| 1 | GENERAL SUMMARYNOTE: Schedule ‘A’ Part - I to XII are prepriced by MES under Ser No. 02 to 13. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. |
| 2 | Lumpsum price worked out by the tenderer for \\"BUILDINGS/STRUCTURES\\" as listed in Schedule ‘A’ Part- I |
| 3 | Lumpsum price worked out by the tenderer for \\"EXCAVATION & EARTHWORK INCLUDING SITE CLEARANCE AND LAND DEVELOPMENT\\" as listed in Schedule ‘A’ Part- II |
| 4 | Lumpsum price worked out by the tenderer for \\"INTERNAL WATER SUPPLY\\" as listed in Schedule ‘A’ Part- III |
| 5 | Lumpsum price worked out by the tenderer for \\"INTERNAL ELECTRIFICATION \\" as listed in Schedule ‘A’ Part- IV |
| 6 | Lumpsum price worked out by the tenderer for \\"ROAD/HARD STANDING /PATH \\" as listed in Schedule ‘A’ Part- V |
| 7 | Lumpsum price worked out by the tenderer for \\"SEWAGE DISPOSAL\\" as listed in Schedule ‘A’ Part- VI |
| 8 | Lumpsum price worked out by the tenderer for \\"AREA DRAINAGE\\" as listed in Schedule ‘A’ Part- VII |
| 9 | Lumpsum price worked out by the tenderer for \\"EXTERNAL WATER SUPPLY\\" as listed in Schedule ‘A’ Part-VIII |
| 10 | Lumpsum price worked out by the tenderer for \\"EXTERNAL ELECTRIC SUPPLY\\" as listed in Schedule ‘A’ Part- IX |
| 11 | Lumpsum price worked out by the tenderer for \\"COOLING AND HEATING APPLIANCES\\" as listed in Schedule ‘A’ Part- X |
| 12 | Lumpsum price worked out by the tenderer for \\"PILE FOUNDATION\\" as listed in Schedule ‘A’ Part- XI |
| 13 | Lumpsum price worked out by the tenderer for \\" PCC/RCC RETAINING WALL\\" as listed in Schedule ‘A’ Part- XII |
| 14 | Subtotal |
| 15 | NOTE: Schedule ‘A’ Part - XIII \\"MICELLANEOUS ITEMS\\" is not prepriced by MES and prepriced rate indicated as 0.00 under Col.5 signifies this fact only. Bidder shall insert their rates in Green colour filled under Col-6. |
| 16 | Schedule ‘A’ Part-IV ( INTERNAL ELECTRIFICATION ) |
| 17 | Supply and fix Air circulator fan 600 mm sweep , complete with three blade, and connecting accessories 230V complete all as specified and as directed. Make- Havells cat No- FHACWSTSCL24 or equivalent in CG, Orient, Bajaj. |
| 18 | M & L for Wiring for circuit/submain wiring alongwith PVC Insulated Copper Conductor (Flexible) FRLSH , industrial cables in suitable size PVC Conduit, 1100 volts to IS: 694, of size 4 sqmm x 3Core for Three Phase Machines in Workshop machine and Highbay Light Fitting in workshop area complete all as specified and as directed. |
| 19 | M & L for Wiring for circuit/submain wiring alongwith PVC Insulated Copper Conductor (Flexible) FRLSH , industrial cables in suitable size PVC Conduit, 1100 volts to IS: 694, of size 4 sqmm x 4Core for test lamp panel complete all as specified and as directed. |
| 20 | S & F 100 Watts LED type High Bay light fitting with very high efficiency round highbay in PDC housing suitable for industrial application. The luminaire has efficiancy upto 150 Lum/W to reduce quantity/wattage thereby reducing operational cost. Ingress protection of IP66 with additional safety chain, complete all as specified and as directed. Make CG, Cat Part No :CIP 320-100-57-60D-HL4-GL-NSR or equivalent in Havells/ Philips. |
| 21 | Schedule ‘A’ Part-VI (SEWAGE DISPOSAL) |
| 22 | M&L for RCC Septic tank for 25 users :-RCC Septic tank Conventional type designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., with effective depth of 1.5 meter and overall depth of 3 meter complete all as shown on drawing CE/TD/2022/16 Sht 1/1 as directed and specified. |
| 23 | Soakage well 2.25 M dia X 1.8 M effective depth :- M&L for Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of suitable size complete all as shown on drawing CE/TD/2022/17 Sht 1/1 as directed and specified. |
| 24 | Soakage well 1.6 M dia X 1.5 M effective depth :- M&L for Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of suitable size complete all as shown on drawing CE/TD/2022/17 Sht 1/1 as directed and specified. |
| 25 | M&L for RCC Septic tank for 50 users :-RCC Septic tank Conventional type designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls , Base Slab , Baffle walls and Roof Slab including beams etc with Vent shaft , manhole openings with cover connection etc., with effective depth of 1.5 meter and overall depth of 3 meter complete all as shown on drawing CE/TD/2022/16 Sht 1/1 as directed and specified. |
| 26 | Schedule ‘A’ Part-VIII (EXTERNAL WATER SUPPLY) |
| 27 | Cutting the existing GI pipe line of 80 mm dia and inserting 50 mm dia GI pipe line including all connected acessories,excavation,returning and refilling complete all as directed. |
| 28 | Construction of masonry valve chamber, 100 mm thick foundation using PCC 1:4:8, type D-2, over 15cm thick hard core, 20cm thick solid block masonry with blocks cast using PCC 1:3:6, type C-1, set in cement mortar 1:4, 15MM thick plaster to internal surfaces and external surfaces up to 15cm below ground level and top of floor in cement and sand mortar 1:4, finished even and smooth with out using extra cement , 3.15mm thick MS sheet cover including 50mmX50mmX6mm thick MS angle frame fixed in PCC 1:2:4, type B1 coping with 25mmX6mm flat iron hold fasts, handle, hinges with locking arrangements, applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surfaces and earth work in any type of soil including disposal of surplus soil to a distance not exceeding 50M complete all as specified and shown on drawing for internal size: 600 x600x600mm. |
| 29 | Schedule ‘A’ Part-IX (EXTERNAL ELECTRIC SUPPLY) |
| 30 | Supply, install, testing and commissioning of distribution transformer stepdown, outdoor type, 100 KVA floor mounted 11000V/433V with HT 3 ph and LT 3 ph - 4 wire system, copper wound level 2 with 'F' class insulator with off load tap changing arrangement on HT side for a variation of secondary voltage +/- 7.5% in steps of 2.5% continous of 100 KVA confirming to IS-2026 with and including followings:-(a) Lifting hooks, rollers for transformer and tank(b) Earthing terminal and rating and diagram plate(c) Air release device(d) Oil filling inlet pipe with plug(e) Drain outlet pipe with brass gate vlave with dummy plug(f) Conservator with oil level gauge(g) Silica gel breather |
| 31 | (h) First oil fill up to the recommended level by the manufacturer with new oil confirming to IS-335(j) Type of connection delta for HT side and star with neutral connection on LT side(k) Type of cooling ONAN(l) Vector group DYN - 11(m) Type of connection HT insulator on HT side and cable terminator box on LT side(n) Provision of thermometer 0° to 100°C with pocket(o) Suitable foundation /platform 1.5 x 1.5 x 1 as per manufacturer instructions. |
| 32 | Supply, install, testing & commissioning of factory made, Outdoor type 11 KV, 3 Phase, 3 way RMU with one number incomer VCB and two numbers outgoing LBS and tested for 21 KA for 1 Sec with AFLR clssification:-Load Break Switch:-11 KV,630 Amps, 21 KA LBS consists of an SF6 cubicle housing a switch disconnector and an earthing switch.Bus bars and all electrical connections are located inside the tank. The switch positions are closed-open - earthed. The operating shafts for the switches should have rotary seals where they enter the SF6 cubicle. The operating mechanisms should be located outside in front of the SF6 tank. Cable bushings should be located on the side/rare of the SF6 cubicle in a seperate cable compartment. Front covers containing the mimic diagram and having a degree of protection IP2X close the fronts. |
| 33 | Vacuum Circuit Breaker:-11 KV, 630 Amps, 21 KA VCB module should consists of an SF6 cubicle housing a fixed type Vacuum Circuit Breaker and a series disconnector and earth switch. An integrated relay and related CTs is used for tripping of the circuit breaker. Use of SF6 as Fault interruption media is not allowed because of safety and envirenmental reasons. Bus bar and all electrical connections should be located inside the tank. The operating shafts for the switches should have rotary seals where they enter the SF6 cubicle. The circuit breaker used shall be of same make as that of RMU. The operating mechanisms are located outside on the front side of the SE6 tank. Bolted type cable bushings should be located on the front of the SF6 cubicle in a seperate cable compartment: Front covers containing the mimic diagram and having a degree of protection IP2X seal off the fronts. Vacuum bottles should be used as interrtupters of the fault currents. The make of Vacuum bottle should be same as that of RMU. The circuit breaker main circuit should be connected in series with a three position disconnector-earthing switch the operation between circuit breaker and disconnector earthing must be interlocked.VCB shall use a self powered relay with low burden trip coil Relay shall draw the required engerav from rina core CTs mounted on cable bushings CT |
| 34 | Bus Bars:-The three nos. of continuous Bus bars made up of EC grade copper of rating current 630A shall be provided. Type tests:-(i) RMU should be type tested in accordance with IEC standards 60056, 62271-102,60265,62271-200,62271-105,60529 and 60694.(ii) short time and peak withstand current test.(iii) temperature rise tests(iv) Dielectrictric tests (v) Arc fault test (vi) mechanical endurance test(vii) Duty cycle test (viii) Internal arc test for HT chamber (ix) Tests to verify true postion indication devices as per IEC 62271-102.All this type test reports has to be submitted during supplying the RMU.Make: ABB/siemens/Schneider. |
| 35 | The RMU switchgear shall comply with the requirement stated in the following standards and specifications amended upto date: 3.0 APPLICABLE STANDARDS The RMU switchgear shall comply with the requirement stated in the following standards and specifications amended upto date. IEC 62271-200/ IEC 60298/ IS 12729: 1988 -General requirement for metal enclosed switchgear. IEC 62271-100/ IEC 60056/ IS 13118: 1991-Specification for alternating current breakers. IEC 62271-1/ IEC 60694-Panel design, SF6/vacuum circuit breakers. IEC 60129/ IEC 62271- 102/ IS 9921-Alternating current disconnetors (Load Brak Isolators) and earthing switch. IEC 60044-1/ IEC 60185/ IS 2705:1992-Current Transformers. IEC 376-Filling of SF6 gas in RMU. IEC 60273/ IS 13947 (Part)-Dimension of indoor & outdoor post insulators with voltage> 1000V. IEC 60129/ IEC 62271- 102/ IS 9921-Degree of protection provided by enclosures for low voltage switchgear and control gear. All india electricity rules/bills amended up to date applicable for clearances, safety and operation of the equipment. |
| 36 | M&L for testing and Earthing complete withgalvanised steel earth plate elecrode of size 60×60cm× 6mm thick , buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to GI earth strip of size 32 x 6 mm by means of bolts, nuts, check nuts and washers ofwashers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point and and necessary excavation and earth work PCC (1:2:6) type C-1 with suitable size of CI cover plate with angle iron frame and opening arrangement ) incl providing copper sulphate and salt in alternate layer of 15 cm compacted thickness all around the earth electrode with funnel and 20 mm bore galvanized iron watering pipe ( light grade) wire mesh, copper lugs, complete in all respect,protected by 40 mm bore (light grade) galvanized iron pipe up to earthing test point as directed, incl disposal of spoil to a distance not exc 50 mtr and necessary testing on completion complete all as specified and as directed by the Engineer-in-charge. Note: (i) Cost of GI earth strip and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item(ii) The unit rate shall also includes for Wire mesh, funnel, excavation, PCC chamber pit, test point complete. |
| 37 | M&L for PCC cable route indicator of size 45cm x 25cm x 7.5cm duly grouted 15 cm below ground level in PCC 1:4:8 type D-2, top edges chempered and writing HT 11KV CABLE duly grouted on both sides complete all as specified and as directed by the Engineer-in-charge |
| 38 | M&L for trenching cutting 150mm dia bore hole manually or machinery not less than 1.5 mtr deep without damage the existing structure complete all as specified and as directed by the Engineer-in-charge. |
| 39 | Supply, install, testing and commissioning Out door type of factory fabricated LT panel made out of 3.15 mm thick CRCA sheet and angle iron of size 40 x 40 x 5 mm floor mounted type with Aluminium bus bar of capacity 400 Amp- 4 Nos including two coats of spary synthetic enamel paint over a coat of red oxide, including voltmeter, ammeter, with necessary CTs & PTs, selector switches, phase indication lamps for three phase system, control panel & power panel wiring, cable alleys at both side, confirming to IS:8623, IEC:60439 & CPRI Approved, protection class IP65 with the accessories housing with the following switch gears:-(For Transformer)(i) MCCB 4P, 415V, 50 Hz Adjustable type, 200 Amps, 25 KA -01Nos as Incommer(ii) MCCB 4P, 415V, 50 Hz Adjustable type, 125 Amps, 25 KA - 02 Nos (01 for Casu & 01 Spare) |
| 40 | (iii) MCCB 4P, 415V, 50 Hz Adjustable type, 63 Amps, 25 KA - 01 Nos (spare)(iv) MCB SPN 32 Amps -02 Nos (Spare)(iv) Voltmeter 0-500volts with selector switch(v) Amp meter 0-200 Amps TP 415 Volts 01 No with selector switch & CTS(vi) Indicating lamp R-Y-B- 1 set(vii) Alumn busbar for phase & neutral(viii) Earthing connecting points(ix) Cable entry facility in-out with glands |
| 41 | Supply ,install, testing and commissioning LT floor mounted cubical type electric panel factory fabricated with CRCA sheet 2mm thick of size 2 x 2.5 x0.5Mt & 40 x 40 x 5mm thick angle iron frame work duly painted with powder coated heat resistant paint, comprising the following accessories & confirming to IP 52 protection class & CPRI approved with the following accessories (For Engineering Shop & Electronic Shop)(i) MCCBs 4P, 415V, 63 Amps, 16 KA-01 As Incommer(ii) MCB TP 415V, 32A - 04Nos(iii) MCB SPN 5-32 Amps- 06 Nos(iv) Voltmeter 0-500 volts with selector switch(v) Amp meter 0-100 Amps TP 415 Volts 01 No with selector switch & CTS(vi) Indicating lamp R-Y-B- 1 set (vii) Alumn busbar for phase & neutral(viii) Earthing connecting points(ix) Cable entry facility in-out with glands Please Enable Macros to View BoQ information |
| 42 | Supply ,install, testing and commissioning LT floor mounted cubical type electric panel factory fabricated with CRCA sheet 2mm thick of size 2 x 2.5 x0.5Mt & 40 x 40 x 5mm thick angle iron frame work duly painted with powder coated heat resistant paint, comprising the following accessories & confirming to IP 52 protection class & CPRI approved with the following accessories (For Engineering Shop & Electronic Shop)(i) MCCBs 4P, 415V, 63 Amps, 16 KA-01 As Incommer(ii) MCB TP 415V, 32A - 04Nos(iii) MCB SPN 5-32 Amps- 06 Nos(iv) Voltmeter 0-500 volts with selector switch(v) Amp meter 0-100 Amps TP 415 Volts 01 No with selector switch & CTS(vi) Indicating lamp R-Y-B- 1 set (vii) Alumn busbar for phase & neutral(viii) Earthing connecting points(ix) Cable entry facility in-out with glands Please Enable Macros to View BoQ information |