Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Demolition of brickwork masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all specified and directed by E/I |
| 2 | Dismantling of Stone slabs and tiles of anydescription or thickness in floors, aprons etc. Laid, bedded and pointed in any mortar complete all specified and directed by E/I |
| 3 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out of Soft/loose soil complete all specified and directed. |
| 4 | Returning, filling, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick of Soft/loose soil complete all specified and directed. |
| 5 | M&L for earth filling backside wall along with flooring including spreading and levelling including watering well raming etc. in layer and exc 25 cm thick and rough excavated material exc. 1.50 km but n exc. 5 km and depositing where directed. |
| 6 | M&L for anti-termite treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all specified and directed by E/I |
| 7 | M&L for anti-termite treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all specified and directed by E/I |
| 8 | M&L for anti-termite treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all specified and directed by E/I |
| 9 | M&L for anti-termite treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all specified and directed by E/I |
| 10 | M & L Cement concrete in foundations, filling and mass concrete Type D2 1:4:8 (40 mm graded aggregate) |
| 11 | M&L for RCC work with cement approved coarse sand and 20mm graded aggregates approved stone ballas confirming M-20 mixed in foundation / footing, plinth beam etc. excluding steel reinforcement and formwork complete all specified and directed. |
| 12 | M&L for RCC work with cement approved coarse sand and 20mm graded aggregates approved stone ballas confirming M-20 mixed in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves excluding steel reinforcement and formwork complete all specified and directed. |
| 13 | M&L for RCC work with cement approved coarse sand and 20mm graded aggregates approved stone ballas confirming M-20 mixed in Beams, cantilevers, bressummers, lintels over 1.5m span excluding steel reinforcement and formwork complete all specified and directed. |
| 14 | M&L for RCC work with cement approved coarse sand and 20mm graded aggregates approved stone ballas confirming M-20 mixed in Columns, pillars, piers, posts and struts excluding steel reinforcement and formwork complete all specified and directed. |
| 15 | M&L for RCC work with cement approved coarse sand and 20mm graded aggregates approved stone ballas confirming M-20 mixed in Chajjas excluding steel reinforcement and formwork complete all specified and directed. |
| 16 | M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in reinforcement complete all specified and directed |
| 17 | M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter finished surface fair and even complete all specified and directed. |
| 18 | M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) finished surface fair and even complete all specified and directed. |
| 19 | M&L Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide (Where RCC/PCC band in walls, spanning and opening, the formwork soffit only shall be paid for under item 07010) finished surface fair and even complete all specified and directed. |
| 20 | M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. finished surface fair and even complete all specified and directed. |
| 21 | M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions etc. finished surface fair and even complete all specified and directed. |
| 22 | M&L for Formwork to Formwork to chullah hoods, chajjas, troughs and similar items including edges complete all specified and directed. |
| 23 | M&L for Brickwork with subclass ‘A’ bricks, straight or curved on plan exc 6m mean radius built in cement motar 1:6 complete all specified and directed. |
| 24 | M&L for Brickwork with subclass ‘A’ bricks, straight or curved on plan to any radius built in half brick thick walls built in cement motar 1:4 complete all specified and directed. |
| 25 | M&L for 12mm thick cement plastring in 1:6 cement motar on fair faces of brick work or concrete surface finished even and smooth without using extra cement on surface complete all specified and directed. |
| 26 | M&L for Screed bed or bedding layer of mortar 15 mm thick Cement plaster with 1:4 mortar for laying floor finishes complete all specified and directed. |
| 27 | M&L for Virified Ceramic tiles light shade 10 mm thick (square/rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed inwhite or coloured cement to match complete all specified and directed. |
| 28 | M & L of Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete complete all specified and directed. |
| 29 | S&F of Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of splain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing with both side Prelam PVC sheet used instead of Plain colour PVC sheet. Stile and rails feathered at edges complete all specified and directed. |
| 30 | S&F of Extruded aluminium alloy handles, fabricated type, anodised with size of handle 150mm long complete all specified and directed. |
| 31 | S&F 200 mm long Aluminium anodised, barrel tower bolts of ex-truded section and fixed complete all as specified and directed. |
| 32 | S&F 250mm long aluminum alloy, anodised sliding bolt with hasp stable bolt type stove enameled black, with bright bolt not less than 12mm dia and including a minimum 06 Nos bolts and nutls. Complete all as specified and directed. |
| 33 | S & F Continuous (piano) hinges, mild steel, bright finish or electrogalvanised. |
| 34 | S&F of Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing with single side prelam PVC sheet used instead of Plain colour PVC sheet & edges will be painted to match with prelam sheet complete all specified and directed by E/I. |
| 35 | M&L two coat oil bound distemper and preparation of newly plastered surface of wall for internal side ceiling complete all specified and directed by E/I. MAKE- APEX |
| 36 | M&L for cement paint i.e. two coat of exterior emulson paint and preparation of newly plastered surface outside complete all specified and directed by E/I. |
| 37 | M&L for 3mm thick wall care putty on wall |
| 38 | M&L for Preparation of New steel and iron surface of any description, over 10cm in width or girth and apply two coat of synthetic enamel paint over coat of red oxide primer complete all specified and directed. |
| 39 | S&F of Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match. |
| 40 | S&F of Glazed ceramic coloured tiles tiles in vertical surface 350x 250x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match. |
| 41 | Plumbing work |
| 42 | S&F of 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed by E/I |
| 43 | S&F of 75mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed by E/I |
| 44 | S&F of 110mm dia PVC (SWR) bends any radius |
| 45 | S&F of 75mm dia PVC (SWR) bends any radius |
| 46 | S&F of PVC (SWR) vent cowl bore in 110mm |
| 47 | S&F of 110mm bore in PVC (SWR) couplers |
| 48 | S&F of 75mm bore in PVC (SWR) couplers |
| 49 | S&F of 110mm PVC (SWR) WC connector with lip ring |
| 50 | S&F of 110mm PVC (SWR) 'P’ trap |
| 51 | S&F of Bottle trap of PTMT having minimum water seal of 25mm .(Minimum weight 32mm-260gms/ 40mm-270 gms) |
| 52 | S&F of PVC (SWR) floor trap, plain with grating including jointing with solvent cement with 75mm dia |
| 53 | S&F of sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x160mm complete all as specified and directed by E/I |
| 54 | S&F of Vitreous China, semi-pedestal pattern (Anglo-Indian Type) including 10 litres, cast iron, valveless. syphonic action type, flushing cistern, high level, with inlet, ball valve, float, chain and pull, and brackets complete all as specified and directed by E/I |
| 55 | Supplying and laying of 16mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 56 | Supplying and laying of 20mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 57 | Supplying and laying of 25mm dia CPVC pipes CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 58 | S&F of 500 liter Rotational moulded polye thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed by E/I |
| 59 | S&F of 15mm dia Plug type bib taps, cast iron, screwed for iron pipe and fixed complete all as specified and directed by E/I . |
| 60 | S&F of 15mm dia Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts,screwed for iron pipe and fixed complete all as specified and directed by E/I . |
| 61 | S&F of 25mm dia Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by E/I . |
| 62 | S&F of 15mm dia Angle stop valve of PTMT any colour high pressure screwed for iron pipe and fixed with Minimum weight 15mm-90gms) complete all as specified and directed by E/I . |
| 63 | S&F of Shower arm 15 mm size, 195mm long with bend of 45degree with flange of PTMT any colour with Minimum weight 40gms complete all as specified and directed by E/I . |
| 64 | S&F of Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats with Minimum weight 300gms complete all as specified and directed by E/I . |
| 65 | S&F of Liquid soap container of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats with Minimum weight 105gms complete all as specified and directed by E/I . |
| 66 | M & L of 100mm with Cement concrete 1:3:6 type C-2 Concrete bed to drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested complete all as specified and directed by E/I . |
| 67 | S&F of precast cement concrete Type B1 1:2:4 (20mm graded aggregate) cover slabs (for man holes etc.) jointed in cement mortar 1:6 etc . complete in all respect as specified. |
| 68 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out Soft/loose soil. |
| 69 | Supply & Spreading Hardcore Broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete in all respect as specified |
| 70 | M&L for 75 mm thick Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) for c.c. flooring complete all specified and directed. |
| 71 | 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers |
| 72 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. |
| 73 | Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length. |
| 74 | Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion elded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. |
| 75 | Using R2 series with frame (70 mm & above) x (40 mm & above) & both glazed and fly screen sash (25 mm & above) x (50 mm & above) with zinc alloy (zamak) powder coated touch locks with hook. (Height upto 1.2 metre). |
| 76 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”: 22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 77 | Repair work |
| 78 | Cleaning the old roof treat ment from thr roof of bedg including taking down and removing as per specifed and directed by Engineer in Charge. |
| 79 | Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 all as per specifed and directed by Engineer in Charge. |
| 80 | Rendering 10mm thick on fair faces of concrete surfaces in cement mortar 1:4, mixed with liquid water proofing compound finished even and smooth without using extra cement . (Liquid water proofing compound to be measured paid separately) complete all as per specifed and directed by Engineer in Charge. |
| 81 | M&L for roof treatment with polymeric water proofing membrane consisting of following complete all as specified and directed:- (a) Applying bituminous grade 85/25 primer conforming to IS 702- 1988 @ 1.20 Kgs/Sqm (b) APP modifiedd bitumenous membrane minimum weight 3 Kg/Sqm and minimum 3 mm thick reinforced with polyester non wove fabric( wt not less than 150 gms/Sqm) laid on primed surface by heat process, over laps of 100 mm shall be sealed/fused by flame torch application as per manufacturer instruction. (c) applying two coats of bitumen based @ 0.20 Kgs/Sqm aluminium painting on water proofing treatment all as per specifed and directed by Engineer in Charge. |
| 82 | Alluminium painting on water proofing treatmentas appoxy basin paint all as per specifed and directed by Engineer in Charge. |
| 83 | Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc, all as per specifed and directed by Engineer in Charge. |
| 84 | M&L for 15mm thick rendering in CM 1:4 with on fair surfaces of walls finished even and smooth without using extra cement complete all as per specifed and directed by Engineer in Charge. |
| 85 | M&L PCC 1:2:4 Type B-1 as in benching etc. all as per specifed and directed by Engineer in Charge. |
| 86 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises, all as per specifed and directed by Engineer in Charge. |
| 87 | S&F vitrified ceramic tiles dark/light shade digital tiles/(double charged), 10mm thick (square/ rectanglar) polished , exceeding0.18 sqm of each tiles not exceeding 0.38 sqm, in floors etc. laid over 15mm thick screed bed 1:6 , set and jointed in neat cement slurry and pointed in white/coloured cement to match complete all as per specifed and directed by Engineer in Charge. Make : Somany,/Johnson/Kajariya |
| 88 | M&L Glazed ceramic tiles (coloured) in vertical surfaces 600x300x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to matchover 10mm thick rendering in cement mortar 1:3 complete all as per specifed and directed by Engineer in Charge. |
| 89 | M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as per specifed and directed by Engineer in Charge. |
| 90 | M&L PCC 40 mm thick 1:2:4 of type B0 using 12.5mm graded stone aggregate as in base of floors complete all as per specifed and directed by Engineer in Charge. |
| 91 | S&F Vitreous china wash down water closet pan (pedestal pattern) white (excluding fixing bolts flushing cistern and flush pipe ). and trap including connection to drain (or out going pipe) and to flushing pipe anti sphonage pipe etc complete including flush pipes and all joints add if fixed in repairs and all as per specifed and directed by Engineer in Charge..Make:Cera/Periware/Hindware |
| 92 | S&F Plastic water closet seat cover coloured/white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device all as per specifed and directed by Engineer in Charge. |
| 93 | S&F Vitreous wash basin 500x450mm all as per specifed and directed by Engineer in Charge. |
| 94 | S&F Vitreous china squatting pan Orissa pattern size 580x440 mm white with P or S trap front or back inlet with integral foot rests (excluding flushing cistern and flush pipe ) complete including provision of lime concrete bedding add if fixed in repair all as per specifed and directed by Engineer in Charge. |
| 95 | S&F 10 Litres capacity PVC valveless syphonic action type flushing cistern low level, white with inlet ball valve float and handle including brackets connection to pipes and fixing of lever if any joint between flushing pipe and socket of WC pan pre-made all as per specifed and directed by Engineer in Charge. Make : Parry ware/Slimline/ Cera |
| 96 | S&F 15mm dia fancy type chromium plated bib taps cast copper alloy with crutch or butterfly handle, scresed down screwed for iron pipe or for brass ferrule and fixed both ends for iron pipe |
| 97 | S&F PVC connection of 15 mm bore 600 mm long with brass coupling on both ends of superior quality all as specified.PTMT nuts fixed as in repair. All as per specifed and directed by Engineer in Charge. |
| 98 | Supplying and laying of 16 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as per specifed and directed by Engineer in Charge. |
| 99 | Supplying and laying of 25 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as per specifed and directed by Engineer in Charge. |
| 100 | Supplying and laying of 32 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as per specifed and directed by Engineer in Charge. |
| 101 | S&F for in repair three layer rotational moulded polyethylene water storage tank cylindrical hoisted & fixed in position incl dismantiling water tank complete all as per specifed and directed by Engineer in Charge. capacity 1000ltrs. |
| 102 | S&F in repair 20 mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod and high density Plastic ball Screwed for iron pipe and fixed (Minimum weight -210 gms. all as per specifed and directed by Engineer in Charge.Make Prayag/Polytuff |
| 103 | S&F in repair 32 mm Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed. all as per specifed and directed by Engineer in Charge. MakePrayag/Polytuff |
| 104 | S&F in repair 15 mm dia Pillar tap cast copper alloy chromium plated fancy type with capstan head and cup screwed down screwed for G I pipe or for brass ferrule all as per specifed and directed by Engineer in Charge. |
| 105 | S&F in repairs 32 mm dia Waste coupling of PTMT all as per specifed and directed by Engineer in Charge. (half or full threaded) . (Minimum weight 32mm 45gms/40mm-60 gms) |
| 106 | S&F in repairs 32mm dia PVC waste pipe approx 900mm longfor sink/WHB complete all as per specifed and directed by Engineer in Charge. |
| 107 | S&F in repair health feucet to EWC CP brass with minimum 1500mm long CP flexible pipe connection etc, complete all as approved Make : Parryware Cat No T9940A1 or equvailent . All as per specifed and directed by Engineer in Charge. |
| 108 | S&F in repairs 15mm dia CP two way tap consisting angle valve to control water suitable for jet cleaner all as per specifed and directed by Engineer in Charge. Make:Jaguar /ESS-ESS/Prayag |
| 109 | S&F 600 mmx450x5 mm bevelled edge mirror of selected quality glass mounted on 6.0 mm thick AC building board or commercial plywood and fixed wooden plug with chromium coated brassscrews and cup washers. All as per specifed and directed by Engineer in Charge. |
| 110 | Complete removal of existing treatment by scrapping withTrucare Wall Sander:t etc. by skilled labour. All as per specifed and directed by Engineer in Charge. |
| 111 | Painting on two coat plastic emulsion paint over a coat of primer. All as per specifed and directed by Engineer in Charge. |
| 112 | M&L for two coat of paint over a coat of primer over old existingsurface by Apex altima paint. All as per specifed and directed by Engineer in Charge. |
| 113 | Excavation in trenches not exc 1.5 mtr wide & not exc.1.5mtr depth for foundation, manholes etc and getting out soft/loose soil complete all as per specifed and directed by Engineer in Charge. |
| 114 | M & L PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundation or mass concrete etc completeall as per specifed and directed by Engineer in Charge. |
| 115 | M&L for Modular fly ash brick work built in cm 1:4 all as per specifed and directed by Engineer in Charge. |
| 116 | Returning filling in cluding spreading levelling watering and well ramming in layers not exc 25cm in hard dense soil. |
| 117 | Removing excavated material exc. 250 m but n exc. 500 mand depositing where all as per specifed and directed by Engineer in Charge. |
| 118 | M&L 15mm thick rendering in (CM) 1:4 on fair surfaces ofbrick walls finished even and smooth without using extra cement. all as per specifed and directed by Engineer in Charge. |
| 119 | M&L preparation of new plastered surfaces of walls andapplying two coats of cement base paint over one coat of primer complete all as per specifed and directed by Engineer in Charge. |
| 120 | M&L TMT 10mm dia and over cut to length, bent to shape required incl. cranking, bending and incl. mild steel wire (annealed) not less than 0.9mm dia or securing with clips. All as per specifed and directed by Engineer in Charge. |
| 121 | S&F M.S framed work such as gate with hold fast handleand locking arrangement etc. all as per specifed and directed by Engineer in Charge. |
| 122 | S&F Sign Board with writing work and glow sign light of 4Nos 20W each including Aluminium frame all as per specifed and directed by Engineer in Charge. |
| 123 | M&L for preparation of new steel and iron surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer all as per specifed and directed by Engineer in Charge. |
| 124 | Taking Down the wooden chowkhat including shutter Exc. 1.50 SQM N. Exc. 4.00 SQM all as per specifed and directed by Engineer in Charge. |
| 125 | M&L 2nd class hard wood as in wooden frame all as per specifed and directed by Engineer in Charge. |
| 126 | Supply and fixe 40 mm Thick flush Shutter as in Door Solid core Construction with block Board plywood Face panels commercial type all as per specifed and directed by Engineer in Charge. |
| 127 | Cutting Holes in Brick Wall in cement Mortar for inserting Hold fast and making good in cement mortar 1:3 Exc. Half brick N.exc one brickall as per specifed and directed by Engineer in Charge. |
| 128 | Material and Labour PCC 1.2.4 Type B-1 as in bed Block all as per specifed and directed by Engineer in Charge. |
| 129 | Supply and Fixe Hold fast as in M.S. for frame make to shape all as per specifed and directed by Engineer in Charge. |
| 130 | Supply and Fixe Mild steel hinge 150mm Size medium weight (SS.) all as per specifed and directed by Engineer in Charge. |
| 131 | Supply and Fixe Mild Steel hinge 75mm Size medium weight (SS.) all as per specifed and directed by Engineer in Charge. |
| 132 | Supply and Fixe 2nd class HW as in cleat/stopper for door /windows medium weight (SS.) all as per specifed and directed by Engineer in Charge. |
| 133 | Supply and Fixe Alluminium 300 mm size sliding bolt including hooks complete medium weight (SS.) all as per specifed and directed by Engineer in Charge. |
| 134 | Supply and Fixe Alluminium 200 mm size toner bolt all as per specifed and directed by Engineer in Charge. |
| 135 | Supply and Fixe (S.S.) Handle 150 mm size all as per specifed and directed by Engineer in Charge. |
| 136 | Material and Labour for two coat paint over a coat of primer over old prepared wooden surface all as per specifed and directed by Engineer in Charge. |
| 137 | Material and Labour for two coat paint over a coat of primer over old prepare surface all as per specifed and directed by Engineer in Charge. |
| 138 | Site Clearance |
| 139 | Excavation over area not exceeding 30 cm in depth and averaging 15 cm deep in soft loose soil. Including removal of surface soil, Grass Plant etc. cleaning complete all as specified and as per direction of Engineer – in - Charge |
| 140 | Excavation Over Area In Soft Loose Soil N.Exc.1.50m Depth. complete all as specified and as per direction of Engineer – in - Charge |
| 141 | Excavation in soft/loose soil over areas and in trenches up to 1.50 m depth and 1.50 m width (not exceeding), complete all as specified and as per direction of Engineer – in - Charge |
| 142 | Excavation do all as in item 3 above but exceeding 1.50 Mts Depth. complete all as specified and as per direction of Engineer – in – Charge. |
| 143 | Returning filling in layers not exceeding 15 cm thickness, including watering and ramming,complete all as specified and as per direction of Engineer – in - Charge |
| 144 | Removing excavated soil to a distance not exceeding 500 m, complete all as specified and as per direction of Engineer – in - Charge |
| 145 | Sewage work |
| 146 | Laying PCC 1:4:8 type D-2 As in foundation & Bedding/ Haunching of Sewer Line. complete all as specified and as per direction of Engineer – in - Charge |
| 147 | Material and Labour Brick Work in Sub Class ‘B’Bricks in cement Mortar 1:4. Complete all as specified and as per direction of Engineer – in - Charge |
| 148 | Supplying and laying PCC 1:3:6 (Type C-1) in benching and coping including finishing smoothcomplete all as specified and as per direction of Engineer – in - Charge |
| 149 | Supplying and fixing formwork (centering & shuttering) for slabs including supports andremoval complete all as specified and as per direction of Engineer – in – Charge. |
| 150 | Supplying and fixing formwork (centering and shuttering) to edges of slabs not exceeding 100 mm in width including all supports, struts, staging, removal after completion and making good thesurfaces complete all as specified and as per direction of Engineer – in - Charge |
| 151 | Supplying and fixing reinforcement steel (10 mm dia bars), cut to length, bent to shape and bound with 0.90mm dia annealed binding wire complete all as specified and as per direction of Engineer – in - Charge |
| 152 | Supplying and fixing 15 mm thick cement plaster in CM 1:4 finished smooth with extra cementincluding curing complete all as specified and as per direction of Engineer – in - Charge |
| 153 | Supplying and laying PVC sewer pipe 150 mm diaincluding jointing, cutting and testing complete all as specified and as per direction of Engineer – in – Charge. |
| 154 | Supplying and laying concrete in benching andaround pipe including finishing complete all as specified and as per direction of Engineer – in – Charge. |
| 155 | Returning, filling and compacting excavated soil in trenches including watering and rammingcomplete all as specified and as per direction of Engineer – in - Charge |
| 156 | Removal and disposal of surplus excavated soilwithin 50 m lead. complete all as specified and as per direction of Engineer – in - Charge |
| 157 | Supplying and laying RCC 1:1.5:3 (M-20) in slab for manhole including centering, shuttering and curingcomplete all as specified and as per direction of Engineer – in – Charge. |
| 158 | Supplying and fixing precast RCC 1:1.5:3 manholecover set in CM 1:4 with 20 mm aggregate including finishing complete all as specified and as per direction of Engineer – in – Charge. |
| 159 | Road path way |
| 160 | Rolling and compaction of prepared surface using power roller of 10–15 tonne capacity including watering, dressing and achievingrequired density complete all as specified and as per direction of Engineer – in – Charge. |
| 161 | Providing, laying and compacting 150 mm thick stone soling using hand packed broken boulders including filling of interstices withsmaller stones, watering and rolling complete all as specified and as per direction of Engineer – in – Charge. |
| 162 | Removal of excavated material not exceeding 50 metres lead and depositing at a level not exceeding 1.5 metres above the starting point including loading, unloading and stackingcomplete all as specified and as per direction of Engineer – in – Charge. |
| 163 | Supplying and laying 80 mm thick factory-made chamfered edge cement concrete interlocking paver blocks of M-30 grade, of approved colour, design and pattern, over 50 mm thick compacted coarse sand bed includingcompaction, joint filling and finishing complete all as specified and as per direction of Engineer – in – Charge. |
| 164 | Supplying and laying cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded aggregate) in benching and similar works including mixing,placing, compacting and curing complete all as specified and as per direction of Engineer – in – Charge. |
| 165 | Supplying, laying, jointing and testing of galvanized iron (GI) pipes of 40 mm nominal bore, medium class, including all necessary fittings such as bends, tees, sockets, unions, nipples, clamps, cutting, threading, fixing in position, and testing forleakage complete all as specified and as per direction of Engineer – in – Charge. |
| 166 | Boundary wall and gate |
| 167 | Supplying and laying PCC 1:4:8 with 40 mm graded stone aggregate in foundation including mixing, placing, compactingand curing complete all as specified and as per direction of Engineer – in – Charge. |
| 168 | Supplying and laying brick masonry in cement mortar 1:4 using sub-class bricks in wall including raking of joints andcuring complete all as specified and as per direction of Engineer – in – Charge. |
| 169 | Supplying and laying 15 mm thick cement plaster in CM1:4 on wall surfaces finished fair and smooth including curing complete all as specified and as per direction of Engineer – in – Charge. |
| 170 | Supplying and laying PCC in coping/bed block includingmixing, placing, compacting and finishing complete all as specified and as per direction of Engineer – in – Charge. |
| 171 | Supplying and fixing mild steel posts for fencing includingembedding in concrete, alignment and fixing complete all as specified and as per direction of Engineer – in – Charge. |
| 172 | Preparing steel surfaces and applying one coat of primerand two coats of paint on steel surfaces complete all as specified and as per direction of Engineer – in – Charge. |
| 173 | Preparing wall surfaces and applying two coats of exteriorpaint over suitable base completes all as specified and as per direction of Engineer – in – Charge. |
| 174 | Returning, filling and compacting excavated soil includingwatering and ramming complete all as specified and as per direction of Engineer – in – Charge. |
| 175 | Removal and disposal of surplus excavated soil includingloading, unloading and stacking complete all as specified and as per direction of Engineer – in – Charge. |
| 176 | Supplying and fixing galvanised steel barbed wire fencing with two strands of 2.24 mm dia barbed wire with 2 mm dia barbs at 75 mm spacing including straining, fixing to posts,tying at crossings and all accessories complete all as specified and as per direction of Engineer – in – Charge. |
| 177 | Supplying, fabricating and fixing mild steel gate includingcutting, welding, grinding, fixing in position and painting complete all as specified and as per direction of Engineer – in – Charge. |
| 178 | Supplying and fixing illuminated sign board over gate of size20 ft × 4 ft including LED lighting arrangement, frame, wiring and fixing complete all as specified and as per direction of Engineer – in – Charge. |
| 179 | Drain work |
| 180 | Supplying and laying PCC 1:4:8 (Type D-2)in base of foundation including mixing, placing, compacting and curing complete all as specified and as per direction of Engineer – in – Charge. |
| 181 | Supplying and laying brick masonry in cement mortar 1:4 using sub-class B bricksincluding raking of joints and curing complete all as specified and as per direction of Engineer – in – Charge. |
| 182 | Supplying and laying PCC 1:3:6 (Type C-1)in coping and benching finished fair and smooth complete all as specified and as per direction of Engineer – in – Charge. |
| 183 | Supplying and applying 15 mm thick cement plaster in CM 1:4 on wall surfacesfinished smooth including curing complete all as specified and as per direction of Engineer – in – Charge. |
| 184 | Supplying and fixing precast cement concrete 1:2:4 cover slabs for drain set in cement mortar 1:4 including finishingcomplete all as specified and as per direction of Engineer – in – Charge. |
| 185 | Supplying and laying TMT reinforcement steel for cover slab including cutting, bendingand binding with binding wire complete all as specified and as per direction of Engineer – in – Charge. |
| 186 | Removal and disposal of excavated soil not exceeding 50 metres lead including loading,unloading and stacking complete all as specified and as per direction of Engineer – in – Charge. |
| 187 | Parking |
| 188 | Excavation in trenches n.exc. 1.50 m deep and not exceeding 1.5 m wide in soft loose soil all as per direction of Engineer inCharge. |
| 189 | Material and labour P.C.C. 1:5:10 as infoundation and sub base of floor as per direction of Engineer in Charge. |
| 190 | Material and labour of sub class ‘B’ bricks incement mortar 1:4 as in wall all as per direction of Engineer in Charge. |
| 191 | Material and labour in cement mortar rendering 15 mm thick in CM 1:4 finished fair and smooth all as per direction ofEngineer in Charge. |
| 192 | Returning filling the soil in layers 25 cm thick, watering, ramming, levelling all as per direction of Engineer in Charge. |
| 193 | Removing the soil to a distance of 50 meterall as per direction of Engg in Charge |
| 194 | Use and waste the form work of column and column footing as per direction of Engineerin Charge |
| 195 | Material and labour R.C.C. M-25 as in column footing and column all as per direction of Engineer in Charge. |
| 196 | Supply and fix mild steel reinforcement TMT bar 10# and over, cut to length, bent toshape all as directed |
| 197 | Do – but 8 mm Ø as in stirrups all as per direction of Engineer in Charge |
| 198 | Material and labour 60 mm thick interlocking paver block M-35 as in floor on Ganga sand 50 mm cushion. |
| 199 | Supply only Ganga sand as for floor as perdirection of EIC. |
| 200 | Material and labour of PCC 1:2:4 type B1 as in bed block and coping etc all as perdirection of Engineer in Charge. |
| 201 | Supply and mild steel work as in hold fast / anchor bolt as per direction of Engineer in Charge. |
| 202 | Supply and fix mild steel tube as in structure of truss and stanchion as per specification & direction of Engineer in Charge. |
| 203 | Supply and fix 10 mm thick double layer poly carbonate sheet as per direction ofEngineer in Charge. |
| 204 | Material and labour for two coat painting over a coat of primer over newly prepared steel surface all as per direction of Engineerin Charge. |
| 205 | Material and labour for painting two coat Apex Ultima on a coat of primer over newly prepared surface plastered all as perdirection of Engineer in Charge. |
| 206 | External electrification |
| 207 | Supply, design, installation, testing, and commissioning of factory-made, powder-coated, CPRI-approved outdoor LT Feeder Pillar Panel with canopy, dust- and vermin-proof, made of 3 mm thick CRCA steel sheet of suitable size with 50x50x6 mm angle iron frame, powder-coated over red-oxide primer, including grouting in PCC M10 with 20 mm graded stone aggregate 45 cm above ground, complete with internal wiring using suitably sized PVC-insulated, single-core FRLSH copper cables, duly numbered with circuit tags, hinged double-door shutters (front and rear), cubical-type locking arrangement, and slanted roof, including dismantling of existing LT panel and proper connection of incoming and outgoing cables, complete as per SSR Part I, Clause 19.21, and as directed by the Engineer-in-Charge. INCOMING:MCCB, AC 415 V, 125 A, 4-pole, 35/36 kA breaking capacity, fixed TM range, IS13947-II compliant, with busbar connections - 1 No.OUTGOING:MCCB, AC 415 V, 63 A, 4-pole, 16 kA breaking capacity, adjustable type, IS13947-II compliant, with busbar connections (Make: C&S / Havells / Indoasian / L&T / Legrand) - 4 Nos.Aluminium busbar, 250 A capacity, with heat-shrinkable sleeves, mounted on DMC post insulators, 1100 V grade - 4 Nos.Digital voltmeter, 100x100 mm, 0-500 V, flush-mounted with selector switch (Make: AE / L&T / C&S) - 1 set.Digital ammeter, 100x100 mm, flush-mounted, with suitable CTs and selector switch (Make: AE / L&T / C&S) - 1 set.Phase indicator (RYB) LED lamps - 1 set. |
| 208 | Supply, laying, fixing, jointing, testing, and commissioning of LT underground electric power cable, cross-linked polyethylene (XLPE) insulated, galvanised steel strip or wire armoured/PVC insulated, ISI 7098 marked, aluminium conductor, multi-stranded, heavy-duty, 1100 V grade complete, laid in trenches, under floors, fixed naked on walls, on poles, in ducts, or in GI pipes, as specified and directed by the Engineer-in-Charge of following size :- 50 Sqmm cross sectional area, 3½ Core. 16 Sqmm cross sectional area, 4 Core. |
| 209 | Material and labour for earthing complete with galvanised mild steel earth plate electrode 600 mm × 600 mm × 6mm thick, buried vertically in ground to a depth not less than 2.25 m below ground level, with top edge of plate not less than 1.5 m below normal ground level. Plate to be packed on all sides with charcoal dust mixed with salt to a thickness of 150 mm. GI strip 32×6 mm to be bolted/riveted to plate and connected to equipment, encased in 40 mm dia GI light grade pipe from plate to equipment. Provide 20 mm dia GI pipe as water pipe with test point, GI funnel with wire mesh, PCC 1:2:4 (using 20 mm graded stone) for pit chamber, RCC pit cover 50 mm thick precast 1:2:4 reinforced with MS bars 6 mm dia @100 mm c/c both ways and 10 mm dia lifting handles. Includes excavation, earth work, laying GI pipe in floor/wall and testing on completion. If desired earth resistance is not achieved, earthing to be redone at no extra cost, complete as specified and directed. |
| 210 | Internal electrification |
| 211 | Taking down carefully copper/ Aluminium main wiring from existing concealed PVC conduit complete and making good disturbed surfaces of wall floor etc and matching with original colour of wall as specified |
| 212 | M&L for point wiring complete for one light/fan/exhaust fan point controlled by one, one way 6 Amp switch with PVC (FRLSH) insulated sheathed multistranded copper conductors of size 1.50 sqmm nominal cross sectional area single core drawn in and including minimum 20mm dia 'medium grade' PVC concealed conduits ISI marked and fittings, including anadised pressed steel concealed terminal switch boxes not less than 1.20 mm thick of reqd size factory made duly painted inside and outside with one coat red oxide primer, 3mm thick plastic laminated bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers complete including 1.50 sqmm nominal cross sectional area PVC (FRLSH) insulated sheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories including cutting chases for concealed piping and making good disturbed surface to match the existing surface compleate all as specified and directed. |
| 213 | M&L for point wiring complete for one light/fan/exhaust fan point controlled by one, two way 6 Amp switch with PVC (FRLSH) insulated sheathed multistranded copper conductors of size 1.50 sqmm nominal cross sectional area single core drawn in and including minimum 20mm dia 'medium grade' PVC concealed conduits ISI marked and fittings, including anadised pressed steel concealed terminal switch boxes not less than 1.20 mm thick of reqd size factory made duly painted inside and outside with one coat red oxide primer, 3mm thick plastic laminated bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers complete including 1.50 sqmm nominal cross sectional area PVC (FRLSH) insulated sheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories including cutting chases for concealed piping and making good disturbed surface to match the existing surface compleate all as specified and directed. |
| 214 | All as per srl item No 1 above but for for 5 pin 6 Amps socket outlet independent board complete all as specified and directed. |
| 215 | All as per srl item No 1(a) above but for for 3 pin 6 Amps socket outlet on the same board with other switch complete all as specified and directed. |
| 216 | All as per srl item No 1 above but for for 6 pin 16 Amps socket outlet point on independent board with cables of size 2.50 Sqmm and green colour earth cable of size 2.50 Sqmm complete all as specified and directed. |
| 217 | S&F switch piano flush type onw way 6 Amps SP 240 volts complete all as specified and directed. |
| 218 | S&F switch piano flush type onw way 16 Amps SP 240 volts complete all as specified and directed. |
| 219 | S&F socket outlet 2 in 1, 3 pin 6 Amps flush type 240 volts complete all as specified and directed. |
| 220 | S&F socket outlet 2 in 1, 6 pin, 6 and 16 Amps flush type 230 volts complete all as specified and directed. |
| 221 | S&F switch piano flush type Two way 16 Amps SP 240 volts complete all as specified and directed. |
| 222 | S&F ceiling rose 65 x 50mm three terminals complete all as specified and directed. |
| 223 | S&F fan regulator, electronic stepped type 5 stage speed regulation, ISI marked complete all as specified and directed. |
| 224 | S&F lamp holder/ batten holder/ angle holder insulated body with bakelite back plate suitable for fittings complete all as specified and directed. |
| 225 | S&F Lamp with LED Lamp 9 watt, 6500 K, 230 volts B-22 Base complete all as specified and directed. Make - Havells/ Philips/ Bajaj |
| 226 | S&F sheeet metal enclosure MCB distribution board, double door with IP-43 protection Triple pole and neutral 240 volts, 4 way, including suitable size copper bus bar and neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces complete all as specified and directed. |
| 227 | S&F sheeet metal enclosure MCB distribution board, double door with IP-43 protection single pole and neutral 240 volts, 12 way, including suitable size copper bus bar and neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces complete all as specified and directed. |
| 228 | S&F MCB TPN 415 volts, 'C' curv of rating 63 Amps with rupturing capacity 10 kA including providing thimble for outgoing cables complete all as specified and directed. |
| 229 | S&F MCB Single pole 240 volts, 'C' curv of rating 6 to 32 Amps with rupturing capacity 10 kA including providing thimble for outgoing cables complete all as specified and directed. |
| 230 | S&F MCB SPN 240 volts, 'C' curv of rating 6 to 32 Amps with rupturing capacity 10 kA including providing thimble for outgoing cables complete all as specified and directed. |
| 231 | Supply and fixing BLDC 5 star ceiling fan 1200 mm sweep with remote suitable to work on single phase AC 230 Volts 50 Hz complete with connecting electrically to ceiling rose or connector block using PVC insulated and over all shethed 3 core cable of size 0.75 sqmm with flexible copper cable all as required at site complete all as specifed and directed. |
| 232 | Supply and fixing air Ventillating fan 300 mm dia metalic body heavy duty single phase 230 Volts 2200 RPM including fixing and connecting the fan with 3 core PVC insulated and over all sheathed flexible copper conductor cable from ceiling rose / PVC connector block to exhaust fan including making suitable hole in wall and make good disturbed surface of wall including louvers of suitable size and fastener, nut bolts etc all as required at site complete all as specifed and directed. |
| 233 | S&F sub main wiring with two single core PVC insulted (FRLS) unsheathed multistranded copper conductor of size 6 sqmm nominal cross sectional area and one run of 6 sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continious earth wire drawn in and including not less than 20 mm dia 'medium grade' PVC concealed conduits (ISI marked) and fitting including cutting chases to walls from laying conduit and making good the disturbed wall surface to match with existing specification complete all as specified and directed. |
| 234 | M&L earthing complete with galvanised mild steel earth plate electrode 60 x 60 cm x 6mm thick, burried directly in ground vertically to a depth not less than 2.25 mtr below ground level, with top edge of earth plate not less than 1.5 m below normal ground level, connected to galvanised earth lead wire 4 mm dia by means of bolts, check nuts and washers of galvanised iron or steel earth plate shall be packed on all side with charcoal dust mixed with salt to a thickness of 150 mm, galvanised earth lead wire 4 mm dia bolted or riveted to earth plate on one end and connected to equipments on another end. GI earth wire encased in and including 15 mm dia GI light grade pipe from upper end of earth plate upto equipments, 20 mm dia bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, test point, GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in pit chamber and RCC pit over 50 mm thick precast RCC 1:2:4 type B1, duly reinforced with MS round bars 6 mm dia @ 100 c/c both ways with 10 mm dia MS round bar as in lifted handles, excavation, earth work including laying the GI pipe concealed in floor/ wall all as described in electric plate of MES SSR part I complete all as specified and directed and testing on completion. Note:- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. |
| 235 | M&L for point wiring complete for one light/fan/exhaust fan point controlled by one, one way 6 Amp switch with PVC (FRLSH) insulated sheathed multistranded copper conductors of size 1.50 sqmm nominal cross sectional area single core drawn in and including minimum 20mm dia 'medium grade' PVC concealed conduits ISI marked and fittings, including anadised pressed steel concealed terminal switch boxes not less than 1.20 mm thick of reqd size factory made duly painted inside and outside with one coat red oxide primer, 3mm thick plastic laminated bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers complete including 1.50 sqmm nominal cross sectional area PVC (FRLSH) insulated sheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories including cutting chases for concealed piping and making good disturbed surface to match the existing surface compleate all as specified and directed. |
| 236 | M&L for point wiring complete for one light/fan/exhaust fan point controlled by one, two way 6 Amp switch with PVC (FRLSH) insulated sheathed multistranded copper conductors of size 1.50 sqmm nominal cross sectional area single core drawn in and including minimum 20mm dia 'medium grade' PVC concealed conduits ISI marked and fittings, including anadised pressed steel concealed terminal switch boxes not less than 1.20 mm thick of reqd size factory made duly painted inside and outside with one coat red oxide primer, 3mm thick plastic laminated bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers complete including 1.50 sqmm nominal cross sectional area PVC (FRLSH) insulated sheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories including cutting chases for concealed piping and making good disturbed surface to match the existing surface compleate all as specified and directed. |
| 237 | All as per srl item No 1 above but for for 5 pin 6 Amps socket outlet independent board complete all as specified and directed. |
| 238 | All as per srl item No 1(a) above but for for 3 pin 6 Amps socket outlet on the same board with other switch complete all as specified and directed. |
| 239 | All as per srl item No 1 above but for for 6 pin 16 Amps socket outlet point on independent board with cables of size 2.50 Sqmm and green colour earth cable of size 2.50 Sqmm complete all as specified and directed. |
| 240 | S&F switch piano flush type one way 6 Amps SP 240 volts complete all as specified and directed. |
| 241 | S&F switch piano flush type one way 16 Amps SP 240 volts complete all as specified and directed. |
| 242 | S&F socket outlet 2 in 1, 3 pin 6 Amps flush type 240 volts complete all as specified and directed. |
| 243 | S&F socket outlet 2 in 1, 6 pin, 6 and 16 Amps flush type 230 volts complete all as specified and directed. |
| 244 | S&F switch piano flush type Two way 6 Amps SP 240 volts complete all as specified and directed. |
| 245 | S&F ceiling rose 65 x 50mm three terminals complete all as specified and directed. |
| 246 | S&F fan regulator, electronic stepped type 5 stage speed regulation, ISI marked complete all as specified and directed. |
| 247 | S&F lamp holder/ batten holder/ angle holder insulated body with bakelite back plate suitable for fittings complete all as specified and directed. |
| 248 | S&F light fitting with energy saving decorative LED batten 20 watt (4 Feet), 230 volts, energy efficient tube light fitting extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronin driver complete with all accessories prewired and including making connections with 3 core twisted flexible copper cable of size 23/.0076 from ceiling rose/ PPVC connector to light fittings complete all as specified and directed. |
| 249 | S&F Lamp with LED Lamp 9 watt, 6500 K, 230 volts B-22 Base complete all as specified and directed. Make - Havells/ Philips/ Bajaj |
| 250 | S&F sheeet metal enclosure MCB distribution board, double door with IP-43 protection Triple pole and neutral 240 volts, 4 way, including suitable size copper bus bar and neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces complete all as specified and directed. |
| 251 | S&F sheeet metal enclosure MCB distribution board, double door with IP-43 protection single pole and neutral 240 volts, 12 way, including suitable size copper bus bar and neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces complete all as specified and directed. |
| 252 | S&F MCB TPN 415 volts, 'C' curv of rating 63 Amps with rupturing capacity 10 kA including providing thimble for outgoing cables complete all as specified and directed. |
| 253 | S&F MCB Single pole 240 volts, 'C' curv of rating 6 to 32 Amps with rupturing capacity 10 kA including providing thimble for outgoing cables complete all as specified and directed. |
| 254 | S&F MCB SPN 240 volts, 'C' curv of rating 6 to 32 Amps with rupturing capacity 10 kA including providing thimble for outgoing cables complete all as specified and directed. |
| 255 | Supply and fixing BLDC 5 star ceiling fan 1200 mm sweep with remote suitable to work on single phase AC 230 Volts 50 Hz complete with connecting electrically to ceiling rose or connector block using PVC insulated and over all shethed 3 core cable of size 0.75 sqmm with flexible copper cable all as required at site complete all as specifed and directed. |
| 256 | Supply and fixing air Ventillating fan 300 mm dia metalic body heavy duty single phase 230 Volts 2200 RPM including fixing and connecting the fan with 3 core PVC insulated and over all sheathed flexible copper conductor cable from ceiling rose / PVC connector block to exhaust fan including making suitable hole in wall and make good disturbed surface of wall including louvers of suitable size and fastener, nut bolts etc all as required at site complete all as specifed and directed. |
| 257 | S&F sub main wiring with two single core PVC insulted (FRLS) unsheathed multistranded copper conductor of size 6 sqmm nominal cross sectional area and one run of 6 sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continious earth wire drawn in and including not less than 20 mm dia 'medium grade' PVC concealed conduits (ISI marked) and fitting including cutting chases to walls from laying conduit and making good the disturbed wall surface to match with existing specification complete all as specified and directed. |
| 258 | M&L earthing complete with galvanised mild steel earth plate electrode 60 x 60 cm x 6mm thick, burried directly in ground vertically to a depth not less than 2.25 mtr below ground level, with top edge of earth plate not less than 1.5 m below normal ground level, connected to galvanised earth lead wire 4 mm dia by means of bolts, check nuts and washers of galvanised iron or steel earth plate shall be packed on all side with charcoal dust mixed with salt to a thickness of 150 mm, galvanised earth lead wire 4 mm dia bolted or riveted to earth plate on one end and connected to equipments on another end. GI earth wire encased in and including 15 mm dia GI light grade pipe from upper end of earth plate upto equipments, 20 mm dia bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, test point, GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in pit chamber and RCC pit over 50 mm thick precast RCC 1:2:4 type B1, duly reinforced with MS round bars 6 mm dia @ 100 c/c both ways with 10 mm dia MS round bar as in lifted handles, excavation, earth work including laying the GI pipe concealed in floor/ wall all as described in electric plate of MES SSR part I complete all as specified and directed and testing on completion. Note:- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. |
| 259 | Demolition of cement concrete as if floor, in any ratio including removal within 50 mdistance, as per direction of Engineer In-Charge |
| 260 | Dismantling of brickwork built in cement mortar all as per direction of Engineer In-Charge |
| 261 | Demolition to old RCC work as in column and footing etc. as per specification and direction of Engineer In-Charge |
| 262 | Supply and laying CPVC 50 mm DIA medium weight water supply pipe including all fittings and jointing all as specified and directed by Engineer in charge. |
| 263 | Supply and fixe CPVC 50 mm DIA stop cock all as specified and directed by Engineer in Charge. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail