Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | BUILDING PROPER |
| 2 | Carriage of excavated material up to 2 km including loading, unloading & stacking Upto 2 Km. |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil |
| 4 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil |
| 5 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, lift upto 1.5 m. |
| 6 | Supplying and filling in plinth with sand under floors, including watering, ramming,consolidating and dressing complete. |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) |
| 8 | PCC 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 9 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). |
| 10 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) |
| 11 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification. |
| 12 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 13 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 14 | RCC 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm), footing/plinth beam |
| 15 | RCC 1:1.5:3 above plinth in column/coping |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for all heights: :Foundations, footings, bases of columns, etc. for mass concrete |
| 17 | Centering & shuttering for lintels/beams/plinth beams/cantilevers |
| 18 | Centering and shuttering including strutting, propping etc. and removal of form for all heights: Columns, Pillars, Piers, Abutments, Posts and Struts |
| 19 | Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like |
| 20 | Edges of slabs and breaks in floors and wallsUnder 20 cms wide |
| 21 | Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick |
| 22 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick |
| 23 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 24 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500 D or more. |
| 25 | Providing and fixing sheet covering over expansion joints with iron screws as per design Aluminium fluted strips 3.15 mm thick. 200 mm wide |
| 26 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 27 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately). All works upto plinth level |
| 28 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately). All works above plinth level upto floor V level |
| 29 | Add for using extra cement in the items of design mix over and above the specified cement content therein. |
| 30 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 31 | Half brick masonry with common burnt clay F.P.S. (non modular) brick of class designation 7.5 in foundations and plinth in : cement mortar 1:4 (1 cement : 4 coarse sand) |
| 32 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 33 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) |
| 34 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. |
| 35 | Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clayF.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). |
| 36 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble Area of slab over 0.50 sqm |
| 37 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade Area of slab over 0.50 sqm |
| 38 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.a) Marble work |
| 39 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc.,including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. — granite |
| 40 | Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. |
| 41 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 42 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).Second class teak wood |
| 43 | Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). |
| 44 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS : 3818 marked with necessary screws |
| 45 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 46 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 47 | Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). |
| 48 | Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :35 mm thick shutters Kiln seasoned and chemically treated hollock wood |
| 49 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete Fixed to steel windows by welding. |
| 50 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. With 12 mm mild steel U beading |
| 51 | Providing and fixing ISI marked oxidised M.S. single acting spring hinges with necessary screws etc. complete : 150 mm |
| 52 | Providing and fixing oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete :90 mm |
| 53 | Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc. complete.250 mm weighing not less than 150 gms |
| 54 | Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete.75 mm |
| 55 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm |
| 56 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 200x10 mm |
| 57 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper |
| 58 | Providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws, plugs and priming coat on unexposed surface etc. complete 2nd class teak wood. 50x50 mm (base and height) |
| 59 | Providing and fixing cup board shutters with 25 mm thick veneered particle board IS : 3097 marked, exterior grade (Grade I), of approved make, including IInd class teak wood lipping of 25 mm wide x 12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of Engineer-in-Charge.With decorative veneering on one side and commercial veneering on other side |
| 60 | Angle Iron 40*40*5 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete |
| 61 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D, F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 62 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. |
| 63 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc. including cutting, hoisting…(a). Electrical resistance or induction welded tubes |
| 64 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 65 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 66 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube |
| 67 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 68 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick. |
| 69 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 70 | Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. |
| 71 | Extra for Kota stone/ sand stone in treads of steps and risers using single length up to 1.05 metre. |
| 72 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 73 | Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved s;ze, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 74 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm |
| 75 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm |
| 76 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over .. |
| 77 | 12 mm cement plaster 1:6 (1 cement : 6 coarse sand) |
| 78 | 15 mm cement plaster on rough side of single/half-brick wall 1:6 (1 cement: 6 coarse sand) |
| 79 | Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.20 mm cement plaster |
| 80 | 6mm cement plaster of mix 1:3 (1 cement : 3 fine sand) |
| 81 | White washing with lime to give an even shade: New work (three or more coats) |
| 82 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 83 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm |
| 84 | Finishing walls with Acrylic Smooth exterior paint (2+ coats incl. primer) |
| 85 | Applying priming coat:a) With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 86 | b) With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works |
| 87 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work |
| 88 | Painting with aluminium paint of approved brand and manufacture to give an even shade . Two or more coats on new work |
| 89 | Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade :Two or more coats on new work |
| 90 | Providing and applying white cement based putty of average thickness 1mm of approved brand and manufacturer… |
| 91 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4 m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) |
| 92 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built-up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions with required EPDM rubber / neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately).For fixed portion (window frame): Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 93 | For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) — Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15). |
| 94 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge. (Cost of aluminium snap beading shall be paid in the basic item ).With float glass panes of 4.0 mm thickness (weight not less than 10.00 kg/sqm). |
| 95 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 96 | Providing and laying cinder filling in sunken floors and other locations with approved quality cinder including watering and light ramming etc. required for proper compaction/completion of the work complete in all respects as per drawingsand as directed by the Engineer in Charge. |
| 97 | Providing & fixing 0.47mm thick Galvalume sheet roofing including vertical surface fixed with J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead . |
| 98 | Providing and laying 1st quality ceramic glazed Anti skid floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) conforming to IS:15622 in all colours, shades, sizes as approved over 20 mm thick bed of Cement Mortar 1: 4 (1 cement : 4 Coarse Sand) including pointing the joints with white cement and matching pigment etc all complete as directed and specified by the Engineer-in-Cha |
| 99 | Providing and laying Antiskid vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600 x 600 mm) |
| 100 | Cinder filling in sunken floors (water, light ramming) |
| 101 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 150 mm |
| 102 | Providing and fixing aluminium door buffer of approved make, design and colour with necessary screws etc all complete as directed and specified by the Engineer-in-Charge : |
| 103 | Providing and laying 1st quality ceramic glazed Anti skid floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) conforming to IS:15622 in all colours, shades, sizes as approved over 20 mm thick bed of Cement Mortar 1: 4 (1 cement : 4 Coarse Sand) including pointing the joints with white cement and matching pigment etc complete in all respects as per specifications/drawings and to the entire satisfaction to the Architect. |
| 104 | DEVELOPMENT WORKS |
| 105 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed — all kinds of soil |
| 106 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m – Quantity of filling @ 35 % |
| 107 | Random Rubble masonry with hard stone on foundation and plinth including levelling up with cement concrete 1:6:12 ( 1 cement : 6 course sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with- Cement mortar 1:6 |
| 108 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of 5 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete |
| 109 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 110 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. ordinary rock |
| 111 | Earthwork in all kinds of soil up to 3.0 m depth |
| 112 | Earthwork in all kinds of soil up to 4.5 m depth |
| 113 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia |
| 114 | 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 115 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering. All work upto plinth level. 1:5:10 (1 cement : 5 course bound: 10 graded stone aggregate 40mm nominal size) |
| 116 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stoneaggregate 12.5mm nominal size) |
| 117 | Centering and shuttering including strutting, propping etc. and removal of form for all heights – Foundations, footings, bases of columns, etc., for mass concrete |
| 118 | Walls (any thickness) including attached pilasters, butteresses,plinth and string courses etc. |
| 119 | Edges of slabs & breaks (<20 cm) |
| 120 | Centering & shuttering for Suspended floors, roofs, landings, balconies and access platform. |
| 121 | Centering and shuttering for lintels, beams, plinth beams, girders, bressumers, and cantilevers with water-proof ply 12 mm thick. |
| 122 | Providing and fixing tie bolt, spring coil and plastic cone in wall shuttering complete as per the direction of Engineer-in-charge. |
| 123 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level – Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 124 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately). |
| 125 | Brick work with common burnt clay F.P.S. (non-modular) bricks of class 7.5 in foundation and plinth in cement mortar 1:6. |
| 126 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete |
| 127 | 52 mm thick cement concrete flooring with concrete hardener topping under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume. Hardening compound is mixed @ 2 litre per 50kg of cement or as per manufactures specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. for maintaining slope |
| 128 | 12 mm cement plaster finished with floating coat of neat cement (1:4 mix, 1 cement : 4 fine sand) on brick surface |
| 129 | 6 mm cement plaster on rough side of single or half brick wall of mix: 1:3 (1 cement: 3 fine sand) |
| 130 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade – Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 131 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. |
| 132 | Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). |
| 133 | Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc., all complete as per the direction of Engineer-in-Charge |
| 134 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 Cement : 3 coarse sand), including making joints with or without grooves, making drainage openings wherever required, complete as per direction of Engineer-in-Charge. (Precast C.C. kerb stone shall be approved by Engineer-in-Charge) |
| 135 | Providing and fixing soil, waste and vent pipes 100 mm dia. Centrifugally cast (spun) iron socketed pipe as per IS: 3989. Inlet + outlet Vent Pipe |
| 136 | Providing and fixing terminal guard : 100 mm Sand cast iron S&S as per IS - 3989 |
| 137 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 32 mm dia (external work) |
| 138 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work , 40 mm dia |
| 139 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work, 50 mm dia |
| 140 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work, 65 mm dia |
| 141 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work, 80 mm dia |
| 142 | Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : 32 mm dia |
| 143 | Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality 40 mm dia |
| 144 | Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality, 50 mm dia |
| 145 | Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality, 65 mm dia |
| 146 | Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality, 80 mm dia |
| 147 | Providing and filling sand of grading zone V or coarser grade alround the GI pipes in external work., 32 mm |
| 148 | Providing and filling sand of grading zone V or coarser grade alround the GI pipes in external work., 40 mm |
| 149 | Providing and filling sand of grading zone V or coarser grade alround the GI pipes in external work, 50 mm |
| 150 | Providing and filling sand of grading zone V or coarser grade alround the GI pipes in external work, 65 mm |
| 151 | Providing and filling sand of grading zone V or coarser grade alround the GI pipes in external work, 80 mm |
| 152 | Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) : 50 mm |
| 153 | Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. complete (The tail pieces, tapers etc if required will be paid separately) , 80 mm |
| 154 | Gun metal gate valve, 20 mm (screwed end) |
| 155 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm |
| 156 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :, 32 mm |
| 157 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) , 40 mm |
| 158 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) , 50 mm |
| 159 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) , 65 mm |
| 160 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) , 80 mm |
| 161 | Constructing masonry gate valve Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
| 162 | Masonry water-meter chamber (60×45×50 cm) with FPS bricks 7.5 |
| 163 | Providing and fixing G.I. Union in GI pipe including cutting and threading the pipe and making long screws etc. complete(New work),, 25 mm |
| 164 | Providing and fixing G.I. Union in GI pipe including cutting and threading the pipe and making long screws etc. complete(New work), 32 mm |
| 165 | Providing and fixing G.I. Union in GI pipe including cutting and threading the pipe and making long screws etc. complete(New work),, 40 mm |
| 166 | Providing and fixing G.I. Union in GI pipe including cutting and threading the pipe and making long screws etc. complete(New work),, 50 mm |
| 167 | Providing and fixing G.I. Union in GI pipe including cutting and threading the pipe and making long screws etc. complete(New work),, 65 mm |
| 168 | Providing and fixing G.I. Union in GI pipe including cutting and threading the pipe and making long screws etc. complete(New work),, 80 mm |
| 169 | Constructing brick masonry manhole in cement mortar 1 : 4 (1 cement : 4 coarse sand) with RCC top slab with 1 : 2 : 4 mix (1 cement : 2 coarse sand : 4 grade stone aggregate 20mm nominal size); foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1cement 3 coarse sand ) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 (1cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finishd with a floating coat of neat cement complete as per standard design Inside size 90 x 80 cm & 45 cm deep including CI cover with frame (light duty) 455 x 610mm internal dimensions, total weight of cover & frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) With common burnt clay F.P.S.(non modular) bricks of classic designation 7.5 |
| 170 | Extra for depth for manholes: size 90 X 80 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 171 | Constructing Brick Masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top with FPS bricks class designation 75 in cement mortar 1:4 (1 cement : 4 Coarse sand), inside cement plaster 12mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with a floating coat of of neat cement, foundation concrete 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. 0.91m deep with SFRC cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S:12592, total weight of cover and frame to be not less than 182Kg. fixed in cement concrete 1:2:4 mix (1cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) including centering, shuttering all complete.(Excavation foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) with common burnt clay F.P.S.(non module) brick of class designation 7.5 |
| 172 | Extra depth for circuler type manholes 0.91 m internal dia ( at bottom ) beyond 0.91m to 1.67 m . with common burnt clay F.P.S.(non module) brick of class designation 7.5 |
| 173 | Providing and fixing square mouth S. W. Gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 180 x 150 mm. size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 174 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm square bar |
| 175 | Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture’s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. |
| 176 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality LD- 2.5 Rectangular shape 600*450 mm internal dimensions |
| 177 | RCC MH cover & frame HD-20, 560 mm dia |
| 178 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design.With F.P.S. bricks |
| 179 | Domestic Water Supply Submersible Pump |
| 180 | Supply & fixing HDPE double wall corrugated pipe IS 16098 (Part-2) for underground drainage incl. specials, re-excavation & refilling; 200 mm dia |
| 181 | INTERNAL WATER SUPPLY AND SANITARY WORKS |
| 182 | Providing & fixing stone slab table rubbed, edges rounded and polished of size 75 X 50cm deep and 1.8 cm thick fixed in urinal patitions by cutting chase of appropriate width with chase cutter and embedding the stone in chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregste 6mm nominal size) as per Engineer-in-charge and finished smooth White Agaria Marble Stone |
| 183 | Providing and fixing Salem Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with CI brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required. Kitchen sink with drain board, 510X1040mm bowl depth 200mm. |
| 184 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm |
| 185 | Providing and fixing toilet paper holder : C.P. brass |
| 186 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid |
| 187 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in-charge |
| 188 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms.(sink & urinal) |
| 189 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms. |
| 190 | Providing and fixing PTMT towel rail complete with brackets fixed wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms |
| 191 | Providing and fixing CP Brass shower rose with 15 or 20 mm inlet 100 mm diameter |
| 192 | Providing & fixing PTMT towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealed fittings arrangement of approved quality and colour weighing not less than 88 gms |
| 193 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge . a) 15 mm nominal dia. |
| 194 | Providing and fixing uplasticised PVC connection pipe with brass unions 45 cm length 15 mm nominal bore |
| 195 | Providing and fixing C.P. brass bib cock of approved quality confirming to IS:8931 15mm nominal bore |
| 196 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore. 15 mm nominal bore |
| 197 | Providing and fixing wash bashin with C.I. brackets, 15mm dia cp brass singal hole basin mixer of approved quility and make, including painting of fittings and brackets, cutting and making good the walls wherever required - a) White vitreous china wash basin size 550x400 mm with a 15 mm cp brass singal hole basin mixer. |
| 198 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 199 | Providing & fixing PVC waste pipe for sink oncluding PVC waste fitting Complete Flexible Pipe 32mm Dia |
| 200 | Providing and fixing MS holder bat clamps of approved design to cast iron (spun) pipe embedded in and Including cement concrete blocks 10 x10 x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. For 100mm dia. Pipe |
| 201 | Providing and fixing PTMT grating of approved quality and colour Circular type 125 mm nominal dia |
| 202 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) alround CI HUBLESS including bed concrete as per standard design 100mm diameter |
| 203 | Providing, fixing and jointing in position UPVC (SWR) pipe Type-B for soil waste, rain water and vent or antisyphonage pipe of approved make including all fittings (plain or door) e.g. bends, junctions, cowls, offsets, access pieces jointing including fixing the pipe on the wall/ceiling with suitable clamps ,holder bat clamps and anchor fastener of approved design to SWR pipe embedded, cement concrete block 10x10x 10 cm of 1:2:4 ( 1 cement: 4 coarse sand: 4 graded stone aggregate 20 mm nominal size), cutting holes in wall and floors, excavation, refilling and disposal of surplus earth where required and marked good complete etc. and as per direction of Engineer in Charge. 40 mm dia |
| 204 | Providing, fixing and jointing in position UPVC (SWR) pipe Type-B for soil waste, rain water and vent or antisyphonage pipe of approved make including all fittings (plain or door) e.g. bends, junctions, cowls, offsets, access pieces jointing including fixing the pipe on the wall/ceiling with suitable clamps ,holder bat clamps and anchor fastener of approved design to SWR pipe embedded, cement concrete block 10x10x 10 cm of 1:2:4 ( 1 cement: 4 coarse sand: 4 graded stone aggregate 20 mm nominal size), cutting holes in wall and floors, excavation, refilling and disposal of surplus earth where required and marked good complete etc. and as per direction of Engineer in Charge. 50 mm dia |
| 205 | Providing, fixing and jointing in position UPVC (SWR) pipe Type-B for soil waste, rain water and vent or antisyphonage pipe of approved make including all fittings (plain or door) e.g. bends, junctions, cowls, offsets, access pieces jointing including fixing the pipe on the wall/ceiling with suitable clamps ,holder bat clamps and anchor fastener of approved design to SWR pipe embedded, cement concrete block 10x10x 10 cm of 1:2:4 ( 1 cement: 4 coarse sand: 4 graded stone aggregate 20 mm nominal size), cutting holes in wall and floors, excavation, refilling and disposal of surplus earth where required and marked good complete etc. and as per direction of Engineer in Charge. 110 mm dia |
| 206 | Providing and fixing UPVC(SWR) Type-B of size 110 mm x75x40 mm Multi Floor Trap along with 110 mm dia PVC pipe up to floor level and PVC grating of approved make with suitable jointing to ensure leak proof service as per instruction for laying & jointing recommended by the manufacturer and including cement concrete 1:2:4 under and around the multi floor trap where required up to floor level complete in all respects including cutting and making good the walls and floors etc. complete in all respect as per full satisfaction of the Engineer – in – Charge. With 63 mm i/d outlet. ( 110 x 75 x 40) |
| 207 | Providing and fixing UPVC(SWR) Type-B of size 110 mm x 90 mm Nahani Trap along with 110 mm dia PVC pipe up to floor level and PVC grating of approved make with suitable jointing to ensure leak proof service as per instruction for laying & jointing recommended by the manufacturer and including cement concrete 1:2:4 under and around the Nahani trap where required up to floor level complete in all respects including cutting and making good the walls and floors etc. complete in all respect as per full satisfaction of the Engineer – in – Charge. With 90 mm i/d outlet. |
| 208 | Providing and fixing end cap (door piece) of uPVC for cleaning. with 110 OD |
| 209 | Providing and fixing uPVC 110mm P Trap with minimum 50mm water seal with rubber seal on inlet to push fit hopper for indirect waste connections |
| 210 | Providing, fixing, testing and commissioning of pipe inlet fittings fabricated with Upvc with maximum 3 inlets 40, 50 & 75 mm OD size Upvc pipe, fixed to 'P' traps including Dripseal/Pipe seal/solvent /rubber ring joint complete . |
| 211 | Providing and fixing in position 25 mm diameter mosquito proof coupling of approved municipal design. |
| 212 | Providing and fixing CPVC pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge. 15 mm OD |
| 213 | Providing and fixing CPVC pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge., 20 mm OD |
| 214 | Providing and fixing CPVC pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge., 25 mm OD |
| 215 | Providing and fixing CPVC pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge., 32 mm OD |
| 216 | Providing and fixing CPVC pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge., 40 mm OD |
| 217 | Providing and fixing CPVC pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge., 50 mm OD |
| 218 | Providing and fixing CPVC pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the wall same including testing of joints complete as per the direction of engineer incharge concealed work including cutting chases and making good the wall etc., 15 mm OD (incl. chase & making good) |
| 219 | Providing and fixing CPVC pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the wall same including testing of joints complete as per the direction of engineer incharge concealed work including cutting chases and making good the wall etc., 20 mm OD (incl. chase & making good) |
| 220 | Providing and fixing G.I. pipes complete with GI fittings and clamps including cutting and making good the walls etc. (internal work) , 25 mm NB (roof level) |
| 221 | Providing and fixing G.I. pipes complete with GI fittings and clamps including cutting and making good the walls etc. (internal work) , 32 mm NB (roof level) |
| 222 | Providing and fixing G.I. pipes complete with GI fittings and clamps including cutting and making good the walls etc. (internal work) , 40 mm NB (roof level) |
| 223 | Providing and fixing G.I. pipes complete with GI fittings and clamps including cutting and making good the walls etc. (internal work) , 50 mm NB (roof level) |
| 224 | Providing and fixing G.I. pipes complete with GI fittings and clamps including cutting and making good the walls etc. (internal work) , 65 mm NB (roof level) |
| 225 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two more coast on new work |
| 226 | Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends), 25 mm |
| 227 | Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends), 32 mm |
| 228 | Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends), 40 mm |
| 229 | Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends), 50 mm |
| 230 | Providing and fixing gun metal non- return valve of approved quality (PN 1.6), 40 NB |
| 231 | Providing and fixing gun metal non- return valve of approved quality (PN 1.6), 50 NB |
| 232 | Providing and fixing gun metal non- return valve of approved quality (PN 1.6), 80 NB |
| 233 | Providing and fixing brass stop cock of approved quality , 15 mm |
| 234 | Providing and fixing brass stop cock of approved quality 20 mm |
| 235 | Structual steel work welded in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 236 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 237 | Butterfly valve manual, 65 NB |
| 238 | Butterfly valve manual, 80 NB |
| 239 | Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class “O”) insulation on gyeser and solar water pipe suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. 19 mm (geyser/solar pipes) |
| 240 | Providing and fixing GI pipes medium class conferming to IS 1239 with GI fittings including cutting hole chase painted with primer, two coats of enamel paints etc, 80 mm NB (incl. painting) |
| 241 | Providing and fixing brass ball valve with SS 304 Stem and ball, teflon seat complete (PN-40). , 15 mm |
| 242 | Providing and fixing brass ball valve with SS 304 Stem and ball, teflon seat complete (PN-40). , 20 mm |
| 243 | Providing and fixing brass ball valve with SS 304 Stem and ball, teflon seat complete (PN-40). , 25 mm |
| 244 | Providing, fixing, testing and commissioning of motorised butterfly valve of following dia for filling of overhead water tank complete with high and low level control switches to control tanks. The level controllers shall be installed in iverhead tanks. The level switch will close the valve when water level is high in overhead tank and open the valve when overhead water tank level is low. The system should be complete in all respects with accessories 220 V AC / 2 V DC, IP67 electrical water level control unit, copper control wiring in whether proof casing etc. , 50 mm NB (with level control unit, wiring etc.) |
| 245 | Solar water heating system, 300 LPD (thermo-syphon, non-pressurised) |
| 246 | INTERNAL ELECTRIFICATION |
| 247 | Wiring for light point / fan point /exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC Conduit, with modular switch,modular plate ,suitable GI Box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. a) Group C |
| 248 | Wiring for group controlled (looped) light point / fan point /exhaust fan point/ call bell point (without independent switch) with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed Steel Conduit, with modular switch,modular plate ,suitable GI Box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc. as required. |
| 249 | Wiring for twin-control light point with 1.5 sq.mm FRLS Cu cable in PVC conduit incl. 2-way modular switch/plate/GI box & earthing |
| 250 | Wiring for light/power plug 2×4 sq.mm FRLS Cu + 1×4 sq.mm earth in PVC conduit |
| 251 | Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor single core cable in surface/recessed PVC Conduit as required. 2×1.5 sq.mm + 1×1.5 sq.mm earth |
| 252 | Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor single core cable in surface/recessed PVC Conduit as required. 2×2.5 sq.mm + 1×2.5 sq.mm earth |
| 253 | Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor single core cable in surface/recessed PVC Conduit as required. 2×4 sq.mm + 1×4 sq.mm earth |
| 254 | Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor single core cable in surface/recessed PVC Conduit as required. 2×6 sq.mm + 1×6 sq.mm earth |
| 255 | Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor single core cable in surface/recessed PVC Conduit as required. 4×10 sq.mm + 2×6 sq.mm earth |
| 256 | Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor single core cable in surface/recessed PVC Conduit as required. 4×16 sq.mm + 2×6 sq.mm earth |
| 257 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch ,connection etc as required. |
| 258 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 15/16 and 5/6 amps modular socket outlet with shulter and 15/16 amps modular switch connection, etc as required. |
| 259 | Supplying and fixing call bell/ buzzer suitable for single phase ,230 volts ,complete as required. |
| 260 | Medium-class PVC conduit with accessories – 25 mm |
| 261 | Medium-class PVC conduit with accessories – 32 mm |
| 262 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing of 25A modular socket outlet and 25A modular SP MCB \\"C\\" curve including connections painting etc. as required. |
| 263 | Supplying and fixing following way prewired TP & N, MCB distribution board of sheet steel for 415 volts on surface /recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper condutor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isoltor). 4-way (4+12) double door, pre-wired (without MCB/RCCB/Isolator) |
| 264 | Supplying and fixing following way prewired TP & N, MCB distribution board of sheet steel for 415 volts on surface /recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper condutor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isoltor). 6-way (4+18) double door, pre-wired (without MCB/RCCB/Isolator) |
| 265 | Supplying and fixing following way, single pole and neutral, prewired, sheet steel, MCB distribution board, 240 volts, on surface /recess, complete with loose wire box, terminal blocks, duly prewired with suitable size FRLS PVC insulated copper condutor upto terminal blocks, tinned copper bus bar, neutral link, earth bus, din bar, detachable gland plate, interconnections, powder painted including earthing etc as required. (But without MCB/RCCB/Isolator) 8 way, Double door |
| 266 | Supply and fixing 5 amps to 32 amps rating.240/415 volts.'C' curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and commisioning etc.as required a) Single pole |
| 267 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 63 amps |
| 268 | Supplying and fixing following rating, double pole, (single phase and neutral), 230 volts, residual current circuit breaker (RCCB), having a sensitivity 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 40 amps |
| 269 | Cubicle type IP52 LT switchboard with 100A 4P MCCB Incomer, meters/lamps, 150A TPN Al busbar, Outgoings: 9×63A 4P MCB & 3×40A DP MCB, complete |
| 270 | Supplying and fixing of following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required. a) 75 mm x 75 mm x 60 mm deep |
| 271 | Supplying and drawing following pair, 0.5.mm dia FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair |
| 272 | Supplying and fixing following modular switch/ socket on the existing modular plate and switch box including connections but excluding plate etc .as required. a) Telephone socket outlet |
| 273 | Supplying and fixing following modular switch/ socket on the existing modular plate and switch box including connections but excluding plate etc .as required. b) TV socket outlet |
| 274 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 275 | Supplying and fixing of the following sheet steel clad wall / recess mounting telephone tag blocks of krone make constructed from 14 SWG sheet steel finished with red oxide coating of two coats of paint with hinged gasketted powder coated door and complete., 5-pair |
| 276 | Earthing with G.I earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtr long etc. with charoal or coke and salt as required. |
| 277 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 278 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 279 | 25×5 mm GI strip on surface/in recess for connections |
| 280 | 6 SWG GI wire on surface/in recess for loop earthing |
| 281 | Supllying, Installation, Testing & commisioning of following type LED reccesed/surface mounted light fixture made of Aluminium die cast, proper heat sink, minimum 90Lm/W complete in all aspects as mentioned in this tender. With 5 Years Warranty on LED and Driver a) 15W LED DOWNLIGHTER |
| 282 | Supllying, Installation, Testing & commisioning of following type LED reccesed/surface mounted light fixture made of Aluminium die cast, proper heat sink, minimum 90Lm/W complete in all aspects as mentioned in this tender. With 5 Years Warranty on LED and Driver 18 W LED tubelight |
| 283 | Supllying, Installation, Testing & commisioning of following type LED reccesed/surface mounted light fixture made of Aluminium die cast, proper heat sink, minimum 90Lm/W complete in all aspects as mentioned in this tender. With 5 Years Warranty on LED and Driver 20 W LED tubelight |
| 284 | Supllying, Installation, Testing & commisioning of following type LED reccesed/surface mounted light fixture made of Aluminium die cast, proper heat sink, minimum 90Lm/W complete in all aspects as mentioned in this tender. With 5 Years Warranty on LED and Driver Bracket light |
| 285 | Supplying of 305 mm 1400 RPM exhaust fan complete with louver and bird guard screen with 3 core flexible wire as required. |
| 286 | Supplying of ceiling fan, complete with blades with suitable length of down rods shackle insulator earthing point including connection etc . as required. |
| 287 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 288 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 289 | Installtion of exhasut fan up to 450 mm sweep in the existing opening, including making the hole to suit the size of the abvoe fan, making good the damage, connection testiing and commissioning etc as requried |
| 290 | Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. |
| 291 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc.as required. |
| 292 | Supplying fitting and fixing of copper lightning arrestor with 5 nos finger at the top & copper base plate at the bottom completeb) with 5ft high copper rod |
| 293 | Building PanelFabrication, supply , installation, testing and commissioning of cubicle type compartmentalized pedestal/ floor mounted Power Supply Panel Board of approved size and 450mm deep made out of 2mm thick CRGA sheet steel with suitable size compartments, Al bus bar, swutchgears, voltmeters, ammeters with selector switches etc incl powder coating painting with accessories, hardwares etcIncoming63Amp MCCB TP 35 KA…..1 NOIndication light R,Y,B….3 nosBUS-BAR FEEDERS100Amp Aluminum bus-bar TPN..1 setOut going16-32Amp MCB TPN 10KA ….12 nos32Amp MCB TPN 10KA (SPARE)..1 noSpace for three phase meterEmergency SectionIncoming32Amp MCB DP 10KA …1 nosOut going25Amp MCB DP 10KA.....2 nos32Amp MCB DP 10KA....1 nosENCLOSURE...1 SET650*500*150 (4 SFT)PANEL BODY FABRICATED IN 14/16 SWG CRCA SHEET , POWDER COA- TED IN SIEMENCE GREY COLOUR COMPLETE IN ALL RESPECTS UNIVERSAL GLAND PLATES. |
| 294 | Building PanelFabrication, supply , installation, testing and commissioning of cubicle type compartmentalized pedestal/ floor mounted Power Supply Panel Board of approved size and 450mm deep made out of 2mm thick CRGA sheet steel with suitable size compartments, Al bus bar, swutchgears, voltmeters, ammeters with selector switches etc incl powder coating painting with accessories, hardwares etcIncoming125Amp MCCB TP 35 KA…..1 NOIndication light R,Y,B….3 nosBUS-BAR FEEDERS150Amp Aluminum bus-bar TPN..1 setOut going63Amp MCB TPN 10KA ….5 nos63Amp MCB TPN 10KA (SPARE)..1 noEmergency SectionIncoming63Amp MCB DP 10KA …1 nosOut going25Amp MCB DP 10KA.....5 nos32Amp MCB DP 10KA....1 nosENCLOSURE...1 SET1050*1450*150 (17 SFT)PANEL BODY FABRICATED IN 14/16 SWG CRCA SHEET , POWDER COA- TED IN SIEMENCE GREY COLOUR COMPLETE IN ALL RESPECTS UNIVERSAL GLAND PLATES. |
| 295 | EXTERNAL ELECTRIFICATION |
| 296 | OUTDOOR FEDDER PILLAR PANELFabrication, supply , installation, testing and commissioning of cubicle type compartmentalized pedestal/ floor mounted Power Supply Panel Board of approved size and 450mm deep made out of 2mm thick CRGA sheet steel with suitable size compartments, Al bus bar, swutchgears, voltmeters, ammeters with selector switches etc incl powder coating painting with accessories, hardwares etc(a) Panel board shall house 1 nos 4 pole 200A MCCB, 20kA as Supply Incomer, 4 pole 200A Al Bus Bar, 3 nos CT of 200/5A, 1 nos Ammeter with selector switch, 1 nos 0-500V Voltmeter with selector switch, 3 nos LEDs indicating lamps, 4 nos 4 pole 200 A MCB, 25kA as outgoing feeders |
| 297 | Lighting PanelIncoming63Amp MCCB TP 35 KA…..1 NOIndication light R,Y,B….3 nosBUS-BAR FEEDERS100Amp Aluminum bus-bar TPN..1 setOut going25Amp MCB DP 10KA ....1 noEmergency SectionIncoming32Amp MCB DP 10KA …1 nosOut going16Amp MCB DP 10KA....4 nosENCLOSURE...1 SET900*1150*2000 (9 SFT)(With Timer Switch)PANEL BODY FABRICATED IN 14/16 SWG CRCA SHEET , POWDER COA- TED IN SIEMENCE GREY COLOUR COMPLETE IN ALL RESPECTS UNIVERSAL GLAND PLATES. |
| 298 | Supply 2×6 sq.mm Al. armoured cable (28 mm) |
| 299 | Supply 4×10 sq.mm Al. armoured cable (28 mm) |
| 300 | Supply 3½×50 sq.mm Al. armoured cable |
| 301 | Supply 3½×120 sq.mm Al. armoured cable |
| 302 | Supply 3½×150 sq.mm Al. armoured cable |
| 303 | End termination for 2 X 6 sq. mm (28mm) |
| 304 | End termination for 4 X 10 sq. mm (28mm) |
| 305 | End termination for 3½ X 120 sq. mm (45mm) |
| 306 | End termination for 3½ X 150 sq. mm (50mm) |
| 307 | Supplying and Installaion of 45 W LED post top light IP65 (≥4,500 lm), complete |
| 308 | Supplying and Installaion of 45 W LED street light IP66 (≥4,500 lm), complete, materials fabrication & erection of street light poles 4metres high stepped made of heavy gauge IC pipe of a combination of 60mm & 38mm and 150mm dia. with 300x300mm base plate fixed in grand with 1.3metre concrete puff projecting 500mm outside the ground |
| 309 | Supplying and Installaion of 200×150×125 mm polycarbonate IP55 junction box with SP MCBs & TB |
| 310 | Supplying and Installation of Cable through GI pipe to JB & 2×2.5 sq.mm Cu wiring from JB to fixture |
| 311 | FIRE FIGHTING |
| 312 | Supplying and Installation of Fire extinguisher — CO₂ type, 4.5 kg, ISI marked, with hose & wall bracket |
| 313 | Supplying and Installation of Fire extinguisher — ABC powder type, 6 kg, ISI marked, with gauge, valve & wall bracket Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |