| 1 | Demolishing R.C.C. work including stacking of steel bars & disposal of unserviceable within 50 mts. lead. |
| 2 | Demolishing cement concrete 1:3:6 or richer mix including disposal of material within 50 m lead. |
| 3 | Demolishing laterite stone masonry in cement mortar including stacking of serviceable material & disposal of unserviceable material within 50 mts. lead. |
| 4 | Dismantling asbestos sheet roofing including ridges, hips valley and gutters and stacking the material within 50 meters lead. |
| 5 | Dismantling steelwork in built up sections in angles, tees, flats and channels including all gusset plates bolts, nuts, cutting dismembering and staking within 50 mts. Lead |
| 6 | Dismantling the tile work in floors and roofs laid in cement including stacking of materials within 50 meters lead for thickness of tiles 10mm to 25mm. |
| 7 | Taking out doors, windows and clerestory windows shutters (steel or wood) including stacking within 50 mts. Leada) Of area 3 sq.m. and below |
| 8 | Earthwork in surface excavation not exceeding 30 cm depth(but exceeding 1.5 m width as well as 10 sq.m on plan) including disposal of excavated earth beyond work site for all leads lift disposed earth to be leveled and neatly dressed in:a) Ordinary soil |
| 9 | TRANSPORTATION AND CARRIAGE OF MATERIALS(A) By tipper truck including loading, unloading and stacking(i) Sand stone metal below 40 mm |
| 10 | CARRIAGE OF MATERIALS(B)By mechanical transport including loading, unloading and stacking(i) Sand stone metal below 40 mm |
| 11 | Laterite masonry in neatly dressed stones for 23 cms thick masonry walls in c.m. 1 : 4 (1 cement : 4 coarse sand in foundation upto plinth levelExtra for laterite masonry in all sizes in superstructure from floor I level upto floor V level. |
| 12 | Brick work using common burnt building bricks in cement mortar 1:4 (1 cement : 4 coarse sand) with bricks of class designation 40 kg / cm2.b) In superstructure upto floor five level. |
| 13 | Centering & shuttering including Strutting, Propping & removal of forms forv) Sides and Soffits of beams, Beam Haunchings, Cantilever, Girders, Bressumers and Lintels plinth beams exceeding 1m in depth |
| 14 | RCC work 1:2:4 (1 cement: 2 coarse sand: 4 granitic or basaltic stone aggreate 20mm nominal size in chajjas exceding 15cms thickness upto 1st level including finishing and plastering the exposed surface with cement mortar 1:3 (1 cement: 3 fine sand) of thickness not exceeding 6mm to give an even surface throating & moulding, centering, shuttering but excluding cost of reinforcement |
| 15 | Earthwork in excavation by mechanical means (hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sq.m on plan) including disposal of excavated earth lead upto 50 m and lift upto 1.5m disposed earth to be leveled and neatly dressed including providing barricading, danger lighting guarding as directed in :a) All kinds of soil |
| 16 | Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete. |
| 17 | Centering and shuttering including struttings, propping etc. and removal of formwork for a) Foundations, footings, bases for columns and mass concrete. |
| 18 | Providing & laying cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stone aggregate. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in: |
| 19 | Providing Pre-cast cement concrete jali 1:2:4 (1 cement: 2 coarse sand: 4 stone aggreate 6mm nominal size) reinforced with 1.6mm dia mild steel wire including centering and shuttering, roughening, cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine snad) all complete excluding plastering of the jambs, sills and soffitsiii)25mm Thick |
| 20 | Providing and laying integral cement based treatment (Box type) for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer and consisting of : i) Ist layer of 20 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions. iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm / sqm thoroughly embedded in the 2nd layer using rough Shahbad / Kotah stone. |
| 21 | Providing and laying integral cement based treatment (Box type) for water proofing on the vertical surface by fixing specified stone slab 20 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer using rough Shahbad/Kotah stone. |
| 22 | Wood Finish Foam Core FRP (Fiber Reinforced Polymer) Door Shutter Manufacture, Supply and Installation (including accessories as mentioned below) of EPEE or equivalent Goan make FRP (Fiber Reinforced Polymer) door shutter of specified thickness as per options below by using tray system, with seasoned hard wood, moisture less than 17%, wood styles for Top rail and lock rails. FRP (Fiber Reinforced Polymer) laminate made up of 450 grams per sq.mts (gsm) chop strand matt and unsaturated polyester resin with viscosity range of 400/450 centipoises per second (cps) along with printed matt having wooden textures, used along with UV Resistant resin to give the clear wooden texture on the door. The core of shutter will be filled as specified (Expanded Polystyrene Foam / Polyurethane Foam (EPS / PU) Foam) The shutter to be water proof as well as mild acid / alkali resistant manufactured using RV TIFAC (R V Engineering College, Bangalore & Technology Information Forecasting & Assessment Council) Technology in line with IS 13034 1990 test Standard in an ISO 9001 – 2015 certified factory.i) S. S. Hinges 4” - 3 NoiiS. S. Latch - 1 Noiii) Tower Bolt 5” - 2 Nosiv) Handle 5” - 2 NosShutter Thickness b) 35mm |
| 23 | Providing & fixing Two Track sliding window in economical section made out of 60mm x 45mm x 2.5mm Upvc multi cavity track section & Shutter made out of 57mm x 31mm x 2.5mm Upvc multi cavity section welded in corners with Glass beading & EPDM Gasket & 4mm clear glass with lock & rollers. The average weight of Two Track Sliding window (Economical) is 12.25 kg per sq mtr. These Upvc sections are tested by using BS 2782 & DIN 53459 test methods. |
| 24 | Supply and installation of Aluminium Louvers. The frame should be made of Aluminium tubes of size 100x50X1.50 mm thk and 50X25x1.50 mm thk C channels. Aluminium Z shaped louvers of 100mm should be fixed to the supporting frame with aluminium cleats, GI screws, etc complete. The whole assembly is powder coated with pure polyester paint. (MS framing to be paid separately) |
| 25 | Waterproofing of sunken slabs, toilet blocks, terraces on slabs under brickbats, roofs, watertanks. Cleaning the surface and filling cracks (if any), applying EPCO ACR wherever necessary, Providing and Moistening the surface with water to render it saturated. Mix Cement and Monobond WF in the ratio of 1.25 kg to 1 by weight and stir continuously. Apply minimum 2 coats with an interval of 12 hours minimum between the coats. Fix fiber mesh while the first coat is still tacky. Cure with sprinkling of water 3-4 times a day. incl. cost of scaffolding transport etc. as per dir of EIC. All the chemicals will be of Krishna Conchem Products Pvt. Ltd. or Equivalent |
| 26 | 12mm cement plaster 1:4 (1 cement : 4 fine sand) |
| 27 | Removing old paint of polish with paint remover of approved brand & manufacture & preparing surface |
| 28 | Providing and applying white cement based putty of average thickness 1.00mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 29 | Applying one coat of distemper primer of approved brand and manufacture on wall surface. |
| 30 | Wall painting (two or more coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade. |
| 31 | Painting one or more coats of acryllic exterior paint of approved brand and manufacture (Such as Dulex / Asian Paints / Sherwin Willians) on old work including cleaning the surface with water etc. complete. |
| 32 | Providing and fixing 40 mm dia G.I. Pipe railing in 3 rows complete with G.I. Fittings incl. Painting of pipes and fittings with white paint of approved quality incl. A priming coat with a ready mixed primer for new works incl. Providing R.C.C. 1:2:4 rail posts of size 0.15 x 0.15 x 1.00 M with base of 0.25 x 0.25 x 0.3 m at every 2 mts intervals and double rail post with a bar drawings inclusive of cost of reinforcement etc. all complete including white wash washing of rail posts etc. all complete. |
| 33 | Providing and and laying vitrified floor tiles in different sizes of Johnson, Somany, Kajaria (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make in colours and shades as specified laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including grouting the joints with white cement and matching pigment etc., completec) 900 x 900 mm - Dark Shades |
| 34 | Providing and fixing vitrified antiskid tiles (320 x 320) and 10mm thick tiles in floor, treads of steps, landing on 25mm thick bed of cement mortar 1:3 and jointed with cement slurry complete. |
| 35 | White glazed tiles 6 mm thick in skirting, risers of steps & dado on 12 mm thick cement plaster 1:3 (1 cement : 3 coarse sand and jointed with white cement slurry. |
| 36 | Providing and fixing coloured ceramic tiles spartek or equivalent of 12 \\" x 12\\" (399x150 mm cut size) 6 mm thick in skirting and dados on 12 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) and jointed with cement slurry complete. |
| 37 | Floor mounted WC 350 X 480 X 390 - Jaquar makeb) CNS-WHT-553SS |
| 38 | Wall Hung Basin - Size 575 X 475 X 195 - Jaquar make (OPS-WHT-15801) |
| 39 | Providing and fixing 10 litres pvc. Automatic flushing cistern with fittings. |
| 40 | Providing and fixing Hand Shower (Health Faucet) with 8mm dia, ABS / brass body with double lock 1.00m long Flexible tube (Brass plated stainles steel flexible hose) and wall hook of approved quality confirming to IS standards. |
| 41 | Providing and fixing NICKEL chrome plated copper alloy Fancy Two Way Bib Cock with single knob and wall flange conforming to IS 8931:1993 15mm nominal bore. |
| 42 | Providing and fixing NICKEL chrome plated copper alloy Fancy Pillar Cock rocket type Jaquar make or equivalent. Confirming to IS 8931;199315mm nominal bore |
| 43 | Providing and fixing NICKEL chrome plated copper alloy Fancy BIB Cock Short Body Jaquar make or equivalent. Confirming to IS 8931;199315mm nominal bore |
| 44 | Providing and fixing 600 x 450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleats with C. P. brass screws and washers. |
| 45 | Providing and fixing C. P. brass waste for wash basins and sinka) 32 mm dia |
| 46 | Providing and fixing NICKEL chrome plated copper alloy Fancy BOTTLE TRAP ECONOMY TYPE 32MM Jaquar make or equivalent Confirming to IS 8931;1993 |
| 47 | Providing and fixing nahani trap of rigid PVC (approved make) for S.W.R. pipes including lubricating etc complete, without door :(b) 75 mm dia |
| 48 | Providing and placing on terrace roof of floor two (1st flor roof single piece rotational moulded polythene water storage tank having I S I mark and conforming to I S 12701; 1996.Extra for placing polythene tank on roof of floor three (2nd floor roof)C) 1000 lit. capacity |
| 49 | Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Concealed work (medium duty SDR 13.5 pipe) including cutting chases and making good the walls etc.20 mm dia nominal outer dia pipes. |
| 50 | Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes confirming to IS: 15778 having thermal stability for hot and cold water supply includng all CPVC plain and brass threaded fittings CPVC solvent cement, trenching, refilling and testing of joints complete as per firectionof the Engineer in charge. (External work (heavy duty SDR 11 pipe)b) 20 mm dia nominal outer dia pipes. |
| 51 | Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes confirming to IS: 15778 having thermal stability for hot and cold water supply includng all CPVC plain and brass threaded fittings CPVC solvent cement, trenching, refilling and testing of joints complete as per firectionof the Engineer in charge. (External work (heavy duty SDR 11 pipe)f) 50 mm nominal outer dia pipes. |
| 52 | Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step UPVC solvent cement and testing of joints complete as per direction of Engineer. Internal work - Exposed on wall.I) SCH-80(blue)/(white)a) 20 mm outer dia . |
| 53 | Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including jointing of pipes & fittings with one step UPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer. External work.I) SCH-80(blue) / (white)a) 20 mm dia nominal outer dia pipes. |
| 54 | Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including jointing of pipes & fittings with one step UPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer. External work.I) SCH-80(blue) / (white)c) 32mm outer dia. |
| 55 | Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including jointing of pipes & fittings with one step UPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer. External work.I) SCH-80(blue) / (white)e) 50 mm nominal outer dia pipes. |
| 56 | Gypliner or equivalent ceiling which includes providing & fixing G.I. HG angle of sie 0.55 mm thick having two equal flanges of 25 mm each screw fixed to brick wall / partition with the help of nylon sleeves & screws at 610 mm c/c. Then suspending chan 12.5 mm tapered edge Gypboard (confirming to IS:2095-1982) is then fixed to channel section with 25 mm drywall screws at 230 mm centre. Screw fixing is done mechanically with drill machine and suitable attachment. Finally square and tapered edges joints of the boards are jointed and finished so as to have flush look which includes filling finishing with jointing compound, joint paper tape and two coats of Drywall top coat suitable for Gypboard (as per recomended practices of India Gypsum Limited). |
| 57 | Providing and laying factory made Shot blasted cement concrete interlocking paver block of minimum M35/M40 grade made by heavy duty block making machine with strong vibratory compaction and of aprpoved size and design / shape laid in 50 mm thick compacted bed of coarse sand, filling the joints with coarse sand, etc. all complete as per the direction of Engineer.- in I, Wave, Rectangular, Square etc. shapes. The products should comply to IS 15658:2006 and manfucatured by ISO9001: 2008 certified plant. The shot blasting should be done using 0.4-0.5mm dia steel shots with a speed of 3200 rpm.C) 80 mm thick in all colours except grey (M40 grade) |
| 58 | Providing & applying Rustonil (P.No.569) or equivalent for removing rust & phospating of steel structures or steel reinforcement in RCC to be applied in 1 coat it necessary then 2nd coat) before application of bonding agent. |
| 59 | Supplying and stacking of good earth at site including royalty and carriage upto 1 km. (earth measured in stacks will be reduced by 20% for payment). |
| 60 | Rough dressing the trenched ground including breaking clods. |
| 61 | Spreading of sludge, dung manure or/and good earth in required thickness (cost of sludge, dung manure or/and good earth to be paid separately). |
| 62 | 1) Grassing with “doob” grass including watering and maintenance of the lawn for 30 days or more till the grass forms of thick lawn free from weeds and fit for moving, including supplying good earth if needed. (Cost of “doob” grass not included )c)3) In rows 5 cm apart in either direction |
| 63 | Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in ratio of 2: 1 by volume (2 parts or stacked volume of earth after reduction by 20% and 1 part of stacked volume of manure after reduction by 40%) flooding with water, dressing including removal of rubbish & surplus earth if any with all leads & lifts (cost of manure or sludge of extra good earth if needed to be paid for separately)Holes 1.2m dia and 1.2m deep |
| 64 | Providing and fixing M.S. flat iron tree guard 60cm dia & 2 m high above ground level, formed of 4 nos. 25 x 6mm and 8 nos. 25 x 3mm vertical M.S. flat iron rings in two halves, bolted together with 8mm dia and 30 mm long bolts including painting two coats with paint of approved brand and manufacture over a coat of priming, complete in all respects. |
| 65 | Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in PVC casing caping with modular switch, modular plates, suitable size modular surface box of specified Category and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc. as required.(c) Group C -- with Cat A Modular Accessories |
| 66 | CFL ESSENTIAL 23W , 3U, COOL/WARM |
| 67 | Supply of 4 feet 36/40 W single decorative type fluorescent luminaire with electronic ballst complete with all accessories including 4 feet 36/40 W fluorecent tube.(a) Cat A |
| 68 | Supply and erecting of 48 inch (1200mm sweep) ceiling fan, double ball bearing type, complete with all accessories.a) Cat A |
| 69 | Installation, earthing, testing and commissioning of ceiling fan including wiring the down rod of standard length (upto 30 cm) with 1.5 sq .mm FR PVC insulated copper conductor single core cable including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 70 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required(a) Cat A |
| 71 | Fan Hook Box type |
| 72 | Supplying and fixing extra down rod of 20 cm length GI pipe 15 cm dia heavy gauge including painting etc as required |
| 73 | Supply and erecting S type Mild Steel fan hook fabricated out of 12 mm round bar complete as required. |
| 74 | Supply and erecting 'J' type Mild Steel fan hook fabricated out of 35 X 6 mm flat strip suitable for rafters complete with coach screws etc as required.(c) For 8 inches rafter size |
| 75 | Wiring for circuit / submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor single core cable in the independent PVC casing capping of appropriate size as required.2 x 1.5 Sq.m + 1 x 1.5 Sq.m (Ground Wire) |
| 76 | Wiring for circuit / submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor single core cable in the independent PVC casing capping of appropriate size as required.(c) 2 x 4 sq.mm + 1 x 4 sq.mm earthwire (20mm casing ) |
| 77 | 25 mm dia ISI marked Rigid PVC conduit (Heavy) conforming to IS 9537 |
| 78 | Supplying and fixing following size modular GI box alongwith modular base and cover plate for modulator switches in recess etc. as required(e) 12 Module (200 mm x 150 mm) Cat A |
| 79 | Supplying and fixing following size modular GI box alongwith modular base and cover plate for modulator switches in recess etc. as required(a) 1 or 2 Module ( 75 mm x 75 mm) Cat A |
| 80 | Supplying and fixing following modular switch/ socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required(a) 5/6 A switch Cat A |
| 81 | Supplying and fixing following modular switch/ socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required(d) 3 pin 5/6 A socket outlet Cat A |
| 82 | Supplying and fixing following modular switch/ socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required(c) 15/16 A switch Cat A |
| 83 | Supplying and fixing following modular switch/ socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required(e) 6 pin 15/16 A socket outlet Cat A |
| 84 | 25 mm Rigid PVC bends(Heavy)conforming to IS 9537 |
| 85 | 25 mm Rigid PVC coupler(Heavy)conforming to IS 9537 |
| 86 | 25 mm PVC junction box one way |
| 87 | 25 mm PVC junction box two way |
| 88 | Supply and erecting meter box suitable for three phase energy meter and incoming SP/DP MCB, fabricated out of 16 SWG sheet steel, powder coated, complete as required and conforming to the requirements of Goa Electricity Department. |
| 89 | Supplying and fixing following rating three pole 415 V isolator in the existing MCB DB complete with connections testing and commissioning etc as required(c) 80 A, Cat A |
| 90 | Supply, installation, testing and commissioning of electronic type three phase energy meter (KWh), 4 wire, ISI marked, in polycarbonate or sgheet steel body ( base mounting type) with counter display/LCD display, with ELT, in Class 1.0, 50 Hz, 240 V. AC duly tested by MRT along with Test Certificates, complete as required of following capacity of make L & T only.(c) 50 to 100 A |
| 91 | Supplying and fixing brass batten/ angle holder including connections etc as required. |
| 92 | Supply and erecting of 12 inch (300 mm sweep) exhaust fan with double ball bearings, 1400 rpm, complete with all accessories.(a) Cat A |
| 93 | Supplying and fixing following way TPN sheet steel, double door, Horizontal type MCB distribution board 415 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required (but without MCB/RCCB/Isolator)(k) 12 way (8+36), double door, Horizontal type Cat B |
| 94 | SP MCB, 6 A to 32 A, 10 KA, B series, Cat A |
| 95 | Earthing with GI earth pipe 2 mts long 40 mm dia medium class with ISI mark,of approved brands, including accessories and providing masonry enclosure with CI/RCC cover having locking /lifting arrangement and watering pipe etc. with charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size 1.0x1.0x 2.0 mtrs(min) and disposal of excavated soil. b) Class B GI pipe, 40mm diameter as per specifications. c) Charcoal/salt as per specs (paid seperately). d) Refilling the pit of size 1.0x1.0x 2.0 mtrs(min) with soft black soil of minimum resistivity i/c transportation. e) Masonary chamber with proper foundation, cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe. g) watering arrangement(plumbing will be paid seperately). earthing value to be attached to the pipe. g)watering arrangement(plumbing will be paid seperately).(a) In soily strata |
| 96 | Extra for using salt and charcoal for GI or copper plate earth electrode as required( 96 Kgs of Charcoal and 5 Kgs of Salt) |
| 97 | Providing and laying earth connection from earth lectrode with 4 mm dia copper wire in 15 mm dia GI pipe from earth electrode as required |
| 98 | Supply of 4 core armoured PVC/XLPE insulated, PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) ,IS:7098(Part I) with latest amendments of following size. |
| 99 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, complete as required. |
| 100 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm on surface, etc. complete as required |
| 101 | Providing and Laying Earth Connection from earth Electrode with 4mm dia copper wire in 15 mm dia GI pipe from Earth Electrode as required Please Enable Macros to View BoQ information |