| 1 | Dismantling Single layer Mangalore Pattern or similar tiles in roofing and rubbish off the premises complete all as specified and as directed. |
| 2 | Material and labour for roof tiles Mangalore pattern interlocking at side joints, laid dry in roofing complete all as specified and as directed. |
| 3 | Material and labour for ridge or hip tiles to suit Manglore pattern of roofing tiles,bedded and jointed in cement mortar (1:4) etc complete all as specified and as directed. |
| 4 | Dismantling steel work including doors, gates, rolling shutter, weldmess but excluding framed trusses etc complete all as specified and as directed. |
| 5 | S & F in repair Rolled steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates of Fe-290 ( Gde E165 ) complete all as specified and as directed. |
| 6 | M&L for mild steel framed work such as grill, grating etc with ends of bars shouldered or rebated or forged into spike framed guard bars barred iron doors, ladders, framed baluster, walk way, railing; frame work, including pintle hinges, stops, hand-made sliding bolts etc,sliding channels for sliding of gate and similar work conforming to Fe 290 Gde-E-165 complete all as specified & as directed. |
| 7 | M&L for preparation of New steel surfaces of any description over 10cm girth or width and applying Two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 8 | Dismantling plain or corrugated steel sheeting , any gauge or any thickness, as in roof coverings complete all as specified and as directed. |
| 9 | Supply and fix 0.63mm thick galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with 'J' Bolts and washers, in roofs, walls etc with grade of zinc coating 120gms/ Sqm complete all as specified and as directed. |
| 10 | Supply and fix in repairs 0.56mm thick plain, Aluminium sheeting, alloy 31000H4 in ridges, hips, valley gutter, crumple joint, drip and straight flashing (length and girth as fixed) complete all as specified and as directed. |
| 11 | M&L for PCC (1:2:4) type B1 (using 20mm graded stone aggregates) as in roof kerbs or mud stops rounded or chamfered on edges and as in Coping and similar work complete all as specified and as directed. |
| 12 | M&L for Eves/Weather Boarding of AC Sheet 12 to 15mm thick, any size and shape including taking down existing board complete all as specified and as directed. Make: Shera wall/Everest/ V-board/Charminar or Eqvt. |
| 13 | Taking down shutters of any description area exc 1.5 Sqm but not exc 4 Sqm complete all as specified and as directed |
| 14 | M&L granite 18 to 20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platform and like over and including 15 mm thick screed bed of CM (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of any description or thickness laid bedded and pointed in cement mortar complete all as specified and as directed. |
| 15 | Labour only for full round moulding to 18 to 20mm thick granite slab complete all as specified and as directed. |
| 16 | S&F powder coated anodised aluminium work as in frame, doors, windows, ventilators including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings with one or more rebates including joining cleat for fixing etc (minimum thickness of powder coating 50 micron). complete all as specified and as directed. Note:Glass / wiremess shall be measured & paid separately. |
| 17 | S&F 4mm thick sheet glass, ordinary quality incl glazing in door/windows/partions complete all as specified and as directed. |
| 18 | S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed. |
| 19 | Demolition of cement concrete in ground floors , pavings, sunken floor etc (below or above ground level) and rubbish off from the premises complete all as specified and as directed. |
| 20 | M&L for Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in Hard/ Dense soil complete all as specified and as directed. |
| 21 | Removing excavated soil to a distance exc. 1.50 km but n exc. 5 km and depositing where complete all as specified and as directed. |
| 22 | M&L for Hardcore of Broken stone of gauge n. exc 63 mm deposited, spread and levelled in layers n exc 150 mm thick, watered and rolled / rammed to a true surface complete all as specified and as directed. |
| 23 | M&L for 80mm thick factory made glossy finish rubber moulded chamfered edge cement concrete paver block of M-40 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping complete all as specified and as directed |
| 24 | Material and labour for 75mm thick PCC (1:4:8) type D2 (using 40mm graded broken stone aggregate) as in sub base complete all as specified and as directed. |
| 25 | Material and labour for 75mm thick PCC (1:3:6) type C2 (using 40mm graded broken stone aggregate) as in plinth protection finishing the surface even and smooth without using extra cement including demolition complete all as specified and as directed. Note: Joint shall be cut at 3 to 4 meter distance |
| 26 | M&L for joint filling with polyurethane sealent of width 20mm and depth 1/3 of thickness of plinth protection complete all as specified and as directed. |
| 27 | M&L for Machine cut kota stone 20-25mm thick over cement screed bed 15mm thick in CM (1:4) laid and jointed with grey cement slurry and pointed with grey cement and pigment to match the shade of the slab including rubbing and polishing complete (mirror polish) as in flooring/steps /slabs complete all as specified and as directed. |
| 28 | M&L for Machine cut kota stone 20-25mm thick over 10mm thick backing coat in CM (1:4) laid and jointed with grey cement paste and pointed with grey cement and pigment to match the shade of the slab including rubbing and polishing complete (mirror polish) as in riser of steps/Skirting/dado and pillar complete all as specified and as directed. |
| 29 | M&L for Pre-cast cement concrete block masonry with solid blocks type C1, exc. 10 cm in width and setting in cement mortar 1:6, complete all as specified and directed |
| 30 | Taking down cement plaster on brick/ stone walling including raking out joints, hacking for key, scrubbing down with water etc complete all as directed. |
| 31 | Material and labour for rendering 20 mm thick in cement mortar (1:6) on fair faces of on stone wall or brick work or concrete surfaces and finished even and smooth without using extra cement all as specified and as directed. |
| 32 | Material and labour for preparation of New plastered wall surface and applying two coats of oil emulsion distemper over a coat of alkali reistant primer over a thin layer (1 to 1.5mm) complete all as specified and as directed. |
| 33 | M&L for 20mm thick cement plaster in CM 1:4 on brick/stone masonary concrete surfaces/chajjas/parapet finishing even and smooth without using extra cement with using water proofing compound @200 ml per bag of cement or as per manufactuer's instructions complete all specified and directed. (Note: Waterproofing compound shall be measured and paid separately under relevant item as supply only). |
| 34 | M&L for preparation of new plastered surfaces and applying two coats of weather proof exterior emulsion paint ('APEX' brand of Asian or equivalent brand of Berger/Shalimar) over a coat of primer on wall complete all as specified and as directed by Engineer-in-charge. |
| 35 | Supply only Liquid water proofing compound complete all as specified and as directed. |
| 36 | S&F for 1mm thick Steel Rolling shutter without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated complete but gear operated type with bevel gear box and crank handle all as specified and as directed Note: Mode of measurement of width shall be channel to channel of rolling shutter |
| 37 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. |
| 38 | Material and labour for point wiring using approved colour coding as per IS ,with multistranded copper conductor 1.5 Sqmm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade ISI-694 marked drawn through in and including heavy duty PVC concealed conduit including all accessories, Metal flush box of suitable module, with earth dolly, covered with twin colour (specified by Engr-in- Charge)modular white cover plate & frame after chasing in brick masonry walls etc for accomodating modular switches, sockets, regulators etc including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly, providing Copper cable sockets plate/ bottle type of adequate size at termination end of cable point wiring in DBs, switch boards, fittings fixtures all as specified and as directed for the following |
| 39 | One light / wall / exhaust fan point controlled by one, one way switch 6 Amps complete all as specified and as directed |
| 40 | One 5 pin socket outlet plug point, 6 Amps, controlled by one, switch on same board complete all as specified and as directed |
| 41 | One 5 pin socket outlet plug point, 6 Amps, controlled by one, switch on independent board complete all as specified and as directed |
| 42 | Description all as per 38 here-in before but using 2.5 Sqmm single core copper conductor FRLS cable of multistranded PVC insulated unsheathed 1100 Volts grade for one 6 pin socket outlet plug point,16 Amps independent including necessary running of 2.5 Sqmm PVC insulated multistranded copper conductor single core FRLS cable as earth continuity conductor along with wiring and connecting to earth dolly providing Copper cable sockets plate/ bottle type of adequate size at termination end of cable point wiring in DBs, switch boards, fittings fixtures all as specified and as directed |
| 43 | Supply and fixing Modular Switch - 6 Amps, Single pole one way, one module complete all as specified and as directed. |
| 44 | Supply and fixing Modular Switch - 16 Amps, Single pole one way, one module complete all as specified and as directed. |
| 45 | S & F Modular socket outlet multipurpose 6 Amps, 5 pin, 2 module, complete all as specified and as directed. |
| 46 | S & F Modular socket outlet multipurpose 16 Amps, 6 pin-shuttered type, 2 module, complete all as specified and as directed. |
| 47 | S & F Ceiling rose, 3 phase / PVC / polycarbonate, complete all as specified and as directed |
| 48 | Supply and fix in repair for wall mounted LED 18/20watts with lumens out put not less than 2000 lumens white/ warm white, box type (decorative) light fitting, 230 volts with extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver connector block etc complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED tube 4' x 20watts complete all as specified and as directed. Make: Halonix Cat part No HLB-03-18-CW-AL Bajaj Cat No. BCLAB 20W, JAQUAR Cat part No LGLZ01X020XN or equvalent of make Philips/ as approved. |
| 49 | S & F in repair for wall mounted 18 watts indoor Inverter batten with opal diffuser, IP 20, with 4 hrs back up with out put of 1800 lumens , box type (decorative) light fitting, 230 volts with extruded aluminium heat sink provided for efficient heat dissipation and intregrated electronic driver connector block etc complete with all accessories internally pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED tube 4' x 18 watts complete all as specified and as directed. Make :- Halonix Cat part No. LED INVERTER BATTEN HLB-08-18-CW-INV or equivalent Philips |
| 50 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection completecomplete all as per Make JAQUAR, Bajaj, Philips, Havells as approved. |
| 51 | S & F for Metal body exhaust fan, AC single phase, 240 V of size 450 mm sweep with louvers including necessary connection and replacement of flexible copper cable from ceiling rose and taking down of old unserviceable fan complete all as specified and as directed of make Bajaj/ Usha/ Havells or equivalent. |
| 52 | S&F MCCB DB VTPN 4 way double door sheet metal enclosure for 100 Amps 4 pole MCCB (ICS = ICU= 100%) Incomer comprising OEM/manufacturer specified bus bar, 415 Volts, 50 Hz , 160 Amps bus bar and neutral link complete including inserting in wall all as specified. MAKE:- Havells Cat No DHDLVDRWGOF004, LEGRAND/SCHNEIDER/ L&T |
| 53 | S & F sheet metal enclosure MCB DB SPN 8 way with 100 Amps rated bus bar 240 Volts double door with magnetic locking system including necessary provision for inserting the DBs in wall by cutting the brick/ stone masonary etc and making good of disturbed surface to match the existing colour of wall complete all as specified and as directed |
| 54 | S & F MCCB FP 415 volts of Breaking Capacity 25 kA with Thermal Magnetic Release without enclosure suitable for fixing on DB of capacity 63 Amps with extended terminals complete all as specified. L&T/C & S/Schneider/ABB/Havells |
| 55 | S & F for MCB triple pole and neutral 415 Volts, 40 Amps, 10 KA. (ICS=ICU=100%) |
| 56 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SP 5 To 32 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed |
| 57 | Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SPN 32 AMP and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed |
| 58 | S & F heavy duty industrial grade electrical circular socket connector outlet 5 holes (03 phase + neutral + earth) mounted inside a metal enclosure suitable for high power application of rating 32 Amps including necessary provision for fixing the enclosure in wall etc complete all as specified and as directed. Make : Havells, L&T, or equivalent |
| 59 | S & F submain wiring with 4 single core (FRLS) PVC insulated unsheathed multistranded flexible copper conductor cable, of 6.0 Sqmm and two single core 6.0 Sqmm flame retardent low smoke (FRLS) PVC insulated, unsheathed, multistranded, flexible copper cable as earthing lead , all as per IS 694/1990 drawn through including PVC conduit and conduit accessories heavy duty ISI marked, providing Copper cable sockets plate/ bottle type of adequate size at termination end of cable point wiring in DBs, switch boards, fittings fixtures all as specified and as directed complete all as specified and as directed. Note :- ( Four runs of main copper wire, two run of earth wire cable & PVC Casing caping/ conduit shall be measured together as one length). |
| 60 | S & F submain wiring with 2 single core (FRLS) PVC insulated unsheathed multistranded flexible copper conductor cable, of 4.0 Sqmm and one single core 4.0 Sqmm flame retardent low smoke (FRLS) PVC insulated, unsheathed, multistranded, flexible copper cable as earthing lead , all as per IS 694/1990 drawn through including concealed in stone masonary PVC conduit and conduit accessories heavy duty ISI marked, providing Copper cable sockets plate/ bottle type of adequate size at termination end of cable point wiring in DBs, switch boards, fittings fixtures all as specified and as directed all as specified and as directed complete all as specified and as directed. Note :- ( Two runs of main copper wire, one run of earth wire cable & PVC conduit shall be measured together as one length). |
| 61 | All as per item No 57 but of size 1.5 Sqmm |
| 62 | All as per item No 57 but of size 2.5 Sqmm |
| 63 | M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion |
| 64 | Note : 1. Performance security:- Refer Condition 22 of Special Conditions. 2. Quoted Contract Sum shall be arrived at after deducting the amount of Credit Schedule (refer Schedule of Credit in pdf form for quantity, rate and amount etc.) for old unserviceable materials retrieved from site. Please Enable Macros to View BoQ information |