| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group–C |
| 2 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 3 | Wiring for circuit /sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required a) 2x2.5sq.mm+1x2.5sq.mmearthwire |
| 4 | b) 2x 16sq.mm + 1 x6sq.mmearthwire |
| 5 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket out lets and 15/16 A modular Switch, Connections etc. as required. |
| 6 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket out let and 5/6 A modular switch, connections etc. as required. |
| 7 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20A\\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. |
| 8 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including Connections but excluding modular plate etc. as required. |
| 9 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ Recessed steel /PVC conduit as required a)3 x 1.5 sq. mm |
| 10 | 3 x 2.5 sq. mm |
| 11 | 3 x 4 sq. mm |
| 12 | Wiring for group controlled (looped) light point/fan point /exhaust fan point/ call bell point (without independent switch etc.) with 1.5sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group - C |
| 13 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 14 | Installation, testing and commissioning of pre-wired, LED fitting of all types, complete with all accessories and tube /lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 15 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface / recessed steel / PVC conduit as required.4pair |
| 16 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 25mm |
| 17 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribute on board, 240 V, on surface /recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, inter connections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 08 way, Double door |
| 18 | Supplying and fixing 5A to 32A rating, 240 /415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 19 | Supplying and fixing following rating, double pole, 240V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amps |
| 20 | Supplying and fixing following modular switch /socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet |
| 21 | Supplying and fixing call bell /buzzer suitable for single phase, 230 Volt, complete as required. |
| 22 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch connections etc. as required. (for light plugs to be use dinnonre side ntial buildings) |
| 23 | Installation, Testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30cm) with 1.5 Sq.mm FRLS PVC insulated, copper conductor, Single core cable including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 24 | LED Panel light 2x2 ft. (System lumen efficacy ≥120<135 lm/Watt)Supplying, Installation, Testing& Commissioning of Panel light 2x2ft., of following body material and construction as per IS : 10322with driver as per the requirement with Driver efficiency>85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD< 10%,P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating)<19, Flicker free, (flicker should be below 5 %), lifetime (LED, Driver& electrical circuitry), of minimum 50000Burning Hours with,70% of initial Lumen maintained till life ends, CCT3000°K/4000°K/ 5700°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching)<3, Maximum power Consumption should not more than the specified rating and Fixture 36watt |
| 25 | Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor,, class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS374:2019 fan i/c external connections with 1.5 sq. mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.1200 mm, service value ≥ 6.0 CM /Min /Watt, Air delivery 210CM / Min (Minimum) |
| 26 | LED Down lighter (COB Type) (System lumen efficacy ≥ 120 lm / Watt) Supplying, Installation, Testing & Commissioning of LED Recessed /surface Down lighter (Round/square /Rectangular) COB Type of following body material and construction as per IS :10322 with driver as per the requirement with Driver efficiency>85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temprange-50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD <10%, P.F.≥0.95, IP20,CRI>80 , UGR (Unified Glare Rating) <19, Flicker free (flicker should be below 5%), lifetime (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K /5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching)<3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BISstandard.Manufactures Word Mark /Name Engraved /Embossing/ Screen printing on housing.OEM must have it sown in house NABL lab setup for all testing facilities for LED fixtures. \\"complete in all respect i/c external connections with 1.5 sq mm FRLS/ HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120<135 lm/Watt output. LM 79 & LM 80 Test report and all testing required for LED fixtures as per BIS shall be submitted Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of 22watt Please Enable Macros to View BoQ information |