| 1 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil : |
| 2 | Supply and filling of dry stone soling in foundation trenches/under floors tightly hand packed with hand ramming, dressing ,watering incld. carriage of material from source to site of work complete |
| 3 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 4 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 5 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 6 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) |
| 7 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m |
| 8 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete at all levels, Thermo-Mechanically Treated bars of grade Fe-500D or more, including all carriages. |
| 9 | Centering and shuttering including strutting propping etc. and removal of form for foundation, footings basses of columns etc . For mass concrete including all carriages. |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams,plinth beams, girders, bressumers and cantilevers including all carriages. |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for suspended floors, roofs, landings, balconies and access platforms. including all carriages. |
| 12 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in Cement mortar 1:6 ( 1 cement : 6 coarse sand) with Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level |
| 13 | 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 6 ( 1 cement : 6 fine sand) |
| 14 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete 2 mm thick |
| 15 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20 mm nominal size stone aggregate. |
| 16 | Providing wood work in frames of doors, windows, clesrestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately) imported KD wood including all carriages |
| 17 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows using 3.5mm thick float glasss panes including ISI marked M.S presseed Butt hinges bright finished of required size with necessary screews of KD wood. |
| 18 | Providing and fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with 4.0mm thick glass panes |
| 19 | Distempering with dry distemper of approved brand and manufacture (two or more coats) and of required shade on new work, over and including water thinnable priming coat to give an even shade |
| 20 | Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm) |
| 21 | Providing and fixing ISI marked oxidized M.S. tower bolt black finish, (Barrel type) with necessary screws etc complete 100x10 mm |
| 22 | 150x10 mm |
| 23 | Providing and fixing ISI marked oxidized M.S. handles conforming to IS : 4992 with necessary screws etc. complete 100 mm |
| 24 | 125mm |
| 25 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed torequired colour or shade with nuts and screws etc. complete 250x16 mm |
| 26 | Structural steel work welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete, including all carriages. |
| 27 | Providing & fixing colour coated (Hi-Rib) G.I sheet roofing 0.50mm thick incl. vertical/curved surface fixed with polymer coated J or L hooks bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I limpet washer and over lapping of sheets complete in horizontal vertical trusses incl. cutting to size and shape wherever required including Ridges or Hips of 60 cm overall width colour coated sheets 0.50mm thick and valleys of 90 cm width colour coated sheets 0.50mm thick etc complete as per the directions of Incharge Engineer. including all carriages. |
| 28 | Applying priming coat With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) including all carriages. |
| 29 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on new work including all carriages. |
| 30 | Providing and fixing of PVC concealed electric conduits of specified thickness (minimum 2mm) with necessary bends , TEEs , crosses, junction Boxes for lighting/ fan points etc of approved make & made including all necessary fittings (25mm dia). including carriage of materials involved complete. |
| 31 | Providing and commisioning lighting points incld wiring for lighting points in 1.5 Sq.mm PVC insulated copper wire and 2.5 Sqmm PVC insulated multi-strand copper wire for lighting sub mains,6 amp 1 way switch,2 mm thick PVC conduit/Channel with bends,junction boxes etc ,6 amp S Pole MCB ,10 amp DP MCB,2 way DB for housing MCB and hylem sheet of ISI mark and approved make with wooden box recessed in wallls with acessories incld all carriages (concelead type 12 watt) |
| 32 | Providing and commissioning heating point incld wiring for heating points in 2 .5 sq.mm PVC insulated multi-strand copper wire and 4 sq.mm PVC insulated multi-strand copper wire for heating sub-mains, 16 AMP switch socket combine,,2 mm thick PVC conduit/Channel with bends, Junction boxes etc , 10 Amp S pole MCB ,2 way DB for housing MCB and hylem sheet of ISI mark and approved make with wooden box recessed in /over wallls with acessories complete incld all carriages |
| 33 | Providing and commissioning of fan point incld wiring for lighting points in 1.5 sqmm PVC insulated multi strand copper wire,1200 mm ceiling fan /225 mm exhaust fan with ceiling roses and PVC square block ,350 watt electronic fan dimmer, 2 mm thick PVC conduit/Channel with bends, Junction boxes etc, 6 mm S pole MCB ,10 amp DP MCB , 2 way DB for housing MCB for lighting circuits and hylam sheet of ISI mark and approved make with wooden box recessed in wallls with acessories complete incld all carriage and costs of Fan and all other material involved. |
| 34 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete, , including all carriages. Size of tile 600x600 mm |
| 35 | Providing and laying gang saw cut of specified thickness, mirror polished pre- moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge. 18 mm thick |
| 36 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates andsimilar works. |
| 37 | Carriage of material by Mechanical transport from nearest approved source to site of Work Sand avg.lead-10 kms |
| 38 | Agg avg.lead-10 kms |
| 39 | Bricks for an avg lead of 65KMs Please Enable Macros to View BoQ information |