| 1 | BOQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: CHIEF ENGINEER(AF) BANGALORE Name of Work: COMPLETION OF INCOMPLETE WORK OF IMPROVEMENT TOT CERTAIN MARRIED QUARTERS AT VSV AREA AT AFS BIDAR Contract No: CE AF/BAN/ OF 2025-26 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of work Item Code / Make No or Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES |
| 2 | SCHEDULE A PART I (B/R Works)Demolition of cement concrete of any description and in any position not otherwise specifically provided for, including removing the rubbish debris to low laying area all as specified and directed. |
| 3 | Demolition of cement concrete in ground floors and pavings not exceeding 15cm thickness (below ground level) including removing the rubbish debris to low laying area complete all as specified and as directed. |
| 4 | Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing and rubbish off the premises to low laying area, as specified and as directed. |
| 5 | Taking up or down 15 mm bore steel tubing and connections etc complete all as specified and as directed. |
| 6 | Taking up or down 20 mm bore steel tubing and connections etc complete all as specified and as directed. |
| 7 | Taking up or down 25 mm bore steel tubing and connections etc complete all as specified and as directed. |
| 8 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided complete including removing the rubbish debris to low laying area all as specified and as directed. |
| 9 | Dismantling water tanks of capacity exceeding 250 Ltrs capacity & not exceeding 500 Ltrs capacity etc complete all as specified and as directed. |
| 10 | Taking down wooden chowkats or frames with shutters (without taking off shutters from the frame) not exceeding 1.5 sqm each complete all as specified and as directed. |
| 11 | Taking down wooden chowkats or frames with shutters (without taking off shutters from the frame) exceeding 1.5 sqm but not exceeding 4.0 Sqm each complete all as specified and as directed. |
| 12 | Taking down Shutters of any description exceeding 1 sqm but not exceeding 2 sqm each complete all as specified and as directed. |
| 13 | Dismantling boarding of any description, fixed in any position with nails, as in shelves complete all as specified and as directed. |
| 14 | Taking down cement plaster on bricks or stone walls etc, including raking out joints, hacking for key scrubing down with water etc.to receive plaster etc, complete all as specified and as directed. |
| 15 | Demolition of brick work or stone/Boulder masonry built in cement mortor incl all quoins, arches, pillars etc. but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and as directed. |
| 16 | 25mm thick cement concrete type B0, 1:2:4, (using 12.5 mm graded aggregate) as in floor finishes for floor complete all as specified and as directed. |
| 17 | 15mm thick screed bed or bedding layer of mortar in CM 1:6 for laying floor finishes complete all as specified and as directed. |
| 18 | Non-skid Ceramic coloured tiles 7-8 mm thick (square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm in floors of rooms etc. set and jointed in neat cement slurry (grey cement) and pointed in white or coloured cement to match complete all as specified and as directed. |
| 19 | Non-skid Ceramic coloured tiles 7-8 mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in toilet floors etc., set and jointed in neat cement slurry (grey cement) and pointed in white or coloured cement to match, all as specified and as directed. |
| 20 | Rendering 10mm thick in CM 1:3 on fair faces of brick work/concrete surfaces, using as backing coat, skirting/dado, all as specified and as directed. |
| 21 | Glazed ceramic coloured tiles(300x200)x7 mm thick vertical surface as in dado/skirting, set and jointed in neat cement slurry, (grey colour) and pointed in white or coloured cement to match with the colour of the tiles, complete all as specified and as directed. |
| 22 | Pre-polished kota stone slab 20-25 mm thick in single piece as in treads and risers of staircase etc laid over and including cement screed bed of thickness 20mm in CM 1:6 and jointed with grey cement pigment, including rubbung and polishing complete all as specified and as directed. |
| 23 | Plain cement concrete Type E2 , 1:5:10 , using 40mm graded stone aggregate as in filling and mass concrete complete all as specified and as directed.. |
| 24 | 20mm outer dia water tubing with 3 layered PP-R (Polypropylene random copolymer) concealed pipes SDR 7.4 (PN-16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass thread polypropylene random fittings fixed complete to walls, ceiling or in floors etc, complete all as specified and as directed. |
| 25 | 25mm outer dia water tubing with 3 layered PP-R (Polypropylene random copolymer) concealed pipes SDR 7.4 (PN-16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass thread polypropylene random fittings fixed complete to walls, ceiling or in floors etc, complete all as specified and as directed. |
| 26 | Stainless steel sinks kitchen with draining board made out of 1 mm thick overall size 915 x 460 mm with bowl size 410 x 330 x 160 mm with plugs, washers, and wastes; including bedding in cement mortar on to dwarf walls, or including fixing cantilever brackets and connecting union to waste pipe upto 0.5 Sqm each including removing old sink, as specified and directed. |
| 27 | Blank |
| 28 | 15mm bore chromium plated cast copper alloy bib taps fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed in repairs all as specified and as directed. |
| 29 | 15mm bore stop valves, cast copper alloy fancy type chromium plated with long shank and cup (concealed type), screw down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, fixed in repairs complete all as specified and as directed. |
| 30 | 125mm size brass chromium plated shower roses with or without swivel joints, including fixing to steel pipe or union Fixed in repairs complete all as specified and as directed. |
| 31 | Vitreous china , semi pedestal pattern (Anglo Indian type) water closet with 'S' trap, white (excluding fixing bolts, flushing cistern and flush pipe), fixed in repairs, complete all as specified and as directed. |
| 32 | PVC valveless, sypohonic action type low level flushing cistern 10 litres capacity, white, with inlet, ball valve, float and handle including brackets, all as specified and as directed. |
| 33 | S&F 600mm x 450mmx5mm thick mirror of selected quality glass fixed with pivots/screws on wall complete all as specified and as directed. |
| 34 | Blank |
| 35 | PVC connection 450mm long of 15mm bore with pair of brass check nuts, all as specified and as directed. |
| 36 | PVC (SWR) floor trap 75mm of dia with grating including jointing with solvent cement, complete all as specified and as directed. |
| 37 | 20 mm bore gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe, complete all as specified and as directed. |
| 38 | PVC (SWR) gully trap 125mm, seting and jointing with solvent cement, complete all as specified and as directed. |
| 39 | 75 mm bore, PVC (SWR) pipe single socketed in any length with rubber ring joints fixed to wall complete all as specified and as directed. |
| 40 | 110 mm bore, PVC (SWR) pipe single socketed in any length with rubber ring joints fixed to wall complete all as specified and as directed. |
| 41 | 110 mm bore, PVC (SWR) bends any radius, complete all as specified and as directed. |
| 42 | 75 mm bore, PVC (SWR) bends any radius, complete all as specified and as directed. |
| 43 | 110 mm bore, PVC (SWR) junction single (single 'T') equal or unequal, complete all as specified and as directed. |
| 44 | 75 mm bore, PVC (SWR) junction single (single 'T') equal or unequal complete all as specified and as directed. |
| 45 | 110 mm bore, PVC (SWR) vent cowl complete all as specified and as directed. |
| 46 | Rotational moulded polyethylene water storage tanks of capacity 500 litres tripple layered with screwed lid (cylinderical vertical with closed top) hoisted and fixed in position as specified in SSR part I complete all as specified and as directed |
| 47 | Rotational moulded polyethylene water storage tanks of capacity 250 ltrs tripple layered with screwed lid (cylinderical vertical with closed top) hoisted and fixed in position as specified in SSR part I as in for solar water tank complete all as specified and as directed. |
| 48 | 25 mm bore ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed in repairs, completeall as specified and as directed. |
| 49 | Mild Steel Ventilators with centre hung shutter including two pairs of brass cup pivots, catch spring and pully wheel, complete all as specified and as directed. |
| 50 | Mild Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, complete as specified and directed. |
| 51 | Supply and fix solid PVC door frame of size 50mmx47mm, made out of 5 mm single side prelam PVC sheet used instead of plain colour PVC sheet & edges will be painted to match with prelam sheet complete all as specified and as directed. |
| 52 | Factory made solid panel PVC door shutter of thickness 30mm single side prelaminated PVC sheet used instead of plain color PVC sheet and style & rails having one side feathered edge and on other side 10mm 90º, bent edge complete all as specified and as directed. |
| 53 | Pressed steel frames (125 x 60mm) for doors with two rebates thickness of sheet 1.25mm including necessary fixing lugs, hinges, lock strike plate,etc., complete.as specified and directed. |
| 54 | Plain Cement Concrete 1:3:6 type C1 (20 mm graded aggregate) for filling pressed steel door frame complete all as specified and as directed |
| 55 | 35mm thick flush shutters, solid core construction, with particle board core and ply wood face panels, commercial type on both sides and one face is covered with decorative face veneer with lipping / frame to match complete all as specified and as directed. |
| 56 | Second class hardwood glazed and skelton shutters 35mm thick, open rebated and prepared to receive glass, gauze etc with sash bar any number fitted with cut and mitered beads for securing glass gauze etc , sizes of members of shutters as specified in SSR Part I section 8, Section 8.24(a), supplied and fitted to chowkats complete all as specified and as directed. |
| 57 | Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed |
| 58 | Sheet glass 3mm thick ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm in each pane, all as specified and as directed. |
| 59 | Figured glass 3mm thick pin head type and glazing with oil putty in squares not exceeding 0.5 sqm in each pane complete all as specified and as directed. |
| 60 | 75mm long mild steel butt hinges medium weight cold rolled complete all as specified and as directed |
| 61 | 75mm long hasp and staple, aluminium anodized, including bolt to hinge plate and fixed with screws complete all as specified and as directed |
| 62 | Providing second class hard wood lipping 12 mm wide fixed with nails complete all as specified and as directed. |
| 63 | 12mm thick pre-laminated particle board interior grade ,one side laminated with decorative choice and other side balancing white lamination ,fixed with screws to timber frames work for shutters of ward robes ,cabinets etc, complete all as specified and as directed. |
| 64 | 200mm long aluminum anodised barrel tower bolts of extruded section and fixed complete all as specified and as directed. |
| 65 | 100 mm long butt hinges medium weight cold rolled steel, complete all as specified and as directed. |
| 66 | 125mm long extruded aluminum alloy handles, fabricated type, bow handle, complete all as specified and as directed. |
| 67 | Plain Cement concrete 1:2:4, type B1 (using 20mm graded agg) for hold fasts finished to match with the sorrounding surfaces including necessary form work complete all as specified and as directed. |
| 68 | Precast cement concrete blocks masonry with grade 1:3:6 Type C1 solid blocks exceeding 10 cm in width having minimum compressive strength of 50 Kg/Sqcm as per IS-2185 (part-I)2005 and set in CM 1:6 complete all as specified and as directed. |
| 69 | Rendering 15mm thick in CM (1:6) on stone masonry surfaces or surface other than fair face of brick work, finished even and smooth with out using extra cement complete all as specified and as directed. |
| 70 | Rendering 5mm thick in CM (1:3) on fair faces of brick work or concrete surfaces, finished even and smooth with out using extra cement on ceiling surfaces complete all as specified and as directed. |
| 71 | Rendering 15mm thick in CM (1:4) on stone masonry surfaces or surface other than fair face of brick work, with approved water proofing compound finished fair & even without using extra cement complete all as specified and as directed. |
| 72 | Rendering, 15mm thick, on fair faces of brick work or concrete surfaces in CM (1:6) finished even and smooth without using extra cement complete all as specified and as directed. |
| 73 | Supply only liquid water proofing compound complete all as specified and as directed. |
| 74 | Preparation of new surfaces and applying three coats of white wash on walls complete all as specified and as directed. |
| 75 | Preparation of new plastered surfaces on walls and applying two coats of cement based paint over a priming coat, complete all as specified and directed. |
| 76 | Preparation of new plastered surfaces on walls and applying two coats of oil bound distemper over a coat of primer, complete all as specified and as directed. |
| 77 | Preparation of new wooden surfaces of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 78 | Plain cement concrete type B0 1:2:4 (12.5 mm graded stone aggregate) as in copings, plinth courses, string courses and the like including weathering, slightly rounded or chamfered angles and throating, complete as apecified and directed. |
| 79 | Preparation of new steel and iron surfaces of any description, over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed. |
| 80 | Precast reinforced cement concrete 1:2:4 type B1 using 20mm graded stone aggregate for cover slab set in CM 1:6 including necessary form work, complete all as specified and as directed.. |
| 81 | Curtain rails, anodised aluminium alloy with fixing brackets,stops, rollers etc complete all as specified and as directed. |
| 82 | Tubular towel rail, Brass chromium plated 20mm dia, D type, 60cm long between flanges Add if fixed in repairs complete all as specified and as directed. |
| 83 | Floor door stopper of 150mm aluminiumalloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, complete all as specified and as directed. |
| 84 | 12mm thick Plywood,grade BWR type BB fixed with nails to timber frame work, all as specified and directed. |
| 85 | Grating doom 125 mm dia with waste hole of PTMT(Minimum weigh 40 gms), complete all as specified and as directed. |
| 86 | Blank |
| 87 | Vitreous china white soap dish approximate size 160x160x90mm embeded in the wall, complete all as specified and as directed. |
| 88 | Plastic water closet seat, black, closed Pattern with flat bottom, and Cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed. |
| 89 | PVC (SWR) 'P' trap 125/110mm bore complete all as specified and as directed. |
| 90 | PVC (SWR) 'S' trap 125/110mm bore complete all as specified and as directed. |
| 91 | Aluminum alloy,anodised sliding door bolts,of 300mm long with hasp and staple(bolt type) and fixing clips of sheets ,cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed complete as specified and directed. |
| 92 | Stainless Steel Plate rack of 750mmX750mm as per sample kept in GE office fixed in repairs, complete all as specified and as directed. |
| 93 | Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub structure to a depth of 300 mm including excavating channel along the wall and rodding etc, complete all as specified and as directed. |
| 94 | Treatment of soil under existing floors using emulsion @ one litre per hole, 300 mm apart including drilling and plugging 12 mm dia holes with cement mortar 1:2 (1 cement : 2 coarse sand ) to match the existing floors, complete all as specified and as directed. |
| 95 | Antitermite Treatment along the external wall below concrete or masonary apron using chemical emulsion @ 2.25 litre per linear metre including drilling and plugging holes etc in apron, complete all as specified and as directed. |
| 96 | Plain cement concrete 1:3:6 type C2(using 40mm graded aggregate), 75 mm thick as in plinth protection, complete all as specified and as directed. |
| 97 | Plain Cement concrete type D-2 (using 40mm graded aggregate) 75 mm thick as in sub base, complete all as specified and as directed. |
| 98 | Machine pressed precast concrete interlocking paver block any shape and size conforming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement and pigment, laid dry over and including 30mm thick sand cushioning all as specified and directed. |
| 99 | Providing pre-cast concrete, type C-1 1:3:6 (using 20mm graded aggregates) in CM 1:6 as in kerb stone, complete all as specified and as directed. |
| 100 | Blank |
| 101 | M&L cutting and grinding roundings chamfering of exposed edges of Kota stone slab as in treades of steps all as directed. |
| 102 | M&L for rendering 10mm thick in CM 1:6 on cement concrete or block masonry surface finished even and smooth wihout using extra cement all as specified as in risers of steps. |
| 103 | SCHEDULE A PART II (E/M Works)Schedule A Part II E/M Works : Taking down old aluminium point wiring of 1.5/2.5/4.0 sqmm cables complete along with TW Batten/PVC conduit and making good disturbed surfaces of walls, floors etc all as directed by Engg-in-charge. |
| 104 | Taking out old/existing MCB DB SPN/TPN including MCBs of diffirent capacity complete by disconnecting them all as specified and as directed. |
| 105 | Point wiring complete with 2 runs of 1.5 sqmm single core, PVC insulated, unsheathed cable 1100 volts grade, multi stranded copper conductor drawn into PVC conduit and accessories concealed in wall, roof etc., and including provision of one run of PVC insulated 1.5 sqmm copper conductor for earth continuity and connected to common earth dolly and pressed steel terminal boxes made out of 1.6mm thick MS sheet concealed in wall and laminated sheet cover of 3mm thick on top for housing the switches,fan regulator socket, outlet etc, all complete for the following as specified and directed by Engineer-in-Charge :- |
| 106 | One light point controlled by one one way 5 Amp switch complete all as specified and as directed. |
| 107 | One ceiling Fan point controlled by one 5 Amp switch and regulator complete all as specified and as directed. |
| 108 | One exhaust Fan point controlled by one 5 Amp switch complete all as specified and as directed. |
| 109 | One 5 pin socket out let 05 Amps on independent board complete all as specified and as directed. |
| 110 | All as per Item No 104 here-in-before, but using 2.5 sqmm, copper conductor with 1.5 sqmm, PVC insulated, single core cable for earth continuity conductor for 15 Amps S/S comb.Note for item No 103 & 105 Cost element for cutting chases in walls for concealed point wiring and making good using CM 1:4 shall be deemed to be included in quoted rate and no extra claim shall be entertained. |
| 111 | Celing rose, 03 terminals, surface bakelite, fixed to wall/ceiling complete all as specified and as directed. |
| 112 | Switch piano type single pole 5 amps one way flush type complete all as specified and as directed. |
| 113 | Switch socket combination 2 in 1, 5 amps flush type complete all as specified and as directed. |
| 114 | Switch socket combination 2 in 1, 3 Pin 5 Amps and 15 amps flush type universal complete all as specified and as directed. |
| 115 | MCB SP series 6 Amps to 32 Amps 240 volts complete all as specified and as directed. |
| 116 | Ceiling fan (white in colour 5 star rating) complete with accessories 230V SP 1200mm sweep ISI marked, complete all as specified and as directed. |
| 117 | Stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and as directed. |
| 118 | Exhaust fans AC single phase 230/240 V of size 300 mm sweep with louver in including provision of necessary walls opening and cementing work all as specified and directed. |
| 119 | MCB, DB TPN 4 way with suitable rated bus bar double door 415 Volts with IP-43 protection complete all as specified and as directed. |
| 120 | MCB, DB SPN 8 way with suitable rated bus bar double door 240 Volts with IP-43 protection, complete all as specified and as directed. |
| 121 | MCB TPN 415 volts 63 amps with 10KA breaking capacity, complete all as specified and as directed. |
| 122 | MCB SPN 32 Amps 240 volts 32 amps with 10KA breaking capacity, complete all as specified and as directed. |
| 123 | Sub main wiring complete with 2 runs of 4 sqmm, single core, PVC insulated, unsheathed FRLS cable,1100 volts grade,multi stranded with copper conductor, drawn through and including PVC conduit of 20mm dia pipe with one run of PVC insulated, 4 sqmm FRLS cable, copper conductor for earth continuity conductor all as specified and as directed.(For backup to solar water heater)Note: 2 runs of 4 Sqmm single core copper conductor, one run of 4 sqmm copper conductor earth wire and PVC conduit and its accessories will be measured as one unit. |
| 124 | LED batten luminaire surface mounted, 4 feet system wattage of 19/20 Watts with lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 3KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, SDCM<5, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 Degree C, system efficacy at luminaire level ≥ 100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed. (Make-Philips of Catalogue No. BN108 C LED 20S PSU CDL WH, Wipro Catalogue No. LE10-251-XXX-57SLRL, Bajaj Catalogue No. BLTRU 20W WH VIVA). Note: - Refer instructions carefully for LED light fittings mentioned in Item No 110 |
| 125 | Note : For item No 119:- (i) The LED lights/luminaries supplied must meet the provision laid down in IS No.16101, 16102 Part I & II, 16103 Part I, 15885 Part II/ Sec 13, 16104, 16105, 16106, 16108:2012 and LM 70. (ii) All LED light products must have replacement warranty of 50,000 hours from the date of completion of the contract. (iii) The product will replace free of cost in the following cases:-(a) Manufacturing defects.(b) Failure due to mechanical and electrical impact.(c) Drop in lumen (or lux at 1m) below 90% of claimed values of lumen (or lux at 1m) of the LED/Luminaries. (iv) The warranty will be provided on a case to case basis and shall be extended if above clause are included in contract agreement/supply order.(v) The firm must have all India foot print, its own R&D and should be a leading manufacturer of LED lights/luminaries.(vi) The contractor shall submit the following certificates from the manufacturer for LED light fittings (both light and driver)(a) Surge protection certificate.(b) Type test certificate LM-79, LM-80 for all luminaries along with detailed technical Catalogue duly signed and sealed by the manufacturer. (vii) Owing to continuous innovation and improvements in LED light fittings by manufactures the contractor shall provide latest version of LED fittings with high lumens output and system efficacy which are available in the market during execution of works.(viii) For any change in product or change in catalogue number etc due to technological up gradation letter has to obtain from the lighting company on their letter head signed by an official of National level only. (ix) All the LED fittings shall be identified by printing or fixing stickers duly mentioned the CA number and date of completion. (x) Sample approval must be obtained for any type of LED Light fittings before incorporating in works. |
| 126 | BLANK |
| 127 | Supply, Install, Testing and Commissioning of 'Solar Hot Water System' (Flat Plate Collector) based on indirect transfer of heat of capacity 100 LPD with electrical back up of 2 KW capacity including make up water tank and mild steel frame work complete all as specified and as per manufacturer's instructions . |
| 128 | Cutting existing 50/40 mm dia GI pipe line and inserting Tee of suitable size for connection of 25 mm dia GI pipe complete all as specified and as directed. |
| 129 | 25 mm bore tubing galvanized, “Medium class”, supplied and laid complete including fittings.(for incoming supply to solar water heater) complete all as specified and as directed. |
| 130 | 15mm bore hot water pipe duly insulated with glass wool and aluminium cladding (for hot water supply from solar water heater to bathroom) complete all as specified and as directed. |
| 131 | BLANK |
| 132 | 25mm dia Gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and as directed. |
| 133 | BLANK |
| 134 | BLANK |
| 135 | BLANK |
| 136 | BLANK |
| 137 | BLANK |
| 138 | BLANK |
| 139 | BLANK |
| 140 | BLANK |
| 141 | BLANK |
| 142 | BLANK |
| 143 | BLANK |
| 144 | BLANK |
| 145 | BLANK |
| 146 | Sypply and laid in trenches Galvanised Iron pipe 80mm dia light grade with all required necessary fittings laid in trenches complete in protection of HT/LT cables at road crossing complete all as specified and as directed. |
| 147 | BLANK |
| 148 | BLANK |
| 149 | BLANK |
| 150 | BLANK |
| 151 | BLANK |
| 152 | BLANK |
| 153 | BLANK |
| 154 | BLANK |
| 155 | BLANK |
| 156 | Anti-climbing device, spikes type fabricated out of MS bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and as directed. |
| 157 | BLANK |
| 158 | Excavating in trenches not exceeding 1.5mtr wide and not exceeding 1.5mtr in depth for foundation etc or for shafts, wells cesspits, manholes, pier holes, etc. not exceeding 10 Sqmm on plan and not exceeding 1.5mtr in depth and getting out in hard/dense soil complete all as specified and as directed. |
| 159 | Excavating in trenches n.exc 1.5mtr wide and beyond 1.5 mtr in depth for foundation etc or shafts, wells cesspits, manholes, pier holes, etc. n. exc 10 Sqmm on plan and not exc 1.5m in depth and getting out in hard/dense soil. |
| 160 | Returning, filling in, including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick in soft/dense soil complete as specified and directed. |
| 161 | Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point in soil, complete as specified and directed. |
| 162 | BLANK |
| 163 | Providing Plain cement concrete 1:3:6 type C1 using 20mm graded stone aggregate as platform mass concrete, coping to pole for embedding stay rods all specified including necessary from work and applying two coats of cement based paint on coping platform etc, whereever required all as directed. |
| 164 | Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.3mm thick burried directly in ground earth pit not less than 2.25 mtr deep below normal ground level with the top edge of earth plate at a depth of not less than 1.5mtr below normal ground level connected to GI earth strip 32x6mm as earth lead by means of bolts, nuts, check nuts and washers made out of GI and GI strip protected by 40mm bore light grade GI pipe as well as 20mm dia medium grade pipe 1.5 mtr fixed with funnel and wire mesh as specified and connected all as shown in electrical plat No 3 of SSR Part I including necessary earth work and excavation in any type of soil and PCC 1:2:4 type B1 in chamber and 40mm thick RCC 1:2:4 type B1 cover slab with 6mm dia mild steel bars at 100mm centre to centre both ways with 6mm dia MS hooks complete all as specified. The GI earth strip & 40mm dia bore light grade GI pipe upto 7.5M deemed to be included in the rate quoted by the contractor. Beyond 7.5mm GI earth strip dia and GI tubing light grade 40mm dia shall be measured and paid under the respective item of schedule (for transformer, GOD, Panel bd and APFC Panel) Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |