| 1 | Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. |
| 2 | All kinds of soil |
| 3 | Ordinary Rock |
| 4 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 min width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides andramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth asdirected:25 meter beyond 1 m from cutting edge All kinds of soil |
| 5 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 min width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides andramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth asdirected:25 meter beyond 1 m from cutting edge Ordinary Rock |
| 6 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 min width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides andramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth asdirected:All kinds of soil : |
| 7 | Dumping stone including cost of stones. in Horizontal on level |
| 8 | Dumping stone excluding cost of stones. in Horizontal on level |
| 9 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 10 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete. |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for:Columns, pillars, piers, abutments, posts and struts. |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for:Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 14 | Centering and shuttering including strutting, propping etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platforms. |
| 15 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 16 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 17 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 18 | Construction of ornamental RCC slab place given wooden look in columns,beams,evas boarding, railing,flooring,slab including reinforcement as per site requirement including centring and shuttering complete job (Reinforcement to be used 12mm doa.) including all leads and lifts |
| 19 | Excavating, supplying and filling of local earth (including royalty)by mechanical transport upto a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 20 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m. |
| 21 | Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunk and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material. Beyond 30 cm girth upto and including 60 cm girth. |
| 22 | Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunk and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material. Beyond 60 cm girth upto and including 120 cm girth. |
| 23 | Random Rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 Cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level and curing complete with: Cement mortar 1:6 (1 Cement : 6 coarse sand) |
| 24 | Dry random rubble masonry with hard stone in foundation and plinth:Without bond stone |
| 25 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 26 | Providing and laying in position Crash Barrier including fixing in cement concrete of specified grade including curing 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) and all necessary fixers etc. |
| 27 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) |
| 28 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate. |
| 29 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 30 | Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level |
| 31 | Filling of Brick Bat in soakage pit in layers including cost of brick bat and carriage all complete |
| 32 | 12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 fine sand) |
| 33 | 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 6 ( 1 cement : 6 fine sand) |
| 34 | 20mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand) |
| 35 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately):Second class deodar wood |
| 36 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately).Second kail wood |
| 37 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40mm thick. Second Class kail wood |
| 38 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.Float glass panes 1 4 mm thick glass pane (weighing not less than 10 kg/sqm) |
| 39 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge :Second class Kail wood |
| 40 | Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete. |
| 41 | Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road / vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening /binding material to fill up interstices of coarse aggregate, watering and compacting to the required density. |
| 42 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm |
| 43 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement and matching pigments etc. complete. Size of tile 600x600 mm |
| 44 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. In all colours, shades, except White, Ivory, Fume Red Brown |
| 45 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shadesexcept burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 46 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and asdirected by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 47 | Kota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing, polishing and curing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) : |
| 48 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1 mm thick |
| 49 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer |
| 50 | Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm) |
| 51 | Applying priming coat:With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 52 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on new work |
| 53 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.Welded |
| 54 | Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 55 | Providing and fixing plained eaves boarding. 2nd class Deodar wood 250x32 mm (nominal size) |
| 56 | Providing and fixing precoated galvanised steel sheet roofingaccessories0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm |
| 57 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. |
| 58 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slabwith suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 59 | Providing and fixing ISI marked oxidized M.S. sliding door bolts with nuts and screws etc. complete :300x16 mm |
| 60 | Providing and fixing ISI marked oxidized M.S. tower bolt black finish, (Barrel type) with necessary screws etc complete.250x10 mm |
| 61 | Providing and fixing ISI marked oxidized M.S. tower bolt black finish, (Barrel type) with necessary screws etc complete.150x10 mm |
| 62 | Providing and fixing ISI marked oxidized M.S. handles conforming to IS : 4992 with necessary screws etc. complete : 125 mm |
| 63 | Providing and fixing ISI marked oxidized M.S. handles conforming to IS : 4992 with necessary screws etc. complete :100 mm |
| 64 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 65 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 453x357 mm |
| 66 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete: 40 mm dia |
| 67 | Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift upto1.5 m in -All kinds of soil. |
| 68 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colou r& pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratorycompaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as per direction of Engineer-in-Charge. 1 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. |
| 69 | Providing Solar LED Street Lighting System Load Capacity 30W,Weight 15.5kgs,Battery Capacity 14.8/16AH,IP Rating IP66,IP65,Solar Module 60W/18V Monocrystalline with 5 years Warranty, Pole Height 6M.(Complete Job) |
| 70 | Providing and fixing white vitreous china pedestal type water closet(European type W.C. pan) with seat and lid, 10 liter low level whiteP.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid. |
| 71 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe (of approved make) with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required.White vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests. |
| 72 | Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan. |
| 73 | Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. |
| 74 | Providing and fixing 600x120x5mm glass shelf with edges round off supported on anodized aluminum angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs, etc.complete |
| 75 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete:Flexible pipe 40 mm dia |
| 76 | Providing and fixing of 15 mm CP bib cock of approved make ( Jaquar make) having code no. CON CHR 037 confirming to IS 2980 |
| 77 | Providing and fixing of CP Angle value of Jaquar make having code no. CON CHR053 |
| 78 | Providing and fixing of CP mixer of approved make having code no. 167 B |
| 79 | Providing and fixing of 600 mm long tower rail of approved make having code no. 1111 |
| 80 | Providing and fixing of scuare tower ring having code no. 1121 |
| 81 | Providing and fixing of CP soap dish of approved make having code no. 1131 N |
| 82 | Providing and fixing of CP paper holder of approved made with necessar screw and plastic gatti make having code no. 1151 |
| 83 | Providing and fix of CP shower of approved make having code no. 1799 incl. shower arm |
| 84 | Providing and fixing 10mm sand CP grating for gully, floor or nahani trap. |
| 85 | Providing and fixing of CP neeple of approved make |
| 86 | 100mm inlet and 100mm outlet sand cast iron S&S as per IS: 1729 |
| 87 | 100mm inlet and 75mm outlet sand cast iron S&S as per IS: 1729 |
| 88 | Providing installation and testing of Geyser of approved quality and manufacture jagwar make mounted on boltd, well anchored in wall and connected with hot and cold G.I. connection with superior angle values as required: (25 litres capacity) |
| 89 | Providing and fixing G.I pipes complete with G.I fittings and clamps, including cutting and making good walls.25 mm dia nominal bore (medium) |
| 90 | Providing and fixing G.I pipes complete with G.I fittings and clamps, including cutting and making good walls.15mm dia nominal bore (medium) |
| 91 | Providing and fixing G.I pipes complete with G.I fittings and clamps, including cutting and making good walls.20mm dia nominal bore (medium) |
| 92 | Concealed pipe including painting with anti-corrosive bitumastic paint, cutting chases and making good the wall 15mm dia nominal bore |
| 93 | Concealed pipe including painting with anti-corrosive bitumastic paint, cutting chases and making good the wall 20mm dia nominal bore |
| 94 | Providing and fixing G.I pipes complete with G.I fittings and clamps, excluding trenching and refilling etc. (external work)(25mm dia nominal bore.) |
| 95 | Making connection of G.I distributing branch with G.I main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete.and making long screws etc. complete. (25 to 40mm nominal bore) |
| 96 | Fixing water meter and stop cock G.Ipipe line including cutting and threading the pipe and making long screws etc. complete. (cost of water meter and stop cock to be paid separately) (20 mm to 25 mm) |
| 97 | Providing and fixing ball value (brass) of approved quality complete. High or low pressure with plastic floats.20 mm nominal bore |
| 98 | Providing and fixing ball value (brass) of approved quality complete. High or low pressure with plastic floats.15 mm nominal bore |
| 99 | Providing and fixing of PVC pipe of 4Kg/ Cm Square of approved make ( Spureme) for carring disposal of seat and waste water of wash basin etc. incl. scalfoliding complete.100 mm |
| 100 | Providing and fixing of PVC pipe of 4Kg/ Cm Square of approved make ( Spureme) for carring disposal of seat and waste water of wash basin etc. incl. scalfoliding complete.75 mm |
| 101 | Providing and fixing PVC floor trape of supreme make of size 100x 75 |
| 102 | Providing and fixing of PVC collar of approved make of supreme make 100 mm |
| 103 | Providing and fixing of PVC collar of approved make of supreme make 75 mm |
| 104 | Providing and fixing of PVC plain bend of supreme make 100 mm |
| 105 | Providing and fixing of PVC plain bend of supreme make 75 mm |
| 106 | Providing and fixing of steel clamp of good quality incl. fixing the screws and making good the wall 100 mm |
| 107 | Providing and fixing of steel clamp of good quality incl. fixing the screws and making good the wall 75 mm |
| 108 | Providing and fixing of PVC Door bend of supreme make 100 mm |
| 109 | Providing and fixing of PVC Door bend of supreme make 75 mm |
| 110 | Providing and fixing of PVC door Tee 100 mm |
| 111 | Providing and fixing of PVC door Tee 75 mm |
| 112 | Providing and filling of joints in PVC pipe with solution and ring of required size 100 mm |
| 113 | Providing and filling of joints in PVC pipe with solution and ring of required size 75 mm |
| 114 | Making hole up to 20x20 cm and embedding pipes up to 150mm diameter in masonry and filling with cement concrete 1:3:6 (1 cement: 3 coarse sand 6 graded stone aggregate 20mm nominal size) including disposal of malba. |
| 115 | Constructing brick masonry chamber for underground C.I. inspection chamber and bend with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg ) R.C.C. top slab with 1:1 ½ : 3 mix ( 1 cement : 1 ½ coarse sand : 3 graded stone aggregate 20 mm nominal size),foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design Inside dimensions 455x610 mm and 45 cm deep for singlepipe line- |
| 116 | Supplying and fixing C.I. cover without frame for manholes: 455x610mm rectangular C.I. cover (light duty) the weight of thecover to be not less than 23 kg. |
| 117 | Carriage of material by Mechanical Transport including loading / unloading and stacking at site complete. |
| 118 | Bricks for an average distance of 280 km by MT and 700 mtr by HL |
| 119 | Stone for an average distance of 1 km by HL |
| 120 | Sand for an average distance of 40 km by MT and 700 mtr by HL |
| 121 | Stone aggregate below 40 mm nominal size for an average distance of 40 km by MT and 700 mtr by HL |
| 122 | Steel & C.G.I. Sheets for an avg. distance of 40.00km by MT & 700m by H/L |
| 123 | Earth/Mulba for an avg. distance of 5km by MT |
| 124 | Cement for an avg. distance of 40.00km by MT & 700m by H/L Please Enable Macros to View BoQ information |