Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Cleaning and grubbing road land including uprooting vegetation, grass, bushes, shrubs, saplings and trees girth upto 300mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable materials to be used or auctioned, upto a lead of 1000m including removal and disposal of top organic soil not exceeding 150mm in thickness. |
| 2 | Earth work in excavation in foundation in Hard soil including hard moorum, with all leads and lifts including dressing and leveling the bed and depositing the excavated earth at place away from work site with all leads and lifts including cost of all labour and T&P and dewatering if required for the work etc. complete and as directed by the Engineer-in-charge. |
| 3 | Filling foundation and plinth with excavated materials including watering and ramming complete in all respect as directed by the Engineer-in-Charge |
| 4 | Providing Sand filling in foundation of structures/ Behind abutment wing walls & return wall as per approved drawing and technical specifications as per Section 300 ,2100 & 2200 of MoSRT&H Specifications for Road & Bridge works (5th Revision) including cost, conveyance, taxes, cess, royalties of all materials, cost of all labour, T&P required for the work etc. complete as per specification & direction of Engineer-in-charge |
| 5 | Providing and laying plain cement concrete 1:4:8 agregate 40mm nominal size as levelling course in floor and plinth including tempering, curring, shuttering etc. complete all depth and height including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge. |
| 6 | Providing and lying Plain Cement Concrete of proportion (1:3:6) in foundation and floors using 4cm (1 1/2inch) 0 mm & down grade black hard crusher broken granite stone metal, washed and screened sharp sand of approved quality from approved quarry including hoisting, lowering, laying the concrete, ramming, watering and curing etc. complete to required thickness including cost of all materials, conveyance, loading, unloading,cost of labours, T&P, hire & running charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -charge. |
| 7 | Providing, lifting, hoisting and laying Reinforced cement concrete of M-25 grade as per approved designs and drawings having a minimum compressive strength (in work test) 200 Kg. / Square cm. in 15 cm. cubes at 28 days after mixing and test conducted in accordance with I.S. 516 using 12 mm. to 20 mm. size black hard crushed broken granite stone chips and screened and washed sharp sand for mortar of approved quality from approved quarry, washed and cleaned ( 20mm. size chips not to exceeds 25 percent ) to be mixed in concrete mixture with Portland slag cement (PSC) including hoisting, lowering, laying and compaction concrete by using vibrators, watering and curing for 28 days, centering and shuttering then after dismantling and removing debris from the work site and finishing the exposed surface smooth providing grooves or beads wherever necessary including cost, conveyance, loading, unloading, royalties of all materials and cost of all labours, sundries, T & P required of the work etc. complete in all respect as directed by the Engineer-in-Charge. But excluding cost and conveyance of M.S. rods or Tor steel and binding wires and labour charges for straightening, cutting, bending etc. of M.S. rods or tor steel tying the grills and placing in proper position complete as per direction of Engineer-In -Charge. A.( FOOTING ) |
| 8 | B.COLUMN UPTO PLINTH |
| 9 | C.COLUMN SUPER STRUCTURE(G.F) |
| 10 | 1ST FLOOR |
| 11 | 2ND FLOOR |
| 12 | Terrace Floor |
| 13 | D. PLINTH BAND |
| 14 | E. LINTEL BAND(G.F) |
| 15 | 1ST FLOOR |
| 16 | 2ND FLOOR |
| 17 | Terrace Floor |
| 18 | F. FLOOR BEAM (G.F) |
| 19 | 1ST FLOOR |
| 20 | 2ND FLOOR |
| 21 | Terrace Floor |
| 22 | G. CHAJJA (G.F) |
| 23 | 1ST FLOOR |
| 24 | 2ND FLOOR |
| 25 | Terrace Floor |
| 26 | H.ROOF SLAB (G.F) |
| 27 | 1ST FLOOR |
| 28 | 2ND FLOOR |
| 29 | Terrace Floor |
| 30 | I .STAIRCASE(G.F) |
| 31 | 1ST FLOOR |
| 32 | 2ND FLOOR |
| 33 | water tank Terrace |
| 34 | Supplying, Cutting, Straightening coiled or bent up M.S. rods or Tor steel of SAIL(HYSD Fe-500) welding or jointing if necessary, bending, binding, tying the grills and laying in position as required for R.C.C. works and hoisting, lowering and placing in position in all floors according to approved designs and drawings including cost, conveyance, of M.S. rods or Tor steel and binding wires of 18 to 20 gauge required for the work and cost of all labour, sundries, T&P etc. complete in all respect as directed by the Engineer-in-charge All reinforcement steel and structural steel shall be procured from primary producers of steel-SAIL/RINL/TATA/JINDAL(Panther)/SHYAM STEEL. GROUND FLOOR |
| 35 | 1ST FLOOR |
| 36 | 2ND FLOOR |
| 37 | Terrace Floor |
| 38 | Brickwork with Fly ash bricks in cement mortar (1:6) in F&P (23cm x 11cm x 8 cm) having minimum crushing strength not less than 75 kg.per.sq.cm. including splays cutting, circular moulding, chamfering, corbelling and similar such type of woks with all necessary projections watering and curing for 7 days after immersing the bricks in water for six hours before use etc. complete including cost and conveyance of all materials, labour with T&P required for the work and royalties etc. complete in all respect as per direction of Engineer in charge. |
| 39 | Brickwork with Fly ash bricks in cement mortar (1:6) in Superstructure (23cm x 11cm x 8 cm) having minimum crushing strength not less than 75 kg.per.sq.cm. including splays cutting, circular moulding, chamfering, corbelling and similar such type of woks with all necessary projections watering and curing for 7 days after immersing the bricks in water for six hours before use etc. complete including cost and conveyance of all materials, labour with T&P required for the work and royalties etc. complete in all respect as per direction of Engineer in charge. GROUND FLOOR |
| 40 | 1ST FLOOR |
| 41 | 2ND FLOOR |
| 42 | Terrace Floor |
| 43 | Brick work with Fly ash Bricks 23cm x 11cm x 8cm size having crushing strength not less than 75Kg/cm2 with dimensional tolerance ±2 percent in cement mortar (1:4) in Superstructure including watering curing, cost of carriage and royalty of all materials, taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge. GROUND FLOOR |
| 44 | 1ST FLOOR |
| 45 | 2ND FLOOR |
| 46 | 12mm (1/2 inch) thick cement plaster in cement mortar (1:6) finished smooth to brick walls after raking out the joint including watering and curing for seven days with cost and conveyance of all materials and labour with T& P required for the work and royalities etc. complete in all respect as per direction of Engineer in charge. GROUND FLOOR |
| 47 | 1ST FLOOR |
| 48 | 2ND FLOOR |
| 49 | Terrace Floor |
| 50 | 16mm (5/8 inch) thick cement plaster (1:6) finished smooth to inside of 9/10 thick brick walls after raking out the joint including watering, curing for seven days with cost and conveyance of all materials and labour with T&P required for the work and royalities etc. complete in all respect as per direction of Engineer in charge. GROUND FLOOR |
| 51 | 1ST FLOOR |
| 52 | 2ND FLOOR |
| 53 | Terrace Floor |
| 54 | 6mm thick cement plaster (1:4) finished smooth to R.C.C surfaces finished smooth including closed deep chipping and slurry treatment including watering, curing for seven days with cost and conveyance of all materials and labour with T&P required for the work with royalities etc. complete in all respect as per direction of Engineer in charge. GROUND FLOOR |
| 55 | 1ST FLOOR |
| 56 | 2ND FLOOR |
| 57 | Terrace Floor |
| 58 | Supplying, fitting & fixing of Chequered tiles in floors of approved make laid on 20 mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with slurry including cost of all materials, labour T&P etc required for the work all complete as per direction of the Engineer-in-charge. GROUND FLOOR |
| 59 | Fixing granite tiles of approved dimension area above 0.4 sqm (20mm thick) in floor, treads of steps and landing on 20mm thick bed of cement mortar (1:4) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties and taxes of all materials complete in all respects as per direction of Engineer-in-Charge.GROUND FLOOR |
| 60 | 1ST FLOOR |
| 61 | 2ND FLOOR |
| 62 | Fixing granite tiles of approved dimension area above 0.1 up to 0.4 sqm (10mm thick) in Dados, treads of steps and landing on 12mm thick cement mortar (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties and taxes of all materials complete in all respects as per direction of Engineer-in-Charge. GROUND FLOOR |
| 63 | 1ST FLOOR |
| 64 | 2ND FLOOR |
| 65 | Providing full body matt finish vitrified tile flooring using vitrified tiles having thickness of min 10mm conforming to IS 13755 of 1200x600 (homogeneous) of premium quality in floors, treads on steps and landings on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shades of the vitrified tile if required , watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour,Labour cess , sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge. GROUND FLOOR |
| 66 | 1ST FLOOR |
| 67 | 2ND FLOOR |
| 68 | Providing, fitting, fixing vitrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mm x 600mm Plain (Ivory) of approved make as directed by Engineer-in-charge in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing etc. complete with cost, conveyance, royalties of all materials all labour,labour cess complete in all respects as per specification and direction of Engineer-in-charge. GROUND FLOOR |
| 69 | 1ST FLOOR |
| 70 | 2ND FLOOR |
| 71 | Providing & Fixinng factory made 100percent Solid WPC ( Wood Polymer Composite )- Door Frame 125 mm x 65 mm Single Rebated, made from Wood Polymer Composite ( Single Extruded Process ) material comparising of virgin PVC polymer of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and Natural Fibers ( Wood Powder/ Rice Husk/ Wheat Husk ) and Non toxic additives fabricated with meter Joints after applying PVC solvent Cement & screwed with full body treaded star headed screws having minimum frame density of 780 kg/ cbm & an ISO 9001 - 2015 Certified Company, having good screw holding capacity ( Screw Withdrawal strength of ( Min. 990 N ),Minimum Compressive Strength of 58 N/mm2, Modulus of elasticity 900N/mm2 and resistance to spread of flame of class A category with property of being termite / borer proof , water / Moisture Proof & Fire retardant & Fixed in position with SS Dash Fasteners / Hold Fast of reuired dia and lenght, , all as per specifications drawings as directed by the Engineer-In-Charge. Material test certificate and authentication should be compulsory provided by the manufacturing company. GROUND FLOOR |
| 72 | 1ST FLOOR |
| 73 | 2ND FLOOR |
| 74 | Terrace Floor |
| 75 | Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fittings and fixtures etc. complete in all respect as per the direction of the Engineer-in-Charge. GROUND FLOOR |
| 76 | 1ST FLOOR |
| 77 | 2ND FLOOR |
| 78 | Terrace Floor |
| 79 | Supplying and fitting-fixing of factory made single leaf rigid FRP (alternately called GRP) sandwich composite door shutter of 32mm thick laminated with two GRP skins with wood grain finish fabricated using UV-stabilised Isopthalic Gelcoat and one layer of 450 gsm E-glass Chopped Strand Mat (CSM) impregnated with orthopthalic palyester resin. The thickness of the skins shall not be less than 3.00 mm Expanded Polystyrone (EPS) structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material. Wooden reinforcements made of seasoned sal wood block of cross section not less than 28mmx32mm and also necessary sal wood reinforcements for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, the sal wood reiforcements and the skins. The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centres standards and specifications and the door shutters tested in conformation to IS: 4020-1998. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. (Make- Fibre Space/ Neoplast) GROUND FLOOR |
| 80 | 1ST FLOOR |
| 81 | 2ND FLOOR |
| 82 | Suppling fitting fixing of openable UPVC doors with door frame of approved make with 6mm thick glass of approved quality complete with frame Shutter and all fitting and fixtures as per direction of Engineer-in-Charge. GROUND FLOOR |
| 83 | Supplying , fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures in all respect including cost of materials, conveyance, loading & unloading and taxes of all materials and cost of all labour, sundries, T & P etc. required for all the work complete as per the directions of Engineer -in-charge. GROUND FLOOR |
| 84 | 1ST FLOOR |
| 85 | 2ND FLOOR |
| 86 | Supplying, fitting, fixing of, M.S Grill for (MS Door, MS GATE ,M.S grill ,, MS Square Bar Spike to openings,tubular trusses and collapsible gate ) of approved specification and of approved size, materials and design with a coat of primer including painting two coats over a coat of redoxide primer with cost and conveyance of all materials, labour, royality, etc. complete in all respect and as per direction of Engineer-in-charge. GROUND FLOOR |
| 87 | 1ST FLOOR |
| 88 | 2ND FLOOR |
| 89 | Priming one coat with wall cement primer (water bound) to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess T&P etc. complete as per the direction of the Engineer-in-charge. GROUND FLOOR |
| 90 | 1ST FLOOR |
| 91 | 2ND FLOOR |
| 92 | Terrace Floor |
| 93 | Wall painting two coats with Antifungal weather coat paint (1st quality) exterior grade of approved make & approved shade over a coat of primer to make an even finished surface in all floors and heights with all scaffolding and staging charges including cost, conveyance, cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per the direction of the Engineer-in-Charge. GROUND FLOOR |
| 94 | 1ST FLOOR |
| 95 | 2ND FLOOR |
| 96 | Terrace Floor |
| 97 | Finishing plastered surfaces of walls with cement based wall putty (Water based) of approved make and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge. GROUND FLOOR |
| 98 | 1ST FLOOR |
| 99 | 2ND FLOOR |
| 100 | Terrace Floor |
| 101 | Painting two coats with plastic emulsion paint with a approved quality primer to make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess, T&P etc. complete as per the direction of the Engineer-in-charge. GROUND FLOOR |
| 102 | 1ST FLOOR |
| 103 | 2ND FLOOR |
| 104 | Terrace Floor |
| 105 | Painting two coat with approved synthetic enamel paint to new iron work over a coat of Red oxide primer including cost, conveyances, royalties, taxes of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge. GROUND FLOOR |
| 106 | 1ST FLOOR |
| 107 | 2ND FLOOR |
| 108 | Supplying, fitting, fixing of Stainless steel of 304 Grade in hand railing using 50mm dia of 2mm thick circular pipe with balustrade of size 32mmX32mmX2mm at 0.90mt.c/c & stainless square pipe bracing of size 32mmX32mmX2mm in 3 rows in stair case as per approved design & specification, buffing, polishing etc with cost,conveyance,, labour,T&P etc. required for the work complete in all respect in all floors as per direction of Engineer-in-Charge. GROUND FLOOR |
| 109 | 1ST FLOOR |
| 110 | 2ND FLOOR |
| 111 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone- III) derived from natural sources: 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 112 | Providing average 25mm thick grading Concrete with (1:2:2) using 6mm hard granite chips using 2percent water proofing cement compound of approved quality over top of Roof, Terrace, including cost of scaffolding, scraping and cleaning the roof surface, plastering and finishing smooth to proper slope and gradient including cost of all materials, conveyance, taxes and sundries, T&P etc. All complete in all respect as per direction of the Engineer -in-charge. (Manufacture Name of Water Proofing Compund- Sika, Fosroc, Dr. Fixit) 1ST FLOOR |
| 113 | Terrace Floor |
| 114 | Waterproofing application:- Providing and application of two component polymer modified flexible cementitious waterproofing coating at a thickness of 1.5 -2.5 mm The membrane should have Elongation equal or more than: 30percent Crack Bridging ability : Up to 1 mmAdhesive strength: 1.0 N/mm² at 28dTensile elongation: 60percent at 20°CShore A Hardness more than85 (between 3 - 7 days)etc. as per direction of E.I.C (For longer span, in terrace panel of 4m*4m should be done by groove cutting, and filling with PU Sealant) (Make-Myk, Fosroc, Sika) 1ST FLOOR |
| 115 | Terrace Floor |
| 116 | E.I work Recessed wiring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLSH/LSZH PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/ HAVELLS/RR KABLE/KEI with 20 mm dia PVC non metallic heavy conduit FRLS type ISI marked Make-AKG/BEC/Precision/Norpack/Anchor 6A modular type( flame retradant type) switch ISI marked Make-Schneider (Zencelo) /legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) ( flame retradant type) Make-Schneider (Zencelo) / legrand( Myrius) / Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLSH PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. Group-A. |
| 117 | Group-B. |
| 118 | Group-C. |
| 119 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retardant type)) with suitable size modular box & cover( falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider (Zencelo) / legrand( Myrius) /Panasonic (vision) |
| 120 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( ( flame retardant type) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) |
| 121 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)( flame retardant type) with suitable size modular box & cover( falme retardant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider ( Zencelo ) / legrand ( Myrius) / Panasonic (vision) |
| 122 | Supplying,fixing of 1x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+1 no 6A switch & socket(modular type) ( flame retardant type) with suitable size modular box & metallic cover plate (both side)( flame retardant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 123 | Supplying,fixing of 2x6A Plug on the separate board with complete fitting by 02 nos. 6A switch & socket(modular type) ( flame retardant type) with suitable size modular box & metallic cover plate (both side)( flame retardant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 124 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated single core multistrand copper conductor of ISI marked in recess PVC conduit with 2 way modular switch with ISI marked, modular base of suitable size ISI marked with metal box(18 SWG) and earthing point with 1.5 sq.mm FRLS PVC insulated single core multistrand copper conductor for loop earthing etc as required. |
| 125 | S/F of 20A Modular DP Switch with Modular GI Box and Cover Plate.Make-Schneider ( Zencelo ) / legrand ( Myrius) / Panasonic (vision) |
| 126 | Recessedwiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 127 | Recessedwiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 128 | Recessedwiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V-Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) |
| 129 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit .(LFDB TO LBDB/UBDB) (2X6+1X2.5) |
| 130 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB/Medical equipement) (4X6+2X4) |
| 131 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 6 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallic heavy duty conduit .(LFDB TO FLOOR PANEL TO TPN BDB power) (4X10+2X6) |
| 132 | MAIN PANEL S/I/T&Commissioning of CPRI Approved LT indoor floor mounted cubical type electrical main panel made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing as per direction of Engg.-in-Charge. In commer- 01 number of 630 Amps 4P LSIG MCCB,36KA with Microprocessor based Release with Communication Ports, 630A 4P changeover switch (Icu=100percentIcs) with shunt trip.with auxuliary Busbar- 04 numbers of 700Amps Al busbar duly sleeved by color coaded PVC sleeve and 01 no. busbar for Earthing & supported by suitable size DMC insulator Out going- (i) 400A 4P LSIG MCCB,25KA with Microprocessor based Release, Ics=100percentIcu- 1 No. (ii) 250A 4P LSIG MCCB,25KA with Microprocessor based Release Ics=100percentIcu- 1 No.iii) 160A 4P Thermal based MCCB,25KA with adjustable overload, Ics=100percentIcu- 3 Nos. (iv) 100A 4P Thermal based MCCB,25KA with adjustable overload, Ics=100percentIcu- 4 Nos. (v) 63A 4P MCB, C series, 10kA- 6 Nos . (vi) 40A 2P MCB, C series, 10 kA- 6 nos. Instrument- (i) phase indicating lamps with HRC fuse.(ii) 01 set of digital type multifunction meter with CT for voltage,current,frequency,PF,THD indication(iii) 01 set of 65KA TYPE1+2 4P SPD along with 63A 4P MCB, C series, 10kA.Make of MCCB-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB FormulaMake of MCB-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200Make of SPD- Legrand/Siemens/ Schneider/ ABB/OBO/Dehn |
| 133 | SITC of LT indoor floor mounted cubical type electrical lift panel made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder coated paint is designed as G.A drawing. (FOR LIFT)as per direction of Engg.-in-Charge. Warranty period of replacement of panel & accessories must be 1 year & compelete test certificate must be submitted along with panel board including component list.Type 2 SPD(3P+N) 40ka shall be installed in the incomer. 20X10MM Separate Aluminium Earth bus bar should be installed. 63amp panel board having 63A Amp 16KA 4P MCCB TMR based release with adjustable overload ,Icu=100percentIcs as incommer, 100 amp electrolyte cu bus ba-1 Set, 63A Amp TPN RCCB 300mA- 1 No,25A Amp DP RCCB 30mA- 2 No,6-32A DP MCB 10ka, c series -2 No as Outgoing with ampere meter, voltmeter, toggler switch,three nos led indicator,Drum insulator,transparent isolation glass,danger Board and Rubber Mat as per the direction of site engineer in charge (make of mccb :-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ABB Formula) Make of MCB-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB200(Lift Panel) |
| 134 | DBs Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB ITUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years. 4 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door(but with out MCB/ RCCB/ Isolator)(For LDB,PDB and UPS DB) Warranty on DB is 3 years |
| 135 | 6 Way(8+18) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door(but with out MCB/ RCCB/ Isolator)(FOR LDB) Warranty on DB is 3 years |
| 136 | 8 Way(4+24) Way TPN MCB DD DB Vertical Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 250A bus bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door(but with out MCB/ RCCB/ Isolator)(Floor DB) |
| 137 | 6 Way(4+18) Way TPN MCB DD DB Vertical Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 160A bus bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door(but with out MCB/ RCCB/ Isolator)(UPS DB) |
| 138 | Supply and fixing of 8 way DD single pole and neutral sheet steel MCB distribution board on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB ITUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years |
| 139 | Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 240 volts, MCB . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 year. |
| 140 | Supplying and fixing 63Amps 4P 415 volts MCB, C series,10KA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.Warranty on MCB is 1 year. |
| 141 | Supplying and fixing 63Amps 4P 415 volts RCCB 30 mA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The RCCB should be Replacement Warranty will be 1 year. |
| 142 | Supplying and fixing 40 Amps 4P 415 volts MCB , C series,10KA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..Warranty on MCB is 1 year. |
| 143 | Supplying and fixing 40Amps 4P 415 volts RCCB 30 mA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge..The RCCB should be Replacement Warranty will be 1 year. |
| 144 | Supplying and fixing 63Amps 3P 415 volts MCB, C series,10KA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. |
| 145 | Supplying and fixing 40Amps 3P 415 volts MCB, C series,10KA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. |
| 146 | Supplying and fixing 32 Amps DP 240 volts MCB , C series,10KA Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB FB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. |
| 147 | Supplying and fixing 160Amps,16KA 4P 415 volts MCCB thermal based, Ics=100percentIcu Make-LEGRAND-DPX3 / Siemens-3VA/ Schneider- CVS/ABB FORMULA in the existing VTPN DB complete with connections as per direction of Engg.-in-Charge. |
| 148 | Supplying and fixing 100Amps16KA 4P 415 volts MCCB thermal based, Ics=100percentIcu Make-LEGRAND-DPX3 / Siemens-3VA/ Schneider- CVS/ABB FORMULA in the existing VTPN DB complete with connections as per direction of Engg.-in-Charge. |
| 149 | Fitting & Fixtures Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover. Make-Schneider (Zencelo)/ legrand( ( Myrius) /Panasonic (vision) as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 150 | Supplying, installation, testing and commssioning of 1200 mm sweep Copper wound BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery more than equal to 215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix/Bajaj Turbo 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.(fan Regulator compatible) |
| 151 | S/F. of 5 Step modular electronic Fan regulator of Schneider ( Zencelo ) / legrand ( Myrius) / Panasonic (vision) make. |
| 152 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 153 | Supplying, installation, of exhaust fan of heavy duty 250 mm sweep 900 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 154 | S/F of 400mm sweep wall mounted fan. (Make- Havells/Crompton/Usha/Orient/Bajaj) |
| 155 | S/F of Street light- 120W,120 lm/w efficacy ,IP PC lens, IK 08 new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic cover(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) (5Years Warranty) |
| 156 | S/F of Street light- 90W,120 lm/w efficacy ,IP PC Lens,IK 08 new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic cover(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) (5Years Warranty) |
| 157 | SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 158 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10percent, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 159 | Supplying and fixing of Energy efficient Recess /Surface mounted square/round shaped LED luminaire made up of CRCA powder coated sheet steel of 2x2 25W (595mmx595mmx70mm) and (130 lm/ wt) with diffusers for better light transmission and pure effect with High luminous flux LEDs for better light output, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10percent,internal surge protection of 3 KV, complete with Non integrated isolated electronic driver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 at50,000 burning hrs (5years warranty)supply .as required as per direction of Engg.-in-Charge (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) . The luminaire must be Replacement Warranty will be 5 years. |
| 160 | SITC of 4 pair Cat6 23 awg U/UTP LSZH Cable in the existing surface/ recessed steel/ PVC conduit as required: The 4 pair Unshielded Twisted Pair cable shall be UL Listed,exceeds the requirements of ANSI/TIA-568-C.2 and ISO/IEC 11801 Class E , 4 twisted pairs separated by internal PE Cross Separator. Full separator. Half shall not be accepted. Rip Cord is must,Insertion Loss of 32.8 db/100m at 250 MHz ,Cable should support operating temperature from -20° to +70°C Cable support Conductor Resistance less than equal 9.38 new/100m Max., Cable support Delay Skew: less than 45 ns/100m, Operating Voltage: 72V , Impedance: 100 ± 15 at100 MHz. and Propagation Delay at 250 MHz : 536 ns/100m, ETL Verified 4 connector channel performance up to 700 MHz , RoHS Compliant. Make: Systimax, Legrand, Panduit |
| 161 | SITC of 6 core Single mode OS2 Unitube Armoured Optical fiber cable through existing conduit: The Fiber should be OS2 Single Mode Optical Fiber Cable of Size 9/125m. Outdoor Corrugated Steel tape Central loose tube. ( Standard Approved: ISO 11801 2nd edition/ EN 50173-1:2002 / IEC 60794-1/IEC 60793-2-50 class B1.3 / EN 60793-2-50: class B1.3 / ITU Recommendation G.652.D - the oder ITU designations A, B and C are also fulfilled / OS1/ISO/IEC 24702:2006, cat. OS2; also OS1 requirements are fulfilled/IEEE 802.3 - 2002 incl. 802.3ae ) Jacket. Make: Systimax, Legrand, Panduit |
| 162 | SITC of Cat6 I/O with Dual Face plate: The Outlet shall meet or exceed requirement as per ANSI/TIA 568C.2,ISO/IEC 11801, & EN50173. The information outlet NEXT, PSNEXT, FEXT, ELFEXT, PSELFEXT and return loss should be verified for CAT6 at 250Mhz & CAT6A at 500Mhz. The information outlet connector shall be of gold/nickel, thickness of gold more than 0.8 m. The connectors shall be compatible as per IEEE 802.3af standard for POE application. The PVC material of Face plate should complie ABS /UL94-V-O certified. Make: Systimax, Legrand, Panduit |
| 163 | Supply and Laying of 20mm HMS FRLS pvc conduit in complete as per the direction of engineer incharge.Make-AKG/BEC/Precision/Norpak/ Anchor/Kinjal |
| 164 | Supply and Laying of 25mm HMS FRLS pvc conduit in complete as per the direction of engineer incharge. Make-AKG/BEC/Precision/ Norpak/ Anchor/Kinjal |
| 165 | SITC of 24 Port Layer 2 PoE+ Switch having 24 x 10/100/1000 Mbps Ethernet PoE+ ports with 4 x 1/10Gig SFP+ ports ,1 x RJ45 port console port ,Switching Capacity 128 Gbps , Throughput 96 Mpps ,MAC Address 16k , Switch should support IEEE 802.3af (15.4W) & IEEE 802.3at (30W). Total PoE power: 370W or above , Switch should support DHCP server/relay/client, DHCP snooping/option82 , Switch should support Console, Telnet, SSH v1/2, HTTP, HTTPS, SNMP v1/v2/v3, RMON , TFTP, FTP, SFTP, NTP, ZTP, SPAN, RSPAN,Switch should support support ICMPv6, DHCPv6, ACLv6 ,IPV6 Telnet ,Temperature 0°C -50°C ,Power Supply AC: 100-240V. Make: Digisol, Cisco, HP |
| 166 | SITC of Rack mount Draw Type Loaded 6 port LIU available in Standard 19 inch ,Dimensions (mm) : 430 X 220 X 1U , Cold Rolled Steel as Raw Material , Consist of Top Cover and Bottom Panel , Easy to Assemble and Dissemble , Three Types of Input Holes Cable Entry Through Water Proof Cable Clamp , 12 Duplex SC or LC Adapter Interface , Splice 24 Fibers at Most with 1 Tray ,Adaptor, SM, Duplex SC, PC Type ,Pigtail, Support the TIA/EIA Telecommunication Wiring Standards. Compact Design , Telcordia GR-326-Core . Make: Systimax, Legrand, Panduit |
| 167 | SITC of 1G-LX/LH SFP transceiver module,SMF, 1310nm, 9/125 um Single mode Fiber Type up to 20 KM. Make: Cisco, Digisol, Netgear |
| 168 | SITC of OFC Patch Cor, SM (OS2), Duplex LC-SC, LC-LC PC Type, 3M, LSZH Fiber Optic Single Mode OS2 Patch Cords are offered in LSZH Jackets with Corning Fiber,Insertion Loss : less than= 0.2 db, Max 0.3db/MTRJ: Max 0.5db Return Loss : PCmore than= 45db, UPCmore than=50db, APCmore than=60db. Make: Systimax, Legrand, Panduit |
| 169 | SITC of 9U/500D Wall Mount Rack with Accessories: The rack size should be 600W x 500D, Front frame integrated with top, bottom, front and two side panels for better rigidity and strength, Front Glass Door with Lock loaded, Compliance with standards shall be UL 2416., DIN 41494, IEC EN 60529, IEC EN 62262 , IEC EN 60068-2-11 , ISO 9001:2008 including Power Distribution Unit (06/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Lengt), 1 cooling Fan(230V AC - 90 CFM, dB 42), 2nos 1U Metal Cable manager with Plastic cable loops and H/W screw. Make:Valrack, Rittal, Legrand |
| 170 | SITC of 24U 600/650D UL Listed Floor mount Rack with Front perforated door with 3 point lock, Rear mesh door with Cam lock and 3inch Castor Wheel included with 2 no 6/16 Amp Indian-Standard - 06 Socket - Single Pole / Screw Mountable / 16 Amp MCB / Alternating Current - 16 Amp 3 Pin Plug with Power Cable 2.5 sq.mm 3 meter Length, 4nos 1U Metal Cable manager with Plastic cable loops, 2nos CFM FAN set, 1no Monitor Tray - Ventilation - 495W - 375D and H/W screw920sets). Make:Valrack, Rittal, Legrand |
| 171 | FIRE EXTINGUISHERS Supply & Installation of 20 gm Portable Aerosol based Automatic Fire Extinguisher (Coverage: 0.2 m3), EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction of Engineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Genefire/Stat-x/Equivalent |
| 172 | Supply & Installation of 50 gm aerosol based Manual Fire Extinguisher (Duration:10-20 sec) , EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction ofEngineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 5 years. Make-Pyrogen/Genefire/Stat-x/Equivalent |
| 173 | CABLES Supply of 300 sq.mm 3 & 1/2 core XLPE Al.Armoured Cable of ISI marked.(Make -Polycab/Havells /KEI/RR Kable/Finolex/Gloster) |
| 174 | Supply of 95 sq.mm 3 & 1/2 core XLPE Al.Armoured Cable of ISI marked.(Make -Polycab/Havells /KEI/RR Kable/Finolex/Gloster) |
| 175 | Supply of 16 sq.mm 4 core XLPE Al. Armoured Cable of ISI marked.(Make -Polycab/Havells /KEI/RR Kable/Finolex/Gloster) |
| 176 | HOT DIPP GALVANIZED(GC) AS PER EN-ISO-1461 ,hot dip galvanized Perforated CABLE TRAYS with internal dimensions of size 60mm(H) x 200mm(W),of reputed make ISI marked as approved .The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications.(With all accessories,bend, cover,supporter) WITH REQUIRED SIZED JUNCTION BOX ,COVER CONNECTOR as required as per direction of Engg.-in-Charge. Make-OBO-Profab/Neidax |
| 177 | Supply of 75 mm dia HDPE Pipe . |
| 178 | Laying and fixing of one number of PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size exceeding 120 sq.mm but not exceeding 400 sq.mm direct in ground including excavation, sand cushing, protective covering and refilling the trench etc. as required. |
| 179 | Laying and fixing of one number of PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size exceeding 120 sq.mm but not exceeding 400 sq.mm on surface as required. |
| 180 | Laying and fixing of one number of PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm on surface as required. |
| 181 | Laying and fixing of one number of PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm on surface as required. |
| 182 | Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium cable of 1.1 KV as required. (3.5C x 300 sq.mm) |
| 183 | Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium cable of 1.1 KV as required. (3.5C x 95 sq.mm) |
| 184 | Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium cable of 1.1 KV as required. (4C x 16 sq.mm) |
| 185 | S/IT/C of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 186 | Supplying and laying 25 mm x 5 mm GI earth strip ISI marked on surface or in recess for connection etc as required. |
| 187 | PH WORK Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. 20mm dia C-PVC pipe (SDR-11) Ground Floor |
| 188 | First Floor |
| 189 | Second Floor |
| 190 | 25mm dia C-PVC pipe (SDR-11) Ground Floor |
| 191 | First Floor |
| 192 | Second Floor |
| 193 | 32mm dia C-PVC pipe (SDR-11) Ground Floor |
| 194 | First Floor |
| 195 | Second Floor |
| 196 | 40 mm dia C-PVC pipe (SDR-11)(Top Floor) First Floor |
| 197 | Second Floor |
| 198 | 50 mm dia C-PVC pipe (SDR-11)(Top Floor) |
| 199 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. 15mm dia CP angle stop cock (Jaquar)CON-CHR-059KN |
| 200 | 15mm dia CP two way bib cock (Jaquar)CON-041KN |
| 201 | 15mm dia CP Bib cock (Con-CHR-047KN Jaquar make) |
| 202 | 15mm dia CP Pillar cock (Con-CHR-011KN Jaquar make) |
| 203 | 15mm dia CP Health faucet (Con-ALD-MCH-573 Jaquar make) |
| 204 | 25mm dia brass full way valve (Shakti make) |
| 205 | 32mm dia brass full way valve (Shakti make) |
| 206 | 40mm dia brass full way valve (Shakti make) |
| 207 | 50mm dia brass full way valve (Shakti make) |
| 208 | 15mm CP Extension piece |
| 209 | 125mm CP grating |
| 210 | 15mm size C.P. flange |
| 211 | Supplying all materials , labour, T&P and fixing rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS:12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 5.40 mtr. lengthx0.25 mtr width KB brickwork in cement mortar (1:6) of 0.46m height in staging and 0.13mtr thick circular protection wall of 0.46mtr height to support the tank,12mm thick cement plaster in cement mortar (1:6) over brick work, RCC slab of size 1.60mX1.60m and 0.10m thick ,RCC beam of 0.25mx0.30m and 3.40m average length in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips and required steel reinforcement including centering and shuttering,watering,curing ,cost of all materials,conveyance of all materials to worksite , payment of royalty, all taxes etc.all complete as per approved drawing , P.H. specification and direction of Engineer-in-charge 2000 liters capacity PVC water storage tank roof of 2nd Floor |
| 212 | supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings including watering, curing, cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per direction of Engineer-in-charge. Ground Floor |
| 213 | First Floor |
| 214 | Second Floor |
| 215 | Supplying all materials , labour, T&P and cutting holes in RCC floors and roofs upto 19cm thick for passing P.V.C pipes and G.I fittings etc. , and repairing the holes after insertion of pipe etc. with cement concrete (1:2:4) including finishing complete so as to make it leak-proof as per P.H. specification and direction of Engineer-in-charge Ground Floor |
| 216 | First Floor |
| 217 | Second Floor |
| 218 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages including watering , curing , cost & conveyance of all materials to worksite, payment of royality, taxes etc all complete as per direction of the Engineer-in-charge. Ground Floor |
| 219 | First Floor |
| 220 | Second Floor |
| 221 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturers specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. 110mm U-PVC SWR Pipe (Ori Plast/Finolex/Supreme Make Type-B) |
| 222 | 75mm U-PVC SWR Pipe (Ori Plast/Finolex/Supreme Make Type-B) |
| 223 | 110mm U-PVC P Trap(Ori Plast/Finolex/Supreme Make) |
| 224 | 110mm U-PVC door bend(Ori Plast/Finolex/Supreme Make) |
| 225 | 110mm U-PVC Plain bend(Ori Plast/Finolex/Supreme Make) |
| 226 | 110mm U-PVC Cowl(Ori Plast/Finolex/Supreme Make) |
| 227 | 110mm U-PVC Plain tee(Ori Plast/Finolex/Supreme Make) |
| 228 | 110mm U-PVC Door tee(Ori Plast/Finolex/Supreme Make) |
| 229 | 110mm U-PVC Socket(Ori Plast/Finolex/Supreme Make) |
| 230 | 75mm U-PVC plain bend(Ori Plast/Finolex/Supreme Make) |
| 231 | 75mm U-PVC door bend(Ori Plast/Finolex/Supreme Make) |
| 232 | 75x75x75mm U-PVC double equal door Tee(Ori Plast/Finolex/Supreme Make) |
| 233 | 75mm U-PVC vent cowl(Ori Plast/Finolex/Supreme Make) |
| 234 | Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x30mm footrest, fixing 100mm dia HCI p or s trap (with/without 50mm dia horn) for water colset squatting pan including jointing the trap with pan in cement mortar (1:1) cutting the floor and mending good the damages , cost & conveyance of all materials to worksite, payment of royality , taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. 580mm size Orissa pan (Hindware/Parrywaremake) |
| 235 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet (European type W.C pan) with integral P or S trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in charge. European water closet with s trap plain(Hindware/Parryware/Neycer make) |
| 236 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet(European type W.C. pan)with integral p or s trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing , cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge One piece commod(Hindware)ELEMENT Cat No.92084. |
| 237 | Supplying all materials, labour T&P and and fixing 12.50 liters/10 liters capacity low level flushing cistern with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge 10 ltr. Capacity pvc L.L. cistern with 32mm. Dia CP long flush bend ( Slimline-white-Parryware make ) |
| 238 | Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered Hot and Cold with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, cost & conveyance of all materials to worksite, payment of taxes etc. all complete as perP.H specification and direction of the Engineer-in-charge 550mmx400mm W.H.basin (Hindware/Parryware/Neycer make)with 15mm dia C.P.pillar cock (Plaza make) with pedestal |
| 239 | Under Counter basin(560x450)Hindware-No.10095 |
| 240 | Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge 25mm x 600mm long CP towel rail(Jaquar)ACN-ACR-1111N |
| 241 | CP towel Ring(Jaquar)ACN-ACR-1121N |
| 242 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge CP soap holder (Jaquar)ACN-ACR-1131N |
| 243 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rail complete fixed to wooden plugs with CP screws as per specification and direction of Engineer in charge. 600 x 125mm plate glass shelf with CP guard rails(Jaquar)AKP-CHR-35771P |
| 244 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm.thick A.C. sheet or ply wood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of Engineer in charge. 600mmx450mm size B.E mirror (swivelled type) |
| 245 | Large Size mirror with Frame (18x0.90x0.90)= |
| 246 | Supplying all materials,labour,T&P and fixing Flat back lipped wall (Mini stall urinal -630mmx180mm) urinal of the following sizes including connecting the urinal with 32mm. dia pvc waste pipe 910mm. long by means of white lead mixed with chopped hemp, fixing 32mm. dia CP dome waste, 15mm. dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc. all complete as per specification and direction of the Engineer in charge.Stall Urinal - Flat Back stall type magnum urinal |
| 247 | Supplying all materials , labour, T&P and cutting holes through existing brick or laterite masonry wall for taking U-PVC pipes and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge |
| 248 | Supplying all materials , labour, T&P and cutting of RCC chajja for taking HCI or U-PVC pipe and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge |
| 249 | Supplying all materials labour & laying the waterproofing material of Dr. fixit torch shield P3160(3mm) with its primer 2 coats or equivalent water proofing materials after drying cleaning the concrete surface over the concrete floor/roof/balcony/ sunken and dado upto16inch in wall including cleaning, applying and mending as per specification including cost, conveyance, taxes, royalities of all materials to worksite etc. all complete as per the direction of the Engineer- in- charge. Ground Floor |
| 250 | First Floor |
| 251 | Second Floor |
| 252 | Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge Ground Floor |
| 253 | First Floor |
| 254 | Second Floor |
| 255 | Supplying all materials, labour, T&P and providing and fixing ceramic tiles in floors, treads or steps and landing on 25mm thick bed of cement mortar (1:1) ( 1 cement : 1 sand ) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge ( ceramic floor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 of size 40cmx40cm special printed series to be pre-approved by the Engineer-in-charge ) Ceramic tile 60cmx60cm(Kajaria/Somany/Johnson) Ground Floor |
| 256 | First Floor |
| 257 | Second Floor |
| 258 | Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:4) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. Ground Floor |
| 259 | First Floor |
| 260 | Second Floor |
| 261 | Supplying all materials, labour, T&P and providing and fixing porcelain glazed tiles in dado skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge( ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm conforming to IS 13753 of size 25cmx33cm special plain / printed series to be pre-approved by the Engineer-in-charge ) glazed tile 45cmx30cm (Kajaria/Somany/Johnson) Ground Floor |
| 262 | Granite Tiles 20 mm thick = |
| 263 | First Floor |
| 264 | Granite Tiles 20 mm thick = |
| 265 | Second Floor |
| 266 | Granite Tiles 20 mm thick = |
| 267 | Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centres standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. |
| 268 | Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge |
| 269 | Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) pure chill 120 PSS UV of size 750 x 570 x 1350mm hight with water storage capacity 120 liters along with 3 noa of faucets 2 for cold water and 1 for normal water including a flow of 1.5 ltr per munite etc all complete as per approved drawing , specification and direction of the Engineer in charge Aqua guard pure Chill 120 PSS UV |
| 270 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class- 3 (0.60mpa ) including jointing with supply of approved solvent cement by non-heat application method/as per manufactures specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge 110mm dia u-pvc pipe alround concrete |
| 271 | 160mm dia u-pvc pipe alround concrete |
| 272 | Supplying all materials ,labour ,T&P and constructing gully trap chamber of inside size 250mmx250mm with 8cm thick RCC precast cover slab in cement concrete (1:2:4) mix using 12mm size crusher broken HG chips, foundation concrete (1:4:8) using 40mm size crusher broken HG metal on bed and around trap, KB brick work in cement mortar (1:6) in foundation and plinth and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap, 150mmX150mm size CI grating etc.all complete as per drawing, specification and direction of Engineer-in-charge |
| 273 | Supplying all materials ,labour ,T&P and constructing Inspection Chamber of inside size 760mmx760mmx460mm with cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips, 12mm thick cement plaster (1:3) with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc.all complete as per approved drawing, P.H specification and direction of Engineer-in-charge Inside size 76cmx76cmx46cm with 18inch dia RCC MH cover |
| 274 | Supplying all materials labor T&P and constructing MH chamber of sizes earth work in excavation in all kinds of soil CC(1:1:8) with black granite chips size 46mm brick work with K.B. brick having crossing strength not less than 75 Kg /CM2 to 90 Kg/CM2s in CM(1:6)12mm C.P(1:8) inside MH chamber over benching with cement slush pointing (1:3)outside the MH chamber providing painting MS or CI step iron RCC(roof of slab with CC(1:2:4)with black granite chips size 12mm bending binding tying the grills placing of the reinforcement providing RCC color of required size refilling the cavity around the MH chamber with excavated earth including channeling the bed of MH etc all complete as per PH specification. MH size 0.91m x 0.91 m with 0.45 m (18 inch dia RCC Cover ) |
| 275 | Supplying all materials labour T&P and constructing 1.40m dia x 2.00 m deep soak way pit with dry brick having crossing strength not less than 75Kg/CM2 to 99Kg/CM2 in CM(1:6) for the remaining 0.4572mm height of wall at top CC(1:3)inside and outside inside fill with dry brick khoa size 38mm ,CM thick RCC perforated slab to a height of 1.9012m from bottom covered by means of 50mmthick RCC wall cover in pieces filled with iron plugs including earth work in excavation refilling of cavity around the pit and painting the iron works complete as per PHD design and specification including carriage of all materials to site. |
| 276 | 1 nos 100 Users septic tank (Size-8.00m X 2.70m X 2.55m) Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge. |
| 277 | Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge with 1st extra lift of 1.50 m over initial laft. |
| 278 | Supplying all materials labor T&P filling sand in foundation and plinth with well watered and rammed etc all complete as per direction of Engineer-in-charge.. |
| 279 | Supplying all materials, labor T&P providing CC (1:3:6) with 4 cm HG metal including watering curing lead of all materials to site etc. complete. |
| 280 | Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge. |
| 281 | Supplying all materials, labour, T&P and providing cement concrete (1:1½:3) with 12mm size crusher broken hard black granite chips for RCC works including hoisting, laying, watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per PWD specification and direction of the Engineer in charge.. |
| 282 | Supplying all materials, labour, T&P and providing steel reinforcement of Fe-415 /Fe-500 grade for RCC work including cutting,bending,binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge,cost of steel, conveyance of all materials to worksite, payment of royalty,all taxes etc all complete as per PWD specification and direction of the Engineer-in-charge. |
| 283 | Supplying all materials, labour, T&P and providing rigid & smooth centering and shuttering for RCC works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per specification and direction of the Engineer-in-charge RCC floor, roof slab chhaja up to 4.430 m height |
| 284 | Supplying all materials.labour.T&P and providing brick work in foundation and plinth with 23cm x11cm x 8cm size Fly Ash bricks having curshing strength not less than 75 kg/sqcm with dimensional tolerance+ 8percent in cement mortar ( 1:6 ) including watering,curing,cost of all materials,conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer in charge. |
| 285 | Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:3) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 286 | Supplying all materials,labour,T&P and providing 16mm thick cement plaster(1:6) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 287 | Supplying all materials, labour, T&P and providing cement punning including watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per specification and direction of the Engineer-in-charge |
| 288 | Supplying all labor T&P & filling foundation and plinth with excavated materials well watered & rammed etc. all complete as per direction of EIC. |
| 289 | 1 no 16,000 ltr capacity R.C.C. Under ground sump Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge. |
| 290 | Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge with 1st extra lift of 1.50 m over initial laft. |
| 291 | Supplying all materials labour T&P filling sand in foundation and plinth with well watered and rammed etc. all complate. As per direction of ELC. |
| 292 | Supplying all materials, labor T&P providing CC (1:3:6) with 4 cm HG metal including watering curing lead of all materials to site etc. complete. |
| 293 | Providing C.C. (1:1½:3) with 12mm size hard granite chips of RCC work including hoisting and laying and curing with lead of all materials to site. |
| 294 | Supplying all materials, T&P and providing MS reinforcement for RCC work including cutting, bending, binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauges. |
| 295 | Rigid & smooth centering & sheltering for RCC work including falls work & dismantling than after casting including cost of materials in ground floor. RCC floor, roof slab chhaja up to 4.430 m height |
| 296 | Supplying all materials, labour, T&P and providing 6mm thick cement plaster (1:4) to RCC surfaces finished smooth including closed deep chipping and slurry tratment including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge |
| 297 | Supplying all materials labour T&P and providing cement punning including watering curing and conveyance of all materials to site. In side |
| 298 | Supplying all labor T&P & filling foundation and plinth with excavated materials well watered & rammed etc. all complete as per direction of EIC. |
| 299 | Construction of 1 nos production wells including scientific source finding through consolidated and unconsolidated rock with down the hammer drilling rig or combination rig with PVC pipe and installation of submersible pump set with all acessories Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with down the hole hammer drilling rig or combination rig as required to suit the site condition as per the direction of the Engineer in charge including use of own rig with its accessories, tools and plant and consumables etc for lowering of 200mm/150mm dia G.I/P.V.C/M.S casing pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (G.I/ P.V.C/ M.S casing pipes if required to prevent collapse of overburden is to be provided by the contractor including lowering and withdrawing after completion of the tube well), 200mm dia to 400mm dia in overburden portion including packing of gravel supplied by the contractor for 400mm dia bore only Drilling of 200mm dia bore 00 mtr to 30mtr 1 x 30.00 mtr = |
| 300 | 31 mtr to 45mtr 1 x 15.00 mtr = |
| 301 | Drilling of 150mm dia bore 46 mtr to above 1 x 150.00 mtr = |
| 302 | Lowering the following size of G.I/P.V.C/M.S housing pipes with or without slotted pipes as per the necessity from ground level up to 45.00m depth and fitted and fixed up in perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plant etc all complete and keeping the top of casing pipe threaded including plugging tube wells to prevent entry of foreign materials. Lowering of 200mm dia P.V.C casing pipes 00 mtr to 45 mtrs |
| 303 | Supplying polyvinyl chloride pipes as per ASTM-D-1785-89 having threads in accordance with DIN 2999 part-1/DIN-42225 part-II specification length of pipe (laying length) will be 3 mtrs. The pipes shall be supplied with both external and threaded with free socket. The pipe having external thread at one end i.e female and or belled end. The female end having internal thread is to be belled in order to accept the male end while jointing pipes with a bore threading shall be provided with a greave at the roof of the male thread accomodate flexible PVC/Rubber O ring to make the joint water tight colour of the pipe shall be blue. The name of the manufacture along with batch No class of pipe shall be stranded legibly of each pipe length. 200mm dia PVC (sch-80) pipe |
| 304 | Supplying all materials, labour, T&P and providing and providing sanitary sealing by cement concrete grouting of annular space around GI/PVC/MS housing pipe upto 5m below ground level (as per drawing) to plug the bore hole excluding cost of cement all complete as per direction of the Engineer in charge. Minimum one metre of casing pipe to be inserted in the bore into the rock at the bottom to ensure sanitary sealing (excluding cost of cement which will be supplied directly by the department) |
| 305 | Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge By DTH Rig |
| 306 | Supplying all materials, equipment, labour & conducting reconnaissance survey, integrated Hydrological and Geophysical (Electrical Resistivity Method) survey & selection of potential source for exploration of Ground Water including selection and recommendation of site for drilling wells in selected locations in any part of Orissa under the following Geological formation: Rocky terrain with boulder formation for 300m depth |
| 307 | Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge (Texmo/Crompton Greaves/Kirloskar make) 2 H.P. Single phase/ three phase 3 stage head renge of 20 to 35 mtr with discharge capasity 145 to 110 L.P.M With outlet dia 25 mm (keeping 100percent standby) |
| 308 | DOL Control panel |
| 309 | 40mm dia steel short piece |
| 310 | Well cap |
| 311 | 50mm size CI bracket |
| 312 | 2.50sqmm flat cable |
| 313 | 20mm dia rigid UPVC pipes |
| 314 | Steel rope with cover |
| 315 | Labour charges for lowering including transportation |
| 316 | Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor HDPE pipes and pipe fittings conforming to IS: 4984/2000 (10kgf/sqcm) of the following nominal bore with clamps and jointing by Fusion welding method including testing, making good the wall, ceiling and floor all complete as per specification and direction of the Engineer in charge 32mm HDPE pipes (Finolex/Supreme make) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail