Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | construction of kusti hall building related works |
| 2 | Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. |
| 3 | Filling of Carted earth. |
| 4 | Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete,including cost of form- work, in foundation and floors. |
| 5 | Sand filling in plinth under floors including watering, ramming, consolidating and dressing complete including lead up to 50m and lift upto 1.5m and including cost of sand. |
| 6 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm |
| 7 | (4) Treatment junction of wall and the floor 7.5 liters /sqm (5)Treatment of soil along external perimeter of building 7.5 liters/sqm. (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution) |
| 8 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete . Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 9 | Footing |
| 10 | Column |
| 11 | All works above plinth level upto floor V level M-25 |
| 12 | (For R.C.C. Lintel) |
| 13 | Ground Floor |
| 14 | Mumty |
| 15 | (For R.C.C. Slab) |
| 16 | Ground Floor |
| 17 | Mumty |
| 18 | (For R.C.C. Beam) |
| 19 | Ground Floor |
| 20 | Mumty |
| 21 | (For R.C.C. Column) |
| 22 | Ground Floor |
| 23 | Mumty |
| 24 | Class M-150 brick work in 1:6 cement coarse sand (of 2.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour, tools and plants etc. required for proper completion of the work. |
| 25 | Brick work in 1:6 cement coarse sand in super-structure above plinth level up to floor two level ( up to two storeys ) including necessary cutting and moulding of brick work as required and also including honeycombed brick work in thickness of wall more than 12cms. |
| 26 | Ground Floor |
| 27 | Mumty |
| 28 | Same as in item no. 16 but in 1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. |
| 29 | Ground Floor |
| 30 | Mumty |
| 31 | Providing & fixing ISI marked flush door shutters conforming IS: 2202 decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters (a) 35mm thick including ISI marked stainless steel butt hinges with necessary screws. & both side laminated. |
| 32 | Single leaf |
| 33 | Double leaf |
| 34 | Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. |
| 35 | Providing & fixing of hold fast for chaukhats |
| 36 | of doors and windows. |
| 37 | Providing & fixing of door / windows grill. |
| 38 | Z- Section fixed |
| 39 | Angle iron door chaukhats 40X40X5 |
| 40 | Cement concrete 1:2:4 (1 cement:2 coarse sand :4 graded stone aggregate 20mm nominal size including supply of all materials, labour and T & P etc required for proper completion of the work and curing complete also including cost of formwork in foundation and floors. |
| 41 | Fe-500 Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 42 | All works upto plinth level |
| 43 | All works above plinth level |
| 44 | Ground Floor |
| 45 | Mumty |
| 46 | 15 mm cement plaster on rough side of single or half brick wall of mix:. (1) 1 cement : 4 Coarse sand. |
| 47 | 12 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand f.m.-2.25 |
| 48 | Ground Floor |
| 49 | Mumty |
| 50 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand f.m.-2.25 |
| 51 | Ground Floor |
| 52 | Mumty |
| 53 | Making grooves 10 to 12mm wide x 8mm deep in plaster of the wall or in ceiling vertically or horizontally as required. |
| 54 | Ground Floor |
| 55 | Mumty |
| 56 | Supply and fixing of 6mm (1/4\\") thick china white glazed tile in flooring or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement jointed and polishing complete including supply of all materials, labour for proper complition of work. (anti skis / matt finished) |
| 57 | Ground Floor |
| 58 | Supply and fixing of 6mm (1/4\\") thick china white glazed tile in flooring or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement jointed and polishing complete including supply of all materials, labour for proper complition of work. (anti skis / matt finished) Ground Floor |
| 59 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.(Size of tile 600 x 600 mm) (anti skis / matt finished) Ground Floor |
| 60 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.(Size of tile 600 x 600 mm) (anti skis / matt finished) Ground Floor |
| 61 | Kota stone slab flooring over 25 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick. Ground Floor |
| 62 | Painting or varnishing work in small areas or new wood work with one coat upto one square metre of ready mixed priming paint and one coat of approed superior quality ready mixed paint or varnish including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. Paint to be used should fonfirm the ISI no. 103-1950 (M.S. works) |
| 63 | Painting or varnishing work in small areas or new wood work with one coat upto one square metre of ready mixed priming paint and one coat of approed superior quality ready mixed paint or varnish including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. Paint to be used should fonfirm the ISI no. 103-1950 (Wood work) |
| 64 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (Inner + Ceiling) |
| 65 | Ground Floor |
| 66 | Mumty |
| 67 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). |
| 68 | Ground Floor |
| 69 | Mumty |
| 70 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 71 | Ground Floor |
| 72 | Mumty |
| 73 | Providing & fixing Brass sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm. |
| 74 | 250mm*10mm |
| 75 | 200mm*10mm |
| 76 | Providing and fixing bright finished brass tower bolts (barrel type)with necessary screws etc. complete |
| 77 | (a) 200 mm x 10mm |
| 78 | Providing and fixing bright finished brass handles with screws etc. complete. |
| 79 | (a) 125mm |
| 80 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete |
| 81 | Providing and fixing aluminium extruded section body tubular typeuniversal hydraulic door closer (having brand logo with ISI, IS : 3564,embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
| 82 | P/F curtain rods of 1.25mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs etc. wherever necessary complete (a) 25 mm dia. |
| 83 | S/O Hnad rail and balustrade modular systom passive SS-304 grade decorative railling system comprising of hand rail 50mm thick and 3 No.hortzontal steel pipe of 19mm dia and 1.5mm thick of equal spacing with balustrade of SS pipe of 38mm and 1.5mm thick @ 1200 mm C/C of passivated SS 304 rade and fix duly on the floor with spacially rivet expansion bolt and finish the surface food and covering with steel shope with all visible stainless metal of 304 grade in satin finsh hight of ralling is 900mm as per detailed specification. |
| 84 | Providing and fixing 12mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer in charge (Door handle, lock and stopper etc. to be paid separately) |
| 85 | Providing and fixing water closet squatting pan ( Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS:7231, Parryware/Hindware/Seabird/Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required. |
| 86 | White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests |
| 87 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever), conforming to IS : 7231, Parryware/Hindware/Seabrid /Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : |
| 88 | Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15 mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standerd pattern including cutting & making good the walls wherever required. |
| 89 | a)White Vitreous China Flat back wash Basin size 550x400 mm with single 15 mm C.P. brass pillar tap. |
| 90 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe |
| 91 | 32 mm dia |
| 92 | 40 mm dia |
| 93 | Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 94 | Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : |
| 95 | Kitchen sink with drain board |
| 96 | 610x510 mm bowl depth 200 mm |
| 97 | Providing and fixing unplasticised PVC connection pipe with brass unions 45 cm length 15 mm nominal bore |
| 98 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 a) 15 mm nominal bore |
| 99 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 400 gms. a) 15 mm nominal bore |
| 100 | Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931 |
| 101 | a) 15 mm nominal bore |
| 102 | Providing and fixing C.P. brass shower rose with 15 or 20mm inlet 150 mm diameter |
| 103 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931: 15mm nominal bore |
| 104 | Providing & fixing soil, waste and vent pipes. |
| 105 | a) 100mm dia centrifugally cast iron S & S pipe. |
| 106 | b) 75mm dia centrifugally cast iron S & S pipe. |
| 107 | Providing and fixing centrifugaly cast iron single equal plain junction of required degree. |
| 108 | 100x100x100mm |
| 109 | 75x75x75mm |
| 110 | Providing and fixing cast iron terminal guard. |
| 111 | 100 mm |
| 112 | 75 mm |
| 113 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. 110 mm |
| 114 | Providing and fixing on wall face unplasticised PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion. |
| 115 | 110 mm Bend |
| 116 | Shoe (Plain) 110 mm Shoe |
| 117 | Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm |
| 118 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. |
| 119 | Providing and fixing GI pipes complete with GI fittings and clamps, including cutting and making good walls etc. (internal work). |
| 120 | Internal work-Exposed on wall |
| 121 | 15mm dia nominal bore |
| 122 | 20mm dia nominal bore |
| 123 | 25mm dia nominal bore |
| 124 | 32mm dia nominal bore |
| 125 | Providing and fixing GI Union in GI pipes including cutting and threading the pipe and making long screws etc. complete (new work). |
| 126 | 15mm dia nominal bore |
| 127 | 20mm dia nominal bore |
| 128 | 25mm dia nominal bore |
| 129 | 32mm dia nominal bore |
| 130 | 40mm dia nominal bore |
| 131 | Providing and fixing gun metal gate valve with wheel of approved quality. |
| 132 | 25mm dia nominal bore |
| 133 | 32mm dia nominal bore |
| 134 | 40mm dia nominal bore |
| 135 | Providing and fixing brass stop cock of approved quality. |
| 136 | a) 15 mm nominal bore |
| 137 | b) 20 mm nominal bore |
| 138 | Providing and placing on terrace (at all floor levels)polyethylene water storage tank ISI : 12701 marked indicating the BIS License No. with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fitting and base support for tank.[Sintex, Electroplast, Star, Lotus or equivalent having valid ISI license]. |
| 139 | Capcity in Per Liters |
| 140 | Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50mAll kinds of soil |
| 141 | Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm. |
| 142 | Providing, laying and jointing glazed stoneware pipes grade 'A' with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 coarse sand) including testing of joints etc. complete. |
| 143 | 100mm diameter |
| 144 | 150mm diameter |
| 145 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) all round S.W. pipes including bed concrete as per standard design |
| 146 | 100mm dia SW pipe |
| 147 | 150mm dia SW pipe |
| 148 | Providing and fixing square-mouth S.W. gully trap grade‘A’ complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 150 x 100 mm size P type |
| 149 | With Sewer bricks conforming to IS : 4885 |
| 150 | Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg).CLASS-M150 BRICKS |
| 151 | (i) For Sewer Line |
| 152 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not lessthan 190 gms. |
| 153 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms |
| 154 | Extra for providing & fixing 125 mm dia C.P. grating in place of C.I. grating over floor traps. |
| 155 | Providing and Fixing C.P. brass Ablution health faucet assembly with 1.2 m long braided PVC hose with mounting bracket fixed on wall complete.[FOR EWC] |
| 156 | Providing and fixing C.P. brass Two-way angle valve for EWC points & for fixing Ablution Health Fauct of approved quality conforming to IS:8931. 15 mm nominal bore |
| 157 | Providing & fixing Jaquar make C.P. brass bottle trap. |
| 158 | Providing and fixing G.I Inlet fitting with 2 inlets 75 mm size fabricated from 100 mm dia G.I pipes(approx. length=150mm to 300mm) and welded G.I sockets, fixed to CI trap with lead caulked joint and set in cement concrete as per standard drawing including cost of Bitumastic paint complete. |
| 159 | Wiring point for light with 1.5 sq. mm.FRLSH PVCinsulated multistrand single core copper conductor cable in heavy guage rigid steel conduit pipe partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, complete with 14 SWG copper earth continuity wire,GP Box, piano type switch & ceiling rose/angle/batten holder on 3mm thick phenolic paminated backalite sheet etc complete in all respect as directed including matching colour wash. |
| 160 | Same as in item 138 (B) but in PVC conduit with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside. |
| 161 | Add for light / fan points with modular type switch in place of piano type switch. |
| 162 | Wiring point for two ways light with 1.5 sq. mm. F.R. PVC insulated multistrand single core copper conductor cable in heavy guage rigid steel conduit pipe partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, complete with 14 SWG copper earth continuity wire , GP Box and two number two way piano type switches & ceiling rose / angle / batten holder on 3 mm thick phanolic laminated backelite sheet etc., complete in all respect, as directed, including matching colour wash. |
| 163 | Same as in item 139(B)but in PVC conduit with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit. |
| 164 | Add for 2 way light point with modular switches in place of piano type switches. |
| 165 | Wiring point for fan / fresh air fan (light duty exhaust fan) with 1.5 sq.mm.FRLSH PVC insulated multistrand single core copper conductor cable in heavy guage rigid steel conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with 14 SWG copper earth continuity wire,GP Box , piano type switch & ceiling rose on 3 mm. thick backelite sheet etc., complete in all respect including matching colour wash |
| 166 | Same as in item 140 (B) but in PVC conduit with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit |
| 167 | Add for light /fan points with modular type switch in place of piano type switch |
| 168 | Wiring points for Plug with 1.5 sqmm.FR PVC insulated multistrand single core copper condutor cable in heavy guage rigid PVC conduit pipe partly concealed in the wall and partly laid in slab along with the reinforcement before concreting, complete with 14 SWG copper earth contunity wire,piano type switch & socket sheet etc.complete in all respects.as directed including matching colour wash. |
| 169 | Add for plug point with modular switch & socket in place of piano type switches |
| 170 | Wiring point for call bell with 1.5 sq. mm.FRLSH PVCinsulated multistrand single core copper conductor cable in heavy guage rigid steel conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting complete with 14 SWG copper earth continuity wire GP Box and piano type bell push or 2 pin socket etc, complete in all respect including matching colour wash. |
| 171 | Same as in item 142 (B) but in PVC conduit with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit. |
| 172 | Add for Call bell point with modular type bell push in piano type bell push |
| 173 | Wiring point for exhaust fan with 1.5 sq. mm.FRLSHPVC insulated multistrand single core copper conductor cable in heavy guage rigid steel conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with 14 SWG copper earth continuity wire,GP Box , 15A piano type switch & ceiling rose on 3 mm thick phenolic laminated backelite sheet etc., complete in all respect including matching colour wash. |
| 174 | Same as in item 144 (B) but in PVC conduit with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit. |
| 175 | Add for light /fan points with modular type switch in place of piano type switch |
| 176 | Supply and wiring of 4 number 10 Sq.mm.FR PVC insulated 1100 V grade Multistrand single core copper conductor cable in 32 mm heavy guage rigid pvcl conduit pipe partly concealed in wall and partly laid in slab along with reinforcement before concreting, with two number 10 SWG copper earth continuity wire including colour wash etc. complete in all respects. |
| 177 | As in item no. 278 (B) but in heavy duty (2 mm thick) PVC conduit with 2 nos 6 sq.mm. FRLSH PVC insulated copper conductor cable as earth continuity wire drawn in conduit. |
| 178 | Supply and wiring of submains with 2 nos. 2.5 sq mm & with 1 no earth wire of 1.5 sq mm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cable in existing PVC conduit complete, including supply of all material, labour and T & P etc. required for proper completion of the work as directed by Engineer in charge. |
| 179 | Same as in item 291 but with 2 nos. 4 sq mm and 1 no 2.5 sq mm FRLSH PVC insulated copper conductor cable. |
| 180 | Supply and wiring of submain with two number 1.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy guage rigid steel conduit partly laid in slab alongwith reinforcement before concreting and partly concealed in wall, with one no. 14 SWG copper earth continuity wire etc, complete in all respects including matching colour wash. |
| 181 | As in item no.1313(B) but in 20 mm dia heavy duty (2mm thick) PVC conduit with 1 nos. 1.5 sq. mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable as earth continuity wire drawn inside the conduit complete in all respect. |
| 182 | Supply and wiring of 4 number 16 sq. mm. PVC insulated 1100 V grade single core Copper conductor cable in 40 mm dia PVC conduit partly concealed in wall and partly laid in slab alongwith reinforcement before concreting, with two number 10 sq mm single core Copper conductor cable as earth continuity wiredrawn in coudit including matching colour wash etc, complete in all respect. |
| 183 | Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire |
| 184 | 25 sq. mm 3-1/2 core |
| 185 | 70sqmm 3.5 core |
| 186 | Supplying and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge. |
| 187 | 25 sqmm |
| 188 | 70 sqmm |
| 189 | Supply & fixing of Crimping, solder, less, copper ton electroplated lugs of Dowel/ismail make suitable for 1.5 sqmm to 6sqmm cables, including tapping with insulating tape, etc. complete in all respects. |
| 190 | Supply and fixing and concealing of 20 mm dia. 2mm thick PVC conduit pipe with ISI mark embossed and with PVC accessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin / adhesive to make the complete piping rigid, plastering with cement sand mortar finished to the level with matching colour wash including cost of all material labour and T&P etc required for proper completion of the work as per directions and to the satisfaction of Engineer in charge. |
| 191 | Same as in item 148 (A) but 25 mm dia 2 mm thick PVC conduit. |
| 192 | Same as in item 148 (A) but 32 mm dia. PVC conduit. |
| 193 | Same as in item 148 A, but 50 mm dia (2.0 mm) thick PVC conduit. |
| 194 | Supply and fixing of 2/3/4 ways round PVC junction box confirming to ISS for 20mm dia PVC conduit concealed in wall, keeping its level upto plaster duly provided with proper size cover, screwed as directed at site by the Engineer I/C with supply of all the material, labour and T&P required for proper completion of work. |
| 195 | Same as in item 154 (A) but for 25 mm dia. PVC conduit. |
| 196 | Same as in item 154 (A) but for 32 mm dia. PVC conduit. |
| 197 | Same as in item 154 but for 50 mm dia 2.0 mm thick P V C conduit. |
| 198 | Supply and fixing of G.P. Modular switch box for 1 / 2 Module of approved make made up of 1.0 mm thick ISI Marked G.P.sheet including adjestable Nakka and holes plugged with PVC Nylon Caps . Two or more holes for pipe entry of 25.4 mm on upper and lower sides of the box. Holes should be semi-shuttered type and fitted with heavy brass Earth Piller duly screwed & brand name should be embossed. Box flushed in wall including cutting of brick work, fixing it to the level with cement sand mortar, including matching colour wash with s/o all materials, labour and T&P required for proper completion of work as directed at site by the Engineer in charge. |
| 199 | Same as in item no 1152 (A) but for 3 Module |
| 200 | Same as in item no 1152 (A) but for 4 Module |
| 201 | Same as in item no 1152 (A) but for 6 Module |
| 202 | Same as in item no 1152 (A) but for 8 Module |
| 203 | SSame as in item no 1152 (A) but for 12 Module |
| 204 | Supply and fixing hexagonal/Round G.P.fan box of approved make made up of 1.0 mm thick ISI Marked G.P.sheet spot welded Four to Eight holes of 25.4 mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwed fitted with 300 mm round zink coted M.S Bar X 12 mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work. |
| 205 | Supply and fixing of G.P. Boxes/Housing for Conceaded LED / CFL Lamps 335 mm wide x 63.5 mm deep(2.5\\")of approved make made up of 1.0 mm thick ISI Marked G.P.sheet spot welded Four to Eight holes for pipe entry of 25.4 mm of the box. Holes should be semi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwed & brand name should be empossed. Including all materials, labour and T&P required for proper completion of work as directed at site by the Engineer in charge. |
| 206 | S/f of 340 mm wide x 76.2 mm deep(3.0\\")G.P.Box/Housing) |
| 207 | S/f of 340 mm wide x 101.6 mm deep(3.0\\")G.P.Box/Housing) |
| 208 | Construction of recess of 480mm x 480mm x 200mm size for fixing of main boards, distribution boards of all sizes including cutting of brick work, providing lintel of suitable size and thickness, plastering etc. with supply of all materials labour T&P for proper completion of work. |
| 209 | Supply & fixing of Recess mounting round 15 to 18 watt LED Down Lighter having powder coated die cast aluminium housing with heat sink diffuser /reflector and driver set complete in all respect . |
| 210 | Cat. AAA |
| 211 | Supply & fixing of LED Tube Light with batten suitable for up to 1x22 watt Led tube light fitting including tube Suraface complete in all respect. |
| 212 | Cat. AA |
| 213 | Supply & fixing of LED Tube Light with batten suitable for up to 2x22 watt Led tube light fitting including tube Suraface complete in all respect. |
| 214 | Cat. AAA |
| 215 | S&F and making connection of 63 Amp. 4 pole 30mA ELCB/RCCB of Din Rail Mounting complete in all respect as per direction and satisfaction to the Engineer in charge. |
| 216 | Supply and fixing of 6 Amp to 32 Amp . SPMCB (10 KA) C Curve |
| 217 | CAT B |
| 218 | 40 Amp. 4 POLE MCB (10 KA) |
| 219 | CAT A |
| 220 | 63 Amp. 4 POLE MCB 10 KA C CURVE |
| 221 | CAT A |
| 222 | Supply and fixing of surface/ flush mounting VTPN distribution board with additional metal board without MCB complete in all respect, as directed at site by Engineer Incharge. |
| 223 | 8Way TPN |
| 224 | CAT A |
| 225 | 12Way TPN |
| 226 | CAT A |
| 227 | Supply and fixing Single Pole MCBS Blanking Plate complete in all respects. |
| 228 | CAT A |
| 229 | Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. down rod 19mm dia duly painted, complete in all respects. |
| 230 | Erection and testing exhaust fan on the existing hole with suitable size of rag bolts nuts and washers etc. complete in all respects. |
| 231 | Supply & fixing of 16 gauge M.S.drum duly painted including making hole in the wall for exhaust fan and finishing properly etc. complete as required. |
| 232 | Supply and fixing of electronic fan regulator 120-280V. ISI marked, on the existing switch board including making connections, required material, labour T&P etc. for proper completion of work to the satisfaction of Engineer in charge of work. |
| 233 | Supply and fixing of power plug with 20 Amp./250 volt flush type modular switch and 5 pin 20 A/250 volt flush type universal modular socket switch on concealed M.S box including supply of all material, labour T&P etc. required for proper completion of work. |
| 234 | Supply and erection of factory fabricated and wired metal clad dust and vermin proof floor mounting panel TPN switch board complete with the following HRC type heavy duty |
| 235 | TPN fuse switches with fuses and instrument chamber etc. complete in all respects. The instrument chamber shall beseparate and shall comprise of flush type ammeter, voltmerer, selector switches for ammeter and voltmeter, instrument fuses, |
| 236 | current transormer etc. The board shall have suitable capacity electroytic alumininum busbars as per IS8623 istulate with heat shrink sleeving and mountend on non hygroscopic supports such as CMC/DMC support with deteachable side covers and shall be suitable for extension on the sides. |
| 237 | The switches shall be complete with suitable cable end boxes, reverse entery boxes in case of pedestaal type, cable sockets, compression glands and indicating lamp on incoming etc. |
| 238 | The job includes the grounting of the board as per direction of Engineer-in-Charge. All coutgoing switches of 100 Amp. and above will be provided with ampere metre current transformers and selector switches and instrument fuses etc. The switches board shall be fabricated with CRCA sheet with a minimum thickness of 1.6 mm/2 mm. Cubicle type switch board shall be of cat A B & B-II and pedestal type for Cat-B and C only. |
| 239 | Incoming |
| 240 | 200 Amp. TPN-1 No |
| 241 | Outgoing |
| 242 | 100 Amp. TPN-1 No and 63 Amp. TPN-3 Nos. |
| 243 | Cat. B. Cubicle Type |
| 244 | Supply and erection of AC 1400mm Sweep, 230/250 Volts, 60 Hz ceilling fan with regulater standar down rod, blades including connection etc. complete as required |
| 245 | Bajaj Grace Gold Dx 1200mm Bianco ceiling fan |
| 246 | Supply and erection of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required |
| 247 | Bajaj Freshee Exhaust Fan |
| 248 | COST OF SEWERAGE WORKS |
| 249 | Excavating trenches in all kinds of soil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m. |
| 250 | Pipes 80 mm to 300 mm diameter |
| 251 | Open timbering in trenches including shuttering and shoring complete. (Measurement to be taken of the face area timbered) |
| 252 | Depth not exceeding 1.5 meter |
| 253 | Providing and laying Non pressure NP 2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. |
| 254 | 150 mm. dia. RCC Pipes |
| 255 | Providing and laying cement concrete 1:5:10(1cement:5coarse sand :10 graded stone aggregate 40mm nominal size) upto the haunches of pipes including bed concrete as per standard design |
| 256 | 150 mm. dia. |
| 257 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. |
| 258 | Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). |
| 259 | Class M-150 |
| 260 | for sewer line |
| 261 | Extra for depth for manholes: |
| 262 | Size 90x80cm with M-150 Bricks |
| 263 | Providing orange colour safety foot rests of minimum 6 mm thick plastic encapsulated as per IS:10910 on 12 mm dia steel bar conforming to IS:1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm thread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. |
| 264 | COST OF EXTERNAL WATER SUPPLY WORKS providing and fixing G I pipes complete with G I fittings including trenching and refilling etc |
| 265 | 40mm nominal bore. |
| 266 | 32mm nominal bore. |
| 267 | Supplying and fixing of specials for pressure pipe. 10% of itme 2 &3 |
| 268 | Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. |
| 269 | 40mm nominal bore. |
| 270 | Excavation in Foundation in ordinary soil (Loam clay, or sand) including lift upto 1.5 metre (5 fts.) and lead upto 30m (100 fts) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-in-charge upto a distance of 30 m. (100 fts) from the foundation trenches. (Rate is including Royality). |
| 271 | 0.00m to 1.50 m |
| 272 | 1.50m to 3.00 m |
| 273 | Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete,including cost of form- work, in foundation and floors. |
| 274 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-200. |
| 275 | As in item no. 3 above but for slabs (Using 1:1.5:3 Mix concrete) |
| 276 | M-150 brick work in 1:4 (one cement and four coarse sand sand of 2.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. |
| 277 | Fe-500 Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 278 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor). |
| 279 | 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand) |
| 280 | Providing and fixing soil, waste and vent pipes : 75mm diameter : Sand cast iron S&S pipe as per IS: 1729 |
| 281 | Providing M.S. foot rests including fixing in manoholes with 20x20x10 cm cement concrete blocks 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as per standard design:(With 20x20mm square bar) |
| 282 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 283 | Supply & fixing of fire extinguishers, ABC type 4.00 Kg capacity (ISI marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 284 | Supply & fixing of fire extinguishers, CO2 type 4.50 Kg capacity (ISI marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 285 | TUBEWELL BORING WITH PUMP |
| 286 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge.(300mm dia) |
| 287 | Upto 90 metre depth below ground level. |
| 288 | Supplying, assembling, lowering and fixing in vertical position in bore well,unplasticized PVC medium well casing (CM) pipe of required dia,conforming to IS: 12818, including required hire and labour charges, fittings& accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. |
| 289 | 150 mm nominal size dia |
| 290 | Supplying, assembling, lowering and fixing in vertical position in bore wellunplasticized PVC medium well screen (RMS) pipes with ribs, conformingto IS: 12818, including hire & labour charges, fittings & accessories etc.all complete, for all depths, as per direction of Engineer-in-charge. |
| 291 | 150 mm nominal size dia |
| 292 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mmto 2 mm in recharge pit, in required thickness over gravel layer, for all leads& lifts, all complete as per direction of Engineer -in-charge. |
| 293 | Development of tube well in accordance with IS : 2800 (part I) and IS:11189, to establish maximum rate of usable water yield without sandcontent (beyond permissible limit), with required capacity air compressor,running the compressor for required time till well is fully developed,measuring yield of well by “V” notch method or any other approved method,measuring static level & draw down etc. by step draw down method,collecting water samples & getting tested in approved laboratory, i/cdisinfection of tubewell, all complete, including hire & labour charges ofair compressor, tools & accessories etc., all as per requirement anddirection of Engineer-in-charge. |
| 294 | Providing and fixing M.S. clamp of required dia to the top of casing/housingpipe of tubewell as per IS: 2800 (part I), including necessary bolts & nutsf required size complete. |
| 295 | 200 mm nominal size dia |
| 296 | Providing and fixing Bail plug /Bottam plug of required dia to the bottam of pipe assembly of tubewell as per IS:2800 (PART-1) 150 mm nominal size dia |
| 297 | 100 mm nominal bore. Class I |
| 298 | Providing and fixing G.I. pipes complete with G.I. fittings including trenchingand refilling etc.Submerssible to OHT |
| 299 | 80 mm dia nominal bore |
| 300 | Supply of Submersibule pump with control panel, support wire etc. complete 1.5 H.P. (KSB / EQ.) |
| 301 | Water supply tanker of 5000 litre capacity |
| 302 | Supply and fixing of nylon jali around the slotted pipescomplete as required. Up to 10 meter |
| 303 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge ,complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. |
| 304 | 35 sq. mm 3-1/2 core |
| 305 | Construction of cc road as per specification as per dpr and instruction of EIC with all labour material T&P etc complete |
| 306 | Construction of drain 300mm*450mm as per specification as per dpr and instruction of EIC with all labour material T&P etc complete Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy