| 1 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 2 | Point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in existing PVC conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising of One light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. Note : (i) Unit rate is inclusive of making good the disturbed surfaces by provding by wall putty/POP after mason work and finshing to match the original surface and nothing extra shall be paid on this account. (ii)Unit rate is inclusive of cutting chases in wall /foor/PCC for sunken box and making good the disturbed surfaces to match the original and nothing extra shall be paid on this account. |
| 3 | All as per serial item 02 herein before but for socket outlet 3 pin 5 Amps on same board complete all as specified and directed |
| 4 | All as per serial item 02 herein before but for socket outlet 3 pin 6 Amps on independent board complete all as specified and directed |
| 5 | All as per serial item 02 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSH cable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor |
| 6 | Material and labour for point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising of One light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. Note : Unit rate is inclusive of making good the disturbed surfaces by provding by wall putty/POP after mason work and finshing to match the original and nothing extra shall be paid on this account. Note :Unit rate is inclusive of cutting chases in wall /foor/PCC and making good the disturbed surfaces to match the original and nothing extra shall be paid on this account. |
| 7 | All as per serial item 6 herein before but for socket outlet 3 pin 6Amps on same board complete all as specified and directed |
| 8 | All as per serial item 6 herein before but for socket outlet 3 pin 6 Amps on independent board complete all as specified and directed |
| 9 | All as per serial item 6 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSH cable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor |
| 10 | Point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including new steel sunken boxes 1.2mm thickness covered with provision of 3mm thick plastic laminated sheet, comprising of One light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. Note :Unit rate is inclusive of cutting chases in wall /foor/PCC and making good the disturbed surfaces to match the original finishes surface and nothing extra shall be paid on this account. |
| 11 | All as per serial item 10 herein before but for socket outlet 3 pin 6Amps on same board complete all as specified and directed |
| 12 | All as per serial item 10 herein before but for socket outlet 3 pin 6 Amps on independent board complete all as specified and directed |
| 13 | All as per serial item 10 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSH cable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor |
| 14 | Point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in existing conduit terminated on and including new steel sunken boxes 1.2mm thickness covered with provision of 3mm thick plastic laminated sheet, comprising of One light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. Note : Unit rate is inclusive of making good the disturbed surfaces to match the original and nothing extra shall be paid on this account. Note :Unit rate is inclusive of cutting chases in wall /foor/PCC and making good the disturbed surfaces to match the original and nothing extra shall be paid on this account. |
| 15 | All as per serial item 14 herein before but for socket outlet 3 pin 6 Amps on same board complete all as specified and directed |
| 16 | All as per serial item 14 herein before but for socket outlet 3 pin 6 Amps on independent board complete all as specified and directed |
| 17 | All as per serial item 14 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSH cable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor |
| 18 | Switch modular type (ISI marked), single pole, one way 6 Amps, one module (ISI marked), complete all as specified & directed. |
| 19 | Switch modular type (ISI marked), single pole, one way 16 Amps, one module (ISI marked), complete all as specified & directed. |
| 20 | Socket shutters outlet 2/3 pin 6 Amp modular type multi purpose two module (ISI marked), complete all as specified & directed. |
| 21 | Socket shutters outlet 2 in 1 pin 6/16 Amp modular type multi purpose combined 2 module (ISI marked), complete all as specified & directed. |
| 22 | Modular switch type stepped fan regulator, single pole, 230 volt two module complete all as specified and directed. |
| 23 | Modular switch type bell push, single pole, 230 volt one module,(ISI marked) complete all as specified and directed. |
| 24 | Switch piano, flush type, 6 amps, 230 volts, single pole, one way (ISI marked) complete all as directed by Engineer-in-charge |
| 25 | Switch piano, flush type, 16 Amps, 230 volts, single pole, one way (ISI marked) complete all as directed by Engineer-in-charge |
| 26 | Sockets outlet multipurpose 2 in 1 pin, 6 and 6 Amps flush type ISI marked all as specified and directed by Engineer-in-charge |
| 27 | Sockets outlet multipurpose 2 in 1 pin, 6 and 16 Amps flush type ISI marked all as specified and directed by Engineer-in-charge |
| 28 | Stepped type electronic fan regulator flush type complete all as specfied and directed. |
| 29 | Bell push, paino type, 6 amps, 230 volts, single pole, complete all as directed by Engineer-in-charge |
| 30 | Electric Bell, AC, 230 volts, single pole all as specified and directed by Engineer-in-charge. |
| 31 | Ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals (ISI marked) all as specified and directed by Engineer-in-charge. |
| 32 | Lamp holder, PVC/Polycarbonate type with back plate modular type fixed on wall suitable for batten fitting ,complete all as specified and directed. |
| 33 | LED lamp 9 watts, B-22 type complete all as specified . |
| 34 | LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, fixed as in repair complete all as specified and directed. |
| 35 | LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete fixed as in repair complete all as specified and directed. |
| 36 | LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size fixed as in repair complete all as specified and directed. |
| 37 | Taking down carefully old copper or aluminium sub main wiring of any Nos of wiring and size with earth wire on wooden batten/ surface conduit/ casing- capping complete with its all accessories and making good disturbed surfaces of wall , floors etc complete all as specified and directed. |
| 38 | Sub main wiring with two single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 4 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 4 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC concealed conduit 25mm size(minimum size), complete all as specified and directed. |
| 39 | Sub main wiring with two single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 6 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 6 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC concealed conduit 25mm size(minimum size), complete all as specified and directed. |
| 40 | Sub main wiring with two single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 10 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 10 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC concealed conduit 25mm size(minimum size), complete all as specified and directed. NOTE FOR SERIAL ITEM NO 38, 39 & 40: (i) Two runs of cable, one run of earth wire shall be considered as one running metre(ii) colour code shall be Red for phase, Black for neutral and green for earth |
| 41 | Supply and fixing sub main wiring with Four single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 10 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 10 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC concealed conduit 25mm size(minimum size), complete all as specified and directed. Note : (i) Four runs of cable, one run of earth wire shall be considered as one running metre(ii) colour code shall be Red for phase, Black for neutral and green for earth |
| 42 | Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10cm girth Complete all as specified and directed . |
| 43 | Disconnecting the power supply and taking down carefully by unscrewing from boards fittings and fixtures such as DBs, Junction Box, Panels of any size complete with all MCCB's ,MCB's etc and removing from site, Complete all as specified and directed . |
| 44 | MCCB, 100 Amps, four pole, 3 phase , 16KA, 415 volt with adjustable thermal and maganetic release, with proper thimble complete all as specified and directed |
| 45 | Vertical TPN distribution board double door flush mounting with provisions for MCCBs incomer upto 125 Amps & outgoing 4 way having IP 43 protection Complete all as specified and directed . |
| 46 | MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 12 way SPN with 200 Amps busbar 240V completed all as specified and directed. |
| 47 | MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 08 way SPN with 200 Amps busbar 240V completed all as specified and directed. |
| 48 | MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 04 way SPN with 200 Amps busbar 240V completed all as specified and directed. |
| 49 | Sheet metal enclosure for DB, flush mounted single door suitable for 2 way SPN without busbar 240V completed all as specified and directed. |
| 50 | MCB, SPN , 240 volt, 32Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 51 | MCB, SP , 240 volt, 40 to 63Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 52 | MCB ,SP , 240 volt, 6Amps to 32Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 53 | Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead ) by means of galvanized bolts, nuts and washers all as shown in electrical plate no 5 of MES Schedule Part-I (1991) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick pre-cast RCC cover in 1 : 2 : 4 type B1 with 3 Nos 8 mm dia TMT bars both ways complete all as specified & directed. |
| 54 | Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron strip 32 x6mm, (main earthing lead ) by means of galvanized bolts, nuts and washers all as shown in electrical plate no 5 of MES Schedule Part-I (1991) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick pre-cast RCC cover in 1 : 2 : 4 type B1 with 3 Nos 8 mm dia TMT bars both ways complete all as specified & directed. |
| 55 | Maintenance free chemical earthing using 40mm dia 3.00 mtr long GI earthing electrode capsule complete, having following specification :- (a) Making a hole of 150mm dia to a depth of 3.50 mtr from GL and placing the earthing electrode inside the hole.(b) Filling the back fill with enhancing compound of superior quality, electrogrip back fill compound qty approx 50 Kgs properly mixed, around the earthing electrode. (c) Continous compaction of backfill compound to form a uniform mixture all around the earthing electrode.(d) Construction of brick masonry earth pit of internal size 30cm x 30cm and 30cm deep including finishing work and fixing of CI cover as per the size of the pit complete all as specified and directed(e) Testing for proper working.NOTE- Earth resistance at each grid should be less than 2 ohm at test point . |
| 56 | LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver,including lamp bracket upto 1.5metre length as per suitable for fitting including clamp with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, including taking down old street lght complete all as specified and directed. |
| 57 | LED panel recess mounted ultra slim 2'x2' - 36 watts ultra slim (cool day, 6000K) ceiling light, aluminum extruded housing with milky diffuser, heat exchanger unit, LED driver, surge protection complete suitable for perfect lighting cutting hole of required size in POP/false ceiling making good disturbed including taking down any type ceiling fitting complee all as specified and directed. |
| 58 | LED panel recess mounted ultra slim 2'x2' - 36 watts ultra slim (warm white light, 4000 K) ceiling light, aluminum extruded housing with milky diffuser, heat exchanger unit, LED driver, surge protection complete suitable for perfect lighting cutting hole of required size in POP/false ceiling making good disturbed including taking down any type ceiling fitting complee all as specified and directed. |
| 59 | Supply lying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor , served with inner sheating of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, 10 Sq mm , one twin core cable flat or circualr, including taking out old service cable complete all as specified and directed. |
| 60 | Exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm and provision of flexible copper cable 3 core from ceiling rose to exhaust fan , fixed as in repair complete all as specified and directed. |
| 61 | Ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) and provision of flexible copper cable 3 core from ceiling rose to fan fixed as in repair complete all as specified and directed. |
| 62 | Multipurpose PVC box with 05 Amps multipin socket and 05 Amps switch with necessary connection including taking down oldunserviceable/rusted box complete and making good the surface as per existing, fixed as in repair complete all as specified and directed |
| 63 | Multipurpose PVC box with 15 Amps multipin socket and 15 Amps switch with necessary connection including taking down oldunserviceable/rusted box complete and making good the surface as per existing, fixed as in repair complete all as specified and directed |
| 64 | Casing capping with fixing accessories of size 15mm width fixed as in repair complete all as specified and directed . |
| 65 | Casing capping with fixing accessories of size 20mm width fixed as in repair complete all as specified and directed . |
| 66 | Industrial light CORVUS-E 75 watt powder coated PDCaluminium LED highway integral industrial SMD LED with pressure die-cast aluminium housing with integrated lens polycarbonate cover, complete with all accessories inlduing wiring connection upto 20 metre height , fixed as in repair complete all as specified and directed. |
| 67 | aesthetically designed recessed mounted panel in a light weight plastic body 10 W LED 4000K fixed as in repair complete all as specified and directed. |
| 68 | aesthetically designed recessed mounted panel in a light weight plastic body 10 W LED 6000K fixed as in repair complete all as specified and directed. Please Enable Macros to View BoQ information |