| 1 | E & M Division Items |
| 2 | Dismantling of old unserviceable/damaged ACSR or AAC conductors of any size , jumper from overhead line & stacking serviceable & non serviceable material separately complete all as specified and directed. |
| 3 | Dismantling of old unserviceable/damaged stay assembly embedded in concrete including demolition of PCC and removing unserviceable meterials from site of work complete all as specified and directed. |
| 4 | Dismantling old unservicable RCC/steel poles/struts of any size including breaking up PCC foundation complete all as specified and directed. |
| 5 | Dismantling of cross-arms of MS channel or angle of any sections complete all as specified and directed. |
| 6 | Dismantling of insulators of any size/type complete all as specified and directed. |
| 7 | Dismantling earth wire or copper conductor/ cradles/stay /service feeder or distribution span complete all as specified and directed |
| 8 | Taking down or out existing cable of sizes 2/3.5/4 core 10 sqmm to 70 sqmm from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by Engineer in charge Note :(1) Excavation / cutting of road or floor/ GI pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule |
| 9 | Taking down or out existing cable of sizes 95 sqmm to 300 sqmm 3.5 core from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by Engineer in charge Note :(1) Excavation / cutting of road or floor/ GI pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule |
| 10 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed. |
| 11 | Excavation in trenches not exceeding 1.5m wide and beyond the first 1.5m in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed. |
| 12 | Returning, filling in trenches with soil obtained from excavation including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed. |
| 13 | Removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all all as specified and as directed. |
| 14 | Supply and laying burnt bricks of sub-class 'B' of size 230x115x75mm laid in trenches for cable protection complete all as specified and as directed |
| 15 | Supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. Note: Thickness of sand cushioning after punning down will be measured and paid separately. |
| 16 | M & L for PCC 1:2:4, type B-2, using 40mm graded stone aggregate as in foundations, filling and mass concrete of poles complete all as specified and directed by Engr-in-charge. |
| 17 | M & L for PCC 1:3:6, type C-1, using 20mm graded stone aggregate add in coping of poles including necessary form work complete all as specified and directed by Engr-in-charge. |
| 18 | Material and labour for trimming, cutting of various sizes of tree branches which are touching to LT over head line at various places and clear the LT over head line upto 3 mtr from conductor to tree along pole to pole all as specified and directed.Note : (a) All the safety equipments, cutting materials, ladder etc required for the above job shall be arrange by the contractor. (b) RM is measured as effected RM of over head line. (c) The cutting shall be done two times during the contact period & length in RM as one time shall be measured & paid for . |
| 19 | Supply only 40mm to 80mm graded stone aggreagates complete all as specified and directed. |
| 20 | M&L for aluminum conductor steel reinforced (ACSR) conductor, as in overhead electric line and stretching the same with required span, standard sag and binding the conductor with pin/shackle insulator and jumpers with aluminum binding wire not less than 2.00mm dia complete all as specificed and directed. |
| 21 | Labour only for restringing, tightening of loose/broken ACSR/ABC conductor of any size and type for 3 phase 4 wire system, maintaining standard sag including biding the conductor with pin/shackle insulator and jumpers with aluminum binding wire not less than 2.00mm dia on LT over head lines complete all as specified and directed.Note: (a) T&P required shall be arranged by the contractor. |
| 22 | Material and labour for stay assembly completed with all accessories as shown in electrical plate No 1 of SSR 2009 Part I (Loop type insulator, stay clamps, stay strand, excavation and conerete shall be measured separately) using 16 mm dia stay rod complete all as specified and directed. |
| 23 | Material and labour for steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP- 31 (9.0mtr long)confirming to IS-2713 (Part I & II) incl painting of pole with two coats of aluminium paint over a coat of red oxide zink chrome primer from top of the pole to 1.5m above the bottom of the pole and painting with two coats of black bituminous paint over a coat of red oxide zinc chrome primer upto 1.5m from bottom of the pole incl numbering of poles including dismantling of old u/s one complete all as specified and directed. Note : Excavation, earth work and PCC shall be measured and paid separately under respective items. |
| 24 | Material and labour for cross arm bracings,supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of zinc chrome primercomplete all as specified and directed. |
| 25 | Refixing only for cross arm bracings, supports, clamps and back plates fabricated from structural steel sections including new nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of zinc chrome primer complete all as specified and directed.Note: Old serviceable material obtained from Serial Item No 4 shall be re-used under this item. |
| 26 | S&F loop type insulator, vitreous porcelain, white, brown or green, small size with overall dimension 90 x 140mm clearance of hole 25.5mm complete all as specified and directed. |
| 27 | S&F pin type insulator porcelain vitreous, white, brown or green including one galvanized mild steel spindle, two galvanized iron washer and one galvanized iron nut 100 mm height, 65 mm dia for 1100 volts grade complete complete all as specified and directed. |
| 28 | S&F shackle type porcelain vitreous white, brown or green insulator of size 75 mm height 90 mm dia including MS strips 31X3 mm washers, insulator bolts 12 mm dia & nuts suitable for working pressure 1100 volts grade complete all as specified and directed. |
| 29 | Fixing only insulator any type and any shape (except disc type insulator) complete all as specified and directed.Note: Old serviceable material obtained from respective Serial Item No shall be re-used under this item. |
| 30 | Material and labour for cradle guard, hexagonal/rectangular or as per existng shape fabricated with galvanised steel wire 4 mm dia including binding the guards with cradle supporting GI wire and setting aside complete all as specified and directed. |
| 31 | Material and labour for galvanised stay strand of size 7mm/4mm including securing with LT pole clamp and stay clamp complete all as specified and directed. |
| 32 | Taking out old existing earthing and M&L for new Earthing complete for with copper earth plate electrode 600mm x 600mm x 3.15mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) vertically, with top edge of plate not less than 1.5 metre below normal ground level connected to copper strip 20mm X 3mm main earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron and protected with 40mm dia light grade GI pipe all as shown in electrical plate No 3 of MES Schedule Part-I connecting to earthing test point & to main switch board and testing on completion with and including necessary excavation and earth work in any type soil, earth lead connected to earth test point & to main switch board etc with & including adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, internal surface of concrete shall be given 10mm thick plaster in CM 1:4, pre cast RCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) 40mm thick cover, reinforced with 8mm dia deformed or TMT bars 3 Nos both way with 12mm dia round bar handle, GI medium grade watering pipe 20 mm dia with funnel and wire mesh and 40mm dia GI light grade earth lead protection pipe etc complete all as specified and directed. Note: Location-machinery equipment installed at power house/sub station |
| 33 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 10 sqmm 4 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 34 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 16 sqmm 4 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 35 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 25 sqmm 4 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 36 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 35 sqmm 4 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 37 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 50 sqmm 3.5core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 38 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 70 sqmm 3.5core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 39 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 95 sqmm 3.5core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 40 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 240 sqmm 3.5core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 41 | M&L GI tube medium grade 80 mm bore for protection of cable including dismantling of old u/s one complete all as specified and directed. |
| 42 | M&L GI tube medium grade 50 mm bore for protection of cable including dismantling of old u/s one complete all as specified and directed. |
| 43 | M&L GI tube medium grade 40 mm bore for protection of cable including dismantling of old u/s one complete all as specified and directed. |
| 44 | Supply and fix MCCB 4 Pole, 415V, adjustable thermal and fixed magnetic type, Ics=100% Icu, 400 Amps with breaking capacity 36KA, conforming to IS/IEC:60947-2 including taking down of existing one of any description complete all as specified and directed. |
| 45 | Supply and fix MCCB 4 Pole, 415V, adjustable thermal and fixed magnetic type, Ics=100% Icu, 250 Amps with breaking capacity 25KA, conforming to IS/IEC:60947-2 including taking down of existing one of any description complete all as specified and directed. |
| 46 | Supply and fix MCCB 4 Pole, 415V, adjustable thermal and fixed magnetic type, Ics=100% Icu, 200 Amps with breaking capacity 25KA, conforming to IS/IEC:60947-2 including taking down of existing one of any description complete all as specified and directed. |
| 47 | Supply and fix MCCB 4 Pole, 415V, adjustable thermal and fixed magnetic type, Ics=100% Icu, 160 Amps with breaking capacity 25KA, conforming to IS/IEC:60947-2 including taking down of existing one of any description complete all as specified and directed. |
| 48 | Supply and fix MCCB 4 Pole, 415V, adjustable thermal and fixed magnetic type, Ics=100% Icu, 100 Amps with breaking capacity 25KA, conforming to IS/IEC:60947-2 including taking down of existing one of any description complete all as specified and directed. |
| 49 | Supply and fix MCCB 4 Pole, 415V, adjustable thermal and fixed magnetic type, Ics=100% Icu, 63 Amps with breaking capacity 16KA, conforming to IS/IEC:60947-2 including taking down of existing one of any description complete all as specified and directed. |
| 50 | Supply & replace 250 A 4 Pole Change over switch, 50 KA, 415V, 50 Hz, AC supply, I - O - II operation, manual type, open construction or closed type construction as per site reuirement, adjustable type of thermal and megnatic setting, handel, including necessary cable lugs & wire etc complete all as specified and directed. |
| 51 | Supply & replace 100 A 4 Pole Change over switch, 50 KA, 415V, 50 Hz, AC supply, I - O - II operation, manual type, open construction or closed type construction as per site reuirement, adjustable type of thermal and megnatic setting, handel, including necessary cable lugs & wire etc complete all as specified and directed. |
| 52 | Supply & replace 63A 4 Pole Change over switch, 50 KA, 415V, 50 Hz, AC supply, I - O - II operation, manual type, open construction or closed type construction as per site reuirement, adjustable type of thermal and megnatic setting, handel, including necessary cable lugs & wire etc complete all as specified and directed. |
| 53 | Supply and replace including taking down aluminium lugs suitable for 240 Sqmm LT UG XLPE aluminium conductor Cable including nuts, bolts and washers complete all as specified and as directed. Make : Sona cable sockets / swastic / Dowells |
| 54 | Supply and replace including taking down aluminium lugs suitable for 185/150 Sqmm LT UG XLPE aluminium conductor Cable including nuts, bolts and washers complete all as specified and as directed. Make : Sona cable sockets / swastic / Dowells |
| 55 | Supply and replace including taking down aluminium lugs suitable for 120 Sqmm LT UG XLPE aluminium conductor Cable including nuts, bolts and washers complete all as specified and as directed. Make : Sona cable sockets / swastic / Dowells |
| 56 | Supply and replace including taking down aluminium lugs suitable for 95 Sqmm LT UG XLPE aluminium conductor Cable including nuts, bolts and washers complete all as specified and as directed. Make : Sona cable sockets / swastic / Dowells |
| 57 | Supply and replace including taking down aluminium lugs suitable for 70 Sqmm LT UG XLPE aluminium conductor Cable including nuts, bolts and washers complete all as specified and as directed. Make : Sona cable sockets / swastic / Dowells |
| 58 | Supply and replace including taking down aluminium lugs suitable for 50 Sqmm LT UG XLPE aluminium conductor Cable including nuts, bolts and washers complete all as specified and as directed. Make : Sona cable sockets / swastic / Dowells |
| 59 | Supply and replace including taking down aluminium lugs suitable for 35/25 Sqmm LT UG XLPE aluminium conductor Cable including nuts, bolts and washers complete all as specified and as directed. Make : Sona cable sockets / swastic / Dowells |
| 60 | Supply and replace including taking down aluminium lugs suitable for 16/10 Sqmm LT UG XLPE aluminium conductor Cable including nuts, bolts and washers complete all as specified and as directed. Make : Sona cable sockets / swastic / Dowells |
| 61 | Design, engineering, supply, installation, testing & commissioning of 1.1KV XLPE Aerial Bunched Cable line on existing poles of size 3 core x 16sqmm + 1 core x 25 sqmm consisting of all accessories such as MS flat, suspension clamp with pole bracket and steel strap, dead end/anchor clamp with pole bracket and steel strap , insulation piercing connectors, cable end cap etc as per site complete all as specified and as directed. |
| 62 | Design, engineering, supply, installation, testing & commissioning of 1.1KV XLPE Aerial Bunched Cable line on existing poles of size 3 core x 16sqmm + 1 core x 25 sqmm consisting of all accessories such as MS flat, suspension clamp with pole bracket and steel strap, dead end/anchor clamp with pole bracket and steel strap , insulation piercing connectors, cable end cap etc as per site complete all as specified and as directed. |
| 63 | Supply and replace including taking down forging & bending mild steel MS eye bolt for hanging AB cable including nuts, bolts and washers complete all as specified and as directed. |
| 64 | Supply and replace including taking down strain clamp of any type for hanging AB cable including nuts, bolts and washers complete all as specified and as directed. |
| 65 | Supply and replace including taking down dead end clamp of any type for hanging AB cable including nuts, bolts and washers complete all as specified and as directed. |
| 66 | Supply and replace including taking down ABC piercing connector of any type and cable of size 16 sqmm to 95 sqmm for AB cable including nuts, bolts and washers complete all as specified and as directed. |
| 67 | Supply and fixing including taking down copper strip 20mm X 3.15 mm with fixing screws for conductors/ earth lead including brazing and nut bolts jointing at all joints for building/ equipment laid through pipe/ trench/ surface complete all as specified and directed. Please Enable Macros to View BoQ information |