizes.(DSR-1.51) |
| 330 | Supply, Installation, Testing and Commissioning of 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.(DSR-9.2.3) |
| 331 | Wiring for circuit/ submain wiring along with earth wire with the 2 x 1.5 Sq. mm. + 1 x 1.5 Sq. mm earth wire earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ reccessed medium class PVC conduit as required. (DSR-1.14.1) |
| 332 | Wiring for circuit/ submain wiring along with earth wire with the 2 x 2.5 Sqmm + 1 x 2.5 Sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ reccessed medium class PVC conduit as required.(DSR-1.14.2) |
| 333 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ reccessed medium class PVC conduit as required for 4 x 10 Sq. mm + 2 x 6 Sq. mm earth wire(DSR-1.14.10) |
| 334 | Supply and Fixing of 5A To 32A rating Single Pole 240/415V, 10ka, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc, as required.(DSR-2.10.1) |
| 335 | Supply and Fixing of 63 Amp 4Pole MCB (10KA) C Curve in the existing MCB DB complete with connection, testing and commissioning etc, as required. (Quot.) |
| 336 | Supplying and Fixing 4 Way (4+12), Double Door Horizontal Type Three Pole and Neutral, Sheet Steel, MCB Distribution Board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).(DSR-2.4.1) |
| 337 | LED Batten light (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of LED 18- 22 Watt surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard DeviationColour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. completein all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per equirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not riseabove 90°C). Powder coated die cast /Extruded aluminiumBody (Thickness > 1.20 mm) (DSR-8.10.1) |
| 338 | Supply of fresh air Fan 300 mm. Make-Havells and equivalent.(Quot.) |
| 339 | Supply and Fixing of 16 SWG M.S. drum duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respect. (Quot.) |
| 340 | Supply and laying of 1800mm x 900mm x 12mm thick chequered rubber matting of lested quality(Quot.) |
| 341 | Supply and fixing of Fire bucket (4Nos +Stand)(Quot.) |
| 342 | Providing, laying and fixing 100 mm dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required(DSR-15.13.3) |
| 343 | Provinding & fixing cast iron air release valve of 25 mm dia including 25 mm dia ball valve with fittings etc. as per the requirement.(Quot.) |
| 344 | SITC of Automatic control Panel of Terrace Pump suitable for 5 H.P. terrace pump(Quot.) |
| 345 | Supply and laying of 95 sqmm x 3-1/2 core Core aluminium conductor PVC insulated armoured served sheathed cables 1100 Volt grade at a depth of 750mm below ground level over a cushion of 75mm thick sand all around and protected with burned bricks on sides and on top as directed engineer in charge complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.(DSR-20a.1.14) |
| 346 | Supply and fixing of 7 mtr. G.I. octagonal pole of approved make (top dia 70mm, bottom dia 130 mm & base plae 12mm thick) having 3mm, thickness with single arm baracket length of 1 mtr. Lengrg id 1 mtr. Length in 1:2:4 RCC foundation bolt including the cost of foundation , excavation & back filling and required T & P complete in all respect.(DSR-21.2) |
| 347 | LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt)Supplying, installation, Testing & Commissioning of 90 watt Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report,CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not riseabove 90°C).(DSR-8.13.14) |
| 348 | Supply and laying of 6sq. mm 4 Core aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. (DSR-20a.1.7) |
| 349 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.(DSR-5.4) |
| 350 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)(DSR-5.9) |
| 351 | Wiring for circuit/ submain wiring along with earth wire 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.(DSR-1.14.2) |
| 352 | Supplying and fixing 5 A to 32 A rating, double pole 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(DSR-2.10.3) |
| 353 | S/F of heavy duty cadmium plated copper connector with end plated 40 Amp 4-way complete P.S. N0. -1128C(Quot) |
| 354 | Supplying, Installation, Testing and commissioning of Astronomical time switch of 3 output(1output per phase) and suitable for three phase supply configuration to be mounted in feeder pillars / Lighting DBs for automatic switching On & OFF of street lights at sun set & sun rise or twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site complete as required.(DSR-7.4.3) Note - 1- Rates are inclusive of all taxes but excluding GST which shall be paid extra as applicable. Rate of BoQ 5% Less Competitive price efficiency 2- BoQ Rate Excluding Labour cess. Labour Cess will be added & deducted from contractor's bill at the time of payment Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy