| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC Conduit, and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Make Havells life line life guard /Polycab) |
| 2 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire |
| 3 | 2 x 4 sq. mm + 1 x 4 sq. mm earth wire |
| 4 | Providing & Fixing of IP40 LED Recessed / Surface Mounted, Round / Sqaure Non-Dimmable Back lit SMD Mid Power LED Downlight with die-cast aluminum housing & Heat Sink for heat dissipation with UV Stabilized non yellowish Diffuser with internal/ external BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% and in compliance to IEC standards. System Lumen efficacy of ≥ 120 lm / watt, THD < 10 % ,p.f.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted.12 W CEILING MOUNTED LED LIGHT |
| 5 | Supply installation/testing and commissioning of LED flood light 50W with complete accessories (Make Havells/Philips/Panasonic/Syska/Gold medel) |
| 6 | P/F of exhaust fan shutter type of sweep 250mm in the existing opening, including making the hole to suit the above fan, making good the damage as required.(Make: Havells USHA/Bajaj)Supplying and fixing of 25mm PVC conduit capping along with accessories in surface/recessed including cutting the wall and making good the same in case of recessed conduit as required. |
| 7 | S/F following size/module, GI box along with modular base and cover plate for modular switches/sockets in recess etc. as required: (Make: Havells Crabtree/Legrand/Greatwhite/CONA/Gold medel) 3 Module |
| 8 | 6 MODULE |
| 9 | 12 MODULE |
| 10 | S/F following modular switch/socket on the existing modular plate and switch box including connection but excluding modular plate etc. as required. (Make: Havells Crabtree/Legrand/Greatwhite/CONA/Gold medel) 6/10 A switch |
| 11 | 6 pin 15/16 A socket outlet |
| 12 | indicator lamp |
| 13 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) 24 Way double door SP&N |
| 14 | S/F of 5 Amps to 63 Amps, 240/415V, “B series, ISI Mark” miniature circuit breakers suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required: (Make: Havells/C&S/V Guard) single pole 6/10 A, SP MCB |
| 15 | Single pole 16/20 A, SP MCB |
| 16 | Double pole 25A SP MCB |
| 17 | Double pole 63A DP MCB |
| 18 | Fabrication, Supplying , Instalation testing and commissioning of following pannel made out of 2mm thick MS Sheet Floor mounted Vermin and dust proof indoor duly painted with provision for fixing of 1 no incomer MCCB. MCCB type change iver switch 1no including supply and fixing 2 set of Aluminium bus bar and strip for housing MCB56nos MF digital Metre and allied accessories as required (make as per annexure |
| 19 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25mm |
| 20 | Supplying and fixing of 10 x 10 x 10 Cm of Concealed box |
| 21 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. |
| 22 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 23 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 24 | Providng & fixing of Changeover of required specificatioon comnplete job(Liver Type) |
| 25 | Supply of 1100 volt grade aluminium conductor KPLE insukated pvc sheath arranged complete as per specification as required 25 sqm |
| 26 | Supply and installation of electric heater heavy voltage with two heat out put settings 1400 watts x 2=2900watts, over heat protection ,thermostatically controlled detachable wall mounting bracket,digital LED display room tempertaure sensor etc with isi marked or equivalent. |
| 27 | Supply and installation of solar light of approved and certification by MNRE(GOI) with following conditions: 1) PV module- 75 Wp under STC. 2)Battery – Minimum 12 V , 30 AH capacity Lithium iron phosphate (LifePO4). 3) Light Source- White Light Emitting Diode (W-LED). 30-watt, W-LED luminaire, dispersed beam, soothing to eyes with the use of proper optics and diffuser. LED chip should be compliance to IES: LM-80 (Approved method of measuring Lumen Maintenance for LED light sources and LED lumen depreciation time to L70). Test report for the same should be submitte 4) Light Output- The luminaire must use high efficacy W-LED with minimum 150 lumens per watt (and UV free). [ A certificate to be submitted by the system supplier to the test lab during certification.]For single light level- minimum 15 Lux when measured at a point4 metres below the light. The illumination should be uniform without dark bands or abrupt variations and soothing to eye. Higher light output will be preferred.For multiple Light levels- The luminaire should have two levels of light to take care of different lightning needs during the night. Minimum 15 Lux when measured at a point 4 metres below the light ( at “ high illumination level”). The illumination should be uniform without dark bands or abrupt variations. Minimum 5 Lux at lower illumination levels. (Higher light output will be preferred).The luminaire shall be tested for Electrical, Photometry and Color parameters as per IES LM-79:2008 or IS: 16106:2012 for following Performance parameters like :a) Total luminous flux: >=3000 lm.b) Luminous efficacy (i.e system efficacy): >=150lm/W.c) Colour temperature : Between 5500 K to 6500 K.d) CRI >=70.e) Luminous intensity distribution should follow the batwing patterns in polar curves.f) Require validation report using .ies file, which is generated during luminous intensity distribution test and using maintenance factor 0.9 and pole height of 4 m, road width 5m and pole span 15 m. The average illuminance level and uniformity should comply with requirements as per IS:1944, wherever applicable.5) Mounting of Light: Pole height 5m above the ground level and 1 m below the ground. Luminaire shall be at least 4.5 m above the ground level. The diameter of pole should be 75-76 mm and the thickness 2-3 mm. 6)Electronics Efficiency- Overall total efficiency of the electronics should be Minimum 90%. |
| 28 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 29 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 30 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests. |
| 31 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357mm |
| 32 | Providing and fixing C.P Brass toilet paper holder |
| 33 | Providing and fixing of Soap Dish (C.P Brass) with brackets etc |
| 34 | Providing and fixing brass bib cock of approved quality. 15mm nominal bore. |
| 35 | Providing and fixing flow trap of PVC . |
| 36 | Providing and fixing floor jail. |
| 37 | Providing and fixing soil, waste and vent pipes 110mm dia PVC. |
| 38 | Providing and fixing soil, waste and vent pipes 90mm dia PVC. |
| 39 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes SDR7.4 U V stabilized & anti -microbial fusion welded, having thermal stability for hot & cold water supply including all PP - R plain & brass threaded polypropylenerandom fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer in Charge. (Internal workexposedon wall)25mm |
| 40 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and color. 600 mm long towel rail with total length of 645 mm, 78 mm wide and effective height of 88 mm, weighing not less than 190 gms. |
| 41 | Providing and fixing of plain bends of required degree.110mm dia PVC. |
| 42 | Providing and fixing of plain bends of required degree.90mm dia PVC. |
| 43 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
| 44 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 45 | Providing nad fixing white vitreous china pedestal for wash basin completely recessed at the back or the reception of pipes and fitting |
| 46 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete Flexible pipe 40 mm dia |
| 47 | providing and fixing PPR Unions 32mm |
| 48 | Stone tile work for wall lining upto 10 m height with special adhesive over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement with an admixture of pigment to match the stone shade.Raj Nagar plain white marble/ Udaipur green marble/ Zebra black marble Kitcehn Slab |
| 49 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes SDR7.4 U V stabilized & anti -microbial fusion welded, having thermal stability for hot & cold water supply including all PP - R plain & brass threaded polypropylene random fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer in Charge. (Internal workexposed on wall)32 mm |
| 50 | Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes SDR7.4 U V stabilized & anti -microbial fusion welded, having thermal stability for hot & cold water supply including all PP - R plain & brass threaded polypropylenerandom fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer in Charge. (Internal workexposedon wall)40mm |
| 51 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 52 | Providing and fixing of material for the insulation of Water Storage Tank of with nitrile sheet, tapping with cello tape, Rockwood 6 inch per side, wire mesh, polythene, aluminum sheet 26 gauge cladding with dia of, complete job. 19 mm thick nitrile sheet |
| 53 | Providing and fixing of material for the insulation of pipe with nitrile tube, tapping with cello tape for inner wall fittings. complete job including carriage. 19 mm thick, 50 mm dia (OD) (PPR 25 mmm) |
| 54 | Providing and fixing of material for the insulation of pipe with nitrile tube, tapping with cello tape for inner wall fittings. complete job including carriage. 19 mm thick, 50 mm dia (OD) (PPR 32 mmm) |
| 55 | Providing and fixing heat tape 33 Watt on PPR pipes made of denforced or chromelox or equivalent make, as approved by Engineer In Charge, complete Job |
| 56 | Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink as per IS 13983with C.I. brackets and stainless steel plug 40 mm including painting of fittings andbrackets, cutting and making good the walls wherever required:Kitchen sink without drain board 610x510 mm bowl depth 200 mm. |
| 57 | Providing and laying 40mm thick faciory made cement in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 58 | Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to1.5 m.All kinds of soil |
| 59 | Drilling of 125mm dia Hand Pump Well in collapsible strata conglomerate, boulders, gravel, pebbles, silt, clay, rock etc formation whatsoever encountered atsite. The job envisages construction of Hand Pump Wells of an avg. depth of 60 Mtrs. below ground Level, or till the sufficient discharge of water is available fromthe bore hole by way of Drilling of 125mm Bore Holes using 115mm ODX method and exploration of underground potable water by tapping sufficient aquifer zoneswith simultaneously lowering of 125mm M.S/G.I. plain ended pipe duly chamfered and welded. The job includes all charges on account of cost of drilling/accessories/ tools/ attachments/ bits/ POL’s/ consumable/ labour etc with carriage of all materials upto site of work, including cost of suitable casing pipe (ISImarked steel tubes for water wells of hot types finished seamless (HFC) electric automatic fusion welded (HFC ) resistance welded in length of 3Mtr withtolerance of +_ 10cm beveled casing 125mm dia nominal bore with 4.5mm thickness/shoe of adequate hardness. The job also includes development of drilled bore holes with Air Compressor of suitable capacity to clear the tapped water from all suspended impurities.125 mm dia DTH Depth ( Drilling beyond 60M Depth) |
| 60 | Transportation of boring equipment /machines/tools and plants to the new site of bore works. Fixing of complete camp by way of erecting of equipment, machine,tools accessories, attachment, fixing of tents for labours and stacking of required material at bore site. The job also includes leveling of the ground drillingmachines and other transportation of POL etc. |
| 61 | Providing,installation and successful commissioning of suitable open well submersiblepump of 2-3 LPS at head 90mtr make of crompton and greaves or KSB company with panel box 3core 16sq-mm including water proffing cable100mtr/safety cable6mm thick 150mtr as perrequirment with carriage upto site of workcomplete job. The included 5k servo stabiliser ,box for control panel and also included civil n mech work to make system functional As per site engineer. |
| 62 | Supply and installation of Gyser of approved brand and quality complete Job Please Enable Macros to View BoQ information |