| 1 | Running, opreation & maiteneance of DG set, PA system, re-wiring of speakers as per inventory, BOQ, terms and conditions attached. Deploying following staff etc. complete as reqd. Opretor Gr-II - 1 No. daily Wireman Gr-II -1 No. - 4 days a month Khallasi-1 No daily |
| 2 | LED Batten light (System lumen efficacy ≥105 85%, Operating voltage AC 140 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 3 | Servicing of existing installed DG set of 110 KVA from OEM ( Kirloskar Make) along with supply and replacement of worn out parts such as fuel filter kit, Airfilter, oilfilter, engine oil/Mobil oil, coolent , i/c testing, commissioning and cartage etc complete as required. |
| 4 | Brush Less Direct Current (BLDC) Fan with Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.(1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) ) |
| 5 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 KA , \\"C\\" curve miniature circuit breaker suitable for inductive load of the following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 6 | Single Pole |
| 7 | Double Pole |
| 8 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. |
| 9 | 32 A TP&N |
| 10 | 63 A TP&N |
| 11 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic rele ase and terminal spreaders in existing cubicle panel b oard including drilling hol es in cubicle panel, making connections, etc. as required. |
| 12 | 125 A, 36 KA, FPMCCB |
| 13 | 200 A, 36 KA, FPMCCB |
| 14 | Supplying and drawing and following sizes of FRLS/HFFR PVC insulated copper conductor single core cable in recessed the existing surface.steel/PVC conduit as required |
| 15 | 1x1.5 sq mm |
| 16 | 3x4 sq mm |
| 17 | Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. |
| 18 | 5/6 A swtich |
| 19 | 15/16 A switch |
| 20 | 3 pin 5-6 A socket outlet |
| 21 | 6 pin 15-16 A socket outlet |
| 22 | Supplying and making of straight through joint with heat shrinkable kit i/c ferrules and other jointing material for following size of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as reqd. |
| 23 | 2x16 sq.mm |
| 24 | 4x25 sq.mm |
| 25 | Supply of the following size XLPE AI. Conductor armoured cable of size 1.1 KV grade i/c connection, testing etc. as required. |
| 26 | 2x16 sq.mm |
| 27 | 4x25 sq.mm |
| 28 | Laying of one number PVC insulated and PVC sheathed /XLPE power cable of 1.1 KV grade of following sizes in the existing RCC/HUME/Metal Pipe as required. |
| 29 | Upto 35 sq. mm Please Enable Macros to View BoQ information |