| 1 | Excavation post holes (or similar holes) each not exceeding 0.5 cum getting out in soft/loose soil , returnig filling in and ramming earth or broken rubble mixed with earth around in layers n.exc 25cm watering and removing surplus soil to a distance not exceeding 50m and making good surfaces complete all as specified and directed. |
| 2 | Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and not exceeding 1.5m deep in soft/loose soil complete all as specified and as directed. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm using available soil obtained from excavation complete all as specified and as directed. |
| 4 | Removal of excavated material [Soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. |
| 5 | M & L for PCC 1:2:4 type B2 (using 40mm graded stone aggregate) in foundations, filling and mass concrete complete. |
| 6 | S&F Rolled Mild Steel sections as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc(conforming to Fe 410-W (Gde E-250) quality A) complete all as specified and as directed. |
| 7 | S&F Rolled Mild steel sections as in Vertical post, main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates(conforming to Fe 410-W (Gde E-250) quality A) complete all as specified and as directed. |
| 8 | S&F Plates( Plain or chequred) channels, square cut or notched (ordinary and counter sunk ) conforming holes without any attchement (conforming to Fe 410-W (Gde E-250) quality A) complete all as specified and as directed. |
| 9 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as manufacturers instruction and as directed. |
| 10 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as in ridges, hips, valley gutter, drip, and straight flashing complete all as specified and as directed. |
| 11 | S&F Aluminium flat iron work in wind ties 40x6mm size fixed with 50mm/ 75 mm aluminium self staging screws with integral EPDM washer screwed in roof covering all as directed. (Note :- Height of the bldg up to 15 mtrs including necessary safety arrangements) etc., complete all as specified and as directed. |
| 12 | S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall/ vertical support for rain pipe complete all as specified and as directed. |
| 13 | S&F 110mm bore PVC (SWR) bends any radius suitable for PVC (SWR) pipe complete all as specified and as directed. |
| 14 | M&L Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width type C-1 (1:3:6) using 20mm graded stone aggregate and setting in cement mortar (1:4) complete all as specified and as directed. |
| 15 | M&L for rendering 15mm thick plaster in CM (1:4) on concrete or block masonry surfaces and finishing the surfaces even and fair complete all as specified and as directed. |
| 16 | M&L for PCC (1:4:8) type D2 (using 40mm graded aggregate) 75 mm thick as in subbase of flooring complete all as specified and as directed. |
| 17 | M&L for 50 mm thick crushed Sand under paver block including watering and consolidation complete all as specified and as directed. |
| 18 | M & L Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness M-40 grade complete all as specified and diected. |
| 19 | M&L Providing , cement concrete as in coping , mud stops, rounded or chamfered on edges Type B1 (1:2:4 ) using 20 mm graded aggregate complete all as specified and as directed. |
| 20 | Preparation of New or previously untreated steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of red/zinc oxide primer complete all as specified and as directed. |
| 21 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed. |
| 22 | Supply and install hi wall split units indoor & outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating of capacity 2.0 TR including required gas charging and dismantling old one and depositing to MES store yard complete all as specified and directed. |
| 23 | Supply and install hi wall split units indoor & outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating of capacity 1.5 TR including required gas charging and dismantling old one and depositing to MES store yard complete all as specified and directed. Please Enable Macros to View BoQ information |
| 24 | Supply and install hi wall split units indoor & outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating of capacity 1.5 TR including required gas charging and dismantling old one and depositing to MES store yard complete all as specified and directed. Please Enable Macros to View BoQ information |