| 1 | [11.69.2]Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. 2. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre [Through Rate] |
| 2 | [11.78]Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. [Through Rate] |
| 3 | [23.22.1.10]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.10. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 125 to 160 amp, 25 KA [Through Rate] |
| 4 | [23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole [Through Rate] |
| 5 | [23.26.2]SAFETY ITEMS 2. Supply and erection of High Tension Voltage caution notice plate of size 250*200 mm in three languages. [Through Rate] |
| 6 | [23.27.1]Supply and erection of Godrej Almirah typeM.S. pedestal made of 50 mm x 50 mm x 6 mm angle iron frame with 3.00 mm thick M.S. sheet covering including shutters with suitable hinges and locking arrangement with Godrej type handle including round bars . The top covering should have downward overhang of 75 mm on all sides of pedestal , having two sets of water proof ventilation holes of suitable size on the sides , at top and bottom , each set containing four Nos. holes to discharge the heat produced by the current . The shutters fixed with rubber gasket of superior quality and of suitable size to make it water proof . The pedestal duly painted both inside and outside with two coats of approved paint and primary coat and its legs are embeded upto the entire depth in 1:2:4 cement concrete block , projected 75 mm all around the pedestal and and 200 mm above the ground level including the cost of all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work:- 1. M.S. pedestal of size 600 mm wide , 750 mm high ,300 mm deep and bottom totally open , duly embeded in 1:2:4 cement concrete block of size 750 mm x 450 mm x 200 mm above ground level , having a base of size 900 mm x 600 mm x 250 mm below ground level. 0 0 [Through Rate] |
| 7 | [24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. [Through Rate] |
| 8 | [24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. [Through Rate] |
| 9 | [24.1.7]EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. [Through Rate] |
| 10 | [24.13.32]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 32. 25 Sq mm 4 core (Arm.) [Through Rate] |
| 11 | [24.2.1]LT CABLE 1. Supply & erection of LT phase separator on LT line complete in all respect up to entire satisfaction of the Engineer-in-charge of the work. [Through Rate] |
| 12 | [24.2.8.10]LT CABLE 8.10. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 120 sqmm [Through Rate] |
| 13 | [24.2.8.14]LT CABLE 8.14. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work.300 sqmm [Through Rate] |
| 14 | [34.3.2]Printing New Letter and Figures of any ShadePrinting new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade 2. English and Roman (Hyphens not to be paid) [Through Rate] |
| 15 | Supply, installation, testing, commissioning of 3 Phase 11KV/0.433 KV-250V, 200 KVA Oil immersed, naturally cooled, Aluminum Wound Outdoor type Distribution Transformers with CSP (Completely self protected ) features with external microprocessor based four pole MCCB 300 Amp. To 400Amp., 50kA strictly conforming to Nigam’s technical specification No. CSC-V/R-I/DH/UH/P and D/2010-2011 read with amendment thereof and as per relevant ISS as amended from time to time and losses conforming to 4 star rating of BEE as per Appd. Make and Specification of UHBVN/UHBVN including installation of transformer on existing platform up to the entire satisfaction of Engineer-in-Charge. (Excluding GST 18%)Voltage Rated Frequency Permitted at 75ºCi) Maximum load losses at 50% load at 75ºC = 780 Watt ii) Maximum losses at 100% load at 75ºC = 2300 Wattiii) Warranty = 72 Months shall be one time The above losses are maximum allowable and there would not be any positive tolerance. (Excluding GST 18%) |
| 16 | Supply and Erection of 11 kV G.O. Switch vertical mounted with a heavy duty 9 Nos. post insulators suitable copper male and female contacts fixed on GI angle frame with G.I. Nut and Bolts including G.I. pipe and operating handle complete in all respect (Excluding GST 18%) |
| 17 | Supply and erection of 11kV Lightning Arrester as per approved makes and relevant specifications of UHBVN complete fixing with GI clamp, Nut and bolts up to entire satisfaction of Engineer-In-Charge (Ex-GST 18%) |
| 18 | Supply and Erection of 11kV polymeric Pin insulator 10 kN with GI Pin of approved makes / specification of UHBVN (Ex-GST 18%) |
| 19 | Supply and Erection of ACSR conductor 100 mm2 conforming to IS 398 (Part-II) 1976/1996, IS 4826-1976 IS 1521-1972 and IS 1778-1980 with latest amendments as per UHBVN specification including stringing and sagging as well as jointing and binding with insulators at supports complete in all respect upto the entire satisfaction of Engineer-in-Charge (Ex-GST 18%) |
| 20 | Supply and Erection of ACSR conductor 80 mm2 conforming to IS 398 (Part-II) 1976/1996, IS 4826-1976 IS 1521-1972 and IS 1778-1980 with latest amendments as per UHBVN specification including stringing and sagging as well as jointing and binding with insulators at supports complete in all respect upto the entire satisfaction of Engineer-in-Charge (Ex-GST 18%) |
| 21 | Supply and Erection of ACSR conductor 30 mm2 PVC insulated conforming to IS 398 (Part-II) 1976/1996, IS 4826-1976 IS 1521-1972 and IS 1778-1980 with latest amendments as per UHBVN specification including stringing and sagging as well as jointing and binding with insulators at supports complete in all respect upto the entire satisfaction of Engineer-in-Charge (Ex-GST 18%) |
| 22 | Supply and Erection of LT PVC unarmoured cable of size 300 mm2 single core with aluminium conductor 650/1100 V conforming to ISS 1554 (Part-I) of 1988 IS: 7098/Part-1/ 1988 with latest amendments up to entire satisfaction of Engineer-in-charge (Make: Grandlay, Polycab, Havells, CIRTINA/Gemscab (Ex-GST 18%) |
| 23 | Supply and Erection of fuse unit of L.T. side suitable for 200 kVA transformer complete with wooden board, aluminium bus bar GI clamps and GI nut and bolts including all petty material required up to the entire satisfaction of Engineer-in-charge (Ex-GST 18%) |
| 24 | Supply and erection of L.T. Aerial Bunched cable of size 120 Sqmm, 4 core plus 95 Sqmm including making of necessary connection to make Polycab, Havell’s, Grandlay/Gemscab complete in all respect up to the entire satisfaction of Engineer-in-charge. (Ex-GST 18%) |
| 25 | Supply and Erection of 9Mtr. Long PCC pole as per IS:1678-1960 specifications,9Mtr. Long 105mm x 115mm at top and 105mm × 315mm at bottom with a working load of 200 Kg. buried 1.80 M in ground or as UHBVNL specification. (Ex-GST 18%). |
| 26 | Supply and Erection of 11 Mtr. Long PCC pole as per IS:1678-1960 specifications,11Mtr. Long 140mm x 200mm at top and 140mm × 400mm at bottom with working load of 400 Kg buried 2.20 M in ground as per UHBVNL specification.(Ex-GST 18%). |
| 27 | Supply and Erection of Stay set for HT line complete with GSS 7/8 SWG, Egg, insulator/ Disc Insulator, GI rod 20mm dia threaded up to 250mm length with Nut (wt.6.224kg), cross plate 460 mm of Channel 75×40×6mm (wt.5.330kg), Elbow (wt.2.240kg), clamp with Nut-Bolts etc. as per UHBVN specification complete in all respect up to the entire satisfaction of Engineer-in-charge. (Ex-GST 18%). |
| 28 | Supply and Erection of Stay set for LT line complete with GSS 7/8 SWG, Egg, insulator/ Disc Insulator, GI rod 20mm dia threaded up to 250mm length with Nut (wt.6.224kg), cross plate 460 mm of Channel 75×40×6mm (wt.5.330kg), Elbow (wt.2.240kg), clamp with Nut-Bolts etc. as per UHBVN specification complete in all respect up to the entire satisfaction of Engineer-in-charge. (Ex-GST 18%). |
| 29 | Supply and Erection of HT Cradle Guard made of GI wire of SWG including fixing in 11kV line complete in all respect up to the entire satisfaction of the Engineer-In-Charge. (Ex-GST 18%). |
| 30 | Supply and Erection of LT Cradle Guard / Guard Reel made of GI wire of SWG including fixing in 11kV line complete in all respect up to the entire satisfaction of the Engineer-In-Charge. (Ex-GST 18%). |
| 31 | Supply and Erection of Galvanized steel item (Flat, Angle, Channel) and Nut and Bolts etc. including cutting, bending to the required shape, drilling hole, carriage, loading-unloading complete in all respect up to the entire satisfaction of Engineer-in-charge.(Ex-GST 18%). |
| 32 | Supply, Stringing and Sagging 8 SWG G.I. Earth wire complete in all respect to the entire satisfaction of Engineer-in-charge conforming to IS 298/1978 and 7807/1973 and with latest amendment thereof. (Ex-GST 18%). |
| 33 | Supply and Erection of shackle insulator as per UHBVN specification complete in all respect (Ex-GST 18%) |
| 34 | Supply and erection of bracket 1 Mtr long made of 32mm dia (Nominal), medium gauge G.I. pipe for fixing of street light fitting on 9 Mtr long PCC poles including cost of 6 Nos. GI nut and bolts with two nos. clamps made of 50x6mm GI flat complete in all respect upto the entire satisfaction of the Engineer-in-charge (Ex-GST 18%) |
| 35 | Supply and erection of bracket 1 Mtr long made of 40mm dia (Nominal), medium gauge G.I. pipe for fixing of street light fitting on 9 Mtr long PCC poles including cost of 6 Nos. GI nut and bolts with two nos. clamps made of 50x6mm GI flat complete in all respect upto the entire satisfaction of the Engineer-in-charge (Ex-GST 18%) |
| 36 | Supply and Erection of ACSR Conductor 50 sqmm complete in all respect with all accessories as per approved makes and specification of UHBVN. |
| 37 | Supply and Erection of PG Clamp for 100 sqmm ACSR Conductor complete in all respect with all accessories as per approved makes and specification of UHBVN. |
| 38 | Supply, erection, testing and commissioning of ELEX-TWS-2EXT/Amson`s/LandT make Automatic electric timer to switch ON/OFF the street light automatically. It should have adjustable lux level switch, with extensible mountable sensor. It shall change ON/OFF timing automatically as per lux level of the Sun at sun-rising and sun setting, throughout the year. Shall have two Nos. LandT make, 3 pole power contactor model MNX-70 to control 70 amp per phase with 220 Volt coils. It shall have auto/manual switch for repair of street light during day time. The whole unit components to be assembled on Bakelite sheet with 16 amp capacity MCB to save the time switch. The erection of the complete unit in the existing pedestal with complete wiring upto the entire satisfaction of the Engineer-in-charge. (Excluding GST) |
| 39 | Supply and erection of 11KV polymeric disc insulator 45 KN BandS type with fitting complete in all respect with all accessories as per approved makes and specification of UHBVN. |
| 40 | Supply and Erection of Barbed wire complete in all respect with all accessories as per approved makes and specification of UHBVN. |
| 41 | Supply and Erection of D-strap made out of M.S Flat of size 40 x 6mm suitable for LT insulator 90 x75mm with latest amendments complete in all respect upto the entire satisfaction of Engineer-In-Charge. |
| 42 | Supply and Erection of wooden cleat for HT XLPE cable complete in all respect with all accessories as per approved makes and specification of UHBVN. |
| 43 | Supply and Erection of 70/72 Watt Street light luminaire with multiple LED with lighting efficient with power LED light with lens pressure die cast aluminum housing, reflector and enclosed with polycarbonate/ toughened glass, IP-66 level, having light efficiency of 120 lumens / watt up to the entire satisfaction of Engineer-in-charge of the work (with 3 year free replacement warranty, mtc. including labour charges, free of cost) Make: Philips / Bajaj / Panasonic / LT (Ex-GST 18%) |
| 44 | Supply and Erection of 25 Watt pressure die cast aluminum housing LED street light fitting luminaire with multiple LED lenses and heat resistant polycarbonate. Cover glass IP65 of complete in all respect as per specifications having light efficiency of 120 lumens / watt up to the entire satisfaction of Engineer-in-charge of the work Make: Bajaj / Philips / LT/Panasonic (with 3 year free replacement warranty, mtc. including labour charges, free of cost). (Ex-GST 18%) Please Enable Macros to View BoQ information |