Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavatedearth lead upto 50 m and for all lift, as directed by Engineer-in-charge.. :All kinds of soil. |
| 2 | Extra for every additional lift of 1.5 m or part thereof in excavation /banking excavated or stacked materials. All kinds of soil |
| 3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. |
| 4 | Supplying and filling in plinth with Jamuna sand under floors, including watering, ramming, consolidating and dressing complete. |
| 5 | Treatment of soil under existing floors using chemicalemulsion @ one litre per hole, 300 mm apart including drilling12 mm diameter holes and plugging with cement mortar 1 :2(1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-lll) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 7 | 1:4:8 (1 Cement : 4 coarse sand derived fromnatural sources : 8 graded stone aggregate 40mm nominal size derived from natural sources) |
| 8 | Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-lll) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived fromnatural sources). |
| 9 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. |
| 10 | 1:2:4 (1 cement : 2 coarse sand derived fromnatural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources) |
| 11 | 1:5:10 (1 cement : 5 coarse sand (zone-lll) derived fromnatural sources : 10 graded stone aggregate 40 mmnominal size derived from natural sources) |
| 12 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-lIll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 13 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. All works upto plinth level |
| 14 | Providing and laying in position ready mixed or site batched design mixcement concrete for reinforced cement concrete work; using coarseaggregate and fine aggregate derived from natural sources, PortlandPozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the followinggrades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified mininum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement:All works upto plinth level:Concrete of M30 grade with minimum cementcontent of 350 kg /cum |
| 15 | Concrete of M30 grade with minimum cementcontent of 350 kg /cum for columns, pillars piers etc. |
| 16 | Concrete of M25 grade with minimum cementcontent of 330 kg /cum in lintel beams and girders etc. |
| 17 | Add for using extra cement in the items of design mix over and above the specified cement content therein. |
| 18 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 19 | Foundations, footings, bases of columns, etc. for mass concrete |
| 20 | Walls (any thickness) including attached pilasters,butteresses, plinth and string courses etc. |
| 21 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 22 | Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 23 | Suspended floors, roofs, landings, balconies and access platform |
| 24 | Stairs, (excluding landings) except spiral-staircases |
| 25 | Weather shade, Chajjas, corbels etc., including edges |
| 26 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars |
| 27 | Providing and filling in position, blown bitumen in expansion joints |
| 28 | Providing and fixing sheet covering over expansion joints with iron screws as per design.: Aluminium fluted strips 3.15 mm thick. 200 mm wide |
| 29 | Brick work with bricks of Ist class in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 30 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 31 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 32 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) |
| 33 | Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. |
| 34 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters : 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 35 | Providing and fixing ISI marked Bright finished M.S. fitting for door windows. |
| 36 | 250x16x5 mm sliding door bolts |
| 37 | 250x10 mm Tower bolt |
| 38 | 150x10 mm Tower bolt |
| 39 | 125 mm handles |
| 40 | 100 mm handles |
| 41 | hanging floor door stopper, Twin rubber stopper |
| 42 | 200 Casement stays (straight peg type) with necessary screws etc. complete, weighing not less than 120 gms |
| 43 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 44 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape,colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frameto finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash &mullion (if required) shall be mitred cut and fusion welded/mechanicallyjointed duly sealed at all corners, including drilling of holes for fixinghardware and drainage of water etc. After fixing frame the gap betweenframe and adjacent finished wall shall be filled with weather proof siliconsealant over backer rod of approved size and quality, all complete asper approved drawing conforming to CPWD specification & direction ofEngineer-in-Charge. Section of steel reinforcement and cross sectionsof uPVC profiles to be as per design approved by Engineer-in-Charge. |
| 45 | Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. |
| 46 | Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for :(i) Sites with basic wind speed > 45 m/sec as per IS 875 — Part 3(ii) Sites with structure height more than 20m for all wind speeds |
| 47 | Three track three panels sliding door with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, zinc alloy (zamak) powder coated handle on two panels along with multi-point locking system, adjustable nylon rollers with SS 304 body.Using R3 series with frame (98 mm & above) x(40 mm & above) & both glazed and fly screensash (30 mm & above) x (74 mm & above).(Height upto 2.5 metre). |
| 48 | Providing and fixing glazing in uPVC/aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) |
| 49 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.:Upto 5 mm depth and 5 mm width |
| 50 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete: Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides |
| 51 | Providing and fixing M.S. Tubular frames for Doors with rectangular/ L-Type sections, made of 2.0 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer: Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 52 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding |
| 53 | Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. With 12 mm mild steel U beading |
| 54 | Steel work in built up tubular ( round, square or rectanglar hollow tubes etc. ) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes |
| 55 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 56 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube |
| 57 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 5.5 mm thick glass panes |
| 58 | Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. |
| 59 | The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi- etallic contacts, all complete to perform as per Specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. |
| 60 | The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured. |
| 61 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. |
| 62 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), including grouting the joints with white cement and matching pigments etc., complete. |
| 63 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make,in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 64 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge:Polished Granite stone slab of colour Black, Cherry/RubyRed or equivalent |
| 65 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. |
| 66 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate |
| 67 | Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick |
| 68 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick |
| 69 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 70 | Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of : |
| 71 | (i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course. Joints sealed and grouted with cement slurry mixed with water proofing compound. |
| 72 | (ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions.(iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer. Using rough kota stone. |
| 73 | Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge : Using rough kota stone. |
| 74 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. |
| 75 | (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarsesand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.(iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. |
| 76 | (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm). |
| 77 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. |
| 78 | The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick |
| 79 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :In 75x75 mm deep chase |
| 80 | Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) |
| 81 | Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 2 mm thick corrugated (2.5\\" or 4.2\\" or 6\\") or step-down (2\\" or 3\\" or 6\\" ) as specified |
| 82 | Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J. or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. 0.63 mm thick with zinc coating not less than 275 gm/m² |
| 83 | Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3 mm size, bolts, nuts and washers etc.,including making necessary connections with rain water pipes complete:0.63 mm thick with zinc coating not less than 275 gm/sqm |
| 84 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, |
| 85 | 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. |
| 86 | Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. |
| 87 | 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit. |
| 88 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand) |
| 89 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand) |
| 90 | 20 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) |
| 91 | 12mm C.P. finished with a floating coat of neat cement in cement mortar 1:4( 1 cement : 4 fine sand) |
| 92 | 6 mm cement plaster 1:3 (1 cement: 3 fine sand) |
| 93 | Applying priming coat : With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood |
| 94 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 95 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 96 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 97 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 98 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. |
| 99 | Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). |
| 100 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting nd aaking mood ge alltsh nwd ooars flherevewr equiredr:White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests |
| 101 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 102 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I.brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid |
| 103 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 1500x450 mm |
| 104 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.:110 mm diameter |
| 105 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms |
| 106 | P/F Upvc nahani trap 110x110mm dia |
| 107 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. |
| 108 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) andmaking good the wall etc. complete:110 mm |
| 109 | P/F Upvc terminal guard 110 mm dia |
| 110 | Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 15 mm nominal bore with 45 cm length |
| 111 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 110 mm bend |
| 112 | P/F Upvc door bend 110 mm dia. |
| 113 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 32 mm dia |
| 114 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming toIS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 110x110x110 mm tee |
| 115 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 116 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern |
| 117 | Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade |
| 118 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 225 mm |
| 119 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm |
| 120 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter |
| 121 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 122 | 110 mm bend |
| 123 | 110 mm Shoe |
| 124 | 110x110x110 mm tee |
| 125 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1m x1 _m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 126 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm |
| 127 | Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : 15 mm dia nominal bore |
| 128 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. |
| 129 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. |
| 130 | 20 mm dia |
| 131 | 25 mm dia |
| 132 | 32 mm dia |
| 133 | 20 mm dia nominal bore |
| 134 | 25 mm dia nominal bore |
| 135 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 32 mm dia nominal bore |
| 136 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 137 | 20mm nominal bore |
| 138 | 25 mm nominal bore |
| 139 | 32 mm nominal bore |
| 140 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore |
| 141 | Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : 25 mm nominal bore |
| 142 | Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
| 143 | Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation oncrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
| 144 | Providing and filling sand of grading zone V or coarser grade, allround the CPVC pipes in external work : |
| 145 | 20 mm diameter pipe |
| 146 | 25 mm diameter pipe |
| 147 | 32 mm diameter pipe |
| 148 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 149 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore |
| 150 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore |
| 151 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore |
| 152 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore 15mm nominal bore |
| 153 | Providing and fixing PTMT grating of approved quality and colour. 100 mm nominal dia |
| 154 | Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m, including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth, including consolidating each deposited layers by ramming, watering etc., stacking serviceable material rmeasurements and disposal of nserviceable material as directed, within a lead of 50 m :Ordinary rock : Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia |
| 155 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete |
| 156 | 150 mm dia. R.C.C. pipe |
| 157 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design : |
| 158 | 150 mm dia. R.C.C. pipe |
| 159 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame o f 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 100x100 mm size P type With Sewer bricks conforming to IS : 4885 |
| 160 | Constructing brick masonry M.H. in C.M. 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with C.M. 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in C.C. 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : |
| 161 | Inside size 90X80X45 cm i/c C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With Sewer bricks conforming to IS : 4885 |
| 162 | Extra for depth for manholes : |
| 163 | Size 90x80 cm- With Sewer bricks conforming to IS : 4885 |
| 164 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. All types of soil 300 mm dia |
| 165 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineerin- charge. |
| 166 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia having minimum wall thickness 5.00 mm |
| 167 | Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge. 150 mm nominal size dia |
| 168 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. |
| 169 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 150 mm dia. |
| 170 | Providing and fixing M.S. clamp of required dia to the top of casing/housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts f required size complete. 150 mm clamp |
| 171 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I): 150 mm dia. |
| 172 | P/F in position pre cast RCC manhole cover and frame of required shape and of approved quality. Rectangular shape 600x450mm internal dimensions |
| 173 | Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality Circular shape 560 mm internal dia |
| 174 | Providing MS foot rest including fixing in manholes with 20x20x10cm cement concrete blocks 1:3:6 as per standard design. (i) with 20x20mm square bar |
| 175 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. All types of soil 300 mm dia |
| 176 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge |
| 177 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge |
| 178 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. |
| 179 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineerin- charge. |
| 180 | Supplying, assembling, lowering and fixing in vertical position in bore well,unplasticized PVC medium well casing (CM) pipe of required dia,conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 150 mm nominal size dia |
| 181 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia |
| 182 | Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 150 mm dia. |
| 183 | Providing and fixing M.S. clamp of required dia to the top of casing/housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts f required size complete. 150 mm clamp |
| 184 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I): 150 mm dia. |
| 185 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe |
| 186 | Excavation in Soil with Dozer with lead upto 100 metres (Excavation for road way in soil by mechanical means including cutting and pushing the earth to site of embankment upto a distance of 100 metres (average lead50 metres), including trimming bottom and side slopes in accordance with requirements of lines, grades and cross sections.) |
| 187 | (80 % Total Excavation) |
| 188 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. |
| 189 | Excavation in Ordinary Rock with Dozer with lead upto 100 metres (Excavation for roadway in ordinary rock by deploying a dozer, 80 HP including cutting and pushing the cut earth to site of embankment upto a distance of 100 metres ( average lead 50 metres ), trimming bottom and side slopes in accordance with the requirementsof lines, grades and cross sections.) |
| 190 | Ordinary rock (20 % Total Excavation) |
| 191 | Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal within all lifts and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross sections. Mechanised |
| 192 | Hard rock (10 % Total Excavation) |
| 193 | Fillling in foundation trenches as per drawing and technical specification Clause 305.3.9 Earth filling |
| 194 | Disposal of Excavated earth/rock unserviceable, upto dumping zone near national highway distance upto 10km from site |
| 195 | Concrete with cement, coarse sand and 40 mm gauge stone ballast in proportion 1:4:8 in foundations and floors including supply of all material, labour and T&P etc. required for proper completion of the work. as per drawings and technical specifications Clause 802, 803, 1202 & 1203 |
| 196 | Stone masonry work in cement mortar in foundation complete as per drawing and technical specifications Clauses 702, 704, 1202 & 1203, Random rubble masonry In cement mortar (1:4) |
| 197 | Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7 |
| 198 | Hand Packed stone filling in back of wallls including cost of all materials, royality, T&P etc. complete as per direction of Engineer-in- charge. (As per PWD Uttarakhand specifications) |
| 199 | Granular Sub-base with Well Graded Material By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. |
| 200 | For Grading I Material |
| 201 | For Grading II Material |
| 202 | Cement Concrete (PCC M-30) Pavement:-Construction of Un-reinforced, Cement concrete pavement, thickness as per design, over a prepeared sub base with 43 grade cement or any other type PCC Grade M-30, coarse and fine aggregates conforming to IS: 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less then 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (Steel channel, laying and fixing of wedges, steel plates including levelling the formwork and laying and fixing of 125 micron thick polythene film, as per drawing), spreading the concrete with shovels, rakes, compacted using needle, and plate vibrators, finished in continuous operation and curing of concrete slabs for 14 days, using curing compound where specified and water finishing to lines and grade as per drawings and technical specifications. |
| 203 | Supplying, fitting and placing TMT bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202 |
| 204 | Providing and filling in position, blown bitumen in expansion joints. |
| 205 | Laying Cement Concrete Pipe NP3 (burried conduits) on first class bedding of granular material including fixing collar with cement sand mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonary work in head wall and parapets. |
| 206 | 300 mm dia. |
| 207 | Providing and Laying of Interlocking Concrete Block Pavements of M-40 Grade having thickness 80 mm as per drawings and Technical Specification Clause 1504. |
| 208 | Cast in Situ Cement Concrete M 20 Kerb with Channel(Construction of cement concrete kerb with channel with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M10 grade foundation 150 mm thick, kerb channel 300 mm wide, 50 mm thick in PCC M20 grade, sloped towards the kerb, kerb stone with channel laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408) Using Concrete Mixer |
| 209 | Painting Two Coats on New Concrete Surfaces Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701 |
| 210 | Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizescomplete as required. |
| 211 | 150mm dia |
| 212 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including,Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on thewall/ceiling with suitable clamp/support frame and painting with two or more coats of synthatic enamel paint of required shade complete as required : |
| 213 | 25 mm dia |
| 214 | 32 mm dia |
| 215 | 40 mm dia |
| 216 | 50 mm dia |
| 217 | 65 mm dia |
| 218 | 80 mm dia |
| 219 | 100 mm dia |
| 220 | 150mm dai |
| 221 | 200mm dai |
| 222 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : |
| 223 | Single headed Stainless steel |
| 224 | Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blankGunmetal/Stainless Steel cap and chain as required : |
| 225 | Single headed Stainless steel |
| 226 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gasketsconforming to IS 13095 of following sizes as required : |
| 227 | 100mm |
| 228 | Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required |
| 229 | 100mm |
| 230 | 150mm dai |
| 231 | 200mm dia |
| 232 | Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. |
| 233 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required |
| 234 | 200 mm |
| 235 | 100mm |
| 236 | 150mm dai |
| 237 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.80mm |
| 238 | 100 mm |
| 239 | 200mm |
| 240 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required |
| 241 | Stainless Steel (Grade 304) |
| 242 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. |
| 243 | 30 mtrs |
| 244 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required |
| 245 | Stainless Steel (Grade 304) |
| 246 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required |
| 247 | 4 way-150 mm dia M.S. Pipe |
| 248 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. |
| 249 | Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : |
| 250 | Pendent Sprinkler |
| 251 | Upright Sprinkler |
| 252 | Horizontal Side wall |
| 253 | Concealed sprinkler |
| 254 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. |
| 255 | Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. |
| 256 | 100mm |
| 257 | Providing, fixing, testing & commissioning ofinstallation control valve of cast iron body,brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/ sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasketetc of follwing sizes as required : |
| 258 | 100 mm |
| 259 | Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. |
| 260 | 700mm |
| 261 | 1000mm |
| 262 | 1200mm |
| 263 | 1500mm |
| 264 | Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required |
| 265 | Providing and fixing of Stainless Steel Fire brigade Suction Hose Coupling (draw out connection) with nut for female coupling as per IS 902-1974 complete. |
| 266 | Design and construction of 200 KL (2 Part) capacity, RCC Under Ground Tank, Pump Room with suitable foundation Considering Seismic forces, including supply of all materials, labour, T&P etc. as required for proper completion of work. The earthquake resistant design must be in conformity with IS:456, IS:1893, IS:13932 & IS:13920 (latest versions). RCC work for water retaining portion should be not less than M-25 (design mix). The work will include submission of detailed design & drawings and Vetting before starting of the work, as per direction of client /employer. |
| 267 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 268 | FIRE EXTINGUISHERS |
| 269 | Providing and fixing carbon-di-oxide fire extinguishers trolley mounted with all accessories internal discharge tube,high pressure discharge hose, discharge nozzle, suspension bracket, ISI marked as per IS:2878 Finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. |
| 270 | Capacity 22.5 Kg. |
| 271 | Providing and fixing Carbon-di-oxide Fire Extinguishers consisting of welded M.S cylindrical body, squeeze lever discharge valve fitted with internal discharge tube. 30cms long high pressure discharge hose. Discharge nozzle,suspension bracket, confirming to IS:934 finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete with internal charge. (CCOE Nagpur Approved clynders) |
| 272 | Capacity 4.5 Kg. |
| 273 | Providing and fixing of ABC type (Stored Pressure) Fire Extinguisher I.S.I marked & T.A.C.approved complete in all respect. |
| 274 | 4 kg. capacity |
| 275 | Providing & fixing carbon steel Fire man axe with rubber insulated handle tested to 20000 volts. |
| 276 | Providing and fixing Mechanical foam ( AFFF) Fire Extinguisher I.S.I marked & T.A.C.approved complete in all respect. |
| 277 | Capacity 9 Ltr. |
| 278 | Providing and Fixing of self illuminated /auto glow Exit signs printed on photoluminescent sheet containing self illuminated base chemical,of appropriate size not less than 400x150mm,suspended from ceilling or fixed to the walls with accessories as riquired and as directed at site. |
| 279 | Supplying, installation, testing & commissioning of main control and indicating panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm and public address system, monitoring system including connections, interconnections etc complete as required. 10 Zone panel for fire alarm system 250 Watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all accessories as required - 2 Nos.(one to act as standby) Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communicationsuitable for 20 Nos.talk back unit -1 set. |
| 280 | Talk back master station with LED PTT (press to talk) push button for operation on 230V AC/24 V DC supply conforming to IEC-268 for simplex mode of operation/communication suitable for 20 Nos.talk back unit -1 set. Annoucement control desk suitable for selection of different zones selectively and ON ALL CALL switch with visual indication etc., complete as required- 1 set. Amplifier change over switch for inter changing amplifier- 1 No. Monitor panel for loudspeaker complete output selector ON/OFF switch, fuse visual indications etc. complete as required- 1 No. Gooseneck microphone with stand and ON/OFF switch -1 No. Mains ON/OFF switch, fuse indication lamps, DC and AC voltmeters & ammeters terminal blocks etc. complete as required -1 set. Battery charger trickle cum boost to take complete load of fire alarm & PA system complete with all accessories including providing & fixing of 2 nos. 12 volt,30 AH each sealed maintenance free batteries -1 set. |
| 281 | Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required 4 zone |
| 282 | Supplying, installation, testing & commissioning of addressable manual call point complete as required. |
| 283 | Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required. |
| 284 | Supplying, installation, testing & commissioning talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. knob & speaker/microphone enclosed in a M.S.(16 SWG)/ ABS box with break glass in front etc. complete as required |
| 285 | Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required. |
| 286 | Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required |
| 287 | Supplying, installation, testing & commissioning ofceiling/wall mounted loud speaker, 3/1.5 Watt in ABSenclosure complete as required |
| 288 | Supplying, installation, testing & commissioning of digitalaudio amplifier 75 Watt, 25V rms operating at 240 Volt AC Supply complete as required. |
| 289 | Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required |
| 290 | Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. |
| 291 | Supplying and drawing of cable Fire Retardant PVC insulatedcopper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required |
| 292 | speaker cable Two pair, 2-core, 1.5 sqmm |
| 293 | speaker cable Four pair, 2-core, 1.5 sqmm |
| 294 | Brick work with common burnt clay machine moulded perforated modular bricks of class designation 12.5 conforming to IS : 2222 in exposed brick work including making horizontal and vertical grooves 10 mm wide 12mm deep complete in cement mortar 1:6 (1 cement : 6 coarse sand). |
| 295 | From ground level upto plinth level |
| 296 | Above plinth level upto floor V level |
| 297 | Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. |
| 298 | The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works. |
| 299 | Applying breathable, non-reactive, antifungal, and water repellant Silane/Siloxane chemical as approved by Archaeological Survey of India/ Engineer-in-charge, of approved brand and manufacture, diluted with solvent mineral Turpentine oil in the ratio of 1:12 (One part of approved chemical :12 Part of Turpentine oil), on the existing sand stone masonry surface with two or more coats to give uniform application of chemical on the surface, all complete as per direction of Engineer-In-charge (The rate is inclusive of all materials & labours involved except scaffolding). |
| 300 | Cleaning of exposed concrete, Brick, Stone surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. |
| 301 | Wiring for light point/ fan ponit/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group-C |
| 302 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed Steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 303 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 304 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. |
| 305 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 306 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 307 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 308 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 309 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 310 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair |
| 311 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 312 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 313 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 314 | 20 mm |
| 315 | 25 mm |
| 316 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 317 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 318 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 319 | Supplying and fixing of following ways surface/ recess mounting, Vartical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. 8Way (4+24), Double door |
| 320 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6way 4+18 Double Door |
| 321 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and neutral |
| 322 | Single pole |
| 323 | Single pole and neutral |
| 324 | Triple pole and neutral |
| 325 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 326 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. |
| 327 | Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 328 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 329 | P/F Hexagonal MS sheet fan box for ceiling fan clamp od internall dia 140mm, 73mm height top lid of 1.5mm thick MS sheet with its top surface hacked, MS clamp shall be made of 12mm dia MS bar bent to shape as per standard design. |
| 330 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 331 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 332 | 5/6 A switch |
| 333 | 3 pin 5/6 A socket outlet |
| 334 | Telephone socket outlet |
| 335 | TV antenna socket outlet |
| 336 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 3 module |
| 337 | Providing and fixing plain 16/0.20mm (0.50sqmm) twin circular flexible FRLS PVC insulated, PVC sheathed copper conductor cable direct on the wall with PVC clips etc. as required. |
| 338 | Supply, Installation, Testing and commissioning of of Ceiling mounted type 100 watt High Bay suspension Type Luminary with matallic adjutable Bracket with Eye Bolt 3500K ,140-300V, 50 Hz, pf >=0.95, Pressure Die Cast Aluminium Alloy Housing, Minimumm lamp Effeciency 120 lm/W, polycarbonate UV Stablised Optical Type diffuser,in built control gear having driver efficiency more than equal to 85%, minimum CRI-70, Ingress Protection IP67, Total Harmonics less than 10%,Beam Angle >=120,Lumen Maintenance >=80% after 6000 burning Hours, capable to with stand 1.5 Kv Surge voltage for one minite ,5 KV Transient Surge,,minimum 50000hours LED Life,as per IS 15802Part.XV Section-2 & 16105 Part-2 sec.1, 2012 latest along with Photobioloical safety LED as per IS:16108/2012 /IEC:62471;2006. completewith all accesories including Installation at hight upto 10 meters connections, Testing etc as required. |
| 339 | Supply, of of Surface mounted type 36 watt LED Batten 6500K cool white SMD LED light source,1150mm ,140-270V, 50 Hz, pf >=0.9, Aluminium Housing, Minimumm lamp Effeciency 100lm/W,Chip Efficency 130lm/W, polycarbonate diffuser,in built control gear havi |
| 340 | Supply of 300 swwep ISI Marked 4 pole ,3 blades,capacitor Type E Class Insulation , Propeller Type totally enclosed Motor Exhaust fan as per IS 2312/1967 Latest compleate with all accessories with Bird Screen suitable to operate on 240V single phase 50 Hz AC supply with o.0 9Pf and minimum Air Delevary as per table-2 of IS2312 :1967 and maximum Wattage Input as per table 2 of IS 2312:1968 including Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. as reqd. |
| 341 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 3742019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 342 | Supply of recessed mounted type 12 watt LED RoundDownlighter Luminary 6000K cool white ,140-280V, 50 Hz, pf >=0.9, Die Cast Aluminium Housing, Minimumm lamp Effeciency 100 lm/W,Chip Efficency 130lm/W, polycarbonate diffuser,in built control gear having driver efficiency more than equal to 85%, minimum CRI-80, Ingress Protection IP20, Total Harmonics less than 20%,Beam Angle >=120,Lumen Maintenance >=80% after 6000 burning Hours, capable to with stand 1.5 Kv Surge voltage for one minite 2.5 KV Transient Surge,,minimum 50000hours LED Life,as per IS 10322Part.V & 10107 Part-2 sec.1, 2012 along with Photobioloical safety LED as per IS:16108/2012 /IEC:62471;2006. completewith all accesories etc as required. |
| 343 | 20 W HE Polycab LDO0103076 20WLED6500K Batten Tube |
| 344 | Supply, of recessed/Surface mounted type 36 watt 2x2 LED PanelLuminary 6000K cool white ,140-280V, 50 Hz, pf >=0.9, Extruded Aluminium Housing, Minimumm lamp Effeciency 100 lm/W,Chip Efficency 130lm/W, polycarbonate Reflector Type diffuser,in built control gear having driver efficiency more than equal to 85%, minimum CRI-80, Ingress Protection IP20, Total Harmonics less than 20%,Beam Angle >=120,Lumen Maintenance >=80% after 6000 burning Hours, capable to with stand 1.5 Kv Surge voltage for one minite 2.5 KV Transient Surge,,minimum 50000hours LED Life,as per IS 10322Part.V Section-2 & 10107 Part-2 sec.1, 2012 along with Photobioloical safety LED as per IS:16108/2012 /IEC:62471;2006. completewith all accesories etc as required. |
| 345 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 346 | Supply,Installation, testing and commissioning of Wall fan 3 Aluminium baldes 400mm sweep,1000-1500RPM,air Delevary 40-350 cubic meter/min,with pull chord Regulator control, 65 W Power consumption with Vartical Adjutable Tilt Mehanisum including fixing , connections etc. as required. |
| 347 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 348 | Design, Fabrication, Supply, Erection,Testing and commisioning of Powder coated Main Distribution Panel fabricated out of 14 guage CRCA sheet steel in cubical, compartmentallised, FRLSee standing floor /wall mounted, dust and vermin proof, with reinforcement of suitable size angle iron, channel, T -iron or flats as required. Cable gland plates shall be provided on top as well as bottom of the panels. Panels shall be treated with all anti-corrosive process before painting as per specification. Panels shall be suitable for 415V, 3-Phase, Four wire, 50 Hz supply complete with earth bus and lifting hooks as required in case of large panels.Approval shall be taken for each panel before fabrication. (All hardwares like nuts and bolts used shall be Galvanized and Zinc passivated |
| 349 | Building LT Panel as per specification mentioned below |
| 350 | INCOMER |
| 351 | 400 A, FP, MCCB ,50 KA - 1 No... |
| 352 | OUTGOINGS |
| 353 | Outgoing - 200 amp 36 KA FP MCCB -2no.,Outgoing - 100 amp 36KA FP MCCB-4nos |
| 354 | Providing & Fixing of vartical ISI Marked ABS Engineering Plastic Gyser (water Heater) 25 Liter Capacity. BEE 5 Star Rating with Vitrious Enamel vented type inner Container as per ISIS 2082:2018 latest 60N/Sq.cms. Pressure Rating with pressure safety Release and 2 meters Extension Chord and all standatd mountings and accessories , making water connection etc as reqd. |
| 355 | S/F single pole blanking plate in the existing MCB DB complete etc. as required. (4 no. /MCBDB) |
| 356 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. asrequired. |
| 357 | Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 358 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. For AC |
| 359 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate One Module for modular switches in recessincluding supplying and fixing Anchor Cat-6 Data Information Outlet, crimpling, connection, testing etc. as required. |
| 360 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 2 cable run |
| 361 | Supplying installation testing commissioning of 24 Port, 2 layer,Web Managed, 4 SFP Port, 56 Gbps switching capacity,41.7MPPS Thoughtput,Data switch Dlink with 2 U rack , cable maneger etc as reqd. |
| 362 | Supply, of Surface mounted type 10 watt LED Batten 6500K cool white SMD LED light source,552mm ,100-300V, 50 Hz, pf >=0.9, Aluminium Housing, Minimumm lamp Effeciency 100lm/W, polycarbonate diffuser, in built control gear having driver efficiency more than85%, minimum CRI-80, Ingress Protection IP20, Total Harmonics less than 20%,Beam Angle >=120,Lumen Maintenance >=80% after 6000 burning Hours, capable to with stand 2.5 Kv Surge voltage,minimum 50000hours LED Life,as per IS 103229Part.V sec.1, 2012 along with Photobioloical safety LED as per IS:16108/2012 /IEC:62471;2006. completewith all accesories etc as required. |
| 363 | Supplying and fixing 8 way, Double Door single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 364 | Supply of 18W Inverter LED batten with backup 4 hrs , Charging Time 8 hours, 6300K,85% Driver Efficeincy,,system Efficiency 100lm/W,system current less than 106mA,builtin Electronic Control Gear ino. Li-Ion Batteru having Backup of 6 hours,with Extruded Aluminium Housing, Polycarbonate Diffuser, minimum CRI-80, Ingress Protection IP20, Total Harmonics less than 20%,Beam Angle >=120,Lumen Maintenance >=80% after 6000 burning Hours, capable to with stand 1.5 Kv Surge voltage for one minite 2.5 KV Transient Surge,,minimum 50000hours LED Life,as per IS 10322Part.V & 10107 Part-2 sec.1, 2012 along with Photobioloical safety LED as per IS:16108/2012 /IEC:62471;2006. completewith all accesories etc as required |
| 365 | Supply, of surface Mounted 9-10 watt LED bulk Head Plastic Luminary 6500K cool white ,240 v, 50 Hz, pf >=0.95, Die Cast Aluminium Housing, Minimumm lamp Effeciency 100 lm/W,Chip Efficency 130lm/W, polycarbonate diffuser,in built control gear having driver efficiency more than equal to 85%, minimum CRI-80, Ingress Protection IP55, Total Harmonics less than 20%,Beam Angle >=120,Lumen Maintenance >=80% after 5000 burning Hours, capable to with stand 2.5 KV Transient Surge,,minimum 50000hours LED Life,as per IEC safety Class (1)i completewith all accesories etc as required. |
| 366 | Providing and fixing 100 amps 36 KA breaking capacity Four pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required |
| 367 | Providing and fixing 200 amps 36 KA breaking capacity Four pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required |
| 368 | Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 369 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) |
| 370 | Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run |
| 371 | Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I.bolts, nuts, chuck nuts and spring washers etc. complete as required. |
| 372 | Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. |
| 373 | For independent feeder terminal equipment at sending end including swithch gear, ht cables, ct pt, meter cubicle etc 1 sets. |
| 374 | Over Head 11 KV Line Cost |
| 375 | Security Deposit for Rs. 1500/KW for 250KW |
| 376 | Supplying,installation,testing and commisioning of 400Kva 11kV/0.433 kV outdoor Package type compact substation equipments comprising HT Panel, Transformers, HT cable, Bus trunking from Transformer to LT Panel, LT Panel, Automatic Power factor correction panel, Active Harmonic Filters,TVSS (Transient Voltage suppression system), SPD (Surge protection system), Essential panel,Earthing,required inter-connections, substation safety euipments including LT cabling from sub station to the buildings fed by the sub station. ( LT Panell having 800 amps 50 KA FPMCCB incomer with 1 nos 650 amps 50KA MCCB 1no and 400 amps 50 KA MCCB 2 nos as Outgoings0 |
| 377 | S/F XLPE insulated screened PVC beded galvanized steel strip of wire armoured electric power cable (heavy duty) with aluminium conductor 11KV greds cross sectional area 120 sqmm as per diected by engineer-in-charge. For metering eqpt. |
| 378 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 379 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe FRLSom earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 380 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. |
| 381 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 382 | Supplying and making end temination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium couductor cable of 1.1 KV grade as required. |
| 383 | 3.5x35 |
| 384 | 3.5x70 |
| 385 | 3.5x95 |
| 386 | 3.5x120 |
| 387 | 3.5x185 |
| 388 | 3.5 x 240 sq. mm |
| 389 | S/M OUTDOOR cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required: upto 120 sq. mm |
| 390 | supplying and making indoor cable end termination with heatshrinkable jointing kit complete with all accessories includinglugs suitable for following size of 3 core,120 sq.mm, XLPE aluminiumconductor cable of 11 KV grade as required : |
| 391 | S/E of three piece nonlinear resistor type lighting arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharege current rating of 5 KV and complete with galvanised clamping arrangenment, G.I. bolts, nuts, washers etc. as required. |
| 392 | 6 meter GI octegonal pole single arm with loop in box Bajaj |
| 393 | Erection of Octagonal street light pole of 6 to 8 meter length in RCC 1:2:4 foundation including excavation, refilling, Reinforcement etc. as per Pole Manufacture design. |
| 394 | Supplying and fixing 60W LED streetlight made up of pressure die cast housing with toughned glass and individual LEDs with secondary optics and IP66 protection complete with all accessaries. |
| 395 | Supply, installtion Testing and commissioning of 150 W LED Smart Flood Light Sakti Led-150W-FL |
| 396 | Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade aluminium conductor armored of following size in the existingRCC/ HUME/ METAL pipe as required. |
| 397 | 2x6 sq.mm |
| 398 | 3.5x35 Sqmm |
| 399 | 3.5x70 Sqmm |
| 400 | 3.5x95 Sq.mm |
| 401 | 3.5x 185 Sq.mm |
| 402 | 3.5x240 Sqmm |
| 403 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required |
| 404 | 110mm |
| 405 | 150mm |
| 406 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required |
| 407 | 300mm |
| 408 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 409 | 160mm |
| 410 | Supply, Installation, testing and commissioning of 62.5KVA Salient Type DG set, AMF Panel, bus ducting/ cables from DG set to Essential Panel, Synchronising Panel if reqd., DG set Enclosure room sound insulation, ventilation, smoke exhaust, Earthing of DG set System, control cabling, fuel Tank piping,exhaust chimney and piping,as per CPCB norms, civil works connected with DG sets, including foundation etc. as reqd. 2Sets DG SETS Power Generator- DG set of 500 AMF Control Panel |
| 411 | Supply ,installation testing and commissioning of MiniSpace 13 Pessenger (884Kg) lift having contract speed of 1.0 m/s serving for different floors (G+4) 5 floors, Type(MRL) Machine room less with gearless traction having + /- 5% landing accuracy, speed 1.0 mps, 5levels with a total travell of 13 mtrs,(approx.) with 4 stops and all opening all on one side, with VAVF cotroller,having ARD with Dry MF batterirs, Microprocessor based simples slective collective with attendent operations,415 V 50 Hz 3 phase 4 wire power, with power operated centre opening horizontal sliding stainless steel scrach free car and landing doors, infra red curtain and one hour fire rating, with overload waring indiactor, concealed luminary with LED light, axial pressure ceiling fan, . with voice annoucement system. etc as required. |
| 412 | Supply ,installation testing and commissioning of U MiniSpace 20 Pessenger or BED (1360Kg) lift having contract speed of 0.75 m/s serving for different floors (G+5) 6 floors , Type(MRL) Machine room less with gearless traction having + /- 5% landing accuracy, speed 0.75mps, 6 levels with a total travell of 22.5 mtrs, (approx.) with 6 stops and all opening all on one side,with VAVF cotroller,having ARD with Dry MF batterirs, Microprocessor based simples slective collective with attendent operations, 415 V 50 Hz 3 phase 4 wire power,with power operated centre opening horizontal sliding stainless steel scrach free car and landing doors, Car size and dimenssions suitable for hospital strchers, infra red curtain and one hour fire rating, with overload waring indiactor, concealed luminary with LED light, axial pressure ceiling fan, with voice annoucement system. etc as required. |
| 413 | Supplying, installation, testing and commissioning of online 3 phase UPS Systemwith 30 minutes back up including batteries, interconnecting cables, battery racksetc |
| 414 | Supplying, installation, testing and commissioning of IP based EPABX System comprising of Core switches & L2 switches with 10 G, 10 Giga SFP modules, Industry Standard Appliance Server, Cloudbased, enterprise-grade UC Solution, MID/ENTRY Level IP/SIP Phone with, Dual 1 Gig Ports, Racks, CAT 6A cable, Patch Panels, OFC etc. |
| 415 | Supply,Installation,Testing&Commissioning of modular type VariableRefrigerantFlow/ Variable Refrigerant Volume aircooled Outdoor units suitableforcooling andheating,having all hermetically sealed invertertype Scroll Compressor(s), minimum two compressors for above14HPmodules, microprocessor based Controller, top discharge type condensing unit(s) ,withR410A Refrigerant, vibration isolators, withsuitable foundationetc. complete asrequired. Theunitshalldeliver the rated capacity at AHR IConditionsandworkevenat 50°C ambienttemperature without tripping. The unit shall be suitable to workon 400V+/-10%, 3Phase, 50Hz AC powersupply.Theunit shall be filled with first charge of the refrigerant and ready for use as required.The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 . 2x20 HP |
| 416 | Supply,installation,testingandcommissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/ dynamicallybalancedblower, multispeedmotor, coilsection with DX Coppercoil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports,vibrationisolation, cordless remote control etc., suitable for operation on singlephase230V±10%,50Hz AC supply, complete,asrequired. The unit shall have automatic force shutdown provision in caseof fire on receiving signal fromBMSSystem. The cooling capacity of indoorunit will be at air inlet conditionsof27DegreeCDBand19Degree CWB temperature. |
| 417 | 1.6 TR |
| 418 | Supply,installation,testingandcommissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor wall mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/ dynamicallybalancedblower, multispeedmotor, coilsection with DX Coppercoil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports,vibrationisolation, cordless remote control etc., suitable for operation on singlephase230V±10%,50Hz AC supply, complete,asrequired. The unit shall have automatic force shutdown provision in caseof fire on receiving signal fromBMSSystem. The cooling capacity of indoorunit will be at air inlet conditionsof27DegreeCDBand19Degree CWB temperature. |
| 419 | 1.4 TR |
| 420 | Supply,Installation,testing and commissioning including vaccumiazationandNitrogentesting of following nominalsizes of soft/hard drawn copper refrigerant piping for VRV/VRFsystem, complete with fittings, with suitablea djustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/withClass-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquidlines,allaccessories as per specifications etc. as required : |
| 421 | 6.4mmdia(OD)(Softdrawn)with tube thickness 1.2mm with19mmthick insulation |
| 422 | 9.5mmdia(OD)(Softdrawn)with tube thickness 1.2mm with19mmthick insulation |
| 423 | 12.7mmdia(OD)(Softdrawn)with tube thickness 1.2mm with19mmthick insulation |
| 424 | 15.86 mmdia(OD)(Softdrawn)with tube thickness 1.2mm with19mmthick insulation |
| 425 | 19mmdia(OD)(Hard drawn)with tube thickness 1.2mm with19mmthick insulation |
| 426 | Supply installation testing and commissioning of Carrier 1.5 Ton 3 Star High wall Split AC (Hot and Cold) CarrierR (Carrier & Superia 365) including initial charging etc. as reqqd. |
| 427 | Supply installation testing and commissioning ofHitachi 2 Ton 3 Star High wall Split AC (Hot and Cold)HitachiR (MODEL NO- RMOG324HDXA) Carrier including initial charging etc. as reqqd. |
| 428 | Supply installation testing and commissioning of Voltas 3 Ton 5 Star Ceiling Mounted Split AC (Cassette AC - Hot and Cold)VoltasR (VOLTAS ICAS 36VH)including initial charging etc. as reqqd. |
| 429 | Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automaticoperation and consisting of following, complete in allrespects, as required (a) Horizontal type, multistage, centrifugal, split casingpump of cast iron body & bronze impeller with stainlesssteel shaft, mechanical seal conforming to IS 1520. |
| 430 | (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operationon 415 volts, 3 phase 50 Hz, AC supply with IP 55protection for enclosure, horizontal foot mounted typewith Class-'F' insulation, conforming to IS-325.(c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered |
| 431 | 2280 LPM at 70 mtrs Head |
| 432 | Supplying, installation, testing and commissioning ofdiesel engine driven main fire pump suitable forautomatic operation and consisting of following,complete in all respects, as required : (Diesel Driven Pump) |
| 433 | Horizontal type, multistage, centrifugal pump of cast ofiron body and bronze impeller with stainless steel shaft,mechanical seal conforming to IS 1520. |
| 434 | Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thickaluminium sheet cladding, residential silencer,instruments and protection as per standard specification, stop solenoid for auto stop in the event offault with audio indications, painted with post office redcolour etc. as required. |
| 435 | M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. suitable cement concrete foundation duly plasteredand with anti vibration pads. |
| 436 | 2280 LPM at 70mtrs Head |
| 437 | Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable forautomatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. |
| 438 | suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads. |
| 439 | 180 LPM at 70 mts head |
| 440 | Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainlesssteel shaft, mechanical confirming to IS : 1520Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation,conforming to IS-325 .M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as requiredSuitable cement concrete foundation duly plastered and with anti vibration pads. |
| 441 | 900 lpm at 35 m Head |
| 442 | Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCAsheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, |
| 443 | suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required : |
| 444 | INCOMING 400A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector swtich & CTs etc. |
| 445 | LED type RYB phase indicating lamps, ON, OFF, trip ndicating lamps Set of Copper Bus Bar 300A OUTGOING ( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) |
| 446 | Main Fire Pump200 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. |
| 447 | Jockey Pump100 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiringrequired for automatic operation, selector switch for local/remote, auto/manual/OFF operation. |
| 448 | DIESEL ENGINE CONTROLControl for diesel engine comprising -Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter |
| 449 | All standard relays and accessories for automatic operation of diesel engineSystem Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operationof main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciationwindow for fault indication, complete as perspecification |
| 450 | Supplying and installing 4 MP IP CCTV Bullet camera,CP Plus. |
| 451 | Supplying and installing 4 MP IP CCTV Dome camera,CP Plus. |
| 452 | POE Acess Switch 24 Port |
| 453 | D-Link 6U Rack Enclosures Networking/Server Rack with cable management and Connectors etc. as reqd. D-LinkR(NWR-6U-5045-GR) |
| 454 | 64 Input and 4 Output Channel Video Recorder For Cctv SystemSparshR(SR-NP3232F5H-H(E)(D)(P)) |
| 455 | Sony 82 cms LCD Panel monitor. |
| 456 | FES 8 Ports Managed PoE+ Layer 2 Access Switch FESR (FES-GS-1010P) |
| 457 | HT HDMI1.4 Cat.6 10.2 Hdmi ExtenderIHTR (IHT-HDMI-E60NTS (60Mtrs)) |
| 458 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 459 | 20 mm |
| 460 | 25 mm |
| 461 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 2 cable run Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail