Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Civil Works |
| 2 | Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. |
| 3 | 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 4 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 5 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer |
| 6 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats |
| 7 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shadeOld work (one or more coats applied @ 0.83 ltr/10 sqm). |
| 8 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work |
| 9 | Providing and laying double charged Vitrified Floor tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer,in all colours and shade, in floors and skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 1200x 600 mm |
| 10 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 1200x600mm |
| 11 | Providing and laying Matt finish interior Vitrified tiles in floors and skirting with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 1200x600 mm |
| 12 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 1200 mm |
| 13 | Providing and laying glazed Vitrified wall tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer,in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 1200x 600 mm |
| 14 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) |
| 15 | For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 16 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides |
| 17 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm) |
| 18 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm |
| 19 | Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Single rubber stopper |
| 20 | Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in- charge. |
| 21 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. |
| 22 | Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:300x10 mm |
| 23 | X-ray door: Providing and fixing lead-shielded wooden laminated X-ray door of size 1200 × 2100 mm, consisting of 45-50 mm thick solid core flush shutter made from kiln-seasoned BWP grade hardwood, incorporating continuous lead sheet of 1.5 mm Pb equivalence (or as approved by Radiation Safety Officer) sandwiched within the shutter. The shutter shall be finished on both faces with high-pressure decorative laminate of approved shade, provided with hardwood lipping on all edges with concealed lead overlap. The door shall be fixed in factory-fabricated mild steel / GI lead-lined frame of matching lead thickness with necessary lead overlap with wall shielding. The door shall be provided with lead glass vision panel of matching lead equivalence and fitted with stainless steel 304 grade lever handles fixed on approved mortice lock, heavy-duty stainless steel butt hinges, door stopper, EPDM rubber sealing gasket, and all necessary fittings. The work shall include complete installation, alignment, sealing of joints to prevent radiation leakage, fixing of radiation warning signage, complete in all respects as per CPWD DSR, AERB guidelines and directions of Engineer-in-Charge. |
| 24 | Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. |
| 25 | Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer- in-charge. |
| 26 | Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS: 1868) aluminium lever handles of approved quality with necessary screws etc . complete. |
| 27 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:250x10 mm |
| 28 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately) |
| 29 | Providing and fixing 12 mm thick frameless toughened glass partition of approved brand and manufacture, including top & bottom fixing arrangement and making necessary holes etc. for fixing required fittings, all complete as per direction of Engineer-in-charge |
| 30 | Providing and fixing SS H handle having min 45 cm length in toughed glass door including all necessary screws etc. complete. |
| 31 | Providing and fixing of glass door SS Patch Lock with out handle in toughened glass door including all necessary screws etc. complete |
| 32 | Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile size 595x595 mm made of Gypsum plasterboard , manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyster on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyster film so as to make the tile a completely sealed unit. |
| 33 | Providing and fixing composite mezzanine flooring consisting of profiled galvanized steel deck sheet minimum 0.8 mm BMT conforming to IS 277, fixed to steel beams, including shear studs, side trims, closures, 3 mm dia welded wire mesh @ 100x100 mm c/c, complete ready for concreting. Concrete and structural steel measured separately. |
| 34 | Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 35 | Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 36 | Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers |
| 37 | Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform |
| 38 | Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more |
| 39 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 40 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes |
| 41 | Providing & fixing Poly carbonate multi wall plain sheet 8 mm thick as approved by the Engineer in charge and should be supplied in a single length of 12 M or as decide by the Engineer in charge. The sheets shall be fixed using self drilling/ self tapping screw of size ( 5.5x55mm) with EPDM seal complete upto any pitch in horizontal /vertical / curved surface, but excluding the cost of purlins, rafters, trusses, and including cutting to size and shapes where ever required. |
| 42 | Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. |
| 43 | Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar |
| 44 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm |
| 45 | Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge |
| 46 | Renewing glass panes and re fixing existing wooden fillets: Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) |
| 47 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in- charge. |
| 48 | Taking out doors, windows and clerestory window shutters and glazing (Aluminium Work) including stacking within 50 metres lead: Of area beyond 3 sq. metres |
| 49 | Taking out doors, windows and clerestory window shutters (steel or wood ) including stacking within 50 metres lead:Of area 3 sq. metres and below |
| 50 | Providing and fixing factory made uPVC white colour fixed glazed windows/ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.) |
| 51 | Providing and fixing factory made uPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 +/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with top fixed with S.S. friction hinges (350 x 19 x 1.9 mm) made of (small series) frame 47 x 50 mm, sash 47 x 68 mm & mullion 47 x 68 mm all having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. ( Area of window upto 2.50 sqm). |
| 52 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 53 | Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge |
| 54 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 55 | Hospital Cubicle Curtain Work: Providing, stitching, and fixing stain-retardant and fire-retardant hospital cubicle curtains suitable for X-ray room, ultrasound room, screening area, and general patient privacy partitions, made from approved quality polyester/antimicrobial fabric of minimum 180-200 GSM, washable and colour-fast, with mesh/net panel not less than 300 mm at the top for ventilation and fire safety compliance, and overall finished curtain height not less than 2.10 m, including full- length pleating (minimum 1.5 times fullness), reinforced heading tape, stainless steel or nylon hooks/rollers, and proper hemming at bottom. The work shall include supply of cloth (minimum rate Rs. 300 per metre or above), stitching, finishing, and fixing to existing or new ceiling-mounted aluminium curtain track/rod, complete in all respects as directed by the Engineer-in-Charge.Rate shall be measured and paid per running metre (Rmt) of curtain track/rod length, inclusive of fabric quantity, stitching, accessories, labour, wastage, and all incidental charges, but excluding the cost of curtain track/rod if supplied separately, complete. |
| 56 | Plumbing work |
| 57 | Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. |
| 58 | Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. |
| 59 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required:Single half stall urinal with 5 litre PVC. automatic flushing cistern |
| 60 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in Charge and finished smooth.Granite Stone of approved shade |
| 61 | Providing and fixing white vitreous china counter top wash basin of minimum size 485 × 310 × 130 mm, conforming to relevant IS standards, including fixing on C.I. brackets painted with two coats of synthetic enamel paint over a coat of primer, complete with 15 mm dia C.P. brass long/extended pillar taps, 32 mm dia C.P. brass waste of standard pattern, including all necessary fittings, fixtures, supports, cutting and making good the walls wherever required, and connection to inlet and outlet pipes, complete as directed by Engineer-in-Charge. |
| 62 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Angle back wash basin size 400x400 mm with single 15 mm C.P. brass pillar tap |
| 63 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Angle back wash basin size 600x480 mm with single 15 mm C.P. brass pillar tap |
| 64 | Providing and fixing uplasticised PVC connection pipe with brass unions: 45 cm length15 mm nominal bore |
| 65 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore |
| 66 | Supplying and fixing CP Towel rod 45cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in- charge. |
| 67 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete Flexible pipe32 mm dia |
| 68 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore |
| 69 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge Concealed work, including cutting chases and making good the wall etc. 15 mm pipe 10kgf/cm2 |
| 70 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work,including cutting chased and making good the wall etc. 20 mm pipe 12 Kgf/cm2 |
| 71 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 25 mm pipe 12 kgf/cm2 |
| 72 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 10Kgf/cm2 |
| 73 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 10 kgf/cm2 |
| 74 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10 Kgf/cm2 - External work- Exposed on wall |
| 75 | Providing and fixing PVC pipes including all fittings like bent,tee,elbow,collar etc complete for jointing pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall |
| 76 | Providing and fixing PVC pipes including all fittings like bent, tee,elbow,collar etc complete for jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 |
| 77 | Providing and fixing PVC pipes including all fitting like bent,tee,elbow, collar etc fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall |
| 78 | Providing and fixing PVC pipes, fittings including all fitting like bent, tee,elbow,collar etc fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall |
| 79 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl |
| 80 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Socket /coupling |
| 81 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow |
| 82 | Providing and fixing beveled edge mirror of superior glass (of approved quality) of maximum height 1500mm complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 83 | Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia End Cap |
| 84 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement-110 mm dia Door Elbow |
| 85 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend |
| 86 | Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl |
| 87 | Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x75 mm dia Reducer |
| 88 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore |
| 89 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore |
| 90 | Supplying and fixing C.I with out frame for manholes:560 mm diameter ( heavy duty) the weight of the cover to be not less than 108 kg |
| 91 | Providing and fixing SS grating of approved quality and colour. Rectangular type with openable lid150 mm nominal size square 100 mm diameter of the inner hinged grating. |
| 92 | Supplying and fixing PVC Floor Trap 100mmx75mm size without Jali including cutting open, boring through RCC slabs and making good the damages. |
| 93 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 94 | Providing and fixing PVC pipes including all fittings like bent, tee, elbow, collar etc complete for jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.75 mm dia. 6Kgf/cm2 |
| 95 | Furniture |
| 96 | Providing reception counter of required size (Minimum width 600 mm and seating height of 750 mm and total height of 1050 ) made up of 18 mm thick pre-laminated medium density fibre board exterior grade (Grade-I) IS: 14587:1998 marked with laminated finish on both sides with cable management tray, grommet, required 3 Nos sockets and Ethernet port, three drawer pedestal unit with channels handles, hinges, lock all complete as per approved design of Engineer in charge/Architect. Elevation area to be measured. |
| 97 | L-Type workstation of overall size (1350 x 600)mm + (900 x 450)mm x 750 mm (Lx D x H) and pedestal unit made up of 18 mm thick Exterior Grade-I MDF board on all sides conforming to IS:14587 from approved makes such as Century/Greenply/Fineply or equivalent with decorative laminate on both side and all edges to be fixed with 2mm thick pvc edge beading. One three-drawer modular pedestal unit of minimum size 450 mm (W) x500 mm (D) x 650 mm (H) all with retractable key board tray, drawer channels, hinges, handles, individual locking system, and all necessary fittings and the workstation should have an electrical flip box with 2 nos universal power socket & 1 no data socket etc and cable management tray. All work as per the approved design and instruction of the Engineer-in-Charge/Architect. |
| 98 | L type Consultation Table ((1100-1200 x600)+(800x450)) x 750 mm, all frames made with powder coated MS steel tubes of size 40x40x2mm with level adjusting screws.Table Top using 25mm thick MDF with 1 mm thick lamination of selected colour and back side 0.8mm thick white or off-white lamination finish. 8 Module Flip Boxes with Supply Box having min 3 nos universal type power 6A socket controlled by One switch, 2 data points one for network and other for IP PBX on table top including divided power and control cable & wire ways from end to end should be provided. Front and sides vertical cover panel with powder coated perforated steel sheet of thick 1.5mm in all vertical leg supports. |
| 99 | Linear workstation of overall size minium1100-1200 mm x 600mm x 750 mm (L x D x H) and pedestal unit made up of 18 mm thick Exterior Grade-I MDF board on all sides conforming to IS:14587 from approved makes such as Century/Greenply/Fineply or equivalent with decorative laminate on both side and all edges to be fixed with 2mm thick pvc edge beading. One three-drawer modular pedestal unit of minimum size 450 mm (W) x 500 mm (D) x 650 mm (H) all with retractable key board tray, drawer channels, hinges, handles, individual locking system, and all necessary fittings and the workstation should have an electrical flip box with 2 nos universal power socket & 1 no data socket etc and cable management tray. All work as per the approved design and instruction of the Engineer-in-Charge/Architect. |
| 100 | Linear workstation of overall size 1200mm x 600mm x 750 mm (L x D x H) and pedestal unit made up of 18 mm thick Exterior Grade-I MDF board on all sides conforming to IS:14587 from approved makes such as Century/Greenply/Fineply or equivalent with decorative laminate on both side and all edges to be fixed with 2mm thick pvc edge beading. One three-drawer modular pedestal unit of minimum size 450 mm (W) x500 mm (D) x 650 mm (H) all with retractable key board tray, drawer channels, hinges, handles, individual locking system, and all necessary fittings and the workstation should have an electrical flip box with 2 nos universal power socket & 1 no data socket etc and cable management tray. All work as per the approved design and instruction of the Engineer-in-Charge/Architect. |
| 101 | Linear workstation of overall size 1500mm x 600mm x 750 mm (L x D x H) and pedestal unit made up of 18 mm thick Exterior Grade-I MDF board on all sides conforming to IS:14587 from approved makes such as Century/Greenply/Fineply or equivalent with decorative laminate on both side and all edges to be fixed with 2mm thick pvc edge beading. One three-drawer modular pedestal unit of minimum size 450 mm (W) x 500 mm (D) x 650 mm (H) all with retractable key board tray, drawer channels, hinges, handles, individual locking system, and all necessary fittings and the workstation should have an electrical flip box with 2 nos universal power socket & 1 no data socket etc and cable management tray. All work as per the approved design and instruction of the Engineer-in-Charge/Architect. |
| 102 | Lab work bench -The work bench top made up of 18mm thick granite top edge moulded over 18 mm thick marine plywood and GI Powder coated frame work of section size not less than 50x50x1.5mm. The width of the table shall be 750mm and height shall be 850mm. The frame provided with level adjusting screws fixing accessories ,carriage of material all complete as per the approved drawings and direction of Engineer in charge.Note Only length of the table shall be measured for making payment. |
| 103 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm,with swan neck faucet with pipe in let and drain provision, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink with drain board510x1040 mm bowl depth 250 mm |
| 104 | Providing and fixing a dining table of overall size 1000 × 800 × 750 mm with an 18 mm thick engineered quartz stone top of approved make, shade and finish, suitable for dining use, having polished or matt polished surface with machine-cut edges and 3?5 mm chamfer or pencil round. The quartz top shall be mounted on a mild steel sub-frame made of 40 × 20 × 2 mm RHS sections, firmly fixed using approved adhesive and concealed fasteners. The dining table shall be supported on mild steel square tube legs of size 50 × 50 mm and minimum 2 mm thickness, properly welded, ground smooth and finished with powder coating of minimum 60?80 microns thickness in approved colour. Adjustable PVC/nylon levellers shall be provided at the bottom of the legs. The dining table shall be complete in all respects including materials, fabrication, powder coating, fixing and installation at site, and shall be measured per number (each), with the rate inclusive of all labour, tools, transportation and incidental charges. |
| 105 | Providing and fixing dining chair with back rest and without arm suitable for use with dining tables, having a mild steel tubular frame fabricated from 25 × 25 × 1.6 mm square hollow sections, properly welded, ground smooth and finished with powder coating of minimum 60?80 microns thickness in approved colour. The seat and backrest shall be of moulded polypropylene (PP) / ergonomically shaped plywood with laminate finish, firmly fixed to the frame using concealed fasteners. The chair shall have a seat height of approximately 450 mm, with non-slip PVC/nylon end caps provided at the bottom of legs to protect flooring. The chair shall be complete in all respects including materials, fabrication, powder coating, fixing and installation at site, and shall be measured per number (each). |
| 106 | Revolving Chair: Medium back ergonomic chair with five nos. star shaped Nylon base. Castor: 50mm diameter nylon twin wheel, gas lift height adjustment, back angle adjustment , Fixed armrest providing natural resting for arms. Seat with PU coated foam backed fabric, back rest with mesh type fabric, upholstery: Heavy duty rubber backed fabric in BLACK |
| 107 | Office Chair: Non-revolving executive chair with fixed armrest providing natural resting for arms. Seat with PU cutted foam backed fabric, back rest with mesh type fabric, Upholstery: Heavy duty rubber backed fabric in BLACK ( Size -55x60 cm) |
| 108 | Supply of phlebotomy chair with optimum design made up of MS Power coated frame and up upholstery type seat,back rest and arm rests.Both side arm rest should be with height and position adjustable system and all as per the instruction of Engineer in charge. |
| 109 | Counter Height Stools : Supply and erection of counter height stools ( bar stools ) of following specifications :Revolving adjustable Chrome plated steel body chairs with resistance to the corrosion. Cushion Seat with Lift mechanism for Adjustment of height. Minimum height 750mm before expansion. Medium Back rest and arm rest. Item shall be of reputed make. |
| 110 | MS Powder-Coated Cushioned Airport Type Three-Seater Waiting Chair: Providing and supplying airport type three-seater waiting chair having main frame made of heavy duty mild steel (MS) tubular/rectangular section with central beam support, finished with epoxy powder coating of approved shade and thickness not less than 60 microns. Each seat shall be ergonomically designed with cushioned seat and back made of high-density PU foam upholstered with superior quality rexine/fabric, fixed securely to the frame. The chair shall be provided with MS armrests between seats, sturdy MS legs fitted with PVC/nylon bushes for floor protection, suitable for heavy- duty use in hospital waiting areas. The overall size shall not be less than 1500 mm length with minimum 450 mm seat depth and 430-450 mm seat height. The item shall include all materials, labour, fittings, transport, handling and placing at site complete as per the direction of the Engineer-in-Charge. |
| 111 | Cabinet/Wardrobe: Providing and fixing Cabinet/Wardrobe unit with 18 mm thick Multi wood board with one side decorative and other side balancing lamination. cupboard shutters edge to be sealed with PVC edge bending tape 2.00 mm thick of approved brand including ISI marked nickel plated bright finishing M.S. piano hinges conforming to IS:3818 marked with fixing chromium plated brass 50 mm cupboard or wardrobe knobs, special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. Depth of shelves to be 300-600mm and shelves to be fix with proper support and bracket holders. as per layout drawing approved by Engineer in charge. Make laminate: Greenlam/ Merino / Century. Only front elevation will be measured. |
| 112 | Slotted Angle Racks : Supply and errection of Powder coated slotted angle metalic rack having min 8 shelfs made up of min 40 X 40 X 2 mm size rolled steel angle posts shall have 8-mm diameter holes provided at 50-mm centre to centre. Metal shelves shall be made from mild steel sheets not less than 1.0 mm in thickness and with sufficient stiffners. Shelves shall have lipped flanges width of flange being 30 mm and depth of lip 15 mm .Min size of rack 900mm Length X 300mm Depth X 2000mm Height. |
| 113 | Providing, supplying and placing general hospital examination bed made of strong MS tubular frame, duly pre-treated and epoxy powder coated, with a three-section top cushioned with high-density foam and covered with washable, anti-bacterial, fire- retardant synthetic upholstery of approved colour. The table shall have an adjustable backrest and leg section operated manually, provision for paper roll holder, and rubber shoes at the bottom to prevent floor damage. Overall size shall be approximately 1800 mm × 600 mm × 750 mm height, suitable for routine medical examination in hospitals and clinics. The item shall also include an additional step-up stool made of stainless steel (SS 304) with non-slip rubber top surface, sturdy welded construction, and anti-skid rubber legs, suitable for patient access to the examination table. The rate shall include all fittings, accessories, handling, placement, and making good, complete in all respects as per directions of the Engineer-in-Charge. |
| 114 | Providing, supplying and placing a USG (Ultrasound) examination bed made of a strong MS tubular frame, duly pre-treated and epoxy powder coated, suitable for routine ultrasound examinations in hospitals. The bed shall have a fixed or adjustable cushioned top with high-density foam covered in washable, anti-bacterial, waterproof upholstery of approved colour. The bed shall be provided with a headrest section adjustable manually, smooth rounded edges, and anti-skid rubber shoes at the bottom to prevent floor damage. The minimum size of the bed shall be 1800 mm (L) × 600 mm (W) × 750 mm (H). The item shall be complete with all fittings, accessories, handling and placement, trasportation all complete as directed by the Engineer-in-Charge. |
| 115 | Providing, supplying, and fixing semi-blackout / light-filtering roller blinds of approved make and shade, suitable for terrace windows exposed to direct sunlight. The blinds shall be made of polyester / PVC coated fabric with 60–80% light filtering capacity, UV resistant and fade-proof, with a thickness of 0.35–0.55 mm and weight of 300–500 GSM. The roller mechanism shall consist of a heavy-duty aluminium roller tube, chain-operated or spring-loaded system, complete with powder-coated brackets, end caps, and an aluminium bottom bar for proper tension. The work shall include dismantling and removal of existing curtains/blinds including all hardware, cleaning and preparing the window surface, and fixing the new blinds in perfect alignment using stainless steel screws and nylon plugs. The blinds shall be installed strictly as per manufacturer’s instructions, ensuring smooth operation and neat finish, with measurement taken per square metre. |
| 116 | Signage |
| 117 | Providing and fixing 3M Fasara frosted etching film of thickness 25 microns self- adhesive of approved colour, shade, and quality with cutting as per approved design and pattern, including cleaning of glass and making surface smooth for fixing of film to the surface, all completed as per the direction of the engineer in charge. |
| 118 | Providing and fixing in position the signage board made out of 3 mm opaque PVC foam board of computerised cut, PVC non reflective self adhesive vinyl painted foam board of required size and colour. |
| 119 | Backlit Acrilic Board with projected letters: Supply, installation, testing and commissioning of weatherproof backlit acrilic board with projected letters made upof 20mm thick acrilic board and having box depth of min 100mm in approved size and design with reqired LED strips for high glow light. The board shall be fabricated and fixed over suitable welded and painted 25X25X3mm MS angle frame in suitable location and in proper line and level with all necessary fastners, supports etc. Electrical works likes electrical wirings, connections, fittings, externaly fixed weather proof 2/3 pin plug points and sockets including boxes etc. to be complete properly. All fabrication and fixing should be done as per approved design and instructions of Engineer in Charge. (Note: Only front elevation will be measured.) |
| 120 | Vinyl Transparent Vision Glass Stickers: Supply and pasting of Vinyl Transparent Vision Glass Stickers in approved size and design in glass partition and door as per the instruction of Engineer in Charge. |
| 121 | Supplying, fabricating and fixing flex board signage of approved design and size, using high-quality flex media with opaque (black) back, suitable for indoor/outdoor application, including digital printing with minimum 8-pass solvent/eco-solvent printing to ensure colour uniformity and clarity, complete as directed by the Engineer- in-Charge. The flex shall be stretched and fixed on a rigid framework fabricated from G.I. square tubes of minimum size 25 mm × 25 mm (1 inch × 1 inch) of suitable thickness, properly welded, cleaned and treated with one coat of red oxide/zinc chromate primer and two coats of approved synthetic enamel paint. The board shall be securely fixed to wall or structure with required clamps, bolts, nuts, screws, anchors, drilling and finishing, complete in all respects. Measurement shall be in square metre of exposed flex area. |
| 122 | Providing and fixing non-illuminated foam board signage of approved design, size and colour, made from high-density PVC foam board (Sunboard or equivalent) of minimum 5 mm thickness, suitable for indoor application, finished with high-quality digital printed vinyl / self-adhesive vinyl (minimum 720 dpi, 6–8 pass printing) as per approved artwork, including surface preparation, pasting, trimming and neat edge finishing. The foam board shall be fixed to wall, partition or ceiling using approved adhesive, double-sided tape, screws with caps or spacers, including all necessary fittings, hardware, labour, scaffolding and incidentals, complete as directed by the Engineer-in-Charge. Measurement shall be in square metre of finished exposed area. |
| 123 | POINT WIRING |
| 124 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B |
| 125 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C |
| 126 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C |
| 127 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 128 | CIRCUIT WIRING |
| 129 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire |
| 130 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 131 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 132 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 133 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 6 Sq.mm + 1 x 6 sq.mm earth wire |
| 134 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 135 | SWITCH AND SOCKET |
| 136 | Supplying and fixing following modular switch/ socket on the existing modular plate &switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 137 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 138 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 139 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 140 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 141 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) |
| 142 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 143 | Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A SP switch with indicator |
| 144 | Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket |
| 145 | Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 146 | Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 147 | Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43) |
| 148 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)16 way, Double door |
| 149 | Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL |
| 150 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 151 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps |
| 152 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 153 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 154 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps |
| 155 | Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
| 156 | Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole |
| 157 | Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 158 | Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole |
| 159 | Supply and fixing of 2 Pole enclosure for fixing 2P MCB in wall, including accessories |
| 160 | Supply and fixing of 4 Pole enclosure for fixing 4P MCB in wall, including accessories |
| 161 | PANELS |
| 162 | SITC Of LT Distribution Panel shall be a CPRI-approved, floor-mounted, indoor, compartmentalized, dust and vermin-proof panel fabricated from CRCA sheet steel with IP54 protection and epoxy powder coating, rated for 433V, 50Hz, 3-phase, 4- wire system. The panel shall have an incomer comprising 1 No. 125A TP+N MCCB (25kA, thermal magnetic), RYB LED indication lamps with 2A fuses, 1 No. 0-400A digital ammeter with selector switch and CTs, 1 No. 0-500V digital voltmeter with selector switch, and 1 No. multifunction digital meter measuring V, A, kW, kVA, PF, and frequency. The outgoing section shall consist of 1 No. 100A TP+N MCCB (25kA), 4 Nos. 63A TP+N MCCBs (25kA), and a separate multifunction digital meter with LED ON/OFF/TRIP indicators and 2A fuses for feeder status. The panel shall be provided with a 150A rated TPN extensible aluminum busbar system with 25kA fault withstand capacity, supported on SMC supports and insulated with heat-shrinkable sleeves, internal wiring using FRLS copper conductors, appropriate interlocking between feeders, double earthing using 25x3 mm Cu strips, and mounting on MS channel base. All components shall be IS/IEC certified, and the panel shall be tested at CPRI for short circuit, temperature rise, and IP protection as per IS 8623/IEC 61439 standards. |
| 163 | SERVICE CUBICLE: Fabrication, supply, erection, testing and commissioning of Outdoor type CT metering panel cubicle type, dust and vermin proof, wall mounted, front operated, MV panel board made out of 16 SWG thick CRCA sheet fully compartmentalized complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all omponents. It consist of 125A, 25kA, 433V, FP MCCB - 1No RYB phase indicating LED lamps with control fuses and switches -1No,125A HRC fuse 3nos and provision for 150/5A, CL:0.2S, 15VA cast resin CT, provision for kWh meter after testing at Electricity Board TMR Division. All opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant. |
| 164 | Providing liaisoning services for obtaining power allocation, service connection, approvals, sanctions, testing and energisation from Kerala State Electricity Board (KSEB), obtaining inspection, testing approval and energisation sanction from Electrical Inspectorate, Government of Kerala, and coordination with all other statutory/local authorities concerned with electrical installations, including submission of applications, drawings, test reports and documents, attending inspections, arranging site visits, remitting statutory fees (statutory fees shall be paid separately), complying with observations, follow-up till issue of approvals/energisation order, and handing over all relevant certificates and documents complete, as required and as directed by the Engineer-in-Charge.( All statuary payments may be reimbursable on the submission of orginal receipt) |
| 165 | CABLES |
| 166 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 120 sq mm |
| 167 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 95 sq mm |
| 168 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp |
| 169 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp |
| 170 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp |
| 171 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp |
| 172 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp |
| 173 | Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp |
| 174 | CABLE TERMINATION |
| 175 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm) |
| 176 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm) |
| 177 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 120 sq. mm (45mm) |
| 178 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm) |
| 179 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) |
| 180 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) |
| 181 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm) |
| 182 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) |
| 183 | CABLE TRAY |
| 184 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X50 mm depth X 2.0 mm thickness |
| 185 | Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.450 mm width X 50 mm depth X 2.0 mm thickness |
| 186 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 450 mm width X 50 mm depth X 2.0 mm thickness |
| 187 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness |
| 188 | Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.300 mm width X 50 mm depth X 1.6 mm thickness |
| 189 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness |
| 190 | Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness |
| 191 | EARTHING PROTECTION |
| 192 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 193 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.(but without charcoal/ coke and salt) as required |
| 194 | Supplying and laying 25 mm X 3 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) including excavation and refilling |
| 195 | Providing and fixing 25 mm X 3 mm copper strip on surface/Cable tray or in recess for connections etc. as required. Rate to include cost of suitable GI clamps SS hardware, making welded joints etc all complete with. No holes shall be drilled to the conductor for clamping purpose |
| 196 | Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG) |
| 197 | Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 198 | Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) |
| 199 | LIGHT AND FAN FIXTURES |
| 200 | Supply, Installation of surface mounted 4Feet LED Tubelight. The luminaire should have CRI 80 and CCT of both 6500K/5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and efficacy of at least 105 lumen/watt and Minimum system wattage of 24 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 25k burning hours. The electronic driver used shall have a power factor 0.95 and THD. Make - Philips, Crompton, Wipro, Havells |
| 201 | Supply, conveyance and Installation of compact, 2 feet,10-15W,LED tube light with high lumen giving soft glare free light including all required mounting accessories, frames complete. (Philips/WIPRO/Havells or equivalent) |
| 202 | Supply and Installation of surface/recess mounted LED 2x2 luminaire with CRCA housing suitable with fully diffused diffuser for general lighting. The luminaire should have CRI 80 and CCT of both 6500K/5700K, Cool White Light. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3700 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 36 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours. The electronic driver used shall have a power factor 0.95 and THD. Make-Philips, Crompton, Wipro or equivalent |
| 203 | SITC of commercial integrated round type surface LED down light fitting having color temperature having not less than 5700K, system lumen output not less than 1800 and system wattage not less than 18 W, CRI not less than 80, high transmittance diffuser, inbuilt electronic driver with surge protection not less than 2kV etc as required. |
| 204 | Supply, installation, testing and commissioning of 1200 mm sweep BEE-5 star rated ceiling fan with brushless direct current motor (BLDC) , class of insulation B , 3 no:s blades , 30 cm long down rod , 2no:s canopies, shackle kit, safety rope , copper winding, power factor not less than .9, service value (CM/M/W) minimum 6.00, Air delivery minimum 210 cum/min,350 RPM (tolerance as per IS :374-2019, THD less than 10% remote or electronic regulator unit for speed control and all remaining accesories including safety pin, nut and bolts , washers, temperature rise equal to 75 deg celsius ( maximum) , insulation resistance more than 2 Megaohm , suitable for 230V,50 Hz, single phase AC supply , earthing etc., complete as required: |
| 205 | TELEPHONE |
| 206 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair |
| 207 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 208 | Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.Telephone socket outlet |
| 209 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 210 | Supply, installation, testing, and commissioning of Telephone Krone Type Disconnection Box with 10-pair or 20-pair capacity (expandable), suitable for structured voice cabling distribution. The box shall include high-quality LSA-PLUS (Krone type) modules, a weather-resistant enclosure, and accessories. |
| 211 | Supply, laying and termination of 10 pair telephone cable, 0.5mm copper PVC insulated, unarmoured telephone cable drawn in the existing cable tray |
| 212 | NETWORKING AND CCTV |
| 213 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 214 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 215 | Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable |
| 216 | Supplying and fixing RJ45 Outlet including cover plate, Keystone Jack and Gang box supporting, connection etc. as required |
| 217 | Supply, installation, testing, and commissioning of 24-Port, 1U, Cat6A fully loaded shielded patch panel, suitable for high-speed structured cabling systems in data and networks. Make - Molex / Legrand / D-Link/ equivalent |
| 218 | Supply, installation, testing, and commissioning of 12-Port, 1U, Cat6A fully loaded shielded patch panel, suitable for high-speed structured cabling systems in data and networks. Make - Molex / Legrand / D-Link/ equivalent |
| 219 | Supply, installation, testing & commissioning of 8 port L2 Ethernet switch |
| 220 | Supply, installation, testing & commissioning of 24 port L2 Ethernet switch |
| 221 | Supply, installation, testing and commissioning of 10 100/1000 SFP ports + 4 Combo 10/100/1000 Copper ports + 4 10G SFP+ ports, - Core Switch |
| 222 | Supply and installation of 9U rack with Front glass door, Rear Perforated door with handle Lock &key. Front/Rear 19" mounting angles, top, bottom open, RAL 9005 with all other accessories |
| 223 | Supply and installation of Cat 6 UTP patch cord, 1 mtr |
| 224 | Supply and fixing of 4U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete. |
| 225 | Supply, Installation, Testing and Commissioning of 2MP IR Network dome Camera for 30mtr length including accessories. |
| 226 | Supply of 2TB internal hard disk for use in Network Video Recorder (NVR) systems for CCTV/video surveillance. The hard disk shall be of surveillance-grade, specifically designed for 24×7 continuous operation and capable of handling multi- camera recording without data loss. The drive shall be of 3.5 SATA form factor with SATA III (6Gb/s) interface and optimized firmware for sequential write operations, vibration tolerance, low power consumption, and error recovery suitable for NVR workloads. The hard disk shall have a workload rating appropriate for continuous surveillance applications and be compatible with the specified NVR model. The supply shall include all necessary mounting accessories, cables, and connectors required for proper installation. |
| 227 | Supply, installation, testing and commissioning of 24 10/100/1000BASE-T ports + 2 10GBASE-T ports + 4 10G SFP+ ports, L3 Stackable Managed Switch - Core Switch |
| 228 | Supply, installation, testing and commissioning of 8-Ports 10/100/1000Mbps PoE + 2-Ports SFP 100/1000Mbp Managed Switch, 60 Watts, 8 port- Edge PoE switch |
| 229 | Supply, installation, testing and commissioning of Server PC, Intel i7 processor, 24 inch LED monitor, Gigabit LAN port, USB port, 8GB DDR3 RAM,1TB HDD,1GB dual graphic card, 100/1000 LAN ports, optical mouse, Keyboard, DVD Writer.Genuine Win 8.1 Pro - Down grade to Win 7 professional, 24 inch LED monitor |
| 230 | Supply of External Hard Disk of 5TB. |
| 231 | Supply and Installation of LED Color Monitor of minimum 32 inch screen, complete, UHD display Make: LG/Samsung/Panasonic or equivalent. |
| 232 | Supply, Installation, Testing and Commissioning of Wifi Access Point with superior 802.11ac performance (up to 1.2Gbps) 2 x 2 (Transmit x Receive) with 2 streams of data for 2.4 GHz (300 Mbps) and 5 GHz (1750 Mbps) of reliable data delivery 802.11ac beamforming to improve range, minimizes interference while maximizing data rates Internal antennas for maximum RF performance. including Wall / Ceiling Mount Kit for fixing access points With required licenses & OEM technical support / warranty along with required accessories |
| 233 | SITC of Inverter Air Conditioner: Supply, installation, testing and commissioning of Air Cooled 4 way Cassette Type Air Conditioner of following capacity consisting of cordless remote control and one number outdoor condensing unit comprising of energy efficient suitable rotary/twin rotary compressor for operation on single phase, 230 V, 50Hz supply, fixing the outdoor unit on a raised platform as per manufacturers recommendation and fixing of room unit on Ceiling, standard 3 m distance refrigerant copper piping with 13mm nitrile rubber insulation, providing and making interconnection between room & condenser as per site conditions, comprising of 1" dia drain PVC pipe with insulation 3m, canvas connections, full electrical/communication cabling from power plug near indoor unit and to outdoor unit, ODU MS stand, first charge refrigerant gas complete as required. (Make : Voltas, Carrier, Blue Star, Hitachi, LG ) : 2 TR 3 star rated as per BEE |
| 234 | Supply, installation, testing and commissioning of Split Air Conditioner of following capacity and specifications: Consisting of high wall-mounted type room unit with cordless remote control and one number outdoor condensing unit comprising of energy-efficient suitable rotary compressor for operation on single-phase, 230 V, 50Hz supply, fixing the outdoor unit on a raised platform as per manufacturers recommendation and fixing of room (fan coil) unit on wall, standard 3 m distance refrigerant copper piping with 13mm nitrile rubber insulation, providing and making interconnection between room & condenser as per site conditions, comprising of 1\\" dia drain PVC pipe with insulation up to 3 m, canvas connections, full electrical cabling from power plug near indoor unit and to outdoor unit, ODU MS stand, first charge refrigerant gas, suitable stabilizer etc complete as required. (Make: Voltas, Blue Star, Hitachi, Carrier or equivalent). 2 TR 3 Star rated (inverter type AC) as per BEE |
| 235 | Supply, installation, testing and commissioning of Split Air Conditioner of following capacity and specifications: Consisting of high wall-mounted type room unit with cordless remote control and one number outdoor condensing unit comprising of energy-efficient suitable rotary compressor for operation on single-phase, 230 V, 50Hz supply, fixing the outdoor unit on a raised platform as per manufacturers recommendation and fixing of room (fan coil) unit on wall, standard 3 m distance refrigerant copper piping with 13mm nitrile rubber insulation, providing and making interconnection between room & condenser as per site conditions, comprising of 1\\" dia drain PVC pipe with insulation up to 3 m, canvas connections, full electrical cabling from power plug near indoor unit and to outdoor unit, ODU MS stand, first charge refrigerant gas, suitable stabilizer etc complete as required. (Make: Voltas, Blue Star, Hitachi, Carrier or equivalent). 1 TR 3 Star rated (inverter type AC) as per BEE |
| 236 | Supply, installation, testing and commissioning of Split Air Conditioner of following capacity and specifications: Consisting of high wall-mounted type room unit (fan coil) with cordless remote control and one number outdoor condensing unit comprising of energy-efficient suitable rotary compressor for operation on single- phase, 230 V, 50Hz supply, fixing the outdoor unit on a raised platform as per manufacturers recommendation and fixing of room (fan coil) unit on wall, standard 4 m distance refrigerant copper piping with 13mm nitrile rubber insulation, providing and making interconnection between room & condenser as per site conditions, comprising of 1\\" dia drain PVC pipe with insulation up to 4 m, canvas connections, full electrical cabling from power plug near indoor unit and to outdoor unit, ODU MS stand, first charge refrigerant gas, suitable stabilizer etc complete as required. (Make: Voltas, Blue Star, Hitachi, Carrier or equivalent). 1.5 TR 3 Star rated (inverter type AC) as per BEE |
| 237 | Additional refrigerant Copper piping Kit for Split ACs : Supplying and installation of additional refrigerant piping kit consisting of power and control cables, good quality copper tubing, Elastomeric Nitrile rubber insulation etc. for Split AC units. |
| 238 | Drain Piping for Split ACs: Supply & installation of PVC insulated piping for condensate drain Including wall chasing, necessary supports, Clamps etc complete as required |
| 239 | DISMANTLING |
| 240 | Dismantling of existing internal electrical installations including point wiring, circuit wiring, sub-main wiring, power wiring, control wiring, PVC/metal conduits, casing and capping, batten wiring, switch boxes (flush/surface), modular/non-modular switches, socket outlets, fan regulators, ceiling roses, junction boxes, light fittings, fans, call bells, exhaust fans, MCB/isolator, SPN/TPN distribution boards with incoming and outgoing connections, earthing connections and all other associated accessories complete, after proper isolation of supply, carefully removing and stacking serviceable materials as directed and making good damages to the existing building surface, as required. |
| 241 | Supply installation, testing and commissioning of following Three Phase Input to Three phase output UPS with battery backup, indoor (IP20) with surge protection system in stand alone configuration, true online double conversion DSP based UPS system, with min 30 min backup battery with, input pf 0.9, less input current consumption, IGBT rectifier and IGBT inverter. It shall be 100% generator compatible with efficiency 90% and output power factor 0.8 and including all accessories etc as required. The UPS system shall be with manual maintenance bypass switch facility. The system shall comply to IEC /EN 62040-1 and relevant IS standard and. The acoustic noise of the system should be less than 58dB. The system shall comply to IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3 and relevant IS standard. 10kVA Double conversion online UPS - 1 Nos, Battery Circuit Breaker-1 nos, Battery Required nos. of SMF for providing 30 Minutes Backup and Battery |
| 242 | 82.5KVA DG SET WITH AMF PANEL - Providing, Installing, Testing and Commissioning of silent Type Diesel Generating set of CPCB 4 compliant along with having prime Power Rating of 82.5 KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system for 0.85 Load Factor and consisting of Diesel engine, 4 stroke water cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at 40 Degree C, 50% RH at 1000 Meter MSL and conforming to BS 5514, BS 649, IS 10000, capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the required accessories and Synchronous alternator rated at 82.5 KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 Degree C, 50% RH at 1000 Meter MSL. The alternator shall be having SPDP enclosure, brushless, continuous duty, self-excited and self-regulated through AVR conforming to IS: 4722/BS 2613 suitable for tropical conditions and with class- F/H insulation, Including CPWD/EI/EB approved AMF panel, Base Frame, Fuel Tank, Battery with leads and other accessories with type competent approved Canopy as a complete set. Contractor has to arrange load test at site or at factory without any additional cost or claim. Including First fill of lube oil and Engine safeties; LLOP, HWT, Initial filling of diesel for standard testing procedure up to 6 hours minimum and 12 hours maximum. Also ensuring noise level not exceeding 75 dB(A) at 1 metre distance under free field conditions, as per CPCB norms. |
| 243 | Supply, erection, commissioning of additional length of exhaust pipes with long radius bend from residential silencer with necessary clamps, fixtures, civil works and painted with heat resistant, rust proof, bituminous paint of approved colors to a maximum of 10 m in stages of following sizes including suitable rain cap for top to avoid rain water entry. The distance between exhaust pipe at top and rain cap should be higher than diameter of pipe. It is also recommended that horizontal run of exhaust piping should slope downwards away from engine to the condensate trap. Silencer should be installed with drain plug at bottom. Fixing shall be done with proper clamps, expansion bolts, and all other accessories as instructed by the Engineer and the rate inclusive of all minor civil works required, bolts, clamps etc as required for installation. Support to exhaust piping should be done in such a manner that load of exhaust piping is not exerted to turbocharger. Exhaust pipe height shall be 3m more than the top of any adjacent building within 10m radius of the exhaust. 300 mm dia |
| 244 | Providing and fixing thermal insulation to Diesel Generator exhaust piping including silencer, with resin bonded glass wool insulation of required density (minimum 48 kg/m³) and required thickness (minimum 50 mm or as specified), conforming to relevant IS standards, securely wrapped over exhaust pipe and silencer surface, tied with G.I. binding wire and chicken mesh where required, and finished with 22 SWG aluminium sheet cladding, properly fabricated, wrapped and fixed with necessary overlaps (minimum 50 mm), joints sealed, secured with aluminium/G.I. self-tapping screws/rivets and circumferential bands at suitable intervals, including provision of bends, flanges, valves and other fittings, complete as required and as directed by Engineer-in-Charge. |
| 245 | Fire Alarm System |
| 246 | INTELLIGENT FIRE ALARM SYSTEM Supplying, installation, testing & commissioning of addressable fire control module complete as required. |
| 247 | INTELLIGENT FIRE ALARM SYSTEM Supplying, installation, testing & commissioning of addressable manual call point complete as required. |
| 248 | INTELLIGENT FIRE ALARM SYSTEM Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. |
| 249 | INTELLIGENT FIRE ALARM SYSTEM Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. |
| 250 | INTELLIGENT FIRE ALARM SYSTEM Supplying, installation, testing & commissioning of response indicator on surface/ recessed MS Box having two LED, metallic cover complete with all connections etc as required. |
| 251 | INTELLIGENT FIRE ALARM SYSTEM Supplying, installation, testing & commissioning of fault isolator complete with base as required. |
| 252 | INTELLIGENT FIRE ALARM SYSTEMSupplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. |
| 253 | CABLING & WIRING Supplying & laying of 2x1.5 sq mm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 254 | Supplying, Installation, testing & commissioning of external power supply unit provides regulated and filtered 24 VDC power for hooter operation.Battery backup with built in charging. |
| 255 | Supply, Installation, Integration and Commissioning of analog addressable Single Loop Fire Alarm Control Panel having capacity upto 4 loop cards, onboard USB Protocol, RS-485 Connectivity, touch pad, each loop shall support minimum 250 devices, connectivity via modbus, ethernet, construction 16 guage CRCA sheet with powder coated finish, IP 50 Indoor, including 1 no analogue addressable loop card complete. Make: Ravel/Agni/ASES or equivalent |
| 256 | Fire Extiguishers & Photo luminescent Signages |
| 257 | Supply & installation of CO2 type fire extinguisher of 4.5 kgs. Make SAFEX / MINIMAX / CEASEFIRE or equivalent (ISI approved) |
| 258 | Supply & installation of ISI ABC type fire extinguisher of 4 kgs. Make SAFEX / MINIMAX / CEASEFIRE or equivalent |
| 259 | Supply & Installation of photoluminescent signage in rigid sheet of standard size. (FIRE EXTINUISHER/FIRE DUCT/ NO SMOKING/ FIRE ALARM CALL POINT/EXIT/FIRE EXIST). To be installed on wall or hanging as required. |
| 260 | Supply & installation of water mist type fire extinguisher of 9 liters. Make SAFEX / MINIMAX / CEASEFIRE or equivalent |
| 261 | Supplying & Installing of Clean agent based automatic modular fire extinguisher (ceiling mounted) suitable for A,B,C class fires & electrical fires, Capacity - 5 kg Make : SAFEX/MINIMAX/CEASEFIRE or equivalent Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy