| 1 | Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. Gr.'C' |
| 2 | Light Point |
| 3 | Fan Point |
| 4 | EX/ Fan Point |
| 5 | Call bell Point |
| 6 | Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. |
| 7 | 2x1.5 Sq. mm +1x1.5sqmm earth wire |
| 8 | Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required. |
| 9 | Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required. |
| 10 | Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. |
| 11 | 2x2.5 Sq. mm +1x2.5sqmm earth wire |
| 12 | 2x10 Sq. mm +1x6sqmm earth wire |
| 13 | Supplying and fixing G.I. Modular box with modular plate and cover in recess including providing and fixing 3 pin 5/6amps modular socket outlet and5/6 amps, modular switch, connections etc. as required. |
| 14 | Supplying and fixing G.I. Modular box with modular plate and cover in recess including providing and fixing pin15/16amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required. |
| 15 | Supplying and fixing call bell / buzzer, suitable for D.C./A.C. single phase,230 volts complete as required:- |
| 16 | Supplying and erection of 5 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:- |
| 17 | MCB SP 6A |
| 18 | MCB SP 16A |
| 19 | Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 30 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 20 | Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:- |
| 21 | 12way Doubledoor |
| 22 | Earthing with G.I earth pipe 4.5 mtr. long and 40mm dia, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required. |
| 23 | Earthing with copper earth plate 600 mm x600 mm x 3mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc.without charcoal / coke and salt complete as required. |
| 24 | Supplying and laying 6 SWG G.I. wire at 0.50 mtr. below ground level for earth electrode conductor, including soldering etc. as required. |
| 25 | Providing& fixing 6 SWG dia G.I.wire on surface or in recess for loop earthing as required. |
| 26 | Providing & installation exhaust fan of following sizes in existing opening, Double ball bearing type metal frame including making the hole to suit the size of the above fan, making good the damages,connection,testing& commissioning etc, as requiredof Apporoved make Domestic type. |
| 27 | Exhaust Fan, Light duty, (Domestic) 300mm sweep |
| 28 | S/E of LED Batten with aluminium extrusion housing The fitting should be installed on existing surface The job includes carriage, erection, making connections testing and commissioning of the fittings. |
| 29 | LED Batten Light 1000 lumen |
| 30 | LED Batten Light 2000 lumen |
| 31 | S/E of LED Downlighter round type surface with CRCA/PDC body and diffuser The fitting should be installed on existing surface The job includes carriage, erection, making connections testing and commissioning of the fittings. |
| 32 | Squar LED Down Light Surface Lumen ouputof the fitting 425 |
| 33 | Squar LED Down Light Surface Lumen ouputof the fitting 1275 |
| 34 | Supplying, installation,testing & commissioning of following sweep, BEE 5 star rated, ceiling fan with brush less direct current (BLDC)Moter, class of instsllation;B,3NO, BLADES, 30CM LONG DOWN ROD, 2no,canopies shackle kit, safty rope,copper winding,power factor not less than 0.9,service value (CM/M/W)minimum6.85,Air delivery minium 215 CMM,300RPM( tolerance as per IS:374-2019), THDless than 10% remote BLDCelectronic regulater unit for speed control and all remaining accessaries including safty pin, nut bolts,washers,temperature rise =75 degree c(max.),installation resistance more than 2 mega ohm suitable for 230V50Hz, single phase A.C.supply, earthing etc complete as required. |
| 35 | Ceiling fan 1200mm sweep. |
| 36 | Providing7 installationof stationarystore type Electric water Heater Geyesar of various sizesesby means of expitions -bolts with nuts 7 washers ,including embending of bolts in expection -bolts in the wall providing & fixing of non return valve ,Deadweight safty valve 2No CP cocnnection rod 18\\"long making good the damages electrical connection ssafty valve connections,testing &commissioning etc as required. |
| 37 | 25 Ltr capcity Water Heater (Geyesar) Please Enable Macros to View BoQ information |