| 1 | Dismantling of Asbestos cement (corrugated,semicorrugated, etc.) sheets in roof coverings coomplete all as specified and as directed by Engr-in-Charge. |
| 2 | S&F Pre painted galvanised aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screw complete all as specified and directed. |
| 3 | S&F Pre painted galvanised aluminium zinc coating GI based Plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screw complete all as specified and directed. |
| 4 | Dismantling timber scantling 40 Sqcm and over in section, in any position of framed work complete all as specified and as directed. |
| 5 | Material and labour for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 ®including cutting and welding as required complete all as specified and directed. |
| 6 | M&L for preparation of new surfaces of steel and applying two coat synthetic enamel paint over a coat of red oxide complete all as specified and as directed by Engr-in-Charge. |
| 7 | Excavating in post holes in soft/ loose soil (or similar holes) each n exc. 0.5 cum , getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete. |
| 8 | Material and labour for plain cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in foundation, filling, mass concrete works complete all as specified and as directed by Engr-in-Charge. |
| 9 | M & L water proofing treatment to RCC roof slab, walls, chhajjas ets, shall be carried out as specified below and as directed by Engineer-in-Charge including taking down old waterproofing tratement. (a) M&L for 10mm hick plaster screed bed layer in CM 1:3 on concrete surfaces. (b) Preparing plastered surfaces of roof slab, walls, chhajjas etc, by brooming with broom sweeping free from dirt dust etc & evenly applying a coatt of approved bitumnous primer @ 0.20kg/Sqm of area complete all as specified. (c) Laying App polymer modified approved membrane, non woven, polyester, weighing not less than 3.5 kg/Sqm and 3mm thick with laps & overlaps as specified & joints sealed and applied complete by torch application method all as specified & directed by Engr-in-Charge. Carrying out test by flooding water for 24 hrs for leakagge & seepages and rectifying the same to the entire satisfaction of GE. (d) Finally applying a coat of solar reflective bituminous aluminium paint @ 0.15 ltr/Sqm on the top of membrane surfaces complete all as specifed & as directed by Engr in Charge. |
| 10 | Taking down frames (wiithout taking offf shutters from the frame) area exc 1.5 sq. m but n exc 4 sq. m each complete all as specified and directed. |
| 11 | Taking down frames (wiithout taking offf shutters from the frame) area n.exc 1.50 sqm complete all as specified and directed.. |
| 12 | Taking down shutters for any description exc 1 sqm but n.exc 2 sqm complete all as specified and directed. |
| 13 | Taking down shutters for any description n.exc 1 sqm complete all as specified and directed. |
| 14 | S&F 125mmX60mm Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and as directed. |
| 15 | S&F 105mmX60mm Pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and as directed. |
| 16 | M&L for plain cement concrete type B-0 (1:2:4) 12.50mm graded aggregate in as in filling of press steel Chowkats complete all as specified and as directed. |
| 17 | M&L 2nd Class Hard wood ( Sal) Plain , solid , straight chowkhats and frames , wrought , framed rebated on the solid , rounded or chamfered , put together with glue, pinned at joints, supplied and fixed including tarring back of chowkhats with tar or coal tar black paint complete all as specified and directed. |
| 18 | M&L for 30 mm thick glazed and skeleton shutters for door shutters of 1st class soft wood open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR PartI, Section 8, clause 8.24 (a); supplied and fitted to chowkats kiln seasoned and chemically pressure treated all as specified and directed. |
| 19 | M&L for 30 mm thick glazed and skeleton shutters for window shutters of 1st class soft wood open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR PartI, Section 8, clause 8.24 (a); supplied and fitted to chowkats kiln seasoned and chemically pressure treated all as specified and directed. |
| 20 | Supply and fixing Flush shutters in doors, 30 mm thick solid core construction, with particle board core and plywood face panels, commercial type on both sides complete all as specified and directed. |
| 21 | S&F 125 mm Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed by Engr-in-Charge. |
| 22 | S&F 100 mm Extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed by Engr-in-Charge. |
| 23 | Supply and fixing Aluminium, anodised, barrel tower bolts of extruded section and fixed, 200 mm length of bolt complete all as specified.on and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed by Engr-in-Charge. |
| 24 | Supply and fixing Aluminium, anodised, barrel tower bolts of extruded section and fixed, 150 mm length of bolt complete all as specified.on and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed by Engr-in-Charge. |
| 25 | S&F for Mild steel butt hinges of size 100mm medium weight cold rolled complete all as specified and directed. |
| 26 | S&F for Mild steel butt hinges of size 75 mm medium weight cold rolled complete all as specified and directed. |
| 27 | M&L for preparation of untreated new wooden surface of any description over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint, with a coat of pink primer. |
| 28 | S&F of 3 mm thick plain glass, ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane, complete all as specified and directed. |
| 29 | S&F Stainless steel wire cloth 0.56 mm nominal dia of wire and average width of aperature 1.18 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed. |
| 30 | S&F solid PVC door frame of size 50mm x 47mm made out of 5 mm plain colour PVC sheet reinforced with MS Square tube in opening, complete all as specified and as directed. |
| 31 | S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck in side with solvent cement for styles and plain colour PVC sheet for top rail, lock rail & bottom rail on either sides and as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the styles & rails with suitable PVC sheet beading, and joint together with solvent cement, complete all as specified and as directed. |
| 32 | S&F in repair 20mm dia curtain rails, mild steel, chromium plated with fixing bracket stops, rollers etc, complete all as specified and as directed. |
| 33 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets any thickness including cover fillets, complete all as specified and as directed. |
| 34 | M&L Solid PVC Wall Lining consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement /fillet and fixing at site on PVC frame as per specifications and drawing complete all as specified and as directed by Engr-in-Charge. |
| 35 | S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing,complete all as specified and as directed. |
| 36 | S&F IInd class hard wood in scantlings clean sawn timber fixed as in door frame, frame work in ceiling and similar work complete all as specified and as directed. |
| 37 | M&L for preparing surfaces of wood and wood based material, new or old of any description and girth and treated with creosote oil complete all as specified and as directed. |
| 38 | S & F for suspended false ceiling using anodised GI exposed ceiling suspension system of grid size 60 cm x 60 cm width main runner 'T' size 24 mm x 24 mm x 0.3 mm thickness and coress Tee of size 24 mm x 24 mm x 0.43 mm thick (using 60 cm x 60 cm E board classic 4 mm thick ceiling board) to be placed in grid of GI sytem duly suspended with 4 mm dia GI bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing position for light fixtures, air conditioning dufuser and ducks, sprinkler, smoke detector etc. The main runner to be secured to structural soffit by hanger @ 1220 mm maximum C/C. The last hanger at the end of each runner should not be placed at more than 450 mm from the adjacent wall. Flush fitting 1200 mm cross 'T' to be inter locked between amin runner @ 610 mm C/C so as to form 600 mm x 600 mm grid complete all as specified and directed. |
| 39 | S&F 4mm thick asbestos cement plain building board, fixed in ceiling flat or sloping to timber frame work with screws complete all as specified and as directed. |
| 40 | S&F wooden cover fillets square or rectangular and sectional area exc 3 & n.exc 6 Sqcm of second class hard wood secured with nails complete all as specified and as directed. |
| 41 | S&F IInd class hard wood exc 13 & not exc 25 sqcm plain, fillets, square, rectangular or triangular in section, clean swan, secured with nails or brads complete all as specified and as directed. |
| 42 | Preparation of new wooden surfaces of any description n exc 10cm width or girth when unconnected with other painting or when painted in different tint and one coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 43 | Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing), in floors, aprons etc .laid dry or laid dry and pointed including removing of demolished material from work site at any distance outside MD land complete all as specified and directed.complete all as specified. |
| 44 | M&L for vitrified ceramic tiles 10 mm thick (square/rectangular) Dark Shade polished area of each tiles not exceeding 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in cm 1:6 all as specified and directed. |
| 45 | All as per above item No- 44 (here in before) but on dado / skirting over and including 10mm thick rendering in CM 1:4, complete all as specified and as directed. |
| 46 | Dismantling of stone slab of any description including cement mortar bedding but not backing, complete all as specified and as directed. |
| 47 | M&L for 18 to 20 mm thick granite of any type/colour as approved, work (table rubbed mirror polished) edges rounded chamfered and bull nosed laid and fixed in any position (Vertical/Horizontal/Inclined) over and including cement screed over Cement mortar bedding in CM(1:4) 10 thick and pointed in white or colour cement with admixer of pigment to match with shade of granite stone incl grinding and polishing complete all as specified and as directed by Engr-in-Charge. |
| 48 | Demolition of cement concrete ( unreinforced ) in ground floors and pavings not exceeding 15 cm thick above or below ground level, including removing of demolished material from work site at any distance outside MD land complete all as specified and directed. |
| 49 | M&L cement concrete type B-0 (1:2:4) usin 12.5mm graded agg as in flooring 40mm thick as in sub base floor complete all as specified and directed |
| 50 | Material and labour for plain cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in foundation , filling, mass concrete works complete all as specified and directed. |
| 51 | Demolition of Cement concrete ( reinforced) of any description and in any position not otherwise specifically provided for including reinforced cut to facilitate demolition complete including removing demolished material from work site all as specified and directed. |
| 52 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and as directed by Engr-in-Charge. |
| 53 | M&L for slabs supported on walls, beams and columns in floors, roofs, kitchen slabs, balconies, canopies made in RCC 1:2:4 type B1 using 20mm graded aggr all as specified and as directed. |
| 54 | Material and labour for Mild steel deformed or twisted bars ( TMT) 8 mm dia and over, cut to length, bent to shape required, hooking ends and binding with including mild steel wire(annealed) not less than 0.90 mm dia. or higher complete all as specified and as directed. |
| 55 | S&F sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and as directed. |
| 56 | S&F of 20 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings complete on walls all as specified including taking down old GI tubing complete all as specified and as directed by Engr-in-Charge. |
| 57 | Cutting chases for concealed water tubing and making good in CM 1:3 on brick wall cutting n.exc 10 Cm in girth complete all as specified and as directed by Engr-in-Charge. |
| 58 | S&F in repairs vitreous china wash down water closet pan (pedestal pattern) coloured (including two Nos fixing bolts incl PVC seat cover but excluding flushing cistern and flush pipe) complete including making good to floor with and including fixing of P or S trap, complete all as specified and as directed. |
| 59 | Supply and fixed in repair of PVC low level flushing cistern 10 Ltr capacity ISI mark syphonic action type push button incl flush pipe, ball valve ,handle incl bracket complete as approved make commander complete all as specified and as directed by Engr-in-Charge. |
| 60 | S&F PVC connection 15 mm size with PTMT nut of length 450 mm complete all as specified and as directed by Engr-in-Charge. |
| 61 | S&F in repair15 mm dia angular stop cock with wall flange , screwed both ends for iron pipe or for union complete all as specified and as directed by Engr-in-Charge. |
| 62 | S&F in repair 15mm bib Cock CP fency type screwed down for iron pipe 15 mm bore complete all as specified and as directed by Engr-in-Charge. |
| 63 | S&F in repairs vitreous china wash hand basin, (white), flat back of size 550x400 mm with and including two CI brackets, brass chromium plated waste coupling fittings and PVC waste pipe complete all as specified and as directed. |
| 64 | S & F in repairs 15 mm dia bore fancy type pillar taps ,cast copper alloy chromium plated screwed down high pressure with or without lettered 'Hot' or 'Cold' with capstan head, screwed for iron pipes or for union and fixed, complete all as specified and as directed. |
| 65 | S&F in repairs 15 mm dia bore cast copper alloy chromium plated fancy type wall mixer with pronision for overhead shower with and 115mm long bend pipe for cold & hot water complete all as specified and as directed. |
| 66 | S&F in repair overhead Shower dia 180 mm Round Shape single flow with and shower arm dia 20 mm & 450mm long round shape with 90 degree for wall mounted shower with flange complete all as specified and as directed. |
| 67 | S&F in repair chromium plated hand shower (health fauset), telephonic type with 8mm dia, 1 meter long CP flexible tube with wall hook and jet of approved make, suitable for 15 mm bore iron pipes or for unions and fixed complete all as specified and directed. |
| 68 | S&F in repair soap dish, brass, chromium plated fixed to wall with brass chromium plated screw, complete all as specified and as directed. |
| 69 | S&F in repair CP towel rail 20 mm dia D type, 60 cm long fixed with CP screws and rowel plug in wall, complete all as specified and as directed. |
| 70 | S&F in repair sheet glass shelf / corner shelf consisting of 5.5mm thick sheet glass self assembly 12cm width with chromium plated guard and railing 60cm long, complete all as specified and as directed. |
| 71 | S & F in repairs 15 mm dia bore cast copper alloy chromium plated angle cock/stop cock with long shank and cup (concealed type) screwed down high pressure with capstan head, screwed both ends for iron pipes or for union and fixed, complete all as specified and as directed. |
| 72 | S&F in repair toilet paper holder chromium plated fixed to wall with chromium plated brass screw, complete all as specified and as directed. |
| 73 | Demolition of brick work or stone / boulder masonary, built in cement mortar including all quoins, arches pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and as directed by Engr-in-Charge. |
| 74 | M&L for brick work with sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified and as directed. |
| 75 | M&L for brick work with sub class 'B' bricks, straight or curved on plan exc 6 m mean radius in half brick thick wall built in CM 1:4 complete all as specified and as directed. |
| 76 | Taking down cement plaster including raking out joints hacking for key, scrubbing down with water , complete all as specified and as directed. |
| 77 | M&L for rendering 15mm thick plaster in CM (1:6) on brick or concrete surfaces finished even & smooth, complete all as specified and as directed. |
| 78 | M&L for two coats of oil bound distemper over a coat of primer on newly plastered surface of wall over a coat of 3 mm thick wall care putty including preparation of surface, complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 79 | M&L for two coats of oil bound distemper over a coat of primer on newly plastered surface of wall over a coat of 3 mm thick wall care putty including preparation of surface, complete all as specified and as directed. Please Enable Macros to View BoQ information |