| 1 | Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; manhole cover; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290-0 or Fe 165-0, as in repair all as specified and directed. |
| 2 | Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour, having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, including cutting out grrove in wall, insert sheet under groove and pack with CM 1:3 complete all as specified and directed. |
| 3 | Two coats of synthetic enamel paint on steel and iron surfaces over one coat of red oxide primer on surfaces over 10 cm width or girth including preparation of new surfaces complete all as specified & directed. |
| 4 | Taking down chowkats or frame exc. 1.5 Sqm and n exc 4 Square metre with shutters, without taking off shutters from the frame, complete all as specified and directed. |
| 5 | Factory made pressed steel frames of profile width 105mm x 60mm fabricated from 1.25 mm thick sheet, for doors with one or more rebate including necessary fixing lugs, hinges, lock strike plate, etc. & one shop coat of primer, including filling of PCC 1:3:6 complete all as specified and directed. |
| 6 | Factory made second class hard wood 35mm thick Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated, all as specified and directed. |
| 7 | preparation of new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 8 | D' type, 150mm Extruded aluminium alloy handle fabricated type, complete all as specified and directed. |
| 9 | 150 mm size aluminium , barrel tower bolt of extruded section and complete all as specified and directed. |
| 10 | Aluminum alloy, anodized, sliding door bolt 250mm long hasp , staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy and fixed complete all as specified and directed. |
| 11 | Taking down cement plaster from brick walls or concrete surfaces including raking out joints, hacking out for key, scrubbing down with water complete all as specified and directed and removing rubbish etc. complete all as specified and directed. |
| 12 | Dubbing out average 20mm thick on irregular faces of walls, exposed reinforced surfaces, in Cement and Sand mortar 1:4 complete all as specified and directed |
| 13 | Rendering 5mm thick in cement mortar 1:3 on fair faces of concrete surfaces as in ceilings , finished fair and smooth, complete all as specified and directed. |
| 14 | Rendering 15mm thick in Cement and Sand mortar 1:4 over fair faces of brick / concrete ,finished even and smooth without using extra cement, including using water proofing compound as per manufacturers instruction, including necessary scaffolding & safety arrangement for plaster upto & including 4 storey building complete all as specified. Note : WPC shall be measured and paid separately. |
| 15 | Supply only integral water proofing compound (ISI Marked) complete all as specified & directed. |
| 16 | Rendering 15mm thick in Cement and Sand mortar 1:6 over fair faces of brick/concrete surfaces ,finished even and smooth without using extra cement, complete all as specified and directed. |
| 17 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on wall (smart periodical) complete all as specified and directed. |
| 18 | Finishing walls with Acrylic Smooth exterior paint of required shade, on new work/ surface prepared and applying Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm, complete all as specified and directed. |
| 19 | Two coats of oil bound distemper on ceiling surfaces over a caot of primer including preparation of new plastered surfaces complete all as specified and directed |
| 20 | Two coats of oil bound distemper on ceiling surfaces including preparation of old surfaces complete all as specified and directed. |
| 21 | Taking up or down steel tubing and connections 20mm bore, complete all as specified and directed. |
| 22 | Taking up or down steel tubing and connections 25mm bore ,complete all as specified and directed. |
| 23 | 20 mm bore Galvanized Steel tubes, medium grade including all fittings for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors, complete all as specified and directed. |
| 24 | 25 mm bore Galvanized Steel tubes, medium grade including all fittings for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors, complete all as specified and directed. |
| 25 | 25mm bore Union, brass to connect iron to polyethylene and fixed, fixed as in repairs complete all as specified and directed. |
| 26 | Cutting holes of superficial area n.exc 150 Sqcm and depth upto 30 centimeter into or through brick wall built in cement mortar/ RCC Chajjas, surfaces etc with core cutting method and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required after fixing of mild steel pipe sleeves in wall / slab as required complete all as specified and directed. |
| 27 | PVC (SWR) rain water pipe, 110mm bore, single/ double socketed in any length , having minimum density 6 Kg/cm2, laid in trenches orin floor , fixed as in repair complete all as specified and directed. |
| 28 | PVC (SWR) rain water pipe, 110mm bore, single/ double socketed in any length with rubber ring joints, having minimum density 6 Kg/cm2 fixed to walls with MS clamps made out of flat iron of size 25mm x 3mm including nuts bolts etc, fixed as in repair complete all as specified and directed. |
| 29 | 110 mm bore PVC (SWR) bends with acceess door complete, fixed as in repair all as specified and directed. |
| 30 | 500 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) triple layered, screwable lid, hoisted and fixed in position, including PTMT ball valve 20mm bore & PTMT tank nipple, etc, fixed as in repairs, complete all as specified and directed. |
| 31 | Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 32 | Brick work with sub class ‘B’ bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:6 complete all as specified & directed. |
| 33 | Brick work with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified & directed. |
| 34 | Plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate cast in situ in lintels up to 1.5 m clear span, cills, steps, seismic and other similar bands, hold fast, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, water through and the like including weathering, slightly rounded or chamfered angles and throating including use of form work (straigth or curved) complete all as specified & directed by Engineer-in-charge. - NOTE : (i) The unit rate include for use of form work (straight or curved). (ii) Reinforcement if any shall be measured and paid separately. |
| 35 | Demolition of mud phuska as in roof of any thickness incl plastering and leeping etc (whether full thickness removed or only a part thereof), removal of debris complete all as specified & directed. |
| 36 | Dismantling of existing brick tiles or terracing tiles single layer on roof grouted in cement mortar including removal of any existing treatment complete all as specified & directed. |
| 37 | 40mm thick average thickenss PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in roof padding, roof kerbs rounded or chamfered on edges complete all as specified and directed. |
| 38 | 10mm thick rendering in Cement and Sand mortar 1:4 over roof slab finished even and fair mixed with water proofing compound as per manufacturer's instruction complete all as specified.Note : WPC shall be measured and paid separately. |
| 39 | 3mm thick Atactic polypropylene polymer (APP) based polymeric membrane minimum weighing 3.6kg/sqm and reinforced with polyester non woven fabric (weight not less than 150 gm/sqm) laid over a coat of bitumen primer @0.40L/Sqm by same membrane manufacturer of density 0.87 to 0.89 kg/L at 25° C temperature and viscosity 70 to 160 CPS. The membrane shall be laid using butane torch and sealing all joints etc after preparing the surface on roof slab / complete parapet height / top /15cm down on external wall as per standard practice and as per manufacturer instructions including dismantling of existing felt /treatment, complete all as specified & directed. |
| 40 | Two coats of aluminium paint over APP based polymeric memebrance, including preparation of top surface over roof complete all as specified & directed. |
| 41 | Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner complete all as specified and directed. |
| 42 | Demolition of stone slabs and tiles of any description or thickness in floors laid, bedded and pointed in any mortar including disposal of demolished material complete all as specified and directed. |
| 43 | Taking down, chipping and removing the loose, split, damaged cement concrete, cement mortar surfaces of RCC columns, beams, walls, chajjas etc and exposing the reinforcement, wire brushing and cleaning the exposed steel reinforced bar, apply rust remover over the cleaned reinforced bar surface wash the re-bar with clean water for removing all rusts fromthe old re-barsurfaces, fixing new reonforcement for strengthen the members as required, applying two coats of epoxy zinc primer on new and old steel surfaces, saturate the substrate with water applying one coat of polymer modified cement and quartz sand mortar in CM 1:3 mix, 40mm average thick in two coats, with and including polymer @10% by weight of cement, including erecting and dismantling steel scaffolding for carrying out the work upto height of 10 metre (Appx) complete all as specified and as directed.Note:- Make;- Dr fixit/ Sunanda/chemestik/fosrock. |
| 44 | 18 to 20mm thick Green marle(table rubbed and polished) as in lining (veneering to wall) riser, skirting/ dado over and including 12mm thick cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. compelte all as specified and directed. Please Enable Macros to View BoQ information |