| 1 | DSR item No. 40.9 Supplying Installation Testing and Commissioning of PTZ (Pan, Tilt and Zoom) IP IR Camera having following specifications and features etc :-(Please refer DNIT for complete specification of item no.1) |
| 2 | DSR item No. 42.4 LED DisplaySupplying, Installation, Testing and Commissioning of following size LED display (LED monitor) industrial grade with 3840x2160 resolution or better, USB playback, bluetooth and miracast connectivity, 4X HDMI 2.0, DP 1.2, HDR 10/10+, brightness: 500-nits or better, Video wall mode should be available, contrast ratio: 1200:1, OPS slot, viewing angle (H/V): 170°/ 170°, response time less than 12ms, Display control shall be on monitor screen and programmable with remote (remote shall be supplied with system), Key Board, Optical Mouse, etc. as required. |
| 3 | 55 inch or larger |
| 4 | DSR item No. 40.10 Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels having specifications and features etc (Please refer DNIT for complete specification of item no.3) |
| 5 | DSR item No. 40.12 Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications. |
| 6 | 6TB (Terabytes) |
| 7 | DSR item No. 39.1 Supplying, installation, Testing and commissioning of following capacity 8 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: Minimum 8 X RJ-45 Gigabit Ethernet Ports and additional 2 X 1G SFP Ports with non-blocking architecture by having Switching capacity of minimum 20Gbps and packet forwarding (Please refer DNIT for complete specification of item no.5) |
| 8 | 8 port PoE Layer 2 Network Switch with PoE Support of 130W or higher with each copper port supporting 802.3at PoE+. |
| 9 | DSR item No. 39.11 Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel 24 Ports Cat-6 Patch Panel should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. |
| 10 | DSR item No. 39.12 Supplying, Installation, Testing and commissioning of following CAT6 Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. |
| 11 | Copper Patch Cords of length 1m (3ft) |
| 12 | DSR item No. 39.23 Supply and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required. |
| 13 | 15U Rack |
| 14 | DSR item No.39.26Supplying and fixing Outdoor Pole/ Wall mount 6U Rack, IP55, Front Door with Filter, Louver & Unique key Lock. 3 Socket PDU 5Amp - 1 No. Self adhesive thermal foam from inside. Hood For Air Inlet at front side.1U Cantilever Tray 250mmDepth, Gasket. etc complete as required. |
| 15 | DSR item No. 39.19 Supplying and drawing following core Fiber Optic Cable having corrugated steel armoring. The Fiber should be SM Fiber Central -loose tube filled with Thixotropic jelly, duly following Standards: ISO 11801, IEC 60793-1/60794-1-2, ITU-T-REC G.652D and Telecordia GR-20-core, High quality Electro Chromium Coated Corrugated (Please refer DNIT for complete specification of item no.10) |
| 16 | Single Mode 6 Core Optical fiber cable |
| 17 | DSR item No. 39.6Supplying, Installation, Testing and commissioning of small form-Pluggable (SFP) for Network Switches. Must be hot Pluggable, RoHS Complaint, etc. complete as required. |
| 18 | 1G SFP Single Mode/Multi Mode |
| 19 | DSR item No. 39.21Supply and fixing following port Rack Mount loaded LIU with pigtail, Front-mounted cable saddles for jumper management, suitable to manage both splices and terminations, Pre-assembled shelves in multiple configurations, Rubber fiber slotted bracket built-in, metal splice shelf to protect the fibers, 2 fiber spools built-in for 900μm tight buffered fiber storing, Capable of storing up to 3 meters of 900μm tight buffered fiber per adapter, Removable front and rear covers for better access to interior of LIU, Should be Single / Multi mode LC Type fully loaded. Accessory kit consists of cable ties, mounting ear screws, and spiral wrap tube etc complete as required. |
| 20 | 6 Port LIU |
| 21 | DSR item No. 39.22Supplying and fixing Patch Cord of Optical Fiber Multi Mode or Single Mode LC to LC Fiber Duplex having high precision ceramic ferrule with good concentricity, Fiber corning single mode G652D, Cable Type 2mm with Mechanical specification Apex Offset ≤50 µm, Fiber Height ± 100 nm, End-face radius of Curvature 7mm < R ≤ 0.2 db, Working ambient Temperature – 5 °C to +50 °C, Storage Temperature – 10 °C to +50 °C, Length -- 2meter, Type -- LC-LC Duplex etc complete as required. |
| 22 | DSR item No. 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 23 | 25 mm |
| 24 | DSR item No. 39.17 Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range: -5° to +60°C. Bending Radius: < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force: 11.5Kg etc. complete as required. |
| 25 | 1 Run of cable |
| 26 | DSR item No. 15.16Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 27 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 28 | Supplying and drawing of 3 x 2.5 sq. mm copper conductor PVC insulated FRLS cable. The copper cable should be of Polycab/ Havells/ RR Kabel/ KEI/ Finolex only. |
| 29 | S/E of 7 Mtr. long Hot dipped Galvanized pole of octagonal cross-section continuously tapered made out from high tensile steel of minimum thickness 3mm complete with the base plate of minimum size 220mm x220mm x12mm alongwith inbuilt lockable junction box which should be operated with single key with connectors of Elmax / Connectwell / Essen / Wago make for the cable termination as per site requirement and one no. 6 Amps. Single pole MCB for each luminaire. (Please refer DNIT for complete specification of item no.18) |
| 30 | DSR item No. 2.6 (Civil work) Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and for all lift, as directed by Engineer-in-charge. |
| 31 | All kinds of soil (Size 0.7mx0.7mx1.65m = 0.81 cum (3 x 0.81 Cum = 2.43 Cum) |
| 32 | DSR item No. 4.1 (Civil work)Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 33 | 1:5:10 (1 cement: 5 fine sand derived from natural sources: 10 graded stone aggregate 40mm nominal size derived from natural sources) (0.7m x 0.7m x 0.10m = 0.049 cum.) (3 x 0.049 = 0.15 Cum) |
| 34 | DSR Item No. 5.22(Civil work) Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. |
| 35 | Thermo-Mechanically Treated bars of grade Fe-500D or more1.Vertical Bar 12mm dia =4 nos.x1.55=6.2 r.mtr. @0.89 kg per mtr. =5.52 kg2.Horizontal Ring 8mm dia =11 nos.x2=22 [email protected] per mtr.=8.58kg Total (5.52+8.58=14.1+5% wastage =14.81 Kg. (3 x 14.81 = 44.43 Kg) |
| 36 | DSR item No. 5.1(Civil work)Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : |
| 37 | 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources) Size 0.5x0.5x1.55 = 0.388 cum (3 x 0.388 Cum = 1.16) |
| 38 | DSR item No. 5.9 (Civil work) Centering and shuttering including strutting, propping etc. and removal of form for |
| 39 | Foundations, footings, bases of columns, etc. for mass concrete Size 4 (0.5 x 1.55) = 3.1 sq. mtr. (0.5 x 1.55) x 4 = 3.1 Sq. Mtr. (3 x 3.1 = 9.3 sq. mtr.) |
| 40 | Providing comprehensive AMC for 5 year (after expiry of defect liability period i.e. 1 year) for the various components as above including all part of hardware as well as software. Preventive Maintenance service of the equipment under AMC must be carried out once in fortnight. (Please refer DNIT for complete specification of item no.24) |
| 41 | 2nd year |
| 42 | 3rd year |
| 43 | 4th year |
| 44 | 5th year Please Enable Macros to View BoQ information |