| Sl. No. | Item Description |
| 1 | Demolishing plain cement concrete manually/ by mechanical means including disposal of material within 50 metres lead complete all as specified and directed. |
| 2 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead complete all as specified and directed. |
| 3 | Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually/ by mechanical means including stacking of serviceable and disposal of unserviceable material within 50 metres lead complete all as specified and directed. |
| 4 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead of area 3 sq. metres and below complete all as specified and directed. |
| 5 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead for thickness of tiles 7 mm to 25 mm complete all as specified and directed. |
| 6 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead complete all as specified and directed. |
| 7 | Dismantling G.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge , 15 mm to 50 mm nominal bore complete all as specified and directed. |
| 8 | Dismantling of flushing cistern of all types (C.I./PVC/Vitreous China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead complete all as specified and directed. |
| 9 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead complete all as specified and directed. |
| 10 | Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level complete all as specified and directed. |
| 11 | Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba complete all as specified and directed. |
| 12 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead complete all as specified and directed. |
| 13 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead 100 mm dia pipe complete all as specified and directed. |
| 14 | Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead complete all as specified and directed. |
| 15 | M&L for Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth complete all as specified and directed. |
| 16 | M&L for Stone work in plain ashlar in super structure upto floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) including pointing with cement mortar 1:2(1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : Red sand stone complete all as specified and directed. |
| 17 | M&L for Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) complete all as specified and directed. |
| 18 | M&L for use and waste of form work including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges complete all as specified and directed. |
| 19 | M&L for Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more complete all as specified and directed. |
| 20 | M&L for pressed steel door frames conforming to IS: 4351 manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile B Fixing with adjustable lugs with split end tail to each jamb complete all as specified and directed. |
| 21 | M&L for Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works complete all as specified and directed. |
| 22 | M&L for 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, including (Door handle, lock , stopper & DRDO logo etc) complete all as specified and directed. |
| 23 | M&L for Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, (Glazing, panelling and dash fasteners to be paid for separately) for fixed portion , Powder coated aluminium (minimum thickness of powder coating 50 micron) complete all as specified and directed. |
| 24 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, . (Glazing, panelling and dash fasteners to be paid for separately) : Powder coated aluminium (minimum thickness of powder coating 50 micron) complete all as specified and directed. |
| 25 | Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, complete all as specified and directed.Note : (Only weight of grill to be measured for payment) |
| 26 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc, With stainless steel cover plate minimum 1.25 mm thickness complete all as specified and directed. |
| 27 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. Pre-laminated particle board with decorative lamination on both sides complete all as specified and directed. |
| 28 | Providing and fixing 19 mm thick both side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand boxes, shelves, racks, Almira, cupboard and drawer etc. including necessary nails, screws etc. complete all as specified and directed. |
| 29 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm) complete all as specified and directed. |
| 30 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) complete all as specified and directed. |
| 31 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors complete Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides complete all as specified and directed. |
| 32 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with well matched teak three ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. Fixing with hinges of required size and necessary screws 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws complete all as specified and directed. |
| 33 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, complete all as specified and directed. |
| 34 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent complete all as specified and directed. |
| 35 | Providing and laying Glazed Vitrified tiles Matt/Antiskid finish Size of Tile 600 x 600 mm, 10 mm thick with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, levelling system and rubber mallet for placing the tiles gently and easily complete all as specified and directed. |
| 36 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete all as specified and directed. |
| 37 | Providing and laying Double charge vitrified tile polished finish of Size of Tile 600 x 1200 mm, 10 mm thick with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, levelling system and rubber mallet for placing the tiles gently and easily complete all as specified and directed. |
| 38 | Providing and laying Size of vitrified Tile 1000x1000 mm, 10 mm thick with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete all as specified and directed. |
| 39 | Providing and fixing up to floor five level precast cement concrete solid block masonry, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete : 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) complete all as specified and directed. |
| 40 | M&L for Pre-cast cement concrete block masonry type C1 (1:3:6) 20 mm graded stone aggregate with solid blocks, 10 cm in width and setting in mortar CM 1:4, complete all as specified and directed. |
| 41 | M&L for 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand) complete all as specified and directed. |
| 42 | M&L for 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand) complete all as specified and directed. |
| 43 | M&L for 12 mm cement plaster on ceilings finished with a floating coat of neat cement of mix : 1:3 (1 cement: 3 fine sand) complete all as specified and directed. |
| 44 | M&L for pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) : Flush/ Ruled pointing complete all as specified and directed. |
| 45 | M&L for complete removal of existing treatment by scrapping with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 grit having dia of 7'/9' to make the surface free from dust loose paint etc, by skilled labour complete all as specified and directed. |
| 46 | M&L for single component polymer modified repair mortar with compressive strength minimum 38 MPA at 28 days (ASTM C 109:99) and tensile strength minimum 2.5 MPA (ASTM C 307) up to 15mm in a single coat @ 34 Kg per Sqm for 15mm thickness as per manufacturer instructions complete all as specified and directed. |
| 47 | M&L for water proof cement based putty @ 1kg (undiluted) per sqm of average thickness 1mm over the plastered / old painted wall after scrapping to prepare the surface even and smooth complete and sanding of the putty surface with mechanical wall sander (having mechanical vacuum mechanism) having RPM not less than 1500 sanding pad of 240 Grit or above to make the surface free from dust etc by skilled labour as per following steps complete all as specified and directed.Step 1 :- Mix the putty powder by adding water as per manufacturer instructions and mix it with putty mixer with the mixing capacity of min 2.5 kg putty per minute.Step 2 :- Apply the first coat the prepared mixer with the help of fully automatic airless spray machine of putty application having flow speed of max 6 ltrs per minutes with a maximum pressure 3300 PSIStep 3 :- Allow 6-8 hrs time to dry the putty surface. |
| 48 | M&L for one coat of acrylic water based interior grade primer @0.8 ltr (undiluted)/10 Sqm diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 litre per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface for painting of subsequent coats, complete all as specified and directed. |
| 49 | M&L for applying two coats of oil bound distemper using airless spray technology with max material hose length of 30 mtr the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surface complete all as specified and directed.Note:- Sanding of surface to be done by mechanical sander with 1500-2700 rpm with internal dust extraction system for clean environment certified by paint manufacturer. |
| 50 | M&L for two coats of smooth interior acrylic emulsion with rich matt finish having VOC less than 50 grams per ltr complying LEEDS criteria @1 Ltrs (undiluted)/ 10 Sqm diluted with water in 2:1 ratio applied over priming coat with fully automatic airless spray machine of paint application with a flow speed of minimum 1 litre per minute having a pressure of 3300 PSI. Allow 6-8 hrs dry the surface in both the coats of paints as per manufacturer instructions, complete all as specified and directed. |
| 51 | M&L for preparation of new plastered surface of walls and applying two coats of oil bound distemper using airless spray technology with max working pressure of 3300 PSI and capable of operating single spray gun with a max material hose length of 30 mtr the spray machine should be of reputed manufacture with pro quard technology and capability of tracking pressure and paint usage and certified by pain manufacturer and as mentioned in PS and accessories for applying distemper should be able to spray in hard to reach areas and penetration of distemper on the surfaces, complete all as specified and directed.Note:- Sanding of surface to be done by mechanical sander with 1500- 2700 rpm with internal dust extraction system for clean environment certified by paint manufacturer. |
| 52 | M&L for one coat of acrylic water based exterior grade primer @ 0.9 ltr (undiluted)/10 Sqm diluted with water in 1:1 ratio to be applied with fully automatic airless spray machine of paint application with a flow speed of min 1 litre per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface for painting of subsequent coats, complete all as specified and directed. |
| 53 | M&L for two coat of water based premium acrylic smooth exterior emulsion of approved colour with silicon additive & colour stay Technology, Excellent Dirt pick up resistance with low VOC less than 50 grm/ Ltr as per the LEEDS specifications anti algal properties in two coats @ 1.79 ltr (undiluted)/ 10 Sqm diluted with water as per manufacturer instructions applied over priming coat with fully automatic airless spray machine of pain application with a flow speed of minimum 1 litre per minute having a pressure of 3300 PSI. Allow 6-8 hrs dry the surface in both the coats of paints as per manufacturer instructions, & all as specified and directed. |
| 54 | M&L for preparing old plaster/ concrete/stone surfaces of walls by brooming down or steel wire brushing, scrapping down smoke soof, moulds, moss and efflorescent salts and trading oil and greasing spots and applying one coat of water base paint (exterior emulsion) & complete all as specified and directed. |
| 55 | M&L for preparation of new plastered surfaces of wall and applying two coats of cement base paint over one coat of primer complete all as specified and directed. |
| 56 | M&L for preparing old plaster/ concrete/stone surfaces of walls by brooming down or steel wire brushing, scrapping down smoke soof, moulds, moss and efflorescent salts and trading oil and greasing spots and applying one coat of cement base paint complete all as specified and directed. |
| 57 | M&L for Painting on Wooden surfaces with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : New work (two or more coats) including a coat of approved wood primer but excluding a coat of mordant solution complete all as specified and directed. |
| 58 | M&L for painting Steel work with Deluxe Multi Surface Paint to give an even shade. New Work Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture complete all as specified and directed. |
| 59 | M&L for painting on Old Wooden Surfaces with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Old work (one or more coats) complete all as specified and directed. |
| 60 | M&L for painting on Old Steel Surfaces with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Old work (one or more coats) complete all as specified and directed. |
| 61 | M&L for Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: One or more coats on old work complete all as specified and directed. |
| 62 | M&L for finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete on Concrete work complete all as specified and directed. |
| 63 | Providing and fixing in repairs white vitreous china extended wall mounting water closet of approved shape including providing & fixing PVC flushing cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), Including Flush plate, including soft closing seat cover, and cistern fittings, nuts, bolts and gasket etc complete all as specified and directed. |
| 64 | Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litre with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete all as specified and directed. |
| 65 | Providing & fixing White vitreous china water closet squatting pan (Indian type) along with \\"S\\" or \\"P\\" trap including dismantling of old WC seat and \\"S\\" or \\"P\\" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba. Long pattern W.C Pan of size 580x440 mm complete all as specified and directed. |
| 66 | Providing and fixing in repairs Oval shape wash basin with 15 mm dia CP Brass single hole basin mixer of approved quality and make, including cutting and making good the walls wherever required:- White Vitreous China Oval Shape Wash basin size 550x400 mm or equivalent with a 15 mm CP Brass single hole basin mixer complete all as specified and directed. |
| 67 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make, complete all as specified and directed. |
| 68 | Providing and fixing in repairs Vitreous China Urinal, Half stall type,white including CP Waste Coupling 32 mm, flush pipe, CP Urinal Spreader and waste pipe complete all as specified and directed. |
| 69 | Providing and fixing in repairs white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required, Size 600x450x200 mm or equivalent complete all as specified and directed. |
| 70 | Providing and fixing in repairs Stainless Steel grade 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm complete all as specified and directed. |
| 71 | S&F 40 mm dia Low density polyethylene pipes (LDPE) of pressure rating 6 kgf/Sqcm fixed complete to walls, ceilings or in floors etc complete all as specified and directed. |
| 72 | Providing and fixing in repairs mirror of superior glass (of approved quality) and of required shape and size with bevelled edge of approved make and shade Rectangular shape 1500x450 mm complete all as specified and directed. |
| 73 | S&F 600 mm long towel rail in repairs with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms complete all as specified and directed. |
| 74 | Providing and fixing in repairs Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints Exposed on wall 25 mm nominal dia Pipes complete all as specified and directed. |
| 75 | Providing and fixing in repairs Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints, Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes complete all as specified and directed. |
| 76 | Providing and fixing in repairs C.P. brass bib cock of approved quality conforming to IS:8931, 15 mm nominal borecomplete all as specified and directed. |
| 77 | S&F in repair CP fancy type Angular Stop Cock 15 mm dia with wall flange complete all as specified and directed. |
| 78 | Providing and fixing in repairs uplasticised PVC connection pipe with brass unions: 45 cm length 15 mm nominal bore complete all as specified and directed. |
| 79 | Providing and fixing in repairs gun metal gate valve with C.I. wheel of approved quality (screwed end): 25 mm nominal bore complete all as specified and directed. |
| 80 | Providing and fixing in repairs CP grating of approved quality and colour. Circular type 100 mm nominal dia complete all as specified and directed. |
| 81 | Providing and fixing in repairs factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat Frame size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/Sqmm, modulus of elasticity 900 N/Sqmm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete all as specified and directed. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 82 | Providing and fixing in repairs factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter 30 mm thick. comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/Sqmm, modulus of elasticity 850 N/Sqmm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) |
| 83 | Providing and fixing Fancy type Stainless Steel Heavy Duty sliding door bolts, ISI marked , with nuts and screws etc. complete : 300x16 mm complete all as specified and directed. |
| 84 | Providing and fixing Fancy type Stainless Steel Heavy Duty tower bolts, ISI marked, with necessary screws etc. complete: 200x10mm complete all as specified and directed. |
| 85 | Providing and fixing Fancy type Stainless Steel Heavy Duty tower bolts, ISI marked, , with necessary screws etc. complete: 100x10mm complete all as specified and directed. |
| 86 | Providing and fixing chromium plated brass handles with brass screws etc. complete: 100 mm complete all as specified and directed. |
| 87 | Providing and fixing chromium plated brass handles with brass screws etc. complete : 125 mm complete all as specified and directed. |
| 88 | S&F 150 mm size Fancy type Stainless Steel Heavy Duty handles with SS screws etc, complete all as specified and directed. |
| 89 | Providing and fixing in repairs SS Toilet Roll Holder complete all as specified and directed. |
| 90 | S&F in repairs CP brass Health Faucet Spray with 1 mtr long Easy Flex Tube in Chrome Finish & Wall Hook complete all as specified and directed. |
| 91 | Providing and fixing in repairs 100 mm sand cast Iron grating for gully trap complete all as specified and directed. |
| 92 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors: 100 mm inlet and 100 mm outlet Sand cast iron S&S as per IS: 3989 complete all as specified and directed. |
| 93 | Providing and fixing IS: 12817 marked stainless steel butt hinges with stainless steel screws etc. complete: Each 125x64x1.90 mm complete all as specified and directed. |
| 94 | Providing and fixing in repairs factory made solid Foam uPVC profile for cabinet frame (45 x 20 mm) of approved shade, quality and make. The profile shall be laminated on both sides, made from rigid foam sheets (Single extruded) having density 600 Kg/cum and the exposed edges sealed with PVC edge beading of same shade and colour. The frame shall be fire retardant with necessary screw holding capacity. Frame shall be fixed to wall using Expendable Fastener with necessary stainless steel screws, complete all as specified and directed. |
| 95 | Providing and fixing in repairs factory made Cabinet Shutter/Partition 20 mm nominal thickness of approved shade, quality and make, made from rigid foam sheets (Single extruded) having density 600 Kg/cum and laminated on both side by laminate Sheet/PVC foil lamination. The exposed edges shall be sealed with PVC edge beading of same shade and colour. The shutter shall be fire retardant having necessary screw holding capacity. Shutter shall be fixed to frame using approved hinges with necessary stainless steel screws, complete all as specified and directed. |
| 96 | S&F Stainless Steel Cabinet Hinges, Soft Close, Clip On 3D, 4 Hole Full Overlay, Suitable for 14-20 mm Thick Panel, 105° Opening, Wardrobe, Kitchen, Bathroom with 1 Year Warranty fixed with screws complete all as specified and directed. |
| 97 | S&F Stainless Steel Cupboard locks with 2 Keys , for Cupboards, wardrobes, Cabinet furnitures & Electrical Panel, Suitable for Panels Upto 25 mm of Thickness complete all as specified and directed. |
| 98 | M&L 2nd class hard wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Kiln seasoned and chemically treated hollock wood complete all as specified and directed. |
| 99 | Providing and fixing in repairs brass curtain rods of wall thickness 1.25 mm with two brass brackets fixed with brass Sqm screws and wooden plugs etc. wherever necessary, 25 mm diameter complete all as specified and directed. |
| 100 | S&F 100% Blackout Roller Blinds for Windows UV Protection, Waterproof, Room Darkening, Corded Roll Up and Down Blinds for Office Customizable any colour, rectangular shape. Fabrics of Roller blinds shall be made up of either 100% polyester finished with an acrylic coating or a combination of polyester and acrylic. Materials covers various fabrics: plain knitted fabrics, designs in woven jacquard fabrics. Room-darkening blinds consist of an acrylic coating on both sides of the vanes shutting out much light and direct harsh sunlight. Equipped with corded chain and aluminium top and bottom rod with a safety device to lock the chain to the wall so that it does not stay loose complete all as specified and directed. |
| 101 | Providing and fixing Stainless Steel floor door stopper, ISI marked, with necessary screws etc. complete Twin rubber stopper complete all as specified and directed. |
| 102 | Providing and placing on terrace (at all floor levels) White Colour triple Layer polyethylene water storage tank, IS: 12701 marked, with Ltr cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank (1000/500 ltr Capacity Tank) complete all as specified and directed. |
| 103 | Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) complete all as specified and directed. |
| 104 | Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc same, complete all as specified and directed. |
| 105 | M&L for cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc complete all as specified and directed. |
| 106 | Hacking of CC flooring including cleaning for surface etc. complete all as specified and directed. |
| 107 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) complete all as specified and directed. |
| 108 | M&L for 12 mm cement plaster finished with a floating coat of neat cement of mix : 1:3 (1 cement: 3 fine sand) mixed with water proofing compound (Water proofing compound shall be paid for separately) complete all as specified and directed. |
| 109 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers complete all as specified and directed. |
| 110 | M&L for water proofing roof treatment consisting of :-(i) Surface preparation : The surface to be treated should be sound and free from all types of dirt, dust and debris. Clean surface by brushing, scraping or chipping to eliminate all defective materials and foreign matter. Proper surface preparation needs dry mechanical grinding to expose base Substrate. Making of angle fillets(75mm*75mm) all around the periphery of the wall with polymer modified mortar using SBR Latex Plus.(ii) Construction joints : All construction joints and cracks >1mm shall be treated by cutting V groove and filling with polymer modified SBR Latex and reinforced with geotextile membrane dipped in PU liquid Membrane before the 1st coat application.(iii) Water proofing membrane : S&F Waterproofing membrane: Supplying and applying water-based ,single component UV resistant elastomeric PU liquid membrane coating applied with brush/roller having SRI >109 with an elongation of >400% and tensile strength of 1.4 MPa as per ASTM D 412, 80 % Solid Content, shore A Hardness of min. 50 as per ASTM D 2240. The system includes final base preparation as per note given below, applying approved membrane coating in three coats at 2.8 kg per Sqm providing 1.5 mm DFT , complete as per Manufacturer specifications. Waterproofing membrane to be terminated on parapet wall in a V groove of size 25 mm x 25 mm at least 300 mm above FFL which should be sealed with Polymer Mortar. The application will be executed by company authorised applicator upon verification from the company complete all as specified and directed. |
| 111 | Providing and fixing in repairs soil, waste and vent pipes :100 mm dia Sand cast iron S&S pipe as per IS: 172 complete all as specified and directed. |
| 112 | Providing and fixing in repairs soil, waste and vent pipes 75 mm diameter, Sand cast iron S&S pipe as per IS: 1729 complete all as specified and directed. |
| 113 | Providing and fixing in repairs on wall face unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A. Rm including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion, Single socketed pipes, 110 mm diameter complete all as specified and directed. |
| 114 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion, Coupler 110 mm complete all as specified and directed. |
| 115 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion, Bend 87.5° 110 mm bend complete all as specified and directed. |
| 116 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement: 4 coarse sand) and making good the wall etc. complete. 110 mm complete all as specified and directed. |
| 117 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams complete all as specified and directed. |
| 118 | Providing and fixing in repairs tiled false ceiling of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, and as directed by Engineer-in-charge with GI Metal Ceiling Lay in perforated Tegular edge global white colour tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece complete all as specified and directed. |
| 119 | M&L for Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete: 1 With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration complete all as specified and directed. |
| 120 | M&L for post constructional ATT along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.: 2.35.2.1 With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration complete all as specified and directed. |
| 121 | M&L for Anti-termite Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration complete all as specified and directed. |
| 122 | M&L for Anti-termite Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration complete all as specified and directed. |
| 123 | M&L for Anti-termite Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same complete all as specified and directed. |
| 124 | M&L for cleaning the sand stone surface and removing dirt, dust, bird dropping, grease, oil, algae, fungus, monkey beats, vegetable growth etc., including providing, applying and washing the surface with liquid Ammonia Chemical of 5% solution and other chemical cleaning agent as approved by Archaeological Survey of India/ Engineer-in-charge, of approved brand and manufacturer, with the help of required scrubbers and also cleaning with machine operated water jet mixed with desired quantity of fine silica where ever required, without causing any scratching/ damage to the stone surface and finally washing the surface with clean water with the help of pressure jet machine, complete in all respect, including taking all precautions to safeguard ventilators, windows, doors etc. by suitable covering so as to avoid any damage to the building/ structure, all as per direction of Engineer-in-charge |
| 125 | Excavating holes more than 0.10 cum & upto 0.5 cum including getting out the excavated soil, then returning the soil as required in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering etc, disposing of surplus excavated soil, as directed within a lead of 50 m and lift upto 1.5 m in all kinds of soil complete all as specified and directed. |
| 126 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) complete all as specified and directed. |
| 127 | M&L for Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. h finished welded type tubes complete all as specified and directed. |
| 128 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required complete all as specified and directed. |
| 129 | Providing and fixing hard drawn steel wire fabric 75x25 mm mesh of weight not less than 7.75 Kg per sqm welded to angle iron frame includigng priming coat with approved steel primer all complete all as specified and directed. |
| 130 | Providing and fixing Brass 100 mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete all as specified and directed. |
| 131 | Providing and fixing 6 mm thick Aluminium Composite Panel fixed in aluminium doors and partition frames with EPDM rubber / neoprene gasket etc. (Cost of aluminium snap beading shall be paid in basic item) complete all as specified and directed.MCP (Metal Composite Panel) Product Description(a) Panel Thickness 6 mm(b) Top/Bottom Aluminium Sheet 0.25 mm(c) Core Thickness 5.5 mm(d) Core Type LDPE(e) Minimum Weight 6.8 Kg/Sqm |
| 132 | M&L for taking down and removal of loose / disintegrated old concrete / plaster and applying average 15mm thick bonding coat of modified styrene butadiene Emulsion (SBR Bonding agent ) in proportion 1 (SBR Bonding agent ) : 1(water) : 3 (OPC) by volume with the brushes etc to bind New Cement plaster/ polymer Modified plaster/ concrete/ screed concrete with old surface etc complete all as specified and directed. |
| 133 | M&L and applying two coats of 2 component zinc based epoxy rust preventer on corroded reinforcement after cleaning and removing the rust from corroded reinforcement with the help of wire brush and treating it with rust remover including thoroughly cleaning washing air blowing brushing etc complete and applying as per manufacture's instructions complete all as specified and directed. Note : (i) Qty of Zinc based epoxy rust preventer only shall be taken into account for payment purpose on the basis of actual consumption. |
| 134 | Providing and casting and repairing the damage concrete portion by using superfluid dual shrinkage compensated structural grade M40 Microconcrete including providing, applying, finishing, curing etc complete all as specified and directed. |
| 135 | M&L for applying average 10mm thick plaster with polymer modified mortar fortified with SBR (Nitobond SBR 45 ) in proportion 1:3 (cement & sand) with mixing Nitobond @ 5 litres/Bag of cement, finished surface to match with existing adjoining surface of ceiling, Chajjas, facia, beams and alike complete all as specified and directed. |
| 136 | M&L for laying/covering top of membrane with Geotextile, 120 gsm non woven, 100% polyester of thickness 1 to 1.25 mm bonded to the membrane with intermittent touch by heating the membrane by Butane Torch as per manufactures recommendation etc complete all as specified and directed. |
| 137 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc laying of cable & pipes, not exceeding 10 sqm on plan and getting out in soft/loose soil complete all as specified and directed. |
| 138 | Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) upto 200 mm bore set in cement mortar including PCC in bed and haunching against side and disposal outside MoD land complete all as specified and directed. |
| 139 | M&L for DWCPE (SN8) 180 (OD)/163(ID) mm diameter Pipes laid in trenches complete all specified and directed. |
| 140 | M&L for sand (Coarse sand) filling under floors, Top & bottom and sides of sewage pipes including watering and consolidation complete all as specified and directed. |
| 141 | Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles and disposal outside MoD land complete all as specified and directed. |
| 142 | M&L squared rubble walling, Jodhpur type, regular courses, well bonded, bedded and solidly hearted, built in cement mortar (1:6) complete all as specified and directed. |
| 143 | Extra over stone walling for hammer dressing to face stones with maximum depression on face from a straight edge not exceeding 20mm & dressing face beds and joints as specified to squared rubble walling Jodhpur type brought up to courses or regular course complete all as specified and directed. |
| 144 | M&L 15 mm thick , plaster in cement mortar (1:4) on stone masonry wall surfaces or surfaces other than fair faces of brick work or one side of lathing and finishing the surface even and smooth without using extra cement complete all as specified and directed. |
| 145 | M&L PCC 1:4:8 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed. |
| 146 | M&L PCC (1:2:4) using 40 mm graded crushed stone aggregate as in Cement concrete in Floors pavements, surface channels and drains complete all as specified and directed. |
| 147 | M&L PCC 1:2:4 (20 mm graded crushed stone aggregate) as in coping including necessary form work complete all as specified and directed. |
| 148 | Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stop ends etc complete all as specified and directed. |
| 149 | Returning filling in, including spreading, levelling, watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified and directed. |
| 150 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 151 | S&F 75 mm thick steel fibre reinforced (SFRC) man hole/ drain cover with iron frames (medium) complying to the standard specifications as mentioned in the IS 12592 BIS Standard, minimum load bearing capacity 5 ton/ sqm in square rectangular or circular shape complete all as specified and directed. |
| 152 | M&L for construction of RCC septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls, reinforcement steel, Base Slab, Baffle walls and Roof Slab including beams etc with Vent Shaft, manhole opening with cover connection etc. complete with effective depth of 1.5 meter and overall depth of 3 meter for 50 users, as per Drg No : AFB/TD/228/2018 Sheet 1R/1 complete all as specified and directed. |
| 153 | M&L for construction of soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed brick masonry with top ring of M-25 concrete, reinforcement steel, including intercepting chamber and screen chamber made of Brick masonry in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3.6 M dia X 3.0 M effective depth as per Drg No : TD/AR/65/07 complete all as specified and directed. |
| 154 | Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size complete all as specified and directed. |
| 155 | M&L for Stone Aggregate (Single size): 40 mm nominal size, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 156 | Providing and laying factory made chamfered edge Rubber moulded glossy finish Coloured Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 25 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as per direction of Engineer-in- Charge 60 mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern complete all as specified and directedNote : Sand shade be measured and paid separately |
| 157 | Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement: 3 coarse sand), including the cost of required centering, shuttering complete. 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size complete all as specified and directed. |
| 158 | M&L for Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand), Dark shade pigment using ordinary cement complete all as specified and directed. |
| 159 | Taking down carefully aluminium/copper point wiring (light/fan/ socket/ power) complete including fittings such as switch, socket, ceiling roses light fittings etc and making good disturbed surface of wall complete all as specified and directed. |
| 160 | Taking down old unserviceable copper/aluminium sub main wiring any size complete all as specified and directed. |
| 161 | Taking down old unsv Distribution boxes along with connected accessories MCB/MCCB/RCCB any type and size as required complete all as specified and directed. |
| 162 | M&L Point wiring with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with copper conductor drawn through and including non-metallic rigid PVC conduit and all conduit accessories concealed in wall/ceiling/fixed to roof/truss/column etc and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuity, fabricated branded modular metal flush box concealed in walls with suitable modular inner and outer plate for housing switches, socket outlet, and fan regulators etc, complete all as specified and directed for the followings:- (colour code to be followed) |
| 163 | One light point controlled by one, one way switch complete all as specified and directed. |
| 164 | One fan point controlled by one, one way switch complete all as specified and directed. |
| 165 | One call bell point controlled by one, one way switch complete all as specified and directed. |
| 166 | One socket outlet 6 Amps 5 Pin on independent board complete all as specified and directed. |
| 167 | One socket out let 6 Amps 5 pin on same board complete all as specified and directed. |
| 168 | One light point controlled by two switch two way complete all as specified and directed. |
| 169 | All as per item No 162.00 here in before but with cable size 4.0 Sq mm for one 6 pin 16 Amps socket out let on independent board for geyser with multistrand insulated copper earth continuity conductor of size 4.0 sqmm complete all as specified and directed.( circuit to be laid separately ) |
| 170 | M&L for modular switch 6 Amps single pole one way complete all as specified and directed. |
| 171 | M&L for modular switch 6 Amps single pole two way complete all as specified and directed. |
| 172 | M&L for modular bell push 6 Amps single pole one way complete all as specified and directed. |
| 173 | M&L for modular socket outlet 2/3 pin 6 Amps combined 2 module complete all as specified and directed. |
| 174 | M&L for modular switch 16 Amps single pole one way, one module complete all as specified and directed. |
| 175 | M&L for modular Socket 16 Amps single pole one way, one module complete all as specified and directed. |
| 176 | S&F ceiling rose , 3 pin/pvc/polycarbonate, isolated body complete all as specified and directed. |
| 177 | S&F modular blanking plate complete all as specified and directed. |
| 178 | S&F call bell/buzzer suitable for single phase ,230V, complete all as specified and directed. |
| 179 | S&F modular electronic fan regulator 2 module complete all as specified and directed. |
| 180 | S&F single pole and neutral enclosure new pattern with a two pin and earth plug and socket AC Box complete with one single MCB SP 20 Amps complete all as specified and directed. |
| 181 | S&F triple pole and earth enclosure with a three pin and earth plug with socket complete with one triple pole MCB 32 Amps complete all as specified and directed. |
| 182 | S&F triple pole and earth enclosure with a three pin and earth plug with socket complete with one triple pole MCB 63 Amps complete all as specified and directed. |
| 183 | S&F vertical type TPN 4 way, double door, sheet steel , suitable for MCCBs as I/C distribution board, 415 V, on surface/ recess IP-43 protection isolated neutral bar, insulated busbar assembly, door earthing complete with interconnections, powder painted including door earthing etc. as required (but without MCB/MCCB/RCCB/Isolator) complete all as specified and directed. |
| 184 | S&F Horizontal type TPN 4 way, double door, sheet steel , suitable for MCCBs as I/C distribution board, 415 V, on surface/ recess IP-43 protection isolated neutral bar, insulated busbar assembly, door earthing complete with interconnections, powder painted including door earthing etc. as required (but without MCB/MCCB/RCCB/Isolator) complete all as specified and directed. |
| 185 | S&F MCCB fixed TM range 415 volts, 100 Amps, 16 KA, 4 pole complete all as specified and directed. |
| 186 | S&F MCCB fixed TM range 415 volts, 125 Amps, 16 KA, 4 pole complete all as specified and directed. |
| 187 | S&F MCCB fixed TM range 415 volts, 200 Amps, 36 KA, 4 pole complete all as specified and directed. |
| 188 | Supply, fixing and connecting up complete DB TPN 4 way suitable for upto 63-100 Amp MCB TPN as incomer, double door 415 V AC, 50 Hz, with a provn to mount MCB as outgoing 10 Amp to 40 Amp with highly reliable and tested as per IEC 61439-2, degree of protection IP-54, concealed in wall , isolated neutral bus bar and easy to install complete all as specified and directed. |
| 189 | Supply, fixing and connecting up complete DB TPN 8 way suitable for upto 63-100 Amp MCB TPN as incomer, double door 415 V AC, 50 Hz, with a provn to mount MCB as outgoing 10 Amp to 40 Amp with highly reliable and tested as per IEC 61439-2, degree of protection IP-54, concealed in wall , isolated neutral bus bar and easy to install complete all as specified and directed. |
| 190 | S&F MCB 4 Pole, 415 volts, fixed type 100 Amps with breaking capacity 16 KA , thermal class ‘C’ confirming to IEC-60947-II with adjustable overload settings, adjustable short circuit settings suitable for TPN DB including connecting up complete all as specified and directed. |
| 191 | S&F 40-63 Amps rating, Single Pole, 240 volts, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. complete all as specified and directed. |
| 192 | S&F 8 way, single pole and neutral ,sheet steel, MCB distribution board 240 V, on surface /recess, complete with tinned copper bus bar ,neutral bus bar ,earth bar, din bar ,interconnection, powder painted including earthing etc.as required complete all as specified and directed. |
| 193 | S&F 12 way, single pole and neutral ,sheet steel, MCB distribution board 240 V, on surface /recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnection, powder painted including earthing etc as required complete all as specified and directed. |
| 194 | S&F 6 Amps to 32 Amps rating, Single Pole, 240 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. ( 10 kA breaking Capacity ) complete all as specified and directed. |
| 195 | S&F 40-63 Amps rating, Single Pole & Neutral, 240 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. ( 10 kA breaking Capacity) complete all as specified and directed. |
| 196 | S&F LED slim edge 36 watt 6500 K panel light in 2x2,(<100 lumen/watt) full lit luminaire with glare free uniform illumination with longer life and less maintenance with all accessories complete all as specified and directed. |
| 197 | S&F wall mounted LED batten with polycarbonate housing and integrated electronic driver tube light fitting 25 W 4 ft long 220 V AC with high lumen output, environmental friendly, energy efficient and connecting to ceiling Rose with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 198 | S&F wall mounted LED batten with polycarbonate housing and integrated electronic driver tube light fitting 36 W 4 ft long 220 V AC with high lumen output, environmental friendly, energy efficient and connecting to ceiling Rose with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 199 | S&F wall mounted LED batten with aluminium housing & integrated electronic driver,2 Feet,10 watt 220 V AC including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 200 | S&F Lamp holder, 220 V AC, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed. |
| 201 | S&F 30 W High efficient LED Street light / Building security light fitting with pressure die cast LM6 Aluminium housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminaire is 100lm/W with a life class of 50,000 burning hours at L70. The colour temperature is around 6500 K with a colour rendering index of 70. The luminaire is IP:66 protected with IK05 impact resistance. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including provision of 40mm dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole fixed complete all as specified and directed. |
| 202 | S&F LED PLUS 15 W ,B22 CDL bulb of 15 watt, 6500K complete all as specified and directed. |
| 203 | M&L for concealed sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 2X6 Sqmm and one run of 6 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, ISI marked concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc. complete all as specified and directed.Note : Two runs of cable with one run of earth wire and PVC conduit shall be measured & paid for as one length. |
| 204 | M&L for concealed sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 2X10 Sqmm and one run of 10 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of suitable size mm dia with wall thickness not less than 1.8 mm, ISI marked concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc. complete all as specified and directed.Note: Two runs of cable with one run of earth wire and PVC conduit shall be measured & paid for as one length. |
| 205 | M&L for concealed sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 2X16 Sqmm and one run of 16 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of suitable size mm dia with wall thickness not less than 1.8 mm, ISI marked concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc. complete all as specified and directed.Note: Two runs of cable with one run of earth wire and PVC conduit shall be measured & paid for as one length. |
| 206 | M&L for concealed sub main wiring with four runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 4x10 Sqmm and one run of 10 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of suitable size mm dia with wall thickness not less than 1.8 mm, ISI marked concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc. complete all as specified and directed.Note: four runs of cable with one run of earth wire and PVC conduit shall be measured & paid for as one length. |
| 207 | M&L for concealed sub main wiring with four runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 4x16 Sqmm and one run of 16 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of suitable size mm dia with wall thickness not less than 1.8 mm, ISI marked concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc. complete all as specified and directed.Note: four runs of cable with one run of earth wire and PVC conduit shall be measured & paid for as one length. |
| 208 | M&L for Rigid non-metallic PVC conduit 25 mm dia concealed in walls for Telephone/LAN/WAN exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified and directed. |
| 209 | M&L for Rigid non-metallic PVC conduit 20 mm dia concealed in walls for Telephone/LAN/WAN exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified and directed. |
| 210 | S&F Junction Boxes (1 to 4 way) suitable for Telephone/LAN/WAN socket complete all as specified and directed. |
| 211 | S&F Telephone/LAN/WAN socket outlet modular type complete all as specified and directed. Please Enable Macros to View BoQ information |
| 212 | S&F Telephone/LAN/WAN socket outlet modular type complete all as specified and directed. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail