| Sl. No. | Item Description |
| 1 | Taking Down Chowkhats or Frame with Shutter ( with out taking out shutter from the frame ) exc 1.50 sqm not exceeding 4.0 sqm each as doors , windows & ventilators etc and removal from site complete all as specified and directed |
| 2 | Taking Down Chowkhats or Frame with Shutter ( with out taking out shutter from the frame ) not exceeding 1.50 sqm each as doors , windows aaa& ventilators etc and removal from site complete all as specified and directed. |
| 3 | Demolition of cement concrete (un reinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed. |
| 4 | Supply only Integral water proofing Compound complete all as specified and directed. |
| 5 | Waterproofing treatment to sunken floor using acrylic based multipurpose polymer. The treatment shall be carried out as per manufactures specification. The treatment shall be include 1. Surface preparation of substrate by removing all traces of contaminates, loose and friable particles, cement laitance oils and grease, water repellent coatings etc2. Injection grouting using cementitious grout if required. The payment for injection grouting shall be made separately etc3. Repair to the substrate, filling of blow holes/voids and surface leveling using appropriate products specified by the manufacture.4. All intersections of horizontal and vertical surface should be profiled with a mortar fillet of minimum 25mm x 25mm.5. The moisture content of the substrate shall be checked before application of first coat at water proof coating at the rate of 200 g/m2 followed brush topping at 450g/m2 per mm. The second coat shall be reinforced with glass fabric between the first and second coat.6. The treatment shall be protected by application of polymer modified cement mortar of thickness 10mm applied at the rate of 50g per mm.7. Tech specification. |
| 6 | M&L for AAC Blocks as in filling of sunken floors including fixing with adhesive complete all as specified and directed. |
| 7 | S&F Factory made single extruded WPC ( Wood Polymer Composite ) Solid Door Frame /Chowkhat of Size 45mmx70 mm comprising of virgin polymer of K value 58-60 (susension grade ), Calcium Carbonate and nautral fibers ( Wood Powder /rice husk/wheat husk ) and non toxic additives (max toxcity index of 12 for 100 gms ) fabricated with miter joints after applying PVC Solvant cement and screwed with full body threaded star headed SS screws having minimum density of 750 kg /cum and screw withdrawl strength of 2200 N (face ) & 1100 N (Edge) minimum Compressive strength of 508 N /sqmm modulus of elasticity 900 N/Sqmm and resisitence to spread of flame of class A cat with property of being termite / borer proof , water moistur proof and fire retaident and fixed in position With MS hold Fast /SS Dash Fastner incl S&F (03 Nos Per Frame ) 100 mm long SS Butt Hinges complete all as specified and directed. |
| 8 | S&F Factory made single extruded WPC ( Wood Polymer Composite ) Solid Plain flush door shutter of 30 mm size comprising of virgin polymer of K value 58-60 (susension grade ), Calcium Carbonate and nautral fibers ( Wood Powder /rice husk/wheat husk ) and non toxic additives (max toxcity index of 12 for 100 gms ) having minimum density of 650 kg /cum and screw withdrawl strength of 1800 N (face ) & 900 N (Edge) minimum Compressive strength of 50 N /sqmm and resisitence to spread of flame of class A cat with property of being termite / borer proof , water moistur proof and fire retaident and fixing and incl S&F of 02 Nos (per Leaf) SS 150mm long Tower Bolt and S&F of 02 Nos (per Leaf) SS 150mm long handle complete all as specified and directed. |
| 9 | Aluminium powder coated ventilator including provision of neccessary rubber gasket for fixing glass panes etc shown in drawing No CEBT/SK-936 sheet 1/1. complete all as specified and directed.Note: Glass panes and wiremesh shall be measured and paid seperately under respectively Items of BoQ. |
| 10 | S & F 4 mm thick figured glass, pin head type and glazing with oil putty in ventilator complete all as specified and directed. |
| 11 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish to a distance exceeding 1 km but not exceeding 2 km complete all as specified and directed. |
| 12 | M&L Wet grip coloured ceramic tiles 9 to 10 mm thick ( square / rectangulr) of size 300mmx300mm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick bedding layer using type-I adhesive (thick bed fixing) confirming to IS-15477:2004 and pointed in Epoxy grout to match the shade of tile including necessary cutting as per site requirement and as per manufacturers instructions complete all as specified and directed. |
| 13 | S&F glazed ceramic coloured tiles 600 x 300mm, 9 to 10mm thick in verticle surfaces such as dado / skirting, including 10mm thick bedding layer using type-I adhesive (thick bed fixing) confirming to IS-15477:2004 and pointed in Epoxy grout to match the shade of tile including necessary cutting as per site requirement and as per manufacturers instructions complete all as specified and directed. |
| 14 | M&L for marble work (Udaipur green slabs) in one piece 15 to 18 mm thick slab of cills of windows and urinal partition and like in laid over and including M&L for 15 mm thick cement mortar (1:4) and pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade and roundening to the edge of stone slabs on edges etc. complete all as specified and directed. |
| 15 | S&F in repairs, CP basin mixture single lever type and fixed complete all as specified and directed. |
| 16 | S&F in repairs, PVC connection 15 mm bore dia and 600 mm long complete all as specified and directed. |
| 17 | S & F 15 mm bore chromium plated fancy type stop valve of cast copper alloy screwed down high pressure with crutch butter fly handle screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. |
| 18 | S&F in repair brass chromium plated shower rose 70 mm of size with arme and with or without swivel joints to steel pipe or union complete all as specified and directed. |
| 19 | S & F in repairs 15 mm dia bore chromium plated quarter turn concealed stop valves of cast copper alloy fancy type with long shank & cup etc. complete all as specified and directed. |
| 20 | S&F in repairs brass chromium plated soap tray 100x100x6 mm soap tray complete all as specified and directed. |
| 21 | S&F in repair 15 mm dia ISI Mark bore chromium plated long body with wall flanges bib taps cast copper alloy, screwed for iron pipe, or for brass ferrule complete all as specified and directed. |
| 22 | S&F CP grating Doom 125 mm dia with aste hole complete all as specified and directed. |
| 23 | S & F bevelled edge mirror 5 mm thick selected quality glass mounted on walls fixed to chromium plated brass screws and cup washers complete all as specified and directed. |
| 24 | S&F 16 mm CPVC pipe sdr11and plain CPVC sdr11 fitting with all fitting and fixed to walls & ceilings or laid in floors, bore of pipe 15 mm including taking down old pipes of 15mm bore of any description complete all as specified and directed. |
| 25 | S&F 25 mm CPVC pipe sdr11and plain CPVC sdr11 fitting with all fitting and fixed to walls & ceilings or laid in floors, bore of pipe 25 mm including taking down of old pipes of 25mm bore of any description complete all as specified and directed. |
| 26 | S&F in repairs white vitreous china wash down water closet pan (pedastal pattern) with and including plastic water closet seat white black , closed pattern with flat bottom and cover and mild steel chromium plated or aluminum hinging device incl flush pipe and fixing bolts ( excluding flushing cistern) etc complete all as specified and directed |
| 27 | S&F in repairs vitreous china squatting pan, 'Orissa' pattern, size 580mm x 440mm, white, with integral foot rests including connection to trap, and to flushing pipe, anti-syphonage pipe, etc. including making good to floor and excluding flushing cistern, flush pipe and waste pipe complete all as specified and directed. |
| 28 | S & F in repairs PVC valveless, syphonic action type, flushing cistern, 10 litres capacity, low level, white, with inlet, ball valve, float and handle including brackets and PVC flushing pipe 32mm dia 900 mm long complete all as specified and directed. |
| 29 | S & F in repairs vitreous china, countertop oval shaped wash hand basin, white, of size 560mm x 450mm , including 32 mm dia brass chromium plated waste coupling and PVC waste pipe including angle iron brackets complete all as specified and directed. |
| 30 | S&F Vitrous china urinal half stall type white (excluding flushing cistern, flush pipe and waste pipe ) including connections to flushing pipe and out going pipes etc complete all as specified and directed |
| 31 | Dismentalling and disconnecting of existing CI soil vent pipe 100 mm bore fixed to wall , laid in trenches incl all fittings and accessories complete all as specified and directed. |
| 32 | Dismentalling and disconnecting of existing CI soil vent pipe 75 mm bore fixed to wall , laid in trenches incl all fittings and accessories complete all as specified and directed. |
| 33 | Taking down rain water pipe and evas gutters (any size and pattern) incl all fittings heads shoes bends swan necks etc,. complete all as specified and directed. |
| 34 | S & F 110 mm bore of pipe PVC (SWR) type B pipes single socket in any length with rubber ring joint fixed to walls with GI Brackets at a distence of 100-120mm away from walls complete all as specified and directed. |
| 35 | S&F 110 mm bore pipe PVC (SWR) bends of any radius / shoe fixed to PVC pipes complete all as specified and directed. |
| 36 | S & F in repair 75 mm bore of pipe PVC (SWR) type B pipes single socket in any length with rubber ring joint fixed to walls with GI Brackets at a distence of 100-120mm away from walls complete all as specified and directed. |
| 37 | S&F in repair 110 bore, PVC Swr bends Juction , Tee and Y (any radius), diminishing pieces or tapers (large bore measured) with oval access door as complete all as specified and directed. |
| 38 | S&F in repair 75 bore,PVC SWR , bends , junction , TEEand Y (any radius), diminishing pieces or tapers (large bore measured) with oval access door as complete all as specified and directed. |
| 39 | S&F in repair 75mm dia of long neck PVC SWR floor trap with grating incluing jointing to waste pipe fixed in cement concrete 1:2:4 type B1 complete all as specified and directed. |
| 40 | S&F in repair 100mm dia of long neck PVC SWR P trap with grating incluing jointing to waste pipe fixed in cement concrete 1:2:4 type B1 complete all as specified and directed. |
| 41 | S&F in repair Branch pieces,PVC SWR single 110 mm bore, equal or unqual, complete all as specified and directed. |
| 42 | S&F in repair Branch pieces, pvc SWR single 75 mm bore, equal or unqual, ordinary or inverted (spigot or socket type) or with oval acess door complete all as specified and directed. |
| 43 | Taking down old cement plaster including raking out joints hacking for key scrubbing down with water etc and removing rubbish from the premises to a distance exceeding 1 km but not exceeding 2 km etc complete all as specified and directed. |
| 44 | M&L for rendering 15 mm thick in cement mortar (1:6) on internal wall surfaces of brick work or concrete surfaces and finishing the surface even & smooth without using extra cement complete all as specified and directed. |
| 45 | M&L for rendering 15 mm thick in cement mortar (1:4) on external wall surfaces of brick work or concrete surfaces even and fair without using extra cement mixed with liquid water proofing material as per manufacturer's instruction complete all as specified and directed. (Liquid water proofing material shall be measured and paid for separately.) |
| 46 | M&L for rendering 10 mm thick in cement mortar in (1:3) finishing the surfaces even and smooth on ceiling complete all as specified and directed. |
| 47 | Dismentalling water tanks of exc 500 ltrs and n exc 1000 ltrs capacity water storage tanks remove from site complete all as specified and directed. |
| 48 | S&F 1000 litres capacity Rotational moulded polyethylene in white colour, three layered, water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed. |
| 49 | S&F ball valves high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for iron pipe of size 25 mm bore (minimum weight 210 gram) complete all as specified and directed. |
| 50 | S & F Gun metal globe or Gate valve , with iron wheel , screwed both ends for iron pipe or for unions for 25 mm bore dia of pipe complete all as specified and directed. |
| 51 | M&L applying two coat of white wash over new plastered surfaces of wall etc complete all as specified and directed. |
| 52 | M&L preparation of newly plastered or unplastered surface and applying three coats of white wash on ceiling complete all as specified and directed. |
| 53 | M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint of approved tint complete all as specified and directed. |
| 54 | Complete removal of exsiting treatment and preparation of surface applying two coat of white wash over old plastered surfaces of wall etc complete all as specified and directed. |
| 55 | Complete removal of exsiting treatment and preparation of old plastered or unplastered surface and applying two coats of cement base paint of approved tint complete all as specified and directed. |
| 56 | S & F CP health faucet 15 mm bore including 1 Mtr flexible led complete all as specified and directed. |
| 57 | S & F stainless steel fancy type peg set of six and fixed in position with steel screws complete all as specified and directed. |
| 58 | S & F 20 mm thick granite slabs for wash hand basin over 15 mm thick screed bed in CM 1:6 including moulding and nosing of corners/ edges complete all as specified and directed, |
| 59 | Material and Labour for providing precast cement concrete (1:2:4) type B1 using 20mm graded stone aggregate in cooking plateform/slab including necessary formwork and setting in mortar set in cement mortar (1:4) complete all as specified and as directed. |
| 60 | M&Lfor half brick work with sub-class 'B' bricks, straight or curved on plan exc 6m mean radius built in In cement mortar 1:4 complete all as specified and directed. |
| 61 | M&L for TMT bars 10 mm dia and over cut to length and bent to shape required including cranking, hooking ends and binding with and MS wire not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 62 | S&F Udaipur green marble slab 18-20mm thick as in corner shelf of 300mm radius including cutting 30mm groves in wall and jointed & pointed with cement slurry mixed with pigment to match with marble and rounding of edges complete all as specified and directed. |
| 63 | S&F SFRC (Steel fibre Reinforcement concrete cover & frame ) HD-20mm, ISI marked conforming to IS-12592, graded rectangular clear opening 560X560mm fixed over manhole after demolition of PCC coping & manhole Cover & set in CM 1:4 including PCC benching in CM (1:2:4) and finishing smooth complete all as specified and directed. |
| 64 | M&L Carefully chipping, removing existing loose/ damaged concrete with plaster from Roof, Ceiling, Chajja, Fascia, Fins, Drops and similar items by low impact high frequency hammer/ chipper without damaging the existing sound concrete and exposing old reinforcement upto 10mm beyond corroded reinforcement bars using electrically operated diamond concrete saw blade, making the edges straight and Cleaning all existing reinforcement bars in Roof, Ceiling, Chajja, Fascia, Fins, Drops and similar items with wire brush/rotary wire brush to make entire circumference surface of bars free from rust scales, loose material, dirt etc., complete and applying alkaline rust converting primer in 2 coats on the existing rebar and allowing it to react with rust for 6 hrs and form a corrosion resistant, insoluble and adherent protective layer including cleaning the reinforcement, wire brushing to remove the rust spalls, (consumption Qty as per manufacturer’s instructions but min 0.4 kg/Sqm approx for 2 Coats ) complete as per manufacturer’s instructions, complete all as specified and as directed.Note :- Mode of measurement : per sqm of breaking area of concrete only. |
| 65 | Providing and application of Zinc rich epoxy anti-corrosive protective coating for reinforcement bars as corrosion protection system in 2 coats to the entire circumference surface of bars (consumption Qty as per manufacturer's instructions but min 0.4 kg/Sqm approx for 02 coats) in Roof, Ceiling, Chajja, Fascia, Fins, Drops and similar items complete all as specified and directed by Engr-in-charge. The product should confirm carbonation resistance of 2 mm and bond strength > 1N/sqmm according to ASTM C 882-78 complete all as specified and as directed.Note :- Mode of measurement: per sqm of application area of concrete. |
| 66 | Apply SBR based bonding agent to the entire concrete surface prior to building up of concrete with Polymer modified mortar or any other treatment , (consumption Qty as per manufacturer’s instructions but min 0.4 kg/Sqm approx) including cleaning the surface to remove dirt, dust or any other impurities on the surface, etc. complete in Roof, Ceiling, Chajja, Fascia, Fins, Drops and similar items complete all as specified and directed. |
| 67 | Rebuilding the section of structural damaged RCC/PCC elements of Roof, Ceiling, Chajja, Fascia, Fins, Drops repair to spalling concrete to its original size and shape in layers of 10 mm average thickness in 1st layer by providing and applying with pre-batched, one component fiber based repair mortar having compressive strength >= 50 N/sqmm (28 days) according to ASTM C 109; flexural strength >= 5N/ sqmm (7 days) according to ASTM C 293-79 complete all as specified and directed. |
| 68 | M&L for 15 mm thick screed bed or bedding layer in cement mortar (1:3) on roof surfaces parapet or vertical beam surface (horizental or vertical) finishing the surfaces even and fair complete all as specified and directed.(Note :- Course sand (Toka sand) shall only be used in screed bed/plastering.) |
| 69 | Water proofing tratment to existing roof/terrace using sika coolcoat /or equivalent Single component, acrylic based, flexible, micro fibre reinforced waterproofing and heat reflective coating system. the treatment shall be carried out as per the manufacturers instructions and shall include.(a) Preparation of substrate and cleaning it off all loose and triable by mechanical means(b) Open the cracks lines to form , V grooves with cutter/hammer/chisel up to 5-10mm and filling with crack filler and PU sealant.(c) application of primer coat @ 0.2 to 0.3 kg/ sqm followed by the first coat @ 0.75kg/ Sqm.(d) The second coat shall be applied @ 0.75 kg / Sqm and reinforced with fabric re-inforcement between the first and second coat.(e) The top coat of primer shall be applied after the second coat dries off @ 0.05-0.08 Kg per Sqm.(f) The material shall adhere to following specification. TECHNICAL SPECIFICATION OF MATERIALTensile Strength 1.5 MPa ASTM D412Elongation at Break > 200% ASTM D412Adhesion in Peel > 1.5 MPa (on concrete substrate) EN 1542Crack Bridging Ability Passes upto 3.2mm Width ASTM C1305Permeability to Water Vapour Passes IS 2645Water Vapour Transimission ~ 23 g/m²/24hr ASTM E96Water Absorption < 10% ( by Mass) ASTM D570Microbiological Resistance No Algae & Fungal Growth ASTM D5590Solar Reflectance Index 102 ASTM E1980.Note : Complete material shall be procured in bulk and kept in lock and key.Note : The installation company should be trained and authorized by Manufacturer & installation to be carried out as per manufacturers approved method statement. All auxiliary & accessories involved during application should be supplied by single manufacturer as a part of system. Any component used which is not manufactured by the particular manufacturer can only be used with official approval from manufacturer |
| 70 | M & L in repair PCC 1:2:4 for PCC type B-1 using 20 mm graded stone aggregate as in coping benching , padding etc complete all as specified and directed. |
| 71 | S&F Salt-glazed stoneware gully traps of size 150 x 150 mm, square or round mouthed, type 'P' complete all as specified and directed. |
| 72 | Excavating in trenches, not exceeding 1.5metre wide and not exceeding 1.5metre depth for foundation, etc., and getting out in soft/loose soil, complete all as specified and directed. |
| 73 | M&L for plain cement concrete type D2, 1:4:8 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed. |
| 74 | M&L 75mm thick PCC 1:4:8, type D-2 (using 40mm graded crushed stone aggregate) as in sub base of flooring complete all as specified and directed. |
| 75 | Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6m mean radius built in in CM 1:6, complete all as specified and directed. |
| 76 | M&L for providing RCC 1:1.5:3 using 20mm graded crushed stone aggregate) in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns etc basements slabs, under reamed piles and mass concrete complete all as specified and directed. |
| 77 | M&L for providing RCC 1:1.5:3 using 20mm graded crushed stone aggregate) in columns, pillars, piers, posts and struts complete all as specified and directed. |
| 78 | M&L for providing RCC 1:1.5:3 using 20mm graded crushed stone aggregate) in beams, cantilevers, bressumers, lintels complete all as specified and directed. |
| 79 | M&L for providing RCC 1:1.5:3 using 20mm graded crushed stone aggregate) in slab supported on walls complete all as specified and directed. |
| 80 | Formwork to sides of concrete foundation, footings, bases of columns, rafts and raft beams, plinth beams and similar work; vertical or to batter for rough finished surfaces of concrete, complete all as specified and as directed. |
| 81 | Formwork to sides of pillars, posts, struts, columns (square, circular rectangular on plan or polygonal etc. for rough finished surfaces of concrete, complete all as specified and as directed. |
| 82 | Formwork to soffits of suspended slabs such as roof slab, floor slab, landings and similar work, not exceeding 200mm thick flat fair finished surfaces of concrete complete all as specified and directed. |
| 83 | Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floor and roofs n.exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 5 cm but n.exc 10 cm wide complete all as specified and directed. |
| 84 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished surfaces of concrete, complete all as specified and directed. |
| 85 | S&F mild steel TMT bars 8mm dia as in stirrups, cut to length bent to shape including binding with MS annealed wire of dia not less than 0.90 mm, complete all as specified and as directed. |
| 86 | M&L for rendering 5 mm thick in cement mortar 1:3 finishing the surface even and smooth on ceiling complete all as specified and directed. |
| 87 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed. |
| 88 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed. |
| 89 | S&F aluminium anodised 100mm long butt hinges with galvanised mild steel hinge pin,anodised and fixed, complete all as specified and directed. |
| 90 | S&F 150 mm long aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed. |
| 91 | S&F 125 mm long aluminium anodised,handle of extruded section cast type anodised and fixed complete all as specified and directed. |
| 92 | S & F 2nd class HW 35mm thick factory made panelled shutters with lock rail and panel of 9mm BWP commerical ply of 12mm veneered partical board with commerical veneering on both faces. The size of rail and style as per IS-1003 (Pt-I) liln seasoned and chemically pressure treated complete all as specified and directed. |
| 93 | S&F 300mm long Mild steel sliding door bolt, plate type store enamelled black with bright not less than 12mm dia with and including minium of 6 bolts and nuts four on plate and two on staples plat and fixed complete all as specified and directed. |
| 94 | S&F 200mm long mild steel barrel bolt, stove enamalled black bright bolt and fixed complete all as specified and directed. |
| 95 | S&F Steel pressed handle oval type stove enamelled black size 150mm complete all as specified and directed. |
| 96 | S&F steel ventilator with top hung shutter including hinges, steel peg stay complete all as specified and directed. |
| 97 | S&F stainless steel wire cloth 0.56 mm nominal dia of wire and avarage width of aparture 1.18 mm and fixed with tinned tacks ro galvanised wire stapple complete all as specified and directed. |
| 98 | M&L hard core of broken stone gauge not exceeding 63mm deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surfaces with broken bricks bats complete all as specified and directed. |
| 99 | M&L for 75mm thick plain cement concrete 1:3:6, type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection complete all as specified and directed. |
| 100 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick any type of soil, complete all as specified and directed. |
| 101 | Removing excavated soils to a distance exceeding 250m but not exceeding 500m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 102 | M&L Non skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc set and jointed in neat cement slurry /paste and pointed in white or coloured cement to match including 15mm thick screed bed or bedding layer in CM 1:4 complete all as specified and directed. |
| 103 | M&L for joint free glazed coloured ceramic tiles of approved quality in vertical surface 450mmx300mmx7 mm/ 600mmx300mmx7mm thick, set & jointed in neat cement slurry & pointed in coloured cement to match the tile over and including 10 mm thick rendering in CM 1:4 complete all as specified and directed. |
| 104 | S&F PVC low level cistern of 10 ltrs capacity with top push buttion inclusive of brackets and PVC bend long type and connectin to flush pipe of any size and pattern with inlet ball valve float and handle complete all as specified and directed. |
| 105 | S&F Wash hand basin of size 450x300 mm vitrous China white flat back including brackets, waste coupling & PVC waste pipe of 32 mm dia etc. complete all as specified and directed. |
| 106 | S&F Urinal spreader of PTMT any colour for fixing with 15mm dia pipe (minimum weight 60 gms). complete all as specified and directed. |
| 107 | S&F 20 mm CPVC pipe SDR 11 and Plain CPVC SDR 11 fittings with all fitting and fixed to walls & ceilings or laid in floors complete all as specified and directed. |
| 108 | S&F 500 litres capacity Rotational moulded polyethylene in white colour water storage tanks triple layer (cylindrical vertical with closed top) hoisted and fixed in position, including over flow and drain out pipe complete complete all as specified and directed. |
| 109 | S&F 20 mm bore dia of pipe Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 20mm -210 gms ) complete all as specified and directed. |
| 110 | S&F 15 mm dia chromium plated fancy type bib taps cast copper alloy, screwed for iron pipe, or for brass ferrule complete all as specified and as directed. |
| 111 | S&F 15 mm dia bore chromium plated quarter turn concealed stop valves of cast copper alloy fancy type with long shank & cup etc. complete all as specified and as directed. |
| 112 | S&F 15mm bore ISI chromium plated quarter turn Pillar cock screwed down high pressure, with or without lettered Hot ot Cold with long screwed shanks and flynuts screwed for iron pipe complete all as specified and directed. |
| 113 | S&F brass chromium plated shower rose 125 mm of size with arme and with or without swivel joints to steel pipe or union complete all as specified and as directed. |
| 114 | S&F chromium plated soap tray any type and fixed to plugs on wall with chromium plated brass screws complete all as specified and directed. |
| 115 | S&F 600x450mm bevelled edge mirror of slected quality glass mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plug with chromium plated brass screws and cup washers complete all as specified and directed. |
| 116 | S&F 100mm bore cast iron (spun) soil, waste and vent pipes, ISI marked in any length with or without ears, with cement joints, fixed to wall and including suitable size clamps/laid in trenches complete all as specified and directed. |
| 117 | S&F 75mm bore cast iron (spun) soil, waste and vent pipes, ISI marked in any length with or without ears, with cement joints, fixed to wall and including suitable size clamps/laid in trenches complete all as specified and directed. |
| 118 | S&F 100mm bore cast iron bends (any radius) diminishing peaces or tapers (large bore measured) with oval access door complete all as specified and directed. |
| 119 | S&F 75mm bore cast iron bends (any radius) diminishing peaces or tapers (large bore measured) with oval access door complete all as specified and directed. |
| 120 | S&F cast iron floor trap , 75mm dia with grating incluing jointing to waste pipe fixed in cement concrete 1:2:4 type B1 using 20mm graded stone aggregate complete all as specified and directed. |
| 121 | S&F 100mm dia cast iron branch pieces, single (equal or un-equal), ordinary or inverted (spigot or socket type) or with parralel branches with oval access door complete all as specified and directed. |
| 122 | S&F 100mm dia of CI 'P' Trap long with gratint including jointing to waste pipe fixed in cement mortar 1:2:4 type B-1 complete all as specified and directed. |
| 123 | S&F 100mm bore cast iron cowl complete all as specified and directed. |
| 124 | S&F 75mm bore cast iron cowl complete all as specified and directed. |
| 125 | S&F pressed steel frame of size 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc (thickness of sheet shall be 1.25mm) and making good the wall with plaster in CM 1:6 complete all as specified and directed. |
| 126 | M&L for PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) for filling in bed block of hold fast etc complete all as specified and directed. |
| 127 | M&L for preparing newly plastered surfaces of walls and applying three coats of White wash on walls complete all as specified and directed. |
| 128 | M&L for preparation of new plastered wall surface and finishing wall with two coats of Acrylic smooth exterior paint of required shade : (applied @ 1.67 ltr / sqm over and including priming coat of exterior primer applied @ 2.20 kg / 10 sqm complete all as specified and as directed. |
| 129 | M&L for preparing of new wooden surface exc 10cm in width or grith and applying two coat of synthetic enamel paint over one coat of pink primer complete all as specified and as directed. |
| 130 | M&L for preparing of new steel surface exc 10cm in width or grith and applying two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 131 | M&L RCC hume pipe septic tank designed to carry sewage and sludge water, excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc, complete for 10 users complete all as specified and directed. |
| 132 | Construction of soakage well for 1.2 m dia & 3 m deep including excavation in any type of soil, PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in footing brick honey comb / solid masonry in cement 1:4, RCC cover slab filled with brick bats including intercepting chamber screen chamber and disposal of soil complete all as specified and directed. |
| 133 | M&L for concrete bed to drain pipes (150 dia) including packing under, and haunching against the sides of pipes after they are laid and tested in cement Concrete 1 : 3 : 6 type C-2 complete all as specified and directed. |
| 134 | M & L for 150mm dia (internal) DWCPE pipes laid in trenches & jointed complete all as specified and directed. |
| 135 | Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6m mean radius built in in CM 1:4, complete all as specified and directed. |
| 136 | Brick work with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:6, complete all as specified and directed |
| 137 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick any type of soil, complete all as specified and directed. |
| 138 | Cutting in to existing manhaoles for connecting new drains, making good to pipe and rendering, cutting out existing benching for as specified dia of pipe 150mm complete all as specified and directed. |
| 139 | M&L Non skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc set and jointed in neat cement slurry /paste and pointed in white or coloured cement to match including 10mm thick backing coat in CM 1:4 complete all as specified and directed. |
| 140 | S&F Anodised aluminium frame for doors, windows, ventilators and partitions (fixed portion) with one or more rebats including joining cleat for fixing etc. complete all as specified and directed. |
| 141 | S&F Anodised aluminium window and ventilator shutters side hung type without sash bar aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, aluminium snap beading , screws, anodised aluminium fittings such as peg stay 150mm long (01 No), hinge type B-21, 100mm long (02 Nos), suitable handle 125mm (01 No) in each door complete all as specified and directed. |
| 142 | S&F 3mm thick figured glass , pin head type, glazing with putty in ventilator complete all as specified and directed. |
| 143 | S&F Vitreous China wash down water closet pan (pedestal pattern), white (excluding flushing cistern ) including connection to drain (or outgoing pipe) and to flushing pipe , antisyphonage pipe , pvc cover sheet in same colour etc complete all as specified and directed. |
| 144 | S&F Vitreous China valveless, syphonic action type, flushing cistern, low level white with inlet, ball valve, float and handle including brackets suitable for wall hung EWC complete all as specified and directed. |
| 145 | S&F counter Wash hand basin vitrous China (oval type) size size 560 x 410 mm including 32mm chromium plated waste couplingincluding brackets, & PVC waste pipe/bottle trap including making connection and fixed in position complete all as specified and directed. |
| 146 | S&F 15mm bore Swan neck fancy type Pillar taps, cast copper alloy with capstan head , chromium plated screwed down high pressure, with or without lettered Hot ot Cold with long screwed shanks and flynuts screwed for iron pipe complete all as specified and directed. |
| 147 | S&F Vitreous China Urinals partition white of size 310 x 700mm terminating about 40cm above floor line omplete in all respect complete all as specified and directed. |
| 148 | S & F PVC connection 15 mm size with PTMT nuts of length 450 mm of approved quality complete all as specified and directed. |
| 149 | S&F 600x450mm bevelled edge mirror of slected quality glass mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plug with chromium plated brass screws and cup washers complete all as specified and directed. |
| 150 | S&F tubular towel rail brass chromium plated 20mm dia, D type, 600mm long between flanges complete all as specified and directed. |
| 151 | S&F for jet suitable for water closet pedastal pattern with pvc conection pipe complete all as specified and directed. |
| 152 | S&F 1000 litres capacity Rotational moulded polyethylene in white colour water storage tanks triple layer (cylindrical vertical with closed top) hoisted and fixed in position, including over flow and drain out pipe complete complete all as specified and directed. |
| 153 | S&F 20 mm bore dia of pipe Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 20mm -210 gms ) complete all as specified and directed. |
| 154 | Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in any type of soil, complete all as specified and directed. |
| 155 | M&L for Plain Cement concrete type C-2, 1:3:6 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete, complete all as specified and directed. |
| 156 | M&L for 25mm thick sand cusioning layer under interlocking paver block including watering and consolidation complete all as specified and as directed. |
| 157 | M&L for 80 mm thick machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of M-40 Grade with grey cement and pigments complete all as specified and directed. |
| 158 | M & L for Point wiring with multi-stranded copper conductor, single core, PVC insulated and unsheathed FRLSH cable, including PVC insulated unsheathed multistranded copper conductor single core FRLSH cable as earth continuity conductor to common earth and connected to earth dolly with GI terminal boxes, modular frame & cover plate (suitable for modular switch/sockets) for the following: - |
| 159 | One light / fan point controlled by one 6amp switch & fan regulator etc. with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified complete all as specified and directed. |
| 160 | One light / fan point controlled by one 6amp switch & fan regulator etc. with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit complete all as specified and directed. |
| 161 | One Socket outlet three pin, 6 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit complete all as specified and directed. |
| 162 | One socket outlet three pin, 5/15 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit complete all as specified and directed. |
| 163 | M & L for point wiring with two run of 2.5 Sqmm (nominal area) PVC insulated, unsheathed multi standed copper conductor cable FR-LSH in and including concealed PVC conduit 20mm dia medium grade ISI marked, steel terminal sunken boxes and 3 mm thick phenolic laminated sheet top cover for sunken boxes flush to surface with one run of PVC insulated unsheathed 2.5 Sqmm copper conductor cable FR-LSH as earth wire connected wire common earth dolly complete including cutting, casing the surface and then making good the same complete all as specified and directed. Note :- Switchs, sockets etc shall be measured and paid for separately under respective items of schedule. |
| 164 | One light/ fan /bell point controlled by one 5 Amps one way switch |
| 165 | One Socket outlet point 3 pin 5 Amps on same board with other switches |
| 166 | One socket outlet 3 pin 5 Amps on independant board. |
| 167 | All as per item No 188 here in before but for one socket outlet 3 pin 15 Amp complete all as specified and directed. |
| 168 | Note for serial item No 158 to 159.04:-1. Switch(es) & socket(s) shall be measured & paid for separately under respective item of Schedule 'A'. 2. GI boxes shall be fixed flush in position with cement mortar (1:4) complete all as directed. |
| 169 | S&F Switch modular type single pole, one way, 6 Amp, one module, complete all as specified and directed. |
| 170 | S&F Switch modular type single pole one way, 16 Amp, one module, complete all as specified and directed. |
| 171 | S&F Socket outlet modular type, multipurpose, 2/3 pin, single pole one way, 6 Amp, two module, complete all as specified and directed. |
| 172 | S&F Socket outlet modular type multipurpose 2/3 pin single pole one way 6/16 Amp, two module, complete all as specified and directed. |
| 173 | S&F Ceiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as specified and directed. |
| 174 | S&F sheet metal encloser double door 04 way SPN 240V ISI marked IP 43 complete with neutral and earth link and bus bar complete made out of CRCA steel sheet Factory made including blanking plate for unused module complete all as specified and directed |
| 175 | S&F sheet metal encloser double door 08 way SPN 240V ISI marked IP 43 complete with neutral and earth link and bus bar complete made out of CRCA steel sheet Factory made including blanking plate for unused module complete all as specified and directed |
| 176 | S&F in repair sheet metal encloser double door 12 way SPN 240V ISI marked IP 43 complete with neutral and earth link and bus bar complete made out of CRCA steel sheet Factory made including blanking plate for unused module complete all as specified and directed |
| 177 | S&F MCB 6-32 Amp SP 10 KA ‘B’ series complete all as specified and directed. |
| 178 | S&F MCB 6-32 Amp SP 10 KA ‘C’ series complete all as specified |
| 179 | S&F MCB 40-63 Amp 240V SPN 10 KA ‘C’ series complete all as specified |
| 180 | S&F in replacement sub main two single core PVC copper conductor unsheathed wire multi stranded 6 sqmm along with earth wire 6.0 sqmm copper conductor single core wire connected by common earth in medium grade PVC conduit 25mm complete all as specified and directed.(Note :- two lengths of 6.0 sqmm cable and one length of 6.0 sqmm earth cable alongwith 25mm pvc conduit will be measured as one running length) |
| 181 | S&F wall mounted extruded Aluminium/polycarbonate integrated LED batten fixture with tube 1.2 m, 20watt, 1.2 m 3000/6500K,efficacy not less than 90 lumen/watt, extruded Aluminium/polycarbonate, PC diffusor and integrated inbuilt driver complete complete including making connection complete all as specified and directed. |
| 182 | S&F wall mounted LED batten fitting 1X10 watt, 6500K, 2 ft complete with decorative ultra slim square profile LED lighting fixture with extruded polycarbonate enviroment friendly, energy efficient complete with all light fittings connection all as specified and directed. |
| 183 | S & F LED light fitting 1x20 watt, 220 V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 184 | S & F LED mirror fitting 1 x 10 watt including LED tube complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks of through holes. The system wattage of fitting should not be more than 5 watt + 10% surge protection of minium 3.5KV power factor should be more than 0.95 cool white colour total harmonic distoration (THD) should not be more than 10% lumen output should not be less than 1000 lumens total input voltage range 140-280v AC, colour temperature 6000K complete all as specified and directed. |
| 185 | S&F angle lamp holder polycarbonate type with back plate complete all as specified and directed. |
| 186 | S&F LED 7W Lamp base B-22 6500K, efficacy not less than 90 lumen/watt complete all as specified and directed. |
| 187 | Taking down carefully existing exhaust fans from site, deposite safely to E/M yard store or as directed place, complete all as specified and as directed. |
| 188 | Fixing only exhaust fan and connecting up including provision of cable from ceiling rose/connector to fan complete all as specified and directed. |
| 189 | Supplying, Laying ,and testing in of XLPE insulated armoured heavy duty electric cable of the size 25 Sqmm 2 core following size ,1100 Volts grade , with stranded aluminium conductor served with aninner sheathing of PVC tape armoured with GI wire and over all PVC sheathed in laid trenches/ passing through pipe/duct/road crossing/surface of wall/in hume pipe etc including fixing hardware,clamps,gland, thimble and making good the damaged surfaces etc complete all as specified and as directed. |
| 190 | Supply and spread river sand 8cm thick to required width at bottom and 15cm thick on top for cable cushioning (total thickness of sand cushion will be measured after hand punning and shall be not less than 18 cm thick in layer) complete all as specified and as directed. |
| 191 | Supplying and laying un-reinforced precast concrete cable cover, class LV, Type-1, flat, size 250mm x 150mm x 40mm, ISI marked, laid flat across the cable length complete all as specified and as directed. |
| 192 | Removal of surplus excavated soil not exc 50 mtrs and deposting where directed at level not exc 1.5 mtr above the starting point complete all as specified and as directed. |
| 193 | S&F RCBO for earth Leakage, Over Load and short Circuit Protection 230V 32 Amp AC Type 10 KA Four Pole 30mA ISI marked complete all as specified and directed. |
| 194 | S&F LED street light fitting 35 Watt 230V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrossion resistant complete with IP 65/66 protection including fixing with GI/MS bracket made out of suitable size of light grade tube upto 1.2 mtr length bent to shape with 02 sets of MS clamps made out of minimum 3 mm MS flat iron with suitable bolt and nuts complete with making connection complete all as specified and directed |
| 195 | M & L for earthing with galvanized steel plate electrode 600 x 600 mm x 6 mm size directly burried in ground vertically to earth pit not less than 2.25 meter deep below normal ground level with top edge of the earth plate not less than 1.5 m below normal ground level surrounded with coal dust and common salt filling in alternative layers of 15 cm thick each connected to and including GI earth wire 4 mm dia by means of nuts, bolts, check nuts & washers etc connecting to earthing test point, main switch board and including 15 mm dia GI pipe light grade for protection of earth lead from earth plate to distribution board and 20 mm dia GI pipe medium grade connected with funnel having wire mess for watering purpose including necessary excavation and earth work, PCC (1:2:4) type B-1 (using stone aggregates) for earthing pit, 10mm thick cast iron cover with angle iron frame all as specified and shown in electrical plate No 3 of SSR Part-I and testing on completion including replacement of old unserviceable. |
| 196 | S&F of metallic exhaust fan of sweep 300mm along with metallic louver complete including cutting of wall, making of proper hole sufficient to fix exhaust fan and smoothing of the surface before fixing of exhaust complete all as specified and as directed . |
| 197 | Supply and fixing & testing storage type water heater (geyser) electrical operated 230/240 volts 25 ltr capacity, BEE 5 star rated complete with all safaty equipment and accessaries such as safety valve, thermostat, plug top, etc. required for proper functionality and including electric/earth connections and carrying out grounting and complete installations with mounting bolts, nuts complete all as specified and directed. |
| 198 | S&F single pole and neutral enclosure 240V with a two pin and earth plug and socket complete with one single pole MCB 20Amp for AC connection complete all as specified and direcetd |
| 199 | S&F exhaust fans AC single phase 230/240v of size 300mm sweep with louver complete all as specified and direcetd Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail