| 1 | Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sidesand ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres All kinds of soil |
| 2 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) |
| 3 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills,fillets etcupto floor V level, including curing but excluding the cost of centring, shuttering and finishing with 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 4 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc.complete 40mm thick with 20 mm nominal size stone aggregate. |
| 5 | Centering and shuttering including strutting, propping etc. and removal of form work for Foundations, footings, bases for columns |
| 6 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws |
| 7 | Providing / fixing powder coated aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z- sections and other sections of approved make conforming to IS :733 and IS :1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC / neoprene felt etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C. P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer in charge (including glazing and paneling)for shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required including all fittings complete 16 guage |
| 8 | Regrading terracing of mud phaska covered with tiles or bricks, in cement by dismantling tiles or bricks, removing mud plaster, preparing the surface of mud phaska to proper slope, relaying mud plaster gobri leaping and tiles or bricks, grouted in cement mortar 1:3 (1 cement: 3 fine sand), including replacing unserviceable tiles or bricks with new ones anddisposal of unserviceable material to the dumping ground (the cost of the new tiles or brick excluded) within 50 meters lead. |
| 9 | Cost of new tiles @ 35 tiles / sqm |
| 10 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement: 3 fine sand) as per standard design. In 75x75 mm deep chase. |
| 11 | Providing and fixing of 3mm thickness APP (Atactic Poly Propylene Polymer ) Superthermoly STP sheet polyester based sheet black finishing including coats of silver paint with cemented surface by following method cleaning the surface with wire brush to make the surface free from all loose particles, dust etc then repairing / making the corner fillets dips with pidicrete URP 301 or equivalent water proofing compound in cement and sand mortar 12mm to 18mm thick and with PCC 1:2:4 mix. (I) Applying with shalitex STP primer for bitumen membrane @ 0.40 ltr/sq. mt. (II) Mt. by the 3mm thickness APP superthermoly STP black sheets polyester based sheet black finishing manufacture (III) Cut 1\\" deep groove above the roof surface on the groove with polymer modified mortar (IV) in case of low height parapets, terminate APP superthormoly STP polyester sheets pver the parapet (V) for over lapping of joints, rub the polythylene side of membrane by wire brush, apply shali bond APP over the ribbed area, alow it to the tackly and then fix the bitumenious side of APP superthermolySTP sheet polyester with hot application (VI) for longitudinal and tranverse joint pverlaps of 75mm and 100mm respectively id desired. the vital physical and chemical paramater of the membrane shall as under:- Siftening ppoint of membrane not less them 150*c cold flexiblity shall be upto 0\\"c when tested in accordance with ASTM, joint strengh in longitudunal and transverse direction at 1223*c as 350/300N/5cm. Tear strenght in longitudinal and transverse direction as 60/80N in 3mm thick, the weight of roll (40KG for 1 mtr bt 10 mtrs) the laying of membrane shall be got done through the certified applicator. |
| 12 | Repairs to plaster of thickness 12mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 meters lead With cement mortar 1:4 (1 cement : 4 fine sand) |
| 13 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 14 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface toprepare the surface even and smooth complete 2 mm thick |
| 15 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer |
| 16 | Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound) content less than 50 grams/ liter, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour Two coats |
| 17 | Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm) |
| 18 | Finishing walls with Acrylic smooth exterior paint of required shade Old work (two or more coats applied @ 1.67 liters/10sqm on existing cement paint surface) |
| 19 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade, one or more coats on old work. |
| 20 | Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion (i) Single socketed pipes |
| 21 | 110 mm diametre |
| 22 | 75 mm diametre |
| 23 | Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. |
| 24 | Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931 |
| 25 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 |
| 26 | Providing and fixing PTMT grating of approved quality and colour Circular type 125 mm nominal dia with 25mm waste hole |
| 27 | Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements,weighing not less than 106gms. |
| 28 | Providing and fixing 600x120x5mm glass shelf with edges round off supported on anodized aluminum angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs, etc. complete |
| 29 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 453x357 mm |
| 30 | Providing and fixing un plasticized P.V.C. connection pipe with PTMT nuts, collars and bush of approved quality and colour 15 mm nominal bore with 45 cm length. |
| 31 | Providing and fixing of 35 liter water heater Geyser of approved make Racold, Havells, Cropmton or equivalent make as directed by EIC. |
| 32 | Providing and fixing of exhaust 200/250mm including terminations as required Crompton/Havells/Orient make |
| 33 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank |
| 34 | Providing and fixing of wardrobe of approved design & make including shutters, partitioning with 19mm thick (water proof) ply board of approved make and quality including back covering of 6mm thick water proof ply and fixing 1mm thick mica of approved colour and make over the frame and shutter, as around including cost of all fixtures i.e. glazing, locking arrangements, handle etc. as per the directions of site Engineer. (complete Job) |
| 35 | Carriage of material by mechanical transport including all loading / unloading complete |
| 36 | Sand Aveg. lead of 20 Km |
| 37 | Stone Aggrigate upto 40mm and above Aveg. lead of 20 Km |
| 38 | Stone Aggrigatebelow 40mm Aveg. lead of 20 Km |
| 39 | Providing and fixing of following types of switches, sockets, allied accessories including dismantling of existing switches and sockets with terminations as required Anchor/Legrand/GM/Crabtree or equivalent make |
| 40 | 16A switch only modular type |
| 41 | 16A socket only modular type |
| 42 | 6A switch only modular type |
| 43 | 6A socket only modular type |
| 44 | Bell push 2 module |
| 45 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in existing surface/ recessed steel/ medium class PVC conduit as required Finolex/Polycab/Anchor/V-Guard/Havells/RR kabel or equivalent make |
| 46 | 2 x 1.5 Sqmm |
| 47 | 2 x 2.5 Sqmm |
| 48 | 2 x 4 sqmm |
| 49 | Providing and fixing of following MCB distribution boxes double door with inbuilt tinned copper heavy duty bus bars for earth, earth, and jumpers of proper current rattings Havells/Anchor/SSK/legrand/hager/indoasian make. |
| 50 | 4 way TPN box |
| 51 | Providing and fixing of following type of MCB's/switch gear of L&T/Havells/Anchor/ Schnedier/indoasian Opti-Pro/Legrand of 10 KA or more capacity series including testing and necessary terminations. |
| 52 | 63A SPN |
| 53 | 6A-32A MCB's |
| 54 | Providing and fixing of LED lights of following type Crompton/Phillips/Orient/Havells/Syska make including necessary terminations as required. |
| 55 | T-5 LED 4' long 20 watt |
| 56 | T5 LED 2' long 9 watt |
| 57 | 12 Watt LED Lamps |
| 58 | Supply and fixing of following sizes moduler base Plate and cover plate including GI box in recess etc as required for moduler swtiches. |
| 59 | 12 Module |
| 60 | 6 Module |
| 61 | 4 Module |
| 62 | 2 Module |
| 63 | Supplying & fixing of two module stepped type fan regulator including necessary terminations as requried |
| 64 | Providing and fixing of 48\\" Sweep ceiling fan with allied accessories complete including necessary terminations crompton/ Havells/Orient/Usha Make. |
| 65 | Supplying and fixing call bell/buzzer suitable for single phase 230V, complete as required |
| 66 | Providing and fixing of Angle/straight holders including terminations GM/Havells/Krant /Anchor/Great white make |
| 67 | Providing and fixing of 25 Litre Geyser including necessary terminations |
| 68 | Providing and laying of 2 core 25 sq.mm aluminium armoured cable along with pin type thimbles and connectors to be laid from source to pannel/mcb box including routing underground in HDPE pipe and to be fixed on walls etc via clamps, saddles etc including terminations as required. |
| 69 | Providing and fixing of Phenolic sheets of desired shapes and sizes incluting cutting, finishing, drilling etc. |
| 70 | Providing and fixing of exhaust 250/300mm including terminations as required Crompton/Havells/Orient make |
| 71 | Providing and fixing of following sizes of PVC battens along the wall or ceiling including dismantling of existing damaged battens. |
| 72 | 1\\" wide surface batten 3 meter long Please Enable Macros to View BoQ information |