| 1 | Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 2 | Material and labour for 40mm thick plain cement concrete 1:2:4 type B0 using 12.5 mm graded stone aggregate as in as in leveling course including use of form work as necessary complete all as specified and as directed. |
| 3 | Material and labour for 100mm thick plain cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base of floors including necessary form work all as specified and as directed. |
| 4 | Material and Labour for 75mm thick Plain Cement Concrete 1:3:6 type C2 using 40 mm graded stone aggregate as in plinth protection, floors, pavings and hardstanding etc, finished even smooth without using extra cement etc including necessary forwork, complete all as specified and as directed. |
| 5 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) exc 1.5 sqm but not exc 4 sqm each complete all as specified and as directed. |
| 6 | Supply and fix Rolled mild steel Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe 410-W quality A (Gde-E-250) complete all as specified and directed. |
| 7 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed. |
| 8 | S&F prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength 550 MPA as in roof covering in roof covering /cladding to wall, fixed with self tapping screws including providing of rubber washer/Bitumen washer with filling of Bitumen between joint of sheet and Self tapping screws complete all as specified. |
| 9 | S&F prepainted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength 550 MPA as in roof covering in roof covering /cladding to wall, fixed with self tapping screws including providing of rubber washer/Bitumen washer with filling of Bitumen between joint of sheet and Self tapping screws complete all as specified. |
| 10 | M&L for MS work as in Wind Tie in roof and MS structural works in trusses, etc with screwed ends including nuts, washers and mild steel plates for walls chimneys, roofs arches etc any kind rods and straining bolts conforming to Fe 410-0 or Fe 310-0 complete all as specified . |
| 11 | M&L for preparation of new or previously untreated steel surfaces of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide primer complete all as specified and as directed |
| 12 | Material and labour for preparation of old decorated steel & iron surfaces of any description exceeding 10 cm width or grith not otherwise specified and applying one coat of syntheic enamel paint applied to surfaces, all as specified and as directed. |
| 13 | Taking down cement plastering on concrete or Brick works surface racking out joints, hacking for key , scrubbing down with water, removing rubbish/debris etc complete all as specified and as directed. |
| 14 | Material and labour for rendering 10mm thick in Cement Mortar 1:6 on fair faces of brick walls or on concrete surfaces, finished even and smooth,without using extra cement complete all as specified and directed. |
| 15 | Material and labour for 15 mm thick rendering on brick/concrete surfaces in two layers in CM 1:4, finishing coat of 5mm thick, finished even and smooth without using extra cement complete all as specified and as directed. |
| 16 | Material and labour for preparation of of new plastered/concrete surfaces of walls and applying two coats of acrylic distemper of approved shade/tint over a coat of primer, over surface of wall all as specified and as directed. |
| 17 | Material and labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 18 | M&L for complete removal by Washing, rubbing down and stopping and preperation of distempered and painted surfaces of walls, pillars,cornices by brooming down etc including filling depressions of scrapped surfaces with wall care putty (1 mm thick) and preparation of surfaces for further treatment and applying two coats of distemper oil emulsion over a coat of primer complete all as specified & directed. |
| 19 | Material and labour for complete removal by Washing, rubbing down and stopping, preparing old external plaster surface of walls and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 20 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc. to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc. |
| 21 | M&L point wiring complete with 1.5 Sqm sincle core PVC insulated unsheathed FRLS cable 1100 volts grade (ISI marked) with multi stranded copper conductor drawn through and including non-metallic rigid PVC medium grade conduit and conduit accessories (ISI) marked concealed in wall/fixed to roof, ceiling etc and incl provn of 1.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FRLS (ISI marked) as earth continuity conductor, fabricated sunken terminal box made out of 1.60 mm thick sheet steel duly painted concealed in walls, with 3mm thick bakelite/PVC sheet ISI marked top cover with brass/chromium plated screws and cup washers for housing switches, socket outlets, fan regulators etc, all as specified and as directed for the following :- (a)One light point or one light/ exhaust fan/ fan point controlled by one switch with cables 1.5 sqmm size |
| 22 | Comprehensive preventive maintenance by technically qualified technician and rendering operationally EOT crane including assemblies inspection to maintenance of longitude travel/cross travel system assy and checking lubricating of gear system topping up of lubricant upto desired level replacement of gasket, nut, bolts, washer, split pins for proper tightness and safety including replacement of worn out parts, checking of coupling unit travel track etc. All other miscellaneous item & ensure safe operation of crane including replacement of worn out parts. Preventive maintenance of housing system assy comprising of inspection checking including topping up/charging of lubricants & gasket inspection and checking of bracing, pully, nuts, dollys washer, split pins, bushes, hooks, checking of housing pully and lubrication thereof inspection of hoisting rope for cut abberation etc & cleaning up all greasy/clipping materias inspection servicing, setting and testing breaking limit system for its safe operation. Inspection, checking, setting out including replacement of damaged wiring of electric system in and outside cabins. Repair/replacement of all other miscellaneous items for necessory safe and satisfactory functioning of crane including replacement of worn out spares and preventive maintenance of electrical control system comprising of following:- Inspection checking decarbonising & tightning of electrical connection in total system including replacement of thimbles etc. Inspection & checking of fuses, setting & tightning the same as per their capacity and inspection and setting of voltage system including replacement of fused indicating lamp etc. Repair /replacement of all othe miscelleneous item like main switches, MCBs, hand operating pendent etc & replaceement of all other spares complete for safe & satisfatcory run of crane complete for effective operation of EOT cranes and as directed by the Engineer-in-charge. |
| 23 | Taking down exhaust fan of 450mm sweep, dimantling blades and removing fan and balde and transporting to local market, cutting unserviceable winding from fan state & rewinding same with super enamelled copper winding wire of existing gauge size including throughly cleaning all the components, oiling greasing & replacement of rusted unserviceable screws, hanging clamps with rubber reel, canopy condensers, bush, bearing & flexible copper connection wire etc and re-assumbling, fixing and testing for satisfactory operation, complete all as directed. Please Enable Macros to View BoQ information |
| 24 | Taking down exhaust fan of 450mm sweep, dimantling blades and removing fan and balde and transporting to local market, cutting unserviceable winding from fan state & rewinding same with super enamelled copper winding wire of existing gauge size including throughly cleaning all the components, oiling greasing & replacement of rusted unserviceable screws, hanging clamps with rubber reel, canopy condensers, bush, bearing & flexible copper connection wire etc and re-assumbling, fixing and testing for satisfactory operation, complete all as directed. Please Enable Macros to View BoQ information |