| 1 | Surface dressing n.exc 15cm deep in hard dense soil complete all as specified and directed |
| 2 | Excavation in trenches in any type of soil, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation etc. or for shafts, wells cesspits, manholes, pier hole etc. and getting out, complete all as specified and directed. |
| 3 | providing cement concrete type D2, 1:4:8 (using 40 mm graded stone aggregate), as in foundations, filling and mass concrete etc., complete all as specified and as directed |
| 4 | Reinforced cement concrete type 1:1½:3 (nominal mix, using 20mm graded crushed stone aggregate) as in Foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc. complete all as specified and directed |
| 5 | Material and labour for reinforced cement concrete 1:1½:3 (nominal mix, using 20mm graded crushed stone aggregate) as in Columns, pillars, piers, posts and struts complete all as specified and directed. |
| 6 | Reinforced cement concrete , 1:1½:3 (nominal mix,type A-1, using 20mm graded crushed stone aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span , complete all as specified and directed. |
| 7 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work, vertical or to batter , rough finished, complete all as specified and directed. |
| 8 | Formwork to sides of pillars, posts, struts, piers, columns and stanchions rough finished surface of flat concrete complete all as specified and directed. |
| 9 | Form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for roughly finished flat surfaces of concrete, all as specified. |
| 10 | Form form work to soffits of suspended slabs such as roof slabs rough finished surface of concrete flat not exc 200mm thick (horizontal or sloping), complete all as specified and directed. |
| 11 | MS TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed ) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 12 | Mild steel TMT bars 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips as in stirrups, spacers, binders etc, complete all as specified & directed. (Stirrups) |
| 13 | Brick work with sub class ‘B’ bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:6 complete all as specified & directed. |
| 14 | Rendering 15mm thick in Cement and Sand mortar 1:4 over brick or concrete surfaces finished even and fair without using extra cement complete, all as specified and directed. |
| 15 | Preparation of new surfacs and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified and directed. |
| 16 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc.25cm thick each layer of soil all as specified. |
| 17 | Removal of excavated material to distance exceeding 50 metre but not exc 250 m and depositing where directed at a level not exceeding 1.5 metre above the starting point , complete all as specified and directed. |
| 18 | Providing 9 meter high flag post made of 100 mm dia, stainless steel tubular pole as flag post, including necessary base plate, GI strings as tying/fixing accessories to pole complete with provision of hoisting/raising the flag, complete all as specified and directed. |
| 19 | Providing 6 meter high flag post made of 100 mm dia, stainless steel tubular pole as flag post, including necessary base plate, GI strings as tying/fixing accessories to pole complete with provision of hoisting/raising the flag, complete all as specified and directed. |
| 20 | Mild steel screw bolts 16 to 20 mm (machine made) with hexagonal or square head one end and screwed the other, or screwed both ends each screwed end to be fitted with washers and one hexagonal or square nut, dia of shank exc 22.5 cm but not exc 30 cm long, complete all as specified and directed. |
| 21 | Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) with riveted, bolted or welded attachment using Fe 410-W (Gde-E- 250) quality- A complete all as specified and directed. |
| 22 | 150 mm bore MS pipe, heavy grade with all fittings and laid in floor/ceilings or fixed to wall, complete all as specified and directed. |
| 23 | 18-20 mm thick Granite (of any type), (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade, over and including 15mm thick screed in cement mortar 1:6 complete all as specified and directed. |
| 24 | Endura tiles of matte finish of size 300 x 300 x15 mm thick anti slip, set and jointed in neat cement slurry with grey cement with pigment to match the colour of tiles, glossy finish, laid over and including 20 mm thick screed bed in CM 1:4, complete all as specified and directed. |
| 25 | Point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 2.5 Sqmm , 1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 2.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising of One light point controlled by one switch complete all as specified and directed. |
| 26 | Modular switch one way, 6 amps, one module, 230 volts, single pole, complete all as specified and directed. |
| 27 | MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 08 way SPN with 200 Amps busbar 240V, completed all as specified and directed. |
| 28 | MCB ,SP , 240 volt, 6Amps to 32Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 29 | MCB, SPN , 240 volt, 32Amps, 10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed |
| 30 | LED flood light fitting 120 Watt 5700K outdoor type, cool white with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrision resistant including thermal management in multiple optics complete with IP 65 protection complete all as specified and directed. |
| 31 | 25mm outer dia, double walled corrugated (DWC) HDPE duct pipe conforming to IS 14930 Part-II with anti rodent and non flame propogating properties of approved colour with fittings for cable protection from approval make complete , all as specified and directed |
| 32 | XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmm, 2 core, laid in trenches/floor, fixed to pole/wall all as specified and directed. |
| 33 | Bollard light of 10 watt, warm white, complete all as specified and directed.Make: Jaquar cat part No OBL-GLY-LBLDDSC010XW or equivalent make as specified in PS |
| 34 | Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, burried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), complete including dismantling of old earthing, all as specified and directed. Note(s) :-(i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm.(ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit.(iii) Rate shall include earth lead and protection pipe of length 7.5m(iv) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt.(v) unit rate including protection pipe and GI wire 4.00mm dia from top to earth plate upto 7.5 meter |
| 35 | Post top lantern LED type, 20 watt, 230 volts, AC outdoor type with decorative post top for 360 degree indirect light IP65 protection with impact and corrosion resistant, with driver and lamp, complete , all as specified and directed Please Enable Macros to View BoQ information |