| 1 | Dismantling wall and ceiling boards (fibre, pulp, insulation , etc.) or insulation boards/ slabs/ blankets any thikness including cover fillets. |
| 2 | Dismantling timber scantling 40 sq cm and over in section ,in any position etc complete all as specified & directed |
| 3 | S & F anodised aluminium frame for doors, windows, ventilators with one or more rebatesincluding joining cleates for fixing etc. complete all as specified. |
| 4 | M&L for 4mm thick non asbestos fiber cement building boards as in false ceiling fixed to aluminium snap grid frame work size 605 x 605mm with using 36.5mm x 23.5mm x 1.5mm thick main tee, 23.5x23.5x1.28mm cross tee and 25x25x1.5mm angles fixed to perimeter of wall including necessary supporting hanger with 4 mm dia GI wire and J bolts washer nuts for securing frame work to ceiling suspended @120 cm c/c both ways, complete all as specified and directed. |
| 5 | S&F PVC wall panelling made up of PVC hollow panels 25/30cm in width and 10mm thickness interlocking pattern of approved shade and design fixed to wall or ceiling all as specified and directed. |
| 6 | S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing. |
| 7 | Taking down chowkat or frames with shutters (without taking off shutters from the frame n.exc 1.5 sqm each complete all as specified. |
| 8 | Taking down chowkats or frames including shutters (without taking off shutters from the frame) exc. 1.5 Sqm but n exc 4.0 sqm each, complete all as specified & directed. |
| 9 | S & F Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified. |
| 10 | S & F anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessar joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aliminium snap beading screws etc. coplete all as specified |
| 11 | Supply and fixing 4.8 mm thick ordianary quality sheet glass n.exe 0.5 sqm in each pane of glazing with oil putty /beading etc all as specified and directed by Engineer-in-Charge. |
| 12 | Dismantling of roof sheeting any gauge thickness including Nainital or similar pattern roof coverings, complete all as specified and as directed by Engineer-in-charge. |
| 13 | S&F plain galvanised, 0.63mm thick mild steel sheeting , in ridges, hips, valley gutters, drip and straight flashings(length and girth as fixed) with grade of zinc coating 275Gm / sqm |
| 14 | S&F for 0.63mm thick galvanised corrugated mild steel sheeting with two coggugations side lap fixed with L-type or J-type or cranked hook bolts in lieu of screws in roofs walls etc with grade of Zine coating 120 Gm / Sqm,complete all as specified and as directed by Engineer-in-Charge. |
| 15 | M&L for preparing of Old painted surfaces of steel or iron surfaces of any description, over 10 cm width or girth and applying one coat of synthetic enamel paint. |
| 16 | M&L for preparation of new or previously untreated steel or iron surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red-oxide primer. |
| 17 | S&F Door closer hydraulically regulated Aluminium (Die cast) body design No-3 universal type, suitable for door shutter of 851 to 1000mm in width and of weight between 61 to 80 Kg and fixed complete all as specified and directed by Engineer-in-Charge . |
| 18 | Demolition of cement concrete any description (unreinforced) in ground floors and pavings not exceeding 15 cm in thickness all as specified and directed by Engineer-in-Charge. |
| 19 | M&L 75mm thick, plain cement concrete 1:3:6, type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection laid in alternate bays finished even and smooth without using extra cement incl form work complete all as specified and directed by Engineer-in-Charge. |
| 20 | Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises outside Cantt area all as specified and directed by Engineer-in-Charge. |
| 21 | Vitrified light shade ceremic tiles 600mmx600mmx 10mm thick (Square/rectangular) polished in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15mm thick screed bed in cement mortar 1:6, complete all as specified & directed. |
| 22 | 25 mm thick plain cement concrete 1:2:4 type B-0 ( using 12.50 mm graded stone aggregate) as in sub bases of floors rough finished . |
| 23 | Taking down old point wiring complete for light/fan/socket(5/15 Amps) bell point etc complete with all light fittings accessories, such as switch sockets 5/15 Amps ceiling rose etc including making good to the disturbed surface to match with the existing complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
| 24 | Taking down old point wiring complete for light/fan/socket(5/15 Amps) bell point etc complete with all light fittings accessories, such as switch sockets 5/15 Amps ceiling rose etc including making good to the disturbed surface to match with the existing complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |