Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means(Hydraulic excavator)/manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50 m and lift upto 1.5 m ; disposed earth to be levelled and neatly dressed. All kinds of soil |
| 2 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as10 sqm on plan including disposal of excavated earth, leadupto50meterand lift upto 1.5m, as directed by Engineer-in-Charge. All kinds of soil : |
| 3 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed:2.8.1 All kinds of soil : |
| 4 | Filling of good earth including diging, loading, unloading, royality, carriage & spreading in proper lines and grades and consolidation with power road roller complete. |
| 5 | Consolidation of sub grade with PRR of 8-10 tonne capacity |
| 6 | Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete. In two layers |
| 7 | Dry brick pitching half brick thick including supply of bricks and preparing the surface complete. With common burnt clay (non modular) bricks of class designation 7.5 (in two Layers) |
| 8 | Providing and laying 75mm thick compacted bed of dry brick aggregate 40mm thick nominal size including spreading, well rammed, consolidated and grouted with fine sand including finishing smooth etc. complete as per direction of Engineer-in-charge |
| 9 | Supplying and Digging, carring by lorry,filling of black soil from Rajasthan as per lines cross sections, grade and camber including watering and consolidation in layers with 8-10 tonne power road roller complete (Finished work including material and labour) with carriages, lead, lifts loading and unloading complete. The work shall be got Executed in Presence of BCCI Certified Curator. |
| 10 | supply of Cricket Pitch Manual Roller -1.o Ton Capacity with Roller MS Sheet Thickness 15 to 18 mm Net Weight: 600 Kg, Gross Weight: 1000 Kg. (after filling with oil/water) with width of 3 feet and Extra small Iron Roller attached for better performance. |
| 11 | Making the opening for door/window/clerestory window in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground. |
| 12 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 13 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 14 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 15 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 16 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 17 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. M-25 grade reinforced cement concrete by using not less than 340 kg of cement per cum of concrete.All works above plinth level upto floor V level |
| 18 | Centering and shuttering including strutting, propping etc. and removal of formwork for: foundation footing |
| 19 | Centering and shuttering including strutting, propping etc. and removal of formwork for: Suspended floors, roofs, landings, balconies and access platforms. |
| 20 | Centering and shuttering including strutting, propping etc. and removal of formwork for: Lintel, beams, plinth beams, girders, bressumers and cantilevers. |
| 21 | Columns, pillars, piers, abutments, posts and struts. |
| 22 | Centering and shuttering including strutting, propping etc. and removal of formwork for: Stairs (excluding landings) except spiral staircases |
| 23 | Centering and shuttering including strutting, propping etc. and removal of formwork for Edges of slabs and breaks in floors and walls Under 20 cm wide |
| 24 | Centering and shuttering including strutting, propping etc. and removal of formwork for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc |
| 25 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete |
| 26 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 27 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 28 | Extra for brick work with common burnt clay bricks/cement concrete bricks insuperstructure above plinth level upto floor five level |
| 29 | Providing and laying autoclaved aerated cement blocks masonry with150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for separately). |
| 30 | Brick edging 7cm wide 11.4cm deep to plinth protection with common burnt clay (nonmodular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 Cement : 4 fine sand) and curing complete. |
| 31 | Providing and fixing 18mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement :4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels (Area of slab over 0.5 sqm) |
| 32 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. for seating tiers steps |
| 33 | Extra for fixing marble / granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. |
| 34 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately). Sal wood |
| 35 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws |
| 36 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured) |
| 37 | Providing and fixing decorative high pressure laminated sheet of plain/wood grain in gloss/matt/suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS: 2046 Type S including cost of adhesive of approved quality1 1.5mm thick |
| 38 | Providing and fixing 12mm compact laminate in 1830mm height with ISI 2046/95 certification without any joint. The solid compact laminate is based on thermostatic resin, homogenously reinforced with cellulose fiber and laminate on both side with suede finish, scratch and impact resistant. The Cubicle system will be equipped with heat and bacteria resistance to supply and install restroom system complete with Nylon Polyamide Grade 6 accessories with Aluminium powder coated D-Post,the modular shall possess 100% resistant properties towards: Water, Chemical,impact. A Accessories : PD-includes two vertical D-Post channel of 35mm each with 1830mm height available 3 in Aluminium powder coated (Grade 6063 Micron Aluminium) Hardware & fixing : a) D Post door channel (Black anodized) b)Hinges Adaptors c)Hinges - Gravity to close d) Privacy thumb turn C/w Occupancy Indicator e)Coat Hook f)Door Knob g) Rubber door stopper lining k) Screws & wall plugs All screws will of 304 grade in stainless steel with satin finish |
| 39 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 40 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete. : 250x10 mm |
| 41 | Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodized (anodic coating not less than grade AC 10 as per IS : 1868) aluminum lever handles of approved quality wi th necessary screws etc. complete. |
| 42 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete |
| 43 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, having brand logo embossed on the body/plate with double spring mechanism and door weight upto 125 kg for doors including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineerin- plate etc. complete as per the direction of Engineer-in-charge. With Stainless Steel cover plate minimum 1.25 mm thickness. |
| 44 | Providing and fixing aluminum extruded section body tubular type universal hydraulic door closer,(having brand logo with IS: 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete |
| 45 | Providing and fixing Pull Handle- H Type (316 Grade) back to back over glass/wood door with necessary SS screws of complete as per direction of engineer in charge 25mm x 600mm (DLine, Ozone, Dorma Make) |
| 46 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6mm, with 40mm dia, steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer, |
| 47 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer Using flats 30x6mm for diagonal braces and central cross piece |
| 48 | Providing and fixing ISI marked oxidized M.S. sliding door bolts with nuts and screws etc. complete 250x16 mm |
| 49 | Providing and fixing ISI marked oxidized M.S. tower bolt black finish, (Barrel type) with necessary screws etc complete. 250x10 mm |
| 50 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 51 | Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete. In colour such as White, Ivory, Grey, Fume Red Brown |
| 52 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufactures) with water absorption's less than 0.08% and confirming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete.Size of tile 60x60 cm |
| 53 | Grouting the joints of flooring tiles having joints of 3 mm width, using epox grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of tile 600x600 mm |
| 54 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 55 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, filling the joints with coarse sand etc. all complete as per direction of Engineer-in-charge. |
| 56 | Providing and fixing tiled False Ceiling of specified materials of size 595x595mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 gms/sqm both side inclusive ) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200 x600mm and secondary cross “T” of length 600mm and size 24x25 mm made of 0.30mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.30mm and laying false ceiling tiles of approved texture in the grid including, wherever, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27x37x25x1.6mm fixed to ceiling with 12.5mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanized butterfly level clips of size 85x30x0.8 mm spaced at 1200mm center to center along size 85x30x0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard manufactured from natural gypsum as per IS 2095 part-I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit. |
| 57 | Design, Supply, Fabrication and Erection Architectural Membrane System for custom designed to withstand the design wind pressure of 180 kg/sqmtr confirming to IS-875 part-III. (The system must pass the proof test at 1.5 times design wind pressure i.e. 285 kg/sqmtr PVDF coated fabric of the teaching width of 60mm with high frequency 20kw machine. The fabric structure shall be frame supported tensioned membrane Structure. The weight of fabric shall be Crosslinked Pvdf & Precontrant Serge Ferrari Coating 900 GSM or MEHLAR VALMEX MEHATOP N FR 1000 , SATTLER Atlas Type 111 or 1050 Gsm .The fabric shall have low elongation not more than 1..25% Characteristics under tension and shall assume an Anticiastic configuration. Structure that have designs incorporating. The fabric shall be polyester based with PVDF coating and Precontrant. The fabric shall be solvent resistant, UV resistant with 15 year warranty. The said work is to be got Executed only through specialized Agencies with Authorization Letter Specially for Said job as per instructions of engineer-in-charge, STRUCTURAL STEEL WORK Providing, Fabricating, Assembling, Hoisting, erecting and placing in position MS Built-up section/Tubular Structure (MS built-up section:- Rolled section & plates confirming to IS 2062, Tubular Structure:- made from steel hollow section (CHS/ RHS/SHS), ISI marked conforming to IS 1161/4923, (from TATA/ JINDAL/ Apollo) in the profile shape as per conceptual drawings with special plate connector, joints, Plates, hollow sections etc. for obtaining smooth - dimensional curvature. lding process with special plate connectors, pinion joints, plates, hollow sections, including Preparation of detailed fabrication and erection drawings of Structural steel work from design drawings, transportation from fabrication yard, cutting , threading, machining, leads and lifts up to all heights, tools & plants and necessary Cranes, erection machinery & tools, scaffolding etc. required for all operations involved to make structure of Tensile Membrane canopy. The structure has to be provided as per conceptual drawings of Tensile fabric profile, including all arch beam, curved lateral beams and bracings, vertical support columns, nodal joints, bases of columns and high tensile bolts (nuts and bolts to be paid separately). The complete structure to be blasted and coated with epoxy primer 2 coats and two coats Polyurethane applications work at all locations in required DFT (dry film thickness) for each coat as per technical specification and direction of Engineer-In- Charge.(The rate include the cost of scaffoldings, staging, hoisting, cranes, labor, tools and plants & equipment, transportation of material from workshop to site, assembling the segments and erection of the same) The quote rate shall include all design, engineering & shop drawing approval from Architect & consultant. The quote rate shall include safety code compliance as per contract requirements. Complete as per Drawing / Detail & as per particular/ technical specifications and as per the directions of Engineer-in-charge. (Rate includes cost of fabric, patterns, forming, cutting, fabrication, hot weld stitch of fabric, Transport to the site, assembling and installation with GI strands, hardware, EPDM gasket and required accessories, STEEL STRUCTURE, GUSSET PLATES AND ANCHOR BOLTS wherever required complete including lifts up to all heights, tools & plants, and necessary scaffolding etc. required for al. |
| 58 | Providing and fixing on wall face un-plasticized Rigid PVC rain waterpipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single socketed pipes 110 mm diametre |
| 59 | 12 mm cement plaster of mix :1:6 ( 1 cement : 6 coarse sand ) |
| 60 | 6 mm cement plaster to ceiling of mix : |
| 61 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick |
| 62 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface. |
| 63 | Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work |
| 64 | Finishing walls with textured exterior paint of required shade on New work (two or more coats applied @ 3.28 liter/10sqm) over and including base coat of exterior primer applied @ 2.20kg/10sqm |
| 65 | Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm) |
| 66 | Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) Powder coated aluminum (minimum thickness of powder coated 50 microns) |
| 67 | Aluminium work For shutters of doors, windows & ventilators including providing and fixing hinges l pivot and making provision and fixing of fittings wherever required including the cost of EPDM rubber gasket required. |
| 68 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineerin- charge. (Cost of aluminum snap beading shall be paid in basic item.)With floating glass panes of 4.0 mm thickness (weight not less than 10.00 kg / sqm) |
| 69 | Providing and fixing fly proof wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions all complete. With Galvanized M.S. Wire gauge with wire of dia 0.63 mm With 12 mm mild steel U beading |
| 70 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete 125 mm |
| 71 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete 250x10 mm |
| 72 | Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 100x10 mm |
| 73 | Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 100 mm |
| 74 | Providing & fixing 100 mm aluminium Hook with eye 100mm long |
| 75 | Providing and installation of Vertical blinds complete in all aspects.The vertical blinds shall suit all environments, Using a sleek, shallow wide body system, operation should be smooth and simple allowing the blinds to tilt, turn or stack to either side of the window for complete light control with Novara fabric having compostion of 3ply Vinyl / 1ply Fiberglass ( 72% Vinyl + 28 % Fiberglass)Fabric width (Vanes/Strip wdth 089MM) overall fabric thicness should be 0.33mm (+/- 5%) with light fastness should be of Grade >6 as per SGS certification to BS EN ISO 105-B07 standards. Dying Process of the fabric should be Yarn Dyed / Acrylic Coated wth Fire Retardant Standard BS5867-1980 Part 2 having Special Property of Easy wipe ( in case of stain) with wet cloth. Control Unit should be Injection moulded with high quality plastic used with Head Rail of Shallow wide body system in white aluminium head rail. Width: 44.5mm & Height: 25mm. Fabric Bonding should be Depending upon fabric composition, fabric should be bonded by Fusing or Sewing both top and bottom fold Brackets for Head Rail Steel Powder coated ceiling or wall brackets in White or Black finish.Operating Chain White plastic chain enhancing the look of blinds and ease of operation with chain connector and polycarbonate stopper of O/D:6mm & I/D:4mm. Average number of balls on chain are 50 per foot length. Bottom Weight with Link ChainTo keep straight finish moulded bottom weight for the fabric having Bottom link chain to keep all strips together.Cord Weight Colour co-ordinated plastic cord weight to stabalise the operating chain in White or Black based on accessories colour. Blinds should be installed by professional installers in accordance with the instructions of Engineer in charge with original and recommended support brackets & fasteners. Blinds should be installed leaving adequate clearance from obstructing objects like handles and using a spirit level to ensure smooth operation of blinds.Blinds should be measured from Left to Right across the EVO system or bracket to bracket if EVO systems are not used. The drop of the blind should be measured from bracket to the bottom of the bottom bar. D Decor, Johnson and Hunter Dogulas or eq make |
| 76 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot &double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). |
| 77 | Providing and fixing Heavy Duty Double Glass Door Lock with striking box Ozone OPL/4-A/4-B or eq. make |
| 78 | Providing and laying integral cement based water proofing treatment including preparation of surfaces as required for treatment of roofs, balconies, terraces etc consisting of following operations. a) Applying a slurry coat of neat cement using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC Slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/ Brick Bats 25mm to 115mm size with 50% of Cement mortar 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineerin-charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of Junctions of walls and slabs) c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge. d) finishing the surface with 20mm thick joint less cement mortar of mix 1:4(1 cement: 4 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm/sq 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineerin-charge. With average thickness of 120mm and minimum thickness at khurra as 65 mm |
| 79 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement: 3 fine sand) as per standard design. In 75x75 mm deep chase. |
| 80 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement: 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 81 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with with water proofing cement compound @ 0.253kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm . This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. |
| 82 | CARRIAGE OF MATERIALS By Mechanical Transport including loading, unloading and stacking Coarse Sand |
| 83 | CARRIAGE OF MATERIALS By Mechanical Transport including loading, unloading and stacking Stone aggregate below 40 mm nominal size |
| 84 | CARRIAGE OF MATERIALS Brick |
| 85 | Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge |
| 86 | Providing & fixing white vitreous china water less urinal of size 600 x 330 x 315 mm having antibacterial /germs free ceramic surface, fixed with cartridge having debris catcher and hygiene seal |
| 87 | Providing and fixing urinal partition with frosted safety glass of 8mm thick of size 900mm(height) x 450 mm( width) corner chamfered fixed in brick wall with stainless steel clips of grade 304 all complete. |
| 88 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer |
| 89 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings |
| 90 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040mm bowl depth 225mm |
| 91 | P/F 8mm dia C.P/S.S jet with flexible tube up to 1mter long with S.S triangular plate to eurepean type W.C of approved qaulity and make. |
| 92 | Providing and fixing CP brass health faucet with tube and hook etc. complete as per direction of Engineer-in-charge |
| 93 | Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. 15 mm nominal dia |
| 94 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete: Semi rigid pipe 32 mm dia |
| 95 | Providing and fixing 600x120x5mm glass shelf with edges round off supported on anodized aluminum angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs, etc. complete |
| 96 | Providing and fixing toilet paper holder C.P. brass |
| 97 | Providing & fixing cockcroch trap S.S. grating of approved design for floor traps etc. including setting in floor with cement mortar. 100 mm dia . |
| 98 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour: Waste coupling 31mm of 79 mm length and 62 mm breadth weighing not less than 45gms |
| 99 | Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangements of approved quality and colour, weighing not less than 88 gms |
| 100 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour: 600 mm long towel rail with total length of 645 mm, 78 mm wide and effective height of 88 mm, weighing not less than 190 gms |
| 101 | Providing and fixing beveled edge 8 mm mirror of superior glass (of approved quality) complete with Spacer & C.P. brass screws and washers complete. |
| 102 | Providing and Fixing in position storage type hot water electrical heaters with copper container, insulation, and stove-enamelled M.S jacket, thermostatically controlled immersion heater, with pilot lamp, 15/20mm dia inlet with non-return valve and 15/20mm dia outlet including making connections complete in all respect. (wall mounted with suitable M.S bolts and nuts) (Make -Venus/ havells/crompton) Capacity 25 litres |
| 103 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. External work including trenching, refilling etc. 50mm nominal outer dia pipes |
| 104 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge.Internal work-exposed on wall, including fixing the pipe with clamps at 1.00 meter spacing 50mm nominal outer dia pipes. |
| 105 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge.Internal work-exposed on wall, including fixing the pipe with clamps at 1.00 meter spacing 40mm nominal outer dia pipes |
| 106 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work-exposed on wall, including fixing the pipe with clamps at 1.00 meter spacing 25mm nominal outer dia pipes. |
| 107 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall, etc. 20mm nominal outer dia pipes. |
| 108 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall, etc. 15mm nominal outer dia pipes. |
| 109 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 40 mm nominal bore |
| 110 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 50 mm nominal bore |
| 111 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 25 mm nominal bore |
| 112 | Providing & fixing 2.0 HP water pump including starter, wire and all necessary fitting complete as per direction of engineer incharge Crompton, CRI or equivalent make. |
| 113 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 114 | Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931 |
| 115 | Providing and fixing 15 mm nominal bore C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms |
| 116 | Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 |
| 117 | Providing and fixing un plasticized P.V.C. connection pipe with PTMT nuts, collars and bush of approved quality and colour 15 mm nominal bore with 45 cm length |
| 118 | Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sewerage waste discharge system (IS:13592 : 1992 Marked) of approved quality /make supreme, jain pipes, sudhakar, prince or equivalent make 100 mm dia |
| 119 | Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sewerage waste discharge system (IS:13592 : 1992 Marked) of approved quality /make supreme, jain pipes, sudhakar, prince or equivalent make 75mm diameter : |
| 120 | Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sewarage waste discharge system (IS:13592 : 1992 Marked) of approved quality /make Bend of required degree with access door, 100 mm dia |
| 121 | Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sewarage waste discharge system (IS:13592 : 1992 Marked) of approved quality /make Bend of required degree with access door, 75 mm dia |
| 122 | Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sewarage waste discharge system (IS:13592 : 1992 Marked) of approved quality /make Plain bend of required degree. 100 mm dia |
| 123 | Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sewarage waste discharge system (IS:13592 : 1992 Marked) of approved quality /make Plain bend of required degree. 75 mm dia |
| 124 | Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sewarage waste discharge system (IS:13592 : 1992 Marked) of approved quality /makeHeel rest sanitary bend 100 mm dia |
| 125 | Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sewarage waste discharge system (IS:13592 : 1992 Marked) of approved quality /make Heel rest sanitary bend 75 mm dia |
| 126 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group-C (Primary point ) |
| 127 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 128 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 129 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 130 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 131 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required. |
| 132 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire For 6A Light Circuit Point |
| 133 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire For 6A UPS & Light Circuit Point |
| 134 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire For 16A Power Circuit Point |
| 135 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required2 X 6 sq. mm + 1 X 6 sq. mm earth wire For 25A Power Circuit Point |
| 136 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required4 X 10 sq. mm + 2 X 6 sq. mm earth wire For Light & Power DB Submain wire |
| 137 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required4 X 16 sq. mm + 2 X 6 sq. mm earth wire For UPSDB Submain wire |
| 138 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way , Double door |
| 139 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way (4 + 24), Double door |
| 140 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way (8+36) Double door |
| 141 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole (6/32 Amps) |
| 142 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 143 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps |
| 144 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 100 amps |
| 145 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps |
| 146 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps |
| 147 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 148 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 149 | LED Panel light 2x2 ft., (System lumen efficacy >135 lm/Watt) 36 wattSupplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz,Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80,UGR (Unified Glare Rating) < 19, Flicker free,(flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard.Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management:heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm |
| 150 | Supply installation testing and commissioning of 1200 mm Ceiling Fan 3 Star Rated with Voltage Range 90 V to 300 V,Min. Air Delivery 212 CMM,Service Value 5.3 Cu.m/min/watt,Aluminium Blades ,including wiring the down rods of standard length(Upto 45 cm)with 1.5 sq.mm FR PVC insulated,copper conductor,single core cable including providing and fixing phenolic laminated sheet cover on the Fan Box etc as Required. |
| 151 | Installation, testing and commissioning of 200 mm sweep exhaust fan with robust motor, gravity shutters with speed rating of 1350 revolution per minute complete with all accessories etc. directly on ventilator , including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. Firm has to submit originallity certificate of material from OEM or Authorized Distributor with 05 years of warranty. |
| 152 | Supply installation testing and commissioning of IP:20 Decorative Light 10W-12 W +- 1 W LED Surface Mounted 2 ft. with system lumen efficacy of 100 lm/W and P.F >0.9 THD <20% CCT 6500K,CRI 80 .The LED should have life of 50000 Burning Hours at L70.The input voltage shall be 150 V to 270 V.The fixture should have inbuit surge protection of 2KV.Certification-LM 79 and LM 80.The test report should be from Govt. Approved Lab/inhouse NABL Lab. |
| 153 | Installation testing and comissioning of linear surface wall mounted 36 watt light luminaire with Luminous efficiency of luminaire 100 lm/W; color rendering index Ra > 80; minimum system lumen output of 4000 lumens and maximum system wattage of 12W; Dimension :- 1200 mm Body of extruded aluminium profile and polycarbonate cover. |
| 154 | 200 watt LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt) Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, |
| 155 | Supplying, installation, testing and commissioning of 1.5 Ton Inverter type Split ACs (copper) (3 star) Hot/ Cold (all weather) type of minimum capacity following sizes as 1etailed below. Each unit must provide cooling dehumidification, be operatable via remote control, operate at 220-240 V AC supply with latest in vogue features. ALONG WITH necessary stand for outdoor unit and socket and modular MCB switch fixing recessed in wall and Repairs made to wall whereever required. Warrantee.-a). Warrantee shall be provided for 12 month from the date of installations.The compressor shall be warranted for 5 years from the date of installation |
| 156 | Supplying, installation, testing and commissioning of automatic voltage stablizer copper wound wall mounted ,single phase range of 90-240 V along with wall mounted brackets & fittings 4KVA |
| 157 | Supply and fixing Sine Wave Inverter 2000 VA for Double Battery with necessary connection and accessories like Socket and modular plates for connection in existiong electirc fitting as per the direction of Engineer Incharge |
| 158 | Supply and fixing battery 12 volt Tubular 150 AH with 36 month Gurranty |
| 159 | SUB-HEAD-VII LT DISTRIBUTION PANELSupply,Installation, Testing and Commissioning of dust, damp and vermin proof free floor /wall mounted, Indoor/ outdoor type factory built sheet steel enclosed modular construction extendable panel, suitable for operation on 415 ±10% volts, 50 Hz AC 3 phase 4 wire system fabricated out of suitable sized square tubular section and covered with CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, complete with Aluminium bus bars, inter-connection with copper conductor wires / aluminium strips, neutral links, earth bus etc. including control wiring with 1.5sqmm. & 2.5sqmm. PVC insulated FRLS copper conductor S/C cable for voltage & current respectively, cable alleys, cable gland plates in two half, etc. necessary metering protections & indications and mounted with the following switch gears etc. complete as required. (Each MCCB will have variable current setting for over current and short circuit, front extended lockable handle, pad lockable in off position, indication light for ON, shrouding on incomer side, termination shall be suitable for aluminiumbus bars. All MCCBs of 250 A and above shall be microprocessor based only.ELECTRICAL PANEL Ics = 35KA Incomer 1 No. Incomer 160Amps 4P MCCB with microprocessor basedreleases for O/C, S/C, 3 Nos. phase indicating lamps to show the incoming power with control 2A TP MCB,and 1 no. digital multifunction meter with matching cast resin CT's.Bus Bar One set of TPN, AL. bus bar rated 200Amps (after considering necessary deratings of 80%) forphases and neutral for half capacity of phases.The outgoing feeders are as follows :2Nos. 100Amps TP feeders each having one number 100 Amps TP MCCB.7Nos. 40/63Amps 4P feeders each having one number 40/63 Amps 4P MCB.1Nos. 32Amps 4P feeders each having one number 32 Amps 4P MCB.1 set of complete wiringELECTRICAL PANEL as describe above and shown in SLD. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail