| 1 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: |
| 2 | Asbestos Cement sheet |
| 3 | Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. |
| 4 | Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead: |
| 5 | Of sectional area 40 square centimetres and above |
| 6 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead: |
| 7 | Of area 3 sq. metres and below |
| 8 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : |
| 9 | Of area 3 sq. metres and below |
| 10 | Providing and fixing plain multipurpose cement board(Hight pressure steam cured) with suitable screws for cement particle board in ceiling etc. complete (frame work to be paid seperatately). |
| 11 | 6 mm thick Cement fiber board, Type-B, Category-III as per IS: 14862 :2000 |
| 12 | Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately). |
| 13 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5 mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 14 | Frame size 65 x 100 mm |
| 15 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. |
| 16 | 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 17 | Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). |
| 18 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 19 | Nominal concrete 1:3:6 or richer mix (including equivalent design mix) |
| 20 | Repair to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge. |
| 21 | Providing and laying Vitrified tiles in floor in diferent sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 22 | Glazed Vitrified tiles Matt/Antiskid finish of sizeSize of Tile 600 x 600 mm |
| 23 | Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge |
| 24 | 50 mm average thickness |
| 25 | Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. |
| 26 | Bars upto 12 mm diameter |
| 27 | Bars above 12 mm diameter |
| 28 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer- In-charge complete in all respect. |
| 29 | SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer |
| 30 | Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75 mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2). |
| 31 | 50 mm average thickness in 3 layers. |
| 32 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 33 | 125 mm |
| 34 | 100 mm |
| 35 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : |
| 36 | 300x16 mm |
| 37 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : |
| 38 | 250x10 mm |
| 39 | 100x10 mm |
| 40 | 12 mm cement plaster of mix: |
| 41 | 1:4(1 cement: 4 fine sand) |
| 42 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 43 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. |
| 44 | Two coats |
| 45 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade |
| 46 | Old work (Two or more coats applied @ 1.43 V/ 10 sqm) over existing cement paint surface |
| 47 | Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 48 | Old work (one or more coats) |
| 49 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 50 | One or more coats on old work |
| 51 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 52 | Two or more coats on new work |
| 53 | Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade: |
| 54 | One or more coats on old work |
| 55 | Providing and fixing pre-painted galvalume (PPGL) steel profile sheets AZ-150 of brand Tata Bluescope steel, Everest Industries Ltd., JSW Steel Ltd., Jindal India Ltd. or equivalent (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with aluminium zinc coating 150 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping aluminium screws (Xylan) of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 56 | Providing and fixing pre-painted galvalume (PPGL) steel profile sheets AZ-150 of brand Tata Bluescope steel, Everest Industries Ltd., JSW Steel Ltd., Jindal India Ltd. or equivalent (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with aluminium zinc coating 150 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling /self tapping aluminium screws complete |
| 57 | Pre-painted galvalume (PPGL) Steel Ridges plain (500 - 600mm) |
| 58 | Providing and fixing in position eaves or facia board with 18mm thick 30cm wide WPC Solid board including fixing with nuts and bolts etc, all complete as per the direction of Engineer-in-charge. |
| 59 | Extra for providing and fixing wind ties of 40x 6mm flat aluminium section. |
| 60 | Providing and fixing factory made single extruded WPC window shutters, fixing with 100mm stainless steel butt hinges including 4mm thick float glass panes etc all complete as per the direction of Engineer-in-charge. |
| 61 | 30mm thick WPC board |
| 62 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). |
| 63 | Superior hardwood Cat-II (A) |
| 64 | Providing and fixing 35mm thick glazed shutter for window with superior hard wood cat-II (A) using 10 Kg/Sqm 4mm thick glass and stainless steel butt hinges and screws including the cost of panelling as per the direction of Engineer-in-charge. |
| 65 | Superior hardwood cat-II (A) |
| 66 | Providing and fixing 4 mm dia. G.I. wire for adjusting hangers (upto 3000mm length), fixed to roof roof truss frames by tieing at both ends, complete as per direction of Engineer-in-charge. |
| 67 | Providing and fixing aluminium hooks and eyes ISI marked with necessary screws etc. complete. |
| 68 | 200mm |
| 69 | Providing and laying hollow cement concrete block walling 200mm thick consisting hollow block of size 400 x 200x200mm of mix 1:3:6(1cement :3 coarse sand:6 graded stone agg. 10mm nominal down size) having a crushing strength of 3.5N/mm2 at 28 days as per I.S. 2185 (Part-I) 1979 laid in cement mortar 1:6(1cement : 6 coarse sand). |
| 70 | Upto floor five level |
| 71 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of Stone Aggregate 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 72 | Providing cement concrete surface drain including earthwork excavation 10 cm thick base concrete and 15 cm thick side wall with 1:3:6 ( 1 cement : 3 Coarse sand: 6 graded stone aggregate of 40 mm nominal size) cement concrete finished with 1:4 (1 cement : 4 sand) a floating coat of neat cement inside the drain and its top and exposed surface including earthwork in excavation and disposed of surplus earth etc. |
| 73 | 15 X 15 cm Surface drain Please Enable Macros to View BoQ information |