| 1 | Demolition of Brick/ stone / boulder masonry built in cement morter complete all as specified and directed . |
| 2 | Material and labour for brickwork with subclass designation 75 , old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified & directed. |
| 3 | Taking down cement plaster on brick /stone wall surface including raking out joints, hacking for keys, scrubbing down with water, etc. complete all as specified and as directed . |
| 4 | Material and Labour for rendering 15mm thick in cement mortar (1:4) on brick work or concrete surfaces and surfaces finished even and fair complete all as specified and directed |
| 5 | Material and labour for applying two coats of exterior acrylic emulsion paint of any shade in camouflage pattern over a coat of primer as approved by GE on new plastered surfaces of walls at height n. exc 10 m from average ground level (including scaffolding if required) for any bldgs/structures and the like etc including preparation of new plastered surfaces complete all as specified and directed. |
| 6 | Dismantling structural steel work including doors , gates etc complete all as speciified and as directed . |
| 7 | Supply and fix rolled mild steel Fe-290 (grade E-165) framed work as in doors or gates of angle or other section with gusset plate , rails , braces etc complete drilled for fixing of steel sheeting or other covering . Doors etc to be prepared for hanging or sliding with and including either hook and hinges or steel hanging door fittings complete all as specified and as directed . |
| 8 | Dismantling post or struts of RCC, Steel or other section, including taking out embedded portion in concrete and making good disturbed ground complete all as specified and as directed |
| 9 | Material and labour for plain Cement Concrete 1:4:8 type D2 using 40mm graded stone aggregate in foundation filling around the fencing post, complete all as specified and directed. |
| 10 | S&F mild steel angle iron as in fencing posts and struts including cutting tops to shape as directed drilling holes notching of wire etc flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or revieting, welding at corners etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. |
| 11 | M&L for dismentling galvanized, 2 strand,steel barbed wire 2.24mm dia complete all as specified directed |
| 12 | Supply only Chain link MS galvanised fencing , any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and as directed. |
| 13 | Fixing only chain link fencing including line wires any mesh, size and type to any type of standards rails straining bolts etc including provision of binding wire complete all as specified and as directed. |
| 14 | S&F Mild steel screw bolts 11 to 15 mm dia of neck (machine made) with hexagonal or square head at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 10 cm and n.exc 15 cm long. complete all as specified and as directed. |
| 15 | Supply & fix only 10 mm dia and over, Ms round bar as in line wire conforming to Fe-410-W (Gde.E-250) quality-A or Fe 290 (Gde -E-165) for fixing of chain link fencing complete all as specified and as directed. |
| 16 | Supply and fix galvanized, 2 strand,steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type or standard rails, straining bolts, including, securing or tying at crossings with and provn of galvanized mild steel wire,staples or steel pins etc complete all as specified directed Note : Each line wire to be measured and paid separately. |
| 17 | M&L for applying two coat of synthetic enamal paint over a coat of red oxide zinc chrome primer on new steel surface of n.exc 10 cm width / girth including preparation of surface complete all as specified and directed. |
| 18 | Material and Labour applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel surface exc 10 cm width or girth complete all as specified and as directed . |
| 19 | Demolition of cement concrete (unreinforced) of any descriptions, in Ground floors (Floor Topping, Sub Base etc) not exc 150mm thick, above or below ground level complete all as specified and directed. |
| 20 | M&L 100 mm thick PCC 1:4:8 type D2 using 40 mm graded aggregate as in sub base |
| 21 | M&L for sand (cushioning) filling under floors including watering and consolidation all as specified and as directed by Engr- in -charge. |
| 22 | M&L in repairs Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 grade with gray cement and pigment etc, complete all as specified and as directed by Engineer-In- Charge. |
| 23 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 24 | M&L 10 mm thick rendering in CM 1:4 complete all as specified and directed. |
| 25 | M&L Coloured glazed ceramic tiles glossy finish of size 300x450x7mm thick in dado’s/skirting etc. set and jointed in neat cement slurry and pointed in white cement & pigment to match the colour of tiles complete all as specified and directed. |
| 26 | M&L for 15mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and directed. |
| 27 | M&L for coloured non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 28 | M&L 10 mm thick light shade Vitrified tiles (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm laid over 15mm thick screed bed or bedding layer in cement mortar1:4 as in skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tile, etc complete all as specified and directed. |
| 29 | Taking down shutters of any description exc 1 sqm but n.exc 2 sqm each complete all as specified and as directed. |
| 30 | Taking down shutters of any description n.exc 1 sqm each complete all as specified and as directed. |
| 31 | S & f anodised aluminium door shutters,aluminium section weighing 0.55 kg/m including necessary joining cleats ,glazing cleaps,rubber neoprene packing ,handles 02 nos in each door ,hinges,aluminium anodised snap beading scews etc complete all as specified and directed. |
| 32 | S & F anodised aluminium window and ventilator shutters, side hung type/sliding type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed. |
| 33 | Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets any thickness including cover fillets/ old aluminium snap grid in any height (including scaffolding if required) for all type building complete all as specified and as directed. |
| 34 | Supply & Fix suspended false ceiling system using suspended ceiling grid system with the size of grid as 600mm x 600mm with powder coated GI frame work, main runner 38 x 24mm, cross tee 38 x 24mm and wall angle 22.20mm x 22.20 mm using 9 mm thick Gypsum board tiles with PVC vinyl face on one side and aluminium foil on other side. The suspended ceiling grid system shall be duly suspended by 4 mm dia GI bar hangers from the purlins/ RCC roof with butterfly clips complete all as specified and as directed. |
| 35 | S & F wall panelling on existing wall surface made out of PVC hollow profile section of size 150mm x 10mm with a wall thickness of 1mm (+/-) 0.2mm to be fixed on wall by self tapping scew of size 19mm x 6mm after fixing rawl plugs.The edge and periphery finaly to be covered by extruded PVC corner angles beading section of size 28mm x 12mm with wall thickness of 1mm complete all as specified and as dirceted. |
| 36 | Dismantling plain or corrugated steel sheeting and translucent corrugated sheeting, any gauge, thickness, in roof covering of height upto 20.0 mtr from avg ground level (including scaffolding if required) for all type building complete all as specified and as dirceted. |
| 37 | S & F Galvanised, corrugated mild steel sheeting 0.63 mm thick, any description with two corrugation side lap, fixed with L/J type hooks/bolts and washers, in roofs, walls of height upto 20.0 mtr from avg ground level (including scaffolding if required) for all type building, etc complete all as specified and as directed. |
| 38 | S & F 0.80 mm thick plain galvanized PGI sheets in ridges, hips ,valley gutters, etc class 8 ,fixed with L or J type hooks or bolts and washer upto 20.0 mtr height from avg ground level (including scaffolding if required) for all type building, complete all as specified and as directed. |
| 39 | Taking down/removing of existing water proofing felt on roof surfaces and wall surfaces at height upto 20.0 mtr from avg ground level (including scaffolding if required) for all type building and preparation the roof surfaces for new treatment complete all as specified and directed. |
| 40 | M & L in repairs APP based polymeric water proofing membrane ,five layered, of weight not less than 3 Kg per Sqm with centre layer core of 90 micron high molecular density polyethylene film and minimum 3mm thick reinforced with polyster non woven fabric (weight not less than 150 gms/sqm) laid on primed surface by forced application complete all as specified and directed.Note : The rate quoted shall be deemed to include for dismantling and refixing in position of wind tie and lightening protection after carrying out the treatment at height upto 20.0 mtr from avg ground level (including scaffolding if required) for all type building complete all as specified and as directed. |
| 41 | M&L for applying evenly a tack coat for roof treatment of industrial bitumen 85/25 at the rate of 0.40 Kg per Sqm including cleaning surfaces, complete at height upto 20.0 mtr from avg ground level (including scaffolding if required) for all type building complete all as specified and as directed. |
| 42 | Material and labour for providing reinforced cement concrete (1:2:4 ) type B1 (using 20 mm graded stone aggregate) as in slab supported on wall .complete all as specified and directed. |
| 43 | Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work;not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed. |
| 44 | Material and Labour TMT bar 10mm dia and over cut to length, bent to shape as required and binding with MS wire n.less than 0.9 mm dia annealed or fixed with welding complete all as specified and as directed . |
| 45 | All as per Item No-44 above but 6 to 8 mm dia . |
| 46 | Excavation in trenches, not exceeding 1.5 m wide or not exceeding 10 sq m on plan and not exceeding 1.5 m in depth for foundation of manhole etc and getting out as in hard/dense soil complete all as specified & directed. |
| 47 | Returning , filling in hard/dense soil including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick , including watering ,ramming complete all as specified and as directed . |
| 48 | Removing of soil to distance n.exc 50 mtr and depositing at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed . |
| 49 | Supply and fix in repair laminated wooden flooring of size 1214mm x 193mm x 8.00mm thick type AC-3 and fixing by using a coat of approved adhesive not less than 1.32 kg/sqm by weight over 2mm thick foam over existing surface complete all as specified and directed. |
| 50 | Material and labour for applying one coats of white wash on wall surface complete all as specified and as directed . |
| 51 | Supply and fix in repairs 15 mm CP Bib taps, fancy type cast copper alloy with crutch handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed. |
| 52 | Supply and fix in repairs PVC connection 15 mm dia with PTMT nut of length 600 mm complete all as specified and as directed. |
| 53 | Supply and fix in repairs 15 mm CP Stop valves/Angle cock , fancy type cast copper alloy screwed down, high pressure, with crutch handle , screwed both ends and fixed complete all as specified and as directed. |
| 54 | Supply and fix in repairs PVC (SWR) floor trap, plain with grating 75mm dia including jointing with solvent cement , complete all as specified and as directed. |
| 55 | Supply and fix in repair 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed. |
| 56 | Taking up or down steel tubing and connections including cleaning for refixing or removal to store with all fittings for 15 mm bore GI tubing complete all as specified and as directed. |
| 57 | Supply and fix GI tubing medium grade 15mm bore dia with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed. |
| 58 | Supply and fix in repairs Health faucet (ABS body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connection and fixed in position complete all as specified and directed. |
| 59 | S&F in repairs vitreous china water closet Padestal pattern( white ) with seat cover excluding fixing bolts, flushing cistern and flush pipe complete all as specified and directed. |
| 60 | Supply and fix in repairs 10 ltrs capacity (PVC), valve less, syphonic action type, fluhsing cistern, low level, white, with inlet, ball valve, float and handle including brackets,incl PVC 32mm flush pipe, etc, complete all as specified and directed. |
| 61 | S&F in repair vitreous china,white, wash hand basin with pedestal, flat back size 550x400mm 'including MS brackets,pillar tap fancy type including cutting for and pinning complete all as specified and as directed. |
| 62 | Supply and fix in repairs vitreous china water closet (squatt type) orrisa pattern 580x440 mm size pan, white with front or back inlet with integral 'foot rests including provn of lime concrete bedding fixing of PVC \\"P'' trap 110 mm bore and connections to 'flushing cistern/pipe complete all as specified and directed. |
| 63 | S & F solid PVC door frames of size 50x47mm made out of 5mm plain colour PVC sheet supplying and fixing in opening as per specification and drawing shown in SSR complete all as specified and as directed. |
| 64 | Taking dwon chowkhate with shutter (without taking off shutters from phrames) n.exc 1.5 sqm each complete all as specified and as directed. |
| 65 | M&L point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 1.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through PVC conduits concealed/surface with new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified. |
| 66 | All as per item no. 68 for One 6 A socket outlet, independent, with cables 1.5 mm² size |
| 67 | Supply and fix modular switch,1way, 1 modole 6 Amp single pole,oneway complete all as speciifed and as directed |
| 68 | Supply and fix modular Socket, 6A - 2/3 pin combined 2 module,compelete all as specified and directed. |
| 69 | M&L point wiring using approved colour coding as per IS for one light/bell/buzzer point controlled by one switch or one fan point controlled by one switch & fan regulator with PVC insulated, unsheathed FRLS multi stranded copper conductor 2.5 sqmm (nominal area) 1100 volt grade cable for phase & neutral drawn through PVC conduits concealed/surface with new modular sunken boxes and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface in touch with wall including 1.5 sqmm (nominal area) copper conductor PVC insulated, unsheathed, multi stranded FRLS cable as earth wire and connected to earth dolly complete all as specified and as directed including cutting chases to wall and making good the disturbed surfaces to match with the existing specifications complete all as specified. |
| 70 | Supply and fix modular socket 16A - 2/3 pin combined 2 module, compelete all as specified and directed. |
| 71 | S & F single pole & neutral, modular type, double door, metallic distribution board 8 way conforming to IEC 61439-3, suitable for flush / surface mounting with provision for DP RCCB / RCBO / Isolator / MCB as incomer and SP MCBs as outgoing, reversible metal door, 200 A busbar, fully shrouded neutral bar, earth bar, wire set & cable ties for cable management, pre fitted masking sheet, etc. having IK 09 & IP 43 protection complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. |
| 72 | S & F triple pole & neutral, modular type, double door, metallic distribution board, 4 way conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FP RCCB / RCBO / Isolator / MCB as incomer and SP/TP MCBs as outgoing, reversible metal door, 100 A copper busbar, fully shrouded neutral bar, earth bar, wire set & cable ties for cable management, pre fitted masking sheet, etc. having IK 09 & IP 43 protection complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. |
| 73 | S&F MCCB 63 Amp 4 pole complete all as specified and directed |
| 74 | S&F MCB SPN 6 to 40 Ampp complete all as specified and directed |
| 75 | S&F SP 6- 32 A, 230 V, 50 Hz, 1P MCB ('B' curve) |
| 76 | M&L in repair Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 4.00 sqmm (nominal area) 1100 volts grade cable as earth wire including suitable size of PVC conduit drawn through rigid Surface/concealed in PVC casing caping/ PVC conduit, heavey duty and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed. Note: Two runs each of 4.00 sqmm main cable and one RM of 4.00 sqmm cable as earth wire together alongwith conduit shall be considered as 1 running metre for payment purpose. |
| 77 | M & L for earthing complete with GI earth plate electrode of 60 cm x 60 cm x 6 mm size, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI wire of diameter 4.0 mm as earth lead, by means of bolts, buts, check nuts and washers of galvanised iron or steel, galvanized iron pipe of 15 mm diameter, connected to earthing test point, all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion and including excavation, earthwork, PCC earth pit of dimensions 550 mm X 550 mm (outer) and 300 mm X 300 mm (inner) and 250 mm deep, with a 10 mm thick CI cover, hinged to CI frame on ground level, GI watering pipe, funnel, etc. complete all as specified and directed by the engineer-in-charge. |
| 78 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. |
| 79 | Supply and laying for earth continuity conductor or main galvanised steel wire of dia 4mm mm burried in ground, fixed to wall, any other indicated situation for loop earthing and the like upto test point on necesarry insulators and fastning screws, rawl plugs complete all as specified and directed. |
| 80 | M&L in repair Sub main wiring using approved colour coding as per IS with two single core, PVC insulated, unsheathed FRLS multistranded copper conductor of size 2 core, 1.5 sqmm (nominal area) 1100 volts grade and one single core, PVC insulated, unsheathed FRLS multistranded copper conductor including suitable size of steel conduit concealed heavey duty and connected to main board and making good disturbed surface after taking out old unserviceable sub main wiring and disposing from site complete all as specified and as directed. |
| 81 | Supply and fixing in repair/replacement of analogue addressable Multi-Detector having removable high performance chamber with Twin fire LEDs allow 360° viewing, lock mechanism (sensor to base), Variable sensitivity, Electronically addressed along with mounting base duly approved by LPCB including taking out old unserviceable necessary connections complete all as specified and directe Make : Haneybell/Apollo/Rowell/Notifire |
| 82 | Supply and fixing in repair/replacement of response Indicator complete all as specified and directed including taking out old unserviceable necessary connections complete all as specified and directed. MAKE- Ceasefire-Hochiki, Notifire, Honeywell, Apollo. |
| 83 | Supply and fixing in repair/replacement of analogue addressable Manual Call point ESP Analogue Addressable Protocol having status LED for Alarming and standby mode, Electronically addressed, resettable type duly approved by LPCB including taking out old unserviceable necessary connections complete all as specified and directed. MAKE- Ceasefire-Hochiki, Notifire, Honeywell, Apollo. Please Enable Macros to View BoQ information |