| 1 | SCHEDULE 'A' SECTION-I (BUILDING WORKS) as under is not prepriced by MES and Estimated cost indicates 0.00 under Col-5 signifies this fact only |
| 2 | Extn of PP Building by new construction (Single storey) complete all as specified and shown on drawings. |
| 3 | Schedule 'A' Section-II to Section-VIII as under Serial No. 2.01 to 2.07 are prepriced by MES. |
| 4 | Lump sum price worked out by the Contractor for “Site Clearance/Development, Excavation and Earth Work” as listed in Schedule ‘A’ Section-II |
| 5 | Lump sum price worked out by the Contractor for “Internal Water Supply” as listed in Schedule ‘A’ Section-III |
| 6 | Lump sum price worked out by the Contractor for “External Water Supply” as listed in Schedule ‘A’ Section-IV |
| 7 | Lump sum price worked out by the Contractor for “Internal Electrification” as listed in Schedule ‘A’ Section-V |
| 8 | Lump sum price worked out by the Contractor for “External Electrification” as listed in Schedule ‘A’ Section-VI |
| 9 | Lump sum price worked out by the Contractor for “Sewage Disposal” as listed in Schedule ‘A’ Section-VII |
| 10 | Lump sum price worked out by the Contractor for “Air Conditioning” as listed in Schedule ‘A’ Section-VIII |
| 11 | SCHEDULE `A' SECTION - IX (MISC ITEMS) as here-in-after not prepriced by MES (To be quoted by the tenderer against each item) |
| 12 | Internal Electric Supply |
| 13 | Supplying and fixing metal box of size 200 mm X 150 mm X 60 mm deep on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. complete all as specified and directed. |
| 14 | Supplying and fixing metal box of size 200 mm X 250 mm X 75 mm deep on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. complete all as specified and directed. |
| 15 | M&L for Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25mtrs deep below ground level) with top edge of plate not less than 1.5mtrs below normal ground level, connected to GI strip of size 25 x 5 by means of bolts,nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point on completion with and including 40mm bore medium grade GI protection pipe (upto 7.5mtr long) for earth and 20mm GI medium grade for watering including PCC chamber pit & cover with suitable lifting hooks, with funnel, wire mesh, common salt, charcoal filling, necessary excavation and earth work in any type of soil complete all as specified and directed. |
| 16 | Supply & Fix Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fitting with 7W LED lamp complete all as specified and directed. |
| 17 | Supply and fixing RJ11 connector, plug alongwith Telephone Landline Cord Cable of length 03 Mtr with Standard RJ-11 Plugs complete all as specified and directed. |
| 18 | Suppy and fixing of 2 Pair 0.5 mm dia annealed copper conductor, FRLS PVC insulated unarmoured Telephone Cable complete all as specified and directed. |
| 19 | Internal Water Supply |
| 20 | S&F CP brass auto closing urinal valve 15mm bore, fancy type with wall flange and CP connecting pipes complete all as specified and directed. |
| 21 | External Water Supply |
| 22 | Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 complete all as specified and directed. |
| 23 | External Electric Supply |
| 24 | M&L for Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25mtrs deep below ground level) with top edge of plate not less than 1.5mtrs below normal ground level, connected to GI strip of size 32 x 6 by means of bolts,nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point on completion with and including 40mm bore medium grade GI protection pipe (upto 7.5mtr long) for earth and 20mm GI medium grade for watering including PCC chamber pit & cover with suitable lifting hooks, with funnel, wire mesh, common salt, charcoal filling, necessary excavation and earth work in any type of soil complete all as specified and directed. |
| 25 | Supply, install, testing & commissioning of LT control panel board \\"out-door type\\" of size 1500 mm (height) x 1200 mm (breadth) x 500 mm (depth) (minimum dimensions) factory fabricated CPRI approved (type-tested) with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-54, double door, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & tinned copper bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming ACB/MCCB rating. The panel board shall be fabricated out of 3.15 mm thick (for outer portions) & 2.0 mm thick (for inner portions) CRCA sheet duly pre-treated & powder coated, supporting angle iron frame & MC channel base suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable glands of suitable sizes incl suitable PCC (1:3:6) type C-2 foundation, necessary earthwork (if any) complete all as specified & as directed with & incl the following accessories : |
| 26 | BUS-BAR & INTERNAL CONNECTIONS :The bus-bars shall be made up of 04 Nos high grade tinned copper 600 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized \\"F\\" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc.PROVISION FOR CABLE ENTRY :The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables with the help of glands matching the existing LT cable sizes.INCOMING :(a) MCCB 4P (Ics = 100% Icu) with adjustable short circuit & adjustable overload setting, suitable for isolation, inbuilt instantaneous protection, having breaking capacity 36 KA & of rating 400 A - 01 Nos. OUTGOINGS :(a) MCCB 3P (Ics = 100% Icu) with thermal magnetic release having breaking capacity 25 KA & of rating 250 A - 06 Nos .(b) MCCB 3P (Ics = 100% Icu) with thermal magnetic release, having breaking capacity 25 KA & of rating 100 A - 06 Nos .INSTRUMENTATION SYSTEM :(a) Digital type Multi-Function meter with built in selector Switch & 03 Nos CTs matching with the I/C breaker, Accuracy Class - 1, 3 phase, Size 96 x 96 mm.(b) Indicator lamp with integral circuit (230/240V) & cluster LED (Red, Orange, Blue) - 01 Set.(c) Danger notice plate of size 20 x 15 cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventioinal skul and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size - 02 Nos (Front & Back). |
| 27 | Sewage Disposal |
| 28 | M&L for constructing brick masonry manhole using burn clay bricks in cement mortar 1:4 (1 cement: 4 coarse sand) with RCC top slab with 1:1.5:3 mix (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nomincal size), foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement:3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1;2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design of inside size 90 x 80 cm and 45 cm deep including C.I cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 Kg (weight of cover 23 Kg and weight of frame 15 Kg) complete all as specified and directed. |
| 29 | Extra over item No. 8.01 for depth for manholes beyond 45 cm complete all as specified and directed. |
| 30 | On site LLDPE septic tank designed to carry sewage and suflage water, excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc for 30 users complete all as specified and directed. |
| 31 | M&L for constructing soakage wells with excavation in any type of soil, foundation in PCC 1;3:6, wals of honey combed masonry with top ring of M-25/SFRC cover, interconnecting pip of RCC DWC complete filled with brick bats of size 3.00 m dia x 3.00 m effective depth complete all as specified and directed. |
| 32 | Airconditioning |
| 33 | Supply and fix 5 KVA Voltage stabilizer for automatic operation, single phase naturally oil cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy ± 2.5% and speed of correction 50 Volts per second complete all as specified and directed. Please Enable Macros to View BoQ information |