Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Demolition of brickwork masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all specified and directed by E/I |
| 2 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out of Soft/loose soil complete all specified and directed. |
| 3 | Returning, filling, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick of Soft/loose soil complete all specified and directed. |
| 4 | M&L for anti-termite treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all specified and directed by E/I |
| 5 | M&L for anti-termite treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all specified and directed by E/I |
| 6 | M&L for anti-termite treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all specified and directed by E/I |
| 7 | M&L for anti-termite treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all specified and directed by E/I |
| 8 | M & L Cement concrete in foundations, filling and mass concrete Type D2 1:4:8 (40 mm graded aggregate) |
| 9 | M&L for RCC work with cement approved coarse sand and 20mm graded aggregates approved stone ballas confirming M-20 mixed in foundation / footing, plinth beam etc. excluding steel reinforcement and formwork complete all specified and directed. |
| 10 | M&L for RCC work with cement approved coarse sand and 20mm graded aggregates approved stone ballas confirming M-20 mixed in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves excluding steel reinforcement and formwork complete all specified and directed. |
| 11 | M&L for RCC work with cement approved coarse sand and 20mm graded aggregates approved stone ballas confirming M-20 mixed in Beams, cantilevers, bressummers, lintels over 1.5m span excluding steel reinforcement and formwork complete all specified and directed. |
| 12 | M&L for RCC work with cement approved coarse sand and 20mm graded aggregates approved stone ballas confirming M-20 mixed in Columns, pillars, piers, posts and struts excluding steel reinforcement and formwork complete all specified and directed. |
| 13 | M&L for RCC work with cement approved coarse sand and 20mm graded aggregates approved stone ballas confirming M-20 mixed in Chajjas excluding steel reinforcement and formwork complete all specified and directed. |
| 14 | M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in reinforcement complete all specified and directed |
| 15 | M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter finished surface fair and even complete all specified and directed. |
| 16 | M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) finished surface fair and even complete all specified and directed. |
| 17 | M&L Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping, and similar work all exceeding 20cm wide (Where RCC/PCC band in walls, spanning and opening, the formwork soffit only shall be paid for under item 07010) finished surface fair and even complete all specified and directed. |
| 18 | M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. finished surface fair and even complete all specified and directed. |
| 19 | M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions etc. finished surface fair and even complete all specified and directed. |
| 20 | M&L for Formwork to Formwork to chullah hoods, chajjas, troughs and similar items including edges complete all specified and directed. |
| 21 | M&L for Brickwork with subclass ‘A’ bricks, straight or curved on plan exc 6m mean radius built in cement motar 1:6 complete all specified and directed. |
| 22 | M&L for Brickwork with subclass ‘A’ bricks, straight or curved on plan to any radius built in half brick thick walls built in cement motar 1:4 complete all specified and directed. |
| 23 | M&L for 12mm thick cement plastring in 1:6 cement motar on fair faces of brick work or concrete surface finished even and smooth without using extra cement on surface complete all specified and directed. |
| 24 | M&L for Screed bed or bedding layer of mortar 15 mm thick Cement plaster with 1:4 mortar for laying floor finishes complete all specified and directed. |
| 25 | M&L for Virified Ceramic tiles light shade 10 mm thick (square/rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all specified and directed. |
| 26 | M & L of Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete complete all specified and directed. |
| 27 | S&F of Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of splain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing with both side Prelam PVC sheet used instead of Plain colour PVC sheet. Stile and rails feathered at edges complete all specified and directed. |
| 28 | S&F of Extruded aluminium alloy handles, fabricated type, anodised with size of handle 150mm long complete all specified and directed. |
| 29 | S&F 200 mm long Aluminium anodised, barrel tower bolts of ex-truded section and fixed complete all as specified and directed. |
| 30 | S&F 250mm long aluminum alloy, anodised sliding bolt with hasp stable bolt type stove enameled black, with bright bolt not less than 12mm dia and including a minimum 06 Nos bolts and nutls. Complete all as specified and directed. |
| 31 | S & F Continuous (piano) hinges, mild steel, bright finish or electrogalvanised. |
| 32 | S&F of Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing with single side prelam PVC sheet used instead of Plain colour PVC sheet & edges will be painted to match with prelam sheet complete all specified and directed by E/I. |
| 33 | M&L two coat oil bound distemper and preparation of newly plastered surface of wall for internal side ceiling complete all specified and directed by E/I. MAKE- APEX |
| 34 | M&L for cement paint i.e. two coat of exterior emulson paint and preparation of newly plastered surface outside complete all specified and directed by E/I. |
| 35 | M&L for 3mm thick wall care putty on wall |
| 36 | M&L for Preparation of New steel and iron surface of any description, over 10cm in width or girth and apply two coat of synthetic enamel paint over coat of red oxide primer complete all specified and directed. |
| 37 | S&F of Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match. |
| 38 | S&F of Glazed ceramic coloured tiles tiles in vertical surface 350x 250x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match. |
| 39 | Plumbing work |
| 40 | S&F of 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed by E/I |
| 41 | S&F of 75mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed by E/I |
| 42 | S&F of 110mm dia PVC (SWR) bends any radius |
| 43 | S&F of 75mm dia PVC (SWR) bends any radius |
| 44 | S&F of PVC (SWR) vent cowl bore in 110mm |
| 45 | S&F of 110mm bore in PVC (SWR) couplers |
| 46 | S&F of 75mm bore in PVC (SWR) couplers |
| 47 | S&F of 110mm PVC (SWR) WC connector with lip ring |
| 48 | S&F of 110mm PVC (SWR) 'P’ trap |
| 49 | S&F of Bottle trap of PTMT having minimum water seal of 25mm .(Minimum weight 32mm-260gms/ 40mm-270 gms) |
| 50 | S&F of PVC (SWR) floor trap, plain with grating including jointing with solvent cement with 75mm dia |
| 51 | S&F of sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x160mm complete all as specified and directed by E/I |
| 52 | S&F of Vitreous China, semi-pedestal pattern (Anglo-Indian Type) including 10 litres, cast iron, valveless. syphonic action type, flushing cistern, high level, with inlet, ball valve, float, chain and pull, and brackets complete all as specified and directed by E/I |
| 53 | Supplying and laying of 16mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 54 | Supplying and laying of 20mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 55 | Supplying and laying of 25mm dia CPVC pipes CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 56 | S&F of 500 liter Rotational moulded polye thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed by E/I |
| 57 | S&F of 15mm dia Plug type bib taps, cast iron, screwed for iron pipe and fixed complete all as specified and directed by E/I . |
| 58 | S&F of 15mm dia Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts,screwed for iron pipe and fixed complete all as specified and directed by E/I . |
| 59 | S&F of 25mm dia Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by E/I . |
| 60 | S&F of 15mm dia Angle stop valve of PTMT any colour high pressure screwed for iron pipe and fixed with Minimum weight 15mm-90gms) complete all as specified and directed by E/I . |
| 61 | S&F of Shower arm 15 mm size, 195mm long with bend of 45degree with flange of PTMT any colour with Minimum weight 40gms complete all as specified and directed by E/I . |
| 62 | S&F of Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats with Minimum weight 300gms complete all as specified and directed by E/I . |
| 63 | S&F of Liquid soap container of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats with Minimum weight 105gms complete all as specified and directed by E/I . |
| 64 | M & L of 100mm with Cement concrete 1:3:6 type C-2 Concrete bed to drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested complete all as specified and directed by E/I . |
| 65 | S&F of precast cement concrete Type B1 1:2:4 (20mm graded aggregate) cover slabs (for man holes etc.) jointed in cement mortar 1:6 etc . complete in all respect as specified. |
| 66 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out Soft/loose soil. |
| 67 | Supply & Spreading Hardcore Broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete in all respect as specified |
| 68 | M&L for 75 mm thick Cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) for c.c. flooring complete all specified and directed. |
| 69 | 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers |
| 70 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. |
| 71 | Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length. |
| 72 | Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion elded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Three track three panels sliding door with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, zinc alloy (zamak) powder coated handle on two panels along with multi-point locking system, adjustable nylon rollers with SS 304 body. Using R3 series with frame (98 mm & above) x (40 mm & above) & sash (30 mm & above) x (74 mm & above). (Height upto 2.5 metre). |
| 73 | Three track three panels sliding window including grill, two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R2 series with frame (70 mm & above) x (40 mm & above) & both glazed and fly screen sash (25 mm & above) x (50 mm & above) with zinc alloy (zamak) powder coated touch locks with hook. (Height upto 1.2 metre). |
| 74 | Providing and fixing false ceiling at all heights including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, 12.5 mm thick tapered edge gypsum moisture resistant board |
| 75 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”: 22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 76 | Excavation in trenches n.exc. 1.50 m deep and not exceeding 1.5 m wide in soft loose soil all as per direction of Engineer inCharge. |
| 77 | Material and labour P.C.C. 1:5:10 as infoundation and sub base of floor as per direction of Engineer in Charge |
| 78 | Material and labour of sub class ‘B’ bricks incement mortar 1:4 as in wall all as per direction of Engineer in Charge |
| 79 | Material and labour in cement mortar rendering 15 mm thick in CM 1:4 finished fair and smooth all as per direction ofEngineer in Charge |
| 80 | Returning filling the soil in layers 25 cm thick, watering, ramming, levelling all as per direction of Engineer in Charge |
| 81 | Removing the soil to a distance of 50 meter all as per direction of Engg in Charge |
| 82 | Use and waste the form work of column and column footing as per direction of Engineerin Charge |
| 83 | Material and labour R.C.C. M-25 as in column footing and column all as per direction of Engineer in Charge. |
| 84 | Supply and fix mild steel reinforcement TMT bar 10# and over, cut to length, bent toshape all as directed |
| 85 | Do – but 8 mm Ø as in stirrups all as perdirection of Engineer in Charge |
| 86 | Do – but 8 mm Ø as in stirrups all as perdirection of Engineer in Charge |
| 87 | Material and labour 60 mm thick interlocking paver block M-35 as in floor on Ganga sand 50 mm cushion |
| 88 | Supply only Ganga sand as for floor as perdirection of EIC |
| 89 | Material and labour of PCC 1:2:4 type B1 as in bed block and coping etc all as perdirection of Engineer in Charge |
| 90 | Supply and mild steel work as in hold fast / anchor bolt as per direction of Engineer in Charge |
| 91 | Supply and fix mild steel tube as in structure of truss and stanchion as perdirection of Engineer in Charge |
| 92 | Supply and fix 10 mm thick double layer poly carbonate sheet as per direction ofEngineer in Charge |
| 93 | Material and labour for two coat painting over a coat of primer over newly prepared steel surface all as per direction of Engineerin Charge |
| 94 | Material and labour for 20 mm thick granitestone flooring including polishing as per direction of Engg in Charge |
| 95 | Material and labour for painting two coat Apex Ultima on a coat of primer over newly prepared surface plastered all as perdirection of Engineer in Charge |
| 96 | Taking down existing treatment any type/ any thicknwss on roof including taking down/ removing the backing bed concrete if any and dispose off at a distance exc 100m as directed and cleaning/ brushing the old roof treatment from the roof of bed complete all as specified and directed byEngr-in-charge. |
| 97 | Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed byEngr-in-charge |
| 98 | Rendering 10mm thick on fair faces of concrete surfaces in cement mortar 1:4, mixed with liquid water proofing compound finished even and smooth without using extra cement . (Liquid water proofing compound to be measured paid separately) complete all as specified anddirected by Engr-in-charAE. |
| 99 | M&L for roof treatment with polymeric water proofing membrane consisting of following complete all as specified and directed:- (a) Applying bituminous grade 85/25 primer conforming to IS 702-1988 @ 1.20 Kgs/Sqm (b) APP modifiedd bitumenous membrane minimum weight 3 Kg/Sqm and minimum 3 mm thick reinforced with polyester non wove fabric( wt not less than 150 gms/Sqm) laid on primed surface by heat process, over laps of 100 mm shall be sealed/fused by flame torch application as per manufacturer instruction. (c) applying two coats of bitumen based @ 0.20 Kgs/Sqm aluminium painting on water proofingtreatment complete all as specified and directed by Engr-in-charAE. |
| 100 | Taking down cement plaster or cement lime plaster on PCC/stone surface/brick surfaces including raking out joints hacking for key scrubbing down with water etc, complete all as specified anddirected by Engr-in-charAE. |
| 101 | M&L for 15mm thick rendering in CM 1:4 with on fair surfaces of walls finished even and smooth without using extra cement complete all as specified anddirected by Engr-in-charAE. |
| 102 | M&L PCC 1:2:4 Type B-1 using 20mm graded stone aggreAEas in roof benching and coping etc rounded or chamfered on edgs, smooth surface complete all asspecified and directed by Engr-in-charAE |
| 103 | M&L RCC M-25 as in columm footing, column, beam etc. |
| 104 | Supply and fixing Mild steel TMT Bar 10 mm and over as in reinformcement. |
| 105 | Supply and fixing Mild steel TMT Bar 8 mm and over as in reinformcement. |
| 106 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but notbacking) and rubbish off the premises, complete all as specified and as directed. |
| 107 | S&F vitrified ceramic tiles dark/light shade digital tiles/(double charAEd) of size 1200 x 600 mm x 10mm thick (square/ rectanglar) polished , in floors etc. laid over 15mm thick screed bed 1:6, set and jointed in neat cement slurry and pointed in white/coloured cement to match complete all as specified and as directed. Make :Somany,/Johnson/Kajaria |
| 108 | M&L Glazed ceramic tiles (coloured) in vertical surfaces 600x300x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to matchover 10mm thick rendering incement mortar 1:3 complete all as specified and as directed. |
| 109 | M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sandmortar 1:6 complete all as specified and as directed. |
| 110 | M&L PCC 40 mm thick 1:2:4 of type B0 using 12.5mm graded stone aggregate as in base of floors complete all as specifiedand as directed. |
| 111 | S&F Vitreous china wash down water closet pan (pedestal pattern) white (excluding fixing bolts flushing cistern and flush pipe ). and trap including connection to drain (or out going pipe) and to flushing pipe anti sphonaAEpipe etc complete including flush pipes and all joints add if fixed in repairs complete all as specified and as directed. Make:Cera/Periware/Hindware |
| 112 | S&F Plastic water closet seat cover coloured/white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and asdirected. |
| 113 | S&F Vitreous Wash Basin of size 450 x 350 in size fancy type premium quality including 32mm dia waste coupling and waste pipe complete with fixing withbracket, etc complete all as specified and directed. Make- Cera/ Periware/Hindware |
| 114 | S&F Vitreous china squatting pan Orissa pattern size 580x440 mm white with P or S trap front or back inlet with integral foot rests (excluding flushing cistern and flush pipe ) complete including provision of lime concrete bedding add if fixed in repair complete all as specified and as directed.Make - Parry ware/Slimline/ Cera |
| 115 | S&F 10 Litres capacity PVC valveless syphonic action type flushing cistern low level, white with inlet ball valve float and handle including brackets connection to pipes and fixing of lever if any joint between flushing pipe and socket of WC pan pre-made complete all as specified and directed. Make : Parry ware/Slimline/Cera |
| 116 | S&F 15mm dia fancy type chromium plated bib taps cast copper alloy with crutch or butterfly handle, scresed down screwed for iron pipe or for brass ferrule and fixed both ends for iron pipe or for unions complete all as specified and asdirected. |
| 117 | S&F PVC connection of 15 mm bore 600 mm long with brass coupling on both ends of superior quality all as specified.PTMT nuts fixed as in repaircomplete all as specified and as directed. |
| 118 | Supplying and laying of 16 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all asspecified and as directed.. |
| 119 | Supplying and laying of 25 mm CPVC pipes SDR 11 & Plain CPVC SDR 11fittings in trenches complete all as specified and as directed. |
| 120 | Supplying and laying of 32 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all asspecified and as directed. |
| 121 | S&F for in repair three layer rotational moulded polyethylene water storaAEtank of capacity 1000 ltrs cylindrical hoisted & fixed in position including dismantiling old water tank complete all as specifed andas directed. |
| 122 | S&F in repair 20 mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod and high density Plastic ball Screwed for iron pipe and fixed (Minimum weight -210 gms complete all as specified and as directed. MakePrayag/Polytuff |
| 123 | S&F in repair 32 mm Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specifiedand as directed. Make Prayag/Polytuff |
| 124 | S&F in repair 15 mm dia Pillar tap cast copper alloy chromium plated fancy type with capstan head and cup screwed down screwed for G I pipe or for brass ferrulecomplete all as specified and as directed. |
| 125 | S&F in repairs 32 mm dia Waste coupling of PTMT (half or full threaded) . (Minimum weight 32mm 45gms/40mm-60 gms)complete all as specified and as directed. |
| 126 | S&F in repairs 32mm dia PVC waste pipe approx 900mm long for sink/WHBcomplete all as specified and as directed. |
| 127 | S&F in repair health feucet to EWC CP brass with minimum 1500mm long CP flexible pipe connection etc, complete all as speicified and as directed. Make : Parryware Cat No T9940A1 or equvailent. |
| 128 | S&F in repairs 15mm dia CP two way tap consisting angle valve to control watersuitable for jet cleaner all as specified and directed. Make: Jaguar /ESS-ESS/Prayag |
| 129 | S&F 600 mmx450x5 mm bevelled edAEmirror of selected quality glass mounted on 6.0 mm thick AC building board or commercial plywood and fixed wooden plug with chromium coated brass screwsand cup washers complete all as specified and as directed. |
| 130 | M&L for complete removal of existing treatment by scrapping with Trucare Wall Sander etc. by skilled labour and make smooth with motorized sanding machine. by skilled labour complete all as specifiedand as directed. |
| 131 | M&L for painting on two coat plastic emulsion paint over a coat of primer and over a coat of Birla putty complete all asspecified and as directed. |
| 132 | M&L for two coat of paint over a coat of primer over old existing surface by Apex altima paint complete all as specified andas directed. |
| 133 | Excavation in trenches not exc 1.5 mtr wide & not exc. 1.5mtr depth for foundation, manholes etc and AEtting out soft/loose soil complete all as specifiedand as directed by Engr-in-charAE. |
| 134 | M & L PCC 1:4:8 type D2 (using 40 mmgraded stone aggregate) as in foundation or mass concrete etc complete all as specified and as directed. |
| 135 | M&L for brick work with Modular fly ash bricks, straight or curved on plan to any radius, built in cement mortar 1:4complete all as specified and directed. |
| 136 | Returning filling in cluding spreading levelling watering and well ramming inlayers not exc 25cm in hard dense soil complete all as specified and as directed. |
| 137 | Removing excavated material exc. 250 m but n exc. 500 m and depositing where directed complete all as specified and asdirected. |
| 138 | M&L 15mm thick rendering in (CM) 1:4 on fair surfaces of brick walls finished even and smooth without using extra cement complete all as specified and as directedby Engr-in-charAE. |
| 139 | M&L preparation of new plastered surfaces of walls and applying two coats of cement base paint over one coat of primer complete all as specified anddirected. |
| 140 | M&L TMT 10mm dia and over cut to length, bent to shape required incl. cranking, bending and incl. mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all asdirected. |
| 141 | S&F M.S framed work such as gate with hold fast handle and locking arranAEment etc complete all as specified and asdirected. |
| 142 | S&F Sign Board with writing work and glow sign light of 4 Nos 20W each including Aluminium frame complete allas specified and as directed. |
| 143 | M&L for preparation of new steel and iron surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of redoxide primer all as apecified and directed |
| 144 | Taking Down the wooden chowkhat including shutter Exc. 1.50 SQM N.Exc.4.00 SQM complete all as specified and as directed. |
| 145 | M&L 2nd class hard wood as in wooden frame for doors with one or more rebates including necessary fixing lugs, hinAEs, lock strike plate, etc including filling cement concrete type C-1 (1:3:6) filling and compaction in frame complete all asspecified and as directed. |
| 146 | Supply and fixe 40 mm Thick flush Shutter as in Door Solid core Construction with block Board plywood Face panels commercial type, both faces are covered with decorative face veneer lamination with lipping/ frame as approved to match complete all asspecified and directed. |
| 147 | M&L for cutting Holes in Brick Wall in cement Mortar for inserting Hold fast and making good in cement mortar 1:3 Exc. Half brick N.exc one brick complete all asspecified and directed by Engr-in-charAE. |
| 148 | M&L PCC 1:2:4 Type B-1 as in bed blockfor fixing hold fast complete all as specified and directed. |
| 149 | S&F Hold fast as in M.S. for frame fixed to frame and bed clock complete all asspecified and directed. |
| 150 | S&F Mild steel hinAE150mm Size heavy quality fixed to frame of wood withnecessary s.s. screw complete all as specified and directed by Engr-in-charAE. |
| 151 | S&F Mild Steel hinAE75mm Size heavyquality fixed to frame of wood with necessary s.s. screw complete all asspecified and directed by Engr-in-charAE. |
| 152 | S&F 2nd class H.W. as in cleat / stopperfor door shutter complete all as specified and directed. |
| 153 | S&F 150mm Size alluminium towe bolt fixed to door shutter with necessary screw complete all as specified and directed byEngr-in-charAE. |
| 154 | S&F Alluminium 300 mm size sliding bolt with hook fixed to door shutter withnecessary screw complete all as specified and directed by Engr-in-charAE. |
| 155 | M&L Two coat Paint over a coat of primer on prepaired wooden surface over new surface by Apex altima paint complete allas specified and as directed. |
| 156 | Surface dressing and exceeding 15 cm deep and getting out insoft/loose soil complete all as specified and directed. |
| 157 | Add or deduct for each 3 cm thickness or part over and above 15 c m a v e r a g e d e p t hcomplete all as specified and directed. |
| 158 | Excavation over areas n. exc1.50 m deep and getting out in soft/loose soil complete all as specified and directed. |
| 159 | Excavating in trenches not exc1.5m wide and n.exc 1.5 m in depth, for foundations, laying of pipes & cable etc and not exceeding 10 square meter on plan for manholes etc and not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 160 | Returning filling in with ap- proved excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed. |
| 161 | Removing excavated material (soils) to a distance n.exc 50 m and depositing where directed at a level not exc 1.50 m above the starting point complete all as specified and directed. |
| 162 | Internal Water Supply |
| 163 | S&F of 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed by E/I |
| 164 | S&F of 75mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed by E/I |
| 165 | S&F of 110mm dia PVC (SWR) bends any radius |
| 166 | S&F of 75mm dia PVC (SWR) bends any radius |
| 167 | S&F of PVC (SWR) vent cowl bore in 110mm |
| 168 | S&F of 110mm bore in PVC (SWR) couplers |
| 169 | S&F of 75mm bore in PVC (SWR) couplers |
| 170 | S&F of 110mm PVC (SWR) WC connector with lip ring |
| 171 | S&F of 110mm PVC (SWR) 'P’ trap |
| 172 | S&F of Bottle trap of PTMT having minimum water seal of 25mm.(Minimum weight 32mm-260gms/ 40mm-270 gms) |
| 173 | S&F of PVC (SWR) floor trap, plain withgrating including jointing with solvent cement with 75mm dia |
| 174 | S&F of Vitreous China, semi- pedestal pattern (Anglo-Indian Type) including 10 litres, cast iron, valveless. syphonic action type, flushing cistern, high level, with inlet, ball valve, float, chain and pull, and brackets complete all as specified and directed by E/I |
| 175 | Supplying and laying of 16mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 176 | Supplying and laying of 25mm dia CPVC pipes CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 177 | S&F of 500 liter Rotational moulded polye thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified and directed by E/I |
| 178 | S&F of 15mm dia Plug type bib taps, cast iron, screwed for iron pipe and fixed complete all as specified and directed by E/I . |
| 179 | S&F of 15mm dia Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly- nuts,screwed for iron pipe and fixed complete all as specified and directed by E/I . |
| 180 | S&F of 25mm dia Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed by E/L . |
| 181 | S&F of 15mm dia Angle stop valve of PTMT any colour high pressure screwed for iron pipe and fixed with Minimum weight15mm-90gms) complete all as specified and directed by E/I . |
| 182 | S&F of Shower arm 15 mm size, 195mm long with bend of 45degree with flanAEof PTMT any colour with Minimum weight 40gms complete all as specified anddirected by E/I . |
| 183 | S&F of Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats with Minimum weight 300gms complete all as specified and directed by E/I . |
| 184 | S&F of Liquid soap container of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats with Minimum weight 105gms complete all as specified and directed by E/I . |
| 185 | M & L of 100mm with Cement concrete 1:3:6 type C-2 Concrete bed to drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested complete all as specified and directed by E/I . |
| 186 | Road, Path and Culvert |
| 187 | M&L for Hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface |
| 188 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing andsweeping extra sand |
| 189 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing andsweeping extra sand. |
| 190 | M&L for PCC 1:2:4 Type B-1 as in Benching Coping etc. |
| 191 | Removing excavate material Not exceeding 50 M and depositing where directed at a Level N exceeding 1.50 M above the starting point |
| 192 | Drainage Work |
| 193 | Laying PCC 40 mm stone aggregate 1:4:8 type D-2 For Base of foundation |
| 194 | Material and Labour Brick work in Sub class B bricks in CM 1:4 as in Wall |
| 195 | Material and Labour PCC as in 1:3:6 Type C 1 in Coping and Benching and channel finished Fair |
| 196 | Material and Labour PCC as in 1:3:6 Type C 1 in Coping and Benching and channel finished Fair |
| 197 | Material and Labour Precast cement concrete 1:2:4 type B-0 as in cover slab for Drain set in cm 1:4 |
| 198 | Supply and Fixed reinforcement TMT Bar As in cover slab binding with wire 10mm dia and over |
| 199 | Removal of soil to a Distance N.EXC. 50 mtrs. Distance. |
| 200 | Earth work |
| 201 | Surface dressing and exceeding 15 cm deep and getting out insoft/loose soil complete all as specified and directed. |
| 202 | Add or deduct for each 3 cm thickness or part over and above 15 c m a v e r a g e d e p t hcomplete all as specified and directed. |
| 203 | Excavation over areas n. exc1.50 m deep and getting out in soft/loose soil complete all as specified and directed. |
| 204 | Excavating in trenches not exc1.5m wide and n.exc 1.5 m in depth, for foundations, laying of pipes & cable etc and not exceeding 10 square meter on plan for manholes etc and not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 205 | Returning filling in with ap- proved excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed. |
| 206 | Removing excavated material (soils) to a distance n.exc 50 m and depositing where directed at a level not exc 1.50 m above the starting point complete all as specified and directed. |
| 207 | Sewage Work |
| 208 | Do – But Exceeding depth 1.50m depthand not excluding 3.00 Mts. |
| 209 | Laying PCC 1:4:8 type D-2 As in foundation & Bedding/ Haunching ofSewer Line. |
| 210 | Material and Labour Brick Work in SubClass ‘B’ Bricks in cement Mortar 1:4 |
| 211 | Supplying and Laying DWC Sewer150mm dia Sewer Pipe with joints |
| 212 | M&L 1:2:4 as in benching and moulding20mm graded stone Aggregate |
| 213 | M&L Rendering 15mm thick in CM 1:4 finished on fairface of brick masonary of concrete surfaces finished even andsmooth without using extra Cement. |
| 214 | Use and Waste of Form Work to soffit of Suspended slab such as Roof Slab, Floor Slabs, landing and similar work not Exceeding 200mm thick (Horizontal and Sloping ), flat and fairfinished |
| 215 | M & L TMT 10mm dia and over cut to length bent to shape required including cranking , bending and including mild steel wire Annealed not less than 0.90mm dia or securingwith clips. |
| 216 | M & L for Reinforced Concrete 1:1.5:3 (Nominal mix) using 20mm graded Stone Aggregate as in slabs supported on Walls, Beams, Columns etc complete allas specified. |
| 217 | M&L RCC 1:2:4 type B1 using 20mm graded stone Aggregate as in precast Manhole Cover and Cover slab of Septic tank and including necessary forms and moulds etc and set in Cement Mortar 1:6 and including demolition ofold slab complete all as specified |
| 218 | Returning filling the soil in the trenches in layer and exceeding 15cm watering compection complete |
| 219 | Removal of soil to a distance exceeding 50 mts and not exceeding 500 mts. |
| 220 | Connection of Sewer Line to a add. Existing manhole making the benching channel and repair complete to match the old |
| 221 | Boundary wall and Gate |
| 222 | Material and Labour Laying PCC in foundation as in concrete 1:4:8 With 40mm stone agg. |
| 223 | Use and waste of Form work for Column footing, Column Beam including necessary scaffolding and support complete |
| 224 | Supply and Fixes steel reinforcement 10mm Dia and over cut to length bent to shape including cracking, binding with 0.9mm diaannealed wire. |
| 225 | Supply and Fixes steel reinforcement 10mm Dia and over cut to length bent to shape including cracking, binding with 8mm dia as in stirups. |
| 226 | Material and labour R.C.C. 1:1.5:3 as in column footing , column beam etc. including properfinish. |
| 227 | Material and labour Brick Work in CementMortar 1:6 with Sub Class ‘B’ b ricks |
| 228 | Material and labour Plaster 15mm thick in Cement Mortar 1:4 finished fair and smooth. |
| 229 | Material and labour P.C.C. 1:2:4 type B-1 as in Coping and Bed Block etc. |
| 230 | Supply & Fixed Mild steel post as in Post fixed top to Boundary wall |
| 231 | Material & Labour two coat exterior ultima paint over plaster surfaces over a coat of primer over prepared steel surfaces. |
| 232 | Material & Labour two coat Synthetic enamel paint over a coat of primer |
| 233 | Returning and filling of soil in trenches in layer of 15cm, Watering and Ramming complete |
| 234 | Removing of surplus soil to distance exceeding 50 mts and not exceeding 250 meters |
| 235 | Supply & fixed of galvanised, 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails, |
| 236 | Supply & Fixing Mild Steel work as in Gate including fixing complete |
| 237 | Supply & Fixing Sign Board with LED Light, Writing Work, School Logo 6000mm 1200mm in Size With necessary Electric wiring and Switch, Erection onTop of Gate Complete. |
| 238 | External Electrification |
| 239 | Supply, design, installation, testing, and commissioning of factory-made, powder-coated, CPRI-approved outdoor LT Feeder Pillar Panel with canopy, dust- and vermin-proof, made of 3 mm thick CRCA steel sheet of suitable size with 50x50x6 mm angle iron frame, powder-coated over red-oxide primer, including grouting in PCC M10 with 20 mm graded stone aggregate 45 cm above ground, complete with internal wiring using suitably sized PVC-insulated, single-core FRLSH copper cables, duly numbered with circuit tags, hinged double-door shutters (front and rear), cubical-type locking arrangement, and slanted roof, including dismantling of existing LT panel and proper connection of incoming and outgoing cables, complete as per SSR Part I, Clause 19.21, and as directed by the Engineer-in-Charge.INCOMING:MCCB, AC 415 V, 125 A, 4-pole, 35/36 kA breaking capacity, fixed TM range, IS13947-II compliant, with busbar connections - 1 No.Aluminium busbar, 250 A capacity, with heat-shrinkable sleeves, mounted on DMC post insulators, 1100 V grade - 4 Nos.Digital voltmeter, 100x100 mm, 0-500 V, flush-mounted with selector switch (Make: AE / L&T / C&S) - 1 set.Digital ammeter, 100x100 mm, flush-mounted, with suitable CTs and selector switch (Make: AE / L&T / C&S) - 1 set.Phase indicator (RYB) LED lamps - 1 set. OUTGOING:MCCB, AC 415 V, 63 A, 4-pole, 16 kA breaking capacity, adjustable type, IS13947-II compliant, with busbar connections (Make: C&S / Havells / Indoasian / L&T / Legrand) - 4 Nos. |
| 240 | Supply, laying, fixing, jointing, testing, and commissioning of LT underground electric power cable, cross-linked polyethylene (XLPE) insulated, galvanised steel strip or wire armoured/PVC insulated, ISI 7098 marked, aluminium conductor, multi-stranded, heavy-duty, 1100 V grade complete, laid in trenches, under floors, fixed naked on walls, on poles, in ducts, or in GI pipes, as specified and directed by the Engineer-in-Charge of following size :-a) 50 Sqmm cross sectional area, 3½ Core.(b) 16 Sqmm cross sectional area, 4 Core. |
| 241 | Material and labour for earthing complete with galvanised mild steel earth plate electrode 600 mm × 600 mm × 6mm thick, buried vertically in ground to a depth not less than 2.25 m below ground level, with top edge of plate not less than 1.5 m below normal ground level. Plate to be packed on all sides with charcoal dust mixed with salt to a thickness of 150 mm. GI strip 32×6 mm to be bolted/riveted to plate and connected to equipment, encased in 40 mm dia GI light grade pipe from plate to equipment. Provide 20 mm dia GI pipe as water pipe with test point, GI funnel with wire mesh, PCC 1:2:4 (using 20 mm graded stone) for pit chamber, RCC pit cover 50 mm thick precast 1:2:4 reinforced with MS bars 6 mm dia @100 mm c/c both ways and 10 mm dia lifting handles. Includes excavation, earth work, laying GI pipe in floor/wall and testing on completion. If desired earth resistance is not achieved, earthing to be redone at no extra cost, complete as specified and directed. |
| 242 | Internal Electrification |
| 243 | Taking down carefully copper/ Aluminium main wiring from existing concealed PVC conduit complete and making good disturbed surfaces of wall floor etc and matching with original colour of wall as specified |
| 244 | M&L for point wiring complete for one light/fan/exhaust fan point controlled by one, one way 6 Amp switch with PVC (FRLSH) insulated sheathed multistranded copper conductors of size 1.50 sqmm nominal cross sectional area single core drawn in and including minimum 20mm dia 'medium grade' PVC concealed conduits ISI marked and fittings, including anadised pressed steel concealed terminal switch boxes not less than 1.20 mm thick of reqd size factory made duly painted inside and outside with one coat red oxide primer, 3mm thick plastic laminated bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers complete including 1.50 sqmm nominal cross sectional area PVC (FRLSH) insulated sheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories including cutting chases for concealed piping and making good disturbed surface to match the existing surface compleate all as specified and directed. |
| 245 | M&L for point wiring complete for one light/fan/exhaust fan point controlled by one, two way 6 Amp switch with PVC (FRLSH) insulated sheathed multistranded copper conductors of size 1.50 sqmm nominal cross sectional area single core drawn in and including minimum 20mm dia 'medium grade' PVC concealed conduits ISI marked and fittings, including anadised pressed steel concealed terminal switch boxes not less than 1.20 mm thick of reqd size factory made duly painted inside and outside with one coat red oxide primer, 3mm thick plastic laminated bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers complete including 1.50 sqmm nominal cross sectional area PVC (FRLSH) insulated sheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories including cutting chases for concealed piping and making good disturbed surface to match the existing surface compleate all as specified and directed. |
| 246 | All as per srl item No 1 above but for for 5 pin 6 Amps socket outlet independent board complete all as specified and directed. |
| 247 | All as per srl item No 1(a) above but for for 3 pin 6 Amps socket outlet on the same board with other switch complete all as specified and directed. |
| 248 | All as per srl item No 1 above but for for 6 pin 16 Amps socket outlet point on independent board with cables of size 2.50 Sqmm and green colour earth cable of size 2.50 Sqmm complete all as specified and directed. |
| 249 | S&F switch piano flush type onw way 6 Amps SP 240 volts complete all as specified and directed. |
| 250 | S&F switch piano flush type onw way 16 Amps SP 240 volts complete all as specified and directed. |
| 251 | S&F socket outlet 2 in 1, 3 pin 6 Amps flush type 240 volts complete all as specified and directed. |
| 252 | S&F socket outlet 2 in 1, 6 pin, 6 and 16 Amps flush type 230 volts complete all as specified and directed. |
| 253 | S&F switch piano flush type Two way 16 Amps SP 240 volts complete all as specified and directed. |
| 254 | S&F ceiling rose 65 x 50mm three terminals complete all as specified and directed. |
| 255 | S&F fan regulator, electronic stepped type 5 stage speed regulation, ISI marked complete all as specified and directed. |
| 256 | S&F lamp holder/ batten holder/ angle holder insulated body with bakelite back plate suitable for fittings complete all as specified and directed. |
| 257 | S&F light fitting with energy saving decorative LED batten 20 watt (4 Feet), 230 volts, energy efficient tube light fitting extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronin driver complete with all accessories prewired and including making connections with 3 core twisted flexible copper cable of size 23/.0076 from ceiling rose/ PPVC connector to light fittings complete all as specified and directed. Make-HALONIX Cat part No - HLTLD-04-20-CW / ORIENT Cat part No-LBLN-20-C-AL / Philips Cat part No-BN021C LED22S PSU CW GR |
| 258 | S&F Lamp with LED Lamp 9 watt, 6500 K, 230 volts B-22 Base complete all as specified and directed. Make - Havells/ Philips/ Bajaj |
| 259 | S&F sheeet metal enclosure MCB distribution board, double door with IP-43 protection Triple pole and neutral 240 volts, 4 way, including suitable size copper bus bar and neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces complete all as specified and directed. |
| 260 | S&F sheeet metal enclosure MCB distribution board, double door with IP-43 protection single pole and neutral 240 volts, 12 way, including suitable size copper bus bar and neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces complete all as specified and directed. |
| 261 | S&F MCB TPN 415 volts, 'C' curv of rating 63 Amps with rupturing capacity 10 kA including providing thimble for outgoing cables complete all as specified and directed. |
| 262 | S&F MCB Single pole 240 volts, 'C' curv of rating 6 to 32 Amps with rupturing capacity 10 kA including providing thimble for outgoing cables complete all as specified and directed. |
| 263 | S&F MCB SPN 240 volts, 'C' curv of rating 6 to 32 Amps with rupturing capacity 10 kA including providing thimble for outgoing cables complete all as specified and directed. |
| 264 | Supply and fixing BLDC 5 star ceiling fan 1200 mm sweep with remote suitable to work on single phase AC 230 Volts 50 Hz complete with connecting electrically to ceiling rose or connector block using PVC insulated and over all shethed 3 core cable of size 0.75 sqmm with flexible copper cable all as required at site complete all as specifed and directed. |
| 265 | Supply and fixing air Ventillating fan 300 mm dia metalic body heavy duty single phase 230 Volts 2200 RPM including fixing and connecting the fan with 3 core PVC insulated and over all sheathed flexible copper conductor cable from ceiling rose / PVC connector block to exhaust fan including making suitable hole in wall and make good disturbed surface of wall including louvers of suitable size and fastener, nut bolts etc all as required at site complete all as specifed and directed. |
| 266 | S&F sub main wiring with two single core PVC insulted (FRLS) unsheathed multistranded copper conductor of size 6 sqmm nominal cross sectional area and one run of 6 sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continious earth wire drawn in and including not less than 20 mm dia 'medium grade' PVC concealed conduits (ISI marked) and fitting including cutting chases to walls from laying conduit and making good the disturbed wall surface to match with existing specification complete all as specified and directed. |
| 267 | M&L earthing complete with galvanised mild steel earth plate electrode 60 x 60 cm x 6mm thick, burried directly in ground vertically to a depth not less than 2.25 mtr below ground level, with top edge of earth plate not less than 1.5 m below normal ground level, connected to galvanised earth lead wire 4 mm dia by means of bolts, check nuts and washers of galvanised iron or steel earth plate shall be packed on all side with charcoal dust mixed with salt to a thickness of 150 mm, galvanised earth lead wire 4 mm dia bolted or riveted to earth plate on one end and connected to equipments on another end. GI earth wire encased in and including 15 mm dia GI light grade pipe from upper end of earth plate upto equipments, 20 mm dia bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, test point, GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in pit chamber and RCC pit over 50 mm thick precast RCC 1:2:4 type B1, duly reinforced with MS round bars 6 mm dia @ 100 c/c both ways with 10 mm dia MS round bar as in lifted handles, excavation, earth work including laying the GI pipe concealed in floor/ wall all as described in electric plate of MES SSR part I complete all as specified and directed and testing on completion. Note:- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. |
| 268 | Internal Electrification |
| 269 | M&L for point wiring complete for one light/fan/exhaust fan point controlled by one, one way 6 Amp switch with PVC (FRLSH) insulated sheathed multistranded copper conductors of size 1.50 sqmm nominal cross sectional area single core drawn in and including minimum 20mm dia 'medium grade' PVC concealed conduits ISI marked and fittings, including anadised pressed steel concealed terminal switch boxes not less than 1.20 mm thick of reqd size factory made duly painted inside and outside with one coat red oxide primer, 3mm thick plastic laminated bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers complete including 1.50 sqmm nominal cross sectional area PVC (FRLSH) insulated sheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories including cutting chases for concealed piping and making good disturbed surface to match the existing surface compleate all as specified and directed. |
| 270 | M&L for point wiring complete for one light/fan/exhaust fan point controlled by one, two way 6 Amp switch with PVC (FRLSH) insulated sheathed multistranded copper conductors of size 1.50 sqmm nominal cross sectional area single core drawn in and including minimum 20mm dia 'medium grade' PVC concealed conduits ISI marked and fittings, including anadised pressed steel concealed terminal switch boxes not less than 1.20 mm thick of reqd size factory made duly painted inside and outside with one coat red oxide primer, 3mm thick plastic laminated bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers complete including 1.50 sqmm nominal cross sectional area PVC (FRLSH) insulated sheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories including cutting chases for concealed piping and making good disturbed surface to match the existing surface compleate all as specified and directed. |
| 271 | All as per srl item No 1 above but for for 5 pin 6 Amps socket outlet independent board complete all as specified and directed. |
| 272 | All as per srl item No 1(a) above but for for 3 pin 6 Amps socket outlet on the same board with other switch complete all as specified and directed. |
| 273 | All as per srl item No 1 above but for for 6 pin 16 Amps socket outlet point on independent board with cables of size 2.50 Sqmm and green colour earth cable of size 2.50 Sqmm complete all as specified and directed. |
| 274 | S&F switch piano flush type one way 6 Amps SP 240 volts complete all as specified and directed. |
| 275 | S&F switch piano flush type one way 16 Amps SP 240 volts complete all as specified and directed. |
| 276 | S&F socket outlet 2 in 1, 3 pin 6 Amps flush type 240 volts complete all as specified and directed. |
| 277 | S&F socket outlet 2 in 1, 6 pin, 6 and 16 Amps flush type 230 volts complete all as specified and directed. |
| 278 | S&F switch piano flush type Two way 6 Amps SP 240 volts complete all as specified and directed. |
| 279 | S&F ceiling rose 65 x 50mm three terminals complete all as specified and directed. |
| 280 | S&F fan regulator, electronic stepped type 5 stage speed regulation, ISI marked complete all as specified and directed. |
| 281 | S&F lamp holder/ batten holder/ angle holder insulated body with bakelite back plate suitable for fittings complete all as specified and directed. |
| 282 | &F light fitting with energy saving decorative LED batten 20 watt (4 Feet), 230 volts, energy efficient tube light fitting extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronin driver complete with all accessories prewired and including making connections with 3 core twisted flexible copper cable of size 23/.0076 from ceiling rose/ PPVC connector to light fittings complete all as specified and directed. |
| 283 | S&F Lamp with LED Lamp 9 watt, 6500 K, 230 volts B-22 Base complete all as specified and directed. Make - Havells/ Philips/ Bajaj |
| 284 | S&F sheeet metal enclosure MCB distribution board, double door with IP-43 protection Triple pole and neutral 240 volts, 4 way, including suitable size copper bus bar and neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces complete all as specified and directed. |
| 285 | S&F sheeet metal enclosure MCB distribution board, double door with IP-43 protection single pole and neutral 240 volts, 12 way, including suitable size copper bus bar and neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces complete all as specified and directed. |
| 286 | S&F MCB TPN 415 volts, 'C' curv of rating 63 Amps with rupturing capacity 10 kA including providing thimble for outgoing cables complete all as specified and directed. |
| 287 | S&F MCB Single pole 240 volts, 'C' curv of rating 6 to 32 Amps with rupturing capacity 10 kA including providing thimble for outgoing cables complete all as specified and directed. |
| 288 | S&F MCB SPN 240 volts, 'C' curv of rating 6 to 32 Amps with rupturing capacity 10 kA including providing thimble for outgoing cables complete all as specified and directed. |
| 289 | Supply and fixing BLDC 5 star ceiling fan 1200 mm sweep with remote suitable to work on single phase AC 230 Volts 50 Hz complete with connecting electrically to ceiling rose or connector block using PVC insulated and over all shethed 3 core cable of size 0.75 sqmm with flexible copper cable all as required at site complete all as specifed and directed. |
| 290 | Supply and fixing air Ventillating fan 300 mm dia metalic body heavy duty single phase 230 Volts 2200 RPM including fixing and connecting the fan with 3 core PVC insulated and over all sheathed flexible copper conductor cable from ceiling rose / PVC connector block to exhaust fan including making suitable hole in wall and make good disturbed surface of wall including louvers of suitable size and fastener, nut bolts etc all as required at site complete all as specifed and directed. |
| 291 | S&F sub main wiring with two single core PVC insulted (FRLS) unsheathed multistranded copper conductor of size 6 sqmm nominal cross sectional area and one run of 6 sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continious earth wire drawn in and including not less than 20 mm dia 'medium grade' PVC concealed conduits (ISI marked) and fitting including cutting chases to walls from laying conduit and making good the disturbed wall surface to match with existing specification complete all as specified and directed. |
| 292 | M&L earthing complete with galvanised mild steel earth plate electrode 60 x 60 cm x 6mm thick, burried directly in ground vertically to a depth not less than 2.25 mtr below ground level, with top edge of earth plate not less than 1.5 m below normal ground level, connected to galvanised earth lead wire 4 mm dia by means of bolts, check nuts and washers of galvanised iron or steel earth plate shall be packed on all side with charcoal dust mixed with salt to a thickness of 150 mm, galvanised earth lead wire 4 mm dia bolted or riveted to earth plate on one end and connected to equipments on another end. GI earth wire encased in and including 15 mm dia GI light grade pipe from upper end of earth plate upto equipments, 20 mm dia bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, test point, GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in pit chamber and RCC pit over 50 mm thick precast RCC 1:2:4 type B1, duly reinforced with MS round bars 6 mm dia @ 100 c/c both ways with 10 mm dia MS round bar as in lifted handles, excavation, earth work including laying the GI pipe concealed in floor/ wall all as described in electric plate of MES SSR part I complete all as specified and directed and testing on completion. Note:- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail