| 1 | Civil Works |
| 2 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level upto floor five level excluding cost of centering, shuttering, finishing and reinforcement : |
| 3 | 5.2.1 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 4 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases above plinth level upto floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 5 | Centering and shuttering including strutting, propping etc. and removal of form for: |
| 6 | 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers. |
| 7 | 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 8 | Reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete. Above Plinth level |
| 9 | 5.20 A.2 Thermo-Mechanically Treated bars |
| 10 | Half brick masonry with 1st class common burnt clay FPS (non-modular) bricks in superstructure above plinth level upto flooe V level in |
| 11 | 6.9.2 Cement mortar 1:4 ( 1 cement : 4 coarse sand). |
| 12 | Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately : |
| 13 | 9.1.2 Local best quality Uningthou wood |
| 14 | Providing wood work in frames of false ceiling, partitions etc. sawn and put up in position : |
| 15 | 9.2.1 Local best quality Uningthou wood. |
| 16 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows including ISI marked M.S butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. |
| 17 | 9.4.1 Local best quality Teak wood |
| 18 | 9.4.1.1 35 mm thick shutters |
| 19 | Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets: |
| 20 | 9.20.1 20 mm dia (heavy type) |
| 21 | Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10 x 15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) |
| 22 | Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : |
| 23 | 9.41.1 125x64x2.50 mm |
| 24 | Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete (best make of approved quality). |
| 25 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 26 | 9.63.1 300x10 mm |
| 27 | Providing and fixing aluminium handles, ISI marked,anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 28 | 9.65.1 125 mm |
| 29 | Providing and fixing nickel plated MS pipe curtain rods with nickel plated brackets : |
| 30 | 9.20.1 20mm dia. (heavy type) |
| 31 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators side /top /centre hung with beading and all members such as F7D,F4B,K11B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and rivetted, including providing and fixing of hinges, pivots,including priming coat of approved steel primer,but excluding the cost of other fittings,complete all as per approved design. (sectional weight of only steel members shall be measured for payment). |
| 32 | 10.11.1 Fixing with 15x3mm lugs, 10cm long, embedded in cement concrete blocks 15x10x 10cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) |
| 33 | 15 mm cement plaster on rough side of single or half brick wall of mix:- |
| 34 | 13.2.1 1:4 (1 cement : 4 fine sand) |
| 35 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption's less than 0.08% and conforming to IS:15622 of approved make in all colours and shades laid on 20mm thick cement mortar 1:4 (1 cem : 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete. |
| 36 | 11.32.1 Size of tile 600x600 mm |
| 37 | Cement plaster skirting (upto 30cm height) with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement. |
| 38 | 11.5.1 18mm thick |
| 39 | Tile work in skirting, risers of steps and dado (upto 2m height) over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry @ 3.3kg/sqm including pointing in white cement mixed with pigment of matching shade complete.Tile work in skirting, risers of steps and dado (upto 2m height) over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry @ 3.3kg/sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 40 | 11.15.1 Marble tiles (polished) Raj nagar |
| 41 | 11.15.1.1 8mm thick |
| 42 | Providing and fixing insulating board ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately). |
| 43 | 12.22.1 Natural color insulating board |
| 44 | 12.22.1.1 12 mm thick |
| 45 | Providing and applying white cement based putty of average thickness 1mm of approved quality brand and manufacture, over the plastered surface to prepare the surface even and smooth complete. |
| 46 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade |
| 47 | 13.29.1 New work (two or more coats) over and including priming coat with cement primer:- |
| 48 | Finishing walls with textured exterior paint of required shade : |
| 49 | 13.33.1 New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm. |
| 50 | Applying priming coat:- |
| 51 | 13.37.1 With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 52 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade |
| 53 | 13.45.1 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 54 | Steel work in built up tubular (round, square or rectangular tubes etc.) trusses etc. including cutting, hoisting fixing in position and applying a priming coat of approved steel primer, including welding and bolted including special shaped washers etc. complete. |
| 55 | 10.16.3 Electric resistance or induction butt welded tubes. |
| 56 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required with |
| 57 | 12.46.3 Precoated galvanised iron profile sheets 0.50 mm thick |
| 58 | Providing and fixing precoated galvanised steel sheet roofing accessories, Zinc coating 120gsm as per IS:277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyster top coat 15-18 microns using self drilling/tapping screws or with polymer coated J or L hooks, bolts and nuts and or GI seam bolts and nuts GI plain and bitumen washers complete: |
| 59 | 12.47.1 Ridges plain (500-600mm). |
| 60 | 12.47.1.3 Precoated galvanised iron profile sheets 0.50 mm thick |
| 61 | 12.47.6 Gutter (600mm over all girth) |
| 62 | 12.47.6.3 Precoated galvanised iron profile sheets 0.50mm thick |
| 63 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : |
| 64 | 16.2.1 W.C. pan with ISI marked white solid plastic seat and lid. |
| 65 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes respectively with utomatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : |
| 66 | 16.4.4 Range of four half stall urinals with 10 litre P.V.C. automatic flushing cistern |
| 67 | Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C. automatic flushing cistern, with fittings, standard size G.I. / PVC flush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete, including painting of fittings and cutting and making good the walls and floors etc. wherever required : |
| 68 | 16.6.5 Range of four squatting plates with 10 litre P.V.C. automatic flushing cistern |
| 69 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required: |
| 70 | 16.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 71 | Providing and fixing 8mm dia C.P./S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 72 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 73 | 16.26.1 Semi rigid pipe 40 mm dia |
| 74 | Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 75 | Providing and fixing toilet paper holder: |
| 76 | 16.29.1 C.P. brass |
| 77 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. |
| 78 | 16.34.1 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms. |
| 79 | Providing and fixing Polyethelene-Aluminium- Polyethelene PE-AL-PE Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 metre spacing. This includes the costs of cutting chases and including testing of joints complete as per direction of the engineer in charge. |
| 80 | Concealed work, including cutting chases and making good the wall etc. |
| 81 | 17.2.2 20mm nominal outer dia. Pipes |
| 82 | 17.2.4 32mm nominal outer dia. Pipes |
| 83 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. |
| 84 | External work |
| 85 | 17.3.6 50 mm nominal outer dia Pipes |
| 86 | Providing and fixing CP brass bib cock of approved quality conforming to IS:8931 : |
| 87 | 17.24.1 15 mm nominal bore Please Enable Macros to View BoQ information |