| 1 | Taking down the unserviceable point wiring of lights, fans, sockets complete including switches, switch sockets outlets, fan regulators, lamp holder, ceiling rose, etc. excluding light fittings and depositing where directed and making good the disturbed surfaces to match with the existing surface complete all as specified and as directed. |
| 2 | Taking down the existing unserviceable MCB DB along with MCBs of any type and capacity and depositing where directed and making good the disturbed surface to match with the existing surface complete all as specified and as directed. |
| 3 | M & L for Point wiring complete with 1.5 sqmm FRLSH single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor drawn through and including non-metallic rigid PVC conduit PVC conduit fittings and conduit accessories concealed in walls, roofs and floors etc., including Modular flush boxes and Modular cover plates for switches concealed in walls, roof and socket/ electronics fan regulator/ telephone socket, including provision of 1.5 sqmm PVC insulated unsheathed cable with multi stranded copper conductor as earth continuity conductor and connecting to common earth dolly all as specified for one light/ fan point controlled by one way switch complete including cutting chases, pinning in, making good to facing where required and pointing in cement mortar 1:3 for concealed conduit wiring and making good the disturbed surfaces, matching with the existing wall surfaces, cutting not exceeding 10 Cm girth complete all as specified and as directed. |
| 4 | One light point controlled by one switch |
| 5 | One fan point controlled by one switch and one regulator |
| 6 | One 3 pin 5 Amps switch socket on independent board |
| 7 | One 3 pin 5 amps switch socket on same board along with other switches. |
| 8 | One bell point controlled by bell push switch on independent board. |
| 9 | All as per item No.3 here in before but with 4 Sqmm single core PVC cable for one 3 pin 15 amps switch socket outlet on independent board. |
| 10 | M & L for sub main wiring with PVC insulated, 1100 volts grade single core FRLSH multistranded copper conductor cable conforming to IS specifications, 2 runs of 10 sqmm including one run of 10 sqmm single core multistranded copper conductor PVC insulated cables as earth continuity conductor with colour code drawn through and including one run of 25mm dia rigid PVC conduit and conduit accessories or casing capping including accessories fixed on wall/ceiling etc., or concealed in wall and connecting to common earth dolly including taking down old unserviceable complete all as specified and as directed. |
| 11 | All as per item No.4 here in above but with 2 runs of 6 Sqmm and one run of 1 x 6 sqmm earth wire in PVC conduit complete all as specified and as directed. |
| 12 | All as per item No.4 here in above but with 2 runs of 4 Sqmm and one run of 1 x 4 sqmm earth wire in PVC conduit complete all as specified and as directed. |
| 13 | All as per item No.4 here in above but with 2 x 2.5 sqmm + 1 x 2.5 sqmm earth wire in PVC conduit complete all as specified and as directed. |
| 14 | All as per item No.4 here in above but with 2 x 1.5 sqmm + 1 x 1.5 sqmm earth wire in PVC conduit complete all as specified and as directed.Note for item No.4 to 8:- Three runs of wire and one run of conduit will be measured as one \\"RM\\" Unit. |
| 15 | All as per item No.4 here in above but with 4 runs of 10 sqmm and one run of 1 x 10 sqmm earth wire in PVC conduit complete all as specified and as directed.Note for item Nos 4 to 9:-(a) The wiring shall be done in proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.(b) For concealed wiring wherever required cutting chases will be measured separately under relevant items.Note for item No.9:- 5 runs of wire and one run of conduit will be measured as one \\"RM\\" Unit. |
| 16 | S & F Ceiling rose surface Bakelite 65mm x 50mm three terminals complete all as specified and as directed. |
| 17 | S & F in repairs Switch piano flush type 5 amps single pole, one way, 240 Volts complete all as specified and as directed. |
| 18 | S & F in repairs Switch socket outlet 3 pin, 5 amp, flush type complete all as specified and as directed. |
| 19 | S & F in repairs Socket outlet 3 pin 5 Amps flush type complete all as specified and as directed. |
| 20 | S & F in repairs Bell push flush type 5 amps single pole 240 Volts complete all as specified and as directed. |
| 21 | S & F in repairs Buzzer, AC, 230 volts, single pole complete all as specified and as directed. |
| 22 | S & F in repairs Bell ding dong, AC, 230 volts, single pole complete all as specified and as directed. |
| 23 | S & F in repairs Socket outlet 3 pin 15 amps flush type complete all as specified and as directed. |
| 24 | S & F in repairs Switch socket outlet multipurpose 3 pin, 15 amp and one pin, 5 amp controlled by one switch complete all as specified and as directed. |
| 25 | S & F in repairs stepped type electronic fan regulator flush type on the exiting phenolic laminated sheet extra as required complete all as specified and as directed. |
| 26 | S & F in repairs Modular Switch Roma flush DIRECT TO FIT press type 10 amps single pole, one way, 240 Volts all as per site requirement complete all as specified and as directed. |
| 27 | S & F in repairs Modular Switch Roma flush DIRECT TO FIT press type 16/20 amps single pole, one way, 240 Volts all as per site requirement complete all as specified and as directed. |
| 28 | S & F in repairs Modular Socket Roma flush DIRECT TO FIT press type 10 amps single pole, 240 Volts all as per site requirement complete all as specified and as directed. |
| 29 | S & F in repairs Modular Socket Roma flush DIRECT TO FIT press type 16/20 amps single pole,240 Volts all as per site requirement complete all as specified and as directed. |
| 30 | S & F in repairs Lamp holder insulated body complete all as specified and as directed. |
| 31 | S & F in repairs Modular Fan step regulator, 120W - 1 module for ceiling Fan of 1200 mm sweep complete all as specified and as directed. |
| 32 | S & F in repairs Modular white cover with plate with frame 2 module including suitable flush box, matching with white cement work if necessary complete all as specified and as directed. |
| 33 | S & F in repairs Modular white cover with plate with frame 3 module including suitable flush box, matching with white cement work if necessary complete all as specified and as directed |
| 34 | S & F in repairs Modular white cover with plate with frame 4 module including suitable flush box, matching with white cement work if necessary complete all as specified and as directed |
| 35 | S & F in repairs Modular white cover with plate with frame 6 module including suitable flush box, matching with white cement work if necessary complete all as specified and as directed |
| 36 | S & F in repairs Modular white cover with plate with frame 8 module including suitable flush box, matching with white cement work if necessary complete all as specified and as directed |
| 37 | S & F in repairs Modular white cover with plate with frame 12 module including suitable flush box, matching with white cement work if necessary complete all as specified and as directed |
| 38 | S & F in repairs Modular white cover with plate with frame 16 module including suitable flush box, matching with white cement work if necessary complete all as specified and as directed |
| 39 | S & F replacement of metal clad socket single pole and neutral enclosure with a two pin and earth plug top and socket complete with one single pole MCB 230 Volts 20/32 Amps complete all as specified and as directed. |
| 40 | S & F replacement of single phase existing Metal clad plug and socket complete all as specified and as directed. |
| 41 | S & F in repairs MCCB Distribution board, TP&N, vertical, double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link,415 Volts 4 way fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete including 4 Pole V-Tec MCCB of 100 A rating & 16kA breaking capacity, MCCB pre-fitted at factory complete all as specified and as directed. |
| 42 | S & F in repairs MCCB Distribution board, TP&N, vertical , double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 415 Volts 8 way fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete including 4 Pole V-Tec MCCB of 100 A rating & 16kA breaking capacity, MCCB pre-fitted at factory complete all as specified and as directed. |
| 43 | S & F in repairs MCCB Distribution board, TP&N, vertical , double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link,415 Volts 12 way fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete including 4 Pole V-Tec MCCB of 160A rating & 16kA breaking capacity, MCCB pre-fitted at factory complete all as specified and as directed. |
| 44 | S & F in repairs MCCB four pole, 415 Volt, 100 Amps, 16KA, adjustable thermal & fixed magnetic setting complete all as specified and as directed. |
| 45 | S & F in repairs MCCB four pole, 415 Volt, 125 Amps, 16KA, adjustable thermal & fixed magnetic setting complete all as specified and as directed. |
| 46 | S & F in repairs MCCB four pole, 415 Volt, 160 Amps, 16 KA, adjustable thermal & fixed magnetic setting complete all as specified and as directed. |
| 47 | S & F in repairs MCB TPN Distribution board, 415 volts Triple pole and neutral, double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 4 ways Double door, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and as directed. |
| 48 | S & F in repairs MCB Distribution board, 240 volts single pole and neutral, double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 4 ways SPN Double door, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and as directed. |
| 49 | S & F in repairs MCB Distribution board, 240 volts single pole and neutral, double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 8 ways SPN Double door, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and as directed. |
| 50 | S & F in repairs MCB Distribution board, 240 volts single pole and neutral, double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 12 ways SPN Double door, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and as directed. |
| 51 | S & F in repairs MCB SP, 240 Volt,6-32 Amps, 10 kA rupturing capacity 'C' series complete all as specified and directed including taking down old one complete all as specified and as directed. |
| 52 | S & F in repairs MCB SPN, 240 Volts, 32 Amps, 10 kA rupturing capacity 'C' series complete all as specified and directed including taking down old one complete all as specified and as directed. |
| 53 | S & F in repairs MCB TP 415 volts, 6-32 amps 'C' Curve 10 kA Capacity complete all as specified and as directed. |
| 54 | S & F in repairs MCB TP 415 volts, 63 amps 'C' Curve 10 kA Capacity complete all as specified and as directed. |
| 55 | S & F in repairs MCB TPN 415 volts, 6-32 amps 'C' Curve 10 kA Capacity complete all as specified and as directed. |
| 56 | S & F in repairs MCB TPN 415 volts, 63 amps 'C' Curve 10 kA Capacity complete all as specified and as directed. |
| 57 | S & F in repairs 40W LED Extruded Aluminium LED batten (4 ft) for surface and pendant applications lighting fixture with high lumen output, environmental friendly, energy efficient complete all as specified and as directed. |
| 58 | S & F in repairs 20W LED Engineering plastic batten with white acrylic cover sleek design & high efficiency for wall & surface mounted applications. Lighting fixture with high lumen output, environmental friendly, energy efficient complete all as specified and as directed. |
| 59 | S & F in repairs 10W LED Engineering plastic batten with white acrylic cover sleek design & high efficiency for wall & surface mounted applications. Lighting fixture with high lumen output, environmental friendly, energy efficient complete all as specified and as directed. |
| 60 | S & F in repairs 36W LED Surface mounted powder coated CRCA housing 2ft x 2ft luminaire providing uniform illumination. Suitable for all kind of open office applications. lighting fixture with high lumen output, environmental friendly, energy efficient complete all as specified and as directed. |
| 61 | S & F in repairs 36W LED Recess mounted powder coated CRCA housing 2ft x 2ft luminaire providing uniform illumination Suitable for all kind of open office applications lighting fixture with high lumen output, environmental friendly, energy efficient complete all as specified and as directed. |
| 62 | S & F in repairs 30W LED Nexo range of Low & Mid power LED street light comes with single piece IP66 pressure die cast housing and secondary lens delivering 120 lm/W, making it suitable for various applications ranging form a campus light to city lights with high lumen output, environmental friendly, energy efficient complete all as specified and as directed. |
| 63 | S & F in repairs Bulk head fitting 10W Environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge-lit LED luminaire comprising of high brightness LED complete all as specified and as directed. |
| 64 | Taking down ceiling fans/Exhaust/wall fan of any size, any make make, model, dismantling blades for repair/servicing /replacement of parts/rewinding and refixing the same after replacement of spares and parts servicing/ rewinding complete all as specified and as directed.Note:- spare parts and rewinding and servicing shall be measured separately as Supply Only |
| 65 | Ball bearing for ceiling fan/Exhaust fan/Wall fan/Pedestal fan upto 1400mm sweep. |
| 66 | Bush bearing for ceiling fan/Exhaust fan/Wall fan/Pedestal fan upto 1400mm sweep. |
| 67 | Fan condenser capacitor 2.5 mfd. |
| 68 | Down rod 15 mm dia medium grade including cutting required length, drilling holes, painting complete. |
| 69 | Fan blade of existing model/Make/Type for upto 1400 mm sweep |
| 70 | Shaft assembly including lath works complete for ceiling fan/ Exhaust fan/ Wall fan/Pedestal fan upto 1400mm sweep |
| 71 | M & L for Copper winding of ceiling Fan and Exhaust Fan wire suitable gauge as per OEM Recommendation. |
| 72 | Labour only for attending and identifying electric supply complaints no lights and day to day maintenance of existing switch board, DB's, meter box, building security lights and building LT Panels including connecting electrical accessories/ spares of elect supply installations, electrical fitting with lights, short circuits in any OTM/Md accn/ Pump house as per complaint register complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 73 | Labour only for attending and identifying electric supply complaints no lights and day to day maintenance of existing switch board, DB's, meter box, building security lights and building LT Panels including connecting electrical accessories/ spares of elect supply installations, electrical fitting with lights, short circuits in any OTM/Md accn/ Pump house as per complaint register complete all as specified and as directed. Please Enable Macros to View BoQ information |