Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 03-06-2026 | Amendment in tender date | Date | 15-06-2026 |
| 2 | 18-05-2026 | Amendment in dates | Date | 10-06-2026 |
| Sl. No. | Item Description |
| 1 | B/R Works |
| 2 | Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exceeding 1.5 sqm each complete all as specified and directed |
| 3 | Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc 1.5 sqm but not exc 4 sqm each complete all as specified and directed |
| 4 | Taking up or down steel tubing 15mm bore and connections including removing from site complete all as specified and directed |
| 5 | Taking up or down steel tubing 20 mm bore and connections including removing from site complete all as specified and directed |
| 6 | Supply and laying 15mm bore tubes, galvainzed steel, medium grade, with all fittings and fixed complete on walls (concealed type) and ceilings or laid in floors complete all as specified and directed.Note: Cutting chases and making good shall be measured and paid seperately. |
| 7 | Supply and laying 20 mm bore tubes, galvainzed steel, medium grade, with all fittings and fixed complete on walls and ceilings or laid in floors complete all as specified and directed. |
| 8 | Cutting chases Stone concrete blocks pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing etc., and making good, cutting not exc 10 cm girth for stone walls complete all as specified and directed. |
| 9 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 10 | M & L for rendering 10 mm thick in CM 1:6 on stone masonry surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 11 | M & L for rendering 15 mm thick cement plaster in two layers (10+5) with bottom layer 10mm thick in CM 1:6 and top layer 5mm thick in CM 1:4 mixed with liquid water proofing compound ISI marked @ 3% by weight of cement or as per manufacturers instructions finished even and smooth without using extra cement up to any height complete all as specified and directed.Note : Water proofing compound shall be measured and paid seperately. |
| 12 | M & L 5 mm thick plastering in CM 1:3 finished even and smooth without using extra cement on concrete surface of ceilings/chajja complete all as specified and directed. |
| 13 | M & L for preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of alkali-resistant primer 2 mm thick wall care putty on plastered surfaces by mechanical means using suitable tools and plants complete all as specified and directed. |
| 14 | M & L for preparation of new decorated plastered or unplastered surfaces of walls and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces by mechanical means using suitable tools and plants as per manufacturers instructions complete all as specified and directed. |
| 15 | M & L for three coat of white wash on new surface of ceiling including preparation of new surfaces by mechanical means using suitable tools and plants as per manufacturers instructions complete all as specified and directed |
| 16 | M & L for preparation of old plastered or unplastered surfaces of ceiling and applying one coat of white wash by mechanical means using suitable tools and plants as per manufacturers instruction complete all as specified and directed. |
| 17 | M & L for complete removal of old treatment by mechanical means from walls and applying one coat of primer, 2 mm thick wall putty and sanding on plastered surfaces prepatatory to distempering and applying two coats of oil emulsion distemper white or tinted over by pump roller applicator by mechanical means using suitable tools and plants as per manufacturers instruction complete all as specified and directed. |
| 18 | M & L complete removal of old treatment by mechanical means from walls and making good the holes, patches with putty and cement mortars (1:4) as required and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces by mechanical means using suitable tools and plants as per manufacturers instructions complete all as specified and directed. |
| 19 | M & L for preparation of old painted steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed. |
| 20 | S & F kitchen cabinet in required sizes at site made out of 18 mm thick WPC Board (plain colour) of standard grade density 650 KG/CBM consisting of carcase 18 mm thick WPC sheet & provision of shutters made out of 18 mm thick WPC sheet all required brackets 5.5\\" screws etc. The panels shall be fabricated using adhesive and screws where ever required. All the edges shall be covered with 2mm edge bonding tape or 90 deg edge bent finish as per make and specification mentioned as per drawing and specification approved by GE complete all as specified and directed. |
| 21 | S & F SS 304 grade soft-close, slow-motion, full overlay hinges (cup type of diameter 35 x 11.5 mm and maximum opening 105 degree), fixed to chowkhat complete all as specified and directed. |
| 22 | S & F nickle matt 100 mm handles for kitchen cupboard complete all as specified and directed. |
| 23 | S & F pressed steel frames 105 X 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete all as specified and directed. |
| 24 | S & F pressed steel frames of size 125 X60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete all as specified and directed. |
| 25 | M & L for cement concrete Type C-1 1:3:6 (20 mm graded aggregate) for filling the chowkat etc complete all as specified and directed. |
| 26 | S & F framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe-290, Gde-E-165 complete all as specified and directed. |
| 27 | S & F 35 mm thick factory made flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides as per manufacturing instructions complete all as specified and directed. |
| 28 | S & F 35 mm thick factory made, second class hard wood skeleton shutters, open rebated and prepared to receive glass, gauze etc (without sash bars ) edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR Part-I section 8 clause 8.24 (a) kiln seasoned and chemically pressure treated supplied and fitted to chowkats complete all as specified and directed. |
| 29 | S & F Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame including fixing with using anchor bolt as per manufacturing instructions complete as specified by the manufacturer and as directed. |
| 30 | S & F 30 mm thick Fiber Glass Reinforced Plastic (FRP) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table 3 of IS: 14856 complete all as specified by the manufacturer as directed . |
| 31 | M & L for preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described priming with red oxide and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 32 | M & L for preparation of new wooden surfaces of any description, over 10 cm in width or girth, not otherwise described priming coat with pink primer and applying two coats of synthetic enamel paint complete all as specified and directed. |
| 33 | Cutting holes in brick walls in cement mortar for inserting holdfasts and making good dismantled portion with cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required exc. half brick but not exc. one brick complete all as specified and directed. |
| 34 | S & F 150 mm long aluminium, anodized, barrel tower bolts of extruded section and fixed all as specified and directed. |
| 35 | S & F 200 mm long aluminium, anodized, barrel tower bolts of extruded section and fixed all as specified and directed. |
| 36 | S & F 250 mm long aluminium alloy anodized sliding door bolt with hasp staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed. |
| 37 | S & F for 100 mm long butt hinges, medium weight stainless steel complete all as specified and directed. |
| 38 | S & F extruded aluminium alloy handles, fabricated type, anodized, of size 150mm complete all as specified and directed. |
| 39 | S & F 300 mm, mild steel, ordinary rat rail rod pattern springs including roller and roller plate complete all as specified and directed. |
| 40 | S & F floor door stopper, with 150 mm long cover plate, double leg of aluminium alloy body and tongue, anodized, with hard drawn steel spring, fixed in floor complete all as specified and directed. |
| 41 | Welding in repairs exc. 2.5 cm & n.exc. 5 cm in length & thickness of metal n.exc. 6 mm complete all as specified and directed. |
| 42 | S & F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.4 mm & fixed with suitable fixing to aluminium window and skelton shutter complete all as specified and directed. |
| 43 | S & F in repairs vitreous china wash basin (for counter top), white or coloured, size 495x365x140 mm, brass chromium plated perforated waste coupling/ fittings 32 mm dia with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed and bottle trap 300mm complete all as specified and as directed. |
| 44 | S & F in repairs single mirror bath room cabinet moulded body and framed (made from strong and fine quality ABS plastic) with hinged door of size 16 \\" x 12 \\" x 6 \\" white or ivory colour fixed on wall with appropriate rawl plugs complete all as specified and directed. |
| 45 | Disconnecting existing tanks of any description exc. 250 ltrs and n.exc. 500 ltrs capacity and removing from site to store complete all as specified and directed. |
| 46 | S & F 500 litres capacity rotational moulded HDPE water storage tank (cylindrical vertical with closed top, painted with suitable white coloured heat protective paint, hoisted and fixed in position all as specified in SSR Part-I, connecting up pipes including 20 mm bore plastic ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight of ball valve - 210 gms) complete all as specified and directed. |
| 47 | S & F in repair sink made of stainless steel 1.00 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm, bowl size 410mm x 330mm x 160mm and PVC waste pipe of 40mm bore of suitable length, complete all as specified and directed. |
| 48 | S & F in repairs stainless steel plate rack 0.63mm thick of standard pattern of size 750x600x250 mm complete all as specified and directed |
| 49 | S & F in repairs vitreous china squatting pan, ‘Orissa’ pattern, size 580 mm x 440 mm, white with integral foot rests, including PVC 'P' trap, embedded and set in PCC 1:4:8 type E-2 and making good to floor including removing rubbish complete all as specified and directed. |
| 50 | S & F in repairs PVC valveless, syphonic action type, flushing cistern, low level, dual type 10 litres capacity, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed. |
| 51 | S & F in repairs 15 mm bore long body fancy type bib taps, cast copper alloy, chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule long body (Minimum weight 15mm - 450 gms) complete all as specified and directed. |
| 52 | S & F in repairs, 15 mm bore stop valve, fancy type, chromium plated with long shank and cup, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions (Minimum weight 15mm - 400 gms) complete all as specified and directed. |
| 53 | S & F in repairs 15 mm bore stop valve, fancy type, chromium plated with long shank and cup (concealed type), screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions (Minimum weight 15mm - 450 gms) complete all as specified and directed. |
| 54 | S & F in repairs 20 mm dia gun metal globe or gate valve with iron wheel head screwed both ends for iron pipes complete all as specified and directed. (Minimum weight 15mm - 450 gms) |
| 55 | S & F in repairs brass chromium plated shower rose of 125 mm size with swivel joint with CP arm fixing to steel pipe or union complete all as specified and directed. (Minimum weight 15 mm - 235 gms) |
| 56 | S & F in repairs PVC connection 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed. |
| 57 | S & F in repairs brass chromium plated tubular towel rail including brackets (two nos per towel rail), 20 mm dia, D type, 60 cm long between flanges complete all as specified and directed. |
| 58 | S & F in repair SS grating 100 mm dia cockroach trap type with or without hole complete all as specified and directed. |
| 59 | S & F in repairs Stainless steel Towel Ring 200 mm fixed with and including Chromium plated brass screws complete all as specified and directed. |
| 60 | S & F in repairs stainless steel soap dish made of stainless steel 1.00 mm thick, approximate size 100x75mm fixed to plugs with chromium plated brass screws complete all as specified and directed. |
| 61 | S & F in repair SS corner shelf (set of three) (size - 9'') fixed with and including chromium plated brass screws and wooden/plastic cleats complete all as specified and directed. |
| 62 | S & F Tumbler holder with toughened glass and SS bracket all as specified and as directed. |
| 63 | S & F in repair brass chromium plated fancy type Wall bath mixer with L-Bend for hot and cold all as specified and as directed. |
| 64 | Dismantling of cast iron or reinforced concrete drain pipe, jointed in cemented mortar and taking out of trenches or in vertical position of internal dia 100 mm & less including cowl, bends, T, Y etc. complete all as specified and directed. |
| 65 | S & F UPVC (SWR) gully traps of size 125/110 mm, setting and jointing with solvent cement complete all as specified and directed.Note:- UPVC (SWR) fittings shall be used as per recommendations of the manufacturer of the pipes. |
| 66 | S & F UPVC (SWR) pipes, Type 'B' 110 mm dia single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.Note:- Rate quoted shall include the cost of excavation & earthwork for the pipe laid in trenches and nothing extra shall be paid. |
| 67 | S & F UPVC (SWR) pipes, Type 'A', 110 mm dia single socketed, in any length with rubber ring joints fixed in walls with fixing factory made pipe supporting system with approved manufacturer instructions complete all as specified and directed. |
| 68 | S & F UPVC (SWR) pipes, Type 'B' 75 mm dia single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed. Note:- Rate quoted shall include the cost of excavation & earthwork for the pipe laid in trenches and nothing extra shall be paid. |
| 69 | S & F UPVC (SWR) pipes, Type 'B', 75 mm dia single socketed, in any length with rubber ring joints but fixed in walls with fixing factory made pipe supporting system with approved manufacturer instructions complete all as specified and directed. (Note for item no 66 & 68: Single pipe or multi pipe bracket system stack clamp (U bolt with noise absorbing transparent ribbed silicon ribber sleeve of 2mm thickness with set of knurling flange nuts +bracket +support) confirmed with outer dia of pipes fixed at intervals of every meter at a specified distance from the wall for vertical and horizontal lines, which are made of deep draw low carbon hot rolled gauge corrected (HRGC) steel (material grade:IS 1079DD), hot dip galvanising (IS 2629)+ZN-AL (Zink Aluminium flake) coated with ribbed support. All other details are as per TD No CEAG/AR/TD/08R. |
| 70 | S & F UPVC (SWR), junction single, (Single T) with door 110 mm dia equal or unequal complete all as specified and directed. |
| 71 | S & F UPVC (SWR), junction single, (Single T) with door 75 mm dia equal or unequal complete all as specified and directed. |
| 72 | S & F for UPVC (SWR) door bends 110 mm dia complete all as specified and directed. |
| 73 | S & F for UPVC (SWR) door bends 75 mm dia complete all as specified and directed. |
| 74 | S & F for UPVC (SWR) vent cowl 110 mm dia complete all as specified and directed. |
| 75 | S & F for UPVC (SWR) vent cowl 75 mm dia complete all as specified and directed |
| 76 | S & F UPVC (SWR) junction double, (double T), equal or unequal provided with access door 110 mm dia complete all as specified and directed. |
| 77 | S & F in repair for PVC (SWR), 75mm dia of floor trap, with grating including jointing with solvent cement complete all as specified and directed.Note for item no 69 to 76: UPVC (SWR) fittings shall be same make of pipe and as per recommendations of manufacturer of pipe. |
| 78 | Demolition of any old unserviceable roof treatment of any description including roof tiles/ padding etc.to expose the RCC Slab of roof, cleaning, washing & rubbing complete all as specified and directed. |
| 79 | M & L for applying brushing neat cement slurry with 3.0 kg of cement per sq. metre complete all as specified and directed. |
| 80 | M & L PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in roof padding (average thickness 50mm thick) complete all as specified and directed. |
| 81 | M & L 10 mm thick screed bed with CM 1:3 with liquid water proofing compound @ 3% by weight of cement surfaces finish even and smooth using without extra cement applied on padding concrete when concrete is stilll green complete all as specified and directed.Note: Water proofing compound shall be measured and paid seperately. |
| 82 | Supply only liquid water proofing compound ISI marked complete all as specified and directed. |
| 83 | M & L prepration of surface and providing Waterproofing membrane moisture cured, Polyurethane elastomeric liquid membrane waterproofing coating cold applied with brush/roller, with an elongation of >500% and tensile strength of 2 MPa as per ASTM D 412, 90 % Solid Content, shore A Hardness of min 50 as per ASTM D 2240. The system includes final base preparation as per note given below, PU primer application at 8 Sqm/L and applying PU chemical in two coats at 1.8 kg per Sqm providing 1.5 mm DFT, complete as per manufacturer specifications. Waterproofing membrane to be terminated on parapet wall in a V groove of size 25 mm x 25 mm atleast 300 mm above FFL which should be sealed with Polymer mortar complete all as specified and directed for work in building/structure of any height, completed as per manufacturer instruction.Note: Surface Preparation: (i) The surface to be treated should be sound and free from all types of dirt, dust and debris. Clean surface by brushing, scraping or chipping to eliminate all defective materials and foreign matter. Proper surface preparation needs dry mechanical grinding to expose base substrate. Making of angle fillets (75mmx75mm) all around the periphery of the wall with polymer modified mortar using SBR Latex. (ii) All construction joints and cracks > 1mm shall be treated by cutting V groove and filling with polymer modified SBR Latex and reinforced with geotextile membrane dipped in PU liquid Membrane before the 1st coat application. (For Non Accessible roofs) |
| 84 | Demoliton of un-reinforced cement concrete of any description for roofs, floor (Other than ground floor), beams, staicases, landing, chajjas and similar work and complete all as specified and directed. |
| 85 | M & L for water proofing treatment of sunken floor of WCs bathroom etc by applying of the following specification:-(i) Cleaning of sunken floor surface with mechanical means i.e wire brush/air blower etc and remove all loose/unsound material dirt dust etc. (ii) Applying cement slurry mixed with acrylic based polymer modified cementious composite compund coating in the ratio 1:2:4 (one part of acrylic polymer : two part of water and four part of cement) (iiii) First layer of cement slurry @ 0.444 kg/sqm mixed with acrylic based modified cementious composite compund @ 0.222 litre/sqm and allow it to air dry for 4 hour. (iv) Second layer of cement slurry @ 0.222 kg/sqm mixed with acrylic based modified cementious composite compound @ 0.111 litre/sqm and allow it to air dry for 4 hour followed with water curing for 48 hours (v) 200 micron thick polyethylene film shall be pasted with help of adhesive over treatment. (vi) Spout pipe to be refitted 20mm dia GI pipe of total length of 0.60 mtr. Note:- Joints of WC/Trap/Soil waste shall be properly sealed with sealing compund . Testing of all traps and joints and sunken slab shall be done as per IS-1742 before filling and tiling work complete all as specified and directed. |
| 86 | M & L for plain cement conrete 1:5:10 type E-2 (using 40 mm graded broken bricks aggregate ) as in foundation and mass concrete complete all as specified and directed. |
| 87 | M & L for joint free non skid ceramic tiles, coloured, 7 to 8 mm thick in floors etc. area of each tile exc. 0.06 sqm but n. exc. 0.11 sqm, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 88 | Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc. 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 89 | M & L for 25 mm thick PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate in sub floors mixed with liquid water proofing compound ISI marked complete all as specified and directed.Note : Water proofing compound shall be measured and paid seperately. |
| 90 | M & L for joint free light shade non skid ceramic tiles, coloured, 9 to 10 mm thick in floors (square/rectangular) area of each tile exc. 0.18 sqm but n. exc. 0.38 sqm, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 91 | M & L for glazed ceramic wall tiles, coloured, 450 x300 x 7-8mm thick on vertical surfaces such as skirtings, dados and risers to steps etc, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:3 on stone or brick masonry surfaces complete all as specified and directed. |
| 92 | M & L for matching with floor tiles 9 to 10 mm thick on vertical surfaces such as skirtings, dados and risers to steps etc, area of each tile exc. 0.18 sqm but n. exc. 0.38 sqm set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:3 on stone or brick masonry surfaces complete all as specified and directed. |
| 93 | Dismantling of stone slabs and tiles of any description or thickness in floors, aprons laid in grey cement any type of mortar etc. complete all as specified and directed. |
| 94 | M & L for machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and including 20 mm screed bed or bedding layer in cement mortar 1:4 complete all as specified and directed. |
| 95 | M & L for pre-polished kota stone slab 20-25 mm thick in riser/tread (one piece slab for each tread/risers) including grooving (two lines) and bull-nose edge, set & jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering in CM 1:4 on stone masonry surfaces complete all as specified and directed. |
| 96 | M & L Granite (of any type) stone 18mm to 20mm thick machine cut one stone, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing with bull-nose, over 20 mm thick screed bed or bedding layer for laying floor finishes in CM 1:6 complete all as specified and directed. |
| 97 | M & L Granite (of any type) 18mm to 20mm thick tiles machine cut, in vertical/skirting/dado laid over cement mortar 1:3 and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed. |
| 98 | M & L Green marble work 18 to 20mm thick (table rubbed and polished) in one piece of stone as in steps, jambs, pillars, window cills, cooking platforms and like jointed in cement mortar (1:4), including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of marble over 15 mm thick Screed bed or bedding layer for laying floor finishes in CM 1:4 complete all as specified and directed. |
| 99 | Demolition of reinforced cement concrete of any description for roofs, floor (Other than ground floor), beams, staircases, landing, chajjas and similar work complete all as specified and directed. |
| 100 | M & L for RCC 1:1.5:3, Type A1 (20mm graded aggregate) for chajja, roofs, landings, balconies, deck slab and in shelves and the like and chajja at any height complete all as specified and directed. |
| 101 | M & L for mild steel TMT bars 10mm dia and over, cut to length, bent shape required, including cranking, bending, hooking etc and binding with MS wire 0.9mm dia (annealed) complete all as specified and directed. |
| 102 | M & L for Formwork to soffits of suspended slabs for rough finished flat surfaces of concrete such as roof slabs, floor slabs, landing and similar work: not exc 200 mm thick (horizontal or sloping) complete all as specified and directed. |
| 103 | M & L for Formwork to edges of concrete flats, treads, breaks in floors, concrete railings, opening in concrete walls, floor and roofs n.exc 20 cm wide and sides of RCC / PCC bands in walls, horizontal or sloping and similar work exc 10 cm but n.exc 20 cm wide for rough finished complete all as specified and directed. |
| 104 | S & F for Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber / neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all as per TD drawings complete all as specified and directed. |
| 105 | S & F powder coated aluminium sliding window three track with outer frame & two glass shutter and one shutter with stainless steel wire gauge wire cloth using aluminium powder coated section aluminium cleat, PVC track, bearing, handle lock rubber beading etc complete fittings as approved. Note :- Size of aluminium section shall be as under – (i) Three track top and vertical – jindal main 2010 Section No 20621 or equivalent as approved by GE.(ii) Three track bottom – Jindal main – 2010 section 20620 or equivalent as approved by GE.(iii) Shutter Vertical Section - Jindal main – 2010 section 20604 or equivalent as approved by GE.(iv) Shutter top and bottom - Jindal main – 2010 section 20604 or equivalent as approved by GE.(v) Shutter vertical middle (interlock) - Jindal main – 2010 section 20605 or equivalent as approved by GE. Note : Wiremesh and Glass measured and paid separately. |
| 106 | S & F Powder coated Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.), hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed. |
| 107 | S & F anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening complete all as specified and directed. |
| 108 | S & F 4.00mm thick float glass (tinted), selected quality and glazing with suitable arrangements to aluminium window / ventilator shutters in square n.exc 0.5 sqm in each pane complete all as specified and directed. |
| 109 | S & F 4.00mm thick Sheet glass, selected quality and glazing with suitable arrangements to aluminium window / ventilator shutters in square n exc 0.5 sqm in each pane frosted on one side complete all as specified and directed. |
| 110 | S & F in repairs stainless steel curtain rod of grade-304, 1mm thick in any length, stainless steel pipe having outer dia minimum 25 mm complete all as specified and directed. |
| 111 | S & F in repairs brackets with decorative finials stainless steel matching colour of same colour of 25 mm dia rod or as directed complete all as specified and directed. |
| 112 | M & L for providing and injecting chemical emulsion for post construction anti termite treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 ltr per sqm of the vertical surface of the sub structure to a depth of 300 mm including excavating channel along the wall and rodding etc complete all as specified and directed. |
| 113 | M & L removing building materials etc. (other than spoil payable under respective items) to a distance of 3.00 KM (outer side MD land) beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and directed.Note: No extra lead shall be paid beyond 3.0 KM, all debris shall be reomved. |
| 114 | M & L for cutting shrubs, wild growth / Vegetations and removal of plant growth by grubbing out shrubs / plants / any vegetation growth n.exe 10cm girth including cutting of trunk portion protruding outside the walls / roof, digging out roots and application of chemical Glyphosate solution (4% concentration) as per manufacturer's instructions by injecting in stem of plants and roots as directed and removing complete vegetation growth from walls including taking out roots from roof / stone / block masonry work and making good the disturbed surface with PCC 1:2:4 type B-0 and disposing off the rubbish from the site outside MoD land, for upto four story buildings (incl scaffolding) complete all as specified and directed. |
| 115 | M & L 75mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in plinth protection finished surface even and fair without using extra cement complete all as specified and directed. |
| 116 | M & L for forming contraction (dummy) joints 65mm deep x 10mm wide, filled with sealing compound Grade 'A' complete all as specified and directed. |
| 117 | S & F 35 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides & both face is covered with decorative face veneer with lipping / frame to match as per manufacturing instructions complete as specified by the manufacturer and as per directions. |
| 118 | M & L galvanised mild steel plain wire 3.15mm dia for drying cloth complete all as specified and directed. |
| 119 | M & L 5.5mm thick, 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick PVC sheet and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 120 | S & F pillar cock with aerator (for table top WHB), cast copper alloy, fancy type with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold with long screwed shanks and fly-nuts, 15mm bore complete all as specified and directed. |
| 121 | Demolition of brick work or stone masonry built in cement mortar complete all as specified and directed. |
| 122 | M & L for pre-cast cement concrete block masonry type C1, 1:3:6 (using 20mm graded stone aggregate) with solid blocks, exceeding 10 cm in width and setting in CM 1:6, complete all as specified and directed. |
| 123 | M & L for providing precast reinforced cement concrete Type A1 (1:1.5:3) Nominal mix (using 20mm graded crushed stone aggregates) as in cover slab or similar works set & jointed in CM 1:4 complete all as specified and directed. Note :- Reinforcement shall be measured & paid separately under respective item. |
| 124 | S & F 6mm to 8mm dia TMT bars, as in reinforcement, cut to length, bent to shape required including cranking binding with mild steel wire (annealed) not less 0.9 mm dia complete all as specified and directed. |
| 125 | M & L PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) in copings, haunching, kneelers, apex stones, bed plates and manhole kerbs and like rounded or chamfered where required including necessary form work complete all as specified and directed. |
| 126 | M & L demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed. |
| 127 | M & L PCC type C2 (1:3:6) using 40 mm graded stone aggregate as in foundations, filling and mass-concrete complete all as specified and directed. |
| 128 | M & L PCC (1:2:4) type B1 using 20 mm graded stone aggregate as in surface channels and drains complete all as specified and directed. |
| 129 | Extra for forming fair finish drain or channel 30 cm inner girth using extra cement including necessary forms mould mitered / stopped ends etc. complete all as specified and directed. |
| 130 | M & L rendering 10 mm thick on block masonry surfaces or surface other than fair faces of brickwork in CM (1:4) mixed with water proofing compound 3% by weight of cement finished even & smooth without using extra cement complete all as specified and directed. Note : WPC shall be measured & paid separately. |
| 131 | M & L for rendering 15 mm thick in CM 1:4 on fair faces of brick work / concrete surfaces finished even and smooth complete all as specified and directed. |
| 132 | Supply only integral water proofing compound ISI marked complete all as specified and directed. |
| 133 | M & L for MS work as in clamps, steps, supports, hold fast, wall ties, rungs, handles of manholes and other similar articles complete all as specified and directed. |
| 134 | M & L for surface dressing not exceeding 15 cm deep in soft / loose soils complete all as specified and directed. |
| 135 | M & L 100 mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate in sub base of floor complete all as specified and directed. |
| 136 | M & L for providing and laying 60 mm thick factory made chamefered edge cement concrete paver block of M-35 grade with approved colour design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc of required strength thickness & size shape made by table vibratory method using PU mould laid in required colour & pattern over and including 50 mm thick compacted bed of fine sand comapcting and proper embedding / laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator filling the joints with sand and cutting of paver blocks as per required size and pattern finishing and sweeping extra sand complete all as specified and directed. |
| 137 | M & L for providing and laying at or near ground level, factory made kerb stone of M-25 grade cement concrete placed in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement : 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed. |
| 138 | E/M Works |
| 139 | Taking down copper / aluminium point wiring (light, fan, bell, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendent, regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition seperately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed. |
| 140 | Taking down old / unserviceable distribution board by disconnection of electric connection carefully SPN DBs / TPN DBs / Main Switch including old unserviceable MCCBs / MCBs, Isolators etc and making good to disturbed surface complete all as specified and directed. |
| 141 | Taking down carefully copper / aluminium sub main wiring of any size from surface / concealed / existing conduit at any height and removing materials at site and making good disturbed surfaces of walls, floors, roofs etc complete all as specified and directed. |
| 142 | Taking down ceiling fan / exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades and deposit to MES store yard of AGE E/M (AF) Jodhpur No.2 for reuse of serviceable fan complete all as specified and directed. |
| 143 | Taking down existing electrical storage geyser of any capacity after disconnecting all necessary electrical and water supply connections and deposit to MES store yard of AGE E/M (AF) Jodhpur No 2 for reuse of serviceable geyser complete all as specified and directed. Please Enable Macros to View BoQ information |
| 144 | Taking down existing electrical storage geyser of any capacity after disconnecting all necessary electrical and water supply connections and deposit to MES store yard of AGE E/M (AF) Jodhpur No 2 for reuse of serviceable geyser complete all as specified and directed. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail